HomeMy WebLinkAboutF13-0010 CS1810 Villa Valhalla Retrofit Submittal �+!�'�►:��� �` ° Department a�Camm�nity De�elopment
� '� �?�.`�� �"�. � � � T� �' ,; 75 Svuth Frontage Raaci
.�
' � , �`° �;�-�� ,�:���' �-�'� � '�° Vail, Co��rado 81G57
.,;; "�•� �''� ' �,`��'� � �r�1�� � . Tei: 9?0-479-2128
�� ,� � ., , .� =��' s �����`� F�x: 97{}-479-2�k5�
� `�k=�. �. �
il* � �-;-;� . � 1._�`: �- r�,a�",�' W�b: wwuw.vaiig4v.cc+m
- r �'"� . ._- � - Development Rew�euv Coardinatar
��, � F ,
. �.- a-� .a�
— .��
FIE�E SP'RINHCLER PERMIT
Cornmer�ial &Residerotial Fire Alarm shop drawings are required at the time of
applicatiqn subrnitt�l �nd must include#he follawing fimfvrrtt�tivn:
1. A Calaradc� Registered Engineer's stamp or N.I.C,E.T I��vel iII (r�in} skamp
�. Equipment cut sheets af m�terials
3. Hydra�uliC c�ICUlati€�ns
4. A 5tate of Colorado contractor registration nurnber
5. Plan� must be submitted by a Registered Fire Prote�tion Contractor
Project 5treet Address: {)fFce Use:
384 Gt�re �Creek ar. 1-12
Project#:
�Number] {Street) {Suite#)
BuildinglComplex Mame:
Villa Valhal{a Buakding Permit#�
Sprink&er Permit#:
Contractor Informatian: Lot#: 61vck# Subdivision:
GQ�,���y. Western States Fire Protection
CompanyAddress: 7026 S. Tucson Way petaifed Description of Wark: Retrofit NFPA13R 2010
�pty_ Centennial S��t�� CO zip�8�d112 spr�nkler system inta buildinc�. Existing 4"
Gontact Name: Jasan Breschu underground.
Contact Phone:
303-928-(��92 (use additional sheei if necessary)
E-Mail Jasan.brachu a�wsf�.us Detar[ed Location of Wark=
Town af Vail Contractor Registration No.: 3�$'�
� Does a Monitored F�re Alarm Exist? Yes 4 } Afa�r�
Cs�ntractor Sig�ature(required} poes a 5prinkler System Exist? Yes{ i �lo{�}
Property Informatian Work Class:
Parce�#: �z101-(3$2-38-001) through 2101-082-38-D12
(For parcel#,conta�t Eagle County Assessors Office at 97[1-328-8640 or New[ ) Addition( } F�emvdel{ } Repair{ }
visit^�vww.eaglecounty.uslpatie} Retro-Fit{�} Other{ )
Tenant Name: ��Itiple (V�II�Vak'h�ll�} Type of Buildinc�:
Mu�ti le Single-Famiiy( j Duplex( } Multi-Farn�ly(�)
Owner Name: P
Commercia!( } Resfa�rrant� } Clther{ )
Complete Valuation for Fire Sprinkler Permit_
Fire Sprinkler$: �3�,Q�Q �ate Received:
fJl-�cb-li3
� �
� � r�^,
��I � J
�
� .. � .� �
� � � � �
� � � � �
$••I �p '� �, O
� � 4 � •~
U �
� i^"1 V
� o ti'' i--�
�L H O ��7' v�-�
INSl1LATIpNMl15T BE ^ �. � •�`7� �~���'}ff(���
. C't�ER PIPIVG. f'� +J t y �
. ��rr n�
,.. ��.- - - _ _ .PIPIhG5Y5TEM V T . � �� �
� ��ti
�' -- .__.. _ _ � ... . ..
�f r.+
� . - -�� _-�_.
� � �� N +�
� �_ - __ � ..�
�, _-. -�1. � � � � C!]
_
,� .
_
w��i�r`�° m s�.m��" I'I x�4r H4 F .�� �- .. :-_:_":�. ... ' . . � � � �
G • $nwPIpY�Rn! �� � _ --r� ..�� � � � • �
.- ..�.a. .w�.,. .m � �E N E�A L N�T E 5 � -- _� _ _� ; , ��,�„�FR � � a
�.. _.....„ - - __ :. ; �� o
. , , �' U
�:F,� , �_ � d _ _���, __ �"
�. THE SCOPE QF W�RK I� TC� RETR�FIT A FIRE SPRIIUKLER SYSTEM PEh� 2�110 `� � -�� �
� ,f. �
71•-++i.
NFPA 13R. .;, : �..�
_ INS�JLkTION � �I,-Y -
,/ � "�' " �
- Y�::..� �. THE SYSTEM WILL BE A WET 5Y5TEM. • �----- ---. '�
�•��� , ��
..-ru,. ' H � � "'-��FIRE SPRINKLER �
ru _- � �
�� � _ _ _siTE �oc�,Tiorv 3, SPRINKLERS ARE SPACED FG�R 16' x 1 fi' Mf�C. THE SYSTEM 15 C�1LCU�LATE� �
'� �-- '� �°� BASED �N THE MQST []EMANDING 4 HEADS FC7R A 0.1 GPMIFT� ❑EI��ITY.
y:..r `Y�.. . � , ��••-� �
"' ' � CAL13tl��+1-IT f.°,IIYIPDRTANT THAT THE INSIJLATION 6E INSTALLEO � 6'+
�� --'-M 4.ALL 5 JFFITS (BY�THE RS} ARE TC] BE LESS THAN 8" I N WIDTH. SPRf[�J�LERS TIGH4 FO THS JOISTS,IN UNHEATED AREAS.ANY SPACES DR r
"�^�•�-'-� ' ° °•"- ��� VOf[15 BETWEEN THE IMSULATION ANO THE J�ISTS GAUSES THE O
- � �1�T REC�LJIRE❑ BELOIN PER hJFPA 13R 2D10 SEC 6.4.6.3.6.1 f�ND NFPR 13R WATER INTHE FIRE SPRINKLER PIPING TO FREEZE.
2010 5EC 6.2.2.1 iFIGLlftE A-4 3.1(ay FR�M N.F.P A.130]
VI�IN ��`� MAP f�JS�JLATION �ETAIL #1 ° o
5. SPRIIVKLERS N�T f�EQUIREG I�J BATHRC�QMS PER �010 NFPA 13R S�EC �.6.2. �' ~
SCALE: N.T.S.
a
�
fi. SPRINKLERS N�T REQUfRED Ihl ���SETS PER 2010 NFPA 13R SEC 6.6.3. �
�
7. THE SY�TEM WILL BE IhJSTALLEQ WITH STEEL PIPE: GROOVED Ea�'�-�L�ilt1 p
((]F� E�LJIVALENT} STEEL PIPE FC)R PIPE LARGER THAN 1'" AND SCHELLJL� 4Q o
PIPE FOR 1" PIPE.
w[�} zsn
IN�LIIRTIONMl1,�,i0C �'i'� 'e'/
8. EXISTING 4" DLICTILE IRC3N UNDERGRC3UN❑ IN BASEMENT LEVEL. °�E�P'P'"G J
-- - - PIPIry�SY$TEM �
_ ._ - _ -_—__- �
___-
..____.- �:��- . J
__.._
9. HANGERS SHALL BE PLACED f�Na SPACED IN ACC�RDA�JCE WITH NFPA 13R _ - . � �
� ,--:��
2010, ❑ETAILS (aN THIS SHEET, A�IQ MA�IUFACTURER'S SPECIFICATIaNS. ' f~ '"r z
. �
�� .
'�"` a ��; - '` � Y;'. ' ` {`�,.- _ . �` _ _ �
' �
. f" �- �- �
r„� - -_ �, - � � P 10. RLL'VtiJIRING �F DEVICES IS BY�3THERS. � -
�'��` � ' ' - - � — .-`. �
-�-� �. .:.x�,: � . . � ,� 11. TENTING AND INSULATIC»J BY C7THERS. _ � _ _ _ ��+��FR��;�,�
�'�' � � - � � :. . z
- __ - � : � .
� � - :�� � , :� � 12. HORN AND STRO�BE BY�THERS. eF,�,� - .. � � -- _
� ��--�: -- - r` _
� � {i°� 1 IN5114API��S � �;,
� �..� .�i.� i . �,, � . � ��1;.-rj ,�.
� � . �#_ �• ' . ,'�.....'"
I�' � ►� +
� �. �,� ��� � �� �' �
� 'e`. T� � - � ypIDSRACEARO�FIOLINE
6 q�� J� - � � '��FIRE SPRINKLER �vSF BE PR�VIOE�FOH
HEAS"O CON'blh;i TkRpllGil
� y f CEILINC. �
� ;�'-�� � •� .� 1 � �.� t i �
- � " - _ CAUTIf1N:IT 13 OMPORTANT THAT THE INSULATIDN BE INSTALLED �r
�� FIGHT TO THE JQI T .IN LINHEATED AREAS,ANY SPACES OR []
� VR]IDS 6ETWEEN THE INSUL4TION AN�THE JOISTS CAUSES TH�E UJ
`..,,` ,'j � � NFATER IN THE FIRf SPRINKLER PIPING TO FREEZE. �
r - - -`' �� �� � i (F4GUREfa-4.3.1(a3 FROM N.F:P.A.13�)
'v � F �
• l�:..,
, ` c
�i".-' :�—�� t� � ,�:�t� • �� � I N S�U LAT I�N D ETA I L #2 �
�
�
�
�ITE 1111'AP m
SCALE: N.T.S.
�
�
0
�
�
w
�
HY�RAULIG SYSTEfi�
This k�uilding is prote�ter�
by a Hydraulically Designed
Autor^atic 5prinhler SystcM_ Hanger nia.q2s
- SAk�NiY SCREW Inverted Top Beam C-Clafnp iBeam)
� FL01N RESULTS! FLQ1N MAR�CH Location I ur�ir�e eEV[�sc r�or_�nn 51aE SAMMY SCREW - ,1
VAIL CDNVER5I�N TEST RE'D1JCT. ������ ,
SideSammyScreew ..�� = 'd a a Q Q Q a
f l n, h
TATIC PRES.SURE 135 1�17.97 � � — Steell-Beamor �
No. of Sprinhlers � " �� ' �� •r�r�ob�i e���o�5t �
4" F E E D T O 4" � f , � � 1
STANDPIPE(EXlSTIt�G) RESIDUAL PRESSURE 130 97.23 Basis of Design �Neaestlnch°� _ �� mN ' { ; s��s�fee„� � " '�' I � F�]R SUBMITTAL
1 Thread �e� ' _- � -
� FLOW 805 ��2.06 �.o��us��v I �r.m{} GF'M�SO.Fi.� + :�, Rad ?� Moda130�Nlichigan - PSI Q�,TE: (}311�12013
°,P 3��� � Top Beam C-Clamp Thread d Ro�ndsdto
2.DLSI[�NLU AHI A[.11 � yi1ly SI�.FT. I ..5� -P�Re ~� Naarestpncha �hfead �...� ; Pra6riM Hde ��9Q��k N� R"d 4 '' , Nearest In�h
4" VfKfhIG Er'�SYF'AC OUT5IDE HDSE 140 �@0 rn�r.Hn�cF SwivelRing Rad '
PIPING FRflM�iJC RISER ASSE4VIBLY sy�i��„n��,�����{ �_ �� f SCALE= N.T.S.
TQ BE FIELD'J�F�1FIE� W(TEST& C1�AIN `',,f�r � ;,:a��
WITH VAIL FIRE i.c,NM uisc;tini�e�� �a�.zs ce�r� —�e s�e�R�� ; ���;,,
{EXISTING��CHEGK � . Nola on Plan:HangeeNum6ar and'A'Qimansoon Swivel Ring � (2.,��� t }
VALVE Tc7 6'E USEQ� f, � i' � THEIBA.E[iF�T�f�E�RI�CR _�i'`"13 PS9 � +
� I , �
� ; _,'
i[7[1GPMA�I]ITII�INAI Hi7RF SiRFFIM . � ��
ALLO'�AfqMCF RE 0'� No[e on Plan.Hanger Num6er an4'A'Dimension Mate on Plan.Man�r FNm�6er and'A Oimension rT
I �_.-:;r-a..
� �
�� �
�� � , HAI�GER DETAILS � �
I � 4"AMES C40� RP �AGKFLC3W � � �
SCALE: N.T.S.
� � � �
---- t-- �--�
BERMA� FP-72L1-lJL PRV �.-.-,.._,.__. l � �
M��
� � �
� �
EXISITI�JG 4'° UNDERGRDUND � � '�j �
�J
- ' West+ern �t�t�s � � �
�
. � i i,,„� �i �,,.�Fi .� i i �
�,,.tem tiaua� Fue Pr t=ni,•i,�-... �
`� �l�`� �`�'(Jt�'�t1+Ui1 �U� ���f,�<<�{�,oa �
.... � �r�n�i4:ler S}�ieno Lu}���ui �
� ��
� � ��� � � SHEET INDEX ;�� �
:;�x�,:���
� CC]VER PAGE I FP�DO ,
R I 5 E R D ETA I L �ASEMENT& LEVEL 1 I FP 01 ,f� ���
_LEWEL 2_AND_LEVEL 3 _FP 02 I
�I
SI�ALE. IV.T..7. LC7�TLEVEL _. FPD3 I �
C�NTRACT N U I'UI B�F�
�S�S'Q 4
LEV���S
�QVER PA�E
���'l,F'l.f
1 OF�
� �
� � r�^,
,y� � J
�
� cV � �
�
� � � � �
:� � [� �
a � � M� �
� p '� �' O
� � .4 'rl
� (7 i-� � �
� ❑ v �
� [� O �' v�-�
� ..-i
r o��V � �`—� � "J�J�
� � ,�•r-�- C.�
❑ v � �i
❑ 0 � "� � �' �
4� `� � c' �
� � � � �
� � � � a
- _ - - - � � C�r �
� I � o
� �
� a������.� EXISTING 4" LJNDERGR�LlND ''-9" � -'� �-- �' � �
/ . �ATH �•I
io �.A7 �
� 7�'
+ '- � � L �
7 s• � KITGHEN � �il �•-s° �- BEC3R�C3M 7r_�� 7,_gu
B�iDg�OM � ��_y. ��y ,f BEDRc7�M ' . �EDRqC7M - � -g� �E�RaC�M �, �
� s• �
� ��-z° ;__ i �- �
/_ �,-?
i T--�
T v , �°-z•cov� LIVING r*� � � ��� Cf • �
U�JIT 1 � - � - �
L1NIT � 1 � � � � r_ �
� @ATH U
a a• . r � 8AT - -
����aon�� ,, B„ � - RISER L[3CAT1[]N r � ` , r � � � � � � �
, 1 { '� r ''� [y r a = � ~
, . II . �
� ! i 7-8112` � q • 7-9' U � � � � H
CLDSET :_± j CLDS. i_, CI.t�S. CLC]S. CLC]S. -- CLDSET a � � � �
. �. 0'`-b"1'- 3'-4��
�•-airz• • ' /� W n u r o
� r r r �
- � $�-Q'' N'-g" r � 6'_5" 2'-1'/z' � 12'-3'/z" � `2` /�� `-1�'/z`" 3- '/z'r o 8'-Q" r a _ LAUN�7f�Y �c � �c �
� LfVING ' - � , - � - r r r � r
r �,_1. r r r�STdRA,GE � ti S7Q ..``�TC� • _� 7'-9' � r� � � �(� �e rn � oa �
r 1 : v ��' �� ENTRY� ` ENTRV �,� ENTRY -- i, r �'_7�� O ui �i � +ci
`n I �'. F'U K FZ M ,'-s• r ��s" �' ��� �
1 1 1 1 1 1 1 T 1 � 1 �,�" � �rr
� ��
, _z-- � 6'-6"r'z' - � =til z
--- -- — 1 w z `° m � �
� � rn � r�'-s �
� � ,,�``� Ro�tr, �°-10°' -- F� 1 J � � � �
ftonm � � �_ _
B EN �tY �{-2°cavE C
1 �
��7'/z� C�WD � ��. �'-�• BATH -� �� �Lco�E� �
/ i1 , � ': I I � �
�
7'-s�� EXISTING 4�� � KITGHEhJ KPTCHEhJ �
,. � ,� RISES HE �ii�r�� F �i�,�iN� r �
��
�LC7C ERS '� _ +� �_5+/N � � � z � � �
� cc�� r�nF���r�icA� � � HALL r � � � w w �
� � ? -9 � .� � i'-11' ; ��_�,. � Z Z� U��?
�
�._ _
� ' ' � �' �
4'-�10" �12'-0" ' �'. � s o 6' r e o . $,-s„ ,- - � � c�n r� g
f r �
r-.
, A' T ►-y UNIT '� � � � `�
11'-1 D'J"' 3'-8'/" �i U I V� I G � �'�*�" 1 43 $ 3'-11"h� � 4'-111'/z' � � � �
�'-o' I � r
�� � N U] UJ U] u�'3
r _ a
__ � � . � ,�l p Z � � � l�i
GGE LDCKEF�� - ��� ���, t9'-3'�'z' 2'-8'/z' � - �- �'� 0 u� ii ii �i
_ p _ �,_O„ 9,_a„ T , — � w w w w
�o ���� -' � ' r� z zfz{ z=�o�iz� _ --� --�EXISTI 4•� STAI�IDPIPE � a Q a a
� . ` L�CA � HERE � � � � �
T � T �
���Z ���2 � �
� �
11'-1!'z 11'-10/z
� � v - �,�, .' '� � OTT�
� '
_. _ �l,� -; 11'-3'/z' _❑'-�!'/" �- 3-
� - � .
cs�
r _°D LUBBY �' $��. _ �
� q m
7'-10' �
1 M..f��BY
: _'3'_�" �J
�� �
; - � � -
- ELEVRTDR
� r � EL�1�A.TnR II � � �
Ci� �, �,s„ C! _ _ O
p �,=�,.z� ; �,
�
� � � �
,
,1
.
,�, �, ��- rz., 7, ,�2„ _7„ LIVING _ �ATH
i"
� ' STC]R
j' 7, �,,COVE �N
• UNI �T � ` � �`
$, 0, � , BEDRDaM pr
.__ F�, � � !' � a a a��a
z�-o•rz� L�.ur�� r
T
� � /1y�� '10'—fi" 7'-0" FC7R SUBMITTAL
�,' � fD r f0 '...i 7'-1 1" _ �l
_ � DATE: 0311�12013
�r� j r. , = ��r4 �i4 ��i� ��r4 �
� 9'-5" 1'-3' = 9`- ' - S�ALE=3116" = 1`-f�
o �
��� �41T ;�iF_hJ �#ALL ENTR,Y� v
- �;�, "v LC)�
_ �
7,-9� 7,_�, • � M�I
- BE�Rd�CJ� r.T�
F U AT N � �7� S T S 1�E �ro���E � --- C�
TYP I CAL
1 �
/ t� �`+J2`-0�'/�� BAT � � �
Thc�rTye,;ll. �'��,hl.l�.�,(I••l � �
f%' ENTFZY _ � � �
r". �•�'� W�:sT�m Stat�,Firc Pr�tGct���«c'��
r � (!�� [�,ry NICFT L�v�l [�I rT�
'� � r ST� ST❑ � �
� � � � Registra�iote n1fl?8�' � Fil
,�'JJ� i'/z - � T � 5prin11�r Sy°stecn L�;ryi�R �
� � ��� i � � �
r P� a,� � '� �
�'-�` � - �]
CL�S CL�S CL�S _ - _ Sagn�e _ . , t,.� ^ � �,� '
BAT - �M� �
�n �n KITCHEN , , , �/J� h�l � �
ao ao 1 la - 1/a � 1/a 1/a ,� /. � l 1--9
; .. •'' I�I � �
6'-3" # 5'-0'/�' `iJ 9'-8" 4'-1" `�l � �
� � � �
,., . = °°
�1 hl IT � �C �'�
r ^ �
i"
BEDRC?C7M �`� BEDRUQlUi �
� BAT - �
#�
$�_a.
G��ITRACT N U I�I B�R
� � �S�S'Q E�
LEV��LS
6AS�MEhJT
BASEIVIENT LE�IEL FIRE PF��C]TECTIO�N PLAN 'IST LEVEL FIRE PR�TECTI�N PLAN �������
S�ALE: 31'I 6'` = 'I'-t� S�CALE: 31'I�6" _ 'I'-�D ��-Q 1
�or�€
� �
� � r�^,
•�y r�- �
�
C.� N � �
� �. � c� �
:� � [� y�
� �-�- QQ M� �-t
, .. �� �� � � � � � �
,
V � � �
, ,'' =v
, � .'
� , 9'-3" , ' ' i' #�
Q� � � v
g,_�,� ��. ,� H O �' v�
� � I ' , /�� '� -' � �}` r, U �-,� .�
BATH BAT f B;E�Ri7�M ' BEQROf7M BEQR(7C7M � AT#=i/ �LC3SET `� � � �,�j
i ,� �� o• -1 a• � / �J �� p � � �i
i, �' - .�- / r/� ..K ^�
i V 1 � ' �./
j �� f Tf%� /� 7'-10"TYPICAL 7'-i0"TYP1GAL � � N � � � � � �
��17Rn�Jh:� BEDRC7f7f111 B�L7RGC�N1 / ��pF2C7U11� '� - . I ' � I ,' /'� �' I � C� � � C%)
C�'J v
J / � U �
:'�i� r�l ��J r�,� �� l! � � � � � � �
. �,'� f� I � � . � � ' �--�
� � 14' 10" ..i� � " �/ � d
i �[
_ � / _ _ � _� ��� 7 1fl' � � �{� J
140�' i � (J
.
_ ,,
� � N LL]
"� T F� "� � `n � H T � ' � ' % / 7 1 �M••f
r � r � � ` r � ,;
i
- - - �
, ao ao , ... � _ "`�
, .. ,
. � . . ,
, �
.:-.
_ �
;
---- -
---� �=- -_� ,•- . - -' ,
-__ _ _-
, , �i
Y_ �,-,o• � _ __. aEO�zao�n �
. .- � -.
_____ �� v��� �. I -
� /� `, Q�
� � _ :. � I t� 1
� �`. � I f ,
' � " 1A
_ _ -
r �11" 2'-8'/z' r � 11'-5'/z' i o3'- /z'D'-4 3'- 12'- /z}r'-2 4'-0° �'-7Y' M1 8'-10" r � 4"-11" - i- '� WID _ _ io 3'-9'/z'� 13-� - 0' � 15'-DYz" --
���2 �
� � HALL 1 r � -
��_� � o I r _ _� - ,�r DRY SA�NA � �`'1❑ -5T'� �
� T j1
%` r .'� 1 ���r E,s�R1'__- ---- -��r ' = l /� 7'-1D"TYPICAL � �, � 7"-1�"TYPICAL � z
� - '' r r �- �
' �"'� '---- /� I � ` � , � '-�-' � L� , i cci rn
„
ST�R,�,G� � �NTRY �_ �•- ; � f� � D r-s so �v c4
,. ...� _ I � . _
� -- 1 �►- ' - i �..' ' f' - _j �'-- / , U
3'-7'/z" ` a
i "���_3� I N4 FIREPLACE /'° i � f•1�-10" �
� LLI LfJ W LLI J
ACGES I ` 17'-5112° � � � � � �
� ' — — —
7°- COVE I_jl 17`-5t12' 7'-7"CQVE
_--- =I- FEED DR4PS � � � � � � °
� , _ �
FRQM ABt]VE i a �` " " "
� - � ,- U N IT 10 �� H��� � - f- � � � � � �
Rvom - KfTC6�'�t� �� 7'�'�'� ,� ���� r r r �°
�•-�v,
�-,7'-�9" i � ��G 11 Y Y Y Y
LIVING i LIVING . `l� ,/� ,� � ' �e rn � co �
i'� _ ', KITCHEGV � = O � +�i �ri �i
REf. REF. io � �/ � I - � N �
� � UNIT5 � � UNl� 9 ; � �-„ �-�,
� � , � �,
Uf�IT � { 1 : �r�
0 T IT . I �� ' i. I 1..J �I] {"J C'] Q �
7�_1 p,. W � �' c�ri �_ �s
4'-1'/" �'-3'/2' �'7" 3'-11'fz' ����ar TrPi��� ,�r�„ I i' � J � � ce �
= s ,,
�
' �� : ,,, : w
/ f , : :
1 �i J
,
,
�
iJUTC3��R DEGK r - 1/ '� �
59 i � �� , LIV,IIV �� 6.
