Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A13-0012 Cut Sheets.pdf
0 11 nim Gamewell 11195-E3 FIRE CONTROL INSTRUMENTS Series by Honeywell Description Intelligent Loop Interface-Main Board IL195-MB-E3 e The Intelligent Loop Interface-Main Board (ILI95-MB-E3)is the main interface for the E3 Series®product line. With its state-of-the-art 32 bit RISC processor, this compact"panel , on a board" provides a powerful addition to Gamewell- FCI's single pair conductor solutions. This intuitive design T„7 provides two (2), signaling line circuits,two(2), notification appliance circuits, local energy city box output, auxiliary relay functions, and auxiliary power output. These fea- tures, combined with built-in network and serial protocols, allow this module to support a host of new and existing products, resulting in a building block approach to fire ILI95-MB-E3 alarm panel design. Features The ILI95-MB-E3 is network ready and occupies sixty-four ILI95-MB-E3 and ILI95-S-E3: (64) nodes, operating at 625K baud. In addition, the Listed under UL®Standard 864, 9th Edition Addressable Node Expander (ANX) board expands the Network ready integral 625K baud ARCNET network to one hundred and twenty-two (122) nodes. When this sub-assembly is integrated with proven Broad- 115.2K baud RS band components, the result is a flexible yet powerful inte- grated audio solution. When transmitting to remote -Two(2), Class A, Style 6, 7*or Class B, Style 4 locations, the optional RPT-E3 provides the ILI95-MB-E3 circuits with valuable signal boosting and transient protection, as -40 Character user-defined text per device well as connectivity using both wire and fiber-optic cables. -Capacity of 126 analog/addressable devices per loop • 4100 event history log The ILI95-MB-E3 provides two (2), signaling line circuits *Style 7 wiring requires the use of XP95-LI Isolator and terminals for the connections to up to (126) Apollo detectors and modules per SLC.The RS-485 interface can Modules. support up to a total of six (6) LCD-E3 and sixteen (16), ILI95-MB-E3 Only: ASM-16 and/or sixteen (16), ANU-48 remote LED driver Two(2),notification appliance circuits,Class"A",Style Z modules. or Class B, Style Y rated at 2.0 amps. per circuit • RS-485 supporting sixteen (16), ASM-16 switch The ILI95-MB-E3 relay outputs include system alarm, modules and/or ANU-48 LED driver modules supervisory, and system trouble contacts. The ILI95-MB- Alarm, trouble, and supervisory dry contacts Form"C", E3 provides output for a local energy city master box or rated at 2 amp. @ 30 VDC (resistive) remote location which is non power-limited.All other wiring Supports six(6),local/remote LCD-E3 annunciators and is power-limited. five (5), LCD-7100/RAN-7100 remote LED annunciators An ISO 9001-2000 Company SIGNALING E3 Series ,NetSOLO and Velociti are registered trademarks of Honeywell International Fnn Ap EA n Approved Inc. LISTED APPROVED FDNY: � UL®is a registered trademark of Underwriters Laboratories Inc. S186e 3025415 COA-#6077 7165-1703:0125 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60336 Rev. H page 1 of 2 Specifications ILI95-MB-E3 Operating Current: 0.050 amp Alarm Current: 0.091 amp max. ILI95-S-E3 Operating Current: 0.109 amp Alarm Current: 0.11 amp ILI95-MB-E3 and ILI95-S-E3 Operating Voltage: 24 VDC FWR(from the PM-9/ PM-9G Power Supply) Operating Temperature: 32°to 120° F(0°to 49°C) ILI95-S-E3 Relative Humidity: 0 to 93%, non-condensing ILI95-S-E3 at 90° F (32° C) The Intelligent Loop Interface - Expansion Board (ILI95-S- Supervised E3)provides the E3 Series control panel with two(2),addi- Power-limited tional signaling line circuits. The layout is similar to the SLC 40 Ohms maximum line impedance. ILI95-MB-E3 except a number of components are omitted. 0.5 pf maximum line capacitance. The ILI95-S-E3 occupies one node on the Broadband net- work. The ILI95-S-E3 provides two (2), signaling line cir- Ordering Information cuits and terminals for the connections to up to 126 sensors/modules. Part Number Description Installation ILI95-MB-E3 Intelligent Loop Interface-Main Board Typically, the ILI95-MB-E3 or ILI95-S-E3 can be mounted ILI95-S-E3 Intelligent Loop Interface-Expansion Board in the following E3 Series cabinets: • Cabinet B and D, backbox • Cabinet B, B-Slim-E3 sub-assembly plate • Cabinet C, E3-ILI-C sub-assembly plate • Cabinet C, E3-INCC-C sub-assembly plate • Cabinet C, E3-INX-C sub-assembly plate • Cabinet D, E3-INCC-D sub-assembly plate • Cabinet D, E3-INX-D sub-assembly plate For installation instructions on the ILI95-MB-E3 or ILI95-S-E3, refer to the following documents: • E3 Series®Expandable Emergency Evacuation Installation/Operation Manual, Part Number: 9000-0574 • ILI95-MB-E3 Installation Instructions, Part Number: 9001-0017 • ILI95-S-E3 Installation Instructions, Part Number: 9001-0018 For information on the ANX, refer to the Data Sheet Part Number: 9021-60497. For additional information on the ILI-MB-E3 