Loading...
HomeMy WebLinkAboutB03-0313 EXPIRED.pdfTOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 3 d ADD/ ALT COMM BUILD PERMT Permit #: B03 -0313 Job Address: 2211 N FRONTAGE RD VAIL Status ...: ISSUED Location.......: 2211 N FRONTAGE RD Applied..: 10/09/2003 Parcel No....: 210311415017 Issued ...: 11/20/2003 Project No. - d - p 3 3 Expires ...: 05/18/2004 OWNER DEBIR2 HOLDINGS LLC 10/09/2003 Phone: C/O VICTOR A. VILAPLANA 750 B ST STE 2100 SAN DIEGO CA 92101 License: CONTRACTOR MATSEN ENTERPRISES 10/09/2003 Phone: 970 - 748 -1332 P.O. BOX 7796 AVON, CO 81620 License: 680 -B APPLICANT MATSEN ENTERPRISES 10/09/2003 Phone: 970 - 748 -1332 P.O. BOX 7796 AVON, CO 81620 License: 680 -B Desciption: TENNANT FINISH NEW RESTAURANT "BULLCRABS" Occupancy: A3 A3 Type Construction: V1-HR Type V 1 -Hour Type Occupancy: ?? Valuation: $19,000.00 Add Sq Ft: 0 Fireplace Information: Restricted: of Gas Appliances: 0 of Gas Logs: 0 Wood Pellet: FEE SUMMARY Building ---> 307.25 Restuarant Plan Review–> $75.00 Total Calculated Fees –> 584.96 Plan Check —> 199.71 DRB Fee -> $0.00 Additional Fees- 0.00 Investigation -> 0.0o Recreation Fee – > $0.00 Total Permit Fee- 584.96 Will Call—> 3.00 Clean-up Deposit —> $0.00 Payments 584.96 TOTAL FEES– > $584.96 BALANCE DUE 0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 11/17/2003 GCD Action: AP Item: 05400 PLANNING DEPARTMENT 11/17/2003 Matt Gennett Action: AP Item: 05600 FIRE DEPARTMENT 11/14/2003 mcgee Action: AP of PAGE 2 CONDITIONS OF APPROVAL Permit #: B03 -0313 as of 11 -20 -2003 Status: ISSUED Permit Type: ADD/ ALT COMM BUILD PERMT Applicant: MATSEN ENTERPRISES 970 - 748 -1332 Job Address: 2211 N FRONTAGE RD VAIL Location: 2211 N FRONTAGE RD Parcel No: 210311415017 Description: TENNANT FINISH NEW RESTAURANT "BULLCRABS" Conditions: Cond: 1 FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Applied: 10/09/2003 Issued: 11/20/2003 To Expire: 05/18/2004 Item: 05500 PUBLIC WORKS Item: 05700 ENVIRONMENTAL HEALTH 11/17/2003 BC Action: AP See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed anaccurateplotplan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoningandsubdivisioncodes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 479 -2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. ZI SIGNATWATOF OWNER OR C VTRA,eTVFOR HIMSELF AND OWNEI TOWN OF VAIL, COLORADOCopy Reprinted on 02 -22 -2013 at 15:12:10 02/22/2013 Statement Statement Number: R030005098 Amount: $75.00 11/10/200304:56 PM Payment Method: Check Init: BC Notation: #624 /scott c bucy Permit No: B03 -0313 Type: ADD /ALT COMM BUILD PERMT Parcel No: 2103 - 114- 1501 -7 Site Address: 2211 N FRONTAGE RD VAIL Location: 2211 N FRONTAGE RD Total Fees: $584.96 This Payment: $75.00 Total ALL Pmts: $584.96 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts FS 00100003112400 RESTAURANT PLAN REVIEW 75.00 TOWN OF VAIL, COLORADOCopy Reprinted on 02 -22 -2013 at 15:12:13 02/22/2013 Statement Statement Number: R030005174 Amount: $509.96 11/20/200301:32 PM Payment Method: Check Init: DF Notation: #2595 Permit No: B03 -0313 Type: ADD /ALT COMM BUILD PERMT Parcel No: 2103 - 114 - 1501 -7 Site Address: 2211 N FRONTAGE RD VAIL Location: 2211 N FRONTAGE RD Total Fees: $584.96 This Payment: $509.96 Total ALL Pmts: $584.96 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 307.25 PF 00100003112300 PLAN CHECK FEES 199.71 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 I APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNS f Project #: m03f Building Permit #: T 1 110FYAB, ING PERMIT Sep Pe are q r electrical, piu 75 S. Frontage Rd. Vail, Colorado 81657 r FORMATION VALUATIONS FOR BUILDING PE t Phone Vs: v %49A For Parcel # Contact Office at 970 - 328 -8640 or visit Job Name:[' i`._ kJob Address: N, Legal Description Lot: 1 Block: Filing: dj Subdivision: yy Owners Name: Address:1 (, Phone: V Architect/Designer: _ /__. Address: I t v3,L Phone: g -WI Engineer: Address: Phone: Work Class: New () Addition ( ) Remodel Repair ( ) Demo ( ) Other ( ) Work Type: Interior ) Exterior ( ) Both( ) Does an EHU exist at this location: Yes ( ) No T.,. „f RlAn • Cinnla_f2MHv ( I Two - family f ) Multi- family jiViCommercial ) Restaurant Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: