HomeMy WebLinkAboutA12-0058 EHU stamped approved fire alarm LEGEND� SYMBOL DEVICE MANUFACTURER PART MOUNTING 4" 36" FACP Fire Alarm Control Panel AsBuilt 702 panel with 7AH Batteries Mount on wall MIN MINIMUM FINISHED CEILING � 2 P DIFFUSER � ❑F Manual Pull Station AsBuilt AB-42SK1 Single gang, 2-1/2" deep o 4" MIN TO TOP CEILING MOUNTED MIN 6" � 12" MAX TO BOTTOM SMOKE DETECTOR i MEASURE FROM TOP OF DEVICE a ❑Q WALL MOUNTED AUDIBLE DEVICE OO � O P Photoelectric Smoke Detector AsBuilt DISC-P w/DXP-4 Base Single gang or 4" square, 1-1/2" deep ��i, P w ❑ 96" MAX (TOP OF LENS) Photoelectric Smoke Detector � z WALL MOUNTED Osg w Sounder Base AsBuilt DISC-P w DXP-SND Base Sin le an or 4" s uare, 1-1 2" dee o 0 SMOKE DETECTOR � � WALL MOUNTED VISUAL OR AUDIBLE/VISUAL DEVICE � � �T 9 g 9 q � P o � > 80" MIN (BOTTOM OF LENS� O m � NOT LESS THAN Heat Detector AsBuilt DISC-T w/DXP-4 Base Single gang or 4" square, 1-1/2" deep = 90" ABOVE W MEASURE TO TOP OF CABINET � FACP FIRE ALARM CONTROL PANEL � Monitor Module AsBuilt DXP-PIM 4" square, 2-1/8" deep z 0 ENTIRE LENS v� SHALL BE sM > WITHIN 80"-96" MEASURE TO TOP OF UNIT Signal Module AsBuilt DXP-SDR 4" square, 2-1/8" deep � - LCD LCD ANNUNCIATOR 72„ TO CENTER OF DEVICE RT DUCT DETECTOR TEST STATION � ❑ Carbon Monoxide Detector System Sensor C01224T Mounting plate � w „ " ~ TO CENTER OF DEVICE �P MANUAL PULL STATION � Horn/Strobe, wall mount N o (candela specified) Cooper Wheelock HSW 4 Square or Single gang 64"-68" 0 60�� 42"-48" Strobe (candela specified) Cooper Wheelock STW 4" Square or Single gang � z � Horn/Strobe, wall mount � Weatherproof Cooper Wheelock ASWP-24MCHHFR Mount in weatherproof backbox � � ALL HEIGHTS MEASURED FROM FINISHED FLOOR o � STANDARD MOUNTING HEIGHT DETAIL --�-- � ' Sprinkler Waterflow Switch (By others) NOT TO SCALE � i � � • o 0 MOUNTING HEIGHT NOTES: '� ' Sprinkler Valve Tamper Switch (By others) � n � 1. MOUNTING HEIGHTS ARE PER NFPA 72 AND ADA ACCESSIBILITY GUIDELINES. ^` � 2. REMOTE LIGHTS AND REMOTE TEST STATIONS SHALL BE MOUNTED ON THE WALL BELOW ITS XXX = DEVICE ADDRESS ON LOOP ( 1 1 X ASSOCIATED DEVICE & SHALL BE CLEARLY VISIBLE. NX = NAC CIRCUIT NUMBER \�J 1 0 � 3. ADDRESSABLE MODULES SHALL BE MOUNTED AS TO BE ACCESSIBLE. �� � 4. WHERE LOW CEILING HEIGHTS DO NOT ALLOW FOR VISUAL OR AUDIBLE/VISUAL DEVICES TO � 1 � BE INSTALLED AS NOTED, APPLIANCES SHALL BE MOUNTED WITHIN 6" OF THE CEILING. GENERAL NOTES: 5. IN ADA UNITS, 110CD STROBES MUST BE MOUNTED 24" BELOW THE CEILING. 