Loading...
HomeMy WebLinkAboutADM040003~~tt ~~ Manning ~dministra~ive Action F~~~n Department of Community Development 75 South Frontage Road, Vail, Cotorado 81657 tel; 970.479,2139 fax; 970.479,2452 web: www.vailgov.com Project Name: BASINGDALE 5 APPEAL ADM Number: ADMfl4flfl03 Project Description: AN APPEAL TO CL?UNQL QF A DRB FINAL REVIEW DENIAL Participants: QWNER W. L BROER CONST CO 11528 S. WARPAINT PHEONDC AZ 85044 license: APPLICANT PETER CAPE Pfl BOX 1832 VAIL CO 81658 License: Q5 jig j7n04 Phone: 480-893-9688 05!28!2004 Phone;970-479-0795 Project A~~ress: 2830 BA.sINGDALE BLVD MAIL 2$3fl BASINCDALE BLVD. L,ocatiun: Legal t~escription: Lot: 5 Mock: 9 S:ibdivision: °JAIL INl"ER~"~iOI;NTAiN DEV S Parcel Nutatber: 21fl314301fl30 iomrr-e~ts: DRB denial overturned-see conditions BOARDJSTAFF AG'T3t~N Action: APPRQVED Date of Approvat: 06!15!2004 Conditions: Cond: 8 (PLAN}: No changes to these plans may be made without the written consent. pf Town of Val! staff andjor the appropriate revi2w commstkee~(s}, Cond: CONflOp6515 The trees in question are to b~ replaced by the applicant in conjunction with a revised landscape plan, concurrently e with building permit subrni~al, depicting adequate replacement cif the trees being removed. Pta~ne~: Matt t~ennett AiiM Fee laid: ~1UOA0 ~~•,,. ~ ,r ,..-~ -. Department of Community De ve%pment Building Safety and Inspection Services 75 South Frontage Road fail, Co%rado 81657 970-479-2138 FAX 970-479-2452 www, vailgov. com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor/Applicant Architect Van Diemen Inc. none Peter Cope proj# FAX/Email #: p-kcope@comcast.net NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: 3 Chris Gunion, Building Plans Examiner 06/01/2005 B05-0087 WL Broer Const. Co. 2830 Basingdale R-3/U V-B 3+basement The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code and 2002 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit: For processing: • Please submit two complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment by marking the attached list or creating a response letter. Indicate which plan sheet, detail, specification, or calculation shows the requested information. Please send revisions to the attention of the plans examiner with the building permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature, registration number and date on the cover page of any structural calculations, all structural details and structural sheets of the plans. For commercial or multi-famil r~projects all sheets of the plans must be stamped. Plan approval from Town of Vail Planning, Public Works and VFES is required prior to issuance of a building permit. Architectural Comments: 1 Amend lower level floor plan to show an accurate proposed floor plan and use of spaces labeled as crawl space. Please refer to structural plans. These are not crawl spaces. Provide windows for natural light and ventilation for these spaces. (R303) 2 Amend site plan and floor plans to show location of the proposed lot split property line. 3 Provide party wall detail. Common walls adjacent to property line shall consist of (2) 1 hour wall assemblies with a minimum 1" airspace at the property line. Per the IRC section R302, "Location on Lot" provisions. Provide a UL or gypsum association listing for the 1 hour wall assemblies. The wall assembly shall also have a minimum STC rating of 50. 4 Exterior walls of R-3/U-1 occupancies are required to be one hour fire resistive construction where located less than 3' from property line. Revise plans. Provide a UL or gypsum association listing for the 1 hour wall assembly. Revise plans to show 1 hour construction at the overhangs within 3' of duplex property line. (R302) 5 Openings are not permitted in exterior walls of R-3/U-1 occupancies are not permitted less than 3' from property line. Revise plans and mechanical chimney and upper level bathroom window (R302) 6 Amend plans to specify 1 hour occupancy separation between garage and dwelling unit (R309.2) -Garages beneath habitable rooms shall be separated from all habitable rooms by not less than 5/8" type X gypsum board 7 Specify a 1 3/8" solid wood door or a rated 20 minute door between garage and dwelling. (R309) 8 Clearly indicate on the plans type and size of windows to be installed ex; casement, horizontal sliding, single hung. If window schedule is used, provide window numbering or other method to identify windows. (R303) 9 Amend plans to provide at least one operable window or door approved for emergency escape for each sleeping room or basement. (R310.1) Opening must comply with all of the following: -Maximum finished sill height of not more than 44" above the floor -Shall have a minimum net clear opening area of 5.7 square feet -The minimum net clear opening height dimension shall be 24" -The minimum net clear opening width dimension shall be 20" 10 Amend stairway design to comply with the following: (R311.5) -minimum width of stairways shall not be less than 36" -maximum riser height 7 3/a" -minimum tread depth of 10" -minimum headroom clearance of 6"-8" -handrail on at least one side of stairway 34"-38" above nosing of treads -handrail ends to be returned to wall or terminate in newel posts -handgrip portion of handrails shall be 1 1/4"-2" in cross sectional dimension -handrails to be continuous between landings (can be interrupted by a newel post at a turn) -stairway shall not rise more than 12' vertically between landings -for circular, spiral and winding stairs detail requirements in R311.5.8 and IBC1009 Structural Comments: 11 Provide (2) sets of structural plans stamped and signed by the engineer of record. Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. Chris Gunion I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2369 cgunion@vailgov.com F:\cdev\CH RIS\PERMIT.COMMENTS\B05-0087. DOC