HomeMy WebLinkAboutPRJ08-0394 A09-0072 LEGALOWNER VAIL SPA CONDOMINIUM ASSOC
710 W LIONSHEAD CIR
VAIL
co 816s7
CONTRACTOR SIMPLEX GRTNNELL
6240 SMITH ROAD
DENVER
/rn
License:903-S
Desciption: RELOCATE LOBBY REMOTE ANNUNCIATOR. NO SMOKE OR INTIATING
DEVICE PROCRAMMINC.
Valuation:$680.00
t + +,i r t + r,t t *r r r* '| 'l
TOWN OF VATL FIRE DEPARTMENT
75 S. FRONTAGEROAD
VAIL, CO 8t657
970-479-2135
Electrical----->
DRB Fee----->
lnvestigation:-->
Will Call----->
TOTAL FEES->
I hereby acknowledge that I have
and state that all the information
Town ordinances and state laws,
approved, International Building
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Job Address: 710 W LIONSHEAD CR VAIL
Location.....: VAIL SPA CONDOS
ParcelNo...: 210106317011
ProjectNo (,/LSOZI . O37Ll
Permit #: A09-0072
Status... : ISSUED
Applied..: 10/0212009
Issued..: 10/07/2009
Expires . .: 04/0512010
9144 .00
s0.00
ro / 02/ 2ooe
L0/02/20O9 Phone: 303-355-0500
90.00
50.00
s0.00
Total Calculated Fees->
Addilional F€es------>
Total Permit Fee---->
Payments--------------->
BALANCE DUE_..-.>
l + *+ +*+,t **:3 * * * l t t
Approvals:IICM: O55OO FIRE DEPARTMENT
aO/05/2009 Mccee Act j-on: AP scope letter
CONDITIONS OF APPROVALCond: 52
Monitored fire alarm system required and shall comply with NFPA 72 (20o2 ed. ) and VFES
Standards
+*'l***+i*t*+tt++t
DECLARATIONS
read this application, filled out in full the information required, completed an accurate plot plan,
as required is correct. I agree to comply with the information and plot plan, to comply with all
and to build this structure according to the towns zoning and subdivision codes, design review
and Residential Codes and other of the Town applicable thereto.
2252 FROM 8:00 AM - 5 PM.REQTIf,STS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS tN
CTOR HIMSELF AND OWNER
llttt+**{'+++**f*****t'a!*{'1r**+**+*t**t*f*tttaaaalaftft*t*+at*+* |l * | t**at*lt** *f***t****** *a+*a
TOWNOFVAIL, COLORADO Shtement
aa*ll**+lt*l*laa'l*++*+*r++f *l+*aataaa+la'|**aalaaaal* * * * ** * * *** '} * * | * | ** l*a* * 't **l**aaat *l ** * * |
Statement Number: R090001390 Amount: $144.00 LO/07/2OO908:59 Al,l
Payment Method: Credit Crd
WIIJIJIAI!SON
IniE: SAB
Notation: MC-iIAII{ES
$144.0o
**l**t**i*'l****t*****'|*at*********tr****t**********t********at*'t * *'t**ti*f f *f *ir*****r'**r**f,*r
ACCOI,JNT ITEM LIST:
Account Code CurrenE Pnta
PF 00100003112300 PIJA}I CHECK FEES 144 .00
Perrnit No :
Parcel No:
Site Address :
IJocaE ion:
This Payment:
409 - 0 072
2101- 053 - 1701- 1
710 }I LIONSHEAD
VA,IIJ SPA CONDOS
Deacription
f,141e: ALARI.{ PERIIIIT
CR VATI,
Total Fees:
Total AL}L Pmts:
Balance :
$144.00
$L44 .00
90.00
FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be acceoted without this information.