4`-3 + ' '
1x ' '
� 1 z
7'-10'TYPIGAL `J�i-3"� i >' V � I ' ! •c�"-1 Yz` iv � [L
,
' ,
,
/ .
,
,-
,__ � �` i /' ; �`� '� � � / - —
;
' ' [!)
�,_$,. � r: - , i �I , ^' Y I , �
; -
,
` � i I 9-S � ������� �
_ J , �a i � . . /' I I � � �
i' �UTD��R DEGK � � '� / �/ �' J J �jj
� ,
��� ' � ' ; ; '' � _ �; ; QUTDc7QR DECK � Y �
,
;
;, ,,
1 �� ' ' �
T �; , ..I� �, , , ',... ....::� I , ;�" - -
� � �
�
� ___��2' ' � Z � � �
.. - ,. . , `��ry f' / - '1 I I I � � � �
- - - - - " 1 5 9" �I - - 13�-i o i rz�° I � � z � � v'
,• � � 1'/�" IFEED RISES / f � � �
%` � _ = v�i
,/
,
, ,
ti
_
t''C
;
�
_ 1' 7/�' _ / ..
._
z
�'� ' , ,�` , �, :
FR�M 2NQ__LEVEL _ ,� %' � . - � , ; � � � �,
-——— r` --- C--' STAI R ,!
r, LC�€��Y � � ------ _ / / , � w w w `r'
� � � � �
FEED DR�RS DC]UVN FRt]M AiBt]�!E , � - ---__-� /' . / � w J � w
�J 7 ' 0 LL LL LL LL
� 4�-�orz� � ,� / � , � m m m m
~. � ; 1 - �/ w w w w w
ry , ' _ U Q Q Q Q
B�'_o„ - EL TOR ,;'�' /% , / , � EL �R ❑ � � c� �
3'-4/' ; �
� _� - ,,�` 4� a• t1 � ��� �. �
r,�n �., {. _
_ r' ,��ti 1'fz g O T T T
�"° - cn
, .-r�-- ` :
,, ; ,� �. '; m
,- , , ;
/
' ` 71 ' + ;,l-- 74 �
y,.�� �j D-��I/z Jf s�_a� -,
� � ' .
;� ;�' / �.
ST�7RP�GE w � � � �
/ � 7°-6'C�VE ���� � / -
%�� / ��1,���Ca _7'-11" 'LJ I Y� I I f_l , . \ I , ,
� � ' i�� � �� � � c�
�;��I�TQGQ7R QECK ,�' / ;; ,
, , ' ,�,-9. '"_ FEED DR[3PS D�U'11N TCy KITCHEN a o
' r TQ ,o ,`� , �aEC��a��i ,% �SHDI�UN �N 2ND LEVEL] r �n
V N� k C��f� � /� �, I BELC7W gEDRt7aM w
� I._-- _
, ,
� � I �
1 _i-��_10�� 7`-ii° , � i 1� ��a '��z �
� � ' � � �
_ ,
� � � I T
j j � a'-5,�
/ � HALL t 1 `r' ��k - � - 1 T � �
/ ��� `, __ ' " , - UNIT BGR LIIIING - �
l�ITCHEhJ ---. BELOW M � s�� �
` -, 6„ - � �NTRY CLc7 _ � I
/ 1 7,.�p„ � I 14,_�., d _q.
7'-10" ,1 �. 1 �/' � _ 5
�, _i— � -� � f � I � \
,��-�,��� ; ' ' 1 � � 1 I '�' , , , � ; -.��� � a�a�oan�
;- � , , -. „ , ° .
`� � , �� ,�EDf�C]�M / � � 1/a ��_g�� �o L1NAT 7A BEDR��II� � a a���a
� � - 1 lz FEED RISES T BE�aw
��, '' T� 3RQ LEVEL � - � ��-�,� , z�s M�ST F�1�'DRAULICALLY DEMANDINC �o� suaMiTTa�
_,��-,o� _6�-,0� ► , � ��-11��� � � � � `� � ���c�F� -� REfVI�7TE AREA
_�- _ '-7/z' i � -;- ��Q' / �s'-_�". :� �`�' 1'/z 1 7 a3 ���� DATE: 0311�12013
" 1 -_ - - / '� -
� ���� � - -
', �ATFi � � �-ia � _, � i � 15'-6'/z" 11�_1,���
STaR - -r � V�ST � ! � _ ..
� ,•-�o�. ` / �. , ; ' f c� �� r _ . S�ALE=3116" = 1`-f�
� ;�•-1t7° ENTP.'r' ! �--- � ; ,; � r � � � _�,�
� , ��.
'-- ` " F �T�7 STl7 � � � ��[]RQOhlf s�-71rz � � � T
, ' r ' 1'r': 1'f;
� , �'��`j,+ r � �' 1'-4'/z' � , _ "I/a
T � 1 -,r �+ -.f -r • , ' ,� � s�-a trz° t w r 3'-3'/i'l2'-p° g�_Q" �
� � ' � � ` �r�
. ,
„
CL�S �'-5" �� � w CL � � � �� , �: j- s�-¢ , �� � �.. �,�„ o M�I
� � .�, p � �T�
r-1o° , a �
/ � ,
r •LAUIV '��-10° ' .
; , ' ' ' �
� / �-_-- T 104 26�
_ i { . � .� ,, .7�-1'3" ;
16'-2112' . .`: -
_� �-�❑ ��� I /; / � � 1 L�}F F+I
,, . � , �" � - _
•�.,;. ' �"'�� -� ; ��,�-� , . ._. . ��l'CH�� ��� ! f 1 2 1
' r� 0 3
, , 'r �.•' LJ, _
, - .
�
t, 14'-9 .,' , 1�. \
' � -10" . . �
j _71_
; , ,, % : , `T" ' L�il'ING� � 109 IJNIT 7�3 LIVING
, . ,
,�` 264
/ / i� ♦.% ;,, �� � 4-�" I BEL[�1/1f 1.�.�1 �I �
ia�-s�a�� %" , Ttac�it�a� I�S 4���?ik.�UG l'
,. �-+�
; - ' ,'" RE�. � ` '' ' � B H �..�,.� ���u� °u. I 1��,�. i i iJ i� i u; :��J!��' West�rn�ICE �I.e�1�IIlctic�9��_'�, � P--1
/ ..,... T [�
,
,, � UNfT 8C T� , , ,,,_,,, : , �� �����,�ah��ro�q,,
, . - � _
,�, _ � s � �'
�, , , ,, UNIT 8CR LJNIT BC ' �
; _ % 3�_5�� o ; �,` i BEDR�DM BELOW BEDR��M BEL�W 4'-2'/z" 1 ' S�7rt��l:l�x Syst�m La}'��ut �
BE[�f2�C7�,n � � BE�R{�Qh+1 N ,. 4'-3/�' �
� ' -
, , r
, , ;
, , / - � /
, ,
,
, f % /
t � I ,/� f� / / 270 � � �
,�'`� � � i�'� i %" / /i ,: Si i� `'',' � � �
,
,
f '
,
- , �f
- ?'A.T H `�' � '� � �U
9 3" � $=64 'u' / -3112' r� I �, � � �
,l g� . .
.
�
, , �
, .
� i
`.�� - %� — � � l r� �
� ; � / ' c7UTDc]c]R DEC I ' ~ �`"�
�
,� ,;' K � �
, , ,
, , ,
, ;
;'
, , �
, ;��� , . , ,
� � � � :1 ' .��� .'� . -� -�
,
,
,
,
,
,
: i
; 1
' _—. ;
. _.
__ _
_ .
,. , � is � _ .
� � I � �� I � � -� SEE PAGE FP-Q� �!C)R AD[]ITI�NAL N[]DE TAGS �
� Hydr�Glic Infarmation � ��'
FEEQ DRDPS D�]VIIN T�f33 KITCH�N M--�
�SHC�VIIN IN 2h1D LEVEL) �CCIJPANCY CLASSIFICATIUN! Residential �
DENSITY 0.1 DOgpmlffi for 9DOft�(Actual4�Qft2} �
�ND LEVEL FIR� PRC]TE�TI�N F��AN 3RQ► LEVEL FIRE PF��TECTI�N PLAI� T�TALHdSESTREAMS ,oa.Q�
TOTAL HEADS FL�WING 4
SCALE: 3I'I�" = 'I'-� �CA!LE: 31'16" _ '1'-a �-FAC�a� �.s G��ITRACT N U I�B�R
TQTAL WATER REQUIRE�i 207.23 �S�S��
TDTAL PRESSLJRE REQUIRED 8�.543 LEV��S
�F�'d-]N f}
6ASE of RISER {gpm} 2[77.23 &THIRD
gASE of RISER (psi} 86:543 ��—��
SAFETY MARGIN (psi} +13.9Q7 {13,8°�) 3 or�
� �
'�1 �f
•� A �
� � �f
� � � �
� �. � � �
� � � M �
� p '� �' O
� �4 'rl
U i"'r r�'`, �
� � 0 " �
'� H O � v�-�
s� ,--�� � � '."
�
� � �•r-�- C.�
❑ v � �i
� � �-' N �
y � � �, v
+, � � �; rr�
� �
� �c�} o
�� �✓ C{? *�
�1 S"''
,� a
� �' CJ
�
�
Q�
� �
�
�
z
�
D cv r�
U
� �f J
� � �
� � �
SUPRL'Y �EEDING EXISTING 4" UNDERGROrUND " � ~
a �
W �
�
I � �
, � [r rn
$. ,
a �
" � o
AT G -
{N��CC F� S] °r•� T �
Z
W � r�+s
�' �\ � � �
� �� � J �
�r � �
�= QP�N TD g�L�dW AT IC � C7PEN`rt)SELC7IN �
z
�
� SKYLIGHT (F��{ G� S} �
I
i i �
B�DF�C)C7M N -
�
�
SKYLIGFiT :n �'
I �
�
� T Y
iT 1 �
Y 'y, z
BATH _ T - GLOSET �
s._��, � 5°-� �rz�i s�-ra� : y crs
6-6° 1 - _ 7}
in �
� T � - " BATH �, �
��a���c�rnr ' - � SKYLIGHT � �
�t
� "a � "' �oFr � ' �. s•-„�� :'�•.` �, �
_ Rf6��E SKY�LtlGI-CP � 8_�. --S YLIGF�°F-- � 8 -�� . . . � �
T ��a T in . _ . Y ._. _- r
,_ T � �.. , _ ..- � 0 LL
�T - F � � , , ,i , �. THIS VIEV1f' �S F0R N�DDE TA� �I�U�►LIZATIC�N -Y- ~
$,_��� si-�v� � ��-�o� ��-4�iz ��-�� � m
� '– ,��a - � � -a LDFT .1a1r��� SEE FP�� F�C]R 'M�RE DETAIL C3F F�'I�EF� �O�MP�NENTS � �
o-�, g�-„��,. � �
��-���•.• , {7PEN L�FT - � �a �-• .. Cl
(]PEN T� LIVING @ELt]W � _ � N � s�-� irz , J,.=°� � T
- � � UNIT9 �
� � F� � _ �. � � �,.,---' �
�,11'/' o ' ' s•-s•;
- -- � ,r � 5"112"S"112';' . * . �
c]PEN L�FT DECK � � -. = !'�j �
WITH �� s'-o° • . N '"_,
RI�ER ASSEMBLY
GUARDRAILS �SKYLIGHT , "
1/4 �' �
��IT � Q A�-,�• - s�,����HT- I : E�� TING 4" T►4NDPIPE � `
�:.
N ' _ � n OPEN T❑ LIVIh1G BEL�UtI .✓"� ' Q
_ N �
� ,AI T C � � _ U)
`� C�VERAG llNDEFt - ❑ '� w
i � SKYLI+GHT SKYLIGHT c� sy � : �
- ` F 3`'� � � �
� FEEa DR�PS HERE �� y � FEED TC� SYSTEM _ �_-'"
r �, T� KITC�iEFJ - �, , '�
a a �a /
, � ,-'` "�
6'-5" 1 16'-2" 1 3'-1�,�z. -
13'-14112` � . � aa���a
� �_:., FQR SLJBMITTAL
_ '�-�� DATE: 0311�12013
�
❑PEFJ T❑ L�BBY BELDW N S�ALE=3116" = 1`-f�
�
i
t2'-4" f
- EXISTIMG WATER ENTf�Y IN BUILD�Ih�G L"�
�
�
� � �
� �
� �
I'tic�azias A1. L��.sl:l��,ti I:] �
L O r F T L�'�!'E L F I R E P R�T��T I�N P L A N R I S E R N C�D E T�4 G I S C� "�,���m`t��"F'r��r°`"Y`',"`�`' � � �
SCALE: 3!'I�" _ 'I'-0 SCALE: �.T.S. ����T�.����w IzI � rT1
Re:�i�traricm#10"%R?? P�1
� �
���ritflltilzr Systern La���ri� l �
! � � �
ti<<���,ia r ;
�� / rr� � r�..TI..�� `a.�
fj � Y� �
/ �
. � � �
� � �
�
� ��
�
�
�
�
G��ITRACT N U I�I B�R
�S�S'Q E�
LE�E�LS
L�FT
���lJJ`
aor�
# �
�IB�, Hydraulic averview Joka fVuanber:C51810
• Re ort[7escri t�on:Residential
Jot�
c.,,,, .. ., ���,,,�.,
s�a7a
i..x;r;:���;., ' rr..., �rnx
Ylla Valhalla Retrofrt
:.il�b�rx;f Slalu CMif�lirnt i�vxi tintl�
360 Gore Greek Dr
:.ns.:,:.z w-„
Vail,CO 81657
:,u,,,�„_ �x,...,��:.�r�,�,.��„
System
U�rivry ....::i[�I:pp.[iii�r.
U.1QOgpmlft2 90C�ft2(Actual 43Oft�}
�.�:,,���:�,:a�,,:�,�•;�,��,�.�.:.��., ���r:.,�,�����,:
5.8 K-Factcar 25.fi0 at 19.482 104.00
Cir:<r:..:}�Fix Sryixiklia famtlar CN Spxiklax C�ix�ail�yii�xs
394fi' A
4-,;iF�,i,c,wreub., s.yen.rr�vu,man,
8&543 I 107.23
_,�n Lu�:rc;ir.; Iry�-::{urn �,.�i-
r'�207.23 Q 8E,543 +13.907(13.8°Io]
Supplies Cheek Poin4 Gauges
Node Name Flowlaoml Hase Flow{aoml Static[osiY Residuail�ai] Identifee Pressure4osil K-FactorlKl Flov.�[aoml
1 WaterSupply 6fl2.Ofi 1(]0.�0 7Q�.�J7� 97.230
I]�i+moa;\1.i'��:ii.l,:�,i'1':l
G1�"G�[..na StsCzs I�ir��'r�tit�r[iv���i����
NICE'I Level [II
I2e�istrati��n#10?85_'
�p�i�a�l:ler Systen��.a7•+->>�r
�t:3]]:�luC�" ��,��� —
� ��--
�,
�
�51810-Villa Va�halla-FP2-2nd 3rd LeveE.cad Water Supply at lVcsde 1{6Q2.06,106.04,�Oti.97b,97.234}
150
135
, 12�
, 145 Statie Pressure 10D.97
I I
ga az a� 97 230
i ` �
� �� Q- 207.23 with hose streams
�' 75
�
u�
F `-i � �V
� � System demand curve
- � _ r 45
� •i ,i ., 3f1
_ I�, ,�
.
15
Q
�°°d�o soa 75� 960 105� 1200 1350 ��aa
Water flow,gpm
��, C�}M.E.P.CAO,Inc. �;��RutoSPftIN1(�]VR1 C7 v10.0.55.0 3112+2013 5:13 36PM Page 1
'���� Hydraulic Graph Job Number.CS1810
Re ort Descri tion:Residential
Water Supply at Node 1
150
135
120
105
Static Pressure 100.970
602.06 @ 97230
90 107.23 @ 86.543
� i i
20723 with hose streams
.N
Q
� 75
a
a
�
a
60
System demand curve
45
30
15
0
�150 300 450 600 750 900 1050 1200 1350 1500
Water flow,gpm
Hytlraul'ic Graph
Water Supply at Node 1
Sta�ic:Pressure
100.970
Residual:Pressure
97.230 @ 602.06
Available Pressure a�Time of Test
100.450 @ 207.23
svs�em oema�d
86.543 @ 107.23
Sys�em Oemend(Inclutling Hose Allowance at Source)
86.543 @ 207.23
,ML,O M.E.P.CAD,Inc. �,��AutoSPRINKO VR10 v10.0.55.0 3/12/2013 5:13:49PM Page 2
���� Summary Of Outflowing Devices Job Number.CS1810
# Report Description:Residential
Actual Flow Minimum Flow K-Factor Pressure
Device m m K si
Sprinkler 259 27.21 25.60 5.8 22.006
Sprinkler 260 28.21 25.60 5.8 23.662 II
� Sprinkler 264 25.60 25.60 5.8 19.482
Sprinkler 270 26.21 25.60 5.8 20.420
� Most Demanding Sprinkler Data
,Liy�, �O M.E.P.CAD,Inc. +,�,�AutoSPRINKO VR10 v10.0.55.0 3/12/2013 5:13:53PM Page 3
���� Hydraulic Analysis Job Number:CS1810
Report Description:Residential
_Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure
Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary
U stream Total Len th
�•••••Routel•••••
BL 1.05 25.60 9.50 120 0.205457 2'-7'/z" Pf 1.570
264 35'-0" 25.60 5.8 19.482 Sprinkler 5'-0" Pe
109 35'-0" 21.051 T(5'-0") 7'-7'/z" pv
BL 1.48 51.81 9.64 120 0.140694 0'-11" Pf 0.550
109 35'-0" 21.051 3'-0" Pe
103 35'-0" 21.601 E(3'-0") 3'-11" Pv
BL 1.53 51.81 9.04 120 0.120464 3'-4%z" Pf 0.405
103 35'-0" 21.601 Pe
259 35'-0" 22.006 3'-4%z" Pv
BL 1.53 79.02 13.79 120 0263022 2'-1" Pf 2.129
259 35'-0" 27.21 5.8 22.006 Sprinkler 6'-0" Pe
104 35'-0" 24.135 T(6'-0") 8'-1" Pv
BL 1.73 107.23 14.67 120 0.255804 43'-6'/z" Pf 19.328
104 35'-0" 24.135 32'-0" Pe 3.902
74 26'-0" 47.364 PO(8'-0"),T(8'-0"),4E(4'-0") 75'-6'/z' Pv
CM 1.53 107.23 18.71 120 0.462698 0'-11'/z" Pf 3.218
_..._ _._ . _ __
74 26'-0" 47.364 6'-0" Pe
71 26'-0" 50.582 T(6'-0") 6'-11'/z" Pv
CM 1.73 107.23 14.67 120 0.255804 32'-9'/i' Pf 15.548
71 26'-0" 50.582 28'-0" Pe
51 26'-0" 66.131 5E(4'-0"),T(8'-0") 60'-9'/i' Pv
FR 4.03 107.23 2.70 120 0.004159 18'-0" Pf 0.116
51 26'-0" 66.131 10'-0" Pe 7.800
50 8'-0" 74.047 E(10'-0") 28'-0" Pv
CM 4.03 107.23 2.70 120 0.004159 37'-6" Pf 9.613
50 8'-0" 74.047 30'-4'/i' Pe 2.012
31 3'-4'/z' 85.672 E(10'-0"),3fE(6'-9Yz'), 67'-10Ys" Pv
BFP-9.331
CM 4.26 107.23 2.41 120 0.003159 3'-4'/z" Pf 0.118
31 3'-4'/z' 85.672 33'-11'/�' Pe 0.589
30 2'-0" 86.379 fE(8'-11'/z'),PRV(11'-10"), 37'-4" Pv
E 13'-2"
CM 4.22 107.23 2.46 140 0.002487 42'-7" Pf 0.189
30 2'-0" 86.379 33'-5'/z' Pe -0.026
1 2'-1" 86.543 2E(16'-8'/z'),S 76'-0'/i' Pv
100.00 Hose Allowance At Source
1 207.23
g•••••Route 2•••••
BL 1.48 26.21 4,87 120 0.039881 12'-10" Pf 0.632
270 35'-0" 26.21 5.8 20.420 Sprinkler 3'-0" Pe
109 35'-0" 21.051 E(3'-0") 15'-10" Pv
g•••••Route3•••••
BL 1.53 28.21 4.92 120 0.039134 6'-1" Pf 0.472
260 35'-0" 28.21 5.8 23.662 Sprinkler 6'-0" Pe
104 35'-0" 24.135 T(6'-0") 12'-1" Pv
Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier
/ Actual Inside Diameter �4 87 Value Of C 100 130 140 150
� Schedule 40 Steel Pipe Inside Diameter =Factor Multiplying Factor 0.713 1.16 1.33 1.51
�, �O M.E.P.CAD,Inc. ��;��AutoSPRINKO VR10 v10.0.55.0 3/12/2013 5:13:59PM Page 4
���� Hydraulic Analysis Job Number.CS1810
Report Description:Residential
Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure
Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary
U stream Total Len th
Pipe Type Legend Units Legend Fittings Legend
AO Arm-Over Diameter Inch ALV Alarm Valve
BL Branch Line Elevation Foot AngV Angle Valve
CM Cross Main Flow gpm b Bushing
DN Drain Discharge gpm BaIV Ball Valve
DR Drop Velocity fps BFP Backflow Preventer
DY Dynamic Pressure psi BV Butterfly Valve
FM Feed Main Length Foot C Cross Flow Turn 90°
FR Feed Riser Friction Loss psi/Foot cplg Coupling
MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run
OR Outrigger pt Total pressure at a point in a pipe CV Check Valve
RN Riser Nipple pn Normal pressure at a point in a pipe DeIV Deluge Valve
SP Sprig pf Pressure loss due to friction between points DPV Dry Pipe Valve
ST Stand Pipe E 90°Elbow
Pe Pressure due to elevation difference between indicated points
UG Underground pv Velocity pressure at a point in a pipe EE 45°Elbow
Ee1 11Ya Elbow
Ee2 22'/z°Elbow
f Flow Device
fd Flex Drop
FDC Fire Department Connection
fE 90°FireLock(TM)Elbow
fEE 45°FireLock(TM)Elbow
flg Flange
FN Floating Node
fT FireLock(TM)Tee
g Gauge
GIoV Globe Valve
GV Gate Valve
Ho Hose
Hose Hose
HV Hose Valve
Hyd Hydrant
LtE Long Turn Elbow
mecT Mechanical Tee
Noz Nozzle
P1 Pump In
P2 Pump Out
PIV Post Indicating Valve
PO Pipe Outlet
PRV Pressure Reducing Valve
PrV Pressure Relief Valve
red Reducer/Adapter
S Supply
sCV Swing Check Valve
Spr Sprinkler
St Strainer
T Tee Flow Turn 90°
Tr Tee Run
U Union
WirF Wirsbo
WMV Water Meter Valve
Z Cap
�, �O M.E.P.CAD,Inc. ��;��AutoSPRINKO VR10 v10.0.55.0 3/12/2013 5:13:59PM Page 5
v'�e�tern states
Fire Pratection �o.
��ec�� .�� �..' ��c��
Fire Sprinkler System
Material Data Sheets
For
Villa Valhalla Retrofit
360 Gore Creek Dr.
Vail, CO 81657
Prepared by:
Jason Brochu
Project Manager
Designer
Western States Fire Protection Co.
