HomeMy WebLinkAboutB07-0108 **�**��**********�*��**��****************r*****�****r****s**s*********�****************�****
TOWN OF VAIL, COLORADOCopy Reprinted on 01-31-2013 at 11:14:25 O1/31/2013
Statement
**.*****�*****�*�*.*��***r*r**.*****r�*****����*�*************r********�**��*****r**r*�*����
Statement Number: R070000781 Amount: $1, 873. 69 05/24/200709: 15 AM
Payment Method: Check Init: LC
Notation: #5553/KITCHELL
DEVELOPMENT
-----------------------------------------------------------------------------
Permit No: B07-0108 Type: ADD/ALT COMM BUILD PERMT
Parcel No: 2101-071-0300-1
Site Address: 520 LIONSHEAD CR VAIL
Location: LIONSHEAD CENTER
Total Fees: $1, 873. 69
This Payment: $1, 873. 69 Total ALL Pmts: $1, 873. 69
Balance: 50.00
*rs*r*r�***��***�***���******��***s**************�******r*******�*******�**�*�******«*****ss
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 1, 133.75
PF 00100003112300 PLAN CHECK FEES 736. 94
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL,CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ADD/ALT COMM BUILD PERMT Permit # B07-0108
Project# PRJ07-0148
Job Address: 520 LIONSHEAD CR VAIL Status . . . : FINAL
Location.......: LIONSHEAD CENTER Applied .. . : 04/20/2007
Parcel No....: 210107103001 Issued . . . : OS/24/2007
Expires.....: 11/12/2007
OWNER T J T CO INC 04/20/2007
$ VAIL HOME RENTALS
143 E MEADOW DR STE N-90
VAIL
CO 81657
APPLICANT KITCHELL DEVELOPMENT 04/20/2007 Phone: 970-390-1381
P. 0. BOX 2558
VAIL
CO 81658
License: 101-B
CONTRACTOR KITCHELL DEVELOPMENT 04/20/2007 Phone: 970-390-1381
P. 0. BOX 2558
VAIL
CO 81658
License: 101-B
Desciption:
INSTALL A SPRINKLER SYSTEM CHASE
Occupancy: R2,S2,A2
Type Construction: II B
Valuation: $124,950.00 Revision Valuation: $0.00 Total Sq Ft Added: 0
•�s*+*rtwsss*�+s�+ass►s�4*�*s�sstas*s*s�s*K*ss���**�*�+s*�*��s*s*s*s* FEE S UMMARY #i4#�F#t#t##it#�Ii**#4Rtti4#**�F4f*it#t#t#ti+1�F##f#i#�F#ti��Yit#i4►
Building-----> S1,133.75 Restuarant Plan Review--> S0.00 Total Calculated Fees--> $1,873.69
Plan Check—> $736.94 Recreation Fee ---> $0.00 Additional Fees----------> $0.00
Investigation-> S0.00 TOTAL FEES --> S1,873.69 Total Permit Fee------> S1,873.69
WillCall—> $3.00 Payments-----------> $1,673.69
BALANCE DUE-------> S0.00
kitttt#iif►tiilt�If4tf#4i*4�F##tRf#t#it##t#trti##ti4i#f44ti4�R4t*�t1�+R####t###t#t#**4i#iff#�4t#tft##�1#R##k#*t#fit�i*ft#t###f4t#ftt#t##�FRiirtitti*4►ft#i
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/07/2007 cdavis Action: DN More information
required.
Permit application was submitted with
sprinkler isometrics only. Does not contain any
information of Type of Construction, penetration
patching, where sprinklers are being run, soffit
construcytion, location of soffit construction.
Held meeting with "new Architect of Record" on 5/7/07 and
communicated all items needed for building permit
submital. Meeting notes forthcoming
05/2�3/2007 cdavis Action: AP Make note of
corrections listed under this permit and subject to field
inspection
06/25/2007 cdavis Action: PA Fire-stopping
methods for through-penetrations approved for use with
non-combustible piping through walls only
07/05/2007 cdavis Action: PA Additional details
for soffit/Steel Beam Fire Protection approved
09/05/2007 cdavis Action: AP Fire Retardant
Paint Product "Flame-Stop II approved
Installation of product must occur on or about September
17, 2007 and be complete within Ten working days
Approval of engineered inspection of insulation materials
in question above the Garfinkles Space. All remiedail
work concerning the insulation as detailed in report from
Schirmer Engineering dated 8/31/07 must be complete prior
to the Thankgiving weekend 2007
Item: 05400 PLANNING DEPARTMENT
04/20/2007 JS Action: AP
Item: 05600 FIRE DEPARTMENT
05/07/2007 mvaughan Action: DN permit submitted
on sprinkler plans belonging to All State Sprinkler. No
construction detail supplied. resubmit.
09/04/2007 mcgee Action: AP Fire retardant for
exterior siding is approved with use of Flame Stop II .
Fire-Shield product is not approved for use on exterior
siding.
i�#tttRfil4it#4ii�Rt#t##tt#titt#*t#t#ft#t#R#R#i#R#4f�i4#t##i###t�*####ktitit*4#ttt#4T41t#f4i4###t�#►i*4#�#i*t##*t#tft#t#4ft#tt#4#ts4R#ft�4��t►f�t
See the Conditions section of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM•
4 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
********************************************************************************************************
' CONDITIONS OF APPROVAL
Permit#: B07-0108 as of 01-31-2013 Status: FINAL
*********************#**********************************************************************************
Permit Type: ADD/ALT COMM BUILD PERMT Applied: 04/20/2007
Applicant: KITCHELL DEVELOPMENT Issued:
OS/24/2007
970-390-1381 To Expire: 11/12/2007
Job Address: 520 LIONSHEAD CR VAIL
Location: LIONSHEAD CENTER
Parcel No: 210107103001
Description:
INSTALL A SPRINKLER SYSTEM CHASE
***********************************************Conditions:************************************************
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
1
B07-0108 : Entries for Item:90 - BLDG-Final 11:14 01/31/2013
Action Comments By Date Unique_
Ke
NO Perfonned inspection of the above-ceiling cdavis 10/15/2007 A000106
elements of the Garfinkle's space.This area 303
was identified by VFES of having potiential
issues with the installation of combustible
insulation,wiring issues and potential for fire to
spread in a concealed area.
A special inspection report was generated by
Schirmer Engineering and submitted to this
office on August 31,2007.This report outlined
the condtions of the abnove-ceiling element.
On Page four of this document were 2
recommendations to remediate concers of the
insulation installation.
Both reccomendations have been completed
and confirmed by inspection that occurred by
me on 10/8/07
-Insulation has been removed from all non-IC
rated fixtues a minimum of 6"
-All paper back insulation has been removed
from the Above Ceiling Area.
AP All work complete for this building permit cdavis 11/12/2007 A000107
Recieved final report stating that Fire 581
Retardant Paint has been applied to the
building exterior.
A new C of O will not be issued.
Total Rows:2