MECHANICAL PERMIT
ASFR
Job Address: 996 PTARMIGAN RD VAIL
Location.....: 996 PTARMINGAN
Parcel No...: 210108115003
OWNER OML INVESTMENTS INC 09/05/2007
975 AMERICAN PACIFIC DR STE 104
HENDERSON
NV 89014
APPLICANT STORM KING MECHANICAL 09/05/2007 Phone: (970)625-8551
2335 AIRPORT ROAD, BLD 1, ST A
RIFLE
CO 81650
License: 276-M
CONTRACTOR STORM KING MECHANICAL 09/05/2007 Phone: (970)625-8551
2335 AIRPORT ROAD, BLD 1, ST A
RIFLE
CO 81650
License: 276-M
Desciption: INSTALL A 2 BOILER SYSTEM, SIDE ARM WATER HEATER; INFLOOR
HEAT, SNOWMELT, EXHAUST FANS, DRYER, GAS PIPING, NOT
INSTALLING FIREPLACE OR FLUES.
Valuation: $75,000.00
ALL T/MES
Permit #: M07-0191
Project #:
Status . .
Applied .
Issued .
Expires .
FINAL
09/05/2007
09/O6/2007
08/29/2008
..., ..................,�.............�.........*.........�...,t....,.....,...�.......FEE SUMMARY.......>...,...........�.�<......«.......,.....�...,,............«.....................
Mechanical Permit Fee---> $1,500.00 Will Call------------> $4.00 Total Calculated Fees---> $1,879.00
Plan Check-------------------> $375.00 Use Tax Fee------> $0.00 Additional Fees-----------> $0.00
Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $1,879.00
Total Calculated Fees--> $1,879.00 Payments-----------------> $1,879.00
BALANCE DUE---------> $0.00
.«.�....«.,,........�:..,�..�.*:,�..........,.�.,�...«..,.,......,..,t.,...«., ..................:....,t.*«........,'.«........�..,..*.......,.,....,.�x,.,.......,...««...�....,.......».............«.....
APPROVALS
Item: 05100 BUILDING DEPARTMENT
09/05/2007 cgunion Action: AP
Item: 05600 FIRE DEPARTMENT
..,.....* ..............<.,�..................*.....,...:....,....+<�.*..«,....,......,.............+....................................�...........................................,.........,
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG 2003): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND
SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG 2003): BOILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS
AND CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG 2003): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003
IFGC.
Cond: 29
(BLDG 2003): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE
2003 IMC AND CHAPTER 3 OF THE 2003 IFGC..
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
mech ca n i ca I_pe rm it_041908
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
.....,...,.........,.,t«..........,..«....�..,,..::...«.......�....,....,.,t...........,�........*..,t�.......:�.....:�,+....�,..««.........» ...............,t..,�.......««...........................
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(
AM - 4 PM.
Signature of Owner or Contractor
Print Name
m e ch ca n i ca I_pe rm it_041908
Date
****+******+*****+***�**+****+*****************************************+**************++****
TOWN OF VAIL, COLORADOCopy Reprinted on 02-06-2013 at 15:32:29 02/06/2013
Statement
****************************************+******************+*+**************************+***
Statement Number: R070001779 Amount: $1,879.00 09/06/200702:38 PM
Payment Method: Check Init: DDG
Notation: Storm King
Mechanical 8152
-----------------------------------------------------------------------------
Permit No: M07-0191 Type: MECHANICAL PERMIT
Parcel No: 2101-081-1500-3
Site Address: 996 PTARMIGAN RD VAIL
Location: 996 PTARMINGAN
Total Fees: $1,879.00
This Payment: $1,879.00 Total ALL Pmts: $1,879.00
Balance: $0.00
************************************+******************************************+************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
MP 00100003111100 MECHANICAL PERMIT FEES 1,500.00
PF 00100003112300 PLAN CHECK FEES 375.00
WC 00100003112800 WILL CALL INSPECTION FEE 9.00
-----------------------------------------------------------------------------
08-28-2008 Inspection Request Re orting Page 38
4 33 pm Vail, C� Citv
Requested Inspect Date: Friday, August 29, 2008
Inspection Area: CG
Site Address: 996 PTARMINGAN D VAIL
A/P/D Information
Activity: M07-0191 Type: B-MECH Sub TUse; ASFR Insp Area: CGUED
Const Type: Occupancy:
Owner: OML INVESTMENTS INC
Contractor: STORM KING MECHANICAL Phone: (970)625-8551
Description: FANS DRx� ,F� GA��PIPING MNOT INSTALLINGTF REPLAATCE�OR FL�U� SHEAT, SNOWMELT, EXHAUST
�i
�
�
Iter� 39.b MECH-Final Requested Time: 04:00 P
�equestot� Greg Bartock Phone: 376-0132
:omment : will call Greg 376-013 , Mech., plumbing, PW and Bldg. finals ar Entered By 1e DGOLDEN K
signed T�: JMONDRAGON Time Exp
Action,; b gE ON SITE DU C''I`i.ON.
Comment:`�•
`�IPE TH SSURE RELIEF WITHIN 6 I HES C)F FLOOR.
SIDE � COUPLING IS LEAKING. `
CHECK FOR BACKFLOW PREVENTION F R BOILE�Z AND NEUTRALIZER.
CHECK BOILER TERMINATION HEIGHT O�1 EXTERIOR, AS IT IS ONLY 18 INCH ABOVE GRADE.
� �, }---��
_ �, j ,;
P t,'v
i'�• �`� `-'�
; � ,�'
;�' 1. /`�"� l
, ��, / , ,
f ,,
i 4 f �, 1'
� ��� r
l � i
� I
.� �
1
I;
';i
Inspection Historv �
Item: 200 MECH-Rough " Approved "' Action: PA PARTIAL APPROVAL
09/07/OT Inspector: mgsafe
Comment: bath and dryer exhaust Action: AP APPROVED
06/25/08 Inspector: JRM
Comment: bath fan approved
Item: 310 ME1 24%07�nfnspector: JRMApproved `" Action: PA PARTIAL APPROVAL
Comment: TESROVED LIVING ROOM, KITCHEN, MASTER BATH AND BATH2 INFLOOR HEAT 100 # AIR
10/29/07 Inspector: shahn Action: PA PARTIAL APPROVAL
Comment: MASTER AND BEDROOM AND ENTRY WISBRO 100# AIR
11/12/07 Inspector: dplace Action: NR NOT READY FOR INSPECTION
Comment: not ready for pressure test.
11/14/07 Inspector: dplace Action: AP APPROVEQ
Comment: 100 psi pressure test approved.
Item: 315 PLMB-Gas Pipin�g
Item: 320 MECH-Exhaust Hoods
Item: 330 MECH-Supply Air
ttem: 340 MECH-Misc.
Item: 390 MECH-Final Action: CR CORRECTION REQUIRED
08/27/08 Inspector: shahn
Comment: CONTRACTOR TO BE ON SITE DURING INSPECTION.
PIPE THE PRESSURE RELIEF WITHIN 6 INCHES OF FLOOR.
SIDE ARM COUPLING IS LEAKING.
CHECK FOR BACKFLOW PREVENTION FOR BOILER AND NEUTRALIZER.
CHECK BOILER TERMINATION HEIGHT ON EXTERIOR, AS IT IS ONLY 18 INCH ABOVE
GRADE.
REPT131 Run Id: 8403