HomeMy WebLinkAboutB96-0164 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PROJECT TITLE:
NEW (SFR,P/S,DUP) PERMIT Permit #: B96-0164
Job Address: 2763 KINNICKINNICK RD VAIL Status . . . : FINAL
Location.....: 2763/2765 KINICKINICK RD Applied . . : 06/20/1996
Parcel No...: 210314303001 Issued . . . 07/18/1996
Project No : ?? Expires . .: 10/10/2008
APPLICANT CARPENTRY UNLIMITED, INC 06/20/1996 Phone: 3039263753
141 E. MEADOW DRIVE
� VAIL, CO
81657
License: 107-B Also is CONTRACTOR
CONTRACTOR CARPENTRY UNLIMITED, INC 06/20/1996 Phone: 3039263753
141 E. MEADOW DRIVE
VAIL, CO
81657
License: 107—B Also is Applicant
OWNER STERIO ROBERT W & DENYSE E 06/20/1996
2633 KINICKINICK RD
VAIL CO
81657
Desciption: NEW DUPLEX
Occupancy Type Factor Sq Feet Valuation
Dwellings Zone 1 V-N 58 . 70 4, 561 $267, 730. 70
Private Garages Zone 1 V-N 21 . 30 640 $13, 632 . 00
Totals. . . 4, 561 $281, 362 . 70*
Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: $281,362.70
Fireplace Information: Restricted:Y !�of Gas Appliances' 0 #of Gas Logs: 2 #of Wood Pallet: 0
+►*s***�+#+s*+�*s*+**►*+*�r+«***►*******+********s►**�***++►+*as��**►+ FEE SUM MARY •*+►**s+***�*+*++x+s►+*++*fs+as*+*sa*et*+**as**a�*�s�*�*+►*s
Building------> S1,968.00 Restuarant Plan Review--> S0.00 Total Calculated Fees-----> S3,809.35
Plan Check---> 5959.20 Recreation Fee------------> 5689.15 Additional Fees------------> 50.00
Investigation-> 50.00 TOTAL FEES-------------> S3,809.35 Total Permit Fee-----------> S3,809.35
Will Call-----> 53.00 Payments-------------------> $3,809.35
BALANCE DUE---------> 50.00
#####*#i�###**#####+k4#f#t#44*�k4#****tt*###*#+F►�**#*t**###+Fk####t#*#f►######*�F*t*###**t**##t#*�#**##*###t###�k#M*�###*###f#R}##�RI*##M##*#f####*i***4
Approvals:
Item: 05100 BUILDING DEPARTMENT
06/20/1996 CHARLIE Action: NOTE PLANS TO DAN
07/10/1996 CHARLIE Action: APPR
Item: 05400 PLANNING DEPARTMENT
06/20/1996 CHARLIE Action: NOTE PLANS TO GEORGE
07/10/1996 GEORGE Action: APPR
Item: 05600 FIRE DEPARTMENT
06/20/1996 CHARLIE Action: APPR N/A
Item: 05500 PUBLIC WORKS
06/20/1996 CHARLIE Action: NOTE PLANS TO LARRY P
07/17/1996 LARRY P Action: APPR LARRY PARDEE
Item: 05550 ENGINEERING CIVILS
06/20/1996 CHARLIE Action: NOTE PLANS TO TERRI
07/17/1996 TERRI M Action: APPR NEW SITE PLAN BY GREG H
4*f*##►Rfi4rt*###*#i#i######i#��*�*t*�ttt#############f#4#*�R##R*�#**#*##�*#*#*t**#t####�####4i*##*R***t#t##f#####4**####f#f##►}t#i#i###�4#*****i#t
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit#: B96-0164 as of 02-28-2013 Status: FINAL
********************************************************************************************************
Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 06/20/1996
� Applicant: CARPENTRY [JNLIMITED, INC Issued: 07/18/1996
Job Address: 2763 KINNICKINNICK RD VAIL
Location: 2763/2765 KINICKINICK RD
Parcel No: 210314303001
********************************************************************************************************
CONDITIONS
********************************************************************************************************
Cond: CON0001279
NO MECHANICAL,ELECTRICAL, OR PLUMBING WORK ALLOWED UNTIL PERMITS HAVE BEEN
AQUIRED
Cond: CON0001280
Public Works sign off required per DRB condition of approval
Cond: 33
(PLAN)THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL
BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.
Cond: 10
(PLAN): ATTIC SPACES SHALL HAVE A CEILING HEIGHT OF 5 FEET OR LESS, AS MEASURED
FROM THE TOP SIDE OF THE STRUCTURAL MEMBERS OF THE FLOOR TO THE UNDERSIDE OF
THE STRUCTURAL MEMEBERS OF THE ROOF DIRECTLY ABOVE.
Cond: CON0001281
CONTRACTOR NEEDS TO COMPLY WITH SITE PLAN REVISED BY GREG HALL. CHECK
ELEVATIONS AT FRAMING TO DETERMINE ANY PROBLEMS WITH DRNEWAY GRADE
******+******�*******�**+*******�****************�***+*+********************************�***
TOWN OF VAIL, COLORADOCopy Reprinted on 02-28-2013 at 15:09:51 02/28/2013
Statement
*************�*�*�*�*******************************************�*********************+******
Statement Number: REC-0172 Amount: $3, 609.35 07/18/199609: 18 AM
Payment Method: CK Init: CD
Notation: #1872
-----------------------------------------------------------------------------
Permit No: B96-0164 Type: NEW (SFR, P/S, DDP) PERMIT
Parcel No: 2103-143-0300-1
Site Address: 2763 KINNICKINNICK RD VAIL
Location: 2763/2765 KINICKINICK RD
Total Fees: $3, 809. 35
This Payment: $3, 609.35 Total ALL Pmts: $3, 809.35
Balance: $0.00
****************************************�***********+*****r*****************************�*+*
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
AD D2-DEP08 CLEANUP DEPOSITS 500.00
BP 00100003111100 BUILDING PERMIT FEES 1, 968 . 00
PF 00100003112300 PLAN CHECK FEES 954 .20
RF 11100003112700 RECREATION FEES 684 . 15
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S . FRONTAGE ROAD -
VAIL, CO 81657
970-479-2138
NOTE : THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PROJECT TITLE : STERIO�BRADLEY DUPLEX
NEW ( SFR,P�S,DUP) PERMIT Permit # : B96-0164
Job Address : 2763 KINNICKINNICK RD Status . . . : ISSUED
Location. . . : 2763�2765 KINICKINICK RD Applied. . : 06�20�1996
Parcel No. . : 2103-143-03-001 Issued. . . : 07�18�199b
Project No. : PRJ96-0104 Expires . . : O1/14/1997
APPLICANT CARPENTRY UNLIMITED, INC Phone: 3039263753
141 E . Meadow Drive, Vail, CO 81657
CONTRACTOR CARPENTRY UNLIMITED, INC Phone: 3039263753
141 `E . Meadow Drive, Vail, CO 81657
OWNER STERIO ROBERT W & DENYSE E
2633 KINICKINICK RD, VAIL CO 81657
Description:NEW DUPLEX Number of Dwelling Units : 002
Occupancy � Type Factor Sq. Feet Valuation
Dwellings Zone 1 V-N 58 . 70 4, 561 267 , 730 . 70
Private Garages Zone 1 V-N 21 . 30 640 13 , 632 . 00
Subtotal : 5, 201 281, 362 . 70
Table Date : 05�17�1996 Total Valuation: 281, 362 . 70
Town of Vail Adjusted Valuation: 281, 362 . 700
Fireplace Information: Restricted: Y qOf Gas AppLiances: #Of Gas Logs: 2 #Of Wood�Pallet:
**'t* *�**'k'A'* FEE S�MMARY **** ***�t****�tk***#*#****:tir
Building-----> 1,468.00 Restuarant Plan Review--> ,DO Total Calculated Fees---> 3,809.35
Plan Check---> 954.20 DRB Fee-----------------> 200.00 Additional Fees---------> .00
Investigation> .00 Recreation Fer---------> 684.15 Total Permit Fee--------> 3,809.35
Will Call----> 3.00 Clean—Up Deposit--------> 500.00 Payments----------------> 3,809.35
TOTAL fEES--------------> 3,809.35 BALANCE DUE------------> .00
'k*** * *:t****** *:t�k****
Item: 05100 BUILDING DEPARTMENT Dept: BUILDING Division:
06�20�1996 CHARLIE Action: NOTE PLANS TO DAN
07�10/1996 CHARLIE Action: APPR
Item: 0540a PLANNING DEPARTMENT Dept : PLANNING Division:
06�20�1996 CHARLIE Action: NOTE PLANS TO GEORGE
07�10/1996 GEORGE Action: APPR
Item: 05600 FIRE DEPARTMENT Dept: FIRE Division :
06/20/1996 CHARLIE Action: APPR N�A
Item: 05500 PUBLIC W�RKS Dept: PUB WORK Division:
06�20�1996 CHARLIE Action: NOTE PLANS TO LARRY P
07�17�1996 LARRY P Action: APPR LARRY PARDEE
Item: 05550 ENGINEERING Dept : ENGINEER Division:
06�20�1996 CHARLIE Action: NOTE PLANS TO TERRI
07�17�1996 TERRI M Action: APPR NEW SITE PLAN BY GREG H
**�** **�*** *�:t*�z********�r�***********�,�-��-�r:�**:�� �*:�:�
See Page 2 of this Document for any conditions that may apply to this permit .
DECLARATIONS
I hereby ackpowledge that I have read this appLication, filled out in full the information required, rompleted an accurate plot
plan, and state that all the information provided as required is correct. I agree to comply uith the informatian and plot plan,
to comply uith all Town ordinances and state laws, and to build this structure according to the Town's zoning and subdivision
codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTIONS SHALL BE MADE TWENTY-FGUR HOURS IN ADVANCE BY TELEPHOryE 9-2138 OR AT 0 � CE F OM .00 AM :00 PM
r
Send Clean-Up Deposit To: ROBERT STERIO SIGNATURE OF OWNER OR C01 ACTOR FO I SELF AID WNER
Ca���'�� G.�������/�
PAGE 2
*****************************�r**************************************************
CONDITI�NS OF APPROVAL
Permit # : B96-0164 as of 07�18�96 Status : ISSUED
***********************************************************�*******************�
Permit Type: NEW ( SFR,P�S,DUP) PERMIT Applied: 06�20�1996
Applicant: CARPENTRY UNL:CMITED, INC Issued: 07�18�1996
Job Address : 2763 KINNICKINNICK RD
Location: 2763�2765 KINICKINICK RD
Parcel No: 2103-143-03-001
********************************************************************************
CONDITIONS
*****************************�t*************************************,r************
1 . THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH
SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR
A FRAME INSPECTION.
