HomeMy WebLinkAboutM07-0191NOTE: THIS PERM/T MUST BE POSTED ON JOBSITE AT : TOWNOF VAII. ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 996 PTARMIGAN RD VAIL Location.....: 996 PTARMINGAN Parcel No...: 210108115003 OWNER OML INVESTMENTS INC 09/05/2007 975 AMERICAN PACIFIC DR STE 104 HENDERSON NV 89014 APPLICANT STORM KING MECHANICAL 09/05/2007 Phone: (970)625-8551 2335 AIRPORT ROAD, BLD 1, ST A RIFLE CO 81650 License: 276-M CONTRACTOR STORM KING MECHANICAL 09/05/2007 Phone: (970)625-8551 2335 AIRPORT ROAD, BLD 1, ST A RIFLE CO 81650 License: 276-M Desciption: INSTALL A 2 BOILER SYSTEM, SIDE ARM WATER HEATER; INFLOOR HEAT, SNOWMELT, EXHAUST FANS, DRYER, GAS PIPING, NOT INSTALLING FIREPLACE OR FLUES. Valuation: $75,000.00 ALL T/MES Permit #: M07-0191 Project #: Status . . Applied . Issued . Expires . FINAL 09/05/2007 09/O6/2007 08/29/2008 ..., ..................,�.............�.........*.........�...,t....,.....,...�.......FEE SUMMARY.......>...,...........�.�<......«.......,.....�...,,............«..................... Mechanical Permit Fee---> $1,500.00 Will Call------------> $4.00 Total Calculated Fees---> $1,879.00 Plan Check-------------------> $375.00 Use Tax Fee------> $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $1,879.00 Total Calculated Fees--> $1,879.00 Payments-----------------> $1,879.00 BALANCE DUE---------> $0.00 .«.�....«.,,........�:..,�..�.*:,�..........,.�.,�...«..,.,......,..,t.,...«., ..................:....,t.*«........,'.«........�..,..*.......,.,....,.�x,.,.......,...««...�....,.......».............«..... APPROVALS Item: 05100 BUILDING DEPARTMENT 09/05/2007 cgunion Action: AP Item: 05600 FIRE DEPARTMENT ..,.....* ..............<.,�..................*.....,...:....,....+<�.*..«,....,......,.............+....................................�...........................................,........., CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG 2003): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG 2003): BOILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG 2003): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG 2003): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. mech ca n i ca I_pe rm it_041908 Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. .....,...,.........,.,t«..........,..«....�..,,..::...«.......�....,....,.,t...........,�........*..,t�.......:�.....:�,+....�,..««.........» ...............,t..,�.......««........................... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. Signature of Owner or Contractor Print Name m e ch ca n i ca I_pe rm it_041908 Date ****+******+*****+***�**+****+*****************************************+**************++**** TOWN OF VAIL, COLORADOCopy Reprinted on 02-06-2013 at 15:32:29 02/06/2013 Statement ****************************************+******************+*+**************************+*** Statement Number: R070001779 Amount: $1,879.00 09/06/200702:38 PM Payment Method: Check Init: DDG Notation: Storm King Mechanical 8152 ----------------------------------------------------------------------------- Permit No: M07-0191 Type: MECHANICAL PERMIT Parcel No: 2101-081-1500-3 Site Address: 996 PTARMIGAN RD VAIL Location: 996 PTARMINGAN Total Fees: $1,879.00 This Payment: $1,879.00 Total ALL Pmts: $1,879.00 Balance: $0.00 ************************************+******************************************+************ ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 1,500.00 PF 00100003112300 PLAN CHECK FEES 375.00 WC 00100003112800 WILL CALL INSPECTION FEE 9.00 ----------------------------------------------------------------------------- 08-28-2008 Inspection Request Re orting Page 38 4 33 pm Vail, C� Citv Requested Inspect Date: Friday, August 29, 2008 Inspection Area: CG Site Address: 996 PTARMINGAN D VAIL A/P/D Information Activity: M07-0191 Type: B-MECH Sub TUse; ASFR Insp Area: CGUED Const Type: Occupancy: Owner: OML INVESTMENTS INC Contractor: STORM KING MECHANICAL Phone: (970)625-8551 Description: FANS DRx� ,F� GA��PIPING MNOT INSTALLINGTF REPLAATCE�OR FL�U� SHEAT, SNOWMELT, EXHAUST �i � � Iter� 39.b MECH-Final Requested Time: 04:00 P �equestot� Greg Bartock Phone: 376-0132 :omment : will call Greg 376-013 , Mech., plumbing, PW and Bldg. finals ar Entered By 1e DGOLDEN K signed T�: JMONDRAGON Time Exp Action,; b gE ON SITE DU C''I`i.ON. Comment:`�• `�IPE TH SSURE RELIEF WITHIN 6 I HES C)F FLOOR. SIDE � COUPLING IS LEAKING. ` CHECK FOR BACKFLOW PREVENTION F R BOILE�Z AND NEUTRALIZER. CHECK BOILER TERMINATION HEIGHT O�1 EXTERIOR, AS IT IS ONLY 18 INCH ABOVE GRADE. � �, }---�� _ �, j ,; P t,'v i'�• �`� `-'� ; � ,�' ;�' 1. /`�"� l , ��, / , , f ,, i 4 f �, 1' � ��� r l � i � I .� � 1 I; ';i Inspection Historv � Item: 200 MECH-Rough " Approved "' Action: PA PARTIAL APPROVAL 09/07/OT Inspector: mgsafe Comment: bath and dryer exhaust Action: AP APPROVED 06/25/08 Inspector: JRM Comment: bath fan approved Item: 310 ME1 24%07�nfnspector: JRMApproved `" Action: PA PARTIAL APPROVAL Comment: TESROVED LIVING ROOM, KITCHEN, MASTER BATH AND BATH2 INFLOOR HEAT 100 # AIR 10/29/07 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: MASTER AND BEDROOM AND ENTRY WISBRO 100# AIR 11/12/07 Inspector: dplace Action: NR NOT READY FOR INSPECTION Comment: not ready for pressure test. 11/14/07 Inspector: dplace Action: AP APPROVEQ Comment: 100 psi pressure test approved. Item: 315 PLMB-Gas Pipin�g Item: 320 MECH-Exhaust Hoods Item: 330 MECH-Supply Air ttem: 340 MECH-Misc. Item: 390 MECH-Final Action: CR CORRECTION REQUIRED 08/27/08 Inspector: shahn Comment: CONTRACTOR TO BE ON SITE DURING INSPECTION. PIPE THE PRESSURE RELIEF WITHIN 6 INCHES OF FLOOR. SIDE ARM COUPLING IS LEAKING. CHECK FOR BACKFLOW PREVENTION FOR BOILER AND NEUTRALIZER. CHECK BOILER TERMINATION HEIGHT ON EXTERIOR, AS IT IS ONLY 18 INCH ABOVE GRADE. REPT131 Run Id: 8403