Loading...
HomeMy WebLinkAboutDRB130020 Approved PlansBy David Rhoades at 11:58 am, Feb 06, 2013 XXXXXXXXXXXXXXXXXXXXX CHANGE TO APPROVED PLANS Property Address    Parcel #    Legal DescripƟon    Development Site Area sq Ō   acres   buildable sq  Ō     Zone District / SDD #    Hazard Zones  SecƟons 12‐21 & 14‐7  Snow Avalanche     High Severity      Moderate Severity      N/A  Debris Flow     High Flow            Moderate Flow            High Avalanche            N/A  Rock fall     High Severity      Medium Severity        N/A  Excessive Slopes     ≥30%                    N/A  Floodplain     100 year floodplain            Floodway            Wetlands               N/A  Creeks, Streams  SecƟon 12‐14‐17      Gore Creek        on site          adjacent to site           N/A      Other tributary: ______________         on site         adjacent to site                 N/A  Project DescripƟon    Development Standards   Allowed ExisƟng Proposed  Gross ResidenƟal Floor Area  (maximum)  Chapter 12‐15  Primary sq Ō       Secondary sq Ō        EHU sq Ō        TOTAL sq Ō          250 AddiƟon              Interior Conversion  Credits:  Setbacks (minimum)  SecƟon 14‐10‐4  Front Ō        Side Ō        Side Ō        Rear Ō        Watercourse Ō        Site Coverage (maximum)  see definiƟon SecƟon 12‐2‐2           Building Height (maximum)  see definiƟon SecƟon 12‐2‐2  Sloping Ō  Flat Ō         Landscaping  See definiƟon SecƟon 14‐2‐1  SecƟon 14‐10‐8  SoŌscape sq Ō        Hardscape sq Ō        TOTAL sq Ō        Driveway  SecƟons 14‐3‐1 & 14‐3‐2     Max Curb‐cuts        Max Grade @ cen‐ terline         Min Width        Heated drive?        Yes          No      Yes          No  Snow Storage %        Parking  SecƟons 12‐10 & 14‐5  #Enclosed Spaces  #Unenclosed  TOTAL         Outdoor LighƟng (maximum)  SecƟon 14‐10‐7  # fixtures        Property Information Project Information 1116 Sandstone Drive, Unit 701, Vail, CO 2103-014-10-015 Window Replacement   PROPOSED MATERIALS Notes: Please specify the manufacturer’s name, the color name and number and attach a color chip. Building Materials         Roof  .   .  Siding  .   .  Other Wall Materials  .   .  Fascia  .   .  Soffits  .   .  Windows  .   .  Window Trim  .   .  Doors  .   .  Door Trim  .   .  Hand or Deck Rails  .   .  Flues  .   .  Flashing  .   .  Chimneys  .   .  Trash Enclosures  .   .  Greenhouses  .   .  Retaining Walls  .   .  Exterior Lighting  .   .  Other  .   .  Building Materials  Type of Material Color         Roof  .   .  Siding  .   .  Other Wall Materials  .   .  Fascia  .   .  Soffits  .   .  Windows  .   .  Window Trim  .   .  Doors  .   .  Door Trim  .   .  Hand or Deck Rails  .   .  Flues  .   .  Flashing  .   .  Chimneys  .   .  Trash Enclosures  .   .  Greenhouses  .   .  Retaining Walls  .   .  Exterior Lighting  .   .  Other  .   .  Jeld-Wen Wood Clad Painted to matchexisting 51 Eagle Road #2 P O Drawer 5400 Avon, Colorado 81620 t. 970.949.5152 f. 970.949.4379 www.ranelson.com Creating opportunities and building lasting relationships since 1976. 1116 Sandstone Drive Remodel Lions Mane Condo Unit 701 Vail, CO Phase II - Renovation Scope of Work 2/5/2013 Design Review Board, This DRB submittal is for window replacement/additions for phase II of this remodel at unit 701. Window replacement was approved for phase I of this project under the DRB # DRB120588 and building permit # B12-0632. Approved phase I of this renovation included window replacement and an interior renovation of the main and second level. Phase II will consist of window replacement and an interior renovation of the third level. No square footage will be added nor will there be any modifications to the exterior other than replacing existing or adding new windows. The