HomeMy WebLinkAboutDRB130049 Plans.pdf semplebrown •
architecture I interiors I vision
semple brown design,p.c.
� 1160 Santa fe drive
UP (6 RISERS)
F
denver,Colorado 80204
A� �� �� ��SEE ELEVATIONS FOR 303.571.4137 ph
4 ]'SPIRAL STAIR MORE INFO ON E XISTIN 303-571-0403fx www N
AND NEW MECHANICAL .sbdesi n
EQUIPMENT s • `
MA SVI
UP (17 RISERS) � — � � — � / �
NO
4'-2" / / (18 RISERS
GENERAL CONST. NOTES
1 ' ROOF PLAN NOTES : 9 COPYRIGHT 2013
ANY UNAUTHORIZED USE OF THESE DOCUMENTS IS
1. ALL SUBCONTRACTORS ARE RESPONSIBLE TO REVIEW ALL I PROHIBITED WITHOUT THE WRITTEN CONSENT OF:
/ / ❑ REPLACE [E] DRAIN PIPES;TIE NEW ROOF DRAIN PIPES AND ARCHITECTURAL DRAWINGS AND INCLUDE ANY STRUCTURAL, I SEMPLE BROWN DESIGN,P.C.
1/8:12 / PROVIDE NEW INSULATION DOWNSPOUTS TO EXISTING STORM DRAINAGE SYSTEM ELECTRICAL, PLUMBING OR MECHANICAL CALLED OUT ON
AND FRAMING FOR ROUGH ARCHITECTURAL DRAWINGS THAT MAY BE MISSING FROM
SLOPE / / OPENING AS NECESSARY [TYP] ❑2 INTEGRAL GUTTER ENGINEERED DRAWINGS.
3 // 2. ALL DIMENSIONS ARE TO FINISH FACE OF WALL OR
�3
DEL DASHED LINE INDICATES LOCATION OF EXTERIOR WALL BELOW STRUCTURAL GRID LINE.
3. COORDINATE LOCATION OF ALL ACCESS PANELS
❑4 DASHED LINE INDICATES [E] EXTERIOR SOFFIT ABOVE W/ARCHITECT PRIOR TO INSTALLATION.
4. ALL FURNISHINGS AND KITCHEN EQUIPMENT ARE BY OTHERS.
HYDRONIC SNOW MELT SYSTEM EMBEDDED WITHIN CONCRETE G.C. RESPONSIBLE TO COORDINATE W/ KITCHEN DESIGNER,
5 / �/ ❑5 ROOF TOPPING SLAB DRAFT, POS, A/V, FURNITURE & BOOTH CONSULTANTS TO
PROVIDE OWNER W/COMPLETE PROJECT.
/ ❑6 42" H. AFF LAMINATED GLASS GUARDRAIL BY 'CL LAURENCE' [PHASE 2] 5. ASSUME ALL EXISTING FINISHES AND NON-STRUCTURAL
R- Q, FRAMING TO BE REMOVED IN LEVEL 1 COMMERCIAL UNIT'A'.
