Loading...
HomeMy WebLinkAboutP04-0032TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 OWNER DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Job Address: 680 LIONSHEAD PL VAIL Location.....: Antlers of Vail PooUDeck Parcel No...: 210107206001 Project No : �;� � j- c:� y ��� VAIL/LIONSHEAD CORP 680 W LIONSHEAD PL VAIL CO 81657 License: CONTRACTOR TOTAL PLUMBING 4701 N. COLORADO BLVD DENVER, CO 80216 04/16/2004 Phone: Permit #: Status . . . : Applied . . : Issued . . : Expires . .: PO4-0032 �_�;�r _ �:C;�.��_ ISSUED 04/16/2004 OS/03/2004 10/30/2004 04/16/2004 Phone: 303-393-7271 License: 110-P APPLICANT TOTAL PLUMBING 04/16/2004 Phone: 303-393-7271 4701 N. COLOR.ADO BLVD DENVER, CO 80216 License: 110-P Desciption: 2 NEW BATHROOMS, HOOK UP POOL EQUIPMENT Valuation: $53,100.00 Fireplace Information: Restricted: ?? # of Gas Appliances: ?? # of Gas Logs: ?? # of Wood Pallet: ?? ****�*r**�s*x*:�***►*►**�*t*s*s*►*s�r*ss�***r*rsts**r**s*r*�r**r*rt**e* FEE SUMMARY **s�sss**r:t�a*r�*****x*r*****�****�r***�*►r**��****r***�***� Plumbing---> $ 810 . 0 0 Restuarant Plan Review--> $ 0. o o Total Calculated Fees---> $1, 015 . 5 0 Plan Check---> $202. 50 DRB Fee---------------------> $0. 00 Additional Fees-----------> $0. 00 Investigation-> $0. 00 TOTAL FEES--------------> $1, 015 . 50 Total Permit Fee----------> $1, 015. 50 Will Call-----> $3.00 Payments-------------------> $1, 015.50 BALANCE DUE---------> $ 0. o 0 *�**�*rr�***►*r*+s*s:�*�*+*************�***:r*s*�*ssr*****�rr*r****�r*********r�*rs***�s:e►*«�***�s**�:*�**s*rrrr***�*srr***rr***rr**a**�s*s**r***r*� Item: 05100 BUILDING DEPARTMENT 04/26/2004 JRM Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ****�+*�*�*�*****:*****�******:*..�«****.**�**�..:.******.**�*s.:�:.«**«�«.*�s****�:*..***.**�:.:�*******:�«�***��**.*:*:*.*�*.*�*.**.*�********�* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAI)iCE BY SIGNA 149SJR AT OJd'k OFFICE FROM 8:00 AM - 4 PM. OR CONTRACTOR FOR HIMSELF AND OWNEF ****+***���**********+********************************�*********************+�+�+*�**�***�** TOWN OF VAIL, COLORADO Statement *************:x*******�:******************************+*********************�:***************** Statement Number: R040005734 Amount: $1,015.50 05/03/200402:35 PM Payment Method: Check Init: DDG Notation: Total Plumbing 1122 Permit No: PO4-0032 Type: PLUMBING PERMIT Parcel No: 210107206001 Site Address: 680 LIONSHEAD PL VAIL Location: Antlers of Vail Pool/Deck Total Fees: $1,015.50 This Payment: $1,015.50 Total ALL Pmts: $1,015.50 Balance: $0.00 ***:�:��x*******************************�x******************�x�x************�*�*******:x*********** ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 PP 00100003111100 WC 00100003112800 0 Description ------------------------------ PLAN CHECK FEES PLUMBING PERMIT FEES WILL CALL INSPECTION FEE Current Pmts 202.50 810.00 3.00 PO4-0032: Entries for Item:290 - PLMB-Final 09:09 02/26/2013 Comments Total Rows: 1 By Page 1 A000073 649 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED n`T-n� �( ��/� Project # • ��J (J `i T ` Building Permit #: - C7G .