7026 S. Tucson Way
Centennial,CO 80112
Cell: (303)928-0192
Office: (303) 792-0022
Fax: (303) 792-9049
Email:jason.brochu@wsfp.us
WSFP#CS1810
March 12,2013
PRODUCT DATA INDEX
Description Model Manufacturer
I. Sprinkler Heads
1. Residential Pendent&HSW F1Res Reliable
2. Standard Spray Upright&HSW F1FR56 Reliable
IL Valves&Devices
3. 4"Double Check Butterfly Valve RP Backflow Preventer M400 Ames
4. 4"Pressure Reducing Valve 720UL Bermad
5. 4"Zone Control Assembly EasyPac Viking
6. 2"&smaller Ball Valve 722 Victaulic
7. 4"Firelock Check Valve 717 Victaulic
8. 4"x2'/z"x2�/z"Two Way, Single Clapper FDC 5710 Potter
IIL Pipe&Fittings
9. Black Steel Pipe Sch10/Sch40 Allied
10. Black Steel Pipe Dyna/Eddy Allied
11. Eddyflow Steel Pipe Eddyflow Bullmoose
12. Eddythread Steel Pipe Eddythread40 Bullmoose
13. Firelock Grooved Fittings Various Victaulic
14. Firelock Grooved Couplings Various Victaulic
15. Bolted Mechanical Tee Outlets Various Victaulic
16. Reducing Couplings Various Victaulic
17. Welded Outlet Fittings Various Anvil
18. Threaded Cast Iron Reducers Various Anvil
19. Threaded Cast Iron Fittings Various Anvil
IIII. Hanger Assemblies
20. Top Beam C-Clamp Fig. 68 Tolco
21. Wood Pipe Support Various Sammy
22. All Thread Rod Fig. 100 Tolco
23. Hanger Ring Fig. 200 Tolco
Bulletin 176�e�.A
�
� � Model F1
m
Residential Sprinklers for 2 �
Design Density of .10 gpm/ft �
D
Model F1 Res Sprinklers engineered for the lowest flows
to meet the minimum design density of.05 gprn/f�t�
Types: --�. � �
1. F1 Res 49 Pendent "�"��'►-' � ���'re'�
2. F1 Res 49 Recessed Pendent/F 1 � �'� . ��
3. F1 Res 49 Recessed Pendent/FP -
4. F1 Res 49 CCP Pendent
5. F1 Res 58 Pendent F1 Res49,58&76 F1 Res49,58&76
6. F1 Res 58 Recessed Pendent/F1 Recessed Pendent/F1 Recessed Pendent/FP
7. F1 Res 58 Recessed Pendent/FP
8. F1 Res 58 CCP Pendent
9. F1 Res 44 & 58 HSW
10. F1 Res 44 & 58 HSW Recessed HSW/F2 � ����'� ° �<�
' �^$k��°'`.
11. F1 Res 44 SWC
12. F1 Res 76 Pendent ° - ��
13. F1 Res 76 Recessed Pendent/F1 '
14. F1 Res 76 Recessed Pendent/FP
15. F1 Res 76 CCP Pendent F1 Res 49, 58&76 F1 Res 44&58
CCP Pendent Recessed HSW/F2
Listings & Approvals
1. Listed by Underwriters Laboratories Inc. and �
UL Certified for Canada (cULus)
I 2. NYC MEA 258-93-E ' � ""`'�
`,,�,_
UL Listing Category
Residential Automatic Sprinkler
UL Guide Number
VKKW F1 Res 44 SWC
Patents
US Patent No. 6,516,893 applies to the
Model F1 Res 49 & 58 Pendent Sprinklers
Product Description Technical Data:
Model F1 Res Pendent sprinklers (Figs. 1, 2, 3 & 4) • Thermal Sensor: Nominal 3mm glass-bulb
combine excellent durability, high sensitivity glass-bulb • Sprinkler Frame : Brass Casting
and low profile decorative design. • Sprinklers' Pressure Rating : 175 psi
The 3mm glass-bulb pendent sprinklers permit the Factory Hydrostatically Tested to 500 psi
efficient use of residential water supplies for sprinkler • Thread Size: '/2" NPT(R1/2)
coverage in residential fire protection design. • K�actor.4.9(Acival)-F1 Res 49 Pender�t Spnn4der
The low flow F1 Res sprinklers are specially 5.8(F�h.ial)-F1 Res58Pendent&HSWSpnnkler
engineered for fast thermal response to meet the 7.6(Actual)-F1 Res 76 Pendent Sprinkler
sensitive fire protection application needs of the latest 4.4(Actual)-F1 Res 44 HSW Sprinkler i
residential market standards (UL 1626 Standard *). • Densiiy: Minimum 0.10 gpm/ft2
Upon fire conditions, rising heat causes a sprinkler's
heat-sensitive glass-bulb to shatter, releasing the
waterway for water flow onto the deflector, evenly
distributing the discharged water to control a fire.
* Effective date 7/12/02 I
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application
Model F1 Res Sprinklers are used for Residential Fire Example No. 1
Protection according to UL 1626 Standard*. Be sure Room Size= 12 ft x 20 ft (3.6 m x 6.1 m)
that orifice size, temperature rating, deflector style and Coverage Area= 12 x 20 = 240 ft2(22.3 m2)
sprinkler type are in accordance with the latest Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm
published standards of The National Fire Protection Using an F1 Res 49 Pendent Sprinkler, K=4.9
Association or the approving authority having Pressure= (24/4.9)2 = 24 psi (1.65 bar)
jurisdiction. The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m)
When using F1 Residential Sprinklers for systems covera2qe area using the baseline density of 0.05
design to NFPA 13D or NFPA 13R, use listed area of gpm/ft will be 20 gpm C 16.7 psi (75.7 L/min C� 1.14
coverage and minimum flow and pressure requirements bar). Therefore,the minimum flow required is 24 gpm C�
shown in Bulletin 135. 24 psi (90.8 L/min @ 1.65 bar).
For systems designed to NFPA 13, use information in
this bulletin.The number of design sprinklers shall be the Example No. 2
most hydraulically demanding sprinklers as required by Room Size- 8 ft x 20 ft (2.4 m x 6.1 m)
NFPA 13. Flows and pressures can not be below the - 2 2
baseline flows and pressurers. Coverage Area= 8 2 20 = 160 ft (14.9 m )
NFPA 13 Flow @ 0.10 gpm/ft density= 160 x 0.10 = 16 gpm
Using an F1 Res 49 Pendent Sprinkler, K=4.9
For residential sprinkler systems designed to NFPA 13, Pressure- (16/4.9)2 = 10.7 psi (0.74 bar)
a minimum density of 0.1 gpm/ft must be provided over The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m)
the "design area" that includes the four(4) hydraulically covera2ge area using the baseline density of 0.05
most demanding sprinklers for the actual coverage gpm/ft will be 20 gpm C 16.7 psi (75.7 L/min C 1.14
areas being protected by the 4 sprinklers. The minimum bar). Therefore,the minimum flow required is 20 gpm @
required discharge from each of the four most 16.7 psi (75,7 L/min @ 1.14 bar).
hydraulically demanding sprinklers shall be the �reater
of the following:
1.The flow rates given in the Reliable Residential Example No. 3
Sprinkler Technical Bulletins referenced in Table A Room Size= 10 ft x 16 ft (3.0 m x 4.91 m)
for NFPA 13D and 13R as a function of temperature Coverage Area= 10 x 16 = 160 ft2(14.9 m2)
rating and maximum allowable coverage area (for Flow C 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm
actual coverage areas less than or between those Using an F1 Res 76 Pendent Sprinkler, K=7.6
indicated in the respective technical bulletin, it is The baseline flow for a 16 ft x 16 ft coverage area is 21
required to use the minimum required flow for the gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the
next largest coverage area); or minimum flow and pressure is 21 gpm @ 7.6 psi (79.5
2.A minimum discharge density of 0.1 gpm/ft2 L/min @ 0.52 bar).
applied over the"design area"consisting of the four
most hydraulically demanding sprinklers for the Example No. 4
actual coverage areas being protected by the four Room Size- 14 ft x 18 ft (4.3 m x 5.5 m)
sprinklers. The maximum dimension of the actual Coverage Area- 14 x 18 - 252 ft2(23.6 m2)
coverage area cannot be any greater than the 2
maximum coverage area indicated in the technical Flow @ 0.10 gpm/ft density= 252 x 0.10 = 25.2 gpm
bulletins referenced in Table A. (94.6 L/min)
Design Note: Using the AS - S x L method to Using an F1 Res 76 Pendent Sprinkler, K=7.6
determine the sprinkler protection area of coverag Pressure= (252/7.6) = 11 psi (0.76 bar)
in accordance with NFPA 13, apply the 0.1 gpm/ft� The baseline flow and pressure of an 18 ft x 18 ft
density to this area to determine the minimum coverage area is 21 gpm @ 7.6 psi (79.5 L/min C� 0.52
required flow. Compare this flow to the minimum bar). Therefore, the minimum flow and pressure is 25.2
0.05 gpm/ft2 cULus Listed flow for the appropriate gpm @ 11 psi (94.6 L/min C� 0.76 bar).
coverage area in the technical bulletin for the
specificresidentialsprinkler. Iftheflowstatedinthe In general residential sprinklers re uire
technical bulletin is less than the calculated 0.1 flows and pressures as listed for�.05
gpm/ft2 density flow required, the .1 d�sity flow densities to achieve the proper spray pattern
must then be used in the equation Q=KJP, solving so the flows and pressures at 0.05 density are
for P, to establish the minimum required pressure the baseline flows and ressures. Flows and
using the sprinkler K-factor. Note: In many cases pressures below the lis�ed 0.05 density shall
the listed flow of individual residential sprinklers� not be used.
may exceed the required minimum 0.05 gpm/ft
density. Reliable has available residential sprinklers
with larger K-factors (K=5.8 and K=7.6) that will
provide lower pressure demands for 0.1 gpm/ft2
densities in NFPA 13 residential applications.
2.
Installation
Models F1 Res sprinklers are to be installed as use only the Model GFR2 Sprinkler wrench. Use of
shown. Model F1, F2 and FP Escutcheons, illustrated wrenches other than those specified may damage
herewith,are the only recessed escutcheons to be used these sprinklers.
with Model F1 Res sprinklers. Use of any other Note:A`leak tight"sprinkler joint can be obtained with
recessed escutcheon will void all approvals and the following torque:
warranties. For installing Model F1 Res Pendent • 3/4" NPT (R3/4)— 14-20 ft-Ibs (19 - 27.1 N-m)
sprinklers use only the Model D sprinkler Wrench; for • 1/2" NPT (R1/2)—8-18 ft-Ibs (10.8—24.4 N-m)
installing Models F1 Res Recessed Pendent, CCP Do not tighten sprinklers over maximum
sprinklers use only the Model GFR2 sprinkler wrench; recommended torque. It may cause leakage or
for installing Model F1 Res recessed HSW sprinklers impairment of the sprinklers.
• Model F1 Res 49, 58 & 76
• Model F1 Res 49, 58 & 76 Pendent Recessed Pendent/ F1/F2
_ ,�
IF - =
.��� ---t---��
���y� f � .
. ��F
� ` � �` � �.� �
� �-�
�
.�`�:- f ��� -.
�� ���4�, -
4�_4i ��� � ��v, . . � n�i
—� `_��.�
, �;
F1 escutcheon, /" (19mm) adjustment
Note: See escutcheon table for dimensions.
z,i4-�.�o��o�_
�5�zmm�
� � � 1 15�16"'Dla.
(J9.2mm]
�I= � \I'
_ � __ / i��
— �— — � �I_:- �_
I � t I �9"X I/2"RFOUCFF
I NRN COLWR UIJIIL I
T�GHi AG//NST SPRWKLER
WRENCN BO55 � 'I �
FACE QF FITTING TO
� CE2ING DIMENSION:
�p��j� s/i 6—�5/�s(F>EscurcHFON)
��� 3/>o—>r/>6(vz escurc,vEON�
O�d� ao✓usrMeNr ���G� /.
�;
� �
i ��e..
[3 em„�)
q,
I
I
)35FG03 i35P'co2,a z z�/sz°oia.
[�z 2m,n]
Fig. 1 Fig. 2
3.
Technical Data: F1 Res 49 Pendent and Recessed Pendent
Escutcheon*, F1 or F2, Data:
Nominal Sprinlder Max. M�• q�ual Sprinlder Adjustment °�q�° Face of fitting to
Thread Orifice Temp. p�u� Ambierrt K Length Ty� Inch(mm) Inch(mm) �iling
Size Inch Ratin �i T� • Inch Inch mm
Factor
(mm) �F �C (bar) �F �C (mm) 3 Min.=3/„ (19.1) 3 ,5
F1 /a�19.0) /e- /,s�Q.7-2a.0)
/"NPT , 155 68 100 38 Max.=1/"�38.1�
,
�R%) /6 (11) 175 79 175(12) 150 66 4.9 2.25(57) F2 %(12.7) Min.=,�;6°(23.8) / _,y (4.7-17.4)
. Max.=liz"(38.1) ,6 ,s
*Note: Escutcheons F1 or F2 may be used with
Model F1 Res 49&58 Recessed Pendent Sprinkler
**Baseline flows and pressures for 0.05 density
Deflector-to-ceiling *Deflector-to-ceiling
Maximum 1" (25mm)to 4"(100mm) Ma�cimum 4" (100mm)to 8" (203mm)
Max.Sprinkler Sprinkler Max.Sprinkler Sprinkler
Flow Pressure Flow Pressure
Spacing m L m si bar ldentification Spacing m L m si bar ldentification
ft m gp � p � p � � Number SIN ft m gp � p � p � � Number SIN
I 12 x 12(3.6x3.6) 13(49) 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4 (0.65)
I 14 x 14(4.3x4.3) 13(49� 7.0 0.48)_ 14 x 14(4.3x4.3) 16(60.5) 10.6(0J3)
16 x 16(4.9x4.9) 13(49) 7.0(0.48) R3516 16 x 16(4.9x4.9) 17(64.3) 12.0(0.83) R3516
I 18 x 18(5.5x5.5) 17(64.3) 12.0(0.83) 18 x 18(5.5x5.5) 19(72) _ 15.0(1.0)_
�20 x 20(6.1x6.1) 20(75.7) 16.7(1.14) 20 x 20(6.1x6.1) 22(83.2) 20.2(1.4)
*Note: The F1 Res 49 pendent and recessed pendent
residential sprinklers can be installed per NFPA 13 in
beamed ceilings meeting the following criteria:
1. Maximum beam depth = 7" (178mm)
2. Beam spacing at or greater than 7.5 ft.(2.3m)on center.
Technical Data: F1 Res 58 Pendent and Recessed Pendent
Nominal Sprinkler Max. M�• Sprinkler
Thread Orifice Temp. Pressure Ambient K Length
Size Inch Rating psi Temp. Factor Inch
(mm) �F �� (bar) �F �� (mm)
'/z'NPT /���13) 155 68 175(12) 100 38 5.8 � 2.25(57)
(RYz) 175 79 150 66
**Baseline flows and pressures for 0.05 density
Max.Sprinkler Ceiling-to- Sprinkler
Flow Pressure
Spacing Deflector ldent'rfication
ft m 9pm(Lpm) psi(bar) Inch mm Number SIN
12 x 12(3.6x3.6) 16(61) 7.6(0.53) I
14 x 14(4.3x4.3) 16(61) 7.6(0.53) I
16 x 16(4.9x4.9) 16(61) 7.6(0.53) �25- 00) R3513
18 x 18(5.5x5.5) I 19(72) 10.8(0.75)
20 x 20(6.1x6.1) � 22(83.3) 14.4(1.0)
**Calculate for a.10 density but in no case
go below the baseline flows & pressures
4.
Technical Data: F1 Res 76 Pendent and Recessed Pendent
Nominal �' Max. � �
Thread Orifice T� Pres�ne � K Leriglh
Size Inch psi T Factior trx:h
(mm) �F �� (bar) �F �� (mm)
3 Face of fitting to
/"NPT ,�32��13.5) 155 68 175(12) 100 38 �6 2.25(57) T Adjustmerrt "A" ceilin
(R/,) 175 79 150 66 Y� Inch(mm) Inch(mm) g
Inch(mm1
*Baseline flows and pressures for 0.05 density �� ��19�0> MaX-?�°�38�.1� 3i6-'is�4�'-z4.o�
F2 %(12J) Min.='%6"(23.8) %s-'%s(4.7-17.4)
Max. Sprinkler Sprinkler ,Max.=1y°(38.1)
Flow Pressure
Spacing Identification
ft m 9pm(Lpm) psi(bar) Number SIN
12 x 12(3.6x3.6) _ 21 7.6(0.53�
14 x 14(4.3x4.3) 21 7.6(0.53)
16 x 16(4.9x4.9) 21 7.6(0.53) R7618 "Calculate for a .10 density but in no case
18 x 18(5.5x5.5) 21 7.6(0.53) go below the baseline flows & pressures
I 20 x 20(6.1 x6.1) 23 _ 9.2(0.63)
• Model F1 Res 49, 58 & 76 • Model F1 Res 49, 58 & 76
CCP Pendent Recessed Pendent/ FP
��
i 'a �
�
�' ��Y�'c����''�i.-� ��4�Y °�I,
� ��, � �
'; ' -
� —
FP push-on/thread-off
escutcheon
2 5/8°(66Jmm� 0/!J. 2 5/a"aia.[ae.�mmJ
HOLE IN CEILING
% Jr/76 nlF�. l'��L� 1/�l 1����L�I�G
�Sfj.7�"pmJ 2 5/16"'OIA.
GUP ---�'�—� [58.7mmJ
___-.-,_}--,-:-:-i /
CUP
,,;_.�....�___.._____s__', I � �
`---..___...i........._....-r � 1'x 1/2" REDUCER I____=_—�
i � =_====�-�
CL�P ' \ � I I I"X I/2'REDUCER
` ----I--__—
�--� �—
CELIAiG �_��_�
.� �d� , 7 7/a°[j7_Smm] �V /
��r Max FacE oF FirnNC � i /
ro FACE oF cEiuNC � �
�� ����� %L� DIMENSION
� L J
A„
CfILING
�
B
C�VFR fl(�✓USTMEI�T {'�E�ri�-/j � - W l 1�7��(39.Imm]MAX.
j ���r� FACE OF FIT7WC
( - 70 FACE OF CEILING
I I\� OIMENSION
�\�� �
3 5�7 6° DIA.
735FG0=�C [8�.�mm] �
l/2"(13mm�MAX. �
F 1 R E S 4 9� 5 8 & 7 6 C C P P E N D, FP AOJUSTMEN7 A
�
Fig. 3 Fig. 4
NOTE: The F1 Res 76 will use a 1"X 3�4� reducer.
5.
Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/ FP
- CCP Options Data:
Nominal ��d�' � Max. � Spri�lder "A" "B"
Thread Orifice Temp. �� p�re Ambierrt K �� Cover Adjustment CCP Height
S'¢e Inch � � psi T�p. F�tor Inch Inch mm Inch mm
(mm) oF � o� oF o� (bar) � oF � o� (mm) %(1z.�) '%(24)
1iz��NPT , ,� � z.z5 %(4.�) � %(19)
�R,�?� /16 (11) 155 68 135 57 175(12) 100 38 4.9 �57�
*Baseline flows and pressures for 0.05 density FP Data "A":
Max.Sprinkler Sprinlder FP Position A
Flow Pressure Inch mm
Spacing m L m si bar �dent'rfication � � -
ft m gp � p � p � � Number SIN Max. Recessed %6(11)
12 x 12�3.6x3.6) 13(49� 7.0(0.48) Min. Recessed 'sj16(24)
14 x 14(4.3x4.3) 13(49) 7.0(0.48) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not
16 x 16(4.9x4.9) 14(53) 8.2(0.56) R3516 suitable for installation in ceilings which have
18 x 18(5.5x5.5) 18(68.1) 13.5(0.93) positive pressure in the space above.
20 x 20(6.1x6.1) 20(75.7) 16.7(1.14)
Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP
Nominal ��' � Max � �Wer
Thread Orifice T� �� Pres�re a�►� K Ler�gth
Si� Inch ��J psi T� Factior hich
(mm) oF o� oF o� (bar) oF o� ��)
'�R�2� Y2"(13) 155 68 135 57 175(12) 100 38 5.8 2.25(57)
*Baseline flows and pressures for 0.05 density
Max.Sprinkler Flow pressure Sprinkler
Spacing Identification
ft m 9pm(Lpm) psi(bar) Number SIN
12 x 12(3.6x3.6) 16(61) 7.6(0.53)
14 x 14(4.3x4.3) 16(61) 7.6(0.53)
16 x 16(4.9x4.9) 16(61) 7.6(0.53) R3513
18 x 18(5.5x5.5) 19(72) 10.8(0.75)
20 x 20(6.1x6.1) 22(83.3) 14.4(1.0)
Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP
Nominal ��►' �� Max. � �rnlda�
Thread Orifice T� yT�, � � F�tK or h�di
Size Inch �xJ �� psi
�mm) . oF oC oF oC � oF oC ���
3/n"NPT �%z" 155 68 135 57 175(12) 100 38 �6 2.25
(R3/4) (13.5) 175 79 150 66 (57)
*Baseline flows and pressures for 0.05 density
Max.Sprinkler Sprinkler
Flow Pressure
Spacing Identification
ft m 9pm(Lpm) psi(bar) Number SIN
12 x 12(3.6x3.6) 21 7.6(0.53)
14 x 14(4.3x4.3) 21 7.6(0.53)
16 x 16(4.9x4.9) 21 7.6(0.53) R7618 *Calculate for a .10 density but in no case
18 x 18(5.5x5.5) 22 8.4(0.58)
go below the baseline flows & pressures
20 x 20(6.1 x6.1) 25 10.8(0.74)
6.
• Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58
Recessed HSW/F2
���_...,, r.
z :a
�_� �+ r g•
-�' ��1
I�ir ,�,, .
,� � � -��u 1 , �' �
a �S
:�; �. .'�' '���� �. `�,
, ,.- �
�� �;�� ,� },,
F2 escutcheon, y" (13mm)
adjustment
Technical Data: F1 Res 44 HSW & HSW/F2
Escutcheon, F2, Data:
Thread Orifice I T�p�� pres�,re Ambient K �� Ty� Adjustment Fac�o aitting
T� � � Inch(mm) Inch mm
S�e Inch � psi
(mm) °F �C (bar) °F °C (mm) Fz %_(13) ls_"/,6_(n.�-1�.4>
'/z"NPT ����10� 155 68 175(12) 100 38 4.4 2.45(62)
(Rh) 175 , 79 150 66
*Baseline flows and pressures for 0.05 density
Max.Sprinkler ��li g'-to- Sprinkler Temp. Flow p�ssure Sprinlder
Spacing peflector Rating Jpm psi(bar) Identification
ft(m) Inch mm F( C) (Lpm) Number(SIN)
12 x 12(3.6x3.6) 155(68) 175(79) 12(45.4) 7.5(0.52)
14 x 14(4.3x4.3) 155(68) 175(79) 14(53.0) 10.2(0.71)
16 x 16(4.9x4.9) 4_g 155(68) 175(79) 16(60.6) 13.3(0.92)
16 x 18(4.9x5.5) (101-152) 155(68) 175(79� 18(68.1) 16.8(1.16)
18 x 18(5.5x5.5) 155(68) 175(79) 19(72.0) 18.7(1.29)
16 x 20(4.9x6.1) � 155(68) 175(79) 23(87.1) 27.4(1.89) R3531
I 12 x 12(3.6x3.6) 155(68) 175(79) 14(53.0) 10.2(0.71)
14 x 14(4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92)
� 16 x 16(4.9x4.9) 6-12 155(68) 175(79) 17(64.4) 15.0(1.04)
(152-305)
16 x 18(4.9x5.5) 155�68) � 175(79) 20(75.7� 20.7(1.43�
I 16 x 20(4,9x6.1) � 155(68) 175(79) 23(87.1) 27.4(1.89)
*Calculate for a .10 density but in no case
go below the baseline flows & pressures
7.
• Model F1 Res 44 SWC
�
..� .�*, 4„to 12„
- [701 60mm 70
���� I 7/4"(37.75mm)Mox�mum 304.80mm]
�g -"�. Face 01 Fitting
�•�� ����p,.� 5� � To Woll DimenSion PUSH ON COVER, THEN
' ^� TURN TO ADJUST UNTIL
� '`�'°�"' TIGHT AGAINST WALL.
...��� �. • �`'�� ,..; 1••X i/2' Reducer �.
u!
� Recommended �1uu7 `�
Woll Hole 2 5/16" � �
a s/a• (ss.�a,,,,�,1��;;! ' - - -�--
(66.68mmJ DIO. 3 5/16"
i , (84.14mmJ
Dio. � -
� D�a.
i r�l
I
TURN COLLAR UNTIL
TIGNT AGAINST SPRINKLER � z��32..
