Loading...
HomeMy WebLinkAboutB12-0626 CR1TOWN OF VAIL9 Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two. hour minimum building review fee of $110 will be charged upon reissuance of the permit. Application /Permit #(s) information applies to: Project Street Address: (Number) (Street) (Suite #) Attention isions esponse to Correction Letter _attached copy of correction letter C) Deferred Submittal (0 Other Building /Complex Name: I.ZT-� Description of Transmittal/ List of Changes, Items Attached: Applicant Information (architect, contracto /weer/ ner's.. rep) Contact Name i �G ✓� t� , a1 C-C Address: �� ( S r � //P<V City �� �` State: C� Zip: Contact Name: I�)r. trr/ l�e /� Contact Phone: "( � — '1l y U Contact E -Mail: I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordi nces of the Town applicable thereto. x Owner /Owner's Representative Signature (Required) For Office Use Only: Fee Paid: Received From: Cash Check # OC: Visa / AAC Last 4 CC # exp. date: Authorization # Date Received: JAN 18 zoo TOWN OFVAL (use additional sheet if necessary) Building Permits: Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building: $ Plumbing: $ Electrical: $ Mechanical: $ Total: $ C) Date Received: JAN 18 zoo TOWN OFVAL January 15, 2013 Re- B12 -0626 241 E Meadow Drive To: Town of Vail Building Dept In response to the comment letter from your office dated 12/19/2012— BUILDING COMMENTS rchitectural Comments: 1. Show compliance for accessibility for point of sale per section 1109.11.3 IBC 2009 edition. Response: 1109.11.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. The new yogurt expansion of la cantina is designed to function as an extension of the current restaurant. Signage will direct patrons to the main restaurant counter located in la cantina to serve as the primary point of sale counter for the yogurt operation for 50% of the time. For the other 50% of the time the restaurant counter will serve as the auxiliary counter for handicapped patrons of the yogurt operation and the primary point of sale counter will be the counter closest to the yogurt machines. The restaurant counter ( auxiliary counter ) located at la cantina is handicapped accessible as per the 2010 ADA Standards for Accessible Design section 904.4 Sales and Service Counters. Sales counters and service counters shall comply with 904.4.1 904.4.1 Parallel Approach. A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided. In addition section 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum is a further requirement for accessible counters of which the la cantina counter complies. 2. Please clarify if yogurt dispensers are to be dispensed by the public. If so show how accessibility for reach and maneuvering clearance is obtained. Reference section 1109.12 IBC Response: The yogurt machines will be self serve and in compliance with section 1109.12 Controls, operating mechanisms and hardware. Controls, operating mechanisms and hardware intended for operation by the occupant, including switches that control lighting and ventilation and electrical convenience outlets, in accessible spaces, along accessible routes or as parts of accessible elements shall be accessible. Accessibility is attained through clear ground space in front of the machines and a maximum height for the controls of the machines both of which the yogurt machines achieve as per the 2010 ADA Standards for Accessible Design section 05.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum, and section 308.2 Forward Reach.308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. Plumbing Comments: 1. Provide a complete plumbing plan showing actual location of drains and water piping to include existing sizing. Reference section 106.3.1 IPC 2009 edition. Response: Plumbing plans as per section 106.3.1 are included. 2. Show how drainage is going to an approved grease interceptor as required by section 1003.1 IPC 2009 edition. Include sizing Response: In normal use of the proposed mop sink grease is not commonly present. In those rare instances where a grease spill does occur on the floor and a mop is used to clean up the spill, the grease laden water will be dumped in the restaurant in a receptacle which is connected to the grease trap that currently exists in the restaurant. Therefore a grease trap is not required as per section 1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the building drainage system, the public sewer, the private sewage disposal system or the sewage treatment plant or processes. 3. Plan to reflect compliance for cross connection protection if beverage dispensers to be provided. Reference section 608.16 IPC. Please clarify Response: Coffee machine will have a cold supply line which will be connected to a back flow preventer. 3. Plans to reflect tempered water per section 607.1 IPC Response: A device will be installed to not allow the hot water for the hand sink to be greater than 110 F as per IPC section 607.1 Tempered water shall be supplied through a SECTION 1 SPECIFICATIONS 1.1 DESCRIPTION The Stoelting Endura /Futura 131 counterfreezer is gravity fed. The freezer is equipped with fully automatic controls to provide a uniform product. The freezer is designed to operate with almost any type of commercial soft serve or non -dairy mixes available, including ice milk, ice cream, yogurt, and frozen dietary desserts. The freezer is designed to be used with both barrels in operation. If you desire to use one barrel only, the freezer must be cleaned, sanitized and filled with fresh mix daily. For more information call your authorized Stoelting Serviceperson. This manual is designed to assistqualified service person- nel and operators in the installation, operation and mainte- nance of the Stoelting Model Endura /Futura 131 gravity freezer. Information Packet Location Model Endura /Futura 131 -behind Left Side Panel or behind the Front Decorative Panel. 