%z- �� Plumbing Permit #: � I O � �, 970-479-2149 (Inspections) V ?1DR'N OF �AIL � TOWN OF VAIL PLUMBING PERMIT APPLICATION 75 S. Frontage Rd. Vail,Colorado 81657 /��✓O,c,� � CONTRACTOR INFORMATION v v VALUATION FOR PLUMBING PERMIT (Labor & Materials) PLUMBING: $ �� �� �:���**�:*���,���*�����*���,������,���,��,��*�FOR OFFICE USE ONLY��,�����**�**������:�����:*,������,��,���x� ier Fees: Date Receiveci: B Pees: Acce ted B: - nner Sian-off: _,�"1 r,�'�...�,�,�.z �'l'1^`- (�`'`'` ld. ` ��- C� `�,- RECEIVED . �� \\Vail\data\cdev\FORMS\PERMITS\PLMBPERM.DOC 07/26/2002 ¢,�` � u APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED ��,, -, , Buildina Perm►t # �%� ' ��-�� 970�79 2149 �Inspections) �� TOWN OF YAIL '' REVISION'TO TOWN OF VAIL BUILDING PERMIT 75 S. Frontage Rd. Vaii, Colorado 81657 CONTRACTOR INFORMATION Genera Co tr tor: Town of Vail Reg. No.: Contact and Phone #'s: `, Cz.., � l �k..lii� _- ATTENTION: JR, CHARLi , R S',; DORIS Contractor Signature: COMPLETE REVISED AMOUNT: $ PLUMBING: $ D VALUATIONS FOR PERMIT (Labor & Materials ELECTRICAL: $ MECHANICAL: $ OTHER:$ REVISED TOTAL: $ For Parcel # Contact Ea le Counf Assessors Oft'ice at 970-328-8640 or visit www.ea le-count .com Parcel,# � f� � (�7 � C: G� Job Name: Job Address: - ,u� �� y��� Legal Description Lot: Block: Filing: Subdivision: Owners Name: Address: Phone: ArchitecbDesigner: Address: Phone: � Engineer: Address: Phone:. � REASON FOR REVISIONS: :� ��> � �Z�.1 UL �. � -LL�'�'�.� ._ **'`****''***'`*********'"`*********ROUTlNG INFORMATION FOR OFFICE USE ONLY******'`***************''************* BUILDING DEPARTMENT: PLANNING DEPARTMENT: 'ROUTED TO: .- . ; - �tOUTED TO: ; �; ..�.. �.." '�-DRB REQUIRED. ;Y•'0R N ; ` : DATE ROUTED: ; . DATE;ROUTED _ --'Planner Sign-off:. � DATE RECEIVED: , `Da iv d: . �� , , , � ,� �� � . �>L� �'� �11� � ��� ����i�.G�� �� � C:\windowsl0esktoplDFLORES INFO\Revised Bldg permit.doc 10/16/2002 t � TOwNOF YAI� ' Department of Community Development 75 South Frontage Road Yail, Colorado 81657 970-479-2138 FAX 970-479-2452 www. vailgov com June 8, 2004 Mr. Bob Cummings P.O. Box 8489 Avon, CO 81620 Dear Bob: This letter is to confirm receipt and approval of your letter dated June 7, 2004 regarding the design for the subdrain and sump pit for the Antlers pool, permit PO4-0032. With regard to the use of the Studor Vent for the subdrain and the sump pit, an atmospheric vent is still required per the manufacturer. After talking with Scott with Total Plumbing there may be some difficulty in running the venting due to conflicts with structures above, keep in mind that vents can be terminated on a side wall per the 2003 International Plumbing Code (IPC) section 904.6; this may help in the venting for the sump and floor sink. Valves are required on the discharge piping of the sump pumps per 2003 IPC section 712.2. I will make these red line notes on the plans provided and approve them. Someone will need to pick these up and have them in the field for subsequent inspections the plans will be ready late this afternoon. Ve Trul ours, Greg e ck a Town f Vail Plans ExaminerBuilding Inspector , � � � RECYCLED P�I PER � 1 � TOwN OF VAI� ` Department of Community Development 75 South Frontage Road Yail, Colorado 81657 970-479-2138 FAX 970-479-2452 www. vailgou com June 7, 2004 Mr. Robert Cummings Architectural Engineering Consultants P.O. Box 8489 Avon, CO 81620 Plumbing Permit PO4-0032 Antlers Pool Dear