b No/Type of Fire laces Existing: Gas Appliances Gas Los Wood /Pellet Wood Burning No/Type of Fire laces Pffigtas Appliances Gas Los Wood /Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes gg No( ) Does a Fire Sprinkler System Exist: Yes ( ) No TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Job Address: 2211 N FRONTAGE RD VAIL Location.....: 2211 N FRONTAGE RD Parcel No...: 210311415017 Project No S OWNER DEBIR2 HOLDINGS LLC Ai0/28/2003 Investigation —> C/O VICTOR A. VILAPLANA Will Call —> 750 B ST STE 2100 TOTAL FEES —> 363.00 BALANCE DUE--> $0.00 SAN DIEGO CA 92101 Item: 06000 ELECTRICAL License: 11/12/2003 DF Action: AP OK PER GREG TO RELEASE CONTRACTOR BIG BEAR ELECTRIC, INC. 10/28/2003 P. O. BOX 474 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS LEADVILLE, CO 80461 License: 291 -E APPLICANT BIG BEAR ELECTRIC, INC. 10/28/2003 P. O. BOX 474 LEADVILLE, CO 80461 License: 291 -E Permit #: E03 -0226 163 - 63 3 Status ...: ISSUED Applied..: 10/28/2003 Issued. .: 11/14/2003 Expires . .: 05/12/2004 Phone: Phone: 970 - 390 -9221 Phone: 970 - 390 -9221 Desciption: INSTALLING ELECTRICAL WIRING FOR RESTRANT,EQUIPMENT AND LIGHTING Valuation: $20,000.00 FEE SUMMARY Electrical —> 360.00 Total Calculated Fees —> $363.00 DRB Fee — —> 0.00 Additional Fees - -> $0.00 Investigation —> 0.00 Total Permit Fee > $363.00 Will Call —> 3.00 Payments > $363.00 TOTAL FEES —> 363.00 BALANCE DUE--> $0.00 Approvals: Item: 06000 ELECTRICAL DEPARTMENT 11/12/2003 DF Action: AP OK PER GREG TO RELEASE Item: 05600 FIRE DEPARTMENT CONDITIONS OF APPROVAL Cond: 12 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 441 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. y SIGNATURE OF OW14ER OR CONTRAVO -YA'OR HIMSELF AND OWNEI TOWN OF VAIL, COLORADOCopy Reprinted on 02 -22 -2013 at 15:12:30 02/22/2013 Statement Statement Number: R030005131 Amount: $363.00 11/14/200303:12 PM Payment Method: Check Init: DF Notation: #3769 big bear electric Permit No: E03 -0226 Type: ELECTRICAL PERMIT Parcel No: 2103 - 114 - 1501 -7 Site Address: 2211 N FRONTAGE RD VAIL Location: 2211 N FRONTAGE RD Total Fees: $363.00 This Payment: $363.00 Total ALL Pmts: $363.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts EP 00100003111100 TEMPORARY POWER PERMITS 360.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 f COt+IPL.ETL SQ. fa rt Awxw OFD sQ FT I1.,'fit C1 TOWN Amendment to the 1999 N.E.C. Town of Vail Ordinance 10 -1 -6. Overhead services are not allowed in the Town of Vail. Underground services have to be in conduit (PVC) from the transformer to the electric meter, main disconnect switch and to the first electrical distribution circuit breaker panel. The main disconnect switch shall be located next to the meter on the exterior wall of the structure easily accessible. All underground conduits are required to be inspected before back - filling the trench. In multi - family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are accepted. NM Cable (Romex) is not allowed in commercial buildings or structures exceeding three (3) stories. No use of aluminum wire smaller than size #8 will be permitted with the Town of Vail. TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES All installations of exterior hot tubs or spa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if applicable). If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30" above grade, you must also obtain a building permit. If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and verify that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. If this is a remodel in a multi- family building with a homeowners association, a letter of permission from the association is required. If this permit is for a commercial space, two (2) sets of stamped drawings are required. I ve read and understand the above. T5Z7' Signature Date Signed If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970 - 479 -2147. The inspector can be reached on Tuesday, Thursday and Friday mornings between the hours of 8am and 9am. You may also leave a voice mail and the inspector will call you back. TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F03 -0042 Job Address: Status ...: ISSUED Location.....: 2211 N FRONTAGE RD Applied. . 