Loading...
HomeMy WebLinkAboutB12-0637 permitNOTE: THIS PERM/T MUST BE POSTED ON JOBS/TE AT ALL T/MES .� TO�t OF VAtL' . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B12-0637 Job Address: 770 POTATO PATCH DR VAIL Location......: Potato Patch Club Unit 3 Parcel No....: 210106319003 CONTRACTOR WARING CONSTRUCTION INC. 01/29/2013 ROB WARING 419 CHAROLAIS CIRCLE EDWARDS CO 81632 License: C000003746 OWNER DENNIS S. PARSONS & KATHRIN 12/26/2012 DENNIS S. & KATHRIN R. PARSONS TRUSTEES PO BOX 1070 KENWOOD CA 95452-1070 APPLICANT SNOWDON AND HOPKINS, ARCHITE 12/26/2012 PO BOX 3340 VAI L CO 81658 License: C000001763 ARCHITECT SNOWDON AND HOPKINS, ARCHITE 12/26/2012 PO BOX 3340 VAIL CO 81658 License: C000001763 Project #: PRJ12-0544 Applied.....: Issued. . . . Phone: 970-471-9276 Phone: 970-476-2201 Phone: 970-476-2201 Description: INTERIOR REMODEL OF EXISTING UNIT AND ADDITION OF NEW SQUARE FOOTAGE AT MAIN LEVEL KITCHEN/DINING ROOM AND UPPER LEVEL STUDIO. Occupancy: R-2 Type Construction: VB 12/26/2012 01 /29/2013 Valuation: $223,000.00 ..,, .............................,,.....,..................,.,,,......,,........_... FEE SUMMARY « ................>.,.........,...........,.......,....,...,,...,...,..,,,....,.. Building Permit -----------> $1,682.55 Bldg Plan Check ----------> $1,093.66 Use Tax Fee-----------------------> Electrical Permit ---------> $0.00 Elec Plan Check -----------> $4,260.00 Mechanical Permit ------> $0.00 Restuarant Plan Review--------> $0.00 $400.00 Mech Plan Check ---------> $100.00 Additional Fees-------------------> Plumbing Permit --------> $270.00 Plmb Plan Check ---------> $67.50 Recreation Fee--------------------> $Z00.00 $36.30 Investigation-----------------------> $0.00 Will Call------------------------------> $20 00 TOTAL PERMIT FEES--------------> a8,130.01 Payments-------------------------------> $8,130.01 .«,.,, ...................................,......,....,........._.>..,...,..,..».......,.......,........,........�,,..BALANCE DUE.=..._............,,�,...,..,,.....$0*00..,. DECLARATIONS i agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 ��� � " � , � .,.�........x«.� .................................>......+_..:................�...»......:.........,....................,............»...._...................._...........,,........_... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B12-0637 Address: 770 POTATO PATCH DR VAIL Owner: DENNIS S. PARSONS & KATHRIN R. PARSONS REVOCABLE TRUST Location: Potato Patch Club Unit 3 ... � ..............................................................,.............,,,...,..,.,....,,..,......,,........,.,..............,...............,,......,...,......,...,......,.. Cond: CON0013018 The applicant shall screen the new AC unit with landscaping. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 combination permit_012811 3 � T'��?NQF YAI� ' *,***********************w***********,************,.********************.**,***********************************,**********�******.*..**.************.** REQUIRED INSPECTIONS AND STATUSES Permit #: 612-0637 Address: 770 POTATO PATCH DR VAIL Owner: DENNIS S. PARSONS & KATHRIN R. PARSONS REVOCABLE TRUST Location: Potato Patch Club Unit 3 ,.*„****.,***«*«**«**«*«„************,.********,.*****«**«********,�**********�*«**««*.,«****.,**,.«,.«***************«**«****.«**«**w«**„*****************.,.* Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00230 PLMB-Rough/Water Item: 00240 PLMB-Gas Piping Item: 00310 MECH-Heating Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00542 PLAN-FINAL Item: 00090 BLDG-Final combination permit_012811 *****+**************+*********************************+************************************* TOWN OF VAIL, COLORADO Statement *****************************+******************************+******************************* Statement Number: R130000058 Amount: $6,868.85 O1/29/201311:22 AM Payment Method: Check Init: CG Notation: ck 1043 waring construction --------------------------------------------------------- Permit No: B12-0637 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-1900-3 Site Address: 770 POTATO PATCH DR VAIL Location: Potato Patch Club Unit 3 Total Fees: $8,130.01 This Payment: $6,868.85 Total ALL Pmts: $8,130.01 Balance: $0.00 *****************************************************+************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 CL 00100003123000 MP 00100003111100 PP 00100003111100 RF 11100003112700 UT 11000003106000 WC 00100003112800 Description ------------------------------ BUILDING PERMIT FEES CONTRACTOR LICENSES MECHANICAL PERMIT FEES PLUMBING PERMIT FEES RECREATION FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 1, 682.55 200.00 400.00 270.00 36.30 4,260.00 20.00 ----------------------------------------------------- r ************************************************«******************************************* TOWN OF VAIL, COLORADO Statement *******************+***********************+****r***+*+******************************s****** Statement Number: R120002023 Amount: $1,261.16 12/27/201210:22 AM Payment Method:Credit Crd Init: CG Notation: visa dennis parsons ----------------------------------------------------------------------------- Permit No: B12-0637 Type: COMBINATION BLDG PERMIT Parcel No: 2101-063-1900-3 Site Address: 770 POTATO PATCH DR VAIL Location: Potato Patch Club Unit 3 Total Fees: $7,893.71 This Payment: $1,261.16 Total ALL Pmts: $1,261.16 Balance: $6,632.55 ***************************************************************a**************************** ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 Description Current Pmts ------------------------------ ------------ PLAN CHECK FEES 1,261.16 ----------------------------------------------------------------------------- TOWN �75 S� ONTAGE RDOM DEU UAIL� CO 81651 918-479-2324 1ERMINAL I.D.