Bob, I agree with your assessment that the lower level below grade waste piping is not an indirect waste. It is a building subdrain per the 2003 International Plumbing Code (IPC) section 712.1. As such it would be required to be trapped and vented in accordance with section 3013 general requirements. In addition the sump pit doesn't comply with the IPC section 712 which requires that sumps be tightly covered and vented. It has not been demonstrated that the plumbing system you have proposed meets the minimum code requirements of the IPC. Your options are to design and build the plumbing per the International Plumbing Code, submit a design for consideration as an alternate method or material with supporting documentation and relevant code sections per IPC section, 105.2, or submit an engineered design with supporting documentation and relevant code sections per IPC, section, 105.4. Orice this has been submitted, the building department will review it, to determine that the alternate is the equivalent prescribed by the code and meets the intent. Ver Trul ours ;;' � ..����r reg �. ckla Town o Vail Plans ExaminerBuilding Inspector � � RECYCLEDP.IPER ��� Architectural Engineering Consultants Mechan�cal & Ercctrical Design Services Mr. Greg Denckla Town of Vail Community Development 75 South F�ontage Road Vail, C� 81657 Re: Antler Pool Remodel AEC Project No: 24435 Dear Greg: June 7, 2004 Via: Facsimile (3) pages 479-2452 1 appreciate your timely review and response to my request for deleting the traps and vertts on the lower level floor drains. I received your letter this aftemoon clarifying the code requirement for traps and vents on all of these fixtures that were indicated on the original documents. In turn I have informed Total Plumbing that the traps and verrts are required and they are going to install them per the documents in compliance with the 2003 IPC requirements. Secondly the attached sketches depict revisions to the sump pit arrangement to comply with section 712 of the code to be tightly covered and vented. The open top sump was a request from the poot designer. Upon your review and approval of these revisions I will issue these sketches to all of the appropriate contrac#ors for construction. If you need any additional information please feel free to call. Sincerely, Architedural Engineering Consultants ���"� ��� � � President ! Owner T4A�V APPROV''ED Communiry Development Dep :rtment Building Safety & In3��ctio� Service3 $ectfon l06.4.3, Uniform BuildWg Code, Validity of PeirmiG The issuance or granting of a permit or approval of plaos, apecifications and comput�iait shall not be conswed to be a pertnit for, or an approval of, any violation ot any of chc pr�visioras of etris code or of any odur ordinance of du jurisdictioo. permits presur.i�; ro give authority to violate or cancel the pmvisions of thi� Code or other ord:ncr.ce� of the jurisdiction shall not be valid. The issuance of a re�TSt based on ptans, specifications and other data sh�ll not preveat the buitding official from thereaftar cequiring the correction of Cnors in said plans, specifications and other data, or from preventing building opecations being can'ied on thereunder when in violation of this code or o[ any other ordinances af ctu�diction. {NITIALS: �..