windows appear to be from the original construction in 1970 and are in need of replacement as they are old and inefficient. The existing windows are all wood construction with a paint exterior cladding. The new proposed windows will be supplied by Jeld-Wen to meet the current Town of Vail u- value and energy code requirements. The windows will be constructed as all wood and the exterior wood clad will be painted the match the existing window color. Any wood trim or stucco that will need to be removed during the installation will be replaced in its exact original condition and color. North Elevation: There are currently 3 operable windows at the third floor of the North elevation. These windows are 21-1/4” x 44-1/2” and are separated by a 1’ mullion (overall assembly dimension of 87-1/2” x 44-1/2”). This window assembly is about 17” off the East exterior wall corner. New windows will be installed in a similar configuration. As these windows will need to be egress, they will have to be a minimum of 28” wide. The replacement will consist of (3) 28”x44” operable casement windows, mulled together which will eliminate the existing vertical mullions. The new window opening will be very similar to the existing at 84” x 44”. This opening will be shifted 5” to the east to center in the new bedroom configuration. The sill elevation of 33” off the finished floor will remain. A new stucco band will be installed around the perimeter of the opening to match the existing. Stucco will be repaired and painted to match existing conditions. This window assembly will match the configuration of the adjacent unit 601. West Elevation: There are currently no windows on this elevation. 2 new openings will be created for 2 new 24”x48” operable casement windows. As there is a sloped roof for the adjacent unit, the North window will be installed at a sill height of 36” and the south window By David Rhoades at 12:00 pm, Feb 06, 2013 Creating opportunities and building lasting relationships since 1976. will be installed at 60” as it will need to be higher to clear the sloped roof. Both windows will be installed about 24” above the adjacent roof. A new stucco band will be installed around the perimeter of the windows to match existing conditions. South Elevation: There is currently (1) 24”x72” casement window located at the stair landing, 60” off the finished floor. Most of the other units with a 3rd level have added windows at this elevation and we are proposing a configuration that will match the others. (3) new 35”x84” windows will be installed in the stairway at a sill elevation of 48” off finished floor, separated by a 7” mullion. The two outer windows will be operable casements and the center window will be fixed. (1) 46”x36” operable awning window will be installed in the shower at 60” off finished floor. A new stucco band will be installed around the perimeter of the windows to match existing conditions. These new window will have a wood clad exterior that will be painted to match the color of the existing wood windows. Included in this application are floor plans indicating the extent of this renovation and pictures of the exterior of this condo building. Should you need any additional information for approval, please don’t hesitate to contact me. Thank you for your time and consideration. Jason Morley LEED® AP 970-748-5280 Office 970-949-4379 Fax 970-471-3919 Cell jmorley@ranelson.com R.A. Nelson 51 Eagle Road #2 P.O. Drawer 5400 Avon, CO 81620 970.949.5152 NORTHELEVATION ExistingCondition: 3windows(21-1/4"x44-1/2")operablewith 12"millionsbetweenwindows.Sillheight setat33"offfloor. 87-1/2"frametoframe NewCondition: Replace3existingwindows.Windowswill beoperablecasementsandthewidthwill needtobeincreasedto28"tomeetegress coderequirements.