or ILI-S-E3, refer to the following document: • ILI-E3 Series Data Sheet, Part Number: 9020-0605 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 F9021-60336 Rev. H page 2 of 2 www.gamewell-fci.com Gamewell MS95-L Series FIRE CONTROL INSTRUMENTS by Honeywell Description Addressable XP95 Manual Pull Stations The Gamewell-FCI MS95-L Series is a state-of-the-art,sin- gle-or dual-action XP95 pull station that includes an XP95 addressable interface for any Gamewell-FCI 600 Series Fire Alarm Control Panel (FRCP). Because the MS95-L PUSH IN Series is addressable, the FACP can display the exact IP LLD.WNI location of the activated manual station. This display leads fire personnel quickly to the location of the alarm. Operation Pushing in, then pulling down on the handle causes it to FCI latch in the down/activated position. Once latched, the word "ACTIVATED" (appears in bright yellow) at the top of MS95-L the handle,while a portion of the handle protrudes from the Features bottom of the station.To reset the station, simply unlock the station with the key and pull the door open. This action Meets UL Standard 38,for manually actuated resets the handle; closing the door automatically resets the signaling boxes switch. Each manual station, on command from the control Maintenance personnel can open the station without panel, sends data to the panel representing the state of the causing alarm condition manual switch.The DIP switch is used to set addresses. Built-in bi color LED,which is visible through the handle of the station,flashes in normal operation and Construction latches steady red when in alarm • Handle latches in down position and the word Shell, door, and handle are molded of durable LEXAN®(or "Activated"appears to clearly indicate the station has polycarbonate equivalent)with a textured finish. been operated • Captive screw terminals wire-ready for easy connec- Installation tion to SLC loop(accepts up to 12 AWG/3.25 mmz wire) The MS95-L Series will mount semi-flush into a single- Semi-flush, mounts to a standard single gang (2.125" gang, double-gang,or standard 4"(10.16 cm)square electri- [5.3975]minimum depth), double gang,or 4"(10.16 cm) cal outlet box, or will surface mount to the Model SB-10 square electrical box surface backbox. If the MS95-L Series is being semi-flush Smooth dual-action design with key reset mounted,then the optional trim ring (BG-TR)may be used. Within ADA 5 lb. pull force The BG-TR is usually needed for semi-flush mounting with Highly visible, attractive shape and textured finish 4" (10.16 cm) or double-gang boxes (not with single-gang NYC backplate provided for manual pull station boxes). Braille text imprinted on the station handle • Optional trim ring (BG-TR) Engineer's Specifications Up to 126 stations per XP95 loop Manual Fire Alarm Stations shall be non-coded,with a key- An ISO 9000-2000 Company SIGNALING operated reset lock so that they may be tested, and are & Lexan®is a registered trademark of GE Plastics,a subsidiary of General Electric Company. LISTED GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2008 Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2487 Rev.A2 page 1 of 2 Engineer's Specifications (Continued) Specifications designed so that after actual Emergency Operation, a key Normal Operating can be used to restore it to"Normal." Voltage: 24 VDC Maximum SLC An operated station shall automatically condition itself so Circuit Voltage: 28.0 VDC as to be visually detected as activated. Manual stations Maximum SLC shall be constructed of red-colored LEXAN® (or polycar- Circuit Current: 170 mA bonate equivalent) with clearly visible operating instruc- Standby Current: 0.0005 A tions provided on the cover. The word FIRE shall appear Alarm Current: 0.0015 A on the front of the stations in white letters, 1.00 inches Ordering Information (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-1/0; or semi-flush mounting on a standard single-gang, double-gang, or 4" Model Description (10.16 cm)square electrical box,and shall be installed within MS95-SL XP-95 pull station, single with key the limits defined by the Americans with Disabilities Act MS95-DL XP-95 pull station, dual with key (ADA) or per national/local requirements. Manual Stations SB-1/0 Surface box shall be Underwriters' Laboratories Listed. BG-TR Optional trim ring NY-PLATE NYC backplate for manual pull station Manual stations shall connect with two wires to one of the control panel SLC loops.The manual station shall,on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the "Normal" condition, and remain steadily illuminated when in alarm. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NY-Plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2487 Rev.A2 page 2 of 2 www.gamewell-fci.com Gamewell NGA FIRE CONTROL INSTRUMENTS by Honeywell Description NGA Network Graphic Annunciator The NGA LCD Graphic Annunciator is a powerful, yet attractive component of the Gamewell-FCI emergency voice evacuation systems. The bright, back-lit 1/"VGA GarneuueA display is supplemented with an intuitive, easy-to-used touch-screen interface that provides the following features: • Up to 512 user-defined messages may be configured. System Normal • Messages may be up to 77 characters in length. • Display font and color may be selected for each message. The NGA mounts in NetSOLW and E3 Series®enclosures or it can be remotely located. It occupies one (1), standard Me BASS RSr slot in the cabinet and directly connects to the INI-VGC or RPT-E3 eliminating the need for a separate ARCNET inter- face. The NGA occupies one node on the Broadband net- NGA work. Features The back-lit LCD display indicates events stored in the sys- tem event log, the status of analog addressable monitor Listed under UL Standard 864, 9th Edition and control points and provides diagnostic fault codes/ 1/4"VGA display multipurpose touchscreen provides messages. the following options: -Up to 512 user-defined messages may be configured The attractive, state-of-the-art display is user-friendly, -Messages can be up to 77 characters in length easy-to-read and affords the end-user with the means to -Display font and color may be selected for each perform numerous functions via the touch-screen feature message which is software programmable. Some switch functions Software programmable touch-screen interface are: Acknowledge, Signal Silence, Reset, Log Events, and system maintenance functions. Mounts in NetSOLO°and E3 Series°command center mounting spaces or enclosures Additional LEDs located on the display panel perimeter 625K baud ARCNET communications indicate Power On, Alarm, System Trouble, Supervisory User-friendly design and Ground Fault conditions. RS-232 interface Specifications Ordering Information Operating Voltage: 24 VDC from PM-9 power supply Operating Current: 0.200 amp.* Model Description Alarm Current: 0.200 amp. 1100-0505 Network graphic annunciator Operating Temperature: 32°to 120° F(0°to 49°C) Relative Humidity: 0-93% non-condensing at 90° F (32° C) An ISO 9000-2000 Company *Normal operating current. During power failure, current SIGNALING —� �7, drops to 0.045 amp, since the back light is extinguished. �� FM ,'���} �„�•, O M EA a Chi-g. City Of ® LISTED APPROVED Approved — Aass1 d Approved E3 Series and NetSOLO C are registered trademarks of Honeywell International Inc. 51869 3025415 231-06-E 7165.0694:268 c„",, 7165.0694:269 Hign Rise GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0598 Rev.i1 page 1 of 1 Gamewell P10=95PP P18=95 FIRE CONTROL INSTRUMENTS by Honeywell Description Point Identification Device The Gamewell-FCI PID-95P addressable point identifica- tion device is the interface between the non-powered, nor- mally open, dry-contact devices and Gamewell-FCI's 600 Series and IL195-E3 Series° of analog addressable Fire Gameoll-FCIa''. Alarm Control Panels (FACPs). Point identification devices 11.11 L1 �R monitor a single Style B circuit, and are designed for con- cealed mounting in an electrical backbox.The PID-95P can i" a 51 be surface or flush mounted and has a visible LED for 0 53 alarm/annunciation. Operation The point identification device connects to the Signaling PID-95P PID-95 Line Circuit (SLC) via two wires. The PID-95 will monitor, via a two-wire supervised SLC circuit, contact-type devices Features such as a waterflow switch or a manual station. Upon acti- vation of the monitored device, the PID-95 will report its address to the 600 Series and IL195-E3 Series FACP via Compatible with the Gamewell-FCI, 600 Series and the analog SLC. The control panel will then activate into all IL195-E3 Series Systems alarm programmed outputs related to the PID-95. Monitors dry-contact devices Programming LED for alarm annunciation • Field programmable The PID-95 is programmed by setting a single DIP switch, Priority interrupt easily accessible on the device's printed circuit board. The Plate-mounted version available for surface or flush DIP switch sets the address of the device and the priority mounting in a 4"x 4.688"(10.16 cm x 11.908 cm)double interrupt (DIP SW #8). All other programming is accom- plished at the FACP through a laptop computer or the con- trol panel operator's display. (600 Series only). Standard Application The PID-95 is the interface between the dry-contact type devices and the SLC of the control panel. The PID-95 is a means of connecting and identifying monitor points without the use of conventional input modules at the main control panel.The use of PID-95s can dramatically reduce the field wiring required on many projects. An ISO 9000-2000 Company SIGNALING E3 Series®is a registered trademark of Honeywell International Inc. @ fO FM Microsoft®Windows®is a registered trademark of Microsoft®Corporation. LISTED MEA S521 APPRoveo Approved 7300-1703:135 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2008 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2044 Rev.B page 1 of 2 Engineer's Specifications Ordering Information Addressable interface devices shall be provided for the monitoring and supervision of contact type devices con- Part Number Description nected to the Fire Alarm Control Panel. The devices shall PID-95 Addressable point identification device monitor a normally open dry contact. The addressable for monitoring contact devices interface devices shall communicate to the main control PID-95P Addressable input interface device panel via the analog addressable circuit. The interface mounted on 4.688"(11.908 cm) plastic plate device shall be Gamewell-FCI PID-95P or PID-95. 