12/12/2003 Parcel No...: 210311415017 Issued . .. 01/22/2004 Project No m3 631? 3 Expires . .: OWNER DEBIR2 HOLDINGS LLC 12/12/2003 Phone: C/O VICTOR A. VILAPLANA 750 B ST STE 2100 SAN DIEGO CA 92101 License: CONTRACTOR ROCKY MOUNTAIN FIRE & SAFETYI2 /12/2003 Phone: 303 - 321 -0345 P.O. BOX 810 COMMERCE CITY 80037 -0810 License: 590 -S APPLICANT ROCKY MOUNTAIN FIRE & SAFETYI2 /12/2003 Phone: 303 - 321 -0345 P.O. BOX 810 COMMERCE CITY 80037 -0810 License: 590 -S Desciption: INSTALL OF PYROCHEM PCL -460 FIRE SUPRESSION SYSTEM Valuation: $2,482.00 FEE SUMMARY ****#***#*******#****#***#*** * # # * * * # * * * * * * * * * # * * * * * * * * # * * * ## Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees - -> $458.49 Plan Check --- > $350.00 DRB Fee----------- - - - - -- > $0.00 Additional Fees -------- - -> $0.00 Investigation -> $0.00 TOTAL FEES------ - - - - -> $458.49 Total Permit Fee ---------- > $458.49 Will Call - - - - -> $3.00 Payments ----- --------- —> $458.49 BALANCE DUE ------ $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 01/14/2004 mvaughan Action: AP CONDITION OF APPROVAL Cond: 12 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY OUR HOURS IN ADVANCE BY TELEPHONE AT 479 -2135 FROM 8:00 AM - 5 PM. / -- TURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADOCopy Reprinted on 01 -22 -2004 at 12:21:11 01/22/2004 Statement Statement Number: R030005296 Amount: $458.49 12/22/200309:39 AM Payment Method: Check Init: LC Notation: #12458 /Rocky Mountain Fire & Safety, inc. Permit No: F03 -0042 Type: SPRINKLER PERMIT Parcel No: 210311415017 Site Address: Location: 2211 N FRONTAGE RD Total Fees: $458.49 This Payment: $458.49 Total ALL Pmts: $458.49 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 SPRINKLER PERMIT FEES 105.49 PF 00100003112300 PLAN CHECK FEES 350.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Project #: Building Permit #: Sprinkler Permit #: 970- 479 -2135 (Inspections) TOWN OF RAIL TOWN OF VAIL FIRE SPRINKLER PERMIT APPLICATION Fire Sprinkler shop drawings are required at time of permit submittal and 75 S. Frontage Rd. must include the following. Permit application will not be accepted Vail, Colorado 8165 without this information: A Colorado Registered Engineer's stamp or N.I.C.E.T. Level III (min) sta mp. Equipment cut sheets of m rial Hydraulic calculations. -- A State of Colorado Plan Registration form. Plans must be submitted by a Registered Fire Protection Contractor. ft CONTRACTOR INFORMATION Fire Sprinkler: $ Z + Z . C Labor & Materials) tact Eagle County Assessors Office at 970 - 328 -8640 or visit www. eagle - county, com for Parcel # Rarcel # Date Received: Public Way Permit Fee: Accepted By: Occupancy Group: Job Address: Legal Description Lot: Block: Filing: Subdivision: Owners Name: Address: Phone: Engineer: Address: Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) jC -elf c l - l 4cq j Detailed description of work: Work Class: New Addition ( ) Remodel ( ) Repair ( ) Retro -fit ( ) Other ( ) Type of Bldg.: Single- family ( ) Two - family ( ) Multi- family ( ) Commercial ( ) Restaurant Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Does a Fire Alarm Exist: Yes( ) No( ) Does a Fire Sprinkler System Exist: Yes( ) No ( ) Y.XXY.Y.Y.Y.Y.Y:XYY:C:Y XYYXi:XYYYYY XYYXYY CY ::YYY FOR OFFICE USE ONLYYYY] FY]: T *Y)CXYYYXYYYTY>CYXYYY)MX]CYX]C Y:X Other Fees: Date Received: Public Way Permit Fee: Accepted By: Occupancy Group: Vail\ data \cdev \FORMS \PERMITS \SPRKPERM.DOC 07/26/2002 READ PL STA PYRO CHEM PCL- 460 SYSTEM TOTAL FLOW POINTS 15 MAX COVERAGE NOZZLE FLOW POINTS NOZZLE PLACEMENT DUCT 2D 2 AT INTERFACE PLENUM 2 -1 H 2 EVERY 10 FT. GRIDDLE 1H 1 24 - 48 INCHES RANGE 2L 2 34 - 48 INCHES RANGE 1H 1 40 - 50 INCHES CHARBROILER 2H 2 36 - 48 INCHES FRYER 2H 2 24 - 48 INCHES TOTAL FLOW POINTS 12 1 IIS SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH NFPA 17A6 UL 300 STANDARDS, AND ALL MANUFACTURE SPECIFICATIONS BULL CRAB REST. 2211 WEST VAIL RD. VAIL, CO. 81657 INSTALLATION INSTALLER(S) FIFE: 310" BLACK SCHEDULE 40 wr, EMT CONDUIT - CORNER PULLEY EACH CHANGE OF DIRECTION REMOTE PULL STATION LOCATED IN THE PATH OF EXIT GAS VALVE TO SHUT DOWN OAS SUPPLY UPON ACTIVATION MICRO SWITCH SUPPLIED TO CONTRO 4LL ELECTRICAL FUNCTIONS