�...--- DATE: ���' � 40801 US Hwy 6& Z4, Ste #214 Avon, Colorado 81.620 Post Of#ice �ox 8489 Avon�, Colorado 81620 Phone: 97Q-748-8520 Facsimile: 970-748-8521. En�ail: xL;►r►(a�.:��C-v:iil.co�n Web: www.�ec-v�il.cum 't00'd H90�60 t0180190 TZS8-8�bL-0G6 s�ueitnsuo� 6ui.Aaaui6u3 •y�..+d N 0 e a ¢ (D O m 0 � 0 . � m � � m � N N m i � � N m � � � r C N r 7 N c 0 U rn c .� w w c .� c w L U � a t �� t • � . 3' DlSGNRR6E LINE; TO MAIN GiTY 5Ei'�12R �F�RENGE P�.1 FOR GDNTIWATION �' VENT UP PR�VIDE STUD�OR VENF INGOMINb POWeR�� TD FLOAT t PUMPS 36•m SEN.ED 50t.tD GO'V�R — 36'�D x 48' DEEP - GONCRETE �AS1N FLOAT 5N0TGt�5 l.HEC+� VALVES �- ve�'r � r�ovi� 5TUDiOR VENT � t I i PU°IP S�RVIGE I GOUF'LINb � _ �� � FL40R NR I 5FUVNE� ` f'AP I . . _ � . . '_��. � W �5 6ALLON 6AC.iCWASH TAI� t DRNIN B'f THE POOt lANTRAGTOR `- FIT115HED FLO�OFt ��°t��� '' . . -;���v �F 3' W FR.A� FLOOR DRNNS StNPLEX 5UMP Pa71MP� t, O�`� �•� IF. =32` 6ElOW 5LA6. PRUVIDE �O1': �� A SCREEN QN tHE EI� OF THE PIPE �"�T PU"�P p�l ELEVATED ,�� ; ab GAGE r �UPL�X SUMi° P1JMF' SE- I��T�i L�: �o�_ NO SGALE Architectural Engineering Consultants bl�►�.ical & Electrica] Des;�n Serv:ces PO Booc 8a89, 408Ut 11S Hwy 6& 24, Ste 214, A��on, C�, B 1620 Telephc�,e: 9747�5-8520 Fax:970.74&8521 w�ww,aao-va�.00m P�RT I �L PLIJMBI �iG SGHED.ULES SCAL E: NONE DATE� JUNE '1� 2p04 DRAWI� BYa RP.G. AEG PRO.lEGT a 23406 PROJEGT: : ANTLER�S POOL'REMODEL '. ADDENDUM NO. 2 ' T i°SK-I m m a a a t� m �i a � 0 . � 0 � � m � N � � � m � � i e m N r C N r 7 N c 0 U m c .� v w c .� � w r U � Q �.i � � � C , -�� *,+; � �` � �'� � ;��v��a��6 •�<< � �� c� a��: .._ � T � � :� PP Pq�Ui�1T I K GONGRETE- PIT PF' SEE DETAIL B ON P-1.1 36"m x48' DEEP GONGRETE BAGKWASH F�ooR 5t� ftlT W/ _ �fD C.OVLR FILTER - RAGK SYSTEM Architectural Engineering Consultants I►techanic.�1 & IIecitual Desigi Sen'ia�.s PO Box 8489, 40�01 US FIv�y 6& 24, Ste 2 i4, Avoo, CO, 81620 T��noce: 97Q749-8�20 Fax: 97Q748-8521 vr�w_aec•vaiLrnm �y�. 14 14 3� AL�' DI AM X�" L UPRI HT S��ORAC�E TAPtK ' TLE ANp �VE TAPkK 'RE�T � 8" THt K 4'-0'�4'-O" GONG. PAD B T PQOL EQVIPMEtaT GONT TOf� � � �- � � �� i � 1 i �/ � l. I . F�- I 4° � J� . i �+— 3" MG � � I��O� � � l�� I���I���I �� �s � - � FD-I I �. . � _ f��4RT I �L LOV�lER LE�/�L PLIJMBI �lC� �L A��1 SGALE: I/4" ■ {,,m" I�tTH � �h. � / ' ` FI 1 ' � E: I E I PI � I 5f � l� I, � �" / �� � I �+ 1 I I I / / �;` ` // NE . � / EXI��TING I�' � �� DATE� .l,R�IE l, 2D04 DRAWN BYa RPG AEG PROJEGT a 2233�1 PR0.IEGT� ANTLER5 GONDOMINIVM POOL ,RENOVATIDN ADDENDUM NO. 2 T I—�,� Arch..Engineering Consultants 970-748-8521 06/04104 04:12P P.001 aec ,A►rchitectural Engineering ConsuYtants Mechan�cal & Electrical Design Services June 4, 2004 Mr. Greg Denckla Town of Vail Community Oevelopment 7fi South Frontage Road Vail, CO 81657 Re: Antler Pool Remodel AEC Project No: 24435 Dear Greg: After our discussion this morning and upon further review ofi the waste piping layout and sump pit detail for the lower level floor drains on the above referenced proje�t I would appreciate it if you could reconsider your �equirement for these floor drains to be individually trapped. The letter that I forwarded o Tu sday depicting the lower I�vel below grade piping as an indirect waste probably