WRfNCH BOSS. `J
(42.07mm)
135FGOl -� 1�2���12.70mm�
Adjustment
F1 RES 44 SWC
Fig. 5
Technical Data: F1 Res 44 SWC
Nominal ��' �.T� Max � �r'rilder
Thread Orifice T� � Pres�re ,q��T� K LengUi
Sme Inch � psi FacUon c�h
(mm) � � � � (bar) � � (mm)
���RN�T �"(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62)
*Baseline flows and pressures for 0.05 density
Mau.Sprinkler '�' Flow Sprinkler
Spacing �iling-to- gpm Pressure Identification
ft(m) �flector ��pm� psi(bar) Number(SIN)
Inch mm
12 x 12(3.6x3.6) 13(49.2) 8.7(0.60)
14 x 14 4.3x4.3) 14 53.0 10.2 0.71
16 x 16(4.9x4.9) (101-52) 17(64.3) 15.0�1.1)
16 x 18(4.9x5.5) 19(71.8) 18.7(1.13)
16 x 20(4.9x6.1) 23(87.1) 27.4(1.89) R3531
12 x 12(3.6x3.6) 14(52.9) 10.2(0.71)
14 x 14(4.3x4.3) 6-12 15(56.7) 11.7(0.81)
16 x 16(4.9x4.9 (152-305) 18(68.1) 16.8(1.16)
16 x 18(4.9x5.5) 20(75.6) 20.7(1.43)
*Calculate for a .10 density but in no case
go below the baseline flows & pressures
8.
Technical Data: F1 Res 58 HSW & HSW/F2
Escutcheon, F2, Data:
Nominal Sprinkler Max. M�• Sprinkler Adjustment Face of Fitting
Thread Orfice Temp. p�su� Ambient K Length T� Inch mm to wall
Size Inch Ratin psi Tem . Factor Inch � � Inch mm
(mm) �F �C (bar) �F �C (mm) F2 %(13) %-"/,6(4.�-1�.4)
'/z'NPT /���13) 155 68 175(12) 100 38 5.8 2.45(62)
(R/z) 175 79 150 66
*Baseline flows and pressures for 0.05 density
<<A„
Mau.Sprinkler Sprinkler Temp. Flow Sprinkler
Spacing �iling-to- Rating gpm P�SU� Identification
ft(m) �flector �F(°C) (Lpm) psi(bar) Number(SIN)
Inch mm
12 x 12(3.6x3.6) 155(68) 175(79) 16(60.6) 7.6(0.53)
14 x 14(4.3x4.3) 155(68) 175(79) 18(68.2) 9.7(0.67)
16 x 16(4.9x4.9) (101-1�52) 155(68) 175(79) 21 (79.5) 13.2(0.91)
16 x 18(4.9x5.5) 155(68) 175(79) 25(94.7) 18.6(1.28)
16 x 20(4.9x6.1) 155(68) 175(79) 29(109.8) 25(1.73) R3533
12 x 12(3.6x3.6) 155(68) 175(79) 22(83.3) 14.4(1.0)
14 x 14(4.3x4.3) 6_12 155(68) 175(79) 22(83.3) 14.4(1.0)
16 x 16(4.9x4.9) (152-305) 155(68) 175 79 26 98.4 20.1 (1.39
16 x 18(4.9x5.5) 155(68) I 175(79) 31 (117.4) 28.6(1.97)
*Calculate for a .10 density but in no case
go below the baseline flows & pressures
Finishes�'�
Standard Finishes Ordering Information
Specify:
S rinkler F1, F2, FP Escutcheons 1. Sprinkler Model
Bronze Brass
Chrome Plated Bright Chrome Plated 2. Sprinkler Type
White Polyester Coated White Painted 3. Temperature Rating
Special Application Finishes 4. Sprinkler Finish
S rinkler Fi, F2, Escutcheons
Bright Brass Bright Brass 5. Escutcheon Finish
Black Plated Black Plated
Black Paint Black Paint
Off White Off White
Satin Chrome Satin Chrome
�"Other finishes and colors are available on special order.
Consult factory for details.
9.
Maintenance
Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers Model F1 Res 49 & 58 Recessed Pendent/F1,
should be inspected quarterly, and the sprinkler system Model F1 Res 49 & 58 Recessed Pendent/F2,
maintained in accordance with NFPA 25, 13, 13D, and Model F1 Res 49 & 58 Recessed Pendent/FP
13R. Do not clean sprinkler with soap and water,Ammonia Sprinklers shall be [cULus Listed] [New York Ciry MEA
or any other cleaning fluids. Remove dust by using a soft Approved (258-93-E)] low flow residential recessed
brush or gentle vacuuming. Remove any sprinkler which pendent sprinklers engine red to provide a minimum
has been painted(other than factory applied)or damaged design densiry of 0.10 gpm/ft�over the listed coverage area.
in any way. A stock of spare sprinklers should be Listed flows as specified by the manufacturer's technical
maintained to allow quick replacement of damaged or data sheets are to be used. Residential sprinklers shall be
operated sprinklers. Prior to installation, sprinklers should installed in conformance with the manufacturer's installation
remain in the original cartons and packaging until used. guidelines and the applicable installation standard. Where
This will minimize the potential for damage to sprinklers that pendent residential sprinklers are installed under sloped
could cause improper operation or non-operation. ceilings having a pitch of up to [4/12] [8/12], the sprinklers
shall be listed for such use. Deflector-to-ceiling distance
listing shall be 1" to 8" maximum. Sprinkler frame and
Model F1 RES 49 Residential deflector shall be of bronze frame construction having a'/2"
Sprinkler Specifications NPT thread. Water seal assembly shall consist of a
Teflon-coated Belleville spring washer and top-loaded
extruded cup with 3 mm glass bulb containing no plastic
Model F1 Res 49 & 58 Pendent parts, and having a temperature rating of [155°F (68°C)]
Sprinklers shall be [cULus Listed] [New York City MEA L1�5°F(79°C)]. Sprinklers shall have a nominal K-factor of
Approved (258-93-E)] low flow residential pendent 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White
sprinklers engineered to provide a minimum design Polyester] [Special finish—specify]. Recessed escutcheon
I density of 0.10 gpm/ft2 over the listed coverage area. assembly shall be a steel, two-piece escutcheon [with '/2°
Listed flows as specified by the manufacturer's technical adjustment(Model F2)] [with 3/4" adjustment(Model F1)] [of
data sheets are to be used. Residential sprinklers shall be push-on and thread off design with '/2" adjustment (Model
installed in conformance with the manufacturer's FP)]. Standard finish shall be [brass][bright chrome] [white
installation guidelines and the applicable installation painted]. Residential recessed pendent sprinklers shall be
standard. Where pendent residential sprinklers are Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1]
installed under sloped ceilings having a pitch of up to[4/12] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1
[8/12], the sprinklers shall be listed for such use. Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513
Deflector-to-ceiling distance listing shall be 1" to 8" (Bulletin 135).
maximum.Sprinkler frame and deflector shall be of bronze Model F1 Res 49&58 CCP Pendent(Concealed)
frame construction having a '/2" NPT thread. Water seal Sprinklers shall be[cULus Listed] [New York City MEA
assembly shall consist of a Teflon-coated Belleville spring A roved 258-93-E low flow residential concealed
washer and top-loaded extruded cup with 3 mm glass bulb sprp klers engineered] to provide a minimum design
containing no plastic parts, and having a temperature density of 0.10 gpm/ft2 over the listed coverage area. I
rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall Listed flows as specified by the manufacturer's technical
have a nominal K-factor of 4.9 & 5.8. Standard finish: data sheets are to be used. Residential sprinklers shall
[Bronze][Chrome-plated][White Polyester][Special finish— be installed in conformance with the manufacturer's
specify]. Residential pendent sprinklers shall be Reliable installation guidelines and the applicable installation
Model F1 Res 49&58,SIN R3516&R3513(Bulletin 135). standard. Where pendent residential sprinklers are
installed under sloped ceilings having a pitch of up to
[4/12] [8/12], the sprinklers shall be listed for such use.
Sprinkler frame and deflector shall be of bronze frame
construction having a '/2" NPT thread. Water seal
assembly shall consist of a Teflon-coated Belleville
spring washer and top-loaded extruded cup with 3 mm
glass bulb containing no plastic parts, and having a
temperature rating of 155°F (68°C). Cover plate
assembly shall consist of a brass cover plate and copper
alloy retainer flange. Method of attaching the cover plate
to the sprinkler cup shall be a push-on and thread-off
design allowing a '/2" cover plate adjustment. Cover
plate temperature rating shall be 135°F(57°C). A plastic
protective cap shall be provided and factory installed
inside the sprinkler cup to protect the sprinkler from
damage, which could occur during construction before
the cover plate is installed. Standard cover plate finish:
[White] [Custom Color— specify]. ]. Concealed pendent
sprinklers shall be Reliable Model F1 Res 49 & 58 CCP,
SIN R3516 & R3513 (Bulletin 135).
10.
Model F1 Res 44 & 58 Horizontal Sidewall Model F1 Res 76 Recessed PendentlFl,
Sprinkler Model F1 Res 76 Recessed Pendent/F2,
Sprinklers shall be [cULus Listed] [New York City MEA Model F1 Res 76 Recessed Pendent/FP
Approved (258-93-E)] low flow residential horizontal Sprinklers shall be [cULus Listed] low flow residential
sidewall sprinklers engineered to provide a minimum recessed pendent sprinklers engineere�d to provide a
I design density of 0.10 gpm/ft2 over the listed coverage minimum design density of 0.10 gpm/ft over the listed I
area. Listed flows as specified by the manufacturer's coverage area. Listed flows as specified by the
technical data sheets are to be used. Residential manufacturer's technical data sheets are to be used.
sprinklers shall be installed in conformance with the Residential sprinklers shall be installed in conformance
manufacturer's installation guidelines and the applicable with the manufacturer's installation guidelines and the
installation standard. Where horizontal sidewall applicable installation standard. Sprinkler frame and
residential sprinklers are installed under sloped ceilings deflector shall be of bronze frame construction having a
having a pitch of up to [4/12] [8/12], the sprinklers shall 3/4" NPT thread. Water seal assembly shall consist of a
be listed for such use. Sprinkler frame and deflector shall Teflon-coated Belleville spring washer and machined
be of bronze frame construction having a'/2" NPT thread. cup with 3 mm glass bulb containing no plastic parts,and
Water seal assembly shall consist of a Teflon-coated having a temperature rating of [155°F (68°C)] [175°F
Belleville spring washer and top-loaded extruded cup (79°C)]. Sprinklers shall have a nominal K-factor of 7.6.
with 3 mm glass bulb containing no plastic parts, and Standard finish: [Bronze] [Chrome-plated] [White
having a temperature rating of [155°F (68°C)] [175°F Polyester] [Special finish— specify]. Recessed
(79°C)]. Sprinklers shall have a nominal K-factor of 5.8. escutcheon assembly shall be a steel, two-piece
Standard finish: [Bronze] [Chrome-plated] [White escutcheon [with '/2" adjustment (Model F2)] [with 3�4��
Polyester] [Special finish—specify]. Residential horizontal adjustment(Model F1)] [of push-on and thread off design
sidewall sprinklers shall be Reliable Model F1 Res 58, with '/2" adjustment(Model FP)]. Standard finish shall be
SIN R3513 (Bulletin 135). [brass][bright chrome] [white painted]. Residential
recessed pendent sprinklers shall be Reliable[Model F1
Model F1 Res 44 & 58 Recessed Res 76 Recessed Pendent/F1] [Model F1 Res 76
Horizontal Sidewall S rinkler Recessed Pendent/F2] [Model F1 Res 76 Fiecessed
p Pendent/FP] SIN R7618 (Bulletin 135).
Use description for the Model F1 Res 58 horizontal
sidewall sprinkler with the following modifications:
Replace "horizontal sidewall sprinkler" with "recessed Model F1 Res 76 CCP Pendent (Concealed)
horizontal sprinkler." Add: Recessed escutcheon Sprinklers shall be [cULus Listed] low flow residential
assembly shall be a steel, two-piece escutcheon with'h" concealed sprinklers engin�ered to provide a minimum
adjustment (Model F2). Standard finish shall be designdensityof0.10gpm/ft overthelistedcoveragearea. I
[brass][bright chrome] [white painted] [Special finish— Listed flows as specified by the manufacturer's technical
specify]. Residential recessed horizontal sidewall data sheets are to be used. Residential sprinklers shall be
sprinklers shall be Reliable Model F1 Res 58/F2, SIN installed in conformance with the manufacturer's installation
R3513 (Bulletin 135). guidelines and the applicable installation standard.
Sprinkler frame and deflector shall be of bronze frame
Model F1 Res 76 Pendent construction having a 3/4" NPT thread. Water seal assembly
Sprinklers shall be [cULus Listed] low flow residential shall consist of a Teflon-coated Belleville spring washer and
pendent sprinklers engine red to provide a minimum machined cup with 3 mm glass bulb containing no plastic
design density of 0.10 gpm/ft�over the listed coverage area. parts, and having a temperature rating of 155 F (68 C).
Listed flows as specified by the manufacturer's technical Cover plate assembly shall consist of a brass cover plate
data sheets are to be used. Residential sprinklers shall be and copper alloy retainer flange. Method of attaching the
installed in conformance with the manufacturer's installation cover plate to the sprinkler cup shall be a push-on and
guidelines and the applicable installation standard. thread-off design allowing a /2" cover plate adjustment.
Sprinkler frame and deflector shall be of bronze frame Cover plate temperature rating shall be 135°F (57°C). A
construction having a 3/4" NPT thread. Water seal assembly plastic protective cap shall be provided and factory installed
shall consist of a Teflon-coated Belleville spring washer and inside the sprinkler cup to protect the sprinkler from
machined cup with 3 mm glass bulb containing no plastic damage,which could occur during construction before the
parts, and having a temperature rating of [155°F (68°C)] �over plate is insta�lled�ltlndard cover plate finishp[White]
[175°F(79°C)]. Sprinklers shall have a nominal K-factor of Custom Color— s eci Concealed endent s rinklers
7.6. Standard finish: [Bronze] [Chrome-plated] [White shall be Reliable Model F1 Res 76 CCP,SIN R7618(Bulletin
Polyester] [Special finish— specify]. Residential pendent 135).
sprinklers shall be Reliable Model F1 Res 76, SIN R7618
(Bulletin 135).
11.
Rel iable . . . For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers • Deluge valves
• Flush automatic sprinklers • Detector check valves
• Recessed automatic sprinklers • Check valves
• Concealed automatic sprinklers • Electrical system
• Adjustable automatic sprinklers • Sprinkler emergency cabinets
• Dry automatic sprinklers • Sprinkler wrenches
• Intermediate level sprinklers • Sprinkler escutcheons and guards
• Open sprinklers • Inspectors test connections
• Spray nozzles • Sight drains
• Alarm valves • Ball drips and drum drips
• Retarding chambers • Control valve seals
• Dry pipe valves • Air maintenance devices
• Accelerators for dry pipe valves • Air compressors
• Mechanical sprinkler alarms • Pressure gauges
• Electrical sprinkler alarm switches • Identification signs
• Water flow detectors • Fire department connection
The equipment presented In this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research
Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances,whenever applicable.
Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable
sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured by
� 4 The Reliable Automatic Sprinkler Co., Inc.
(800)431-1588 Sales Offices Rec cled
� '� � (800)848-6051 Sales Fax �Paper
(914)829-2042 Corporate Offices Revision lines indicate updated or new data.
www.reliablesprinkleccom Internet Address EG.Printed in U.S.A.05/08 P/N 9999970322
Bulletin 014 Rev. F
�
� o Model F1 FR56 Series �
Quick Response �
�
Standard Spray �
-�
Model F1 FR56 Sprinkler Types
Standard Upright � �'i �' ���
Standard Pendent � �3 "
Conventional
Vertical Sidewall �
Horizontal Sidewall t - ��
_ �-.�° `-
Model F1 FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP Upright Pendent
Horizontal Sidewall
� ��
�_� �.
Model F1 FR56 Concealed Sprinkler Types � �j ;
Standard Pendent `- --
,
Listing & Approvals �
1. Underwriters Laboratories Inc. and Certified for ��' -
�:�,
Canada (cULus). �-
2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional
3. Loss Prevention Council (LPCB, UK)
4. VdS Schadenverhutung GmbH
,�"
UL Listing Category _ � -
Sprinklers, Automatic&Open (VNIV) �
Quick Response Sprinkler ��._-, � � y`�:
�, '�'��- 1'
Product Description ` `
Reliable Models F1FR56 Series Sprinklers are quick re- ��
sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed
dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2
sprinkler.
The Models F1 FR56 Series Recessed automatic sprin- � _
klers utilize a 3.0 mm frangible glass bulb. These sprin- �`
klers have demonstrated response times in laboratory tests � �' - � ,
which are five to ten times faster than standard response ��r� ��•��, �
sprinklers. This quick response enables the Model F1 FR56 � '
Series sprinklers to apply water to a fire much faster than � __ � �
standard sprinklers of the same temperature rating. �
The glass bulb consists of an accurately controlled amount Recessed Recessed
of special fluid hermetically sealed inside a precisely manu- Horizontal Sidewall Pendent/FP
factured glass capsule. This glass bulb is specially con-
structed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid Application
in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec-
be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be
expands, forcing the bubble smaller and smaller as the liq- exercised that the orifice size, temperature rating, deflec-
uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat-
to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As-
opening the waterway and allowing the deflector to distrib- sociation or the approving Authority Having Jurisdiction.
ute the discharging water. Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1 FR56 Quick Response Upright, Pendent & Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler ldentification Number
(SIN)
Orifice Size Height Organization
US Metric Upright Pendent
Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position
'/z° (15mm) '/z° NPT(R'/z) 5.6 80 2.25" (57mm) 1, 2,3, 4 RA1425�'� RA1414�'�«>
Conventional-Install in Upright or Pendent Position
15mm�'� '/z° NPT(R'/z) 5.6 80 57mm 3,4 RA1475
�'�cULus listed corrosion resistant(Polyester coated)sprinkler.
«�Polyester coated FM approved sprinkler.
> ,� r '�-
+� '�,
� �4�[�ti �
L�1 ` ��
•• ���'r v V�� �� �� .
I •-v I ��
��� �
7
���_rt . .. .�� � -�- ._ '"",
�.` _ .�.•�d.
���
Upright Pendent Conventional
Model F1 FR56 Quick Response Recessed Pendent Sprinkler
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Sprinkler ldentification Number
Orifice Size US Metric Height (SIN)
Y2" (15mm) Y2" NPT(RY2) � 5.6 80 2.25° (57mm) RA1414
�'� Refer to escutcheon data table for approvals and dimensions.
2 5/8�"DIA. (66.7mm)
2 7/a"Ho�E ora. HOLE IN CEILING
[sz2m�,]
7 75/i6"DiA 2 5�76""0/A. (SBJmm�
[49.2mmj CUP
� � � �
L_=_�==a L=_-�—_�
1=
Model F1 FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal K Factor I Sprinkler
Nominal Sprinkler Approval
Orifice Thread Size Hei ht Or anizations Identification
US Metric g g Numbers(SIN)
Y2" (15mm) 'h" NPT(R1/2) 5.6 8.0 2.25" (57mm) 1,2,3,4
RA1485
15mm 'h" NPT(R1/2) 5.6 8.0 2.25° (57mm) 4�'�
�'�LPC Approval is for pendent position only.
Sprinkler Type Deflector to Ceiling Distance
�� 4-s (Min.- Max.)
Upright 4" (102mm)- 12" (305mm)
Pendent 4" (102mm)- 12° (305mm)
Y ��-�
�;:
Vertical Sidewall
Model F1 FR56 Quick Response Horizontat Sidewall Sprinkler
Deflector: HSW
Installation Wrench: Model D Sprinkler Wrench
Installation Data: Horizontal Sidewall
Nominal K Factor Sprinkler Approval Organizations
Height and Type of Approval Sprinkler
Nominal Orifice Thread Size Identification
US Metric Light Hazard Ordinary Numbers(SIN)
Hazard
'h° (15mm) Y2" NPT(R1/2) 5.6 80 2.63° (67mm) 1,2 1 RA1435
�
FACE OF FlT77NG
TO FACE OF CEILING
DIMENSION 7 )�¢" MIN.
[37.Bmm]
2 1/4" HOLE DIA. q"_72"
- [57.2mmJ ��8 [701.6mm-304.8mm]
�3.2mm) CEILING TO
�, ' ' 1"X 1/2" REOUCER DEFLECTOR
,.» ��,:._ � �
n^
J I
��� —I
i I"�� � `"�'���EtI� � i _�_-
.,.,"���� � \ I�Ilill�� � \--r1 —
I I IIIIII �
.�,.`�. . �I�� � �5/�6 Q�f�. �IIIII � ____
91A
�V �_—_
[49.2mm] iiiii i 2 27/32" DIA.
nni
I 110 i (722mm]
nni
L—,. � i—iJ
- -"L__
Horizontal Sidewall TURN COLLAR UNTIL �� °�
TIGHT AGAINST SPRINKLER `\`�
WRENCH BOSS. �
� '
ADJUSTMEN7
073FG03A
(>) REFER TO ESCUTCHEON DATA TABLE FOR APPRO�ALS AND DIMENSIONS.
(2) FM APPROVED FOR 4"" — 6""(1O1.6MM — 152.4MMJ CEILING TO DEFLECTOR.
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
3.
Model F1 FR56 Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
Nominal ��K" Factor Thread Temp. Rating Max. gulb Sprinkler
Orifice Size Model Ambient Color Approvals Identification
US Metric Sprinkler Cover Temp Number(SIN)
'/z" (15mm) 5.6 80 'h" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1, 2 RA1414
'/z° (15mm) 5.6 80 'h" NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 2,4�'� RA1414
'/z" (15mm) 5.6 80 'h" NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1, 2 RA1414
Yz" (15mm) 5.6 80 Y2" NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°C Green 1, 2 RA1414
�'�For VdS only=155°F/68°C Norbulb and 1/2° [12,7mm]adjustment.
7'x 7/?"REDUC/NG
rEE oR E�eow
� i"x �/2°REOUaNc
J� _._. rEE oR E�eaw \
—lL_ — � --�I--l�— — �— — ---�` --i---- ,,--- —
� r 2 5/8 DlA �-------� i -------�
2 5�16"" DlA � ` HOLE /N CEILING �� " 2 5/8" DIA.
�- - — 2 5/76" D/A � ', ►{
HOLE lN CEILING
CUP � — �'� =__
1 1�2° MAX CUP
— �i�� � tl� FACE OF Fl7TlNG � �O.e Vk3�� 1 1�2'" MAX.
' TO FACE OF CEILING �-��--� ' FACE OF FI77ING
�_� �I I ��� DIMENSION � TO FACE OF CEILING
� ���T'�-- '� DIME�SION
CEIUNG � ���"
� _ CEIL/NG --=—�i
7 2" MAK �� �
� 5 76'� MAX_ 3 4'"
i
/ , 15�76�� � �
7
CO�ER ADJLSTMEN CO�ER ADJUSTMEN7 l�
/
� I
COI/ER PLATE � CO�ER EMBLY �
lISSEMBLY �3 5�76" DlA � � 5�16" DIA.
SPRINKLER � SPk/NKLER�
1/2" ADJUSTMENT m�FCm 5 16" ADJUSiMENT o„F�oa
Figure 1 Figure 2
Installation Aid
A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac-
Important: The F1 FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet-
plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135°F
Installation (57°C) or 165°F (74°C) rated Model CCP push on cover
Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as-
as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible
standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover
The Model F1 FR56 Recessed Quick Response Sprin- plate assemblies provide either'/2" (13mm)or 5/,6" (8mm)
klers are to be installed as shown.The Model F1 or F2 Es- of cover adjustment.
cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have
to be used with the Model F1 FR56 Sprinklers. The use positive pressure in the space above.
of any other recessed escutcheon will void all approvals After a 25/a" (67mm) diameter hole is cut in the ceil-
and negate all warranties. ing, the sprinkler is easily installed with the Model RC1
When installing Model F1 FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be
el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1
installing F1 FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching
other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When
NOTE: A leak tight '/2" NPT (R1/2) sprinkler joint can inserting or removing the wrench from the sprinkler/cup
be obtained with a torque of 8-18 ft-Ibs (10,8-24,4 N-m). assembly, care should be taken to prevent damage to
Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHER PART
torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed
klers. onto the cup. Final adjustment is made by hand turning
The Model F1 FR56/CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact
'/z" orifice, '/z" NPT (R1/2), 135°F (57°C), 155°F (68°C), With the ceiling. Cover plate removal requires turning in
175°F (79°C) or 200°F (93°C) Model F1 FR56 Pendent the counter clockwise direction.
