HomeMy WebLinkAboutA09-0024 plansi ZUG RESIDENCE ZONE LIST DEVICE # DEVICE TYPE LEVEL DESCRIPTION 001 SMOKE DETECTOR LOW ER MECH ROOM AT FACP 002 HEAT DETECTOR LOWER EAST GARAGE 003 HEAT DETECTOR LOWER WEST GARAGE 004 SMOKE DETECTOR LOW ER LOW ER HALLWAY 005 SMOKE DETECTOR LOW ER SOUTH BEDROOM 006 SMOKE DETECTOR LOW ER NORTH BEDROOM 007 HEAT DETECTOR LOW ER LOW ER LAUNDRY 008 SMOKE DETECTOR MAIN PLAYROOM 0�9 SMOKE DETECTOR MAI N NORTHEAST BEDROOM 010 SMOKE DETECTOR MAI N SOUTHEAST BEDROOM 011 HEAT DETECTOR MAIN KITCHEN 012 SMOKE DETECTOR MAIN STAIR LANDING 013 SMOKE DETECTOR MAIN NORTHWEST BEDROOM 014 SMOKE DETECTOR UPPER NORTHEAST BEDROOM 015 SMOKE DETECTOR UPPER SOUTHEAST BEDROOM 016 SMOKE DETECTOR UPPER HALL OUTSIDE BEDROOMS 017 HEAT DETECTOR UPPER UPPER LAUNDRY 018 SMOKE DETECTOR UPPER TOP OF STAIR 0 1 9 S M O K E D E T E C T O R U P P E R W E S T B E D R O O M 020 021 022 023 024 025 THRU 050 Standby Device Type Main FACP CPU W i reless I nterface 4193SN Serial Interface (Heats) 5192SD Smoke Detectors 6160 Keypad SUM COLUMN FOR STANDBY LOAD Alarm Load Device ZUG RESIDENC� Ademco Vista 50 F CF Number of Devices 1 5 14 � 3 Mam FACP CPU Wireless lnterface 4193SN Serial Interface (Heats) 5192SD Smoke Detectors 6139 Keypad MHW Sounder SUM COLUMN FOR STANDBY LOAD Standby Load Current (Amps) Alarm Load i Current (Amps) I Add Standby and Alarm Load for Required Ampere Hour Battery Multiply by the Derating Factor of 1 2 Total Ampere Hours Required BEDROOM c a-0 > � � v \� / ,� � / \ � \ � \ � O �1 \\ /��___ _- � / - RCP FOR RAISEO O�Z \ / CEILING FOUND ON J � / UPPER LEVEL POWER � / 8 ELECTRICAL PLAN \��LIVING ��� . � . � ___ .� �� . � OPEN TO ABOVE ___ � � '. � i �' . � � � . �i � . `� � � BEDROOM i� ,' �. / \ i �� (s-o ) KITCHEN � � \�� �'� �`� _____________________ ? � I I L-FIREPLACE 009 PL/1Y I I CHIMNEY ROOM O 011 W i i 0012 W H ___ FRO�I BELOW �� ce-o� i �� H— i i i i i � c9o?� � i i F� -i- --- � i� ----- i �---------- ` � i i i i BATH � ' i c9-0� ii �� '%� ii ii , � I I OPEN ABOVE ii � � - ------------------ BATH H (90 ) DINING � BEDROOM ( e-o ) � oos W � � G��pS` I I `y�c�� ��o i i �t o`� I� TO ABOVE i \\ � � i I � ( 8 Oi ) CEIIING SLOPE ? i --- O10 � � � BEDROOM i � i MAIN LEVEL FLOOR PLAN � SCALE I/8" = I'-O" NORTII --------------- GARAGE �ao, ` ' 1 \�� % 003W �� i� �� � � � � � � — BATH i i �-_-0 � ? �-_-0 > � � 004 W H KP � � 005 W FACP O BEDROOM 0 1 007W ( e` o ) MECH � 8-0 > LAUNDRY �Y C ____ �`�G �+�� OQ�i ��� LOWER LEVEL FLOOR PLAN � SCALE I/8" = I'-O" NORTh --------------- GARAGE cBO > _ TO ABOVE ii ii �� � Y --- I STORAGE c e-o', 002 (BA ) II II ii BOILER Number of Devices Current Total Current Am s Am s X 0 032 = 0 032 X 0 025 = 0 025 X 0 00015 = 0 00075 X 0 00084 = 0 01176 X 004 = 012 0.18951 = AMPS Current Total Current (Amnsl (Amnsl 1 X 0 032 = 0 032 1 X 0 025 = 0 025 5 X 0 00015 = 0 00075 14 X 0 0196 = 0 2744 3 X 01 = 03 9 X 0 066 = 0 594 1.22615 = AMPS Required Standby Time in Hours 0 189 1 X 24 = 4 55 Required Alarm Time in Hours (15 MI NUTES) 1 226 5 X 0 25 = 0 31 Batteries BEDROOM ( 9' 0 ) � o�sw 4 85 = 5 83 7AH Minimum �� �--� � �--, �, i �� i i�i i �� �� L__ � � L__ J �� - SWITCHING FOR LNING � I � � � ROOMLIGHTSLOCATED �� I �� i� E ECTRICALpLAN WER& , , , o, � \\ � // \ � / � i � ` i � � � .