was�``�curate description of its function, In this unique application I would like for you to consider the sump pit with its open grate top to function as the waste piping's trap and vent. The addition of a second trap at each floor drain would be double trapping the fixtures, which is not acceptable by the IPC. Additionally, the sump pit's pump float will be mounted at an elevation below the invert elevations of afl the fixtures to insure that the water level in the waste piping will never back feed up to the finished flovr elevation eliminating the possibility flooding. After you've had a ehance to review this request I would appreciate it if you could notify me as toward your interpretation of this piping application a r+ve(I as if you require any additional information. Sincerely, Architectural Engineering Consultants J l'� v"_' � �� . a�� President / Owner 4080� US Hwy 6& 24, Stc #214 Avon, Color'Ado 81620 Post O�cc Box 8489 Avon, Colorado 81620 Phone: 970-748-8520 Facsimile: 970-748-852X Email: stan�acc-vail.c�m Web: www.�ec-vail.com Arch. Engineering Consulta�ts 970-748-8521 06102t04 0�:25P P.001 r • , � Architectural EngYneering Consultants Mecl�anical & ElectrYCal Design Services _. Facsimile Cover Sheet / Memo: To: Greg Denckla Company: Town of Vail Community Development Phone: 479-2321 Fax: 479-2452 From: Bob Cummings Re: Antlers Pool Remodel A.E.C. Project No: 24435 Phone: (970) T48-8520 Fax: (970)748-5521 Date: June 2, 2004 Pages including this 2 cover page: Greg, Per your request the tollowing documents a reviston to the ptumbing documents which deleted the requirement for traps on the lower leve� floor drains which are indirectly drained iMo the sump pit with an air gap. Per Chapter 8 section of the 20Q3 IPC the irap shall be locate in the wasie receptor, i.e. the sump pit in indirect drain applications with an air break. Thx 8ob C. 40501 US Hwv 6& 24, Suite #206, Avon, Color�do 81620 Post Officc Sox 8489, Avop, CO 81620 Phone: 970.745-8520 Fac�iutile: 970-748,8,�21 Email: stan@a�c•vail.com http:l/�www.aee-vAil.00m .. � � N m B � 0 ti N B ti fD m � N � � i � d� � i m r � N r C N r 3 N � 0 U m c .� v w c .� c w L U � Q Architecturai Engineering CansuItants bRech�icat & �ectricalD�s:gn S�vices PO Sox &189, 44801 I1S Hwy 6 8t 24, Ste 214, Av�, (.`U, S 1620 T�pt,ane; 97a�se-s52o Fax� �a�as-sszi a�,w.aeo-vail.00� P�rRTI � LE�EL � ���1� SGAL E: I/ /A� � ��. ��- WER lJj�� DATE. MAY 2, 2004 � @Y: � AEG PROJEGT � 22334 PFZ0.IEGT: ANTLERS GONDOMINIl1M POOL RENOVATION 1 �.I *****************************************************************************+*��*********** TOWN OF VAIL, COLORADO Statement **************************************************************************+**�:�*******�***** Statement Number: R040005992 Amount: $80.00 06/10/200408:11 AM Payment Method: Check Init: DDG Notation: Total Plumbing 1124 Permit No: PO4-0032 Type: PLUMBING PERMIT Parcel No: 210107206001 Site Address: 680 LIONSHEAD PL VAIL Location: Antlers of Vail Pool/Deck Total Fees: $1,095.50 This Payment: $80.00 Total ALL Pmts: $1,095.50 Balance: $0.00 **********************************************************************************:x********* ACCOUNT ITEM LIST: Account Code PF 00100003112300 Description � PLAN CHECK FEES Current Pmts 80.00