HomeMy WebLinkAboutP01-0040TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
Job Address:
Location.....:
Parcel No...:
Project No :
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT
288 BRIDGE ST VAIL
210108244003
OWNER ROSENQUIST,RICHARD N.
SELBY, CHARLES
385 CLAYTON ST
DENVER CO 80206-4228
License:
CONTRACTOR SCHNEIDER MECHANICAL
P.O. BOX 7314
AVON, CO
81620
- BROW05/21/2001 Phone:
Permit #
Status . . . :
Applied . . :
Issued . . :
Expires . .:
05/21/2001 Phone: 970-827-9443
License: 113-P
APPLICANT SCHNEIDER MECFiANICAL 05/21/2001
P.O. BOX 7314
AVON, CO
81620
License: 113-P
Desciption: Joe's Famous Deli - Add window, upgrade stairs
Valuation: $2,000.00
Phone: 970-827-9443
PO1-0040
ISSUED
OS/21/2001
OS/21/2001
11/17/2001
Fireplace Infonnation: Restricted: ?? # of Gas Appliances: ?? # of Gas Logs: ?? # of Wood Pallet: ??
**********s*ss**s********»****�r*****r*�:******a+*«******s��*********► FEE SUMMARY �****�*****��*t******s*sx�*�**�*r****************►s*****�**�
Plumbing---> $3 0. 0 0 Restuarant Plan Review--> $ o. o o Total Calculated Fees---> $4 0. 5 0
Plan Check---> $ 7. 5 o DRB Fee---------------------> $ 0. o o Additional Fees-----------> $ o. o 0
Investigation-> $0.0o TOTALFEES--------------> $40.50 TotalPerntitFee----------> $40.50
W ill Call-----> $ 3. 0 0 Payments------------------> $ 4 0. 5 0
BALANCE DUE---------> $ o. 0 0
*�***s*�**+*r*s�***ea+*+►*aa*e*****►a**e**r*►a*«****r********�****r******t******t**�**►**►******$*******s***s****�*a***r*a*+*as****sa****s**s*s*s
Item: 05100 BUILDING DEPARTMENT
05/21/2001 DF Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
:**.**.***.**.*..*.+:**�**:**�*********************.**.*****...**�**.**.«**.*****.*****...**�*********+**********, **********....***.:**.*..**.***
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and
state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved,
Uniform Building Code and other ardinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV
BY TEI�PHONE AT 479-2138�R AT OUR QFFICE FROM 8:00 AM - 5 PM.
SIGN�'�'�[JRE OF OWNE� (�R CON��2AC OR FOR HIMSELF AND OWNE
********************************************************************************************
TOWN OF VAIL, COLORADOCopy Reprinted on OS-21-2001 at 13:36:51 OS/21/2001
Statement
********************************************************************************************
Statement Number: R000000798 Amount: $40.50 05/21/200101:36 PM
Payment Method: Check Init: DF
Notation: CHECK # 4484
-----------------------------------------------------------------------------
Permit No: PO1-0040 'I�rpe: PLUMBING PERMIT
Parcel No: 210108244003
Site Address: 288 BRIDGE ST VAIL
Location:
Total Fees: $40.50
This Payment: $40.50 Total ALL Pmts: $40.50
Balance: $0.00
********************************************************************************************
ACCOLTNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 7.50
PP 00100003111200 PLUMBING PERMIT FEES 30.00
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
��� l -- o I ��
Thursday, May 17, 2001 12:28 PM Schneider Mechanical 970 827 9046 p.02
� �� � � ,
. , _ � ��� .
� APPf.iCATiQN WILL N07 B,E ACCEPTED Y� iNCOMPProj� �N E1�I1 ��- /1l � r1 �
I' J� C' ��
� . Building Permit #: .�1°2 G t - ��a
�i Plumbiag Permit #:
. � 970=479=214'9 (Inspections)
7�DWNOFYAb N OF VAIL PIUMBI G PERMIT PPLICATION
75 S. Frontage Rd. �
Vaii, Colorado 81657
�
Cantractor:
�
COMPLETE VALUA
PLUMBING: $
Conbct Ea Ie County Assessors
P�rcel #{Required if no bldg. �
]ob Name: �p�i� �L�
Legal Description � Lot:
Owners Name: �C"'r,o ;T
Engineer: N��,
Detaited ed stription of work:
�n af Vail Reg. No.: Contact
FOR P M NG PE {L
.�` .
61ock: Filin9:
� s
Address:
�``~' __—y�
#'s: ( R
�
Materiais)
Gww. ea � aun , com for Parce/ �
Z� oS z �fov3
� � � ���£ S; . � �_ �
Subdivision:
�� Phone: ��� .
Work Class: New ( ) Addition ( } Alteration ) Repair ( ) �ther { )
7ype oP Bldg.: Single-famify () Duplex () Multi-family () Commercial ) Resraurant ) Other ()
No. of Existing Dwelling Units in this build'+ng: /i� � No. of Accommodation Units in this building:
Is this a conversion from a wood buming fireptace to an EPA Phase II device? Yes () No (
�.
**�,�x�*;.x**�*�*�x*�f*�*x,�*�**,�x�*x+x�**FOR OFFICE USE ONLY�x�x**,�x,�*x�x�,�,���,�**��*x�*****�r�**fa*�
Other Fees: Date Received•
DRB Fees• A B . .
Pfanner Si n-off• - -
F/everyone/Forms/plmbperm
P01-0040: Entries for Item:290 - PLMB-Final 15:41 02/27/2013
Action Comments By Date Unique_
Ke
qp JRM 11/23/2001 A000053
947
Total Rows: 1
Page 1
JOE'S DELI
NON-DWELLING OCCUPANCY
RESTAURANT
3 PHASE 208 VAC
KITCHEN SERVICE AND FEEDER
ELECTRICAL DEMAND SUMMARY
Prepared By: Rader Engineering, Inc.
Thomas W. LaVenture, P.E.
6/29/01 13:11
Notes:
1. This Service and feeder supply the new circuit breaker panel for commercial kitchen equipment.
2. The equipment load information for this calculation is as provided by the client and is not otherwise certified.
3. See attached sheet for equipment load information details.
4. This calculation is made per NEC Article 220-20
5. Circuit loads are to be balanced between phases.
6. Full size neutral conductors are required for this service and feeder.
Demand Load Calculation
Thermostatically Controlled and
Intermittant Use Equipment
Other Equipment
(Heating, Ventilating, Motors)
largest Motor
CALCULATED DEMAND
UTILITY TRANSFDRMER
500 KVA, z.3% IMPEDANCE
208Y120 VAC, 3—PHASE
60,344 AIC
DEMAND
AMPS FACTOR
174.4 65% 113.4
36.88 100% 36.9
23.5 25% 5.9
156.1 AMPS
RE
��
y�V� � �\�t`
�trBN�
��`S �/" �' � �--�
� -- Z i - Z�c� I
K•��•1[•�-:�
. �
JUL - 2 2001
TOV-COM.DEV.
3 X 4/0 AL PER CONTRACTOR
180 AMPS MAX, NEW
ALL BRANCH CIRCUIT PANEL
BREAKERS SHALL HAVE
MINIMUM 42kAIC
SERIES RATING
O
�
L 42kAIC RATED MAIN
27,566 AIC
USER
SHALL
NOT
EXCEED
180 AMPS
DEMAND