6 ll II ❑7 NEW ROOF DRAIN;TIE INTO [E] STORM DRAIN PIPE BELOW O
II
❑ [E] FLAT ROOF DECK STRUCTURE TO REMAIN
/ NEW 4-PANEL GLASS SLIDING
DOOR TO ROOF DECK; [E] SWEET BASIL 9❑ [E] DOWNSPOUT FROM UPPER ROOF TO REMAIN
p // RE: MANUF. FOR DOOR SIZES - - - -
2� - - - NIC 10 [E] DOWNSPOUT TO BE RELOCATED; NEW COLLECTION BOX AT J
- / �� ❑ SOUTH ROOF EDGE - - - - - - - - - - - >
/ FURS OUT [E] COLUMN TO [E] SWEET BASIL
2 5- I ACCOMMODATE NEW DOOR JAMB; �8
w /
FINISHES TO MATCH EXISTING +1 10'-0" [8168'-10"] O
w 0
n � / 3 I /
QZ I II I W
z I I II / I I I I
/ FP [E] EV R
jj�LLl / / II
2 [E] CORRIDOR Uj
O1/8:12 / NEW 4-PANEL GLASS SLIDING 204 >
$LOPE 11 ^ DOOR TO ROOF DECK; [E] CORRIDOR
�/ I % (� RE: MANUF. FOR DOOR SIZES 201 UP (4 RISERS) � z
� II II I � Q � 'W
REMOVE [E] BASEBOARD HEATERS; In >
NEW HEATING PROVIDED BY
W I 1 I /I RADIANT FLOORING FROM BELOW [E] VESTIBULE W
Uj / [E] FLOOR SLAB F200 w 1 1 1 Q
r I / [E] CLOSET
[E] ADA WASHROOM �1
U / PROVIDE NEW INSULATION AND 203 201 I [E] MENS WASHROOM W
/ FRAMING FOR ROUGH OPENING AS
Uj / / NECESSARY [TYP] 201 Uj
�/ Q/ CC
O O w U
C� 7
W w
_ Ln
LO
1
O
`V NOTES: - - - - - - - - - -. - - 6�
1. SWEET BASIL RESTROOM RENOVATIONS ARE NOT
- - INCLUDED IN LEVEL 1 PLUMBING FIXTURE COUNTS W O
2. REPLACE ALL FINISHES, PLUMBING & LIGHTING (n
FIXTURES IN [E] SWEET BASIL RESTROOMS [TYP] v
R2 J
8
PLAN LEGEND O W m Q
NEW WALL CONSTRUCTION ON >
I
EXIST. CONSTRUCTION TO REMAIN
00 I D ISSUED FOR DATE
FOR PERMIT 2012.0E
Z COMMENTS 2012.0E
Z EXIST. DOOR TO REMAIN ADDENDUM 1 2012.05
x ASI-001 2012.1 C
ASI-002 2012.11
� I CONSTRUCTION 2013.0
7
f 1 I I I
NEW DOOR 1
I I
I I
I I
9 10
I I
�-- --j
PROJECT NO. M
120600 2013.02.1
DRAWN CHECI
S
LEVEL2 FLOOR PLAN 0 2' 4' 8' SHEET TITLE
LEVEL 2 FLOOR PLAN
1/4"=V'-0" SHEET NO.
TRUE PROJECT A � •
NORTH NORTH
semplebrown •
architecture I interiors I vision
Semple brown design,p.c.
1160 Santa fe drive
deriver,Colorado 80204
303.571.4137 ph
303-571-0403 fx
www.sbdosign-pc.com
0 .
Y
8218'- 0 3/4"
T.O. PROJECTION i
j ,
t�-
8215'- 0 3/4" Y
T.O.R.
'COPYRIGHT 2010
8214'-6 3/4"
ANY UNAUTHORIZED USE OF THESE DOCUMENTS IS:
_ _ _
PROHIBITED WITHOUT THE WRITTEN CONSENT OF
DECK BR G. SEMPLE BROWN DESIGN,P.C.
8208'-10"
DECK BRG.