EXHAUST FAN MUST STAY ON OR COME ONIF OFF x MAKE UP AIR MUST SHUT DOWN ALL ELECTRICAL APPLIANCES AND OUTLETS UNDER THE HOOD MUST SHUTDOWN INTERCONNECT FIRE ALARM PANEL IF EXISTING 121812003 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M03 -0231 s63-03c3 Job Address: Status ...: ISSUED Location.....: 2211 N FRONTAGE RD Applied..: 10/29/2003 Parcel No...: 210311415017 Issued . .: 11/25/2003 Project No 'k>R-5 (j yo 3`( 3 Expires . .: 05/23/2004 OWNER DEBIR2 HOLDINGS LLC C/O VICTOR A. VILAPLANA 750 B ST STE 2100 SAN DIEGO CA 92101 License: CONTRACTOR R & H MECHANICAL LLC 1047 CHERRYVALE ROAD BOULDER, CO 80303 License: 184 -M APPLICANT R & H MECHANICAL LLC 1047 CHERRYVALE ROAD BOULDER, CO 80303 License: 184 -M Desciption: rest. ventialation system Valuation: $45,500.00 10/29/2003 Phone: 10/29/2003 Phone: 303 - 543 -9894 10/29/2003 Phone: 303 - 543 -9894 Fireplace Information: Restricted: Y # ofGas Appliances: 0 # ofGas Logs: 0 # of Wood Pellet: 0ssss**#*##* s*##*#* s* s##* s* s** s*#*# s # *s * * * *s *s * # * * *s *s * # * * * * # *s * * ** FEE SUMMARY s*###*#*** s*###**## sss*##*### s *s *s# * * * # * * # * # * * * * * * * * * * * * # # ** Mechanical - -> 920.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees - -> 1,153.00 Plan Check --- > 230.00 DRB Fee ---- --------- - -> $0.00 Additional Fees ------- - -> 0.00 Investigation -> 0.00 TOTAL FEES---- - - - - -> $1,153.00 Total Permit Fee ------- - -> 1,153.00 Will Cal 1 - - -> 3.00 Payments----------- - - - - -> 1,153.00 BALANCE DUE- - - - - -> 0.00 Item: 05100 BUILDING DEPARTMENT 11/17/2003 GCD Action: AP Item: 05600 FIRE DEPARTMENT 11/14/2003 mcgee Action: AP CONDITION OF APPROVAL Cond: 12 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 BLDG.): COMBUSTION AIR IS REQUIRED PER SEC. 701 OF THE 1997 UMC, OR SECTION 701 OF THE 1997 IMC. Cond: 23 BLDG.): INSTALLATION MUST CONFORM TO MANUFACTURES INSTRUCTIONS AND TO CHAPTER 10 OF THE 1997 UMC, CHAPTER 10 OF THE 1997 IMC. Cond: 25 BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 8 AND SHALL TERMINATE AS SPECIFIED IN SEC.806 OF THE 1997 UMC, OR CHAPTER 8 OF THE 1997 IMC. Cond: 29 BLDG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CHAPTER 3 AND SEC.1017 OF THE 1997 UMC AND CHAPTER 3 OF THE 1997 IMC. Cond: 31 BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 BLDG.): DRAINAGE OF MECHANICAL ROOMS CONTAINING HEATING OR HOT -WATER SUPPLY BOILERS SHALL BE EQUIPPED WITH A FLOOR DRAIN PER SEC. 1022 OF THE 1997 UMC, OR SECTION 1004.6 OF THE 1997 IMC. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the TownAplicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADV LEP ONE AT/479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. SIGNATU Op'OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADOCopy Reprinted on 02 -22 -2013 at 15:13:03 02/22/2013 Statement Statement Number: R030005201 Amount: $1,153.00 11/25/200310:23 AM Payment Method: Check Init: JRM Notation: #13420 Permit No: M03 -0231 Type: MECHANICAL PERMIT Parcel No: 2103 -114- 1501 -7 Site Address: Location: 2211 N FRONTAGE RD Total Fees: $1,153.00 This Payment: $1,153.00 Total ALL Pmts: $1,153.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts MP 00100003111100 MECHANICAL PERMIT FEES 920.00 PF 00100003112300 PLAN CHECK FEES 230.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 10/23/2003 10:05 9703280234 75 S. Frontage Vail, Colorado, ol R H MECHANICAL PAGE 01 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNProject #: Building Permit #: Mechanical Permit #: 970 -479 -2149 (Inspections) TOWN OF VATL MECHANICAL PERMIT APPLICATION MECHANICAL: $ q S- 6 O 0 Pi Permit will not be accepted without the following: . P Dur ae wi. iw _r_ri ...wlesni info /Y]/f7 EJlfr i%A1'/ ContACtE le Coan As5es501's urnce arAv-•v vi ir.r .