HomeMy WebLinkAboutB09-0038 INSPECTIONS03 -07 -2011
4:06 pm
Inspection Request Reporting Page 1
Vail, CO - City Of
Requested Inspect Date:
Inspection Area:
Site Address:
A /P /D Information
Activity: B09 -0038 Type: A -BUILD
Const Type: Occupancy:
Owner: PLZAK, MAXIMILIAN F. &ELIZABETH A. -JT
Contractor: RESIDENTIAL DESIGN GROUP
Description: ADDITION AND REMODEL
Requested Inspection(s)
Item:
Requestor:
Comments:
Assigned To:
Action:
90 BLDG -Final
RESIDENTIAL DESIGN GROUP
331 -5739
JMONDRAGON
A Q
ime Exp
Lv —f
Inspection History
Item: 10
Item: 20
Item: 30
BLDG - FOOTING — Approved **
05/19/09 Inspector: JRM Action: AP APPROVED
Comment:
BLDG - Foundation /Steel ** Approv
05/21/09 Inspector: JRM Action: AP APPROVED
Comment:
BLDG - Framing ** Approved **
09/03/09 Inspector: shahn Action: CR CORRECTION REQUIRED
Comment: INFORMED CONTRACTOR THAT ALARM PERMIT REQUIRED PER VFD.
ILC APPROVAL REQUIRED.
ELECTRIC ROUGH REQUIRED.
HOMEOWNER REQUIRED TO GET PLUMBING AND MECH PERMITS.
09/08/09 Inspector: JRM Action: CR CORRECTION REQUIRED
Comment: ALARM, MECH AND PLMB PERMITS REQUIRED
09/08/09 Inspector: JRM Action: CR CORRECTION REQUIRED
Comment: STRUCTURAL CHANGES HAVE BEEN MADE, 8 1/2 X 11 ADDENDUM MUST BE STAMPED BY
ENGINEER AND NEW STRUCTURAL DRAWING MUST BE COLLATED INTO FILED AND
OFFICE SETS. APPROVED TO START LATHE PROCESS FOR INSPECTION
09/18/09 Inspector: cg Action: COND APPROVED /CONDITIONS
Comment: CHECK FRAMING ITEMS AT INSULATION INSPECTION
11 INSTALL SHEAR WALL BETWEEN GARAGES PER PLAN, STRAP TOP PLATES BACK TO
CMU WALL
2 NAIL PLATES NEEDED CONDUIT IN BEDROOM
3 COMPLETE FURRING STRIPS AT CMU WALLS AT ENTRY
4 DRAFTSTOP ALL TOP PLATES WITH FOAM
5 OBTAIN FIRE ALARM PERMIT AND ROUGH IN INSPECTION IF
NECESSARY FROM FIRE DEPT.
Item: 50 BLDG - Insulation Approved **
10/02/09 Inspector:BW
Comment:
Item: 60 BLDG - Sheetrock Nail Approved **pLEY10/09/09 Inspector:EPEN
Comment:
Item. 70 BLDG -Misc.Approved **
09/18/09 Inspector:cComment:STUCCO LATH
REPT131
Tuesday, March 08, 2011
JRM
740 SANDY LN VAIL
UNIT A
Sub Type: ADUP
Use: IRC
Phone: 970.524.9894
Status: ISSUED
Insp Area: JRM
Requested Time: 09:00 AM
Phone: 970.524.9894
Entered By: JMONDRAGON K
Action: AP APPROVED
Action: AP APPROVED
Action: AP APPROVED
Run Id: 12805
w
11 -03 -2009 Inspection Request
r - n nReporting Page 117.54 am Vnil - ritu
Requested Inspect Date: Tuesday, November 03, 2009
Inspection Area: SH
Site Address: 740 SANDY LN VAIL
UNIT A
A/P /D Information
Activity: E09 -0100 Type: B -ELEC Sub Type: ADUP
Const Type: Occupancy: Use:
Owner: PLZAK, MAXIMILIAN F. &ELIZABETH A. -JT
Contractor: BARE ELECTRICAL CONTRACTING, INC Phone: 970 - 926 -7152
Description: WIRING AND LIGHTING FOR REMODEL
Reauested Insoectionts
Item:
Requestor:
Comments:
Assigned To:
Action:
C
190 ELEC -Final
BARE ELECTRICAL CONTRACTING, INC
471 -6325
MDENNEY
Time Exp:
Status: ISSUED
Insp Area: SH
Requested Time: 08:30 AM
Phone: 970 - 926 -7152
Entered By: MHAEBERLE K
I / / 17
Inspection History
Item:110 ELEC - Service
Item:120 ELEC-Rough Approved **
08/12/09 Inspector: shahn Action: PI PARTIAL INSPECTION
Comment:kitchen rough ok.
08/14/09 Inspector: shahn Action: PI PARTIAL INSPECTION
Comment:2) lower bath ok.
09/10/09 Inspector: MDSAFE Action: AP APPROVED
Comment:ENTRY, GARAGE, HALLWAY, BEDROOMS.
Item:130 ELEC- Conduit
Item:140 ELEC -Misc.
Item:190 ELEC -Final
REPT131 Run Id: 10557