Loading...
HomeMy WebLinkAboutM04-0222TOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 ort,r.*r oF coMMUNrr" or*rort*, NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: MO4-0222 Job Address: 660 LIONSHEAD PL VAIL Location.....: 890 S FRONTAGE RD W ParcelNo...: 210107200003 Project No 'Pr,1o(-o>o f, OWNER VAIL WATER & SANITATTON DISTIO/OB/2004 Phone: PO BOX Y AVON co 8L620 License: CONTRACTOR WIEMER'S HEATING & SHEETMETAL0 /08/2004 Phone: 970-328-9315 P.O. BOX 22 EAGLE. CO 81631 License:198-M APPLICANT WTEMER'S HEATING &' SHEETMETAL1/08/2004 Phone: 970-328-9315P.O. BOX 22 EAGLE, CO 81631 License: 198-M Desciption: INSTALL EXHAUST DUCT ON EXIIAUST FANS Valuation: $4,500.00 Fireplace Information: Resu'icted: Y # ofGas Appliances: 0 #ofGas togs: 0 # of Wood Pellet: 0 **,t* * t ** **:3** ** *,t Mechanical--> 5100.00 Restuarant Plan Review-> 50.00 Total Calculated Fees--> $128.00 Plan Check--> S25 - 00 DRB Fee------------> 50.00 Additional Fees------> 50.00 Investigation-> 50.00 TOTAL FEES---------> 5128.00 Total Permit Fee-----> 5128.00 Will Call--*> S3. O0 Pa],rnent5------------> 5128 - o0 BALANCE DUE-----> SO. OO Item: 05100 BUILDING DEPARTMEI.IT L0/08/2004 JS Action: AP PER CONSUI-,TATION WITH JR Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: l-2 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BI-,DG.): COMBUSTION AIR IS REQUIRED PER SEC. 701 OF THE 1997 UMC, OR SECTION 701 0F rHE 1997 rMC. Cond: 23 (BLDG. ) : INSTALLATION MUST CONFORM TO MANUFACTURES INSTRUCTIONS AND TO CHAPTER 10 OF THE 1997 TJMC, CIAPTER 10 OF THE T997 AMC. Cond:25 (BI-,DG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CIIAPTER 8 AND SHALL TERMINATE As SPECIFIED IN SEC.BO6 oF THE 1997 uMC, OR CHAPTER 8 OF THE 1997 IMC. Cond:29(BLDG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CHAPTER 3 AND SEC.1017 OF THE 1997 UMC AND CHAPTER 3 OF THE 1997 IMC. Cond:31 Bt4 -ot43 Status...: ISSUED Applied. . : 10/08/2004 lssued. .: 10/ll/2004 Expires . ,: 04/09/2005 (BLDG. ) :' BoTLERS sHALL sr Motno oN FLooRS oF NoNcoMBUsrrt coNsr. uNLEss LISTED FOR MOUNTING ON COMBUSTIBI.,E FLOORING. Cond:32 (BLDG. ) : PERMIT, PLANS AND CODE ANAI-,YSIS MUST BE TO AN INSPECTION REQUEST. Cond:30 (BLDG. ) : DRAINAGE OF MECiIANICAL ROOMS CONTAINING BOIL,ERS SHAI_,L BE EQUTPPED WITH A FITOOR DRAIN pER sEcrroN 1004.6 0F THE 1997 rMC. ttali *,1,1tt rl:l * **t *atl t**t't **'**t*a* *r,.t trt,*:trt*t**t *tat,****+t *a*lt*tl DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and zubdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOT'RS IN ADV BY TELEpHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. GNATIJRE OWNER OR CONTRACTORFORHIMSELF AND OWNER POSTED IN MECHANICAL ROOM PRIOR HEATING OR HOT-WATER SUPPLY SEC. LO22 OF THE 1997 IJMC, OR lfl*f+++*t*****+*+*a*aa*a'*{r*taaaa++{ra***l****ttlatt*****'}r}**a*'}+'}**aa*****l*******a*{r*+a*'}'},} TOWNOFVAIL. COLORADO Statement +***+****+t**1*{'{"t+{'lt+lt****ltflaara'tlr{'lr{r***+*{'****t*'***'+a**a***'}+a**l************:}++'}*:tt+t*** Statenent Number: R040006879 Amount: SL28.00 ]-0/tL/200402:38 PM Payment Method: Check Inits: DDGNotation: Wiemers 4 815 Permit No: Parcel No:Site Address : IJocation : This Payment: M04-0222 l!'pe: MECHAIiIICAIJ PERMIT 21010?2 00003 650 I,IONSHEJAD PL VATL 890 S FRONIAGE F,D W Total Fees : MECHN{IICAI, PERMIT FEES PLNiI CHECK FEES WILI, CAI.,L ]NSPECTTON FEE s128.00 Total ALL Pnts : s128.00 s128.00Balance: S0.00*r***'r*,****ttif**{'****a!'