70839 Trim ring for flush-mounting on the PID-95P Specifications PID-95P Standby Current: 0.0005A, 0.0008A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F(0°C to 49°C) Relative Humidity: 93%, non-condensing Dimensions: 4"x 4.688"(10.16 cm x 11.908 cm), double gang backbox PID-95 Standby Current: 0.0005A, 0.0008 A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F(0°C to 49°C) Relative Humidity: 93%, non-condensing Dimensions: 4"(10.16 cm)square backbox with blank cover plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2044 Rev.B page 2 of 2 www.gamewell-fci.com _ Gamewell NCE=95 FIRE CONTROL INSTRUMENTS by Honeywell Description Relay Control Elements The Gamewell-FCI Relay Control Element(RCE-95)is the interface between the Gamewell-FCI, 600 Series and IL95-E3 Series° Fire Alarm Control Panel (FACP) analog circuits and building functions such as door holders,eleva- Gamewell-FCI tors, dampers, motors and disconnects. The RCE-95 6E 6mx�� L1p R0 offers feedback input points for positive confirmation of the L2 2 MD AMP controlled device's activity. For annunciation and feedback DOM at the panel, Gamewell-FCI offers a Relay Control Display FB- o NO (RCD). The RCD is only available with the IdentiFlex 632 and IF650 FACPs. The RCE-95 can be either surface or flush mounted and L L Ak — has an integral LED which annunciates upon device RCE-95 activation. Features Operation The devices connect to the SLC circuit of the FACP via a Compatible with the Gamewell-FCI, 600 Series and two-wire non- polarized circuit. In its quiescent mode, the IL195-E3 Series analog addressable FACPs RCE-95 monitors its internal circuitry for status of the device itself and supervises an external control circuit for Form-C dry relay contacts status. Event or manual controllable relay functions When a status change is detected, the event can be pro- Positive feedback of relay activation grammed to display on the optional RCD module (IF632 LED annunciates activation and IF650 only). When an event is reported to the control Fully supervised panel that requires the activation of the RCE-95, the con- trol panel communicates via the analog circuit to the RCE- Surface or flush mounting 95 for activation. The integral LED is also lit for annuncia- Field programmable tion at the device. Style 4, 6, or 7 wiring Programming Screw terminals for field wiring connections The RCE-95 is programmed by setting a single DIP switch easily accessible on the RCE-95's printed circuit board. The DIP switch is used to set the address of the device.All other programming is accomplished at the Fire Alarm Con- trol Panel, either through a laptop computer or the control An ISO 9000-2000 Company panel operator's display. (600 Series only). SIGNALING E3 Series®is a registered trademark of Honeywell International Inc. &,�� '0`MEA sE•' Microsoft®Windows®is a registered trademark of Microsoft®Corporation. LISTED S521 APPROVED Approved 7300-1703:135 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2008 Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2045 Rev.B page 1 of 2 Mounting Ordering Information The RCE-95 is designed to mount in a standard 4.688" (11.908 cm) electrical backbox. The RCE-95 should be Part Number Description mounted in an easily visible location so that the built-in RCE-95 Relay control element device.XP95 LED indicators may be easily seen and display the proper protocol compatible. connection and device activation. 70839 Trim ring for flush mounting the RCE-95. RCD Optional relay control display; provides Engineer's Specifications annunciation of the RCE-95 control ele- ment devices at the FACP. One needed for A programmable interface device shall be provided for the every eight RCEs. control and status reporting of programmed relay control functions. The RCE-95 shall communicate with the Fire Note: The Relay Control Display (RCD) is only compatible Alarm Control Panel via an analog circuit(SLC)over a with the IF632 and IF650 FACPs. single pair of wires. The device shall provide dry contacts and positive feed- back of the controlled equipment's status annunciating upon activation. It shall be Gamewell-FCI RCE-95. Specifications Input Power: 24 VDC from analog circuit Standby Current: 0.0008A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F(0°C to 49°C) Relative Humidity: 93% non-condensing Fuse: 2 amp Slo Blow Contact Rating: 2.0 amp at 30 VDC 0.2 amp at 120 VAC Dimensions: 4.688"(11.908 cm) backbox GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2045 Rev.B page 2 of 2 www.gamewell-fci.com Series 95 Bases amewell FIRE CONTROL INSTRUMENTS by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base, the XP95 *� family has a base to meet building aesthetics, constraints, retrofit limitations or functional needs. The device address • . is held in the base, ensuring that the device address will not be changed no matter how often a detector is replaced, and verifying a consistent match between device type and + - . 