2 . ATTIC SPACES SHALL HAVE A CEILING HEIGHT OF 5 FEET OR LESS,
AS MEASURED FROM THE TOP SIDE OF THE STRUCTURAL MEMBERS OF
THE FLOOR TO THE UNDERSIDE OF THE STRUCTURAL MEMEBERS OF THE
ROOF DIRECTLY ABOVE .
3 . NO MECHANICAL, ELECTRTCAL, OR PLUMBING WORK ALLOWED UNTIL
PERMITS HAVE BEEN AQUIRED
4 . Public Works sign off: required per DRB condition of approval
5 . CONTRACTOR NEEDS TO COMPLY WITH SITE PLAN REVISED BY GREG HA
LL. CHECK ELEVATIONS AT FRAMING TO DETERMINE ANY PROBLEMS WI
TH DRIVEWAY GR.ADE
� **Cf�ntact Eagle County Assessors Office �2J
� at 970-328-8640 for Parcel /�. TOWN OF VAIL CONSTRUCTION PERI�IIT ��
► <.Pt�x::�:L �i:�1D3-�y�-03- oo I _ PERMiT APPLICATiON FORM
/ ' . ' DATE: .J�.N�1 a g�
APPLICATION MUST BE FILLED OUT COMPLETELY OR IT MAY NOT BE ACCEPTED
******************�******�*** PERMIT INFORMATION *�*,t**:*********************
(�Building [�/)-pl�ing [ ,�Electrical [��•M�ch�iical �° [ ]-Other
Job Name: S'r�Rro�B RA�4�y �v f1( � �,"�" , � �
— � Job Add�e�s� , ,;�,�33 �' /��NN/CK/iVIV/C/L �
� �c"f 3
Legal Description: Lot / BZock � Filing UBnrvi Iorr• /NTERhG�iV�/�/
Owners Name: Ro.C3T STE'�e/c� .f.� - r�s�Y-oµor TEtip-
���-�BQ�.()LT Address: �EE �-�3o�`c Ph.D�sco�Ecr
`�'�'��e�t• --K•1�M. C N.Su�cT�NG Address: �3ox f�S72- �f1�c. �/ �S� Ph. 94�9-939/
General Description: 2 STOR�y ,DUPL�x
� Work Class: [✓]-New [ )-Alteration t
[ 7-Additional [ ]-Repair [ �-other
Number of Dwelling Units: 1 ,�VALC x Number of Accommodation Units: 2
N mber and Type ' of Fireplac�s: Gas Appliances Gas Lo s 2
���'� ����- �ti,��-�� g Wood/P�17.et —
***�;**** *****� * ************** VALUATIONS *************************,�+t**,t**,r
_ �`I��-c.��,.�`
�3,S�o.00 ���T
BUILDING: ; //8 �-tr° ����µ'���CTRICAL: S 6750 •p�
PLUMBING: � �p 5pp . �E¢v"'� OTHER: � �
�dECHANICAL: � $2 pc�, � ���,,.�- TOTAL: �i.�p, �25• P�
e2i OC]CJ. C�o ��-�j(C `� ����� � �o�5l ao. c�c ` ��
*t*********�**�,�**********,r CONTRACTOR INFORMAT'IbN **�r******8*��*�*,t�***,t,t****
eneral Contracto�: c�RprnlT,�y i��iGi„��Lp Town of Vail Reg. NO. l67- g
_ Addr.ess: L•�/ E, ME,qopw Dl��
Phone Number: ,.�76 _�� 9
Electrical Contractor: '�g ���
Address: !-- �- ___ Town of VaiS. Reg. NO.
Phone Nuynber: 4�q_,��9
Plumbing Contractor• .c-.+ �T`g'� �
Address: � ��"�F�6��'g ,__ .._-_ Town of Vail Reg. Np. /79 ,y
--- --� _ Phone Ni�a,ibez: ,52�.c 733�
Mechanical ContractAr. e _ � ccu,e,q ffE 7i�YG
Address: -7� A _ Town of Vail Reg. NO. /75��
- _ ���n�wmD 3PR/�llGS phnne Numbere _ 44�S-��f�,�-
****,�************•.��•:r:r�r+t,�,t�**�**,:, r°Uiz U�'F']:(:�: USE ��**,t******�*********,t*,tx,t*t,t,t*
BUILDING PEFtMIT FEE:
PLUMBING PERMIT FEE: —°--' BUILDING F?_,AN CHECK FEE:
MECHANICAL PERMIT FEE: PI'�MBIN�' P�N CHECK ,�'EE: `—
ELECTRICAL FEE: '-- ���IC� P� CHECK FEE:
OTHER TYPE OF FEE; - ��ATION FEE:
DRB FEE: C��-�P DEPOS IT: -- —
-��Ln�. TOTAL PERMIT FEES:
TYPE GROUP SQ.FT. VALUATION BUILDING:
SIGNATURE: --
ZONING:
Comments: SIGNATURE;
.
� in 4
CLEAN IIP DEP.OSIT REF[TND Tpw �PD�',�i2T sT��/O
2 7G.S �Y/iVivi�i`Yi/�liVic,� ,�,v -- �/��L - �''iGS7
. . . .
. ,
- ��i�
tQW� Df Val �'�
75 soulh tronfage road _
vail, colorada 81fi57
(303) 479-2138 or 479-2I39 office af eommunity development
TO: AI,L CONTRACTpgS CURREN�LYL REGISTERED WITH THg
TOWN OF VAIL
FROM: TO�WN OF VAIL PUBLIC WORKS/COMMUNITy DEVELOPMENT
DATE: MARCH 16, 1988
SU&TECT: C0�ISTRUCTION PARKING & MATERIAL STORAGE
In summary, Ordinance No. 6 states that it is unlawful for any
person to litter, track or deposit any soil, rock, sand, debris
or material, incliiding trash dumpsters, portable toilets and
workmen vehicles upon any street, sidewalk, alley or public
place or any portgon thereof. The right-of-way on all Town of
Vail streets and r�ads is approximately 5 ft. off pavement.
This ordinance will be strictly enforced by the Town of Vail
Public Works Department. Persons found viola.ting this ordinance
will be given a 24 hour written notice to remove said material.
In the event the person so notified does not comply with the
notice within the 24 hour time specified, the public Works
Department will remove said material at the expense of person
notified. The provisions of this ordinance shall not be
applicable to construction, maintenance or repair projects of .
any street or alle� or any uti.lities in the right-a-way.
To review Ordinance No. 6 in full, please stop by the Town of
Vail Building Depa�tment to obtain a copy, Thank you for your
cooperation on this matter.
Read and acknowledg by;
X
� ��E,�
osition/Relationship to Project (i.e. contractor, owner)
Z ° �
Date �
. '�!
tow� o uai _
75 soufh frontage rosd
vsll, colorado 81657
(ao3) 479-2138 or 479-2139 offlee of communiry derelopmen!
BUILDIN6 PERMIT ISSUANCE TIME FRAME
If thi_s permit requires a Town of Vail Fire Department Approval ,
Engineer'�s (.Public Works} review and approval , a Planning Department
review or Health Department review, and a review by the Building
Department, the estimated time for a total review may take as long
as three'weeks:.
All commerci�al (�large or small ) and all multi-family permits will
have to foTlow the above mentioned maximum requirements . Residential
and small projects should take a iesser amount of time. However, if
residential or smaller projects impact the various above mentioned
departments with regard to necessary review, these projects may
a7so take ttie three week period.
Every attempt will be made by this department to expedite this
permi�t as soon as possible.
I, the undersigned, understand the plan check procedure and time
frame..
,
- A9►'Ae to y. ,
S TE�/O 18��1� L Fj� .l�v,dGC-�
Pro,7ect Name
z� �
Date Wo Sheet was tur ed int� t e
Cormnunity Develnomp�t Department.
� MEMORANDUM
, , "
T�� � ALL CONTRACTORS
- FROM: TOWN OF VAlL PUBLIC WORKS DEPARTMENT
aATE: M�BY 9, 1994
RE: WHEN A "PUBLIC WAY PERMIT' IS RE�UIREO
Job Name: STE,P�of�P�p�y �vPLFX
Date: � � �
Pfease answer the foliowi g questionrtaire regarding ihe need for a "Pubiic Way Permit":
YES Np.
1) Is this a new residence? �
� - 2) is demotition work being pertormed `�
that requires the use of the right
of way, easemenis or public property?
3) Is any utifity worlc needed? �/
4) is the driveway be�ng repaved? `/
5) is different access nesded to siie ✓
other than existing driveway?
6) Is any drainage work being done �
affecting the righi of way, easements,
or public property? �
7) Is a "Revocable Right Of Way Permit" ✓
required?
8) A: Is the rigM �f way, easements or �
public property to be used for staging,
parking or fencing?
- B. If no to 8A, is a parking, staging �
or iencing plan required by Community
Development?
If you answered yes to any of these questions, a "Public Way Permit" must be obtained.
"Pub(ic Way Permit" applications may be obtained at the Public Work's office or at
Community Devefopment. If you have any questions please call Charlie Davis,the Town
oi Vail Construction Inspector, at 479-21�8.
I have read and answered all the above questions.
5 i�2ro T�,P,4� t�y .�vAL� �/�����
Job Na e Contractor's Signature Daie
' x
• � : f
� Town of Vail
25 South Frontage Road
Vail, Colorado 81657
� (303) 479-2138
Plan review based on
the 1991 iJniform Building Code
Project Number: PRJ96-0104 Name: STERIO/SRADLEY DUPLEX
Address: 2763 KINNICKSNNICK RD Date: June 25, 1996
Contractor: CARPENTRY UNLIMITED Occupancy: R3,M1
Type of Const: V N Engineer:KIMBERLY MCGHEE
Plans Examiner: DAN STANEK
# SHEET IDENTIFICATION CORRECTION REQUIRED
_____________________°________-----------------------
1 Party walls are required to be a 2hr fire
assembly.
2 Exterior surfaces with stucco shall be provided with
exterior metal lath as per UBC 47D6 with 2 layers of
paper. Windows and doors are required to be
adequately flashed(not with just screed metal) . A
lath inspection is required prior stucco
application.
3 A bathroom is required to have an openable window or
a mechanical ventilation system. - - Sec. 1205. (c)
4 In bathrooms with a tub or shower and in laundry
rooms a mechanical ventilation system connected
directly to the outside shall be provided. Bathrms
which contain only a water closet or lav. may be
ventilated with a recirculating fan. UBC 1205 (c) .
5 Domestic clothes dryer exhaust ducts shall be
installed as per UMC 1104 and 1903 . Flexible duct
connectors may not exceed 6 ' in length and shall not
be concealed within construction. Ducts shall
termi.nate outside the building and not exceed 14 '
length.
6 Craw7. spaces are required to be ventilated by
mechanical means or by openings. Such openings
shall have a net area of not less than 1 sq. ft. for
each 150 sq. ft. of under-floor area. UBC 2516 (c) 6.
7 Provi_de a minimum 18X24" underfloor access. UBC
2516 (c) 2 .
