Loading...
HomeMy WebLinkAboutB06-0194TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT SFR BUILD PERMIT Permit #: B06-0194 Project # PRJ06-0249 Job Address: 2950 BOOTH CREEK DR VAIL Status ...: ISSUED Location.....: 2950 BOOTH CREEK DR Applied ..: 07/13/2006 Parcel No...: 210103405007 Issued ... : 08/04/2006 Expires . ..: O1/31/2007 OWNER BOOTH CREEK DRIVE, LLC 4310 77TH ST VERO BEACH FL 32967 ARCHITECT BETH LEVINE, ARCHITECT P.O. BOX 1825 AVPM CO 81620 License: C000001399 APPLICANT NEDBO CONSTRUCTION P.O. BOX 3419 VAIL CO 81658 License: 251-A CONTRACTOR NEDBO CONSTRUCTION P.O. BOX 3419 VAIL CO 81658 License: 251-A 07/19/2006 07/19/2006 07/19/2006 07/19/2006 Phone: 970-926-5099 Phone: 970-845-1001 Phone: 970-845-1001 Description: REMOVE FIREPLACE; ADD WINDOWS; RELOCATE WINDOW IN BATH. COMBINE 2 BEDROOMS INTO MASTER BEDROOM AND BATH. RECONFIGUR.E LOWER LEVEL BEDROOM. NON BEARING INTERIOR WALLS Occupancy: R-3 Type Construction: V-B Valuation: $75,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 *****************�*********�**************************************** FEE SUMMARY ***********************�*******************�**************** Building-------> $818.75 Restuarant Plan Review--> $0.00 Total Calculated Fees--> $1,353.94 Plan Check----> $532.19 Recreation Fee--------------> $0.00 Additional Fees----------> $0.00 Investigation--> $0.00 TOTAL FEES--------------> $1,353.94 Total Pernut Fee--------> $1,353.94 Will Call------> $3.00 Payments-----------------> $1,353.94 BALANCE DUE-------> $0.00 ***�*****************************************************�*****************************************�********************�*****************+****** Approvals: Item: 05100 BUILDING DEPARTMENT 08/03/2006 cgunion Action: AP Item: 05400 PLANNING DEPARTMENT 07/20/2006 WARREN Action: COND SEE CONDITION REGARDING REPLACMENT OF THE ILLEGAL LIGHT FIXTURES EXISTING ON THE STRUCTURE. ***���***�**�*�**��*����*�*���**�*��*��**�**�*����*****��***���**�****�**�������**����*���*��*�*��*��*�* CONDITIONS OF APPROVAL Permit #: B06-0194 as of 08-04-2006 Status: ISSUED �*�**�:*��*��*�x*=�**�x**�:*�*�**��x**�x�:*�����x*��:**�:*�x�x*�x***:�*x����x*:x****�x*:x**���:*�:*�:***�:**����:*�*��x*�x**�:***�*� Permit Type: ADD/ALT SFR BUILD PERMIT Applicant: NEDBO CONSTRUCTION 970-845-1001 Job Address: 2950 BOOTH CREEK DR VAIL Location: 2950 BOOTH CREEK DR Parcel No: 210103405007 Applied: 07/ 13/2006 Issued: 08/04/2006 To Expire: O1/31/2007 Description: REMOVE FIREPLACE; ADD WINDOWS; RELOCATE WINDOW IN BATH. COMBINE 2 BEDROOMS INTO MASTER BEDROOM AND BATH. RECONFIGURE LOWER LEVEL BEDROOM. NON BEARING INTERIOR WALLS �x*����x*��:**�**:x�*��******�x*�*��x*�x*�x*��x�****�*�**�* Conditions *****�x*�*����*�:�*��x�x*�:x**�x=x�x�x*�x��x����x*�x*��** Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. Cond: CON0008281 CONTACT FIRE DEPARTMENT PRIOR TO COMMENCING WORK. Cond: CON0008295 The applicant shall submit to staff for review and approval a replacement light fixture which complies with the TOV lighting standards to replace all the flood light fixtures on the home. This shall be completed prior to requesting a certi�icate of occupancy. Cond: CON0008328 TRUTURAL ENGINEER SHALL REVIEW AND PROVIDE PLANS FOR FRAMING OF NEW 12" BALCONY IF STRUCTURAL JOISTS ARE ADDED OR ALTERED, ANY INTERIOR STRUCTURAL WORK AND ROOF FRAMING WHERE FIREPLACE IS REMOVED. Item: 05600 FIRE DEPARTMENT 07/19/2006 MVAUGHAN Action: AP CONTACT FIRE DEPARTMENT PRIOR TO COMMENCING ANY ACTIVITY. �*********�*��**********�***********************�+***************�***********�********************�**************************�*****�************* See the Conditions section of this Document for any that may apply. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 5:00 AM - 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER 4 ***********:k#**##*#***#**�k*###*****##**#*****#**#�k###*�k�k**#*#***#�k�k***#**�k�k#�k�k�k*#�k#****###*# TOWN OF VAIL, COLORADO Statement **�+�x***�************:x********�************************�:�******************�**************** Statement Number: R060001156 Amount: $528.94 OS/04/200609:35 AM Payment Method: Check Init: LT Notation: Nedbo / ck30095 ----------------------------------------------------------------------------- Permit No: B06-0194 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2101-034-0500-7 Site Address: 2950 BOOTH CREEK DR VAIL Location: 2950 BOOTH CREEK DR Total Fees: $1,353.94 This Payment: $528.94 Total ALL Pmts: $1,353.94 Balance: $0.00 ********************************************************�****************�x********�:*�**:x**** ACCOUNT ITEM LIST: Account Code BP 00100003111100 WC 00100003112800 Description BUILDING FERMIT FEES WILL CALL INSPECTION FEE Current Pmts 525.94 3.00 ----------------------------------------------------------------------------- .w. ��. ��t� Vi Tt..,,,} 1 � 75 S. Frontage Rd. Vail, Colorado 81657 0 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG��G--(�Z�� Project #: � ' �� Building Permit #: J7U-479-2949 {Inspectioiis) TOWN OF VAIL BUILDING PERMIT AQPLICATION '-�1 Separate Permits are required for electrical, pluml�ing, mechanical, etc.! �� �U� i t� �U�[� , I� CONTRACTOR INFORMATION y ; ' �;? General Contractor: Town of Vail Reg. No.: ContacC Person and Phone #'s: �%f,+O c�d Ca.-u,Syfi2 dc.i/OV / � %�I oCG/F ? % —D.?6}'� _ Email address: a��� ��s,�,av ,��„�,� Fax #: �,lj � cc� 7 Contractor Signature: ,/ / ` .r � �1 - �`� � ��y; ,� ' COMPLET� VALUATIONS FOR BUILDING PERMIT (Labor 8� Materials) BUILDING: $ �� �qp , pv ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ TOTAL: $ %�p00, q, For Parcel # Confact Ea le Count Assessors O�ce at 970-328-8640 or visit www.ea !e-counf .com �arcei;# �/a/a 3 �'O,roo7 JobName: ��rN..v��� %�,�,yt�/J�"L JobAddress: �j0 %�vpTH C/�,�,e ,E.��r/Q Legal Description Lot: � Block: 3 Filing: // � Subdivision:(/,Cj/t. �//LL��� O�o�er7Name� ���v� �C Address: 3/0 7 �"��j� vit2v /,fr..�c�� �..�-�, Phone�72— — ArchitecUDesigner: N/� Address: Phone: Engineer: �v/n. Address: Phone: Detailed description of work: ���,,,� �,�� a�,��,e��„�J i•✓TU ,yt,�7,��C /��,�,�vo� .-�5•9�"'.� �E Cu �v N-/ G v2.� <o w?�2 ut d,t�nC.- ����o✓�� Work Class: New ( ) Addition ( ) Remodel � Repair ( ) Demo ( ) Other ( ) Work Type: Interior (x( Exterior () Both () Does an EHU exist at this location: Yes () No () Type of Bldg.: Single-family� Two-family () Multi-family () Commercial () Restaurant () Other () No. of Existing Dwelling Units in this building: � No. of Accommodation Units in this building: �' No/T pe of Fire laces Existin : Gas Ap liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes (>Q No () Does a Fire Sprinkler System Exist: Yes () No FOR OFFICE USE ONLY Type`of Construction ��j Date Received: . , � , ,� , �_ �_. Occupancy Group „r ,:, ,, ,, ,; .;� Accepted By: ' � �; [� � ; t.J ''p � �k#� �. � �006 I .':� a � � , f !"