HomeMy WebLinkAboutPEC130007 Variance Request Letter michael@sumanarchitects.com 141 East Meadow Drive, Suite 211 o 970.479.7502 Vail, CO 81657 m 970.471.6122 January 28, 2013 Riva Ridge Unit 640 Remodel Riva Ridge, Lot 6, Block 6 Vail Village 1st Filing Variance Application for Side Setback RE: Section 12-6H-6, Setbacks, Vail Town Code 1. Description of Variance Requested The Riva Ridge Unit 640 owners have a growing family needing more space and would like to enclose areas of their existing decks. They are entitled to an additional 250 sq. ft. per the 250 ordinance which is still available for each unit. The existing building was originally constructed with encroachments in all setbacks around the site. The variance being requested will allow approximately 122 sq. ft. of GRFA to be constructed within the West setback above existing encroachment areas on the garage level. Below is a detailed breakdown of the existing conditions: Zoning Statistics Lot size: 11,930 sq. ft. (0.274 acres) Zoning: High Density Multiple Family Development Standard Allowed/Required Existing Proposed Setbacks: West 20 ft. 4 ft. No Change South 20 ft. 6 ft. No Change East 20 ft. 0 ft. No Change North 20 ft. 9 ft. No Change Site Coverage: 6,566 sq. ft. 7,156 sq. ft. No Change GRFA: 7,158 sq. ft. 13,598 sq. ft. 13,720 sq. ft. (increase of 122 sq. ft.) Landscape Area: 4,374 sq. ft. 4,374 sq. ft. No Change Total Proposed Additional GRFA in Setbacks 122 sq. ft. The property was built in 1968 prior to the adoption of zoning regulations within the Town of Vail. It subsequently was zoned High Density Multiple Family and immediately rendered existing Non- Conforming because the building was originally constructed in all required setbacks. This pre-existing nonconforming condition through no fault of the applicant(s) is a hardship based on the strict and literal interpretation of the code as any perimeter expansion or deck enclosure will require approval of a variance from the required 20 foot setback. michael@sumanarchitects.com 141 East Meadow Drive, Suite 211 o 970.479.7502 Vail, CO 81657 m 970.471.6122 2. Analysis of Proposal Given the existing plan constraints, the decks are the only practical areas for addition that do not change the perceived bulk and mass of the building. In addition, the west facing deck proposed to be enclosed, stacks above an existing encroachment at the Garage Level below. Existing deep roof overhangs of the structure extending beyond the edge of decks define the perceived bulk and mass of the building. The proposed deck enclosure moves the existing exterior wall of the unit out approximately 5’-0” yet stays within the roofline. Because the new enclosed area will reside below the existing roof line without modifying it and above the lower level encroachment, it will blend in with the current architecture. The adjacent property to the West is Willow Park open space. Also, existing large mature evergreen trees screen the entire west façade of the building including the proposed area of expansion. Based on location and the existing tree stand to remain, the proposed expansion has no impact on development standards and neighboring properties. Photo 1 – Shows the existing trees that will screen the new enclosure and the existing West setback encroachment on the Garage Level below it. Photo 2 – Shows the existing trees on the Southwest corner of the building Photo 3 – Shows how the center portion of the Riva Ridge south building has solid mass in the center of the façade similar to what is being proposed in this application. 3. Approval Criteria Based on practical difficulties, the requested variance will allow Units 640 to take advantage of the 250 ordinance which they are entitled to. Many precedents for this type of variance being granted exist: for example at the Tyrolean Condominium Building. Therefore, the proposed variance is not a grant of special privilege given the non-conforming condition of the existing building; precedence; small size of the addition; and it’s negligible impacts to anything. 4. Effect on light and air, distribution of population, transportation and traffic facilities, etc. The proposed variance will have no affect on these items. michael@sumanarchitects.com 141 East Meadow Drive, Suite 211 o 970.479.7502 Vail, CO 81657 m 970.471.6122 PHOTO 1 – West Façade where deck enclosure is proposed michael@sumanarchitects.com 141 East Meadow Drive, Suite 211 o 970.479.7502 Vail, CO 81657 m 970.471.6122 PHOTO 2 – South Façade of existing building and applicants SW corner unit michael@sumanarchitects.com 141 East Meadow Drive, Suite 211 o 970.479.7502 Vail, CO 81657 m 970.471.6122 PHOTO 3 – Riva Ridge South showing similar massing to what is being proposed