8 Furnaces not listed for closet or alcove
installation shall be installed in a room or space
having a volume at least 12 times the volume of the
furnace. A boiler unit will require a space 16
ti_mes larger than the boiler. UMC 504 (b)
9 Supply a mechanical drawinq indicating design of
system, size (BTU and volume) of equipment, vent
locaL-ion and termination, and combustion air to be
supplied prior to any installation.
�i�a r•- is;.�.d^,
��°���� ��P�
.
•
1G The qarage must be separated from the dwellinq by
lhr fire-resistive construction on the garaqe side.
- - Table 5-B & 503 . (d) exc.#3
11 The door between the garage and the dwelling is
rec�ui.red to be a 1 3/8 inch thick solid core or 20
minute self closing door. - - Sec. 503 . (d) exc.#3
12 The maximum rise of a step is 8 inches and the
minimum run is 9 inches. - - Sec. 3306. (c) exc #1
13 A handrail is required along a stairway. It is
required to be 34 to 38 inches above the nosing of
the steps and if the side is open, the maximum size
of an opening in the railing at the stairway is 4
inches. - - Sec. 3306. (i) & 1712.
14 A 36 inch high guardrail with a maximum opening of 4
inches is requied where step is greater than 30
inches to floor or grade below. - - Sec. 1712 .
15 The enclosed usable space under the stairs is
required to be protected by lhr fire-resistive
construction. - - 3306. (1)
16 The open side of all decks, porches, stairs, etc.
which are more than 30" above grade shall be
protected with a quardrail. Openings can not exceed
4" . Within R-1 occ. and all R 3, height min. is
36" -outside R-1 occ. height min. is 42" . UBC 1711.
17 At eaves and valleys an adequate underlayment sha11
be provided to protect a structure from ice buildup
and water damage. Two layers of felt solid mopped
to sheathing and between layers or a commercial
water & ice shield may be used as per Table 32B1.
18 Because of this project's location, the foundation
is required to be dampproofed to prevent damage to
areas below finished grade. UBC 1707 (dl .
19 Include a copy of the soils report for the site to
be built on. Sec. 2905.
2D Provide truss details by the truss manufacturer's
engineer. (reg in this state)
21 Basements shall have at least one operable window or
door approved for emergency escape or rescue which
shall open directly outside as per sec 12D4 of the
1991 UBC.
Town of Vail
25 South Frontage Road
Vaii, Colorado 81657
(303) 479-2138
Plan analysis based on
the 1991 IIniform Building Code
Project Number: PRJ96-0104 Name: STERIO/BRADLEY DUPLEX A
Address: 2763 KINNICKINNICK RD Date: June 25, 1996
Contractor: CARPENTRY UNLIMITED Occupancy: R3,M1
Type of Const: V-N Engineer:KIMBERLY MCGHEE
Plans Examiner: DAN STANEK
NOTE:The code items listed in this report are not intended to be a complete
listing of all possible code requirements in the 1991 UBC. It is a guide to
selected sections of the code.
SEPARATION
DIRECTION BOUNDARY AREA INCREASE FIRE PROTECTION
NORTH Property line 78.0 Feet 78.0 Feet
EAST Building 1.0 Feet 0. 0 Feet
SOUTH Property line 26.0 Feet 26 . 0 Feet
WEST Property line 30. 0 Feet 30 . 0 Feet
NORTH EAST SOUTH WEST
OCC BRG NON-BRG OPNG BRG NON-BRG OPNG HRG NON-BRG OPNG BRG NON-BRG OPNG
WALL WALL PROT WALL WALL PROT WALL WALL PROT WALL WALL PROT
R3 Dhr Ohr Nane lhr* 1.hr* NOP Ohr Ohr Nane Ohr Ohr None
M1 Ohr Ohr None 1hr* 1hr* NOP Ohr Ohr None Ohr Ohr None
None - - No fire protection requirements for openings.
Prot - - Openings are to be protected with 3/4 hr fire assemblies.
50% of the area of the wall maximum. Sec.2203. (b) & Table 5-A
Maximum sinqle window size is 84 sq.ft with no dimension
greater than 12 feet. Sec. 4306. (h)
NOP - - Openings are noc permitted in this wall.
* - - These walls may be required to have a parapet wall 30 inches
above the roofing. The parapet wall is required to have the same
fire rating as the wa11. See section 1710. for details and exceptions.
FL NAME AREA MIN.LIGHT MIN.VENT NO.EXITS EGRESS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 Bedraom #1 2D8 20.80 10.40 1 Yes
2 Bath room #1 71 0. 00 3 .55 1 No
2 Powder room 25 0.00 1.50 1 No
2 Kitchen 111 11.10 5.55 1 No
2 Living room 2D9 20.90 10.45 1 No
2 Dining room 177 17.70 8.85 1 No
2 Halls. closets, etc. 190 0.00 0.00 1 No
TOTAL FOR FLOOR 991 1
1 Garage 320 0.00 �.DD 1 No
1 Bedroom #2 166 16.60 8.30 1 Yes
1 Bedroom #3 166 16 .6D 8.30 1 Yes
1 Bath room 41 0. 00 2. 05 1 No
1 Ha11s, closets, etc. 270 0.00 0 . 00 1 No
TOTAL FOR FLOOR 963 1
B Laundry room 66]. 0.00 33 .05 1 No
TOTAL FOR FLOOR 661 1 Yes
BUILDING TOTAL 1954 1
't el�'=� V�i�t
� �° d�" ����
��� 4 ���r:�
FOOTNOTES:
1) EGRESS - An operable window or door that opens directly to the exterior
is required from this room. The minimum clear openable area must meet
� the f.ollowing. Sec. 1204.
11 The minimum clear height is 24 inches
2) The minimum clear width is 20 inches
3) The minimum clear area is 5.7 square feet
4) The maximum sill height is 44 inches
2) The number of exits is based on Table 33-A (Dwellings)
31 A mechanical ventilation system may be used in in lieu of exterior
openings for ventilation. - - Sec. 12Q5. (c)
4) The requirement for an egress window in the basement is based on
Sec. 1204.
ROOM DIMENSIONS:
Habikable space shall have a ceiling heiqht of not less than 7 feet 6
inches. Kitchens, halls, bathrooms and toilet compartments may have a
ceilinq heiqht of 7 feet measured to the lowest projection. If the ceiling
is sloping, then the minimum height is required in only 1/2 of the area.
- -Sec. 1207, (a)
Every dwelling unit shall have at least one room which has not less than 120
square feet of floor area. Other habitable rooms except kitchens shall have
an area of not less than 70 square feet. Sec. 1207. (b)
Habitable rooms other than a kitchen shall not be less than 7 feet in any
dimension. - - Sec. 1207. (c)
GLAZING REQUIREMFNTS:
All qlazing in hazardous locations is required to be of safety
glazing material. - - Sec. 5406. (d)
1) Glazing in inqress and egress doors except jalousies.
2) Glazing in fixed and sliding panels of sliding door assemblies and
panels in swinging doors other than wardrobe doors.
3) Glazing in storm doors.
4) Glazing in all unframed swinging doors.
5) Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam
rooms, bathtubs and showers. Glazing in any portion of a building wall
enclosing these compartments where the bottom exposed edge of the
glazinq is less than 60 inches above a standinq surface and drain inlet.
6) Glazing in fixed or operable panels adjacent to a door where the nearest
exposed edge of the glazxing is within a 24-inch arc of either_ vertical
edge of the door in a closed position and where the bottom exposed edge
of the qlazing is less than 6Q inches above the walking surface.
7) Glazing in an individual fixed or operable panel, other than those
locations described in items 5 and 6 above, than meets all of the
following conditions:
A. Exposed area of an individual pane greater than 9 square feet.
B. Exposed bottom edqe :1ess than 18 inches above th.e floor.
C. Exposed top edqe greater than 36 inches above the floor.
D. One or more walking surfaces within 36 inches horizontally of the
plane of the glazing.
8) Glazing in railings regardless of height above a walking surface.
Included are structural baluster panels and nonstructural in-fill
panels.
SMOKE DETECTOR REQUIREMENTS:
A smoke detector is required on the ceiling or wall at a point centrally
located in the corridor or area giving access to each sleeping area.
- - Sec. 1210. (a) 4.
A smoke detector is required on the ceilinq or wall in each sleeping
area. - - Sec. 1210. (a) 4.
A smoke detector is required in the basement. - - Sec. 1210. (a) 4.
A smoke detector is required on al1 stories. - - Sec. 1210. (a) 4.
If the upper level contains sleeping room(s) , a smoke detector is required
in the ceiling of the upper level close to the stairway.
- - Sec. 1210. (a) 4
Smoke detectors are required to be wired to the buildinq's power source and
shall be equipped with a battery backup. - - Sec. 1210 . (a) 3.
Detectors shall sound an alarm audible in all sleeping area of the dwelling
in which they are located. - Sec. 1210. (a) 4.
OCCUPANCY SEPARATION:
Between the qarage and the residence, materials approved for 1hr fire
construction are required on the garage side only and any doors between
the garage and the residence are to be a self-closing 1 3/8 inch solid
core door or a 20 minute fire door. Table 5-B & Sec. 503 . (d) exc. #3
STAIR REQUIREMENTS:
A stairway in a dwellinq must be at least 36 inches wide. - - Sec, 3306. (b)
The maximum rise of a step is 8 inches and the minimum run is 9 inches.
Sec. 3306. (c) exc. #1
Provide a handrail on one side a stairway 34 to 39 inches above the nosing if
there is 4 or more risers. - - Sec. 3306. ii)
Provide a guard rail where drop off is greater than 30 inches, Minimum height
= 36 inches, maximum opening size = 4 inches. - - Sec. 1712 . (a) exc. #1
The minimum headroom is 6 ft. 8 inches. - - Sec. 3306. (0)
Enclosed usable space under the stairs is required to be protected as required
for lhr fire-resistive construction. - - Sec. 3306. (1)
SHAFT ENCLOSURES:
1) Chutes and dumbwaiter shafts with a cross-sectional area of not more than
9 square feet may lined on L-he inside with not less than 26 gage
galvanized sheet metal with all joints locklapped. The outside must be
1 hr construction. All openings into any such enclosure shall be protected
by not less than a self-closing solid wood door 1 3/S inches thick or
equivalent. - - Sec. 1706 . (f)
2) Gas vents and noncombustible piping installed in walls passing through
3 fl.00rs or less do not need to be in 1 hour shafts.
- - Sec. 1706. (c)
3) Shafts for gas vents, factory built chimneys, piping, or ducts that do
not extend through not more than 2 floors need not be in 1 hour shafts.
- - Sec. 1706. (c)
4) All other shafts are required to be enclosed in a 1 hour assembly.
- - Sec. 1706. (a)
4 � � I � •
CRAWLSPACE REQUIREMENTS;
1) Provide ventilation either by mechanical means or by openinqs in exterior
walls. Opening shall provide a net area of not less than 1 square foot for
' each 150 square feet of area in crawl space. Openings shall be distributed
on two opposite sides and be located as close to corners as practical.