1.2 SPECIFICATIONS 34: ��t Am Figure 1. Model Endura /Futura 131 Freezer (This freezer is mounted on the optional Floor Stand.) Figure 2. Specifications MODELENDURA /FUTURA 131 COUNTERMODEL GRAVITYFREEZER Dimensions: Freezer: 22" (56 cm) wide x 28" (72 cm) deep x 34.75" (88 cm) high Crated: 28" (71 cm) wide x 35" (89 cm) deep x 38" (96 cm) high Weight: Freezer: 370 lbs. (168 kg) Crated: 450 lbs. (204 kg) Electrical: DESCRIPTION ENDURA 131 FUTURA 131 Voltage AC 1 Ph 208 -230V 1 Ph 208 -230V Total Run Amps 11.0 12.0 Drive Motors 3/4 HP each 3/4 HP each Compressor 9960 BTU 11,800 BTU Use 20 amp HACR circuit breaker. Automatic safeguard circuit built into electronic control - protects major freezer components under normal operating conditions. Cooling Air cooled requires minimum 3" air clearance on right and left hand side. No clearance needed in the rear. Water cooled required 3/8" I.D. water supply line and 3/8" I.D. drain line minimum. Hopper 3 Gallons (11.35 liters) each refrigerated and insulated. January 15, 2013 Re- B12 -0626 241 E Meadow Drive To: Town of Vail Building Dept In response to the comment letter from your office dated 12/19/2012— BUILDING COMMENTS Architectural Comments: 1. Show compliance for accessibility for point of sale per section 1109.11.3 IBC 2009 edition. Response: 1109.11.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. The new yogurt expansion of la cantina is designed to function as an extension of the current restaurant. Signage will direct patrons to the main restaurant counter located in la cantina to serve as the primary point of sale counter for the yogurt operation for 50% of the time. For the other 50% of the time the restaurant counter will serve as the auxiliary counter for handicapped patrons of the yogurt operation and the primary point of sale counter will be the counter closest to the yogurt machines. The restaurant counter ( auxiliary counter ) located at la cantina is handicapped accessible as per the 2010 ADA Standards for Accessible Design section 904.4 Sales and Service Counters. Sales counters and service counters shall comply with 904.4.1 904.4.1 Parallel Approach. A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided. In addition section 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum is a further requirement for accessible counters of which the la cantina counter complies. 2. Please clarify if yogurt dispensers are to be dispensed by the public. If so show how accessibility for reach and maneuvering clearance is obtained. Reference section 1109.12 IBC Response: The yogurt machines will be self serve and in compliance with section 1109.12 Controls, operating mechanisms and hardware. Controls, operating mechanisms and hardware intended for operation by the occupant, including switches that control lighting and ventilation and electrical convenience outlets, in accessible spaces, along accessible routes or as parts of accessible elements shall be accessible. Accessibility is attained through clear ground space in front of the machines and a maximum height for the controls of the machines both of which the yogurt machines achieve as per the 2010 ADA Standards for Accessible Design section 05.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum, and section 308.2 Forward Reach.308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. Plumbing Comments: 1. Provide a complete plumbing plan showing actual location of drains and water piping to include existing sizing. Reference section 106.3.1 IPC 2009 edition. Response: Plumbing plans as per section 106.3.1 are included. 2. Show how drainage is going to an approved grease interceptor as required by section 1003.1 IPC 2009 edition. Include sizing Response: In normal use of the proposed mop sink grease is not commonly present. In those rare instances where a grease spill does occur on the floor and a mop is used to clean up the spill, the grease laden water will be dumped in the restaurant in a receptacle which is connected to the grease trap that currently exists in the restaurant. Therefore a grease trap is not required as per section 1003.1 Where required. Interceptors and separators shall be provided to prevent the discharge of oil, grease, sand and other substances harmful or hazardous to the building drainage system, the public sewer, the private sewage disposal system or the sewage treatment plant or processes. 3. Plan to reflect compliance for cross connection protection if beverage dispensers to be provided. Reference section 608.16 IPC. Please clarify Response: Coffee machine will have a cold supply line which will be connected to a back flow preventer. 3. Plans to reflect tempered water per section 607.1 IPC Response: A device will be installed to not allow the hot water for the hand sink to be greater than 110 F as per IPC section 607.1 Tempered water shall be supplied through a SECTION 1 SPECIFICATIONS 1.1 DESCRIPTION TheStoeltingEndura /Futura 131 counterfreezer is gravity fed. The freezer is equipped with fully automatic controls to provide a uniform product. The freezer is designed to operate with almost any type of commercial soft serve or non -dairy mixes available, including ice milk, ice cream, yogurt, and frozen dietary desserts. The freezer is designed to be used with both barrels in operation. If you desire to use one barrel only, the freezer must be cleaned, sanitized and filled with fresh mix daily. For more information call your authorized Stoelting Serviceperson. This manual is designed to assist qualified service person- nel and operators in the installation, operation and mainte- nance of the Stoelting Model Endura /Futura 131 gravity freezer. Information Packet Location Model Endura /Futura 131 - behind Left Side Panel or behind the Front Decorative Panel. 1.2 SPECIFICATIONS 34: Figure 1. Model Endura /Futura 131 Freezer (This freezer is mounted on the optional Floor Stand.) w.v Figure 2. Specifications MODEL ENDURA /FUTURA 131 COUNTERMODEL GRAVITYFREEZER Dimensions: Freezer: 22" (56 cm) wide x 28" (72 cm) deep x 34.75' (88 cm) high Crated: 28" (71 cm) wide x 35" (89 cm) deep x 38" (96 cm) high Weight: Freezer: 370 lbs. (168 kg) Crated: 450 lbs. (204 kg) Electrical: DESCRIPTION ENDURA 131 FUTURA 131 Voltage AC 1 Ph 208 -230V 1 Ph 208 -230V Total Run Amps 11.0 12.0 Drive Motors 3/4 HP each 3/4 HP each Compressor 9960 BTU 11,800 BTU Use 20 amp HACR circuit breaker. Automatic safeguard circuit built into electronic control -protects major freezer components under normal operating conditions. Cooling Air cooled requires minimum 3" air clearance on right and left hand side. No clearance needed in the rear. Water cooled required 3/8" I.D. water supply line and 3/8" I.D. drain line minimum. Hopper 3 Gallons (11.35 liters) each refrigerated and insulated. 2