`DuPont Registered Trade Mark
4.
After installation, inspect all sprinklers to ensure that Sprinkler Types
there is a gap between the cover plate and ceiling and Standard Upright
that the four cup slots are open and free from any air flow Standard Pendent
impediment to the space above. Conventional
Concealed cover plate/cup assemblies are listed only Recessed Pendent
for use with specific sprinklers. The use of any other con- Vertical Sidewall
cealed cover plate/cup assembly with the Model F1 FR56 Horizontal Sidewall
Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall
cover plate assembly on any sprinkler with which it is not Concealed pendent
specifically listed my prevent good fire protection and will
void all guarantees, warranties, listings and approvals. Maximum Working Pressure
Glass bulb sprinklers have orange bulb protectors to 1�5 psi (12 bar)
minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar)
installation. REMOVE THIS PROTECTION AT THE TIME Finishes �'�
THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR
FIRE PROTECTION. Removal of the protectors before this Standard Finishes
Sprinkler_ Escutcheon_ Cover plate
time may leave the bulb vulnerable to damage. RASCO gronze Brass
wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome
are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White
CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated�°��5� White Painted
THE PFiOTECTORS. Special Application Finishes
Sprinkler Escutcheon_ Cover plate
Temperature Ratings Bright Brass�3� Bright Brass Bright Brass
Sprinkler Black Plated2 Black Plated Satin
Max.Ambient Black Paint Black Paint Off White
Classification Tem erature Temp. Bulb Color Off White�2� Off White Black Paint
�'C �'F Satin Chrome Satin Chrome Black Plated
Ordinary 57 135 100°F(38°C) Orange c�� Other finishes and colors are availab�e on special order.
Ordinary 68 155 100°F(38°C) Red Consult the factory for details.
Intermediate 79 175 150°F(66°C) Yellow «� cULus Listed only.
Intermediate 93 200 150°F(66°C) Green �3� 200°F(93°C)maximum.
High�'� _ 141 286 225°F(107°C) Blue �'� cULus listed°corrosion resistance"applies to SIN Numbers
�'�Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white.
�y� FM Approvals finish as"Polyester coated°applies to SIN Number
Escutcheon Data �'� RA1414(Pendent)in standard black or white.
Face of Fit6ng to
Escutcheon �rovals Adjustrnerrt A CeilingorWall Ordering Information
Model Dimension
Dimension Specify:
F1 1,3,4 M�Recess 1�iz��3a.1mm) 3/,�'-15/,�' 1. Sprinkler Model
MinRecess 3/4'(19.1mm) �5mm-24mm) 2. Sprinkler Type
F2 1,2,3,4 MwCReCess 1 Yz"(38.1mm)� 3/,e°-"/,e°� 3. QrIfICO SIZe
Min Recess 1" 25mm 5mm-17mm
FPPush-on/ MaxRecessed 'hs"(11mm) 1'/2' (38.1mm) 4. Deflector Type
Thread-off 1'4 MinRecessed 'S/,e 24mm 1° 25.4mm 5. Temperature Rating
�'�SIN:RA1435-cULus and FM permits use with F1 or F2 escutcheons for light 6. Sprinkler Finish
nazara oniy. 7. Escutcheon Type
8. Escutcheon Finish (where applicable)
Maintenance 9. Cover plate Model
The Models F1 FR56 and F1 FR56 Recessed Sprinklers 10. Cover plate Thread size
should be inspected quarterly and the sprinkler system 11. Cover plate Temperature
maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment
sprinklers with soap and water, ammonia or any other 13. Cover plate Finish
cleaning fluids. Remove dust by using a soft brush or
gentle vacuuming. Remove any sprinkler which has Note:When Model F1 FR56 Recessed sprinklers are ordered,the sprin-
been painted (other than factory applied) or damaged klers and escutcheons are packaged separately.
in any way. A stock of spare sprinklers should be main-
tained to allow quick replacement of damaged or oper-
ated sprinklers. Prior to installation, sprinklers should be
maintained in the original cartons and packaging to mini-
mize the potential for damage to sprinklers that would
cause improper operation or non-operation.
5.
Rel iable. . . For Com lete Protect I O r1
p
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers • Deluge valves
• Flush automatic sprinklers • Detector check valves
• Recessed automatic sprinklers • Check valves
• Concealed automatic sprinklers • Electrical system
• Adjustable automatic sprinklers • Sprinkler emergency cabinets
• Dry automatic sprinklers • Sprinkler wrenches
• Intermediate level sprinklers • Sprinkler escutcheons and guards
• Open sprinklers • Inspectors test connections
• Spray nozzles • Sight drains
• Alarm valves • Ball drips and drum drips
• Retarding chambers • Control valve seals
• Dry pipe valves • Air maintenance devices
• Accelerators for dry pipe valves • Air compressors
• Mechanical sprinkler alarms • Pressure gaugesldentification signs
• Electrical sprinkler alarm switches • Fire department connection
• Water flow detectors
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc. � Recycled
� � (800)431-1588 Sales Offices Paper
� '� � (800)848-6051 Sales Fax Revision lines indicate updated or new data.
(914)829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG.Pr�nted�n u.s.A o2/i i P/N 99999�0300
ES-A-C400/C400N/C400Z
TM • �
Colt Series C400, C400N, C400Z A M E S
FIRE&WATERWORKS�
Reduced Pressure Zone Assemblies
Sizes: 21/z" — 10" (65 —250mm)
� � �
� � �
�. •,
C400 OSY
_ --� r ' ie v
- �� � � �
J C400N BFG "� � �_ '* �
�,
,
�. ,
f 1;, � ' ��� 1
�_. .
— - ��
Features The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies
• Extremely Compact Design provide protection to the potable water system from contamination
in accordance with national plumbing codes. The Colt C400, C400N,
• 70% Lighter than Traditional C400Z are normally used in health hazard applications for protection
Designs against backsiphonage, backpressure and the fouling of either check valve.
• 304(Schedule 40) Stainless Steel
Housing &Sleeve
• Groove Fittings Allow Integral Specifications
Pipeline Adjustment The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies shall
• Patented Link Check Provides consist of two independent Link Check modules, a differential pressure
Lowest Pressure Loss relief valve located between and below the two modules, two drip
• Unmatched Ease of Serviceabiiity tight shutoff valves, and required test cocks. Link Check modules and
• Available with Grooved Butterfly relief valve shall be contained within a sleeve accessible single housing
Valve Shutoffs constructed from 304 (Schedule 40) stainless steel pipe with groove end
connections. Link Checks shall have reversible elastomer discs and in
• May be Used for Horizontal or N operation produce drip tight closure against the reverse flow of liquid
Pattern Installations caused by backpressure or backsiphonage. Assembly shall be Colt
• Replaceable Check Disc Rubber C400, C400N, C400Z as manufactured by the Ames Company.
'The wetted surface of this product
contacted by consumable water contains IMPORTANT,'INQUIRE WITH GOVERNING AUTHORITIES
less than 0.25%of lead by weight. FOR LOCAL INSTALLATION REQUIREMENTS
Job Name Contractor
Job Location Approval
Engineer Contractor's P.O.No.
Approval Representative
Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contactAmes Technical
Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make
such changes and modifications on Ames products previously or subsequently sold.
www.amesfirewater.com
Configurations Pressure — Temperature
• Horizontal Temperature Range: 33°F— 140°F (0.5°C—60°C)
"Z" pattern horizontal Maximum Working Pressure: 175psi (12.1 bar)
• "N" pattern horizontal Note:When installing a drain line on Series C400 backflow
preventer use 400/500 air gap.See ES-A-AG/EL/TC for additional
information.
Materials
• Housing &Sleeve: 304 (Schedule 40) Stainless Steel Available Models
• Elastomers: EPDM, Silicone and Buna `N' Suffix:
• Link Checks: Noryl°, Stainless Steel NRS - non-rising stem resilient seated gate valves
• Check Discs: Reversible Silicone or EPDM OSY- UVFM outside stem and yoke resilient seated
• Test Cocks: Bronze Body Nickel Plated gate valves
• Pins&Fasteners: 300 Series Stainless Steel BFG - UVFM grooved gear operated butterfly valves
with tamper switch
• Springs: Stainless Steel
"'OSY FxG - Flanged inlet gate connection and grooved
outlet gate connection
Noryl°is a registered trademark of SABIC Innovative PlasticsT"^. "OSY GxF - Grooved inlet gate connection and flanged
outlet gate connection
Approvals �OSY GxG - Grooved inlet gate connection and grooved
outlet gate connection
�pss►F��, Available with grooved NRS gate valves -consult factory�
FM Post indicator plate and operating nut available-consult factory
� o .
H55E C UL US ��� Approved 'Consult factory for dimensions
C US
1013 B64.5
For additional approval information please contact the factory or visit our website at www.amesfirewater.com
Dimensions — Weights
� �IT
iI C(open) , � ���
J
� � I i M oOo,
� �o � - ' ,� ,�°- o o�
, �
� ' —
' O O ' �
�
� � I ( . �,�� � o 0
p � � ,
, ,
� ,
�
� --------------------- H '
------------------
-------------------- p --------------- ------ P ----
---- -------------------------- G -----------------------
C400
� � �
A C(OSY) C(NRS) D G H I J M P C400 C400N
NRS OSV NRS OSV
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm Ibs. kgs. Ibs. kgs. Ibs. kgs. Ibs. kgs.
2Yz 65 31 787 163/a 416 93/a 238 6'h 165 29�/s738 21�h 546 15Yz 393 813/s 223 219/s 548 93/s 234 118 54 128 58 126 57 136 62
3 80 31"/s 805 18'/s 479 10Ya 260 6"/s 170 30Ya 768 22Ya 565 17Ys 435 93/s 233 23'/a 587 10Yz 267 134 61 148 67 147 67 161 73
4 100 33Yz 851 223/a 578 123/s 310 7 178 33 838 23Yz 597 18'/z 470 915/s 252 26'h 673 113/s 284 164 74 164 74 187 85 187 85
6 150 44 1118 30'/a 765 16 406 8'/z 216 443/a1137 333/a 857 233/s 589 13'/s 332 323/a 832 15 381 276 125 298 135 317 144 339 154
8 200 50 1270 373/a 959 1915/s 506 9"/e 246 54'/s1375 405/a 1032 27'/s 697 15��/s 399 37Ye 943 173/s 437 441 200 483 219 516 234 558 253
10 250 57'/z 1461 453/a 1162 23'3/s 605 113/s 285 66 1676 50 1270 32Yz 826 175/s 440 463/s 1178 20 508 723 328 783 355 893 405 950 431
Dimensions — Weights
z'�'
—.��__ j � �
, i
- o o,
$ � � °o
, ,
- --------------------- H -----------------I J i
------------------------- � -------------------------
I ------- p ------
C400N BFG/C400Z BFG
� � �
G H I J M P C400N,C400Z
in. mm in. mm in. mm in. mm in. mm in. mm in. mm Ibs. kgs.
2Yz 65 32'/z 826 21 Yz 546 15'/z 394 9Yz 241 2113/s 555 1113/s 300 67 30
3 80 34 864 22�/a 565 165/s 414 10�/,s 256 23Ys 587 12�/a 308 70 32
4 100 355/a 905 23'h 597 173/,s 437 1015/is 279 2415/,s 634 125/a 321 87 39
6 150 46'/z 1181 333/a 857 20'/z 521 13'/z 343 28'/a 718 15 382 160 73
� � � � i o �
C
0
� O
D
--------------------- ---------'---
---------------------------------------- p —----_ ��-------------------- ---------- P -----------
C400 BFG
� � �
A C D P
in. mm in. mm in. mm in. mm in. mm Ibs. kgs.
4 100 283/a 730 73/a 197 63/a 162 9'/z 241 66 30
6 150 37 940 9"/,s 246 7'/,s 189 14'/a 362 122 55
Capacity - C400 BFG
� = Rated Flow �� = UL Tested
4" (100 mm) 6" (150 mm)
kPa psi * *,r kPa
172 25 psi ,r **
110 16
138 20 96 14
83 12
103 15 69 10
69 10 55 8
41 6
34 5 2$ 4
14 2 —
0 0 0 0
0 100 200 300 400 500 600 700 800gpm 0 200 400 600 800 1000 1200 1400 1600gpm
0 380 760 1140 1520 1900 2280 2680 30401pm 0 760 1520 2280 3040 3800 4560 5300 60601pm
15 fps 15 fps
4.6 mps 4.6 mps
Capacity
UUFM Certified Flow Characteristics
N&Z Flow characteristics collected using butterfly shutoff valves.
See literatue S-Colt-400,500 for gate valve flow characteristics
� = Rated Flow �� = UL Tested
Horizontal N - Pattern----- Z- Pattern
2%" (65mm) 6" (150mm)
kPa psi *
124 18 ** kPa psi *
124 18 **
110 16 N 110 16 N
96 14 96 14 H
83 12 H 83 12
69 10 69 10 �
55 8 55 8
41 6 41 6
0 50 100 150 200 250 300 350 gpm 0 300 600 900 1200 1500 gpm
0 190 380 570 760 950 1140 1330 Ipm 0 1140 2280 3420 4560 5700 Ipm
15 fps 15 fps
4.6 mps 4.6 mps
kPa psi 3" (SOmm) S" (200mm)
110 16 * ** kPa psi * **
124 18 Z
96 14 N 110 16 � H
83 12 Z 96 14
H
69 10 83 12
69 10 �
55 8 55 8 �
41 6 41 6
0 100 200 300 400 500 gpm 0 500 1000 1500 2000 2500 gpm
0 380 760 1140 1520 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm
15 fps 15 fps
4.6 mps 4.6 mps
4" (100mm) 10" (250mm)
kPa psi * **
179 26 Z kPa psi * **
. N 110 16 Z
152 22 H 96 14 N
124 18 83 12 H
96 14 69 10
69 10 ` 55 8
41 6
41 6 28 4
0 100 200 300 400 500 600 700 800 gpm 0 500 1000 1500 2000 2500 3000 3500 gpm
0 380 760 1140 1520 1900 2280 2660 3040 Ipm 0 1900 3800 5700 7600 9500 11400 13300 Ipm
15 fps fps
4.6 mps mps
� ���
A M E S ��V%' � 9001-2008
FIRE&WATERWORKSg www.amesfi rewater.com C E R T 1 F I E D
A Watts Water Technologies Company USA: Backflow- TeL(916)928-0123•Fax(916)928-9333
Control Valves- Tel.(713)943-0688•Fax(713)944-9445
Canada: Tel.(905)332-4090•Fax(905)332-7068
ES-A-C400/C400N/C400Z 1151 O 2012 Ames Fire&Waterworks
BERMAD FirE ProtECtion � �
700 SEriEs
700E DEIugE VaIvE Data
Description
BERMAD 700E Deluge Valves are globe valves with - -
integral unitized double chamber actuator that consists of __ _ .
one single moving assembly, which includes a diaphragm '
assembly, a flat seal disk and a stainless steel removable � ;
seat. These automatic water control valves are designed , � -'
for high pressure service, in vertical or horizontal
installations and are available in diameter sizes from 1Yz" I +
to 16"; DN40 to DN400. � " • �•'
The BERMAD 700E valves are used for water flow control �� � ,��
in Deluge, Pressure Control Deluge, Preaction or Water/
Foam systems, and are manufactured from materials � �F_ '
suitable for freshwater or alternative for seawater, foam � - � ` �
concentrate or other corrosive fluids.
The 700E Deluge Valve is held closed by system water
pressure trapped in the control chamber. When the
releasing system operates, pressure is released from the -
control chamber, and the seal disc opens to allow water
to flow into the system.
The 700E valve body design includes a single, full bore
seat with unobstructed flow path, free of any in-line ribs,
supporting cage, or stem guides. Main FEaturEs
The 700E "Y Type" design provides high flow capabilities ■ High Pressure Construction—
with minimum head loss. 400 psi (28 bar) rating available
The integral unitized double-chambered actuator provides • Integral unitized double chamber actuator
a combination of positive, immediate response with with single moving assembly
smooth hammer-free, drip-tight closing. ■ In-line serviceable, field replaceable internals
The whole actuator can be easily removed for a quick ■ Obstacle free, full bore
in-line inspection and servicing. ■ Available in corrosion resistant materials
Valve actuation is accomplished by one moving assembly ■ Designed to be reset without opening the valve
which includes a replaceable flat diaphragm, harnessed ■ Compatible with electric/hydraulic/pneumatic
to the diaphragm assembly, a stainless steel stem and a release and pressure control trim systems
flat seal disk assembly.
The balanced seal-disk assembly with its resilient seal Approvals
enables controlled actuation, high durability and perfect ■ UL Listed to UL 260 from 5 to 300 psi; 0.3 to 21 bar
drip-tight sealing, even under harsh conditions. WP, 2" through 10"; DN50 through DN250
■ ABS Approved for 300 psi; 21 bar WP, 1�/z" through
AccESSOries 12"; DN40 through DN300
■ Lloyd's Register Type Approval for 300 psi; 21 bar WP,
The BERMAD 700E Deluge Valve shall be trimmed with 1�/z" through 16"; DN40 through DN400
the original components and accessories per specification ■ Fire Test Certified to ISO 6182 part 5, 11h" through
and in accordance with valve functions and applications. 16"; DN40 through DN400
Where additional specifications and/or signaling devices
are required for a specific application, refer to system data Notes:
for the system used, and to the BERMAD data sheet and 1.The 700E valve shall be trimmed with specific components I
&accessories.
Installation, Operation & Maintenance for specific model 2.The 700E valve must be installed and maintained in
Y2qUir2d. compliance with the most recent BERMAD publications.
.�
��
..�arna�.� _
BERMAD FirE ProtECtion � �
• � - - � - • 700 SEriEs
Construction Materials
The BERMAD 700E valves are available in a variety of materials to ensure optimal suitability for a wide range of
applications. For operation involving exposure to internal and/or external corrosive conditions, valves are constructed
from corrosion-resistant materials making them suitable for use with seawater, brackish water, or corrosive environments
such as seashore, petrochemical and other industrial facilities.
S�andard Configuration�
1 �
' � 11
2 �� .
1 Cover Ductile Iron - 12
-_ __ _ _ ___
2 Cover Bolt Z.C. Plated Steel 3 13
3 Cover Nut Z.C. Plated Steel 4 „ `; 14
-
4 Separation Partition Ductile Iron 5 '�� ' 15
_. _ _ __ . -
5 Stud Z.C. Plated Steel ��� "
6 • �=
� - - . �
6 Stud Nut Z C. Plated Steel 7 , ,' � •�` 16
7 Valve Bod Ductile Iron �� �.,�'�'� � 17
y
8 _ Spring _ S S.302 g . �' - �
9 Removable Seat S.S.304 , .� � �
10 Seal NBR(Buna-N) �� 18
11 Upper Plug (6 20'')_ Brass
- 9 19
12 Shaft Lock Nut S.S. 303
_ _. .. .. . ..... ___ .....................
13 Shaft Nut S.S. 303 �
14 Diaphragm Washers S.S.431 10 9
,
15 Diaphragm NBR(Buna-N) � °`
16 Bearing Screw S.S. 303 � r
__ _
_
17 Bearin Bronze � I
18 Shaft g S S. 303 - -�� �
19 Seal Disk S.S.431 " �'
Specifications
Castings
■ Ductile Iron to ASTM A536 65-45-12(coated)
�Cast Steel ASTM A216 Grade WCB(coated) Pressure Rating
■ Nickel Aluminum Bronze ASTM B148 C95800
�Stainless Steel 316 ASTM A351 Grade CF8M �?. �, - • •
s,,,
�Super Duplex ASTM A890 Grade 5A � ' '
■ Hastelloy G276 � ;� �, ��,f �' � � �
Bolting:
■Standard External Bolting:Zinc Plated Steel Flanged ANSI B16.42 #150RF 250 17.4
_-- _.
■Optional: S.S.316 to ASTM A320 Gr.B8F Flan ed ANSI B16.42 #300RF 400 28
9
Internal Wetted Parts: Ductile Flanged ISO 7005-2 PN 16 235 16
�Stainless Steel 303 ASTM A582 95B S30300A Iron Flanged ISO 7005-2 PN 25 365 25
■Stainless Steel 304 ASTM A743 Grade CF8 Grooved ANSI C606 300 400 25
�Stainless Steel 431 ASTM A743 Grade CA15M
■ Bronze ASTM B505 Grade C83600 Threaded BSP/NPT 300/PN25 400 25
--- - - ------ --- - -- -- --
■ Internal Spring-S.S.302 Cast Flanged ANSI 616.5 #150RF 250 17.4
_ .. _ .___ _. ..____._ __..._.
Optional Internal Wetted Parts: Steel Flanged ANSI B16.5 #300RF 400 28
■Stainless Steel 316 ASTM A351 Grade CF8M & Flanged ISO 7005-2 PN16 235 16
■ Nickel Aluminum Bronze ASTM B148 C95800 Stainless Flanged ISO 7005-2 PN25 365 25
■ Monel 400 Steel
■ Hastelloy C-276 Threaded BSP/NPT 300/PN25 400 25
■Internal Spring- Inconel Flanged ANSI B16.24 #150RF___ _250 17.4
Elastomers (Diaphragm Fs Seals) Ni-AI Flanged ANSI B16.24 #300RF 400 28
_._. __.._.__ . ___ __ _-
■ NBR, Polyamide fabric reinforced Nitrile(Buna-N), Bronze Flanged ISO 7005-2 PN 16 235 16
_ _ _ _.. .....
Temperature Rating 80°C Flanged ISO 7005-2 PN25 365 25
� EPDM, Polyamide fabric reinforced Ethylene-Propylene, Note:
Temperature Rating 90°C
2 1. Factory pressure testing:Each valve is tested at 1.6 of pressure rating.
Coating 2. Water Temperature:0.5-50°C(33-122°F)
� Electrostatic Powder Coating Polyester 3. Standard flange facing:Raised Face(RF),Serrated Finish.
■ High Built Epoxy Fusion-Bonded with UV Protection,Anti-Corrosion Flat Face(FF)flanges available on request.
■Color: Fire Red to RAL 3002
Note:Internal&External coating applied on Ductile Iron or Cast Steel Castings only.
_�
�
_ ��':
BERMAD FirE ProtECtion � �
' • • • � � - � - - 700 SEriEs
Flow Chart
psi bar
15.0 1.0
12.5 ', . ' '
10.0 _ '
iV2 ' I 2Vz' , : '3' 4. 6. ,,_ 8. 10' . ,' 12' 1q i6•
�� rha�m .� �tti,�g oe � ��� �
,M, ��
,;.,
7.5 0.5 _ ' *
N 2" _ , , ,
� �
O _ , i,
J
m 5.0 I ' ' ', ' ' ',
�
cn ,_ _,
�
� ', '
a ' ' '
2.5 I ', ', ', ', ', '
1.5 �.1 , , '
10 50 100 500 1,000 5,000 m3/h
50 75 100 250 500 750 1,000 2,500 5,000 7,500 1Q000 15,000 20,000 gpm
Flow Properties F�ow Rate
Inch 1'/z��_2„ 2,�2�� 3�� 4�� 6" 8�� 10�� �2�� �4�� y 6��
Kv-Y 50 55 115 200 460 I 815 1,250 I 1,850 1,990 3,310
� Cv-Y 58 64 133 230 530 I 940 I 1,440 I 2,140 2,300 3,820
� K-Y 3.9 I 9.2 4.9 3.9 3.7 I 3.8 3.9 I 3.7 5.9 3.7
?' Leq-m,Y 10.3 33.4 21.6 23 37.5 I 53.9 I 70 I 85.6 159.9 112.7
V Leq-feet,Y 33.8 109.5 70.8 75.6 123 I 176.9 229.5 I 280.8 524.5 369.6
Kv-A 55 61 127 220 506 897 1,375 2,035 2,189 3,641
� Cv-A 64 70 I 146 I 250 I 580 I 1,040 I 1,590 I 2,350 2,530 4,210
� K-A I 3.2 I 7.6 4.0 3.2 3.1 II 3.1 I 3.2 I 3.1 4.9 3.0
a Leq-m,A 8.5 27.6 17.8 19.0 37.0 44.6 I 57.8 70.7 132.1 93.1
Leq-feet,A 28 90.5 58.5 62.5 101.6 146.2 I 189.7 232 433.4 305.5
Valve flow coefficient, Kv or Cv Kv(Cv)=Q Gr Equivalent Pipe Length, Leq Leq=Lk•D
Where: �P Where:
Kv = Valve flow coefficient(flow in m3/h at 1 bar Diff. Press.) Leq= Equivalent nominal pipe length(m ;feet)
Cv = Valve flow coefficient(flow in gpm at 1 psi Diff. Press.) Lk = Equivalent length coefficient for turbulent
Q = Flow rate(m3/h ;gpm) flow in clean commercial steel pipe(SCH 40)
4P = Differential pressure(bar; psi) D = Nominal pipe diameter(m;feet)
Gf = Liquid specific gravity(Water=1.0)
Note:
The Leq values given are for general consideration only.