•• ••••••• •- -- -- - Parcel J# p - y,rsr' Job Name: Jo Address: 3t.11 Cno.b fo td Legal Description Lot: [Block: Filing: Subdivision: Owners Name: Address: i I F - ' Phone: )o-396-5r11-7. Engineer: REC Address: i, ma Phone: ? i e Detailed description of work: Kest Work Class: New () Addition ( ) Alteration Repair ( ) Other( ) Boller Location: Interior ( ) Exterior ( ) Other ( ) Does an EHU exist at this location: Yes ( No Type of Bldg: Single - family ( ) Duplex ( ) Multifamily ( ) Commercial ( ) Restaurant Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No a of Fire laces Existing: Gas A liances Gas s Wood Pellet Wood Burning No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood /Pellet ( ) ' 0 ED) Is this a conversion from a wood buming fireplace to an EPA Phase II device? Yes ( ) o vai1\daiabdev\F0RM5\PERMrrSWECHPERM.DOC k wylum n I r Architectural Engineering Consultants Mechanical & Electrical Design Services December 24, 2003 Mr. Greg Denckla Town of Vail Building Department 75 South Frontage Road Vail, CO 80443 Re: Bull Cra ! estaura uctwork Sizing Permit M03 0231 Dear Greg, Per your request the following addresses the field modified supply, return and bar exhaust ductwork sizing on the above referenced project. R & H Mechanical installed 18X15 supply and return ductwork from RTU -1 in lieu of the 30X10 indicated on our engineering documents. Although the calculated free area of the installed ductwork is less than the specified the static pressure and velocity variances between these two difference duct sizes is negligible and will not have any adverse effects on the total supply air delivered into the space. The balance reports prepared by an independent test & balance contractor at the end of the project will establish that the specified air is being delivered into dining room and kitchen. In reference to the bar exhaust, again field conditions that we were not able to verify during the design stage require R & H Mechanical to field modify the exhaust ductwork. Again the free area of field installed exhaust ductwork is less than that specified on our engineering documents. Since exhaust of the bar area is not required by the mechanical code and was designed as a comfort system we do not take any exceptions to the slightly reduced exhaust capacity that will achieved with the reduced exhaust duct sizes. Should you require any additional information please feel free to contact me at your earliest convenience. Sincerely, Architectural Engineering Consultants Robert P. Cummings President / Owner 40801 US Hwy 6 & 24, Suite #206, Eagle -Vail, Colorado 81620 Post Office Box 8489, Avon, CO 81620 Phone: 970 - 748 -8520 Facsimile: 970- 748.8521 Email: stan@aec- vail.com http: / /www.aec- vail.com TOWN OF VAILY Department ofCommunity Development 75 South Frontage Road Vail, Colorado 81657 970 - 479 -2138 FAX 970 - 479 -2452 www.ci.vail.co.us March 16, 2004 Mr. Robert Cummings Architectural Engineering Consultants P.O. Box 8489 Avon, CO 81620 Re: Letter of February 26, 2004 Bull Crab Restaurant Dear Bob, Regarding your letter requesting a `variance' eliminating the requirement for the type II hood over the dishwasher. The building department rarely approves variances. However the 1997 Uniform Mechanical Code section 105 does allow us to consider alternate methods and materials, `if it can be demonstrated that the proposed design is satisfactory and that the equivalent of that prescribed in the code has been met'. As such the system designed for the kitchen in Bull Crab Restaurant is approved per this section. The exhaust and makeup air provided is adequate as demonstrated by the balance report dated January 30, and your letter of February 18, 2004. Very TrulyP;eA- Y' Greg D ckla Building Inspector/Plans Examiner Town of Vail 1WOR RECYCLEDPAPER K I Architectural Engineering Consultants Mechanical & Electrical Design Services Mr. Greg Denckla February 26, 2004 Dept. of Community Development 75 South Frontage Road Vail, CO 81657 Via: Facsimile (3) pages 479-2452 Re: Bull Crab Low Temperature Dishwasher Hood Exhaust Permit No: M04 -0231 Dear Greg, I would appreciate it if you could review this request for a variance to exclude the requirement for a type II exhaust hood above the low temperature dishwasher per section 508.1 of the 2000 IMC at the Bull Crab Restaurant. The conditions in this particular application which warrants this request for a variance are as follows. Included are the hood manufacture's exhaust capacity calculations for the specific pieces of kitchen equipment that are being installed under the existing 11' long x 48" deep type I exhaust hood. The required exhaust capacity is 2,763 CFM. As the test & balance