`" �" � 1 �: ! � ? F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 1 of 16 02/09/2005 � . ��'�� �F i�� " Questions? Call the Building Team at 479-2325 Buildinq Permit Submittal Checklist Department of Community Development Project Name: �N�t/`i/J! ��i�oi✓cL Project Address: o?�� a��T�� C��%ic G�� v� ✓ This Checklist must be completed before a Buildin4 Permit aaalication is accepted. ,� All pages of application is complete ❑ Has DRB approval obtained (if required) Provide a copy of approval form ❑ Plan Check Fee required at submittal for projects valued over $100,000.00 (see attached fee schedule) ❑ Complete site plan submitted ❑ Public Way Permit application included if applicable (refer to Public Works checklist) ❑ Staging plan included (refer to Public Works checklist) No dumaster,�parkinq or material storaqe allowed on roadwavs and shoulders without written aparoval o Asbestos test and results submitted if demolition is occurring ❑ Architect stamp and signature (All Commercial and Multi family) ❑ Full floor plans including building sections and elevations(3 sets for remodels, 4 sets of plans for SFR and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings) ❑ Window and door schedule ❑ Full structural plans, including design criteria (i.e.loads) ❑ Structural Engineer stamp and signature on structural plans (All Commercial and Multi Family) ❑ Soils Report must be submitted prior to footing inspection ❑ Fire resistive assemblies specified and penetrations indicated ❑ Smoke detectors shown on plans ❑ Types and quantity of fireplaces shown " A licant's Si nature: /�-�`L'�/ '..� ---- PP 9 Date of submittal: Received By: � F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 2 of 16 02/09/2005 . �,. ��� �� ��,° � WHEN A"PUBLIC WAY PERMIT" IS REQUIRED 0 PLEASE READ AND CHECK OFF EACH OF THE FOLLOWING QUESTIONS REGARDING THE NEED FOR A "PUBLIC WAY PERMIT": o Is this a new residence? YES N0�_ o Does demolition work being performed require the use of the Right-of-Way, easements or public property? YES NO � o Is any utility work needed? YES NO � o Are there any improvements being done to the driveway? YES N0�_ o Is a different access needed to the site other than the existing driveway? YES. NO �C o Is any drainage work being done that affects the Right-of-Way, easements, or public property? YES N0�_ o Is a"Revocable Right-of-Way Permit" required? YES N0�_ o Is the Right-of-Way, easements or public property to be used for staging, parking or fencing? YES N0�_ If answer it NO, is � rking, staging or fencing plan required by Public Works? YES NO If you have answered YES to any of these questions, a"Public Way Permit" must be obtained. "Public Way PermiY' applications may be obtained at the Public Works office or at Community Development (a sample is attached). If you have any questions please call Leonard Sandoval in Public Works at 970-479-2198. I HAVE RE D AND ANSWER,�D AL�E ABOVE QUESTIONS. , , / �Z�+�>L�-'� � -' �F/J/�e CO-?/Yfit� �7la�Z� Contractor ' natu e Company Name i Job or Project Name: �� rl/�?