- - Sec. 2516. (c) 6. Note; Vent openings may be reduced to 10% of the above
if ground surface area is covered with an approved vapor barrier and the
building official a.pproves.
For a 308. Q sq.ft. crawlspace area:
Ratio Minimum sq.ft. of vent
1/150 2. 05
2) Provide 18 inch by 2.4-inch access openinq to the crawl space area. Note:
opening may be required to be larger if inechanical equipment is located
in the crawl space. - - Sec, 2516. (c) ?, .
3) Unless the wood is listed as an approved wood of natural resistance to
decay or treated wood, the minimum clearance between exposed earth and
floor joist is 18 inches. The minimum clearance to beams and girders is
is 12 inches. - - Sec. 2516. (c) 2.
ADDITIONAL REQUIREMENTS:
For R3 occupancy
This project will require a site improvement survey. Such survey
shall be submitted and approved prior to request for frame
inspection.
All crawl spaces within the Town Of Vail are limited to a earth to
structural floor ceiling height of 5 ' , be earth floor only, be
ventilated as per UBC 2516 (C) 6 with minimum access as per UBC
2516 (C12 and maximum access of 9 sq. ft.
Any bui.lding site with a slope of 30 degrees or more shall require an
engineer design. Such design shall address drainage, soil retainage
and structural design.
Excavation below slabs on qrade shall not be permitted without prior
approval.
Address numbers shall be posted plainly visible and legible from the
street.
For M1 occupancy
Slope garaqe floor to allow for drainage to outside to provide a
floor drain with �and and oil interceptor to dry well or to sewer.
Any garage floor drain connected to sewer must be approved by Upper
Eagle Valley Water & Sanitation District.
In garages with living area above, the walls of the garage wiich are
bearing the area above shall be protected with one hour fire
resistive construction. UBC 503 (B) .
. � ' . '
Town of Vail
25 South Frontage Road
Vail, Colorado 81657
(3D3) 479-2i38
Plan analysis based on
the 1991 Uniform Buildinq Code
Project Number: PRJ96-0104 Name: STERIO/BRADLEY DUPLEX B
Address: 2763 KINNICKINNICK RD Date: June 25, 1996
Contractor: CARPENTRY IINLIMITED Occupancy: R3 ,M1
Type of. Const: V-N Engineer:KIMBERLY MCGHEE
Plans Examiner; DAN STANEK
SEPARATION
DIRECTION BOUNDARY AREA INCREASE FIRE PROTECTION
NORTH Property line 82 . 0 Feet 82 . 0 Feet
EAST Property line 30. 0 Feet 30. D Feet
SOUTH Property line 21.0 Feet 21. 0 Feet
WEST Buildinq 0.0 Feet 0. 0 Feet
EXTERIOR WALL FIRE RATINGS AND OPENING PROTECTION
Table 17-A & Table 5-A
NORTH EAST SOUTH WEST
OCC BRG NON-BRG OPNG BRG NON-BRG OPNG BRG NON-BRG OPNG BRG NON-BRG OPNG
WALL WALL PROT WALL WALL PROT WALL WALL PROT WALL WALL PROT
R3 Ohr Ohr None Ohr Ohr None Ohr Ohr None lhr* lhr* NOP
M1 Ohr Ohr None Ohr Ohr None Ohr Ohr None lhr* 1hr* NOP
None - - No fire protection requirements for openings.
Prot - - Openings a.re to be protected with 3/4 hr fire assemblies.
50� of the area of Y_he wall maximum. Sec.2203. (b) & Table 5-A
Maximum single window size is 84 sq.ft with no dimension
greater than 12 feet. - - Sec. 4306. (h)
NOP - Openings are not permitted in this wall.
* These walls may be required to have a parapet wall 3D inches
above the roofing. The parapet wall is required to have the same
fire rating as the wall. See section 1710. for details and exceptions.
FL NAME AREA MIN.LIGHT MIN.VENT N�.EXITS EGRESS
2 Bedroom #1 20H 2O.80 10.40 1 Yes
2 Bath room 71 0. 00 3 .55 1 No
2 Kitchen 100 10. 00 5.00 1 No
2 Living room 1$1 18. 10 9,05 1 No
2 Di_ning room 1.4!� 14.40 7.20 1 No
2 Halls, closets, etc. 258 0. 00 0.00 1 No
TOTAL FOR FLOOR 962 1
1 Garage 320 0 . 00 Q.D� 1 No
1 Bedr.00m #2 166 16.60 8.3D 1 Yes
1 Bedroom #3 166 16.60 8.3D 1 Yes
1 Bath room 41 0 . 00 2.05 1 No
1 Halls, closets, etc. -216 0. 00 0. 00 1 No
TOTAL FOR FLOOR 963 1
B Basement 66:1 0.00 33. 05 1 No
TOTAL FOR F?�OOR 661 1 Yes
BUTLDINC TOTAL 1925 1
�, � �� ,�..
i ��
� � � �
� �
» c +'� �.� �-
_. ,' .� .� �`���;,_. � �,
FOOTNOTES:
1) EGRESS - An operable window or door that opens directly to the exterior
is required from this room. The minimum clear openable area must meet
the following. - Sec. 1204.
1) The minimum clear heiqht is 24 inches
2) The minimum clear width is 20 inches
3) The minimum clear area is 5.7 square feet
4) The maximum sill height is 44 inches
2) The number of exits is based on Table 33-A (Dwellings)
3) A mechanical ventilation system may be used in in lieu of exterior
openings for ventilation. - Sec. 1205. (c)
4) The requirement for an egress window in the basement is based on
Sec. 1204.
ROOM DIMENSIONS:
Habitable space shall have a ceiling height of not less than 7 feet 6
inches. Kitchens, halls, bathrooms and toilet compartmen.ts may have a
ceiling height of 7 feet measured to the lowest projection. If the ceiling
is slopinq, then the minimum height is required in only 1/2 of the area.
-Sec. 1207 . {aj
Every dwellinq unit shall have at least one room which has not less than 12D
square feet of floor area. Other habitable rooms except kitchens shall have
an area of not less than 70 square feet. - - Sec. 1207. (b)
Habitable rooms other than a kitchen shall not be less tha.n 7 feet in any
dimension. - - Sec. 1207. (c)
GLAZING RFQUIREMENTS:
All glazing in hazardous loc�tions is required to be of safety
glazing material . - - Sec. 5406 . (d?
1) Glazing in ingress and egress doors except jalousies.
2} Gla.zinq in fixed. and sli.ding panels of sliding door assemblies and
panels in swinging doors other than wardrobe doors.
3) Glazing in storm doors.
4) Glazing in all unframed swinging doors.
5) Glazing in doors and enc:losures for hot tubs, whirlpools, saunas, steam
rooms, bathtubs and showers. Glazing in any portion of a building wall
enclosing these compartments where the bottom exposed edqe of the
glazing is less than 60 inches above a standing surface and drain inlet.
6) Glazing in fixed or operable panels adjacent to a door where the nearest
exposed edge of the gla..xing is within a 24-inch arc of either vertical
edge of the door in a closed position and where the bottom exposed edge
of the glazing is less t=han 60 inches above the walking surface.
7) Glazing in an individual fixed or operable panel, other than those
locations described in items 5 and 6 above, than meet; all of the
following conditions:
A. Exposed area of an individual pane greater than 9 square feet.
B. Exposed bottom edge less than 18 inches above the floor.
C. Exposed top edge g�-eater than 36 inches above the floor.
D. One or more walki.ng surfaces within 36 inches hox�izontally of the
plane of the glazing.
8) Glazinq in railings regardless of height above a walki_ng surface.
Included are structural baluster panels and nonstructural in-fill
panels.
See exceptions.
SMOKE DETECTOR REQUIRF.MENTS:
A smoke detector is required on the cei.lin�� or wall at a point centrally
located in the corri.dor or area giving a��cess to each sleepinq area.
Sec. 1210. (a) 4.
A smoke detector is required on the ceili.mg or wall in each sleepinq
area, - - Sec, 1210. {a) 4.
A smoke detector is required in the basement. - - Sec. 1210. (a) 4.
A smoke detector is required on all stories. Sec. 1210. (a) 4.
T_£ the upper level contains sleeping room(s) , a smoke detector is required
in the ceiling of the upper level close to the stairway.
- - Sec. 1210. (a1 4
Smoke detector.s are required to be wired to the building's power source and
shall be equipped with a battery backup. - - Sec. 1210. (a) 3.
Detectors shall sound an alarm audible in 311 sleeping area of the dwelling
in which they are located. - - Sec. 1210. (a) 4.
OCCUPANCY SEPARATION:
Between the garage and the residence, materials approved for 1hr fire
construction are required on the garage sid� only and any doors between
the qarage and the residence are to be a self-closing 1 3/8 inch solid
core door or a 20 minute fire door. - - Table 5-B & Sec. 503. (d) exe. #3
STAIR REQUIREMENTS:
A stairway in a dwelling must be at least 36 inches wide. - - Sec. 3306. (b)
The maximum rise of a step is 8 inches and the minimum run is 9 inches.
- - Sec. 3306. {c) exc. #1
Provide a handrail on one side a stairway 34 to 38 inches above the nosinq if
there i_s 4 or more risers. - - Sec. 3306. (i)
Provide a guard rail where drop off is greater than 30 inches. Minimum height
= 36 inches, maximum opening size = 4 inches. - - Sec. 1712. (a) exc. #1
The minimum headroom is 6 ft. - 8 inches. - - Sec. 3306 . (0)
Enclosed usable space under the stairs is required to be protected as required
for lhr fire resistive construction. - - Sec. 3346. (1}
SHAFT ENCLOSURES:
1� Chutes and dumbwaiter shafYs with a cross uectional area of not more than
9 square feet may lined on the inside with not less than 26 gaqe
galvanized sheet metal with all joints locklapped. The outside must be
1 hr construction. All openings into any such enclosure shall be protected
by not less than a sel.f-closing solid wood door 1 3/8 inches thick or
equivalent. - - Sec, 1706. (f)
2) Gas vents and noncombustible piping installed in walls passing through
3 floors or less do not need to be in 1 hour shafts.
- - Sec. 17D6. (c)
3) Shafts for qas vents, factory-built chimneys, piping, or ducts that do
not extend through not more than 2 floors need not be in 1 hour shafts.
- - Sec. 1706. (c)
4) All other shafts are required to be enclosed in a 1 hour assembly.
- - Sec. 17D6. (a)
CRAWLSPACE REQUIREMENTS:
1) Provide ventilation either by mechanical means or by openings in exterior
walls. Opening shall provide a net area of not less than 1 square foot for
each 150 square feet of area in crawl s;gace. Openinqs shall be distributed
on two opposite sides and be located as close to corners as practical.
- Sec. 2516. (c) 6. Note: Vent openings may be reduced to 10� of the above
if ground surface area is covered with an approved vapor barrier and the
building official approves.
