HomeMy WebLinkAboutM07-0050'OWN OF VAIL
5 S. FRONTAGE ROAD
'AIL, CO 81657
70-479-2138
NOTE
Job Address:
Location.....:
Parcel No...:
Legal Description:
Project No :
DEPARTMENT OF COMMUNITY DEVELOPMENT
THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT
1722 ALPINE DR VAIL
1772 ALPINE DR.
210312312051
,'�-� �'.� <j `� - 6 �� `1 �i
JWNER DANTAS BUILDERS INC
PO BOX 4015
AVON
CO 81620
APPLICANT DIVIDED SKY P& H LLC
111 E. 15TH STREET
LEADVILLE
COLORADO 80461
License: 321-M
CONTRACTOR DIVIDED SKY P& H LLC
111 E. 15TH STREET
LEADVILLE
COLORADO 80461
License: 321-M
04/16/2007
04/16/2007
04/16/2007
Permit #: M07-0050
,.���--6 (�lt `"�� - CU(S�v
Status . . . : ISSUED
Applied . . : 04/ 16/2007
Issued . . . 04/24/2007
Expires . .: 10/21/2007
Phone: (719) 486-1934
Phone: (719) 486-1934
Desciption: INSTALL INFLOOR HEAT FOR 4200 SF; APPROX 1000 SF FOR
SNOWMELT; FIREPLACE VENTING BY OTHERS; BOILERS ARE SEALED
COMBUSTION
Valuation: $17,500.00
Fireplace Information: Resaicted: # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0
****�************�****�****�:**********************�***************** FEE SUMMARY *****�********�**�******************************************
o. oo Total Calculated Fees---> $453 . o0
Mechanical---> $360. 00 Restuarant Plan Review-- ; 453 . 00 Additional Fees-----------> $0. 00
Plan Check---> $90. 00 TOTAL FEES------------- $ Total Permit Fee----------> $453 . 00
Invesagation-> $ o. o 0 4 5 3. 0 0
Will Cal]----> $3 - �o Payments-------------------> $
BALANCE DUE---------> $ o. o 0
******�**********�:********�********�:***********�************�:****************�:******************�*****************�*****�**********�**�***���****
Item: 05100 BUILDING DEPARTMENT
04/16/2007 cgunion Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR
304 OF THE 2003 IFGC AS
Cond: 23
IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION
MODIFIED BY TOWN OF VAIL.
(BLDG.): BOIILER INSTALLATION MUST CONFORM
CHAPTER 10 OF THE 2003 IMC.
TO MANUFACTURER'S INSTRUCTIONS AND
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.
Cond: 29
BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
MC AND CHAPTER 3 OF THE 2003 IFGC..
ond : 31
BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
�ISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
'ond : 3 2
BLDG.): PERMIT,PLA.NS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
'O AN INSPECTION REQUEST.
'ond : 3 0
'BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
1EANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
**�*****�************************�:**********************************************************�*****************************�*********************
DECLARATIONS
hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
�lan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
Nith all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
�eview approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
3EQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV
�M. �=`'�
79-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
SIGNA E OF ER OR CONTRACTOR FOR HIMS�;Lr Aiv1� uwi��r
*****************�*****�*�***�*�**��***�***���**�*�*��**�**********�*�**���**��**�****�****�
TOWN OF VAIL, COLORADO Statement
*��********�*:x*********�*****�:x�x�x****�:**�*****�:**********�:�**�**********�:*****�:******�:*****�:
Statement
Payment
Number: R070000543 Amount: $453.00 04/24/200702:57 PM
Method: Check Init: DDG
Notation: Divided Sky P &
H 1318
---------------------------------------------
Permit No:
Parcel No:
Site Address:
t'
M07-0050
2103-123-1205-1
1722 ALPINE DR
1772 ALPINE DR.
Type
VAIL
MECHANICAL PERMIT
Loca ion. 453.00
Total Fees: $
This Payment: $453.00 Total ALL Pmts: $453.00
Balance: $0.00
**+************************�*************�**********��**+�:****:x*��x***:x*******:x******�:*****��:
ACCOUNT ITEM LIST:
Account Code
--------------------
MP 00100003111100
PF 00100003112300
WC 00100003112800
Description
------------------------------
MECHANICAL PERMIT FEES
PLAN CHECK FEES
WILL CALL INSPECTION FEE
--------------------------------------------
Current Pmts
360.00
90.00
3.00
�' �
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN /J (
TOV Project #: �-�
Building Permit #:
� Mechanical Permit #:
970-479-2149 (Inspectii
75 S. Frontage Rd.
Vail, Colorado 81657
Permit will not be accepted without the following:
Provide Mechanical Room Layout drawn to scale to include:
e� Mechanical Room Dimensions
� Combustion Air Duct Size and Location
� Flue, Vent and Gas Line Size and Location
� Heat Loss Calcs.
�- Equipment Cut/Spec Sheets
Mechanical Contractor: ,
a�v�oe� sM-*j P��M���, � H�r�G,
E-Mail Address:
Contractor Signature: ,�j,
��
CONTRACTOR INFORMATION
Town of Vail Reg. No.: Contact Person and Phone� 's� l� ����
3�1 _ ,�n 82��,� irOA�c. �q o
Fax#:
v �
COMPLETE VALUATION FOR MECHANICAL PERMIT
MECHANICAL: $ � % , SD�
Contact E
Pa______
Job Name:
�/e County Assessors O�ce at 970-3�
,�IC'3/Z.3iz OS/
�,v��s ��oF�� !�r � 1�
Legal Description
Owners Name: �r
Engineer:
Lot: 1�
�A��Ti°S
Block: Filing:
� Address:
Address:
or visit
r & Materials
for Parce/ #
Job Address: I►,r'� ��„�� D�=
� Subdivision: ��t� V uu.A�� �✓Gs �
Phone: �� .- S�ycf
Phone:
,�
" �'�TiM�, �/ o Tr�c-+�..5
Detailed description of work: 'Y��� ��'r �� `�� �� �'�p�`�
flPI>�e,c. 1�9(? �a,�r Fo2 S�.mw.,�►� �/tc.,�s � s� �m3��-�0�,/
Work Class: New � Addition ( ) Alteration ( ) Repair ( ) Other ( )
Boiler Location: Interior (� Exterior () Other () Does an EHU exist at this location: Yes () No ()
Type of Bldg• Single-family (x) Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building: No. of Accomm��ati�n Units m this building.
No/Type of Fireplaces Existing Gas Appliances () Gas Logs () Wood/Pellet () Wood Burning ()
No/Type of Fireplaces Proposed: Gas Appliances (� Gas Logs () Wood/Pellet () Wood Burning (NOT ALLOWED)
Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes () No (
************************FOR OFFICE USE ONLY*****************************
(„��"� f�ther �ees: ., , Date Received: .
,
L_J A 4
F:\cdev\FORMS\PERMITS\Buildi ng\mechanical�ermit_l i-23-2005. DOC