/�2���2.vto�L Date Signed: /��,f�,G PRJ #: - F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 7 of 16 ,.." . ; , � How it relates to Building Permits: ➢ Fill out the attached check list with the Buildin�Permit Application. If yes was answered to any of the questions then a��Public Way" permit is required. You can pick up an application at either Community Development, located at 75 South Frontage Road or Public Works, located at 1309 Elkhorn Drive. ➢ Notice sign-offs for utility companies. ALL utilities must field verify (locate) respective utilities prior to signing application. Some utility companies require up to 48 hours notice to schedule a locate. ➢ A construction traffic control/staging plan must be prepared on a separate sheet of paper. An approved site plan may also be used. This plan will show locations of all traffic control devices (signs, cones, etc.) and the work zone, (area of construction, staging, etc.). This plan will expire on November 1�` and will need to be resubmitted for consideration for approval through the winter. Be aware that your resubmission for winter may be denied depending on the location of construction. ➢ Sketch of work being performed must be submitted indicating dimensions (length, width and depth of work). This may be drawn on the traffic control plan or a site plan for the job. ➢ Submit completed application to the Public Works office for review. If required, locates will be scheduled for the Town of Vail electricians and irrigation crew. The locates take place in the morning, but may require up to 48 hours to perform. ➢ The Public Works Construction Inspector will review the application and approve or deny the permit. You will be contacted as to the status and any requirements that may be needed. Most permits are released 48 hours of being received, but please allow up to one (1) week to process. ➢ As soon as the permit is approved, the Building Department will be notified, allowing the °Building Permit" to be released. Please do not confuse the "Public Way Permit" with the "Building Permit". ➢ NOTE: The above process is for work in a public way ONLY. Public Way Permits are valid only until November 15th. A new Public Way Permit is required each year if work is not complete. Re- application each November 15t'' does not mean an automatic renewal. I have read and under,�tan the above. ; � _ i� �'���--�� � !�. ���dL , Signature�� � Date Signed a.: ° � � ��'��'�� ���, , F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 9 of 16 OZ/09/2005 I�I �� �� � � � � MATERIAL STORAGE AND CONSTRUCTION PARKING Please read and check off each of the items below. (Copies of complete text are available upon request) CODE 5-2-10: DEPOSTTS ON PUBLIC WAYS PROHIBITED ❑ Unlawful deposits: Subject to subsection C thereof, it is untawful for any person to litter, track or deposit, or cause to be littered, tracked or deposited, sand, gravel, rocks, mud, dirt, snow, ice, or any other debris or material upon any street, sidewalk, alley or public place, or any portion thereof. ❑ Notice; Abatement: The Director of Public Works may notify and require any person who violates or causes another to violate the provision of subsection A hereof, or who has in the Director's employment a person who violates or causes another to violate the same, top remove such sand, gravel, rocks, mud, dirt, snow, ice or any other debris or material within twenty four (24) hours after receipt of said notice by the Director of Public Works. In the event the person so notified does not comply with the notice within the period of time herein specified, the Director of Public Works, or other authorized agent, may cause any such sand, gravel, rocks, mud, dirt, snow, ice, debris or any other material to be removed from any street or alley at the expense of the notified. ❑ Summons and Penalty: As an alternative to the notice for removal provided in subsection B above, any person who violates or causes another to violate the same, may be issued a summons to appear before the Municipal Court of the Town for said violations, and upon being found guilty of a violation hereunder be punished as provided in Section 1-4-1 of this code. ❑ Notice and Penalty: It is unlawful for any person to fail or refuse to comply with the notice of the Director of Public Works as provided in subsection B hereof, and any such person shall, in addition to payment of the expense of removal incurred by the Director of Public Works, as provided in subsection B hereof, upon being found guilty of a violation hereunder, be punishable as provided in Section 1-4-1 of this Code. (1997 Code: Ordinance 6(1979). CODES 7-3A-1 AND 7-3A-3: PARKING OBSTRUCTlNG TRAFFIC & IMPOUNDMENT AUTHORIZED ❑ No person shall park any vehicle upon a street or at any other place within this Municipality in such a manner or under such conditions as to interfere with the free movement of vehicular traffic or proper street or highway maintenance. (Ord. 2(1968) § 1) . . ❑ Whenever any police ofFicer finds a vehicle attended or unattended, standing upon any portion of a street or upon any place within this Municipality in such a manner as to constitute a violation of any section of this Article, or left unattended for a period of twenty four (24) hours or more and presumed to be abandoned under the conditions prescribed by Colorado Revised Statutes section 42-4-1102, as amended, the officer shall require the vehicle to be removed or cause it to be removed and placed in storage in the nearest garage or other place of safety designated or maintained by this Municipality, and the charges for towing and storage of such vehicle shall be charged to the owner of the vehicle in addition to a ten dollar ($10) impoundment charge. (Ord. 2(1968) § 3: Ord. 28(1981) § 1) I have read and will comply with the above code provisions: �oL�LI�t10 cT�/i�S' /�(� ' Print a � •��� gna re Position or Relationship to Project: ( 9�i't/�/1.�� U���� Date Signed: G r F:/everyone/forms/bldperm7 F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 11 of 16 02/09/2005 *****************************************�*****************�*�*******�********************** TOWN OF VAIL, COLORADO Statement ****************************+***************:�***********+*********************************** Statement Number: R060001018 Amount: $825.00 07/19/200608:27 AM Payment Method: Check Init: JS Notation: 29874/NEDBO CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B06-0194 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2101-034-0500-7 Site Address: 2950 BOOTH CREEK DR VAIL Location: 2950 BOOTH CREEK DR Total Fees: $1,353.94 This Payment: $825.00 Total ALL Pmts: $825.00 Balance: $528.94 ******************************************:�***********�x****�*******************************�x ACCOLJNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 Description Current Pmts ------------------------------ ------------ BUILDII3G PERMIT FEES 292.81 PLAN CHECK FEES 532.19 ----------------------------------------------------------------------------- 04-10-2012 Inspection Request Rep orting Page 3 9:38 am Vail,s'C� �i�v Of Requested Inspect Date: Thursday, April 12, 2012 Inspection Area: CG Site Address: 2950 BOOTH CREEK DR VAIL 2950 BOOTH CREEK DR AlP/D Information Activity: B06-0194 Type: A-BUILD Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: V-B Insp Area: CG Owner: BOOTH CREEK DRIVE, LLC Architect: BETH LEVINE, ARCHITECT Phone: 970-926-5099 Contractor: NEDBO CONSTRUCTION Phone: 970-845-1001 Description: REMOVE FIREPLACE; ADD WINDOWS� RELOCATE WINDOW IN BATH. COMBINE 2 BEDROOMS INTO MASTER BEDROOM AND BATH. RECONFIGURE LOWER LEVEL BEDROOM. NON BEARING INTERIOR WALLS Requested Inspection(s) Item: 90 BLDG-Final Requestor: NEDBO CONSTRUCTIOI Assigned To: JMONDRAGON Action: Inspection Historv Item: 501 PW-Access/Staging/Erosion Item: 30 BLDG-Framing �* Approved "' 09/18/06 Inspector: JRM Comment: Item: 50 BLDG-Insulation ** A� pproved ** 09/18/06 Inspector: JRM Comment: Item: 60 BLDG-Sheetrock Nail "" Approved "" 09/22/06 Inspector: JRM Comment: Item: 70 BLDG-Misc. Item: 533 PLAN-TEMP. C/O Item: 534 PLAN - FINAL C/O Item: 90 BLDG-Final Time Exr• Requested Time: 10:00 AM Phone: 970-845-1001 -or- 970-977- 0268 Rollie cell Entered By: JMONDRAGON K REPT131 Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Run Id: 14332 _ __.��.�����1J r.c ���CONSUL7ANT5, lNC, f3031 973-960� 0638 WR..T OT�'�.w� AvCNUE �%1 50-2 F'AX 973-Q847 L�rr�croN, COLORADO DO1 �O RECQRD TO: Nedbo Construction D:47'E: 6123/Z008 PROJECT: Kennedy Residence - 2950 Booth Craek Dr. ❑ RF! ❑ MEET!lt�G NO%S ❑ RESPONSE JOB NUMBER: 0606 � CLARIFlCATIDlY/CHANGE Yhe foilowing record is to clarify the new headsr sizes fbr the new windo+xs to be added at the above referenced project. The �4 foot wide window along the south elevation musi have a(3}-1 3/4x11 7/8 LVL header with (2�1 3/4x5 1r2 LVL stud trimmers and (1}-1 314x5 1!2 LVL king stud on each side. The 5 foot wide window along the west elevatian must have a(3)-2x10 header with single 2x6 trimmers and 2x6 king studs each side. SIGNFD: Loren R. Hill, PE �>,• , ••••�_•s C.,�.•�p� R �~ r . : . -o ? 3211Q : ,� . . �,� :. �1ZZJ,� : � F ' �, .�� .�� kA L EN coPY ro: Nedbo file ...r� � A& D Asbestos Testing and Consulting John R. Peterman ?CXXYXX�CXX�?G P.O. Box 1230 Clifton, CO. 81520-1230 Cell 970-270-3689 Home Phone 970-464-5265 INSPECTION REPORT PREPARED FOR: Nedbo Construction P.O. Box 3419 Vail. CO. 81658 970-845-1001 LOCATION: Residence 29�0 Booth Creek Drive Vail, CO. 81657. tZEPORT PREPARED BY: John R. Peterman Tnspector Manager Certi�cate No. 6601 2 . E•d eE0 = T I 90 iz ��(' A& D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting INTRODUCTION: On June 16th, 2006 an inspection/survey was conducted and 3 bulk samples were collected from the: Residence 29�0 Booth Creek Drive Vail, CO. 816�7 The purpose of the inspection/survey was to locate and sample suspected Asbestes containing materials �ha� might be present in the area of the Residence that is planned for renovation. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.R.A. and State of Colorado Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the e�isting building structures durin� the inspection so there is no documentation for unseen conditions or stored items. All samp�es were analyzed by DCM Science Lab in Wreatrid�e, CQ. Tnis Iaboratory is deemed "Proficien�" in the E.P.A.Quality Assurance (QA) program ror the determ.ination of asbestos in bulk maferials, and is accredited by the American Hygiene Association (AHA). SAlV�PLII�TG PROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered. If during any future demoiition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. 3 �•d et�0 = T T 90 TZ ��C 0 A& D Asbestos Testing and Consuliing John R. Peterman Asbestos7'esting, Project Design, and Consulting Residence 2950 Booth Creek Drive �ail, CO. 81657 �2.E?VOVATION AREA DESCRTPTI011T: The Residence at 2950 Booth Creek Dnve is planned for selective renovation. The interior wa1ls are covered in sheetrock with a Iight te�ture. The c�ilin�s are co�ered wi�i Sile�tiOCk like the wails. i�i`�e iloars are, covered with carpet, ceramic tiles, and hard wood flooring. The heating is provided by hot water heat, electric baseboard heatin�, in-floor heating, and fireplaces. No suspect materials were visible on the heatin� system. C�JNCLliSZONS & RECOMI'vIENDATI4NS: Laboratory analysis, of the bulk samples, indicates that no Asbestos was detected in any of the bulk samples collected. 4 S•d e�0 = I T 90 TZ ��C a 9 -d . � r.� n� N cn �j r p c� ca cD D O II� 0 0 0 � ''� c� �-* � � � v � � cD tr� m a� m '"d p � � � Z C �r .. � O O O � ^� � �� .1 t.� N —` 17l �J C31 � � i� � N � � O � � o° � �'3 O rn ��.� m ~ � � � � D O �, �,� � � z � c-� n y' � `n � y y = '� � :� �: �' m � � � � m �. __ � .. � � o � C ��v, m � cp � v _ � a � � o � a� � � o � � � � � � � � 0 0 � � � � � n � � � � f!� iJ� M ,� fD• tL CD• "j CI! (!7 U3 � �� �' Z <D rn �o c� m c� � 4 � 0 0 0 o c� � 7� 7� 7C' � � � � � � r r r -� � -� rn c� m X it X C C = � -t -t c9 cD CD � �]] Z Z Z D 000 �p r m et�0 = T T 90 TZ unr '�,.�� � -d � � � � N � r � ;< o00 � � � ^' , � � -� �„�, � c? as o� m � m � o' � r � � z z �7 •• � D C N � p o 0 0 � /� � j Z � � o ITi � O � O 77 � D � � o° o � c ,-a o � y :i� � O �• n y -t Q � � n C� C� D � � � � � � � N 'CJ ."S 'C Ci -� C. O O O �7 C' V! N Vl 'ii :'� r: <D fD tD "'� � cn cn cn � G ��� Z a� ��c� — m m c� — .+ .-. � c°� c°� °o O � � � • � � � � � � � � ��� � -� -� -� � c� rn � � x x x � C C -t -. � (D tD cD D � zzz m DDD C1� C7 O � -� O cn -� � -a m 0 0 0 0 0 0 0 0 0 0 eb0=ii 90 Tz ��C 8•d � C � �ii � � � � ca � m �c � � � D 0 0 0 � , � . � � m � m z C C�.) N � � j m � -i � � � � � ccc m ��� o � � � � � m n � � � m � D r O y� c� y < m O O o � ovn � r c� 0 z 0 _� 0 z 0 � � 000 � rn Q 0 0 0 0 0 0 � 0 0 0 -i � Z Z Z � D` D D � � O D � D L� rn C!] C � 'L C�7 C'� y � y C7 N � � r � 0 z d � � � O � � 0 O � n -+ m � O L � � .. � N � � j O �� N � °o o � 0 � n � � � 0 � < m < n� n O � � � � � eS0 = T T..-90--T-�..-un� �. " . 6-d N N tv Cn � � � � 0 0 0 � ,,, mm�a � z � 0 0 0 � W N � a � � D � c� -G -G -< cD n cn ir1 Cn � y o � � � ___ � ° ��� � ___ ��,. � 7 r r- r a' = O O O m � ��� o•� � � y. � � o ODCOC � CD � C G N �• O — � r .