For a 308.0 sq.ft. crawlspace area:
Ratio Minimum sq.ft. of vent
1/150 2. 05
2) Provide 18-inch by 24 inch access opening to the crawl space area. Note:
opening may be required to be larger if inechanical equipment is located
in the crawl space. - Sec. 2516. (c) 2.
3) Unless the wood i.s listed as an approved wood of natural resistance to
decay or .treated wood, the minimum clearance between exposed earth and
floor joist is 18 inches. The minimum clearance to beama and girders is
is 12 inches. - - Sec. 2516. (c} 2 .
ADDITIONAL REQUIREMENTS:
For R3 occupancy
This project will require a site improvement survey. Such survey
shali be submitted and approved prior to request for frame
inspection.
All craw7_ spaces wi.thin the Town Of Vail are limited to a earth to
structural floor ceiling height of 5' , be earth floor only, be
ventilated as per U�C 2516 (C) 6 with minimum access as per UBC
2516 (C) 2 and maximum access of 9 sq. ft.
Any buildinq site with a slope of 30 deqrees or more shall require an
engineer design. Such design shall address drainage, soil. retainage
and structural design.
Excavation below slabs on grade shall not be permitted without prior
approval.
Address numbers shall be posted plainly visible and legible from the
street.
For M1 occupancy
Slope garage floor to allow for drainage to outside to pr.ovide a
floor drain with sand and oil interceptor to dry well or to sewer.
Any garage floor drain connected to sewer must be approved by Upper
Eagle Valley Water & Sanitation District ,
In garages with living area above, the walls of the garage wiich are
bearing the area above shall be protecte.d wi.th one hour fire
resistive construction. UBC 503 (B) .
� �
HEP�h'ORTH-PA�tiLAK CiEOZECH'�'ICAL� IIVC. s020 Rnad]5-3
Glemsood Springs,CO 51601
April 5, 1996 F�9�0 9�s-sas�
Phonc 9'0 9�5-i9SS
Doug Bradley
2771 Kinnickinnick Road, Unit 1
Vail, Colorado 81657 Job No. 196 169
Subject: Subsoil Study for Foundation Design, Proposed Duplex, Lot 1, Block 4,
Vail Intermountain Subdivision, Knuuckinnick Road, Vail, Colorado.
Dear Mr. Bradley:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study for
design of foundations at the subject site. The study was conducted in accordance with
our agreement for seotechnical engineering services to you dated March 27, 1995. The
data obtained and our recommendations based on the proposed construction and
subsurface conditions encountered are presented in this report.
Proposed Construction: The proposed duplex will be a two story wood frame
structure over a basement level located on the site as shown on Fig. 1. Attached
garages will be located near the front of the lot at existing grade. Basement and garage
floors will be slab-on-�rade. Cut depths are expected to range between about 4 to 6
feet. Foundation loadings for this type of construction are assumed to be relatively
light.
If building conditions or foundation loadings are sianificantly different from those
described above, we should be notified to reevaluate the recommendations presented in
this report.
Site Conditions: The site was vacant at the time of our field work and there was
about 1 'h feet of snow cover. Several piles of snow up to about 8 feet high were
iocated near tne tront or tiie property. 1 he site is gently rolling with a slight to
moderate slope down to the north. The rear por:ion of the lot is relatively flat.
Approximately 8 to 10 feet of elevation difference exists across the front half of the lot.
Vegetation on the site consists of grasses and weeds with scattered aspen and evergreen
uees along the perimeter. There appeared to be a low landscape berm along the
western property line.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits at the approximate locations shown on Fig. 1. The logs
of the pits are presented on Fig. 2. The subsoils encountered, below about 3 '/z to 4
feet of topsoil, consist of slightly ciayey silty sand and gravel with cobbles and
scattered boulders. Results of a gradation analysis performed on a sample of the sand
and gravel (minus �-inch fraction) obtained from the site are presented on Fig. 3. The
laboratory testing is summarized on Table I. No free water was observed in the pits at
the time of excavation and the soils were moist.
Doug Bradley
April 5, 1996
Paae 2
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 2,500 psf for support of the proposed duplex. Footings should be a
minimum width of 16 inches for continuous walls and 2 feet for columns. Topsoil,
loose and disturbed soiis encountered at the foundation bearing 1eve1 within the
excavation should be removed and the footing bearing level extended down to the
undisturbed natural soils. Exterior footings should be provided with adequate cover
above their bearing elevations for frost protection. Placement of footings at least 48
inches below the exterior grade is typically used in this area. Continuous foundation
walls should be reinforced top and bottom to span local anomalies such as by assuming
an unsupported length of at least 12 feet. Foundation walls acting as retaining
structures should be designed to resist a lateral earth pressure based on an equivalent
fluid unit weight of at least 45 pcf for the on-site granular soil as backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support
lightly loaded slab-on-grade construction. To reduce the effects of some differential
movement, floor slabs should be separated from all bearing walls and columns with
expansion joints which allow unrestrained vertical movement. Floor slab control joints
shouid be used to reduce damage due to shrinkaQe crackina. The requirements for joint
spacing and slab reinforcement should be established by the desiQner based on
experience and the intended slab use. A minimum 4-inch layer of free-draining gravel
should be placed beneath basement level slabs to facilitate draina�e. This material
should consist of minus 2-inch agQreQate with less than 50% passing the No. 4 sieve
and less than 2% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor densiry at a moisture content near optimum. Required fill
can consist of the on-site sand and gravel devoid of vegetation, topsoil and oversized
rock.
Underdrain System: Although free water was not encountered during our exploration,
it has been our experience in the area that local perched groundwater may develop
during tunes of heavy precipitation or seasonal runoff. Frozen ground durin� spring
runoff can create a perched condition. We recommend below grade construction, such
as retaining walls and basement areas, be protected from wetting and hydrostatic
pressure buildup by an underdrain system.
The drains should consist of drainpipe placed in the bottom of the wall bac�ll
surrounded above the invert level with free-draining granular material. The drain
H-P GEOTECH
Doug Bradley
April 5, 1996
Page 3
should be placed at each level of eacavation and at least 1 foot below lowest adjacent
finish grade and sloped at a minimum 1% to a suitable gravity outlet. Free-draining
granular material used in the underdrain system should contain less than 2% passing the
No. 200 sieve, less than 50% passin� the No. 4 sieve and have a maximum size of
2 inches. The drain gravel backfill shouid be at least 1 '/z feet deep.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the duplex has been completed:
1) Inundation of the foundation excavations and underslab areas should be avoided
during construction.
2) Exterior backf'ill should be adjusted to near optimum moisture and compacted to
at least 95% of the maximum standard Proctor density in pavement and slab
areas and to at least 90% of the maximum standard Proctor density in landscape
areas. Free-draining wa11 backfill should be capped with about 2 feet of the
on-site, finer graded soils to reduce surface water infiltration.
3) The ground surface surrounding the exterior of the buildin; should be sloped to
drain away from the foundation in all directions. We recommend a minimum
slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of
3 inches in the first 10 feet in pavement and walkway areas.
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
Limitations: This study has been conducted in accordance with generaliy accepted
geoteciuucal engineerin� principles and practices in this area at this time. We make no
other warranry either expressed or implied. The conclusions and recommendations
submitted in this report are based upon the data obtained from the exploratory pits
excavated at the locations indicated on Fig. 1, the proposed type of construction and
our experience in the area. Our fmdings include interpolation and extrapolation of the
subsurface conditions identified at the exploratory pits and variations in the subsurface
conditions may not become evident until excavation is performed. If conditions
encountered during construction appear different from those described in this report, we
should be notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and fieid services during
H-P GEOTECH
Doug Bradley
Apri15, 1996
Paje 4
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
cbanges may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
If you have any questions or if we may be of further assistance, please cali our office.
Sincerely,
HEPWORTH - PA�T�LAK GE C � INC.
�F,'�,��,,.. ....,G/y�j'v
�o�.ytiPr� �,aa�s F�.�:T
ro o •,
'o Z'
Jord Z. mson, Jr., ;� 2�7a7 �; '
9}'•., y s :'c��
Reviewed By: �`��,s, //96 ;G\r%'
S��NA� EN
� _
�
Daniel E. Hardin, P.E.
JZAIro
Attachments
cc: iiRM Consuitants - Attn: Kim McGhee
H-P GEOTECH
. APPROXIMATE SCALE
- I�� = 20�
LOT 2
--�_ — —
i PROPERTY ---- --___ �_
� BOUNDARIES
I
�
�
i
i � PIT 2
I ,
I '
�
�
�
� �I
i PROPOSED BUILOING i �
LOT 3 � '
�
�
I I
i
i i
, ■ PIT I
' LOT I
�
I '�
� I
�
i
� �
4
�
,
;
�
�_ _�_ � ;
__ i
KINNIC!(INNICF( ROqD
196 169 HEPWORTH-PAWLAK LOCATION OF EXPLORATORY PITS F�9• I
GEOTECHNICAL, Inc.
- PIT 1 PIT 2
p 0
wc=za.a
Y Y
DD=69 N
iy ��' • `L
' 5
5 ''°° '
, °.,, s
� �°�T ,-
Y a. WC=9.4 ��': N
� ��: < DD=125 ;14. —i WC=6.9 �
� ��" -- 'L' --� +4=46
=C __i WC=72.9 .'G —200=14
—2D0=23
LL=23
PI=7
�� 10
LEGEND:
� TOPSOIL, sandy silt,slightly gravelly, scattered cobbles, stiff, moist, black, organic.
�.'� SAND AND GRAVEL (5M-GM); sii#y,slighfij clayey wi#h cobbles and scattered boutders,
b medium dense to dense, moist, light brawn.
�.9 Hand driven liner sample.
' Disturbed bulk sample.
--'
NOTES:
1. Exploratory pits were excavated on March�3,i 996 with a backhoe.
2. Locations of exploratory pits were measured approximately by pacing from features shown on
the site plan provided.
3. Elevations of exploratory pits were not measured and logs of exploratory pits are drawn to depth.
4.The expioratory pit locations should be considered accurate only to the degree
implied by the method used.
5.The lines between materials shown on the exploratory pit logs represent the approximate
boundaries between material types and transitions may be gradual,
6. No free water was encountered in the pits at the time of excavation.
Fluctuations in water Ievel may occur with time.
7. Laboratory Testing Results:
WC = Water Content(%) -200 = Percent passing No. 200 sieve.
DD = Dry Density tpcf) LL= Liquid Limit{°/a)
+4 = Percent retained on No. 4 sieve. PI = Plasticity Index(%)
196 169 HEPWORTH - PAWLAK LOGS OF EXPLORATORY PITS Fig. 2
GEOTECHNICAL, INC.