}!t'}{'****it**tffttttttt*+tt*tttt***ttfft***tt***********ttt*t*'}'t|t't*'}**** ACCOUNT ITEM LIST: Account Code Descript ion Current Prnts MP PF WC 001000031r.1100 00100003112300 0010000311_2800 r.00.00 25.00 3.00 APPTICATION vill no, BE AcCEPTED IF INCoMPLE,,Q un,, Project #: Building Permit #: Mechanical Permit #: 97 O-47 9-2149 (Inspections) Provide Mechanical Room Layout drawn to scale to tnto#fltr'wad CONTRACTOR INFORMATION -ZS-Z MVNOFUAIL 75 S. Frontage Rd. Vail, Colorado 8f657 Permit will not be accepted without the following: ECEIV ii(li {l 8 -,i.1 TOV-COM.DEV. Mecha nical Contractor :Town of Vail Reg. No.: E-Mail Address: MECHANICAL: Sj46O Or oo COMPLETE VALUATION FOR MECHANICAL PERMIT Labor & Materials ^/. a9\*****[**K***********x***FOR OFFICE USE ONLy*****************************I ocT -','2004g..l 2JF Conbct Assessrc Otrice at 970-328-8640 or visit for Parcel # Parcel# .l_tO3 \^\O JobMdressToo s, F?-.,y',.., z D, ilAt/ Engineer: -=lrAr",tuo/ A eY/-a,-;'fp,us WorkClass: New.,1if Addition( ) Alteration( ) Repair( ) Other( ) Does an EHU e><ist at this location: Yes ( ) No ( )Boil€rLocation: Interior( ) Exterior( ) Other( ) Type of Bldg: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: : Gas Aopliances ( ) Gas Noffype of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to En EPA Phase II device? Yes ( ) No \Wail\dataMev\FoRMS\PERMITS\I\4ECHPERM.DOC L"e 01D6nW2 Aug-30-2004 l7:27 F'*+'Tx,'SOJ:,1J Goldcn, Colondo 8040t Tcl: (303) 239-5400 Eax: (fr3\ 219-5451 www.brownandcaldrrcll,com t-4?t P.001/001 F-6i53032395454 August 30,2C{J4 N11. (htis FeAti-a . Site Resource Management 0189 Sawatch Road Eagle, CO 81631 Re Vault Wall Modifications for Louver Openings Chris, It was brought to our attencion that the three louver openings will leave otrly about two inches of cooctete between of rhe tops of the openings and the bearing elevation of the double tees. we tecomrneod that the ttnro exhaust louvers n€:u the ends of the south wall be lowered by 2'-0" +/-, The resulting o*ro-foot deep beam should be reinforced with two additioaallor$rudinal #5 bars above the opening and #4 dosed stirnrps at 10,, oo. ceoter. The ceotet, inrke louver should be lowered by l'-C' +/- and the opening should be centered directly between two double tee leg bea'ing pockets. This one-foot deep beam should be reinforced with fovt additional #5 tongitudinal bars above the oper''i.g; two top and two bottom. No stirrups are required if the opening is dead center between the double tee beadng pockets as described above. Please contact us if thete are an)r questions rcgarding this issue. Sincerely, BROWNAND CALDIVELL -A#U/,l/'- ScottW. Harper, P.E. Supervising S auctural Engineer Cc: Dave Myers - Brown and Caldwell OWwe- CgPV '/ E n gi t c c r r Coasultanrt ,ffffi b*d Environmcntal Bo4-c43 3032395454 T-420 P.00?/006 t-668Auc-25-?004 l0:35 Fron-Brown and Joll 1697 C.olc Boolonlrt Gold.o, C.oloedo 80401 T& (303) 23!5{oo Fut (30t) 39-5'154 .nrrw.brou'naldeldwclkom Chris, The projecds Ptccast suPPbcr, Plun Geek Suucnre$' prefers to use Precasl dorrble rces for the vauh roof .