�, � OPEN TO �---�ELOW---� � � � � BATH i i i i ii L____� L____J II I I c 9 0 � CORRIDOR O i H �� 018 � _ � i CORRIDO i H __ _-I_ -- � � �� i � �i ��� 016 ? CLOSET 1 i i caa i BATH ��� ` � � � j�� // �� � �\ �� i i � i i i i �� / i �- � -� \�� � _� � LAUND �5�`aG� 1 �'� � � i ce > L �__ � r�--� �l iii iii LI__J II LINE �BATH ( 9 0 ) BEDROOM � H I i � FRQM BELI � � ii � �� ? 014 i � E-----�---� BEDROOIVr � � � i UPPER LEVEL FLOOR PLAN � SCALE I/8" = I'-O" NORTi1 GENERAL NOTES: 1. ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALl�4TI0N INSTRUCTIONS FOR FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, PROGRAMMING AND DEVICE OPERATION. 0 �. �� � ri .1,;,� �� � �a�� � ` �I�,�i��'." � �� k = 4 'm� • ,�'��:a� _ r�'e�� � �,,.�. ... , j,�:• � � - ��� L .,;i.r. ���� . - ! �-,� - � .�---�., LEGEND: SYMBOL DEVICE MANUFACTURER PART MOUNTING FACP Ademco Vista-50P Fire Alarm Control Parel w/ 7AH Batteries Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Ademco 6139 Mount on wall in manufacturer backbox OPhotoelectric Smoke D:tector Ademco 5192SD 4" square box � Heat Detector Chemetronics 601 w/4193SN Addressable module 4" square box H❑ Sounder System Sensor MHW Single gang box OW Wireless Smoke Detector Ademco 5808 4" squQre box �yy Wireless Heat Detector Ademco 5809 4" square box � Knox Box 1 PAIR DATA 1 PAIR SOUNDER EOLR �9 �YP) �5 �YP) �� ? �YP) KP ADEMCO VISTA 50P DIALER DEDICAT�D 120V J I I TELE LINES� SYSTEM ONE—LINE DIAGRAM NOTE 1. NO T—TAPPING PERMITTED ON ANY CIRCUIT NOTE 2. ALL WIRING TO BE 18AWG FPL. SEQUENCE OF J J Q OPERATIONS: � � Z N N J � O (n O � O p tn N � Fa- J I-a- N H � W � g(n m tn � tn � a Z= gZ �°Z a Z � a � N � N p � � � � � � = Z Z Z DEVICE Q Q� � o N o � o DESCRIPTION � � � U U 2 � OO ��,O � O a a � SYSTEM SMOKE OR HEAT DEfECTORS X X X AC POWER LOSS ' X X GROUND FAULT X X OPEN CIRCUIT X X PROJEGT INFORMATION: ZUG RESIDENCE 1548 SPRING HILL LANE VAIL, COLORADO FIRE ALARM SYSTEM AHJ: VAIL FIRE DEPARTMENT APPLICABLE CODES: 2002 NFPA 72, 2003 IFC, 2003 IBC OCCUPANCY: GROUP R USE: SIPJGLE FAMILY HOME FIRE ALARM SYSTEM FOR REMODELED HOME. SYSTEM INCLUDES BOTH WIRED �ND WIRELESS SMOKE AND HEAT DETECTORS, WIRED SOUNDERS AND A CONTROL KEYPAD. THE PORTIONS OF THE HOME THAT ARE BEING REMODELED WILL HAVE WIRED DEVICES. A KNOX BOX WILL BE PROVID�. � L� C� C � � �� THE 120VAC FOR THE FACP IS FROM A DEDICATED BREAKER. APR 2 3 2009 CEILING� ARE SMOOTH, FLAT AND UNDER 10'. o�� �� �v��� SYSTEM WILL BE MONITORED BY CENTRAL SECURITY. � FIRE P�OTECTION ENGINEER: o�°� E� �• ��s�, DEBORAH SHANER, P.E., SHANER LIFE SAFETY �`';�� z:° PO BO�C 1073, FRISCO, CO 80443 �:0 3 2 3 �: PHONE 970-409-9082 " FAX: 970-797-1898 r -�'o '• , '� �` , • � ,. � -f �.�SSi�' G , `,• , ��„�,.,a. .a ��� H% y'�� /� � )[a. ������,.�,� ���%� ::F . ��, �` ; � �/�/i�,.�i���'%�; �i� �/ <; . �,���'' � �/i!�w`: '� .:... ��'' ��.,; �� �����,//���i�' %H. � U Q o 0 o ao f— J � O N N N J c� � � �n �n � O� � N N w UQO � o o rn � W � m Q • • c� a p � � o � O �� J o� rn ZJ � � W x QO a z o � W � o = � Z v Q °- �� z W W Z I— 0° a� ° 0 W — � �� �o W F- W � U } � w � � � �, a W J � Q �r W � � N IL Z O � �-- f- � U U — W W � � � U O O c� � � o � z 0 � > W � , l� � r` W �y_.� J ] T � � O ��o � U � � � �A �n � _ � � ✓ > , _ 1" � � \� U W u� O� �J � , � \ � � � w � ° z cn � cn ��� (� J � J N � 0 � � � w o 0 vi Z Q �� �- w �� O � �� � Z p O w o w~ (� � W � � � � � � � II � � Z � - W O � � � � Q C7 Q U � W Z J Z � � U � J � � Q �W U 0 U (n (n FIRE ALARM SYSTEM FA-00