KfUflOM�fl AFIALYSIS �����
NAE AEADI4G5 US.StAN'.Y.RD SERIES QEAP SOUAPE OPf7+liNGS
24 HR. 7 HP
WMIN. 15MIN. �MIN.19M7N. 6MM, iMIN. �XI� #100 R50 /30 fIB f8 Ab 3QifY 3N' 17(C 3' 46' 0
7�
� 10
� p
70
�
�
� 0
� w
Z Z
N '
Q
N W
� � �
� � �
Z �
U V
K �
a , � a
�
� �
m
�
io
w
0 70°
.001 A02 A06 A09 .018 .651 117b .160 .300 .800 1.18 236 d76 9.W 79.D 37.6 7B2 16Y 203
125 'T�
DIAMEfER OF PARTICLES IN MIWMEfERS
54HD Gft4YEL W9v�Fc
C.A1'TQSU.T ry MfDIUM E
GRAVEL 46 % SAND 40 % SILTANDCLAY 14 %
LIDUID LIMIT % PLASTICIN INDEX %
s,onaP�oF: Silty Sand and Gravel with Cobbles FROM: Pit 2 at fr7 Feet
196169 HEPWORTH - PAWLAK GRADATION TEST RESULTS Fig. 3
GEOTECHNICAL, INC.
. �
� c �
m
� � +� m
— — — �
W � in � c!� � in C7
C� c � ? > ?� > ? -o
� N (0 N N a = C N
� v�i � f6 (�` f0 (7 � O (6 N
N
� m U � Ua N �- � �
� � � � � � � mo
� cn U
z t 'D L "O c0 �„ ],L
p� C � C OJ �p ±+ �+
°' in ci� cn cn O U c�i �
0
�
w
o , _
r
'� w z �
V UJ o a e a
Z � 2 o h ,"
J � o
J �
a w
(„� � F x
Z � Q o � r
� Z —
2 �/i � `
J
V w �
w �- �
L c
w
O oc ~ � € — `''
W — Q a � � � N
� � a
Y m �
a
a �' m w = � > ro d�
� .! ¢ �' O in N r
\� 6 6 Z
Q J
d U-
� �
� � C � �'
� � O y
O Q F-
� � O
� a
a W
W � � � �
_ (� c�
J 1^
H � YI
VI U
Q � W � T �
z o
w
s � w '� � � �
� y r � �:
a o o � � N N �
2 � U �
N
�
� N r
p w °a (fl r r i
Q � � (�f �
O r
W
Y
�
va+ a � N
—
� a„►� Crestline-
` 1� Windows8,Doors ROUGH OP�NIN� G� ID�
- - CrestWoodTM Casement
i� �
1�WIDE CASEMENT
Uni1 Dimension 1'-5 42' 1'-7 Vp" 1'�N VZ" 2'-5�/z' 2'-11 Vz"
Rough Opening 1'fi" 1'-8" 2'-a" 2'-6" 3'-0"
MetriCR.O,�mm) 457 SOB G70 7G2 914
GWs95'ae 12�/p" 14�/p" 18�Ip" 24�!p" 30�/2'
�,_����Z,..
610 � � � w� � . .. ... . . .
18'�2° PICTURES
wcn i-is2o i•ts2o i-zozo �-zszo i-3o2o
l -- f—.
2 ����2� ,�7 .�JJ (�� 1��� ��I� Me11ycF0�lmm 2 914,2N 330s7 3421�9z 415242� 5602�3Z.
3'•0" � _
30 t/2• I_�
WCA 1-0630 7-1830 1-2030 7-2630 1-3030 GlasaSize 30�/Z" 36 Vz" 42 Vz` 54 Vi" 66 Vp"
_
31067� . � �1 �' �� .��'i � � 36067 �� � �=U L_WJ�'� ��
3r�„
36 /"
2 - - 3036 1-3636 1-4036 1-5036 1-6036
WCa 1-1636 14836 1-2036 1-2636 1 3036 WCr 1 �
. I ___. -__ ���0 311�/z" I t � ��I �I_I �I
3qp Za„. �I � � a � O''���� " ' 422ta9„ �� � � � _._�
z
WCA -� 1-7640 1-1640 1-2040 1-2640 � t-3040 �D� '� � WCP 1•3040 1-3640 1-4040 1-5040� 1-6040
41372ZN a W�I I�� � ���.. I + 49!¢" ��� �� ����. �I I! �,LLIJ �
4,8� 4._e„ _
48�/q"
WCA 1-1646 1•1646 1-2046 1-2646 1-3046 WCP 1-3046 73646 1-4046 1•5046 1-6046
__ - -_ -
� � �
� 4'11 /p"��.
, � �.4 55242y�� � � � ���I I-__ . 1524 .. �� � �I Ir _ ��' __
54 V2,
�,�. WCn 7-1650 1-1850 1-2050 1-2650 1-3050 wCr 1-3050 7-3650 1-4050 1-5050 7-6050
.. . .- � . ._...__- �
. 5'-5 42°� � 5 5'/2,�. .. '-� I�I � � �I�
� 56�6„ � � � � � !� � 5 VN �. _ . _. .__.__
16�6 i,
` 60 /Z � - �G x . _
WCA 1-7656 1-1856 1-2056 1-2656 1-3056 WCP 1•3056 7-3656 1-4056 1-5056 1-6056
.—. i I ...___ - � --_
5'-11 �l y" _� '�� 5,-71 �/�° - _ _ ���--�{I �
6 0 '� _ �' .�._ 1829 __ �I ��� I I I I I I�I
1829 � ���_ �
��l ���
;: � � __�
66�,2• �_ ._� .___ 66�,2� .--. ___ - .___ __ .
WCA 1•1660 7-1860 7-2060 7-2660 WCp i-3060 7-3660 1-4D60 1-5060 1-6060
, 2-WIDE �� 3-WIDE WCP3 TRIPLE RICTURE �❑�
Rough Soft Met- Rough Soft Met- � Solt Metric
� Glass Opg. U.D. ric Fough Opg. U.O. ric Rough Side Glass Picture Glass Rough Unit Rough Open-
Size Width Width Opening Width Width Opening Size Size Opening Dimension ing(mm)
12 V2" 3'-0" 2'-71 4p,. 914 4,-6„ 4,5 Vp„ 1372 12 Yz% 361/p" 6'.6" 6'-5�/p" 1961
14 Vp" 3'-4" 3'-3 Vz" 1016 5'0„ 4'-11 t/p„ 1524 72�i2" M12 V2" 7'-0" 6'-11�/z' 2134
18 VZ" 4'-0„ 3'41 t/p" 1219 6'0" 5-11 1/2„ �829 12�/p" Gh�/p" 8'-0" T-11�/p" 2438
24 Vz" 5'-0" 4'-11�/p" 1524 7'-6" 7'-5 VZ" 2286 12 1/2" 661/p" g•.p" g'-11�/p" 2743
30 VZ 6,0" 5'-11�/p„ 1829 9.-0.. 8'-11 1/z" 2743 18 V2" 36 Y2• 7'_6" 7'-5 �g" 2286
� 18 '/z 42�/2" e'-0" 7�11�/p" 2438
4�WIDE ,," �; ' S•WIDE ; ; ,e �,z, 54,,2� 9_a„ a.,, ��Z- z�43
� ..'_ ' '--.. - 10 �/z" 66�/p` 10'-0" 9'-11�/y" 3048
12 4p" 6,0., 5, 11 �l1,. 1ffi9 � 7'-B" 7'-5�/z" 22F76 24�/p" 36 Yp" B'•6" 0'-5�ip" 259i
�� 141�2„ 6,$�, 8,7�/p' 2032 6._Q,� �,_3 1�2�. 2540 pq f�2� q21�2, g,_0„ 0�_�1 i/L" 2743
� 18�/p` 8'-0„ T-11 Vp" 2438 10.•0„ 9'41 t/p,. 3�48 26�/z` G6 Vp" 11'A" 10'-11 �/2" 3353
24�/p" 10,0" 9'-11�/2" 3048 12,6„ 1Y-5�/2" 3810
30 Vp" 72.0„ 11,d1 V2" 3658 NA NA NA
KRM CONSULTANTS, INC. 19701 949-9397
P.O. BOX 4572 FAX 949-1577
VAIL, COLORADO 81658
FIELD REPORT
T0: DATE:
�0� a�a
GAtzt'ENTCZ`� UNLIMITEb ARRNE: 8;00 A• M�
�.4X 47(0 - 3097 DEPART: 8 : 3o q. i•�1 .
WEATHER:
c.o�� , st.�ow� t`ty
ATTENTION:
bohl �2ESS�EY
PROJECT: JOB NUMBER:
STE�Ib – B2e�DLE`f DUPLEX � (n0 `f'– II
This was a final framing review for this project. Our previous site visit, on 10/29/96, revealed some
items that required correction. With the exception of the exterior deck framing, these items have been
completed to our satisfaction, and no other problems have been discovered. The exterior deck framing
was not done according to the structural drawings, and some remedial work is required. Please see
the attached sketch.
.,
� `,�n1Nt111liillirrrluijy�
.��`�p�`P90 RE�ISTSt��, �. �`_
`�a�;��,Y R. �'4�9 =
��'t 0k, ',kc�"° :
` ,� , k �1 rni =
� °Y;+,P�`-��99 �'� _
.
�� . ��,
�: •�,�`
Jl?�FFSS�O N AL ENG�\�
��'"�JdblJi��lAltWA1+,��� .
SIGNED: /� COPY T0:
Toult�i n� V�.I L — C�}(�c� �ELbMAN
REVIEWED:
i
AIR MAINTENANCE CO. , INC. PROJECT: STERIO/BRADLEY DUPLEX
p..0. BOX 2107 CLIENT: ACCURATE HEATING
GLENWOOD SPRINGS, CO 81602 DATE: AUGUST O1, 1996
RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: RAYMOND PAYNE
CLIENT INFORMATION:
NAME: ACCURATE HEATING
ADDRESS: 3441 S. GRAND AVENUE
CITY, STATE: GLENWDOD SPRINGS, COLORADO
TOTAL BUILDING LOADS :
------------------------------------------------------------------------------
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
------------------------------------------------------------------------------
3-D WINDOW DBL PN LOW EMIT WOOD FR 129 4, 285 0 3, 630 3, 630
8-P GLS DOOR DBL LOW E WOOD FR 84 2 , 790 0 1,596 1, 596
9-G FRENCH DODR DBL CLR GLS WOOD FR 21 1, 009 0 798 798
12-H WALL R-19 + 1/2" GYP BRD(R-0.5) 1, 178 6, 502 0 1, 668 1, 668
15-H WALL >5�BELOW GRD 8" BLK+R-19 586 1, 672 0 0 0
10-D DOOR WOOD SOLID CORE 25 1, 058 0 271 271
16-H CEILING R-38 INSULATION 912 2, 182 0 854 854
21-A BASEMT FLOOR 2 'OR> BELOW GRADE 636 1, 404 0 0 0
------------------------------------------------------------------------------
SUBTOTALS FOR STRUCTURE: 3 , 571 20, 902 0 8, 817 8,817
PEOPLE 0 0 0 0 0
APPLIANCES 0 0 0 0 0
DUCTWORK 0 0 0 0 0
INFILTRATION W.CFM: 144 . 5 S.CFM: 72 . 2 0 14 , 621 0 1, 589 1, 589
VENTILATION W.CFM: 0. 0 S .CFM: 0. 0 0 0 0 0 0
------------------------------------------------------------------------------
SENSIBLE GAIN TOTAL 10, 406
TEMP. SWING MULTIPLIER X 1. 00
BUILDING LOAD T�TALS 35, 523 0 10,406 10,406
------------------------------------------------------------------------------
SUPPLY CFM AT 20 DEG DT: 473 CFM PER SQUARE FOOT: 0.217
SQUARE FT. OF RO�M AREA: 2 , 184 SQUARE F��T PER TON: 2 , 518 . 547
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.523 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.867 TONS
CALCULATIONS ARE BASED ON 7TH EDITION �F ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS .
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
AIR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
STERIO/BRADLEY DUPLEX AUGUST O1, 1996 PAGE 2
************************ TOTAL ZONE LOADS FOR ZONE # 1 ***********************
------------------------------------------------------------------------------
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
------------------------------------------------------------------------------
3-D WINDOW DBL PN LOW EMIT WO�D FR 129 4, 285 0 3, 630 3, 630
8-P GLS DOOR DBL LOW E WOOD FR 84 2 , 790 0 1, 596 1, 596
9-G FRENCH DO�R DBL CLR GLS WOOD FR 21 1, 009 0 798 798
12-H WALL R-19 + 1/2" GYP BRD(R-0.5) 1, 178 6, 502 0 1, 668 1, 668
15-H WALL >5�BEIAW GRD 8" BLK+R-19 586 1, 672 0 0 0
10-D DOOR WOOD SOLID CORE 25 1, 058 0 271 271
16-H CEILING R-38 INSULATION 912 2 , 182 0 854 854
21-A BASEMT FLOOR 2 �OR> BELOW GRADE 636 1, 404 0 0 0
------------------------------------------------------------------------------
SUBTOTALS FOR STRUCTURE: 3,571 20, 902 0 8, 817 8, 817
PEOPLE 0 0 0 0 0
APPLIANCES 0 0 0 0 0
DUCTWORK 0 0 0 0 0
INFILTRATION W. CFM: 144.5 S.CFM: 72 .2 0 14 , 621 0 1, 589 1,589
VENTILATION W.CFM: 0. 0 S.CFM: 0. 0 0 0 0 0 0
------------------------------------------------------------------------------
SENSIBLE GAIN TOTAL 10, 406
TEMP. SWING MLTLTIPLIER ?C 1.00
BUILDING LOAD TOTALS 35, 523 0 10, 406 10, 406
------------------------------------------------------------------------------
SUPPLY CFM AT 20 DEG DT: 473 CFM PER SQUARE FOOT: 0. 217
SQUARE FT. OF ROOM AREA: 2, 184 SQUARE FOOT PER TON: 2 , 518. 547
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.523 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0. 867 T�NS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
AIR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
STERIO/BRADLEY DUPLEX AUGUST O1, 1996 PAGE 3
************************* MISCELLANEOUS PROJECT DATA *************************
DESIGN CONDITIONS: WINTER SUi✓�IER
OUTDOOR DRY BULB TEMPERATURE -20 DEG.F 95 DEG.F
INDOOR DRY BULB TEMPERATURE - ZONE 1 72 DEG.F 75 DEG.F
DESIGN TEMPERATURE DIFFERENCE - ZONE 1 92 DEG. F 20 DEG.F
INDOOR-OUTDOOR GRAINS DIFFERENCE 0 GRAINS
OUTDOOR DAILY TEMPERATURE RANGE MED
GENERAL PROJECT DATA:
PR�JECT DATA FILE NAME: C:\ELITE\STERIO
TOTAL GROSS WALL AREA (SF) : 2, 023 . 00
NON-GLASS DOOR AREA (SF) : 25. 00
TOTAL NET GLASS AREA (SF) : 234 . 00
TOTAL SKYLIGHT AREA (SF) : 0. 00
TOTAL NET WALL AREA (SF) : 1, 764 . 00
TOTAL NET ROOF AREA (SF) : 912 . 00
TOTAL EXPOSED AREA (SF) : 2, 935. 00
PEOPLE LATENT LOAD MIJLTIPLIER: 230. 00
PEOPLE SENSIBLE LOAD MULTIPLIER: 300. 00
LATITUDE DEGREES: 39 . 00
TEMPERATURE SWING MULTIPLIER: 1. 00
EXTERNAL SHADING TYPES:
NO. OVERIiANG OFFSET
---- -------- ------
1• 7 . 0 0. 0
2 . 0. 0 0. 0
3 . 0. 0 0. 0
4 . 0. 0 0. 0
5. 0. 0 0. 0
6• 0. 0 0. 0
7. 0. 0 0. 0
OUTSIDE AIR DATA: WINTER SUMMER
INFILTRATION AIR CHANGES PER HOUR: 0. 400 0 .200
CUBIC FEET OF CONDITIONED SPACE: X 21, 672 X 21, 672
-------- --------
8, 669 4, 334
X 0. 0167 X 0. 0167
-------- --------
TOTAL BUILDING INFILTRATION CFM: 144 .5 72.2
TOTAL BUILDING VENTILATION CFM: 0. 0 0. 0
INFIL. & VENT. SEN. GAIN MULTIPLIER: 22 . 00 = (1. 10 X 20 SUMMER TEMP. DIFF. )
INFIL. & VENT. LAT. GAIN MULTIPLIER: 0.00 = (0. 68 X 0 GRAINS DIFFERENCE}
INFIL. & VENT. SEN. LOSS MULTIPLIER: 101.20 = (1. 10 X 92 WINTER TEMP. DIFF. )
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
AzR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
STERIO/BRADLEY DUPLEX AUGUST O1, 1996 PAGE 4
*�***********�******�*****�* DETAILED ROOM LOADS ***�*********************���*
ITEM AREA -U- HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
1. BASEMENT 24 . 0 WID X 23 . 0 LEN = 552 SF CEIL.AT = 10. 0
W -WALL-15H 9 X 23 199 0. 031 2 . 9 568 0. 0 0 0
N -WALL-15H 9 X 24 216 0. 031 2 . 9 616 0. 0 0 0
W -GLAS-3D 2-P O-0 S-1 0%S 8 0. 361 33 . 2 266 64 . 0 0 512
FLOOR-21A 23 X 24 552 0. 024 2 . 2 1, 219 0. 0 0 0
INFIL. W: 4. 5 S: 2 .2 8 56. 5 452 6. 1 0 49
ROOM T�TALS 3 , 121 0 561
2 . BASEMENT ENTRY 7. 0 WID X 12 . 0 LEN = H4 SF CEIL.HT = 9. 0
W -WALL-15H 9 X 12 108 0. 031 2 . 9 308 0. 0 0 0
S -WALL-15H 9 X 7 63 0. 031 2 . 9 180 0. 0 0 0
FLOOR-21A 12 X 7 84 0. 024 2 . 2 185 0. 0 0 0
INFIL. W: 0. 0 S: 0. 0 0 56. 5 0 6. 1 0 0
ROOM TOTALS 673 0 0
3. MID LEVEL 24 . 0 WID X 23 . 0 LEN = 552 SF CEIL.HT = 10. 0
W -WALL-12H 9 X 23 207 0. 060 5. 5 1, 143 1. 4 0 293
N -WALL-12H 9 X 24 156 0. 060 5. 5 861 1. 4 0 221
N -GLAS-3D 2-P O-1 S-1 100oS 18 0. 361 33 . 2 598 19 . 0 0 342
N -G.DR-8P 2-P 0-1 S-1 81%S 42 0. 361 33 . 2 1, 395 19 . 0 0 798
INFIL. W: 33 . 5 S: 16. 7 60 56. 5 3 , 387 6. 1 0 368
ROOM TOTALS 7 , 384 0 2, 022
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LAADS BY ELITE SOFTWARE *******
AIR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
STERIO/BRADLEY DUPLEX AUGUST 01, 1996 PAGE 5
*****�********************** DETAILED ROOM ZAADS ***********************��****
ITEM AREA -U- HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
--------------------------- ------ ------ ----- ------- ----- ------ -------
4 . MID LEVEL ENTRY 7. 0 WID X 12 . 0 LEN = 84 SF CEIL.HT = 9.0
W -WALL-12H 9 X 12 108 0. 060 5.5 596 1. 4 0 153
S -WALL-12H 9 X 7 20 0. 060 5. 5 110 1. 4 0 28
S -DOOR-lOD 7 X 3 . 5 25 0. 460 42 . 3 1, 058 10. 9 0 271
S -GLAS-3D 2-P 0-0 S-1 0%S 18 0. 361 33 . 2 598 32 . 0 0 576
INFIL. W: 24. 0 S: 12 . 0 43 56. 5 2, 427 6. 1 0 264
ROOM TOTALS 4 , 789 0 1,292
5. UPPER LEVEL 24 . 0 WID X 38 . 0 LEN = 912 SF CEIL.HT = 10. 0
W -WALL-12H 10 X 38 380 0 . 060 5. 5 2, 098 1.4 0 538
N -WALL-12H 10 X 24 158 0. 060 5. 5 872 1.4 0 224
S -WALL-12H 10 X 7 39 0. 060 5.5 215 1.4 0 55
S -WALL-12H 10 X 14 . 5 110 0. 060 5. 5 607 1.4 0 156
S -G. DR-9G 2-P O-0 S-1 0%S 21 0. 522 48 . 0 1, 009 38. 0 0 798
S -GLAS-3D 2-P 0-0 S-1 0%S 10 0. 361 33 . 2 332 32 . 0 0 320
N -GLAS-3D 2-P 0-0 S-1 OoS 8 0. 361 33 . 2 266 19. 0 0 152
N -GLAS-3D 2-P 0-0 S-1 0%S 8 0. 361 33 .2 266 19 . 0 0 152
N -GLAS-3D 2-P 0-0 S-1 0%S 24 0. 361 33 .2 �97 19. 0 0 456
N -G.DR-8P 2-P O-0 S-1 0%S 42 0. 361 33 . 2 1, 395 19. 0 0 798
S -GLAS-3D 2-P O-0 S-1 0%S 35 0. 361 33 . 2 1, 162 32 . 0 0 1, 120
CEIL-16H LIGHT 38 X 24 912 0. 026 2 . 4 2 , 182 0. 9 0 854
INFIL. W: 82 . 6 S : 41. 3 148 56. 5 8, 355 6. 1 0 908
ROOM TOTALS 19, 556 0 6, 531
. , .