report indicates the hood system is exhausting 3085 CFM. This is 322 CFM greater than the kitchen equipment's requirements. The dishwasher is located approximately 5' away from the type I hood and approximately 6' away from the cooler compressor's exhaust fan rated at 300 CFM. The kitchen's floor area surrounding the dishwasher and the exhaust hood is approximately 400 sgft. with an 8'-6" ceiling height. This calculates to provide an air exchange in this area of the kitchen approximately every 2 minutes. Because of these air movement conditions as well as the proximity of the dishwasher to the type I hood as well as the exhaust above the walk -in cooler I feel that there will be sufficient ventilation in this area of the kitchen to compensate any heat and the minimal steam rejected from the low temperature dishwasher. Therefore could the requirement for the type II hood be excluded? Should you require any additional information please feel free to contact me at your earliest convenience. Sincerely, Architectural Engineering Consultants 1414 F Robert P. Cummings President / Owner 40801 US Hwy 6 & 24, Suite #206, Eagle -Vail, Colorado 81620 Post Office Boa 8489, Avon, CO 81620 Phone: 970.748-8520 Facsimile: 970- 748 -8521 Email: efan@aec- vaiLcom http: / /www.aec- v2il.com T00' d VZT : TT -00lSZ /ZO TZS8 -8104 -048 siuei tnsuoo 5u i.Aaau i 5u3 •yn..ty Arch. Engineering Consultants 970 - 748 -8521 02118104 04:29P P.001 aec Architectural Engineering Consultants Mechanical & Electrical Design Services 0 2 Facsimile Cover Sheet J Memo: W U To: Company: Phone: Fax: From: Re: A.E.C. Project No: Phone: Fax: Date: Pages including this cover page: Greg, m a m cn WE Greg Denckla 09 Oa Town of Vail Community prnt 479 -2321 479 -2452 Bob Cummings Bull Crab Restaurant 23414 970) 748 -8520 970)748 -8521 February 18, 2004 4 COO o> Uf IRIS! i: O V sya 3 Attached are the revised Test & Balance report data sheets prepared by H -VAC. Brian Topping did not decrease the KE1, it is within the required 10% allowable. We did not decrease KE -1's capacity fortwo reasons. First being the face velocity across the grease filters is right at 220 FPM which is perfiict. Second being as we discussed at our site inspection meeting last week, we wanted a little excessive exhaust capacity to make up for the low temperature dishwasher exhaust. What was revised on this report is the MAU capacity. This was increased to 2,267 which is slightly above design capacity. With the CFM capacity of outsideintroducedthroughRTU-1 & RTU -2, 400 CFM & 300 CFM repectively the total make up air is2,967 CFM. This yields a 4% difference between the KE -1 & the total make up air. This is an exceptable differential for our office and take not exceptions to this report. Thx Bob C. 40501 US Hwy 6 & 24, Suite 5206, Avon, Colorado 81620 Post Office $oat 8489, Avon, CO 81620 Phone: 970 - 748-8520 Facsimile: 970 - 748 -SS21 Email: Stan@aec- vail.com htip: / /www.see- vaill.com Arch. Engineering Consultants H =VAC 970 - 748 -8521 02118104 04:29P P.004 KITCHEN MOOD TEST REPORT REPORT: B11U. rRAR DATE: -J/10104 CLIENT: ADDRESS• ATTN: LOCATION: KT'rCBPW TYPE: SR P A F HOOD MFG: METAT_ PR()D[JCTS SERIAL: -EMIT 29 gS$_1 I EQUIP TD: KE-1 GREASE FILTER INTAKE VELOCITY READINGS 230 250 245 230 213 167 AIRFLOW DATA AVERAGE GREASE YFILTER VELOCITY 222 GREASE FILTER AREA FACTOR 13.9 MEASURED TOTAL EXHAUST CFM 30 DESIGN TOTAL EXHAUST CFM 2800 MEASURED TOTAL MAKE UP AIR CFM 2267 DESIGN TOTAL MAKEUP AIR CFM 2200 SMOKE TEST RESULTS PASSED TEST INSTRUMENTAF. DATA MANUFACTURER MODEL TEST PROBE SHORTRIDGE ADM 870 VELGRID Arch. Engineering Consultants H=VAC. 970-748-8521 02/I8104 04:29P P.00S RECTANGULAR DUCT TRAVERSE REPORT PROJECT: BULL CRAB SYSTEM' MAU -1 LOCATION: KITCHEN AIR TEMP DEG. F. DUCT DESIGN SIZE 15" X 13" SO FT 1.35 FPM 1629 CFM 12200 NUMBER OF READINGS 16 FAN LAW #2 S. P. (in w. g.) 2 ]--.--3 4 5 6 7 8 9 10 1 1944 1930 —. 