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6. MOUNT EXTERIOR HORN/STROBES 10' ABOVE FIRE DEPARTMENT CONNECTION. 2. WIRE AND CABLE SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70, NATIONAL ELECTRIC CODE AND PER � • MANUFACTURERS RECOMMENDATIONS. 3. FIRE ALARM VENDOR SHALL PROVIDE OPERATION AND MAINTENANCE MANUALS. THIS INFORMATION SHALL INCLUDE WIRING �` DETAILS, SYSTEM CIRCUITING, MOUNTING INFORMATION, DEVICE ZONE IABELING AND PROGRAMMING INFORMATION. ( 1 1 4. CONTRACTOR SHALL PERFORM ALL TESTS AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND NFPA 72. W 5. COORDINATE PLACEMENT OF FIRE ALARM DEVICES WITH OTHER TRADES. �� UDLTAGE DROP CALCULAT9�NS �� Project: Vail Fire 5tation EHU UNITS � � Panel: AsBuEUt 702 Wall Mount Valtage[3rop Su��n mary Sounder 15cd 15cd 75cd 110cc� � 2 Estimated Base 5trobe F�ornl5trobe HornlStr4be HornlStrobe Total Load Wire Voltage Drop L,P SB ��P SB �_ Circuit# Sourc� oescripti�n Type L�rogth �ft} 0.Q25 (].�57 0.082 C1.148 0.197 {Rmps} Gauge {4 VoVts Max} � L P SM P /�� ( N1 FACP �1ornlStrobes NAC 450 1 3 2 2 0.993 14 2.1 WP W N2 �ACP 5ounder8ases Power 250 fi 0.�50 �4 C1.2 � p Q P EOLR � � o Grand Total: 6 1 3 2 2 1.143 r i }- -� 0 p� Note 1: NACS are rated for 3 amps ea�h. � L Z LZ L L L L L ASBUILT � hlote 2:Assumed inputvoltage of 15V. Devices have an aperating range of 16-31 W�.{2Q,4 starting vvltages -�6�olts =4.4 Volts maxd�op in circuit) 1 2 SB � PL F 702 FACP ( Q (5) (3) (2) (>>) (6) (15) (5) � r� O N� EOLR o O ASBuilt 7�12 FACP DEDICATED 120V A� C1> C7> � X O �attery Calcula�ians TELEPHONE LINE 0° N o � Standfay Numb�c of Current 7�taf Current � � Qevice Type �,��„�S7 4,�mp�� SYSTE M 0 N E LI N E D IAG RAM Base Panel 1 X a.16 = Q.16 CCR Comman Card 1 X a = a DISC-P Smoke Detector z� x o.aQOS� = o.a���� FIRE ALARM WIRE IYPE CHART t71sC-fi Heat ��tectar 11 X 0.0f7075 = D.�D825 Label Description Wire Type sounder B�ses 5 x O.00D3 = 0.0[]18 AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) AB-42SK1 Manual �Pu�l Station 5 X �1.00Q6 = D.D03 J N � L Signaling Line Circuit #18 AWG Twisted Pair DXP-�CM Cantrol Module 1 X 0.00�6 - O.i]D06 Q J w Q t7XI'-PIM Monitor Mc�dule 1� K (].00D6 = D.DOE Z Q � J Z P 24VDC Power Wiring 2#14 AWG Solid C� � m Q C� � N Notification Appliance (Horn/Strobe) Wiring 2#14 AWG Solid S UM C�L�UM hl F�R STANDBY LOAD [1.1933 = AM PS � � J Z � � 0 P E RAT I 0 N S . � � Z z C� z Z z � X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid A l a r m N u m b e r o f C u r r e n t T a t a l C u r r e n t J � �'-� C� O N � � O O m Z Indicatin g Device Circuit (Zone) Wirin g 2#16 AWG Solid ❑evice Type aevices (prnps) (Amps} m J Z cn Q w a O ~ = U Base Panel 1 X 0.22 - 0.22 � m � g N m N N � w � w 1. ALL WIRING SHALL BE FPLP. Q CCR CommQn Cardi 1 X 0.0�9 = �.[J69 Q � � � � � � � N o 0 2. N O T-T A P P I N G P E R M I T T E D O N A N Y C I R C U I T � CIISC-P Smoke Detector 2� X D.DaD65 = 0.01365 � Q J g Z � Z � � � j j � . Z CIXP-AD2 Quct Detectar X O.OQ�S = Q QU J Z a � � � � � O p J � � m Z W A B-4 2 S K 1 Manua l Pu l l S ta tion 5 X D.0 0 0 6 = 0.(]4 3 �.l- Q � � � � � N � � Q � � O � px�-ocM co�,tr�u ��auie � x o.noa� = o.000s ,,, ,,, � � z � z � Z � ,,,., � � J D)(P-PIM Manitar Mrx4ule �a X (J.00D6 - �.D06 DEVICE a Q W cn o N o N o � m a Z O � NRC#1 1 X Q.993 = D.993 > > V Z � Z � Z � � � � �AC�� , ,� Q1� = Q,,� DESCRIPTION � � � o � o � � � PROJECT INFORMATION : Q C7utside RIV � x o.�08 = o.4�s a Q � ~ ~ ~ ~ � ° a `n a Z VA I L FI R E S TA TI 0 N R E M 0 D E L -� U z SUM GdLUMN FaR STI�NDBY LOAD �.�s��� _ ��P� i 42 WEST M EADOW DRI VE VAI L � J Q Standby�L_oa�d � ��quir�d sta�dt�y Tme in �aurs MANUAL PULL STATIONS X X X F I R E A L A R M S Y S T E M � � > c= Current Am s Q.1933 X 24 = �.�i4 � _ Alarm Load Required Alarm TEme in Hours SMOKE DETECTOR �( �( �( w w Q Current [Amps} �� minutes) APPLICABLE CODES: 2009 IBC, 2009 IFC, 2010 NFPA 72 � � 1.8715 X a.ns� = o.�s USE: FIRE STATION N � � �dc� s`and#�y and Alarm Laad far Required HEAT DETECTOR X X X FIRE SUPPRESSION: FULLY SPRINKLERED � � � � Ampere Hour 6attery 4.79 � Multipfy by the C]erating Factor of 1.2 z � �- w Total Ampere Maurs Required = 5.75 Batteries Provided: Minir�ur�n 7AH CARBON MONOXIDE DETECTOR X X X SCOPE OF WORK: NEW FIRE ALARM SYSTEM. WORK INCLUDES: � � � � Q Q � � • NEW ADDRESSABLE AS-BUILT FACP WITH DIALER AND BATTERY I- w c� m WATERFLOW SWITCH X X X X BACKUP � � � 0 • ADDRESSABLE SMOKE AND HEAT DETECTORS THROUGHOUT W • SMOKE DETECTORS WITH SOUNDER BASES IN RESIDENTIAL AREA � � � Z VALVE TAMPER SWITCH X X • MANUAL PULL STATIONS AT EXITS � w Q � • OCCUPANT NOTIFICATION THROUGH HORN/STROBES J � W � AC POWER LOSS X X � OUTSIDE