Project Street Address:'-)t^ | , 2lrt /e,.< -1(lr<
(Number) (Street) / (Suite #)
t/ .,'
Buifding/complex Name: l/y'rz S ?rl
Contractor Injgrnation:
.- ^-^ - ^.,. \,-zllt Ev/t-D.- - t,t/-/1
Office Use:
P.jed#: PRJ o I -OS 3P
BuildingPermit#, AO? -0361'{
Alarm Permit#: A)q '00
Lot #: Block # Subdivision:
companyAddre "t' LZ f a :Ca;rr+,4,1
/41
ciru, ,[L'nt/en- st.n":lO ztp, SiHtl
,/7 ./
Contact Name: Lt2z e:? L/ t-dzzc= i-.1s e 'J
"on"ornon,
47u f5C' rr'b
/ ,.t r"--n---^, , f) 1*o,,-. -- -,,.t--,, F^
Derailed Description ot worx, Z'zrtrt rz' /o a g f
&nri, ilr^t'-c'a*'o . rL)o (norn (It
7 '"ttt=lu /.4tr'r<'"' Ptrt' 'r.t",'n tzi t"u
uI ",i rt.,- lJ-- r; " ?.'n. o,.. n
(use addrtional sheet if necessary)
Town of Vail Co ntractor aegisfrlfidoxbl:fu
Conf6ctor Signature (required)
Does a Fire Alarm Exist? Yes (I) No ( )
Does a Sprinkler System Exist? Yes (l/) No ( )
Work Class:
New( ) Addition ( ) Remodel fi) Repair ( )
Retro-Fit ( ) Other ( )Property Information
Parcel #:
(For parcel #, contact Eagle County Assessors Office at 970-328-8640 or
visit www.eaglecounty.us/patie)
\ /,,.,1 (-
Tenant Name: V dt\ \ ) OO\ 't
Owner Name:
Type of Building:
Single-Family ( ) Duplex( ) Multi-Family ( )
Commercill ( ). Reslaurant( ) otherO, Ur2,:or".,-
Date Received:
Comolele Valuation for Fire Alarm Permit:
f ly,stt'ant* try{ti :
* nlf utv\ftnuc/h'0r +<-2- '
29-May-09
Fire Department Process
For Gommercial & Residential Fire Alarm Systems
Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the
following:
A Colorado Registered Engineer's stamp
Device locations on reflected ceiling plans
Reflected Geiling Plans (RCP)
Typical device wiring diagrams
Battery calculations
Battery calculations
A list of specific device model numbers
Equipment cut sheets of each type of device
The number of each tYPe of device
Information indicating the specific zones
Circuit diagrams
Point to point wiring diagram
Wiring type, size and number of conductors
The source of AC Power circuits
Fire alarm panel locations
Knox Box location
lnformation indicating monitoring method and monitoring agency
Information regarding property managers and contact numbers
Owner's primary residence location and contact numbers
Instructions for fire alarm system operations and any pertinent code numbers for proper opera-
tions
This check list has been provided to ensure that our review process may be handled in a timely manner.
I have read and understand the above listed submittal requirements:
il^ProjecUStreet Address:
Contractor Signature:
Date Signed:
1
rtrw{6"1|ot'{0"' {lt{C\l
4{
29-May49
In order to prevent a non-emergency response from the Vail Fire Department Suppression crews to the con-
struction location you may be working on, we ask that you perform the following tasks:
Fire DePartment Guidelines
For Preventing Non-Emergency Fire Alarms
Determine what kind of fire alarm system exists within the structure you are
working in with the owner or the manager of the property involved or by contact-
ing the Vail Fire Department.
Determine with the owner or manager of the property, which alarm company
services the system for them
Become familiar with the different components that are associated with the fire
alarm system and how they operate before the DEMO begins'
Never paint a smoke detector, thermal detector, or any other component of the
fire alaim system and never paint a sprinkler head'
For larger projects, please contact the Vail Fire Department so that we-can
work wih youin determining what needs to be done to alter or "Zone Out" spe-
cific areas of the alarm system for the structure.
,/
v
l/
Pfease contact the Vail Fire Deparbnent at 479-2252.
I have read and understand the above submittal requirements:
ProjecUStreet Address:
Contractor Signature:
Date Signed:
2 L//*tr=r"
29-May49
Fire Department Guidelines
Pre-Plan Information Sheet
BUILDING INFORMATION:
Building Name:
Street Address & Phone #:
Knox Box Location:
Alarm Panel Location:
Alarm Silence & Rest Codes: 4/
RPS': Names & Phone Numbers (Work & Home)
Owner:
Property Manager:
Property Maintenance Mgr:
Alarm Service CompanY:
BUILDING UTILITIES:
Gas:
Main Location:
Other Locations:
Electric:
Main Location:
Other Locations:
Water:
Main Valve Location:
Main Fire Valve Location:
Secondary Fire Valve Loc:
29-May-09
ttlco
Fire &
Security
9implcxGdnncll
Sinwlox6diltsll LP
6210stfiilt Rd
oaMf',CO
u216
Cell 97G556-7796
Fax:3&2164878
0fi6303"35S0500
E-tlatruifrg/,A,/f€6i,&Fxgit tBl.Nn
Lt. Mike Vaughan
Fire Prevention
Fire Marshall
42 WestMeadowDrive
Vail. CO 81657
October l$,2009
Lt. Mike Vaughan,
This letter is to provide the scope of work for the relocation of the Vail Spa front lobby remote
annunciator.
Scope of Work:
SimplexGrirmell will disconnect the Vail Spa Lobby Remote Annunciator plus program it out of the
FACP so there will not be a touble on the panel during constnrction-
NEDBO construction will be responsible for reinstalling the existing back box and running the existing
wire to the back box. Upon comptetion of construction and the site is clean per NFPA 72 code, then
SimplexGrinnell will reconnect and reprograrn the annunciator back into the FACP.
Andv Polar NICET tr will be the technician on-site. 970-556-0702 cell
Glen Williamson
SimplexGrinnell
Western Slope Mountain Area Sales Rep
NICET II I2IO9O
970-55G7796
gwilliamson@simplexgrinnell.com
Thank yopfor-qll your help,
.,'/-,/.":....., ;.'/ ,/.:-..-- )i'2rl'</a/2
o-
E
,'a|
oz.
+
@N
I
o.
E]
E]
o
M
\/
ffi
I
OO
!i-
o
=
\J
i'.
JF F-
fL
=JJ
r
."$
t*<
artl
-L
<
e
a
ttrt<
{t:
t-(r-
(9
(-,