3 device address. 0 #, N Each XP95 analog addressable head is compatible with a - °° U) wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only" fit. Relay and sounder bases can be addressed and Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. Base options include: — 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile Programming bases feature'one-way'fit with low insertion force — 6.0"(15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base head is inserted into the base,the address is automatically Address is set by patented XPert addressing card relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors. The bases SIGNALING have a wide interior diameter for ease of access to wires @ and terminals.The design of the base is such that the LISTED 51195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.a1 page 1 of 2 Installation (Continued) Specifications (Continued) sensor will fit in only one way, and a simple clockwise motion(without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Model: XP95-136R4 XPert addressing card as a means for programming and Alarm Current: 0.0036 A maintaining the sensor's address. Standby Current: 2 NA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-134 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Captive Terminals: Yes cover/plaster ring (Raco 727 or equal).The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5" (8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model: XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030 A square backbox(Raco 190 or equal). Standby Current: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048 m) Captive Terminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-1) or photoelectric (Gamewell-FCI model XP95-P) smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-64 4.0"(10.16 cm) mounting base with model XP95-T)with one of the several addressable mount- XPert addressing card in base available options. The combination sensor head XP95-66R4 6.0"(15.24 cm) relay base(four- g p wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0"(15.24 cm) ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED (24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: X1395-134 Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes 6" Base Model:XP95-B6EZ Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2048 Rev.a1 page 2 of 2 www.gamewell-fci.com XP95-P amewell - FIRE CONTROL INSTRUMENTS by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- tric sensor operates with the Gamewell-FCI analog addres- sable Fire Alarm Control Panels (FACPs). The IS t photoelectric sensor digitally transmits its address and the 1 chamber's analog values to the FACP for analysis. The photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled and turns on continuously when the device is in alarm.Operation own(:) 3 The XP95-P photoelectric sensor constantly monitors its co sensing chamber and its internal electronics. The results are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber. When Fits 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra-low-profile smoke enters the chamber, it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- Audible alarm sounder base acteristics and density. As the smoke content in the cham- Four-wire relay base ber increases, the signal from the photo diode receptor Address is stored in the sensor base increases. This information is processed and conditioned Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally Two-color status LED transmitted to the FACP. Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. FM MEA LISTED Approved 51195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2054 Rev.a1 page 1 of 2 Operation (Continued) Ordering Information The XP95-P photoelectric device is connected to a two- Model Description wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor, analog voltage, and is insensitive to loop connection polarity. A addressable (55000-650) remote LED indicator may be connected. The device is XP95-1134 4.0"(10.16 cm)mounting base with compatible with point-or group-addressable relay and XPert addressing card (45681-2101) sounder bases. XP95-1136R4 6.0"(15.24 cm)relay base (four-wire)with XPert addressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install, where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available. The 30203 Remote LED (24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications Standby Current: 340 pA Alarm LED Current: 0.00434 A Remote Alarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F(0° C to 60° C) Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft. (9.1 m)spacing guidelines in NFPA 72 Chapter 2. However,this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.a1 page 2 of 2 www.gamewell-fci.com XP95-T amewell - FIRE CONTROL INSTRUMENTS by Honeywell Description Analog Addressable Thermal Sensor The Gamewell-FCI XP95-T Analog Addressable Thermal Sensor operates with the Gamewell-FCI 600 Series analog addressable fire alarm control panels (FACPs). The Series t XP95-T thermal sensor digitally transmits its address and the chamber's analog temperature value to the FACP for analysis. Thermal sensors are readily distinguished from smoke by 1p"the open webs in the housing designed to allow for freemovement of air around the exposed thermistor. 3 Operation co a U The XP95-T thermal sensor constantly monitors its sens- XP95-T ing element as well as its internal electronics. The results are digitally reported along with the unit's address through the integral communication electronics located in the sen- Features sor head. The thermal sensor monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. This Compatible with the Gamewell-FCI 600 Series analog signal is processed and conditioned by an on-board addressable control panels advanced technology ASIC that digitally transmits the Fits 4.0"(10.16 cm)or 6.0"(15.24 cm) ultra low—profile, ambient temperature data to the FACP when interrogated. and E-Z fit bases • Audible alarm sounder base Trouble and Alarm conditions of the XP95 sensors are Address is stored in the sensor base determined at the FACP. The status information of each Address is set by XPert addressing card sensor is analyzed for off—normal conditions by the control Two-color status LED panel. If the sensor reports a condition that matches its Fixed point or rate-of-rise functions programmed trouble signature, the FACP will report that Timed temperature increase causes an alarm the sensor is in trouble and will follow its programmed Thermal adjustability programming response sequence. Likewise, if the status reported Optional remote LED matches the alarm signature, the FACP will follow the pro- grammed alarm response for the specific device in alarm. When a sensor is in alarm,the integral LED in the sensor's housing will light continuously. The XP95-T thermal sensor is calibrated to return a normal air temperature analog value to the FACP at 77° F. The An ISO 900 device connects to a two—wire loop circuit carrying both SIGNALING Company data and a 117 to 28 VDC supply voltage, and is insensi- tive to loop connection polarity. LISTED FM S2$27 APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2055 Rev.a1 page 1 of 2 Operation (Continued) Ordering Information A remote LED indicator can be connected. The device is compatible with point or group—addressable relay and Model Description sounder bases. XP95-T Thermal sensor analog addressable (55000-450) Engineer's Specifications XP95-136EZ 6.0"(15.24 cm) ultra—low—profile EZ-Fit mounting base with XPert card The contractor shall furnish and install, where indicated on (45681-250) XP95-134 4.0"(10.16 cm) mounting base with XPert the plans, electronic thermal sensors with one of the sev- Addressing Card (45681-210) eral addressable mounting base options available. The XP95-B6R4 6.0"(15.24 cm) relay base(four-wire)with combination sensor head and twist—lock mounting base XPert addressing card shall be UL Listed and UL Listed as compatible with the XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert Gamewell-FCI 600 Series analog addressable fire alarm addressing card and audible alarm sounder control panels. 71112 Additional blank XPert addressing cards The base shall permit free interchange of sensor heads 30203 Remote LED (24 V) without requiring any additional wiring or additional pro- gramming of the head or base.The sensor shall contain an integral LED that shall latch in when the unit goes into alarm. It shall be the Gamewell-FCI model XP95-T. Specifications Standby Current: 250 pA Alarm LED Current: 4 mA Remote Alarm Output: 4 mA @ 5 VDC Temperature Range: -4°F to 154°F Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Smooth ceiling 60ft. (18.288 m)to walls 25 ft. (7.62 m) Thermal Sensor Performance Features: 1)Thermal sensors have a thermal adjustability programming range from 25°C to 90°C (77°F to 194°F)in 1°C increments. 2)Thermal Sensors have a thermal rate-of-rise feature.When enabled in programming, should the XP95-T sensor increase temperature by greater than 15°F in less than one minute, an alarm will be generated. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2055 Rev.a1 page 2 of 2 www.gamewell-fci.com