�******* RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
AIR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
SmERIO/BRADLEY DUPLEX AUGUST 01, 1996 PAGE 6
************************* ZONE # 1 ROOM LOAD SUMMARY *************************
------------------------------------------------------------------------------
RM ROOM AREA ------ HEATING ------ ------ COOLING ------
N0. DESCRIPTION (SF) BTUH % TOT CFM BTUH % TOT CFM
------------------------------------------------------------------------------
1. BASEMENT 552 3 , 121 8. 8 41 561 5.4 26
2. BASEMENT ENTRY 84 673 1.9 9 0 0. 0 0
3. MID LEVEL 552 7, 384 20. 8 96 2, 022 19.4 92
4. MID LEVEL ENTRY 84 4 , 789 13 . 5 62 1, 292 12.4 59
5. UPPER LEVEL 912 19, 556 55. 1 254 6, 531 62.8 297
------------------------------------------------------------------------------
Z�NE SUBTOTAL 2 , 184 35, 523 100. 0 461 10, 406 100. 0 473
LATENT GAIN 0
ZONE TOTALS 35, 523 10, 406 0.867 TONS
------------------------------------------------------------------------------
»
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
AIR MAINTENANCE CO. , INC. GLENWOOD SPRINGS, CO 81602
S�ERIO/BRADLEY DUPLEX AUGUST O1, 1996 PAGE 1
************************* ZONE # 1 ROOM LOAD SUMMARY *************************
------------------------------------------------------------------------------
RM ROOM AREA ------ HEATING ------ ------ COOLING ------
NO. DESCRIPTION (SF) BTUH % TOT CFM BTUH % TOT CFM
------------------------------------------------------------------------------
1. BASEMENT 552 3 , 685 6.8 48 610 5. 1 28
2 . BASEMENT ENTRY 84 673 1. 3 9 0 0. 0 0
3 . MID LEVEL 552 11, 618 21. 6 151 2 , 390 19.9 109
4. MID LEVEL ENTRY 84 7, 824 14 . 5 102 1, 556 13 . 0 71
5. UPPER LEVEL 912 30, 000 55.8 390 7 , 439 62 . 0 338
------------------------------------------------------------------------------
ZONE SUBTOTAL 2, 184 53 ,800 100. 0 699 11, 995 100 . 0 545
LATENT GAIN p
ZONE TOTALS 53 , 800 11,995 1. 000 TONS
------------------------------------------------------------------------------
KKM [,oNSULTaNTS, IN�. 3039491577 P. �1
KRM G�ONSULTANTS, INC� �970) 949-9391
I'.O. 90iC 4572 FAX 949-1577
VAIL, COLORApt� 8'i 658
�.�.�,�,.�.�
�'AX TRANSMI7"TAL
DATE �� � ( ��
,
FAX T�:
1. NAME GHtJGiG. ��LCMAN _ 3. N.4ME
C�MPANY '�a� CQl1APA1VY
FAX 'E7 �( _ 2�52 FAX
2, NAME bON P�ES�L�.Y 4. NAME
COMPANY ^-A RP�t�rr�Y t�r��'rD, COMI�ANY
�AX - 47� - 30�! 7 �, FAX
.�
PR�JECT�T�-l�t� - l�i��DL�.Y JOB NUMBER __. �O�F ��,�
iVt�M6ER OF PAGES (INCLUDING Tf11S TRANSMITTAL) - - - `�
CQMMENTS: ��� ���� � � �,��-.; .~�� Y
.cc.s�C.
�
SIGNED """�—�._���
- .
KRM CONSULTANTC, INC. 3039491577 P. 02
KRM �Qr�su�.-rA�v-rs, INC. ie74) 949•8391
�.D. BOX 4577 FA% 9+�9-1577
VAIL, GQLORADO 81 B58
FIELD REPORT
T0: DATE�
�0_�3�� R�
GA�.�g,J�1T1�� �?tVLiMtTEI] � ARR11/E: a=40 14. M�
�.4 X �47 fa - 3 a�7 _ �EPART: g ; 3 D ,�.�[ .
�. .. wEATH ER: ��Ri 51.101n!1!.1 C�
ATTENTION:
bbhl P ,�, �55LE`( .
PROJECT; J08 NUMB�R;
_�TE�lL7 - BRs�D1_�`�' .DU_Pl.�.X �CdD�~ � � _
This was a f�n�l fraut�ina review for this project. Our previaus site visit, an i p12sl98, revealed some
items that raqu�rad corre�tian. Wich the exception af the exterior deck framinq. theae ltems have been
campleted ta our satisfaction, and no othar pro[slems have heen discovered. The exter(or deck framinp
was nnt dbn�BCCardinq ta the sfructura) dr�►wlnps, and some remadial wnrk is rw�uirnd. PlpacA see
the attached aketch.
;�" ''
! ��p0 R�E6�l�i�i
�o�•°'��1.v R~'rF'
�cs��� ; �
� •'� t�■ �
� �' ^'t � .
� � ' _'
., r��
9 S� ��%syti``
�°�FS•Sr�A��y��
'�
:�
SIGNED: CpPY TQ:
, L� TdUJf,! b� Vdl� � G�IUC� �'�i-DF.�AN
REYiEWED: _
KRM CONSULTANTB. IMC. 3ea9ayi5rr r. do
�
JOB S���!��� �� � Q � I. ,
KRM CON�UL�t�ANTS, INC.
P.O. BflX 4rJ7� 9MEET NO. �� . .. QF.-_M1..__�„
VAIL, GOLQRADO 81658 cq�cuurEO ev �Cf�N�
(970) 949-9393 '. °AT�
FAX (97Q) 949�1577 CHEGKED BY [SATE
Sca:e `� '� = f �O „ ,
, ,, ,
. �
.
�EVI SF p FRAM !l�JC� �4T' UP!'yFR I�E�� �
,
_ ,
;< € '...- �x(a F'a�T
f�DD 2x I o brocx
��HINA �A, �$ �� thP,�J-L�0!T5 "
E3a�r � �Zn `
q� �A
�
- _ ....—. ' l,..
� ' , ^
, ' _.�
i 'n
� . i ,
� � �ou��.� �.��'S ��r'�x � �.�., �
� y,��� ;
�!
, R�Mov� P�ssut��-� �
6�oGKlN,G� �TWRE. Joa,�75 �
AhtD �4f�D �IMt'�'aQhi A3�
C41r �A, S1D� R�{'�C� SlMP5Qf.} k�5
pR�&6UP_� iSl.O?i;.lhtc� �,r �A� alC��
�
v._ � i
_ � {,
r l�A3r �2�-� :
,1 � Q' x �,� �q�g '
, -�: 'rn �A. �o�T .,
bau5�.� �Kas y °
� ���, � ,
_ � ��
�
-�..�.„.�._....�._,�.
— �.� ,
��a x � c,.�. ;
,>
2.�t b i��.v�.K!N G �---M. '
,
,
�
7aP viF�J A- A
z
. . . . , ., ,,. : ;, r , ., .. . ,, . . , � .. . .: .. . .. . .. � ,, ,, . . . . . , - . :t _ ,. .. „ . . . . ..
+weadcr s7%�.4rnn�"c�,c:e�or++rs�rnr�.±a c�xr�w,ae ro�_rep=+�s[�a.E,sce�
B96-0164: Entries for Item:540 - BLDG-Final C/O 15:10 02/28/2013
Action Comments By Date Unique_
Ke
qp JRM 10/10/2008 A000118
586
Total Rows: 1
Page 1
�,,._,..�..�,�..,.,_-----—— — — — —
J
`./ -
1�-�� .
rI I
I Paga 6
� ; 02-21-2003 Inspectian Request Report� ir4g
_fi:50_am ._._____..___.___._ �_____.___e..�.._____.._.._iLA�IL.-C.Q..r?9�Vti�1_4�_._...�_.___.._._._._.__---------..._.�___�... ._.___�___._
� � Requesbed Inspect Dste: Friday�February Zt,7003
Insq�on Araa: CD
, 51te Add�sa: �76�B5 K{NICKINtCK RD�
� A,�+JIa Inbrma�an
, p,ctivHy: B9fi-016�4 TYfYe: &BUILD s��; VN��75� �' CpIIED
CW'1St Type: GkCUp�nCy: 0007 Phone;
� ' p�ics�t CARpENI'RY UNLIMITE�.ING
'OW11er: STERt�ROBERT W&DENYSE� P'hone: 3038263T53
I Qescr�: NEVY DtJPLEXUNLIMI'1'ED.INC
� I
Reau�sbed inspec�9�1�
� � lbsm: �37 PLAN-FINAL C/Q Requesbed Timo: 08:00 AM
`"� RaquesMr: KITCHEN C�?NNECTK?PJ Phone: 97a846-0262
A�n�d To: CiRUTHER Ent�e►ed By: JMONDRACON K
p�: Time Exp:
�..�
___------
I� : 589 PW-FIMA!_C!0 Requesteci Time: 08:00 AM
I ! Raq : K[TCHEN CONNECTION Phone: 970-846�0262
ei Assipn�d o: LS EM�ad 8y: .MA�PIDRAGON K
Exp.
' ,�. �/u/° 3
� ���
//= yS'A�c.
Inspectian HlsfiocY
`� '' IEem: 10 BL�F�ngsJSteal . EO App�oved'" �n: AF�PR MPRCfVED
Comnwnts: A�R�D
� I�em: 2Q BLDa-Faum�NordSteei '*�'��"� ��,; APPR APPRt�lED
08/01196 Ins CF
�� RTH d�E�T WALL �: PA PARTW.APPRWAI.
� , �,�;� S SEC O�F�,��QUNQA'TK)N �: APPR APPROVED
C�� APpROVEDGF q�q�: APPR APPROVED
I CommeM�: AP'pR01lED
�✓ , �em: 520 PLAI�-ILC 516e Plen f`qp�r°�� Acibn: APPR AF'PROVED
OA/2AJ96 p��' GEfJRG�
Cpmtnents: OVED
IMm: 30 8LD a1� • CD AcUon: /1PPR APPROVED
`'' C01r11riArItS: ` fT R ONLCF
9W26196 Iktion: DN DENIED
���� U��: �F qdlort: GO CERTtF�ATE OF OCCUPANCY
� ; 10/28196 A�
Comma►Ms: T1.CL)MMS-REMOVE fNSULATiON FGR iN8PEC71ON�R HAVE ENG OF REGt)RD
AppRpVAL FaR FRAMING
� ° ',�: It�am: 60 8L ia18/96 r. EC��avad"` ��: AppR APPROVED
�,,, � A�OVED�G q��: APPR APPR�D
r..ommants: un b oMy Actlon: APPR APPROdED
10/31l9S Insp�p� EG
�,,, Comtner►ts: API�ROVED �� �.R
; Ib�mm: tS0 BLa31S2�'k Netl . EG APP�OY� Actlon: APPR APPRC?VED
' CamRwMs: A�OVED �,�,�
" ; {tem: 'iQ BL.DG 712� {r►spector: EG� Action: DN DENIED
Ccmmenb: not ready Actlon: APPR APPROYED
12l841�6 Inspector: EG
� ._ --- -- -- — - -- �------- Rul1 Id: E
REPT131