CV = 1.155 KV Actual Leq may vary somewhat with each of the valve sizes.
Flow resistance or Head loss coefficient, K=4H 2J
Where: VZ 3
K = Flow resistance or Head loss coefficient(dimensionless)
4H = Head loss (m ;feet)
V = Nominal size flow velocity(m/sec ;feet/sec.)
g = Acceleration of gravity(9.81 m/secz; 32.18 feet/secz)
_�
��
..�arna�.� _
BERMAD FirE ProtECtion � �
' • • � • � 700 SEriEs
�� Metric
Flanged
'°^'� �aL,� �,_ A 'B I''; ,ec� <r, � sR �, 1R,�,,�� , I '� ,. 10,._ .1 � R 11 0 .�' .,sA41 �„a.
' " L'" ° - ,�-- .
L (mm) 10 205 222 250 320 415 500 605 725 733 990
co LG�4> (mm) N/A N/A N/A 250 320 415 500 N/A N/A N/A N/A
T ........ .............. ............. . ......... ......... ......................... .."""'..._....._......._...._..._'.. .."..."._..._.._......._.._.."""'_. ..._....... ....._.... .. .._..._...._"
z W (mm) 165 165 178 200 223 320 390 480 550 550 740
- ----- - - - - -- -- - --------- - -- ----- - --
� R (mm) 78 83 95 100 115 143 172 204 242 268 300
� La (mm) 124 124 149 152 190 225 265 320 396 400 450
° ha (inch) 85 85 109 102 127 152 203 219 273 279 369
*� Hy (inch) 239 244 257 305 366 492 584 724 840 866 1,108
-
z Ha (inch) 227 227 241 281 342 441 545 633 777 781 1,082
Q Weight Y (kg) 10.6 10.6 13 22 37 75 125 217 370 381 846
_ . ___ _ _ _ . __ .__ __ __ _ __ _ __ __ _ _ _ _ ___ ____ .
Weight A (kg) 10 10 12 21.5 35 71 118 205 350 370 800
L (mm) 210 210 222 264 335 433 524 637 762 767 1,024
N -W----------------- ------------------------------------ ----------- -----
(mm) 165 165 185 207 250 320 390 480 550 570 740
� R (mm) 78 83 95 105 127 159 191 223 261 295 325
� La (mm) 124 124 149 159 200 234 277 336 415 419 467
o ha (inch) 85 85 109 109 127 165 216 236 294 299 386
_.. . . ........ __ ... . __ . ...
� Hy (inch) 239 244 257 314 378 508 602 742 859 893 1,133
____ _. .. _._ .__ .__.___. _ __. _____ _ _. ..___.._. .._ __. ___--.--. _ _. __
� Ha (inch) 227 227 251 287 650 454 558 649 796 801 1,099
Q Weight Y (kg) 12.2 12.2 15 25 43 85 146 245 410 434 900
Weight A (kg) 11.5 11.5 13.5 23 41 81 138 233 390 421 855
a(') (m m) �h �/2 �/Z 1/2 1/z 1/z 1h �/z �/z �/2 1/2
---------------------------------------------------------------- -------------------------- ------------ -------------------------- ------------------------- ------------ -------------------------- - -----------------
b��� (mm) �/z �/z �/z �/z �/z �/z �/z �/z �/z �/z �/z
C�'� (mm) 3/a 3/a 3/a 3/a 3/a 2 2 2 2 2 2
_. . . . _ __ _ __ __. ._.__ _.._ . __
d�2�(optional) (mm) 3/a 3/a 11h 11h 2 2 2 2 2 2 2
-- -- -- --... -- - --- - -- - -- -- -- --- - ------- -- -- ------ -- --- - -- -- ----- ---
Control Vol. �3>(Liter) 0.125 0.125 0.125 0.3 0.45 2.15 4.5 8.5 12.4 12.4 29.9
(1) (a), (b), (c)are NPT thread ports
(2) (d)is BSPT threaded Optional drain port
(3)(Control Volume)is Control Chamber Displacement Volume of liquid pushed when valve opens
(4)LG for Grooved ends(see available sizes)
b �� b c
Y Body TypE AngIE Body TypE t
a I a
Hy Ha ,
_ ... I _ `�' I _
- � --- -- � � � ha
R '
�
r _
_ _ a _ -
d a.—,
L& LG� �La�
- —c
c
O O
� O � O
W - I -- I -
4 II � �
O � O
�b O O
—b
�
��
_ ��
BERMAD FirE ProtECtion � �
' ' • • � • � 700 SEriEs
�� English
v�
Flanged
Size(inch) 1�/z" 2" 2�/2" 3" 4" 6" 8" 10" 12" 14" 16"
L (inch) 8.1 8.1 8.3 9.8 12.6 16.3 19.7 23.8 28.5 28.9 39.0
co LG�4� (inch) N/A N/A N/A 9.8 12.6 16.3 19.7 B/A B/A B/A B/A
T .......... ......... ............... ........... ................... ..... .. .... .._.._..._....._..._..._.._.._.__....... ........_ ._......_.... ._......_... . ........_. ........ ........_...._..
z W (inch) 6.1 6.1 7.0 7.9 8.8 12.6 15.4 18.9 21.7 21.7 29.1
� --- -- --- -- -- -- -- - ------ - - - --- - --- --- ---- - --- -- -- ---- ----
o R -(inch) 3.1 3.3 3.7 3.9 4.5 5.6 6.8 8.0 9.5 10.6 11'8
� La (inch) 4.9 4.9 5.9 6.0 7.5 8.9 10.4 12.6 15.6 15.7 17.7
° ha (inch) 3.3 3.3 4.3 4 5 6 8 8.6 10.7 11 14.5
*� Hy (inch) 9.4 9.6 10.1 12 14.4 19.4 23 28.5 33.1 34.1 43.6
-
z Ha (inch) 8.9 8.9 9.9 11.1 13.5 17.4 21.5 24.9 30.6 30.7 42.6
Q Weight Y (Ib) 23 23 29 49 82 165 276 478 816 840 1,865
___ __ _ _. _ __ __ _._ _ _ _ _ _ _ __ _ _ _ _ _. __
Weight A (Ib) 22 22 27 47 77 157 260 452 772 216 1,764
L (inch) 8.3 8.3 8.7 10.4 13.2 17 20.6 25.1 30 30.2 40.3
N W (inch) 6.5 6.5 7.3 8.1 9.8 12.6 15.4 18.9 21.7 22.4 29.1
a R -(inch) 3.1 3.3 3.7 4.1 5 6.3 7.5 8.8 10.3 11.6 12.8
� La _ (inch) 4.9 4.9 5.9 6.3 7.9 9.2 10.9 13.2 16.3 16.5 18.4
o ha (inch) 3.3 3.3 4.3 4.3 5.3 6.5 8 5 9.3 11.6 11.8 15.2
_ _...._. __ . __ .._ _..._...... . . _ _ _ _. .. .. _.. _ ............
� Hy (inch) 9.4 9.6 10.1 12.4 14.9 20 23.7 29.2 33.8 35.2 44.6
___ __ .____ _.___._.. _ __. . .._ . ___ __ _._.. ._.. __ __ _._.. ._._ ._..____._ _ _.._..
� Ha (inch) 8.9 8.9 9.9 11.3 13.8 17.9 22 25.6 31.3 31.5 43.3
Q Weight Y (Ib) 27 27 33 55 95 187 322 540 904 957 1,984
Weight A (Ib) 25 25 30 51 90 179 304 514 860 928 1,88
a�'> (inch) 1/z �/z �/z �/z �/2 �/z 1h 1/z Yz �/z �/2
N b��> (inch) �/z �/z �/z �/z �/z �/z �/z �/z �/z �/z �/z
O C��� (i n c h) 3�4 3�4 3�4 3�4 3�4 2 2 2 2 2 2
......... ....__- -�-�----.�___.___..._.. ._._ .. _._._.__ ...._.
_ . _.._............._ _._ _ . . ._._. . . _. _.._... ..._.._..__._..
d�2>(optional) (inch) 3/a 3/a 1'h 1'h 2 2 2 2 2 2 2
-- - -- -- -- - --- ---- -- -- --- --- ---- - - -- - --- --- ---- - - -- -- -
Control Vol. �3�(Gal.) 0.04 0.04 0.04 0.08 0.12 0.57 1.19 2.25 3.28 3.28 7.88
(1) (a), (b), (c)are NPT thread ports
(2) (d)is BSPT threaded Optional drain port
(3)(Control Volume)is Control Chamber Displacement Volume of liquid pushed when valve opens
(4)LG for Grooved ends(see available sizes)
Y Body Type b � Angle Body Type
b� , c
a a
Hy Ha I
- I --- -- --I-- -,I, ha
R
�_ -�
_ a _ - -
�� d a
L& LG� �La�
- c
c
O O
� o �/ o
i
w - �1 -- - -�-� - , � -- s
� o 0
0 0
b
b
�
'�'
..�arna�.� _
BERMAD FirE ProtECtion � �
' • • - • • � - • � - - 700 SEriEs
Installation
Proper operation of the 700E Deluge Valves depends In the SET position, the water pressure supplied through
upon their trim being installed in accordance with the the priming line is trapped in the upper control chamber
appropriate trim configuration. of the deluge valve by a check valve, and by the normally
Notes: closed release device.
■ Wet pilot height should not exceed "Maximum The pressure trapped in the upper control chamber of the
Elevation Above Valve" (see data for specific model). deluge valve presses the valve seal disk down, thereby
■ Any deviation in trim size or arrangement may
sealing the valve and keeping the system piping dry.
adversely affect the proper operation of the deluge Under conditions of FIRE, when the pressure is released
valve. from the upper control chamber by the opening of the
automatic releasing device or by manual release, the
■ All the pilot system devices, must be UL Listed and deluge valve opens and allows the inlet supply water to
compatible with the particular deluge system. flow through the valve and into the system piping and
Refer to current "UL Listed Fire Protection Equipment alarm devices.
Directory".
Warning: The deluge valve and trim must be installed Warning: Whenever the handle of the Manual Emergency
Release is pulled, pressure is released from the upper
only in areas where they will not be subject to freezing control chamber, the deluge valve will open, and water
temperatures. will flow into system piping and alarm devices.
Installation Instructions Electric
1. Allow enough room around the valve assembly for �Pneumatic
any adjustments and future maintenance. Hydrauiic
2. Before the valve is installed, flush the pipeline to
remove any dirt, scale, debris, etc. Not flushing the
line may result in the valve's becoming inoperable.
3. Install the valve in the pipeline so that the valve flow
arrow appearing on the body casting is pointing in the
desired direction. Ensure that the valve is positioned �;,
so that the actuator assembly can be easily removed _
for future maintenance.
4. Ensure that the Control Trim is mounted properly and �I
all other components are positioned correctly as per Valve Closed (Set Position)
illustration.
Line pressure applied to the upper control chamber
5. After installation in the main line, carefully inspect/ of the valve creates a superior force that moves the
correct any damaged accessories, piping, tubing, or valve to the closed position and provides drip tight
fittings. Ensure that there are no leaks. sealing.
6. Install the components comprising the Deluge Trim Electric
Package in their proper positions in compliance with Pneumatic
all instructions, drawings, and technical specifications Hydraulic
describing the BERMAD Deluge Valve, according to
the relevant illustration.
7. All additional accessories, although not packed
together with the BERMAD Deluge Valve, must be ;->�
installed as shown in the relevant P&ID and other ���
illustrations. ����' ���
Operation : "
Principle of Operation �
The BERMAD 700E Deluge Valve (assembled with specific Valve Open (Operating Conditions)
trim) is suitable for systems that include adequate
6 detecting and piping systems with open nozzles. The Releasing the pressure from the upper control
deluge valve prevents water from entering system piping chamber to atmosphere or some other lower
until required. The deluge valve is kept closed by pressure pressure zone causes the line pressure acting on the
applied to the upper control chamber through a restricted seal disc to move the valve to the open position.
priming line.
_�
��
_ ��
BERMAD FirE ProtECtion � �
' • • - - � • � - • � - - 700 SEriEs
Placing in Service/Resetting 5. The system should be checked weekly for "Normal
The deluge valve and the control trim shall be Placed in Conditions".
Service with accordance to the most recent IOM 6. Clean the priming strainer prior to any resetting of the
procedures for the specific model. deluge valve.
After all relevant instructions are performed, slowly open 7. The deluge valve must be activated at full flow at
the supply-isolating valve and check that no water flows least annually. Take all necessary precautions to drain
into the system. water and prevent damage in the area protected by
The system is now operational and in stand-by mode. the system.
8. After about five years of operation, replacement of
Maintenance diaphragm and other elastomers is recommended.
Remove the actuator and disassemble it. Clean the
Bermad Deluge Valves require no lubrication, no packing seat area from sediments, clean the control tubing
tightening, and require a minimum of maintenance. entry holes, and install a new diaphragm and other
elastomers in place.
Removing the System from Service
Warning: When taking a deluge system out of service, a
fire patrol should be established in the system area. If Spare Parts
automatic fire alarm signaling equipment is utilized, the 1. The Diaphragm and the Seals are the only spare parts
proper authority should be notified that the system is needed for the main deluge valve, see attached
being removed from service. The insuring body and
owner's representative should also be notified when the "Valve Disassembly and Parts Breakdown" illustration.
system is being taken out of service. 2. It is not recommended to store spare rubber parts for
long periods (rubber in improper storage conditions
can harden and crack).
Removal Instructions 3. Contact your Bermad representative and order new
1. Shut off the main supply-isolating valve. rubber parts when required.
2. Close the priming line valve to the deluge valve
control chamber.
3. Open all drain valves.
4. Release the water pressure from the control chamber
of the deluge valve by pulling the manual emergency
release.
5. Place "Fire Protection System Out of Service" signs in
the area protected by the system.
Inspection and Testing
1. Warning:Do not turn off the water supply to make
repairs without placing a roving fire patrol in the area
covered by the system. The patrol should continue
until the system is back in service.
2. Prior to turning off any valves or activating any
alarms, notify local security guards and the central
alarm station, if used, to avoid signaling a false alarm.
3. The deluge valve and the control trim shall be
maintained with accordance to the most recent IOM
procedures for the specific model. A periodic test
schedule should be established also with accordance
to the site conditions and owner regulations.
4. Take all additional measures as required by NFPA-25
"standard for the inspection, testing, and �
maintenance of water-based fire protection systems".
.�
'�'
.�R�1iA�,� _
BERMAD FirE ProtECtion � �
' • • - - • • � - • � - - 700 SEriEs
Valve DisassEmbling Parts Breakdown
Actuator Assembly
° a Cover Plug
(6"and up) �
� � O-Ring � � golt
Eye _
i
Nut ° ° Disk
0
o ° °
0 0
Cover
0 0
0
� Indicator Lock Nut
� I
Screw \ i � Nut
- Diaphragm Washer
Removable
Seat I � Spacer Disk
O �
�
0 o Diaphragm
� O-Ring
� o 0
o ° Diaphragm Washer
� � � 0 �
Shaft
� 0 � Bearing
Screw p
�_ Nuc o I �
� Disk 1
Y Body Type 0 � I � Bearing Assembly
Separation �
Partition o 0
° � ' � Seal Disk
o � o � Assembly
0
o Bolt — Nut °— O-Ring
� 0 Seal
Stud Disk
Q — Spring
o � 0 Seal
o� Q � -Seal
0 0 Disk
Wash.
8 � Nut �
� �_ Locking Screw
Angle Body Type screw
� bermadfire@bermad.com • www.bermad.com
� The information herein is subject to change without notice.BERMAD shall not be held
liable for any errors.All rights reserved. �O Copyright by BERMAD. PT7PE04-DATA
_ ��':
September 18, 2009 30a
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
1. DESCRIPTION
Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4", 1-1/2",2",2-1/2", 3",4",6"and 8"for commercial
systems.They are available with an AGF TESTanDRAIN valve, and/or pressure relief valve(PRV)to meet NFPA 13 requirements for
gridded systems and any system requiring a pressure relief valve. This configuration eliminates the need to drain the system before
installing the relief valve,while a built in test port allows hydrostatic testing without draining the system.
EasyPac Commercial Assemblies are designed with all required equipment and standard components that can be replaced in the field,
including pressure gauges, Potter flow switches,3-way gauge control valve and appropriate drain valve.All assemblies are available in
grooved inlet and outlet connections 1-1/4"-8" using Schedule 10 steel pipe. The 1-1/4"to 2"assemblies are also available with male
NPT threaded inlets and outlets, or threaded inlets x grooved outlets using Schedule 40 steel pipe.
2. LISTINGS AND APPROVALS
Pressure Gauges: UL Listed, FM Approved
Waterflow Alarm Switch: UL Listed-Category USQT, cUL Listed, FM Approved-Waterflow Detectors, Vane Type, CSFM Listed
Ball Valve: UL Listed, FM Approved
AGF TestanDrain Model 1000: UL Listed -Category VEHZ, FM Approved -Sprinkler System Alarm Testers
AGF TestanDrain Model 1011 with Pressure Relief Valve: UL Listed-Category VEHZ, FM Approved-Sprinkler System Alarm Testers
3. TECHNICAL DATA Viking Technical Data may be found on
Specifications and Material Standards: The Viking Corporation's Web site at
Available since 2007. http://www.vikinggroupinc.com.
• Pressure Rating: 250 PSI (172 bar)maximum water working pressure. The Web site may include a more recent
• Fabricated steel pipe. edition of this Technical Data Page.
• Available in grooved inlet and outlet connections 1-1/4"to 8"using Schedule 10 steel pipe.
• 1-1/4", 1-1/2", and 2" assemblies are also available with male NPT threaded inlet and outlet, or threaded inlet x grooved outlet
using Schedule 40 steel pipe.
• Riser bodies coated with black Ecoat.
• Flow Switch:Two single-pole double-throw switches with Form C contacts rated at 15 Amps 125/250 V.AC, 2.5 Amp 0-30 V. DC.
Each switch can be wired for open or closed circuit operation. See Figure 1.
Ordering Information:
(Also refer to the current Viking price list.)
There are three different options are available for the commercial line:
Commercial EasyPac Assemblies with Ball Valve(See figure 2)
Commercial EasyPac Assemblies with TESTanDRAIN Valve (See figure 3)
Commercial EasyPac Assemblies with TESTanDRAIN and Pressure Relief Valve(PRV)(See figure 4)
See Table 1 for Part Numbers.
4. INSTALLATION
Refer to appropriate NFPA Installation Standards.
Note: EasyPac Commercial Riser Manifold Assemblies can be installed horizontally with flow switch on top,or vertically with flow upward.
Viking EasyPac RiserAssemblies use Potter VSR flow switches.The literature that accompanies the VSR states that the switch should
not be installed within 6"of a change of direction of pipe or within 24"of a valve.This is merely a recommendation to reduce the pos-
sibility of the switch not operating while minimal waterflow is occurring.This is a recommendation only, not a requirement.
5. OPERATING INSTRUCTIONS
1. To Test:Turn valve handle counterclockwise from "Off°to"TesY'.The handle will stop automatically.After test is completed, return
handle to "Off'.
2. To Drain: Turn handle counterclockwise from "Off° to "Test". The handle will stop automatically. Depress "Push" button and turn
handle to"Drain". When system is empty, return handle clockwise to "Off° position.
6. INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection,Testing and Maintenance requirements.
Form No. F_102307 Replaces page 30a-f dated July 31, 2009. (Removed note regarding
the flow switch for Canada orders-now use the same flow switch.)
30b September 18, 2009
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Table 1 -Commercial EasyPac Assemblies TESTanDRAIN Ootion:
Includes a test orifice with size specified
Inlet/Outlet Viking Part from 3/8"(K2.8)to 25K ESFR",depending
Pipe Size Connections Option Pipe Size Number on the smallest sprinkler installed on the
Ball Valve 15248 system. Must add suffix to the part number
Thread/Thread TESTanDRAIN Schedule 40 14871 for the desired orifice size.
TESTanDRAIN and PRV 14873 Orifice Suffix:
Ball Valve 15249 A=3/8"(K 2.8)
B=7/16"(K 4.2)
1-1/4" Groove/Groove TESTanDRAIN Schedule 10 14872 C- 1/2"(K 5.6)
TESTanDRAIN and PRV 14874 D= 17/32"(K 8.0)
Ball Valve 15250 E=K 11.2 ELO
Thread/Groove TESTanDRAIN Schedule 40 15251 F=K14 ESFR
TESTanDRAIN and PRV 15252 G=K25 ESFR
Ball Valve 15253
Thread/Thread TESTanDRAIN Schedule 40 14875 TESTanDRAIN with PRV Option:
TESTanDRAIN and PRV 14877 Includes test orifice and pressure relief
valve.The test orifice must be specified
Ball Valve 15254 _ based on the smallest sprinkler installed on
1-1/2" Groove/Groove TESTanDRAIN Schedule 10 14876 the system for 3/8"(K2.8)to K25 ESFR".
TESTanDRAIN and PRV 14878 The pressure relief valve is not factory
Ball Valve 15255 assembled to the TestanDrain.Must add
Thread/Groove TESTanDRAIN Schedule 40 15256 suffix to the part number for the desired
TESTanDRAIN and PRV 15257 orifice size and pressure setting of the
Ball Valve 14899 pressure relief valve.
Orifice Suffix:
Thread/Thread TESTanDRAIN Schedule 40 14935
- A=3/8"(K 2.8)
TESTanDRAIN and PRV 14847 g=7/16"(K 4.2)
Ball Valve 14848 C= 1/2"(K 5.6)
2" Groove/Groove TESTanDRAIN Schedule 10 14850 D= 17/32"(K 8.0)
TESTanDRAIN and PRV 14851 E=K 11.2 ELO
Ball Valve 15258 F=K14 ESFR
Thread/Groove TESTanDRAIN Schedule 40 15259 G=K25 ESFR
TESTanDRAIN and PRV 15260 PRV Suffix:
175
Ball Valve 14852 185
2-1/2" Groove/Groove TESTanDRAIN Schedule 10 14853 195
TESTanDRAIN and PRV 14854 205
Ball Valve 14855 225
3" Groove/Groove TESTanDRAIN Schedule 10 14856 250
TESTanDRAIN and PRV 14857 NOTE: It is important to note that the
Ball Valve 14858 pressure rating of the relief valve indicates
an operating range of pressure for both
4" Groove/Groove TESTanDRAIN Schedule 10 14859 opening and closing of the valve.Standard
TESTanDRAIN and PRV 14860 relief valves are required to OPEN in a
Ball Valve 14861 range of pressure between 90°/o and 105%
6" Groove/Groove TESTanDRAIN Schedule 10 14862 of their rating.The valves are required to
TESTanDRAIN and PRV 14863 CLOSE at a pressure above 80%of that
Ball Valve 15264 rating.
8" Groove/Groove TESTanDRAIN Schedule 10 15265 *ESFR TESTanDRAIN not available in
TESTanDRAIN and PRV 15266 1-1/4", 1-1/2"or 2"Risers.