� 2082 PERCHAHT N; UISA i�t���t�k�k#6482� MAIL ORDER BRTCH; BBA631 �UT H : 0380�D DEC 27� 12 10:14 TOTAL $1261.16 CUS101�R COP4 06 -10 -2014 Inspection Request Reporting Page 1 4:20 pm _ Vail, CO - City-Of_ Requested Inspect Date: Wednesdayy June 11, 2014 Site Address: 770 POTATb PATCH DR VAIL Potato Patch Club Unit 3 A /P /D Information Activity: B12 -0637 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: R -2 Insp Area: Contractor: WARING CONSTRUCTION INC. Phone: 970 - 471 -9276 Owner: DENNIS S. PARSONS & KATHRIN R. PARSONS REVOCABLE TRUST Applicant: SNOWDON AND HOPKINS, ARCHITECTS, P.C. Phone: 970 - 476 -2201 Architect: SNOWDON AND HOPKINS, ARCHITECTS, P.C. Phone: 970 - 476 -2201 Description: INTERIOR REMODEL OF EXISTING UNIT AND ADDITION OF NEW SQUARE FOOTAGE AT MAIN LEVEL KITCHEN /DINING ROOM AND UPPER LEVEL STUDIO. Comment: E- SUBMITTAL IN LASERFICHE. - DRHOADES Comment: called architect to pick up no listed contractor - MHAEBERLE Comment: pirmit extension to 6/08/2014 SHANE Comment: NO INSPECTIONS UNTIL PAYMENT RECEIVED..... bounced check Rob Warinq was informed he can not use a credit card to pay the NSF check. Jacque is going to contact Rob letting him know he must pay by Monday February 11 th. Informed Jacque the permit has ock on it so no inspections can be entered. The lock wild be removed u on receipt of payment. - LCAMPBELL Comment: Mr. Waring brought in cashiers check to cover bouncXlcheck. Permit is in good standing. - LCAMPBELL Comment: Left message on contractor cell number check is a NSF and needs to be replaced with cash or cashiers check only. The payment will be paid in finance to the attention of Jacque Lovato. Also informed on the message his permit is LOCKED. - LCAMPBELL Requested Inspection(s) Item: 542 PLAN -FINAL Requested Time: 08:00 AM Requestor: WARING CONSTRUCTION INC. Phone: 970 - 471 -9276 Assigned To: GF4TH Entered By: JMONDRAGON K Action: Time ELx�p: Inspection History Item: 120 ELEC Rou h ** Approved ** 05/23/13 Inspector: mdenney Action: AP APPROVED Comment: Item: 200 MECH -Rough *` Approved ** 06/05/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB - Rough /D.W.V. ** Approved ** 05/23/13 Inspector: mdenney Action: PI PARTIAL INSPECTION Comment: kitchen only. island sink must have an air admittance valve. 06/05/13 Inspector: sgremmer Action: DN DENIED Comment: Flow test and notch plates required support pipe under floor at Mstr bath 06/06/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB- Rough/Water ** Approved ** 05/23/13 Inspector: mdenney Action: PI PARTIAL INSPECTION Comment: kitchen only 06/05/13 Inspector: sgremmer Action: DN DENIED Comment: Notch plates required 06/06/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB -Gas Piping ** Approved ** 06/05/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 06/05/13 Inspector: sgremmer Action: DN DENIED Comment: Need MEP's to pass 06/06/13 Inspector: sgremmer Action: AP APPROVED Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 06/13/13 Inspector: JRM Action: AP APPROVED Comment: Item: 190 ELEC -Final " Approved ** 01/08/14 Inspector: sgremmer Action: DN DENIED Comment: Romex exposed in cabinet at mstr bath to be protected 06/04/14 Inspector: sgremmer Action: AP APPROVED Comment: Item: 290 PLMB -Final ** Approved ** 01/08/14 Inspector: sgremmer Action: DN DENIED Comment: caulk water closet at mstr bath REPT131 Run Id: 14834 06 -10 -2014 Inspection Request Reporting 4:20 pm Vail, CO, ity Of 06/04/14 Inspector: sgremmer Action: AP APPROVED Comment: Item: 390 MECH -Final " Approved " 01/08/14 Inspector: sgremmer Action: AP APPROVED Comment: Item: 542 PLAN -FINAL Item: 90 BLDG -Final 01/08/14 Inspector: sgremmer Action: DN DENIED Comment: lanning to sign off Provide CO2 detectors w/ in 15' of bedrooms windows at mstr shower to be safety glazed 06/04/14 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: need planning to sign off REPT131 Page 2 Run Id: 14834 Inspection Items for B12-0637 10:36 12/15/2014 Sec Item Id Description A r Re Items Action Inheritable * 120 ELEC-Rou h Yes R 1 AP No _ 200 MECH-Rou h Yes R 1 AP No " 220 PLMB-Rough/D.W.V. Yes R 3 AP No * 230 PLMB-Rou h/Water Yes R 3 AP No ' 240 PLMB-Gas Pi in Yes R 1 AP No ' 30 BLDG-Framin Yes R 2 AP No ' __ 60 BLDG-Sheetrock Nail Yes R 1 AP No ' _ 190 ELEGFinal Yes R 2 AP No * 290 PLMB-Final Yes R 2 AP No " _ 390 MECH-Final Yes R 1 AP No " 542 PLAN-FINAL Yes R 2 AP No " 90 BLDGFinal Yes R 3 AP No Total Rows: 12 Page 1