1467 - 1318- 2 1902 1768 1531 1533 3 2026 1546 1509 1650 4 1900 1617 1523 1656 5 6 7 8 9 10 12 14 15 NOTES: DUCT S. P. (in w. g. ) 0,44" MEASURED FPM 1679 CFM 2267 CFM BY FAN LAW N 2 11 I 12 13 14 is PAGE: 00 Arch. Engineering ConsulTanTs 970-748-8521 H=VAC. PROJECT: BULL CRAB AIR HANDLER UNIT DATA MANUFACTURER ETL MODEL 9ANHODM-6-DC2AC SERIAL ADF 1086 FAN TYPE CENTRIFIGUAL RATING 2000 CFM Q 0.30" ESP STARTER DATA MANUFACTURER I FACTORY INSTALLED MODEL SIZE/THERMAL NO. RANGE SET AT (AMPS) REQ. THERMAL RATING (AMPS) AIRFLOW DATA SUPPLY CFM 022-67 OSA CFM 2267 RETURN CFM ATMOS COOL HEAT NOTES: 0211e104 04:29P P.006 a AIR APPARATUS TEST REPORT UNIT: MAU -1 MOTOR NAMEPLATE DATA MANUFACTURER MARATHON r K.P. 11/2 1725 PHASE FRAME 1 S.F. TYPE 1.15 VOLTS AMPS 115/208-230 THERMALLY PROTECTED 561-1-85 scs 18/19.3-9.0 YES DRIVE DATA MOTOR DRIVE 1VP 4'OD MOTOR BORE 5/8" 1 FP 5OFANDRIVE FAN BORE 3/4" 1 CA33 CORRECT NO. BELTS & SIZE ROTATION DRIVE CHANGE 11VL44 7.4 TEST DATA INITIAL 1300 210 FINAL 1466 210 FAN R.P.M. VOLTAGE AMPERAGE 6.3 7.4 0.51" 01- 7-1) PAGE: 00 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 -479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Job Address: Location.....: 2211 N FRONT Parcel No...: 210311415017 Project No -t>-WSp-z,-o3q 3 PLUMBING PERMIT Permit #: Status...: GE RD Applied..: Issued. . Expires . .: P03 -0151 130S-0,313 ISSUED 11/17/2003 11/17/2003 05/15/2004 OWNER DEBIR2 HOLDINGS LLC 11/17/2003 Phone: C/O VICTOR A. VILAPLANA 750 B ST STE 2100 SAN DIEGO CA 92101 License: CONTRACTOR AST AND MCFERRIN PLUMBING & 11/17/2003 Phone: 970 - 926 -5862 P.O. BOX 1303 EDWARDS, CO 81632 License: 202 -P APPLICANT AST AND MCFERRIN PLUMBING & 11/17/2003 Phone: 970 - 926 -5862 P.O. BOX 1303 EDWARDS, CO 81632 License: 202 -P Desciption: Awaste vent domestic water/ gas piping for resturant remodel Valuation: $32,000.00 Fireplace Information: Restricted: ?? # of Gas Appliances: ?? # of Gas Logs: ?? a „++++++++++++++++++++++++++++++++++++++ ++++ + + +++++++++ +++++ + + + + + + + + + ++ FEE SUMMARY Plumbing —> 4 8 0 . o0 Restuarant Plan Review —> 0.00 Total Calculated Fees —> 603.00 Plan Check —> 120.00 DRB Fee --> 0.00 Additional Fees— > 0.00 Investigation -> 0.00 TOTAL FEES ------ - - -> 603.00 Total Permit Fee - - - -> 603.00 Will Ca11_____> 3.00 Payments > 603.00 BALANCE DUE —> 0.00 Item: 05100 BUILDING DEPARTMENT 11/17/2003 DF Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS of I hereby acknowledge that I have read this application, filled out in full the information required, completed anaccurateplotplan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 479 -2149 QR AT OUR OFFICE FROM 8:00 AM - 4 PM. n - / SIGNATURE OF OWNER OR (CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADOCopy Reprinted on 02 -22 -2013 at 15:13:29 02/22/2013 Statement Statement Number: R030005148 Amount: $603.00 11/17/200302:25 PM Payment Method: Check Init: DF Notation: # 1164 Permit No: P03 -0151 Type: PLUMBING PERMIT Parcel No: 2103 - 114 - 1501 -7 Site Address: Location: 2211 N FRONTAGE RD Total Fees: $603.00 This Payment: $603.00 Total ALL Pmts: $603.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts PF 00100003112300 PLAN CHECK FEES 120.00 PP 00100003111100 PLUMBING PERMIT FEES 4.80.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 a — • I< c Mv w+ a V V —1. U n— Ut V— utr 1 r MUL ;d/ t2 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI {3_ 3136Project #: '' 11 JJl1!! V Building Permit #: Plumbing Permit #: TOWN - -- — - - _ -- -- -- ^-41j;jWn,sPec1yT 75 S. Fnx t ge Rd. VAII, Colorado 81657 t 9 28 -B640 or www. 1 -cvun lYir Parse/ Parcid # (Required if no bldg. permit # is provided above) JoVame: Job Address: Legal Description lot: Block: Filing: Subdivision; 1 Owners Name: Address: , Phone: Engineer: Address: Phone: Detailed description of work: c rwa s r V rl. ci iv vn P `- P 4or Yr-_ z r r i- d 4 J Work Class_ New( ) Addition( ) Alterationp< Repair ( ) Other ( ) Type of Sldg.: Single- femiiy ( ) Duplex ( ) Multi- family ' Commercial (F;tstaurant ( Outer L j No. of l5 fisting Dwelling Units in this building: G No. or Accommodation Units in this building: Is this a conversion from a wood burning fireplaex to an EPA Phase IT device? Yes ( ) Pdo ( ) COMPLETE VALUATION FOR PLUMBING PERMIT (Labor & Materials) PLUMBING: S , dd CONTRACTOR INFORMATION t****** * ** * * ** ** * ** **** :x * * * * * * * * * * * ** *FOR OFFICE USE ONLY*******. k*** * * * + ,A*,, &*j, *e.