**Jloltft of pr.."rt_sl^bs as slowo on our drawings' The double tec alternadve t 'f'o*o on Uc ptt'- Crcek shop drawings &rcd " August 13,2004. W. g"oto":tJa tftc foru atrachcd d'et"ils to show de wdl modificatiohs that qrill be oeccssary to accommodate dre double tees' Please aote that Phur Creck Suuctures is responsible for tbc reinfotcement in the fow- inch deck toPPiog otu, Ot aooUft itt'' W" *"un }ike to see a shop driwiog of rhe topping rciafotcedreot ,o .f,tt *t cen t€niew it for coofotmance wirh our original vault design' Pleasc cooact us if there trc aoy quesuons regardi.ag dris issue' Tha'ok you' Sincerely, BROWN AND CALD\fETI.jaflril*^' Scott !f. HarPer, P'E- Supewisrog Suucn:re Engi'oeer August 25,20Q4 Mr. Chds Fedrizzi Sitc Resource Management 0189 Sawatch Road Eaglc, CO 81631 Re: Vauh Modifications for Ptecest Double Tccs P:\D GENvail Rcsons\Conc+o0'dcncs\Yaulr Roo( Modificstioo lJncr 8-2A'04'doc' .. I E.- - ' . .., t 6 Corstlraatt Fron-Brorn anU Jall !-e D ro" (t,.u) d.A,S' {x2. o Re'r. Dar*t> _ 4/214. 4r'toAvt*Ut n4 :/e'lU Toff,,t4 E€tP ey efue4+ 4 5 aour C 7".vn1i ?e€/-,^47uaUbLP T4' @e b1 4fV-Dqu'e.w b4x Iv 6 x7 x e/gx e'- uy' fz) a/onPxot'a u aeF)tc' e ft"o-e^ ualj ur A? 4 ()bw 2ei7 (rl*e,J C- b^' 7oa*el) €L. 1:2.w1. -- fuqo.t1 slvlo4252t4 k^,M4Xav*Wr :/to> 4. E s€Tds-I fadx-fs ,', Ln *5* la,;= ua? 'l ila* VA lacFl Petxl6, *22 C(uwE- eAE- Q rc-'t 6t'c- ' * J^r' 4 a1? *Q ty'Au-' ?a$T,*6 x er:'y C e,4' (aaue7. (fire,.t qd' eA' f-'xql From-8rown anO Jell ?vDA E'/ dttJE+ z-lPIa4 J DaNv t/4tq44^taS,'t>YtM UATV zL04 /tALL €AOe t*5x I e tz'a'a' 6p V d'^v- P'e bt ft-Jtt @€Y, 4IeruTdA€9 TafPtPTt 4trr,JF. ts-l arH€Re e6 ,-orf aA. FA.E "A%p fr- b\ aW,F +lepf 4& ++4-( a Farz L-^1oJT e 6 +)d'#s-e n-,'o/-, u., L^P 4 TYP,"b r^)l,ll-. R.-oNl, EL, TO,d, - 921Q, 11 From-Brown and ]ell sltalo4 o/+'to24rta*AlV 4oo zaN4'eq 4'lo4 (aA heo'v U)Avt- rrJf,a' *oQLz't',t' ulauL)hnwt C 4etft) Sep-09-2004 |l:10 ""-"'ailJi#ry:': Gold.o, Coiorado 80401 Td: 603) 239-5400 Fu 0$) 299-5454 w.nw, brownsndca[dwcll. com 3032395454 T-436 P.001/001 F-685 September 9,2004 lyft. Qhris Fed;-ti Site Resoruce Malagement 0189 Sawatch Road Eagle, CO 81631 Rq Topping Reinforcement for Vault Ptecast Double Tees Cbds, The project's precast supplier, Plum Creek Strucnues, prefers to use Precast double tees for the vault roof structure iastead ofprecast dabs as shown on the Brown and Caldwell design drawings. lbe double tee dternative is shown oa the Plum Creek shop drawings dated August 13,2004. This change is acceptable to Brown and Caldwell. Please note t}at Plum Creek Structures is responsible for t}le reioforcement irr the four- inch deck topping over the,double tees. Their eagineer, Howard Knapp, has scaled the calculations. Please consider the amched Plum Creek drawing as the contrect drawtng for the placement of the topping reinfotcernent. Plcase coatact us if there are any questions regarding this issue. Sincereln BROWNAND CAIDWELL -/rtilrilrl^- Scon W. Harper, P.E. Supervisiog Strucrure Engiacer "ffiffii- 2t074 5i' koo# Enaironmental Enginecrt Co n t u lra n rs