� 8198'-10"
PENTHOUSE Q
Ff 11 1 1 111 11 1 1 111 11 1 1 111 11 1 1 111 11 1 1 111 11ITTE]
z_
o O
0o
z
X
U-1 W
Ll IT F
8188'-10" z III
LEVEL 4
Ll Q \w
z
W 0
Uj
w
W U
8178'-10" Uj
� W
LEVEL 3
Ln
13 � �
UO
�
00
1
1 14 W O
3 w
w V'
z =
CL W J 11 O
II II II II I II II II II II I
C0 � Q
II II II II I II II II II III I V _
8168'-10" L - - J - - - J - - - - - - - D - - - L - - - L_ _J11 I
LEVEL 2
6 0
`V D ISSUED FOR DATE
O NEW GLASS GUA RAIL BY CL COMMENTS 2012.0E
8167'-1" U 14 AURENCE OR I A [PHASE 2] ��� ADDENDUM 1 2012.05
SWEET BASIL ENTRY = w D 7 C �� D D D ASI-001 2012.1C
N \� ASI-002 2012.11
zz _ /% /% /� /� _ ° /% \� � /% o CONSTRUCTION 2013.0
U ° 102 j /
3 \�\�
LU = _ _ � _ = =II _ _ _ _ _ _�_ _ _
48"
77:1111 I = _ =
8158'-10" - - -
LEVEL 1/GARAGE
12 2 1 9 1 4 5 STEEL PLATE 3 $ 2 1 9 2 5
DOOR
EXISTING BUILDING NEW CONSTRUCTION
ALIGN CENTER OF BALUSTERS W/
NORTH BUILDING ELEVATION NEW 0 2' 4' 8'
EXTERIOR DOOR FRAME PATTERN [TYP] 1
1-1/2" DIA ROUND
STEEL PIPE [TOP & GENERAL NOTES : ELEVATION KEY NOTES : LIGHT FIXTURE LEGEND
BOTTOM RAIL]
1/2"x ]-1/4"STEEL 1. ALL EXTERIOR ALUMINUM STOREFRONT FRAMING, 1 NEW DARK BRONZE ALUMINUM & GLASS SLIDING g NEW STONE VENEER WALL PANEL A NEW WALL SURFACE MOUNTED DARK BRONZE
_ BAR ENTRANCES, AND SLIDING DOORS TO BE ANODIZED DOOR BY 'FLEETWOOD'. ALUMINUM UP/DOWN LIGHT;
X 1/2"xl/2"VERTICAL STEEL DARK BRONZE FINISH. MODEL# HL-374-2X-AA-120 BY HEVI-LITE
BAR @ 6"O.C. [MAX] 2. ALL EXTERIOR STOREFRONT SYSTEMS BASIS-OF NEW HOT ROLLED, CLEAR POWDER COATED STEEL NEW DE-MOUNTABLE 36" H. PAINTED STL PATIO
DESIGN: EFCO SERIES 403 WITH ENHANCED WALL PANEL GUARDRAIL TO ALIGN W/VERTICAL DOOR FRAMES [TYP]
B NOT USED
MAX 12" RETURN THERMALLY BROKEN FRAMES. NEW DOUGLAS FIR PLANK SIDING [STAINED & 10 EXISTING STUCCO WALL SYSTEM ❑ PROJECT NO. M
NOTES: EXTENSION AT 3. ALL EXTERIOR GLAZING TO BE 1-INCH, CLEAR, SEALED] 120600 2012.08.2
1. EXTERIOR GUARDRAIL TO BE CORNERS LOW-E INSULATED GLAZING. BASIS OF DESIGN: NEW HOT ROLLED CLEAR PWDR COATED STEEL DRAWN CHECI
POWDER COAT FINISH TO 2" DIA. GALVANIZED STEEL SOLARBAN 60 CLEAR BY PPG [OR EQ]. ❑4 WIDE FLANGE COLUMN 11 EXISTING WINDOW SYSTEM `
MATCH WINDOW FRAMES. PIPE SLEEVE FOR BALUSTERS NEW DARK BRONZE ALUMINUM CEILING
C
2. SEE 4/A7.0 FOR MORE INFO. 4'-0" [MAX] [MIN 6" EMBEDMENT] �5 NEW ALUMINUM STOREFRONT GLAZING SYSTEM 12 EXISTING PAINTED EXTERIOR STAIRS [NIC] RECESSED DOWN LIGHT; SHEET TITLE
MODEL# 102050130 BY RICHELIEU
NORTH ELEVATION [NEW]
TYI L 0 1 2 4 ❑6 [BY JAMS HARD E [OR SIM]CEMENT BOARD FASCIA 13 EXISTING PAINTED WOOD FASCIA ALU NUM DOWN LIGHT; DARK BRONZE SHEET NO.
P I CA L PATIO GUARDRAIL D ETA
2 1/2"-1'-0" NEW DOUGLAS FIR PLANK SOFFIT [STAINED & MODEL# HL-340-AA-12-LA BY HEVI-LITE A205
❑7 SEALED] 14 EXISTING EXPOSED STEEL COLUMN