* RECD NOV 17 2003 Rull Id: 2-04-2004 Inspection Request Reporting TQWb1_0E_ Requested Insjyact Date wednesday,Februavy04.204IInspectionmeanGO Site Address-, 22,'11 N FRONTAGE RD WAIL 2211 N FRONTAGE RD NEC Activity: 1 0303,13 Tyj:*' A-COMM 4ub Ty e: AC0W. Status: ISSUED Coast Type: Occupancy-. Use: V 1-HR InSpA,-e',3- 01. Owner: DEBiR2 HOLDiNGS LLC Prtone: 970-'748-)3?,? Applicant: MATSEN ENTERPRISES Pf Will require pre-Opening inspectkq) ano finnicomment: EH received revised plans 11-12-03 New plan ap Ovel approval. - BCARLSON Comment: NEEDING DRB APPROVAL FIRST BEFORE BUILDING CAN REVIEW THIS PERMIT. CLOCK DGES N04STARTTICKINGFORBUILDINGPERMITUN)'T_ DRI5 IS-SUES HAVE BEEN METE - CDA415 Comment: ROLrf ED TO GREG, BILL C AND MATT FOR REVIEW • DFLORES crrtment: clock started ticking for review on 10;15x03 - CDAM ts ommant: EH has not received a complete a Ication ... Letter send to St-At Bucy I'V17.103 KjF,mtzing requvemen w)6 conditions. Watling for reapply. ; Wil CadscAi GDENC j KLA LINqtgedEnskikqdonJsj 9 item: W BLDG-Final C/O Requester! Time: 08:00 AM 4, A% Requestor: MATSEN ENTERPRISES Ph,,xe :. -(g- 97C',376-2766 r'i k"nea To: GDENCKLA rj Entered By: DGOLDEN K Action: -lime xP: Ln§oectigahL tot rDV_243, j V,em: X BLit- Flaming 12!12103 Arpiovee " Inspector: GrCD x tlon: AP APPROVED Comments: INTERIOR 140iJ LOAD BE WALLS APPROVED. 12124/03 Inspector: GC1) Auior.- FRAMING. P APPROVED Comments: KITCHEN ftern 50 BLDG-Insulation — Aff4QVP9101 A(,Wn AP41PROVEDInspector . GC Own: 60 BLDG-She(rttock Naii A 1W 121155103 ArAiom1P _t_ NR I-JOT READY FOR INSPEC71 1217103 in to Action. PI PARTIAL INSPECTK)N Comments- W 'LLS TO FININSHCEILINGREODTOBE. I H01—IF RATED COWTACT JACK SNOW ARCHT FOR I-181-i- r.' IZIi 9fm ASSEMBLY. A'Air,n: C9PC0RREr_T1OI`IPE'1U1REDInspector* GICO STILL N0'r A.-,F-RCYVE'D. 2 L)WERS, St2' C' OR 2 LAYERS OF 518" REQD. ORComments: CEILINGPROVIDE A OPROVARLE 0 Li,YER ASSEMBLY 41: 2 /2 ,rf Inspector GCD Acfi,,(,,. P! PARTlAt. INSPECTEXI Comments: 12/26iO3 miLAYER RESTARALTff (.'EILING Inscector: GCLI AcJcn: Fi PAR i' IAL 11,4SPECTION Comments: REfSTARAUN'r SOF117 : ^ND RFSTROCKA CEILINGS. 12130/03 InSPfid01: cdavis Ntioji: At' APPRO'R-ID Comments, rest ceill and walls con, pleted 2 layers WWtype x us#a*i on ceiling Item: 70 BLDG-Mist. item. 90 BLDG-Final Approved 01-28-2004 Inspection Request Reporttnq Page 4 7.38 am Requested Inspect Date; Wednesday, JanuaryU,20,, 4Insfeetlon !'area; GE? Eft Address,. <None Listed., 221 1 N FRONTAGE RD kPID Information Activity: PDXW51 T° w: &PLhAS 'Sub 1 Acom Status: ISSUED Occupancy- C(,,,nst Type: L Insp Area: GO Owner: DEBIR2 HOLDINGS LLC Applicant: AST AND W—'FERRIN PLUMBING & HE Phone: 970-926-5862 Contractor: AST AND MCFERRIN PLUMBING HE Phone* 970-926-5862 Description: Awaste vent domestic wateugas piping for rAsturrar.-t renx-del R. Uested lnspection(si Item: 240 PLMB-G"-tl PAlinMUMBING Requested Time. 08,00 AM ILI Requesto-: AST AND MCFER & HE Phone: 970-926-5862 -or- 904 Assigned To: GUENCKLA 5402 Entered By: CC-rOLDEN KAction: Time t.xp: Iteir Comments: C-0WlL;;PIPE 15psi TEST, WATER HEATER GAS PIPE l5psl TEST History Item: 210 PI-M&Underground Approved 11; 25103 Inspector., GCD Action: AF APPROVED Comments: UNDERGROUNDDMANI)GREASL LINE FOP. KITCHEN, DWV FOR PAR RESTRolom FLOOR DRAINS. BAR AREA AND WAIT STATION BY KITCHEN. Spsi TEST. Aem. 220 PLMB-RougK'D.W.V. Approved 12/12/03 Inspectoc GCO Actor): PI PAPTIALINSPECTION' Comments: BAR AND REs,rROOM DVVFV FLOW TEST 12122103 Inspector: GCD Action', APAPPPOVED Comments: HAND SINK FLOW TES Y. item: 230 PLMP-RouqhtWater Approved 11125103 Inspector: t,CD Action: AP APPROVED Comments: UNDERGROUND SOFT COPPEF WATEP LINES BAR AND KITCHEN. NO JOINTS NC TLST 12/11/03 Inspector: GCD Action: PI PARTIAL INSPECTION Commence: WATER PIPE FOR SAP. RESTROOM AND WAIT STATION 100psi TEST, 12/22,'03 Inspector: GC[l, Action; AP APPROVED Comments: MAIN WATER SUPPLY I 1:Cpsj TEST KrTCHEN WATER PIPE 100psi TES".-. Iters: 240 PLMB-Gas ftminq 11 Ap;xovem " 12122,103 Inspector: GCD Ac4ion: AP M-,PROVED Comments: COOK LINE C-44S PiPE 16ps! TE!;T, WATER HEATER GAS PIPE ISpsi TESI Um: 250 PLIV13-P6otlHol Tub item: 260 PLMB-M-st- ftonv 290 PLIAB-Final E03 -0226: Entries for Item: 190 - ELEC -Final 15:12 02/22/2013 Action Comments By Date Unique_ Ke APPR eg 01/27/2004 A000069 256 Total Rows: 1 Page 1