HORN/STROBE Q N � WQ SPRINKLER SYSTEM SUPERVISION � � SHEET DESCRIPTION: GROUND FAULT X X COVER SHEET OPEN CIRCUIT/SHORT CIRCUIT X X DRAWN BY: DATE: D LS 9/26/12 SMOKE DETECTOR - EHU UNIT X X X SHEET#: FA-00 Z O N d � U � w � � O O � 0 j J W AD�RESS ❑�VICE T1'PE DEVICE DESCftIPTfON m � Q1 SMOKE DETECTf]R MALL 923 = i72 SMQKE DETECTDR ENTR'Y 120 w v3 SMOKE DETECTOR STORAGE 128 MOUNT EXTERIOR HORN/STROBE �* 04 MA�JURL PULL STATI�N ENTRY 120 •- �•QM 42 MAIN WATERFLOW ABOVE FIRE DEPARTMENT o �5 SMaKE aETECTC3R 1VIEN 113 CONNECTION. FIELD COORDINATE � o� HE,ar a���crQ� JAN 115 }�, �M 43 BACKFLOW TAMPER #1 WITH FIRE PROTECTION � �7 MONfTaR M�D�JLE PRV TAhJIPER SWITCH CONTRACTOR. USE ADDRESSABLE oa SMOKE �ETECTOR WOMEN 114 � �M 44 BACKFLOW TAMPER #2 SIGNAL MODULE TO CONVERT 24X a9 H�EATQETECTC�R APP,A,RATUS 124 } * AUX POWER TO 4 WIRE NAC CIRCUIT FOR CONTROL OF OUTSIDE m w 'P(] SN1C?K� �€TECTOR C7�FIC� 125 � �- 1� SMOKE DETECTQR C}FFICE 110 --�--�M45 MAIN LEVEL SPRINKLER WATERFLOW HORN/STROBE. N o 12 MANUAL PI�LL STATIQN WESTSTAIR 122 � WP 13 SMOKE DETECTOR IT 127 } � QM 46 MAIN LEVEL TAMPER SWITCH STORAGE 14 SA11f�KE �ETECTQR T�ILET 11'l 128 � O 15 H�EAT DETE�TOR APPAFtATUS 124 �M 47 UPPER LEVEL SPRINKLER WATERFLOW 16 MANUAL PULL STATI�N APPARATUS 124 r ~ - � MECHANICAL 17 HEATD�TECTC3� APPAR�,TUS 124 � _ 211 �M 48 UPPER LEVEL TAMPER SWITCH 03 F I NoRTH sTaiR � � 18 HEATD�TECTOR APPARATU5124 ` ' SM ? 15cd ENTRY � � 'f9 H�ATDETECTC7F2 RPPAF�ATUS 124 STAIR 04 120 I � 1 210 p� � 20 MANUAL PLVLL STATI�N WESTSTAIR 226 � �21 ' 25 � � 24V L I � � STUDIO/LIVING _ � � 21 �MQKE DETECTOR EHU �EDRDOkU'I 242 � I� 22 SMQKE DETECTDR EHIJ HALLWFIY 233 N--N I 229 � � �I I i O 23 MCJNITCIR M�dULE EHLI STUDI� ��9 CC) D�T�CTC}R � 022 ( � MEN I CO23 � F � � � OFFI E 24 SMOKE ❑ETECTOR EHU STUDID 229 I 110 HOSE DRY HALL � 113 WOMEN �� L ,� � 26 L LIVING � � 25 H�AT DETECT�OR M ECHANICAL 211 � �12 � � 15cd 0 24V 24 g 225 � � o 2& M A N L I�L P t J L L S T A T I�7 N N D R T H S T A I R 2 1[} I 5 — I 27 SMC3KE Wl50UNDER LIVING RM �25 � � 08 �, KIT 2HEN lo FROM FACP � �� � t � 28 MQNI��R M{7Dl7LE LIVING �M CO DE�ECTOR � ? J- " I � 1 M 2 I � � 28 2� � � 29 HEATDETECTOR KITCHEN 224 � » / Ol � D �� 06 I 1 M ? SB � 3(l SMOKE QETECTQR STORAGE 212 I \ 2 � I� N o 15cd I � P � L 29 �p 31 H�EAT�ETE�TOF� TOILET 216 \ �� � I g� STORAGE � • 32 SMQKE ❑ETECTC?R STORAG� 218 I ,. . � ' - - ------ '� 212 . � � 33 SMOKE WlSGU�fDER BEQRDaM 219 WESTSTAIR � 09 I 3 UTILITY P I �2 122 110Cd L WEST STAI 1 HALL 215 � 34 SMOKE W1S�JUNdER BE�R�DQM 22t1 0 ? l I J 35 sMOK� w�sour�o€� B��R��M 221 10 - p 226 P E � L 214 `1 36 MQNITi�R MCC}DULE HALL 223 CC7 QETECTO� L I.T. OFFICE JAN I 213 — �� 37 51111�KE WlSOUN��I� HALL 223 127 125 115 I W/D � o p2Rpp� � � 38 H�AT��TECTOR UTVLITY' 215 '' i � N 235 38 0 39 HI�A�C����C�OR �DILE�2'i7 2 I 0 - 022 '�a L 4Q SM�KE WlS�UhIaER BEDR�DM 222 �3 L TOILET I HALL 2 1 1 9 ? $B � 41 SIGNAL MCI�ULE �L1TSIf�E AN � 0 5 111 L I 233 2� F SM OM3 � 31 TOILET � 42 MON�TCJR M�DULE MAIN WATERFLJ4V 052 I�I � � 217 43 MC)NITOR M�DULE SPRINKLER TAMPER I - o I ,. � � � � T ABOVE � � a_ , p • � 44 MOhJfTOR MOQULE SPRINKLER TAMPER I � ? 32 37 M 36 � � O 45 MCJNIT�R MC�DULE Mf�l�l LEVEL WATERFLflW I I �ON I � CO SB EOLR � � � O5O SB CO HALL 46 MONIT�R MOQIJLE MAI�J L�VEL TAMPER I ��9 I 051 � O 47 M{�NITOR MC]DULE IJPPER LEIIEL WATERFLaW I I 1 APPARATUS l L 24V 24V � p 223 , Q 48 IVIONITdf� M4DULE IJPPER L�VEL TA��IPER I 124 2 P ? P 2 49 SMC7KE DETECT�DR EHU BE�ROOM 239 I 19 � 15 FROM Sg � Sg � Sg _ � r� O �o SIU1CDKE DETEC7dR EHU �r��ri�v� 2�� � I BELOW p 33 34 35 0 0 a 1 M{7 N I T�R M{7 C ti l�L E E H U L I V I N G 2 4 4 C O i D�T E C T O R I AIR FILL S TATION 2BR/LI ING � o BEDROOM � � U 52 SIGNAL MC��ULE EHU �JQRTFf 4JNIT SUUN�ER BASES ��$ 24 � BEDROOM BEDROOM X � 220 � p O N o 219 221 m � 53 SIGNAL MC3CDU�E EHU 5DUT9-i UiVIT SmIJI�DER BASES I L 54 I � r��j WORK/TOOI�S O � � � �j� I 117 I TOILET �� I STORAGE 216 �$ I 218 HALL �9 EMERGEN�Y 2 � � 049 6D I GENERAT R l 18 L � l O2� � i�i � SB �� I 116 �2 I 110Cd BEDROOM BEDROOM — 63 EOLR � 16 F 2a2 P 239 s� �_ I — �s 66 �� SCOPE OF WORK o 6g SEQUENCE NOTE: EHU SMOKE DETECTORS � �� SHALL BE PROGRAMMED AS SUPERVISORY AND Q . 71 SHALL SOUND A LOCAL ALARM THROUGHOUT � LLJ 72 THE UNIT ONLY. GENERAL ALARM IN THE - 73 BUILDING WILL ACTIVATE ALL SOUNDER BASES � 0— �4 THROUGHOUT BUILDING. O 75 � �� � OWER � EVE �. � � OOR P �. AN UPPER � EVE � � � OOR PL. AN J " z �� w J �S SCALE: 1/8" = 1'-0" PLAN SCALE: 1/8" = 1'-0" PLAN � Q = �� NORTH NORTH � � � 8C1 81 w � Q 82 � � 83 — 8� N � O ss � � � m ss z � I— w 87 Q 88 O Q � 90 Q a � �- 91 � uJ � m 92 � � � Q 94 � ~ � z 95 �-l- w Q � 9� s�r J � W � ss Q N � W ss � d- L.L 0 10D SHEET DESCRIPTION: FLOOR PLANS DRAWN BY: DATE: D LS 9/26/12 SHEET#: FA-01