� o Z ZZ y c�i O O O � m o a � -9 � � c � � O � � n .. y � � `'� o � y �� r-, � � c,Np 1 � , �., rn � o O °° O 0 N 0 � d � � a � C � � � � <� z �° � < h � � 0 � ..i � v�i � eS0 = T T 90 .T Z �nC J>�n 20 06 00:51a DGM Sci�nc� Lab OT'd � � � � �..,, 3II34638267 zNv((�� z = y n1 '^� � � N � m � N �z Y „ F �_ f % T, � z �' ti ,,, � � � � � v n `y �. Y � °— y o J � �'° � m T � y � b a � rn '1 m O b Q o � � z o � � v � ,T. N O ln q m � C � ? (A P P � P P P � C1 n � m a p n m> oc�ra> o n�+> � A f `3 � � �e "� � � ; � S �. � .-zis ?ciy .��aa � 'n � n: T -1 � p � � v O C � > � � � j Z �A� p az � „rp,� p `�� �� � �;n7: fvC+<� y"� ,s � � � � ;- r � , �.. r � o � C ;' u p � e I � `t] 4 � r.. 7 n m �O I � - b V. a N O� rl N N r^.� N �� J e'� r 3$� \ 0 3° : e � o.s� m Y -� m -a � O � � z � rn z�zz zzz ° zz�=z � ots �DCQ C �7 :7 � ? A I ! � ��� x�t �I o � �� C� � I � n O 0 = �� �� �m � 0 ,�000 ,�000 �aoo .�� C O O O C G�� �7 G � C o ( ��! i: O Z y O yz -� � c�n � w O o O � o �` � � o o O �-i C O O O O O O O.J o G o O ��h N � 7 � � � � Z � I '--7 � °o g�co B��S o��8 1 tnppr o�� o o e � o 0 o b m P.c � r � -, ��y Y � � CW_ ln P `� 9 - > O a � n�� °'� _ ° � � i� m P yi �.. C � n c Z r � z A � rn [p�. � S ..{ {�+ C y � D h � "i � � � � ? n .1 f/i Li Y Z � C � r `� � Z � > �'^ � � � y "o Z�� ^" ''`� '-f 3.�.... m-^ � t'�'" R� -1 O D � � i'i � I �.�-y �✓,i .. � � r� p Z .A��D7 N �� �+Z � ° °z.>.{c�° "'� ;m� � f� Ic1 O�•' "a ti c C A l_+ -a � ''^ ° Y � O P y . `-i v pX. '%.j m m tn ^' � J O � ' N y P P P � ; � t/ �O O 'V m o b o � p � P C` P v � 'L � � C': y m n m m v .':f < D a eSO=TT 80 TZ u�C c 0 _ _�,��,��.,�J1J r.c �� � CON6UL7AN75, iNC, (303! 973-48 �638 WG�r DTrnwia AvfivuE #1 50-2 O� FAX 973-9B47 I.�TTLCTDN, C06i7RAD❑ DO 1 .^.❑ ro: D.4 7'E: Nedbo Construction 6/2 312 0 08 REGQRD PROJECT.� Kennedy Residence - 2950 Booth Creek Dr. ❑ RFl ❑ /l9EET!!dG lVOiES ❑ RESPONSE JOB NUMBER: 0606 � CLQRIFlCaTlON/CNANGE The following r�cord is to clarify the new header sizes for the new windows to be added af the above referenced project. The �4 fovt wide window along the south elevation must ha�e a(3}-1 3/4x11 7B LVL header with (2}-1 3/4x5 1/2 LVL stud trimmers and {1}-1 3/4x5 9!2 LVL king stud on each sic�e. The 5 f�ot wide window along the west elsvation m -2x��(��� 2xE trimmers and 2x6 king studs each side. �' Communit�r Development Department �j� �� V� • Building Safety and Inspection Services Sg�tion ..�`'� �o� ^ tnternational Building Codellntemational �iesidential Cod� uta�ity of permit The issuance or granting of a perm�t shall not be constru�d to be a permit for, or an approvat of, any violation of any of tiis provisions of this code or of any other ordinance of the jurisdiction. Permits pr2suming to give authority to violate or cancel the provision� of this code or other ordinances of the jurisdiction shall n�t be valic�. The issuan�e of a perrnit based on construction docum�nts and other data �~Gll not prevent the building official from requiring ti�� cc�rec';�� cf crrors in the construction documents and oth�r data. The b;<'.' u ,-;iwl is alsa authorized to prevent occupancy cr uso of a �. � i-� v'salaticn of this code or of any other ordinances of Q�o�a�a ��� _ .:.:�;-,. G,.�Q� ►�y,t�r � :�i1NtR: � DATE:�� ! �':� ,_- SIGNED: , o ; �Z110 : C O: ,.-�— -� . � �" ' , �jzzl.� � . ��F•'• •_''.���c'� Nedbo �h"'df��-- �41�j2.� \a Loren R. Hill, PE 9�1'ti"`' �.,,� t�i.t��,✓ � file � �GnwK o�. �,qr,r,t�lr�- \\ -- ----�.� Q'�IC� c�'��