Table 2- Pipe Diameters
I 1-1/4" 1-1/2" I 2" 2-1/2„ 3„ 4„ 6„ 8„
Pipe OD 1.660" 1.900" 2.375" 2.875" 3.5" 4.5" 6.625" 8.625"
(42 mm) (48 mm) (60 mm) (73 mm) (89 mm) (114 mm) (168 mm) (219 mm)
Schedule 10 Pipe ID I 1.45" 1.69" 2.16" 2.64" 3.26" 4.26" 6.36" 8.249"
(36.6 mm) (42.7 mm) (54.8 mm) (66.9 mm) (82.8 mm) (108.2 mm) (161.5 mm) (209.5 mm)
Schedule 40 Pipe ID 1.38" 1.61" 2.07"
N/A N/A N/A N/A N/A
(35.1 mm) (40.9 mm) (52.5 mm)
September 18, 2009 30c
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
7. AVAILABILITY
The Viking EasyPac Riser Assemblies are available through a network of domestic and international distributors. See The Viking Cor-
poration web site for the closest distributor or contact The Viking Corporation.
8. GUARANTEE
For details of warranty, refer to Viking's current list price schedule or contact Viking directly.
BE��
❑R
H�RN Eo�R
�
�
�
_ N0 � To auxiliary
annunciator
° NC ° or control
+ COM when requirea'
Figure 1 -Flow Switch with Two Single Pole,
Double Throw Micro Switches
30d September 18, 2009
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
F �H�
V06�B��
� �
���
���
C
WATER i D
FLOW
A
� �
�
E B
G I
Figure 2-Basic Commercial EasyPac
Size A B C D E F G H I
1-1/4" (DN32) VSR-S Flow Switch 1"NPT 16-1/2" 15" 1-1/2" 6-3/32" 6-11/32" 4-3/16" 8-9/16"
(419) (381) (38) (155) (161) (107) (218)
1-1/2" (DN40) VSR-S Flow Switch 1"NPT 16-1/2" 15" 1-1/2" 7-19/32" 6-15/16" 5-11/16" 10-1/16"
(419) (381) (38) (193) (164) (144) (256)
2" (DN50) VSR Flow Switch 1"NPT 14-1/2" 13" -15/32" 6-7/16" 5-51/64" 4-9/16" 8-59/64"
(369) (330) (12)" (164) (148") (116) (227)
2-1/2" (DN65) VSR Flow Switch 1-1/4"NPT 14-1/2" 13" 5/8" 6-11/16" 6-3/64" 5-1/4" 9-39/64"
(369) (330) (16) (170) (154) (133) (244)
14-1/2" 13" 5/8" 7" 6-23/64" 5-9/16" 9-59/64"
3" (DN80) VSR Flow Switch 1-1/4"NPT (369) (330) (16) (178) (162) (141) (252)
4" (DN100) VSR Flow Switch 2"NPT 14-1/2" 13" -1-3/4" 7-1/2" 6-25/32" 7-3/4" 13-5/16"
(369) (330) (-44)` (191) (173) (197) (338)
6" (DN150) VSR Flow Switch 2"NPT � 14-1/2" 13" -1-3/4" 8-35/64" 7-53/64" 8-51/64" 14-23/64"
(369) (330) (-44)' (217) (199) (223) (365)
8" (DN200) VSR Flow Switch 2"NPT 14-3/4" 13" -1-3/4" 9-1/2" 8-3/4" 9-3/4" 15-1/2"
(375) (330) (-44)' (243) (225) (249) (391)
"Dimension E is negative because the ball valve extends below the end of the manifold body.
September 18, 2009 30e
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
F H
vo�o��
—
i
i
i
��� - - - — II
�e� I
i
i
C I ��o p
i0 ° ° — --
�� ——— � � TESTaN DRAIN �
o —
A I� _ �
li � �
... �
� � B
�
I E I
G I
Figure 3-Commercial EasyPac with TESTanDRAIN
Size A B C D E F G H I
1-1/4" (DN32) VSR-S Flow Switch 1"NPT 16-1/2" 15" 5-1/8" 6-3/32" 6-11/32" 4-1/2" 9-3/32"
(419) (381) (131) (155) I (161) (114) (231)
1-1/2" (DN40) VSR-S Flow Switch 1"NPT 16-1/2" 15" 5-1/8" 7-19/32" 6-15/16" 4-3/4" 9-7/32"
(419) (381) (131) (193) (164) (121) (234)
2" (DN50) VSR Flow Switch 1°NPT �4-1/2° 13° 3-1/16" 6-7/16" 5-51/64° 4-49/64" 9-35/64"
(369) (330) (78) (164) (148") (121) (242)
2-1/2" (DN65) VSR Flow Switch 1-1/4"NPT 14-1/2" 13" 3-1/4" 6-11/16" 6-3/64" 6-1/4" 10-61/64"
(369) (330) (83) (170) (154) (159) (278)
3" (DN80) VSR Flow Switch 1-1/4"NPT 14-1/2" 13" 3-1/4" 7" 6-23/64" 5-5/8" 11-17/64"
(369) (330) (83) (178) (162) (143) (286)
4" (DN100) VSR Flow Switch 2"NPT 14-1/2" 13" 2-5/8" 7-1/2" 6-25/32" 8-3/16" 16-3/8"
(369) (330) (66) (191) (173) (208) (416)
6" (DN150) VSR Flow Switch 2"NPT 14-1/2" 13" 2-5/8" 8-35/64" 7-53/64" 9-15/64" 17-27/64"
(369) (330) (66) (217) (199) (235) (443)
8" (DN200) VSR Flow Switch 2"NPT 14-3/4° 13" 2-3/4" 9-1/2" I 8-3/4" 10-1/4" 18-1/2"
(375) (330) (70) (243) (225) (262) (468)
30f September 18, 2009
o EASYPAC COMMERCIAL
1 � � � � RISER MANIFOLD
�� ASSEMBLIES
1-1/4°-8" (DN32- DN200)
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
F H
�o�o��
�
��� C�� I�I�
���
WATER
�' FLOW ��o D
� o � �m TESTAN�RAiN ] "�NOTE: PRESSURE
o RELIEF VALVE KI
' e IS SHIPPED LOOSE.
IT IS NOT FACTORY
A� � —� III� � INSTALLED.
�
�
1 ° B
�
D
E
- G� - I -
Figure 4-Commercial EasyPac with TESTanDRAIN and PRV
Size A B C D E F G H I
1-1/4" (DN32) VSR-S Flow Switch 1"NPT 16-1/2" 15" 5-1/8" 6-3/32" 6-11/32" 4-1/2" 9-3/32"
(419) (381) (131) (155) (161) (114) (231)
1-1/2" (DN40) VSR-S Flow Switch 1"NPT 16-1/2" 15" 5-1/8" 7-19/32" 6-15/16" 4-3/4" 9-7/32"
(419) (381) (131) (193) (164) (121) (234)
2" (DN50) VSR Flow Switch 1"NPT 14-1/2" 13" 3-3/16" 6-7/16" 5-51/64" 5-13/64" 10-45/64"
(369) (330) (81) (164) (148") (132) (272)
2-1/2" (DN65) VSR Flow Switch 1-1/4"NPT 14-1/2" 13" 3-1/4" 6-11/16" 6-3/64" 6-1/4" 10-61/64"
(369) (330) (83) (170) (154) (159) (278)
3" (DN80) VSR Flow Switch 1-1/4"NPT 14-1/2" 13" 3-1/4" �„�178� 6-23/64" 5-5/8" 11-17/64"
(369) (330) (83) (162) (143) (286)
4" (DN100) VSR Flow Switch 2"NPT 14-1/2" 13" 2-5/8" 7-1/2" � 6-25/32" 8-3/16" 16-3/8"
(369) (330) (66) (191) (173) (208) (416)
6" (DN150) VSR Flow Switch 2"NPT 14-1/2" 13" 2-5/8" 8-35/64" I 7-53/64" 9-15/64" 17-27/64"
(369) (330) (66) (217) (199) (235) (443)
8" (DN200) � VSR Flow Switch 2"NPT �4-3/4° 13" 2-3/4° 9-1/2" 8-3/4" 10-1/4" 18-1/2°
(375) (330) (70) (243) (225) (262) (468)
Form No. F 102307 Replaces page 30a-f dated July 31, 2009. (Removed note regarding
the flow switch for Canada orders-now use the same flow switch.)
.
_,:•� :.. . _ � •
U� FM
ISEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
SERIES 722
Series 722 Ball Valve is a standard port,female threaded end valve designed for up to =
600psi/4135kPa (WOG)service.Valve body is constructed from forged brass. The ball is a��
chrome plated brass and seals on TFE seats. ,,R -
A hollow ball design eliminates unnecessary weight while maintaining flow and � � �
mechanical strength.TFE seats and washers reduce the friction coefficient which eases 1 �
valve operation. : : y
Valve sizes'/z"/15mm and above are UL Listed at 175 si/1200kPa and FM A roved at �
P PP ---��.---
600psi/4135kPa for'/z'Y15mm and 3/a'Y20mm sizes and 500psi/3450kPa for 1-2"/25
-50mm sizes.
DIMENSIONS
� .
I` F `I
� i Ya 0.540 1.54 OJ7 1.03 1.65 � 0.2
8 13J 39 20 26 42 0.09
� '/s 0.675 1J7 0.88 L28 3.07 � 03
� 10 17.1 45 2Z 33 78 0.14
'/z* 0.084 2.13 1.06 133 3.07 �� 0.4
__ _ 15 �13 54 27 34 78 0.18
i '/a* 1.050 2.44 L22 1J9 3J8 ZS OJ
20 26J 62 31 45 96 03Z
��B 1* 1315 295 1.48 1.95 3J8 3� 1.0
25 334 75 37 50 96 045
�f A � 1 Ya* 1.660 331 1.65 2.17 3J8 50 1.5
3Z 422 84 42 55 96 0.68
1'/z* 1.900 3.66 1.83 2.68 5.43 8� 2.1
40 483 93 46 68 138 0.95
Z* Z375 4.Z1 2.11 2.89 5.43 ��� 2.4
50 603 107 53 73 138 1.09
x UL Listed,FM Approved as noted in text above.
PERFORMANCE C�values for flow of water at+60°F/+16°C are shown in the table above.
�P = Q' Where:
�� Q=Row(GPM)
� �P=Pressure Drop(psi)
Q = C„ x 4P C�=Flow Coefficient
JOB OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.a`�lJI1C�
REV_C OF3.15_1
_. .� .�• � _ � :
U� FM
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS •
SERIES 722
�
.�.
g�. i � �.
�� �. :
�_, --_
MATERIAL SPECIFICATIONS Body: Forged Brass ASTM B-16
Ball: Brass ASTM B-16,chrome plated
Stem: Brass ASTM B-16, chrome plated
Seats: (TFE)Tetrafluoroethylene, rated to+450°F/+232°C
Handle: Carbon steel,zinc plated
Stem Nut:Carbon steel,zinc plated
Stem Washer: (TFE)Tetrafluoroethylene
0-Ring: Fluoroelastomer
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the
right to change product specifications,designs and standard equipment without notice and without
incurring obligations.
VV£��I=€7 3°^.�,�L��PJ�M627�Ed� �:t�4v"�, +b� t;`v-.�. `� �".'_;SK�U�'!-!AfMIERICA
P.O. Box 31 905-884-7444 1-610-559-3300
Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax)
4901 Kesslersville Road viccanada@victaulic.com vicai@victaulic.com
Easton, PA 18040 USA
EUr�6PE ���A PpCiFiC
1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-58855151
1-610 559-3300 32-9-380-44-38(fax) 86-21-58851298(fax)
1-610-250-8817(fax) viceuro@victaulic.be vicap@victaulic.com
pickvic@victaulic.com
9Jhi MICbC�Lti ?'«,iu
_;i'�Ji�i'",�?S�it�'i�E� �������������������������������������������
1-800-PICK-VIC(1-800 742-5842) 44(0) 1438741100 971-4-883-88-70
44(0) 1438313883(fax) 971-4-883-88-60(fax) WCAS-6HXL4R
1-610-250-8817(fax) viceuro@victaulic.be
pickvic@victaulic.com www.victaulic.com
UPDATED 2/06
08.15 1669 REV C I C.t'ca�,1�1�+�
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA.
�,�.�5
.
_.:•� . :. .� _ � � .
U� FM U�C vds LPCB
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
SERIES 7ll
,�"�.t.._�;„ ��Y
Series 717 FireLock check valve is a CAD-developed design that is hydrodynamically efficient. �
A totally rubber encapsulatetl tlisc on 4-12"/100-300mm sizes provitles superior corrosion ' ` '
r e s i s t a n c e. T h i s s i n g f e d i s c d e s i g n i n c o r p o r a t e s a s p r i n g a s s i s t e d f e a t u r e f o r n o n-s l a m m i n g � ���• •-
operation. For systems requiring a Riser Check option refer to section 10.09. �� �!'
;�iy.._ - ' �'-.,. ,
The 4"/100mm and larger sizes are provided with upstream and downstream drains and � � --
a welded-in nickel seat design.All sizes of Series 717 can be installed in the vertical or ;,�,
horizontal position to provide leak free sealing under conditions as low as five feet of head. =-�-.
Each valve Is factory tested to 500psi/3440kPa. The 2'/z and 3"/65 and 80mm sizes are UU
ULC Listed and 4"/100mm sizes and larger are UL/ULC Listed and FM Approved for services
up to 250 psi/ll25 kPa. Sizes 4-8"/100-200 mm (except 165.1 mm size)are VdS approved.
Grooved ends allow fast,easy installation with just two Victaulic couplings or the valve may be
mounted to flanged (ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flange°
or Style 744 FireLock flange adapters on either end.
DIMENSIONS
�
�< A >� <� B �
OO �'
C 2'/� 2.875 3.SS 4.26 3.57 3.6
�, 65 73.0 99 108 91 16
TYPICAL 2'h-3"/65-80 MM 76.1 mm 3.000 3.SS 4.26 3.57 3.6
76.1 99 108 91 1.6
F � y 3 3.500 4.25 5.06 4.17 4.5
�R I� ��� 80 88.9 108 129 106 2.0
� �, 4 t 4.500 9.63 6.00 3.88 2J5 3.50 Z.00 4.50 3.50 335 Z0.0
y� P C 100 1143 245 152 99 70 89 51 114 89 85 9.1
I�� � --- '��- 5 t 5.563 1Q50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0
�� D E 125 1413 267 173 114 106 55 149 104 101 1z3
W 5.500 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0
�K�� � ��� 139Jmm t �39J 267 173 114 106 55 149 104 101 123
�B �I J IF �
6 t 6.625 11.50 8.00 5.00 4.50 238 6.67 4J3 3.89 38.0
� '/z"NPT Upstream Drain 150 1683 292 203 127 114 61 169 120 99 172
� Yz"NPT Downstream Drain
� 2"NPT(Drain Optional) 165.1 mm 6.500 11.50 8.00 5.00 4.50 Z38 6.67 4J3 3.89 38.0
165.1 292 203 127 114 61 169 120 99 17.2
TYPICAL 4-S"/100-200MM g h 8.6Z5 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 SJS 64.0
200 219.1 356 Z51 154 128 144 55 225 144 146 29.0
-E A�
10 10750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6J3 100.0
�� � � 250 273.0 43� 305 l80 151 170 55 277 171 45.4
P C
� _ _ _ � 12 12J50 19.50 14.00 8.06 6.91 7.64 2.51 12.81 7J3 140.0
� � ? 300 323.9 495 356 ZOS 176 194 64 925 196 63.5
D E
I` K � Z Y� t VdS Approved
< g - ->J<-
1�Yz"NPT Upstream Drain
��/z"NPT Downstream Drain
TYPICAL 10-12"/250-300 MM
JOB/OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
WWW.VICTAULIC.COM
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.a`�lJI1C�
Va".3" ' .`r .'i.:'�A '°�" C-_�.. V��'�_ .. �j-�r_I� ['1�t��°0 [:�'`�' a �. .. ����V
�rPP�;� sw,�+�i\±�l ��,,s+,s�Ir,r �;IiR�A.�f�^n!`
SERIES 717
MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM
A-395,grade 65-45-15, is available upon special request 2'/z—3"/65—80mm sizes PPS coated.
4—12"/100—300mm sizes painted black enamel.
Body Seat: 2�/z—3"/65—80mm sizes PPS coated.4—12"/100—300mm integrally welded on
nickel alloy.
Disc Seal or Coating:
• Grade"E" EPDM
EPDM (Green color code). Temperature range—30°F to+230°F/-34°C to+110°C.
Recommended for cold and hot water service within the specified temperature range plus a
variety of dilute acids, oil-free air and many chemical services. UL dassifietl in accordance
with ANSI/NSF 61 for cold +86°F/+30°C and hot+180°F/+82°C potable water service. NOT
RECOMMENDED FOR PETROLEUM SERVICES.
� Services listed are General Service Recommendations only. It should be noted that there are
services for which these gaskets are not recommended. Reference should always be made to
the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a
listing of services which are not recommended.
Discs:
• 2�/z—3"/65—80 mm Aluminum bronze conforming to ASTM B-148 with Grade "E"Seal.
• 4—12"/100—300 mm ductile iron conforming to ASTM A-536,grade 65-45-12,fully
encapsulated in Grade "E" elastomer.
Shaft: 21/z—3'Y65—80mm Type 416 stainless steel.4—12"/100—300mm Type 316 stainless steel.
Spring: All sizes Type 302/304 stainless steel.
Shaft Plug: 2�/z—3"/65—80 mm only; SAE Hex Socket Type conforming to ASTM A-576, cadmium
plated to military specifications QQ-P-416A, class 3 type 2.4— 12"/100—300 mm only;carbon
steel zinc plated to ASTM B-633.
Pipe Plug:4—12"/100—300mm only; carbon steel zinc plated to ASTM B-633.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED W THE USA. �CtaLII1C�
,���� �r��,�,���� :�:�€.�� �.,�at. . ,� � ��z,�,� �������� ������� 10.08
���.�� �,,,�►�,�C� �,�'�ca���,� �A��s�m��
SERIES 717
FLOW CHARACTERISTICS NOTE: Placement of check valves too close to sources of unstable flow will shorten the life of
the valve and potentially may damage the system.To extend valve life,valves should be installed
a reasonable distance downstream from pumps,elbows,expanders, reducers or other similar
devices. Sound piping practices dictate a minimum of five(5)tlmes the pipe diameter for general
use. Distances between three(3)and five(5)diameters are allowable provided the flow velocity
is less than eight(8)feet per second (2.4 mps). Distances less than three(3)diameters are not
recommended and will violate the Victaulic product warranty.
The chart below expresses the flow of water at 65°F/18°C through a full open valve.
6.0
5.0
4.0
3.0 FF ^F`� F`�
^b ^q. ^'
'`n 2.0 � ,
a� a�
? ,�; ;;� a y � �i ° ,�1'
a
� 0.9
� O.S
w 0.7
� 0.6
y 0.5
yNj 0.4
�
a 03
0.2
0.1
10 20 30 40 5060 80100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000
800 3,000 8,000
FLOW RATE—G.P.M.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �CtaUI1Cc
�u.vo �
,:. , � � :
_ ► ':• •� -
SERIES 717
INSTALLATION Reference should always be made to the I 100 Victaulic Field Installation Handbook for the product
you are installing. Handbooks are included with each shipment of Victaulic products for complete
installation and assembly data,and are available in PDF format on our website at www.victaulic.com.
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the
right to change product specifications,designs and standard equipment without notice and without
incurring obligations.
III II II I III I III IIIIIIIII IIIII III IIIIIIII III
WCAS-6Y9KNU
For complete contact information,visit www.victaulic.com
10.08 1479 REV G UPDATED 2/2007 �Ct'c�UI1C�
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA.
PO���� LOS ANGELES AREA (800)366-3473
NEW YORK AREA (800)526-4592
ROEMER CHICAGO AREA (800)547-3473
ATLANTA AREA (800)762-0542 Call Potter Roemer for current listings and approvals.
FIREPROT1EC170NEd�UIP1VENT MIAMI AREA (866)961-3473 Dimensions are subject to manufacturer's tolerances,
DALLAS AREA (866)664-3473 and change without notice. We assume no responsi-
bility for use of superseded or void data.
�� EXPOSED FIRE DEPT. �
° INLET CONNECTION APPROVED
TWO-WAY WITH SINGLE CLAPPER
❑ Model 57'10-A-DI TOP VIEW �_
Back Outlet Shown with ID Plate � ��Q , Sp�
4 x 2-1/2 NPT x NST Mode15962 /� � 9 ��
(sold separately) �
1 1
I � � �
�
\ � t� �
Pipin �� �� �
(by others� �� 4" Female
REGULARLY ID Plate � NPT Threads
FURNISHED: Model 5962
Ductile iron two-way inlet (sold separatelyc� — � �
body painted red, swing clapper � � 45°�
and brass pin lug swivel. �
Lettering:AUTO. SPKR. � ,,,
Pressure Rating: 300 psi (2,067 kPA) . i . . .
Compliance: UL Listed, FM Approved 2-��2"
S ecial Thread Available Female NST
p Threads ,
(Brass Swivel)
Specify Thread: BOTTOM VIEW TOP VIEW
❑ Model57'15—A—DI
Angle Outlet / / T\
4 x 2-1/2 NPT x NST \
°r,o
� �
� � �
FRONT VIEW . � - I
Shown with ID Plate a� I
Model 5962 �
(sold separately) � �
9� � .
2-1/2
Female NST
REGULARLY Threads
FURNISHE�: (Brass swivel) �
Ductile iron two-way inlet
body painted red, swing clapper ��
and brass pin lug swivel. . .
Lettering:AUTO. SPKR. �� 900
Pressure Rating: 300 psi (2,067 kPA) �
Compliance: UL Listed, FM Approved
Special Thread Available Piping
SIDE VIEW 4" Female �byothers)
Specify Thread: NPT Threads �
Revised Reviewed � �R""�""'� � � MODEL NUMBER
6/23/08 6/23/08 MEMBER OF: ap�a � � � �
►r�o�cu�rc�.r� i � �
NFR�i6� � ♦ �
� �
� � � � �
� � f ,��,
�'.
� �
�. ��
''.�
�
�
" '"�
y
w
�. '-�
�
�
�
.�f;
*, :�
.}
� '
��i°.
w:,
.�
r
�
��F .
.��
•-^r
, ��
�
Wirh A8F
Protection
, , , ,
Schedu 1e-10° Schedu 1e-40°
Fully Listed and FM Approved Sprinkler Pipe
When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product.Although these
products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand.
Our Sch-10 (1'/4"-8")pipe and Sch-40 (1"-2'/z")pipe have passed the same thorough lab testing as our other listed pipe
products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.