(3)28"x44"casement windowswillbemulledtogether.Thesill& headheightelevationwillremainthesame andtheverticalmullionswillberemoved. Theoverallopeningwidthwillbedecreased byabout3"andmovedtotheEastbyabout 5".Thiswillmatchtheadjacentunit.Stucco bandwillbereplacedtomatchexisting condition Approx.84"frametoframe 17" 12" Design Review Staff Approval By Warren Campbell at 4:11 pm, Feb 14, 2013 WESTELEVATION ExistingConditions: Nowindowsonthewest elevation. NewCondition: Add(2)new24"x48" casementwindows. Referencefloorplanfor locations.Windowsill heightstoslopewith adjacentroof. 36"SillHeight 60"SillHeight Design Review Staff Approval By Warren Campbell at 4:11 pm, Feb 14, 2013 SOUTHELEVATION ExistingConditions: (1)24"x72"casementwindowwith60" sillelevation NewCondition (3)35"x84"windowsatstairs.Two outsidewindowsareoperable casementsandcenterwindowis fixed.Sillelevationof48" (1)46"x36"awningwindowat showerwithasillelevationof60" Built up stucco trim band to bridge the distance between each window. Design Review Staff Approval By Warren Campbell at 4:11 pm, Feb 14, 2013 SOUTH ELEVATION – Similar Exterior Conditions          Unit 301 has installed new windows and is the model for our new south elevation. They has 3 large 35"x90" windows in the stairwell and at 46"x30" awning in the shower. Unit 601 has installed three large windows in the stairwell similar to the configuration that we are proposing. 3' - 0 " 5' - 0 " 4' - 0" 3' - 6" 21 21 13 13 13 34 34 34 4' - 10" 2' - 0 " 23' - 2 15/32" 8' - 0 " 0' - 6 " 0' - 6 " (3 ) n e w c a s e m e n t w i n d o w s . 2 8 " x 4 4 " m u l l e d t o g e t h e r . Si l l h i e g h t a t 3 3 " t o m a t c h e x i s t i n g . 0' - 6"0' - 6" 3' - 0 9/16"3' - 0 1/2" Sl i d i n g g l a s s s h o w e r d o o r s 5' - 10 3/16"5' - 0 9/16" 0' - 7 " 0' - 7 " 0' - 7 1 / 4 " 0' - 7 5 / 1 6 " 24 " x 4 8 " c a s e m e n t w i n d o w . 36 " s i l l h e i g h t . T e m p e r e d 24 " x 4 8 " c a s e m e n t w i n d o w . 60 " s i l l h e i g h t . T e m p e r e d 46 " x 3 6 " A w n i n g w i n d o w - t e m p e r e d 60 " s i l l h e i g h t 35 " x 8 4 " C a s e m e n t Te m p e r e d 35 " x 8 4 " C a s e m e n t Te m p e r e d 35 " x 8 4 " F i x e d Te m p e r e d To p o f w a l l a t 4 2 " To p o f w a l l a t 4 6 " To p o f w a l l a t 5 0 " To p o f w a l l a t 6 0 " w / 2' t a l l c l e a r g l a s s p a n e l ScaleDateDrawn byOwner: Lou & Michelle Bainbridge Address: 1116 Sandstone Drive - Unit 701 Vail, CO 81657 General Contractor: R.A. Nelson, LLC Contact: Jason Morley Address: 51 Eagle Rd. / PO Drawer 5400 Avon, CO 81620 Phone: (970) 949-5152 Fax: (970) 949-4379 e-mail: jmorley@ranelson.comBainbridge Remodel Lions Main Unit 701 Bainbridge Remodel As indicatedA1033rd Level - EL 8270' 1 / 2 " = 1 ' - 0 " 1 3r d L e v e l No.DescriptionDate 1 2 " = 1 ' - 0 " 2 SW C o r n e r TV N i t c h Ge n e r a l No t e s : -F l o a t ex i s t i n g fl o o r s ar e required for new wood flooring & ti l e . -I n s t a l l ne w Je l d - W e n windows. Stain interior to match mi l l w o r k an d pa i n t ex t e r i o r to match existing paint color. -I n s t a l l ne w wo o d fl o o r i n g to match phase 1 -I n s t a l l ti l e fl o o r s , sh o w e r floors and shower surround (8') to ma t c h ph a s e I la y o u t and materials. -I n s t a l l wo o d wa l l ca p at half walls. -I n s t a l l ba r n do o r ha r d w a r e on closet door. -I n s t a l l fr a m e d TV ni c h e with drywall & adjustable wood sh e l v e s . -P a t c h dr y w a l l an d ap p l y new drywall texture throughout. 1DRB Submittal2.5.13 By David Rhoades at 11:59 am, Feb 06, 2013 De s i g n R e v i e w St a f f A p p r o v a l By Wa r r e n Ca m p b e l l at 4:12 pm, Feb 14, 2013