- � � - � � - �
NPS Naminal I.D. Wt. Wi.(H20 Filled) Pcs/ W1ILif1(21') Wt/Liit(24') WtlLift(25')
Schedule-10/Schedule-40 product can be In;mm In;mm Lbs/Ft,Kg/m Lbs/Ft,Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
"hot-dip"galvanized to meet FM
requirements for dry systems in 1�� 1.049 1.680 2.05 70 2,470 2,822 2,940
accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334
specifications of ASTM A-123. 1'�4" 1.380 2.270 2.93 51 2,431 2,778 2,894
32 35.1 4.36 4.36 51 1,103 1,260 1,313
• . � � • 1,/z" 1.610 2.720 3.61 44 2,513 2,872 2,992
40 40.9 4.0 5.37 44 1,140 1,303 1,357
Our advanced formula mill coating of- 2° 2.067 3.650 5.13 30 2,300 2,628 2,738
fers a clean, durable surface. It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242
paint-ready for custom colar applications 2Y2�� 2.469 5.790 7.86 19 2,310 2,640 2,750
without special preparation. 65 62J 8.6 11.73 19 1,048 1,197 1,247
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
� . - �
products up to 4.5000"in diameter is
coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wi.(H20 Filletl) Pcs/ W1ILif1(21') Wt/Lift(24') Wt�Lift(25')
mula,"ABF". In scientific laboratory In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft,Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
test,ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185
tance to microbial colonization of pipe 25 27.9 2.1 2J0 91 1,213 1,385 1,445
walls,thereby delaying or possibly pre- 1'/a" 1.442 1.810 2.52 61 2,319 2,664 2,760
venting the onset of Microbiologically 32 36.6 2J 3J5 61 1,052 1,208 1,252
Influenced corrosion(MIC)when the 1y2�� 1.682 2.080 3.04 61 2,664 3,045 3,172
First Sprinkler System is first installed. 40 42J 3.1 4.52 61 1,208 1,381 1,439
, , 2" 2,157 2.640 4.22 37 2,051 2,344 2,442
50 54.8 3.9 6.28 37 930 1,063 1,108
Meets `Buy American"requirement 2y2° 2.635 3.530 5.89 30 2,224 2,542 2,648
and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201
the USA, Canada and Mexico. 3�� 3.260 4.330 7.94 19 1,728 1,975 2,057
. - � � . . �
80 82.8 6.4 11.82 19 784 896 933
4" 4.260 5.610 11.78 19 2,238 2,558 2,665
Schedule-]0/Schedule-40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209
compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943
125 134.5 11.56 25.80 10 740 846 881
ASTM A-135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322
products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053
of 300 psi maximum and also meet the g" 8.249 16.490 40.15 7 2,424 2,770 2,885
stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309
tests:
•Welded Outlets �� FM ���
• Hydrostatic Pressure Listed Approved Listed
• Side Wall Rupture
•Vibration Test
�' CO FlowControl � ' 16100 S. Lathrop • Harvey, IL 60426 Customer Service:
y / \�l �Il1e� 11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543
TUBE&CONDUIT 2525 N. 27 th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S5 - 3
Return Previous Next Contents
�� �
�I � _z
y
I
�
.�
i I
I
;
ti
i
I �h
i
i
� 1 � �I
�
r
�
- �.�;..
_ ,
, ft
�
With ABF
Protection
0
, • /
Return Previous Next Contents
D na-Flow�
y
High Strength Steel Pipe
The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10.
Dyna-Flow pipe is tbe "original" high-
. - �
strength lightwall sprinkler pipe. Dyna-
Flow has outstanding hydraulic NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ WtlLift(21') Wt/Lift(24') WtlLift(25')
capabilities and is recognized as the �n;mm In;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg
mostpopular alternative to Schedule-l0 1" 1.191 0.830 1.31 91 1,586 1,812 1,888
pipe. Lightweight, easy to cut and easy 25 30.3 12 1.95 91 719 822 856
to handle for installation. Dyna-Flow is a 1 Ya" 1.536 1.059 1.87 61 1,356 1,550 1,615
valuable addition to any fire protection 32 39.0 1.6 2J8 61 615 703 733
system. 1'/z" 1 J28 1.667 2.71 61 2,135 2,440 2,542
� - � �
40 43.9 2.5 4.03 61 968 1107 1153
2" 2,203 2.104 3.79 37 1,634 1,868 1,946
With an inside diameter of up to 11% 50 56.0 3J 5.64 37 741 847 883
larger than Schedule-40 and up to 7% 2,/z" 2.703 2.564 5.10 30 1,615 1,846 1,923
larger than Schedule-10, Dyna-Flow 65 68J 3.8 7.59 30 733 837 872
pipe hydraulics are exceptional. Larger 3" 3.314 3.387 7.18 19 1,351 1,544 1,608
LD.s enable Dyna-Flow, and related 80 84.2 5.0 10.69 19 613 700 729
components,to be down-sized within the q�� 4.310 4.473 10.86 19 1,784 2,039 2,124
system,thus increasing the potential for g0 109.5 6.7 16.16 19 809 925 963
job cost savings. For complete Hazen-
Williams charts,refer to "Dyna-Flow
Hydraulic Data Tables."
� . . . � � . • � � � . � � . � �
Dyna-Flow products are coated with Dyna-Flow/Super Flo pipe is manufac- • Lightweight and easy to install,
an environmentally approved and tured to meet ASTM A-795 Type E, resulting in more efficient use of your
specially formulated modified-acrylic or Grade A and is in compliance with freight and labor dollars.
water-based coating. This durable coating NFPA-13 and NFPA-14.All sizes of
is paintable. Tbe black coating acts as Dyna Flow/Super Flo are UL Listed,FM ' Provides stabilily needed to comply
an excellent primer and is resistant to Approved and ULC Listed. with standard hanger spacing
(15 ft O.C.)per NFPA.
weathering and U.V. degradation from
outdoor storage. �� FM ��� • Available in Standard lengths for your
convenience, ar can be ordered in
Metallurgical properties provide excellent Listetl Approved Listed custom lengths upon approval.
fabrication characteristics for end prep Dyna-Flow/Super Flo is UL/ULC Listed
finishes,welding and roll grooving. for use with roll grooved,plain-end • Fast cutting and welding, as well as
There is no special process ar equipment couplings, and welded joints for wet, dry, easy roll grooving and end preparation.
needed for fabrication and installation. preaction and deluge systems. it is FM
• Available in Factory roll grooved form
The internal surface of all black Allied Approved for roll grooved, plain-end,and for quicker shop turnaround.
Tube & Conduit Fire Sprinlder pipe welded joints for wet systems. Refer to
products up to 4.5000"in diameter is appropriate documentation for up-to-date • Clean, durable mill coating provides
coated with our new Antibacterial ]isting and approval information. Dyna- longer"shelf life"and acts as an
Formula, "ABF". In scientific laboratory Flow/Super Flo is now available "hot- excellent primer for custom paint
test,ABS proved to have superior dip"galvanized and has been specifically applications.
resistance to microbial colonization of approved by FM for dry systems uses.
pipe walls,thereby delaying or possibly
preventing the onset of Microbiologically
Influenced corrosion (MIC)when the
First Sprinkler System is first installed.
�' CO FlowControl � ' 16100 S. Lathrop • Harvey, IL 60426 Customer Service:
y / \�l �Il1e� 11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543
TUBE&CONDUIT 2525 N. 27 th Ave. • Phoenix,AZ 85009 Fax 708-339-1806
S2 - 3
� � �
The Cost Effective Replacement for Schedule 10
Realizing the growing need of fire protection systems systems with a working pressure of 300 psi or less.
in commercial and residential construction, Bull Please check with appropriate sources for up-to-date
Moose Tube has added Eddy Flow to its listings and approval information.
comprehensive line of sprinkler pipe products.
As an added benefit, it is more economical to use than
Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease
schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID
providing design flexibility. This product is FM provides an opportunity for downsizing and further
approved, as well as UL listed (for U.S. and Canada) cost savings.
for roll grooving and welding for use in fire protection
COMPARISON
�i��u��d����t_a►��We���. °
• _•- -, , - .- ,...r -� -, n �-..- - ,�,A
1 1/4 1.660 1.530 1.442 1.380 1.98 1.00
1 1/2 1.900 1.728 1.682 1.610 3.44 1.00
2 2.375 2.203 2.157 2.067 2.78 1.00
2 1/2 2.875 2.705 2.635 2.469 1.66 1.00
3 3.500 3.334 3.260 3.068 1.00 1.00
4 4.500 4.310 4.260 4.026 1.00 1.00
" Corrosion Resistance Ratio
BENEFITS
• Dual Certified to ASTM A135 and A795.
. FM Approved for roll grooved,and welded,and plain-end application in wet systems.
. UL Listed(for U.S.and Canada)for joining by welding or by listed rubber gasketed fittings for use in wet,dry,
preaction,and deluge type sprinkler systems.
• UL Listed(for US and Canada)and FM Approved for use with Victaulic°FIT°Fittings in plain end applications.
• Lightweight-saves shipping costs,and offers easier handling.
. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi.
• Floor stock available in various lengths produced in Casa Grande(AZ), Gerald(MO),and Masury(OH).Also can be
ordered in custom lengths..
• Can be used for wet and dry*systems.
`Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems.
PIPE PREPARATION
For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be
free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior
to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's
instructions for the specific fitting used.
� � 1819 Clarkson Road For additional information, C �L US `'��
Chesterfield, MO 63017 contact your salesperson today at usTEO r
J � BULL MOOSE TUBE COMPANY �800)325-4467 (800)325-4467 or(636)537-2600
�,) FAX: (636)537-2645 in the USA,orfrom Canada FM
www.bullmoosetube.com call(800)882-4666
q CAPA O company e-mail:sales(cr�bullmoosetube.com APPROVED
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.
8/08
• • - . • � 1
A Lightweight Schedule 40 Replacement Pipe
That Has a Corrosion Resistance Ratio of 1.0
Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe
products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our
customers have an option to buy a carefully designed replacement for Schedule 40 that:
• Has a Corrosion Resistance Ratio of 1.0
• Has a Pressure Rating of 300 psi
• Is Lighter Weight Than Schedule 40
• Is Approved by Factory Mutual and Listed by Underwriters Laboratories
• Is Produced in Accordance to ASTM A-135 and A-795
• Can be Used With Standard Schedule 40 Threaded Fittings,
Couplings and Valves
• Is Produced From Steel With Excellent Properties of
Strength and Threadability
• Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems*
• Offers Lower Freight Costs
EDDYTHREAD 40 SPECIFICATIONS
1 1.461 1.083 70
1 1/4 2.070 1.418 51
1 1/2 2.547 1.654 44
2 3.308 2.123 30
CORROSION RESISTANCE RATIOS
!■►L!'l=� �
1 1.00 1.00
1 1/4 1.00 1.00
1 1/2 1.00 1.00
2 1.00 1.00
`Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems
� � 1819 Clarkson Road For additional information, C �L US ��
Chesterfield, MO 63017 contact your salesperson today at �
BULL MOOSE TUBE COMPANY
(800)325-4467 (800)325-4467 or(636)537-2600 usTEO - --- --
FAX: (636)537-2645 in the USA,or from Canada
www.bullmoosetube.com call(800)882-4666 FM
A CAPA� company e-mail:sales(c�bullmoosetube.com
APPROVED
All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.
8/08
= • - • • - • � 10.03
VICTAULIC"'IS AN ISO 9001 CERTIRED COMPANY
FireLock° Fittings
PRODUCT DESCRIPTION
FireLock°products comprise a unique system specifically designed forfire protection services.FireLock
� full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end
� dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain
� ' similar flow characteristics as standard full flow fittings.
FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings.Use of
other couplings or flange adapters may result in bolt pad interference.
Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005
couplings.
�
' Patented
�
1 '� U� U�C
� _ FM
See Victaulic
_ � �' � publication 10.01
for details.
�r,.�
DIMENSIONS
�-C to E� No.001 No.003 No.002 No.006
' �, Fitting Size 90°Elbow 45°Elbow Straight Tee Cap
,� C to E�� Actual Aprx. Aprx. Aprx. Thickness Aprx.
� ' �x ] � � Nominal Outside C to E Weight C to E Weight C to E Weight °T" Weight
C �J�°' �° Diameter Diameter Inches Each Inches Each Inches Each Inches Each
to E I -��`o Inches/mm Inches/mm mm Lbs./kg mm Lbs./kg mm Lbs./kg mm Lbs./kg
�
1'/4 1.660 - - - - - - 0.82 0.3
No.001 No.003 32 42.4 - - - - - - 21 0.1
� 1'/Z 1.900 2.75 1.2 1.75 0.9 2.75 2.0 O.S2 0.4
�-to E-� 40 48.3 70 0.5 45 4.1 70 0.9 21 0.2
0 Lc 0
2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 O.S8 0.6
�-�„f�o�, � C `-T 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3
to 2'/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0
°° E �I � 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5
1
No.002 No.006 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - -
76.1 76 1.5 57 1.1 - - - -
3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2
80 85.9 86 1.8 64 1.4 86 2.4 22 0.5
4.250 4.00 5.7 3.00 5.1 4.00 7.5 - -
108 mm �08.0 102 2.6 76 2.3 102 3.4 - -
4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4
100 114.3 102 3.0 76 2.5 102 3.9 25 1.1
5 5.563 4.88 12.6 325 8.3 4.88 15.7 1.00 4.1
125 141.3 124 5.7 S3 3.8 124 7.1 25 1.9
159 mm 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - -
155.8 140 5.7 89 4.2 140 8.0 - -
6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9
150 168.3 140 8.3 89 5.3 140 10.3 25 2.7
8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7
200 219.1 173 11.6 108 9.3 176 17.6 29 5.8
�REGISTERED TRADEMARK OF VICTAULIC-OO COPVRIGHT 2006 VICTAULIC-PRINTED IN U.S.A.-SKU#WCAS-67PJUX 7539 REV F
United States•Phone:1-800-PICK-VIC(1-800-742-5842)•Fax:610-250-8817•e-mall:pickvic@victaulic.com
Canada•Phone:905-884-7444•Fax:905-884-9774•e-mail:viccanatla@victaulic.com
Europe•Phone:32-9-381-1500•Fax:32 9-380-4438•e-mail:viceuro@victaulic.be
UK•Phone:44(0)1438741100•Fax:44(0)1438313883•e-mail:viceuro@victaulic.be ,����',���
Central and South America•Phone:610-559-3300•Fax:610-559-3608•e mail:vical@victaulic.com
Australasia•Phone:86-21-54253300•fax:86-21 54253671 •e-mail:vicap@victaulic.com
10.03
FLOW DATA
Frictional Resistance
Fitting Size Equivalent FeeUmeters of Straight Pipe
Actual Straight Tee
Nominal Outside No.002
Diameter Diameter 90°Elbow 45°Elbow
Inches/mm Inches/mm No.001 No.003 Branch Run
1�/4 1.660 1.5 0.8 3.7 1.5
32 42.4 0.5 02 1.1 0.5
1�/Z 1.900 22 1.1 5.5 22
40 48.3 0.7 0.3 1.7 0.7
2 2.375 3.5 1.8 8.5 3.5
50 60.3 1.1 0.5 2.6 1.1
2'/Z 2.875 4.3 2.2 10.8 4.3
65 73.0 1.3 0.7 3.3 1.3
76.1 mm 3.000 4.5 2.3 11.0 4.5
76.1 1.4 0.7 3.4 1.4
3 3.500 5.0 2.6 13.0 5.0
80 88.9 1.5 0.8 4.0 1.5
108 mm 4.250 6.4 3.2 15.3 6.4
108.0 2.0 0.9 4.7 2.0
4 4.500 6.8 3.4 16.0 6.8
100 114.3 2.1 1.0 4.9 2.1
5 5.563 8.5 4.2 21.0 8.5
125 141.3 2.6 1.3 6.4 2.6
159 mm 6250 9.4 4.9 25.0 9.6
158.8 2.9 1.5 7.6 2.9
6 6.625 10.0 5.0 25.0 10.0
150 168.3 3.0 1.5 7.6 3.0
8 8.625 13.0 5.0 33.0 13.0
200 219.1 4.0 1.5 10.1 4.0
t The flow data listed is based upon the pressure drop of Schedule 40 pipe.
MATERIAL SPECIFICATIONS
Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12
Fitting Coating: Orange enamel
• Optional: Hot dipped galvanized
This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.
Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations.
2 FireLock° Fittings
_.:•� . :. •� :•� � �
U� FM U�C ��� VdS ��PC�nd vds nuu�o��n,
see notes on page 4
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 005
WITH VIC-PLUST""GASKET SYSTEM (NORTH AMERICA ONLY)
FireLock°Style 005 rigid coupling has a unique, patented angle-pad design which allows the
housings to offset while clamping the grooves. By permitting the housings to slide on the angled
bolt pads, rigidity is obtained.
Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design
permits assembly by removing one nut/bolt and swinging the housing over the gasket.This PATENTED
reduces components to handle during assembly.
Style 005 FireLock coupling are designed and recommended for use ONLY on fire VIC ,'.`:
protection systems. casker sysrem
Vic-PIusT"" Gasket System:
In North America,Victaulic�offers a gasket system which requires no field lubrication on wet
pipe systems that are hydrostatically tested.The Vic-PIusTM System (patented) is tlry,clean,and
non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-
lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook(I-100)for
supplemental lubrication requirements and dry pipe fire protection system notes.
Exaggerated for clarity
LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of
publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.
Contact Victaulic for performance on other pipe and the latest listings and approvals.
5 1�/-3 175 US 175 EL 1%a-2 300 N/A N/A MT 1�/-2 300 N/A N/A
1'/a 4 350 3S0 3S0 CT 1%a Z 300 N/A N/A STF 1'/a 4 N/A N/A 300
10,40 5-8 300 300 300 EZ 4-6 300# N/A 300 S7hd Y 1'/a-7_ N/A N/A 300
BLT 1'/a-Z 300 300 N/A FF l Ya-4 N/A N/A 300 TF 3-8 N/A N/A 300
DF 1 Ya-4 300 300 300 GAL-7 1'/a-2 300 N/A N/A WLS 1'/a-2 300 300 N/A
DT 1'/a-Z 300 300 N/A MLT 1'/a-2 300 N/A N/A XL 1'/a-3 300 300 300
EF 1 Y 4 175@ N/A 175 MF 1 Ya-4 300 N/A 300'
*FM approved for service in 1 Y�-4"pipe.
#UL Listed for service up to 4"pipe only.
@ UL Llsted forservlce up to 3"only.
JOB/OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.a`�lJI1Cs
��'':��4- . . ... �...
�€`'� t.#`&��'J1P�0 `'°����. �"P�`Iv ' F'i�KL-. [i'd�c31'_.�TV�lf'�P G^i"e3._3C!I�Cuf iO�O�
���w�� -���-� ��r�r�� �I!'',�■r•.*��r�r�
STYLE 005
WITH VIC-PLUST'" GASKET SYSTEM (NORTH AMERICA ONLY)
DIMENSIONS
�
Y �Z�
� �
� X � � l Ya 1.660 350 755 0.05 2 75 450 1.88 L2
� _ � � 3Z 42A� Z413 3370 L2 2-3/a x 2'/n 70 114 148 OS
�� l Yz 1.900 350 990 0.05 3.00 4.75 1.88 LZ
40 483 2413 4415 L2 2-3/a x 2 Ya 76 121 148 OS
Rated for wet and dry sprinkler systems at 2 2375 350 1550 0.07 z_3/a x z Yz 3 50 5.25 1.88 1.6
350 psi/2413 kPa for 1'/a-4"/32-100 mm 50 603 2413 6900 1.7 89 133 148 OJ
sizes and 300 psi/2068 kPa for 4Y4-8"/108 Zyz z,g75 350 2Z70 0.07 4.00 5.75 1.88 1.9
-?OOmm sizes,Schedule 10 roll grooved or 65 73.0 2413 10110 1J z �e x z�Z 102 146 148 09
Schedule 40 cut ar roll grooved steel pipe. 3.000 350 2475 0.07 4.13 575 1.88 1.9
Style 005 is rigid and does not accommodate 76.1 mm 76.1 2413 11010 1J Z-'�a x 2 Yz �OS 146 148 0.9
expansion,contraction or angular deFlection.
3 3500 350 3365 0.07 4.63 6.13 1.88 2.1
80 889 2413 14985 1 J Z �8 X 2�Z 118 156 148 1.0
4 4.500 350 5565 0.16 z_,�e x z Yz 5.75 725 2.13 3.1
100 1143 2413 24770 4.1 146 184 54 1.4
108.0 mm 4.250 300 4255 0.16 �_,/a x z,� 5.63 Z25 2J3 3.1
108 0 2068 18940 4.1 143 184 54 1.4
5 5563 300 7290 OJ 6 Z_,�z X 3 6.88 9.00 2.13 45
125 1413 2068 3Z445 4.1 175 229 54 2.0
133.0 mm 5250 300 6495 0.16 z_YZ X Z,�4 6.63 9.00 2.13 45
133.0 2068 28900 4.1 168 229 54 2.0
5.500 300 7125 0.16 6.88 9.00 2.13 4.8
139J mm 139J 2068 31715 4.1 2-Yz x Z'/a 175 229 54 2.2
6 6.625 300 10340 OJ6 Z_,�zx3 8.00 10.00 2.13 5.0
150 1683 2068 46020 4.1 203 254 53 23
159.Omm 6.250 300 9200 OJ6 z_Yz X Z,�4 7.63 10.00 2.13 55
159.0 2068 40955 4.1 194 254 54 2.5
6.500 300 9955 0.16 8.15 10.00 2.13 55
165.1 mm �65.1 2068 44295 4.1 Z-��z X 3 207 254 54 ZS
8 8.625 300 17525 0.19 z_s��x 4'/a 1050 13.14 2.63 113
200 219.1 2068 78000 4.8 267 334 6/ 5.1
* Working Pressure and End Load are total,from all Internal and extemal loads,based on standard weight(ANSI)
steel pipe,standard roll ar cut grooved in accordance with Victaulic specifications.Con[act Vlctaulic for perfor-
mance on other pipe.
WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1 1/2 times
the figures shown.
t The allowable plpe separation dlmension shown is for system layout purposes only.Style 005 couplings are con
sldered rigid connections and will not accommodate expansion or contraction of the piping system.
@ Number of bolts required equals number of housing segments.Metric thread slze bolts are avallable(color coded
gold)for all coupling sizes upon request Contact Vlctaulic for details.
§ Style 005 couplings are VdS and LPC Approved to 12 Bad175 psl.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �CtaLJI1CJ
_.:•� .• :.. �
U� FM ��� vds LPCB
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLES 920 AND 920N
�
Victaulic Mechanical-T°Outlet provides a direct branch connection at any location a hole can -�- ,�
be cut in pipe.The hole is cut oversize to receive a "holefintler" locating collar which secures r
the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D.
Cross-type connections can be achieved by utilizing two upper housings of the same style and _ �
size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N
housings cannot be mated to each other to achieve a cross connection.
Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS
outlet. Specify choice on order. Units are supplied paintetl with plated bolts. Galvanized hous- ParENTeo
ings are available, supplied with plated bolts.
All sizes of Style 920 and 920N are rated at 500psi/3450kPa working pressure on Schedule
10 antl 40 carbon steel pipe.They may also be usetl on high density polyethylene or poly-
butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact
Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on
PVC plastic pipe.
Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be
installed so that the main and branch connections are a true 90°angle when permanently
attached to the pipeline surface.
Additionally,the Vic-Tap II°hole cutting tool,which allows for hole cutting capabilities on pressurized
systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to
create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information.
MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel
coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special
request.
• Optional: Hot dipped galvanized
Gasket: (Specify choice*)
• Grade"E" EPDM
EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C.
Recommended for cold and hot water service within the specified temperature range plus a
variety of dilute acids, oii-free air and many chemical services. UL Classified in accordance
with ANSI/NSF 61 for cold +86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR
PETROLEUM SERVICES.
• Grade"T" nitrile
Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C.
Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the
specified temperature range. Not recommended for hot water services over+150°F/+66°C or
for hot dry air over+140°F/+60°C.
�Services listed are General Service Recommendations only. It should be notetl that there are
services for which these gaskets are not recommended. Reference should always be made to
the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a
listing of services which are not recommended.
BoIts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical
requirements of ASTM A-449 and physical requirements of ASTM A-183.
JOB/OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA �Ct.aLII1C�
11.02
����.�.��:,,��� �n ������
STYLES 920 AND 920N
DIMENSIONS
�
< Y � �z� - -
� 2 Yz(a) 500 150 2.00 2.53 1.61 535 2.75 3.1
� 50 X 15 920N 3450 38.1 51 64 41 136 70 15
� r � 3�4�a� 920N 500 150 1.97 253 _ 1.61 535 275 3.1 _
20 3450 38.1 50 64 41 136 70 15
T 1 (a) 500 150 1.85 253 1.61 535 275 3.0
� 25 920N 3450 38.1 47 64 41 136 70 1.4
1 Ya(a)t 920N 500 1.75 205 275 3.00 1.61 535 3.00 3.5 32
GROOVED OUTLET 32 3450 445 52 70 76 41 136 76 1J 15
P/�(a)t 920N 500 iJ5 2.03 275 3.12 1.61 535 325 3.6 3.2
40 3450 44.5 52 70 79 41 136 83 1J 15
� Y -► < Z- > 2Y� Yz(a) 500 150 221 2J4 91.82 5.64 2.75 3.0
65 x 15 920N 3450 38.1 56 70 46 143 70 1.4
T 3/a(a) 500 150 218 2J4 1.82 5.64 275 3.0
V I � Z� 920N 3450 38.1 55 70 46 143 70 1.4
� � � 1 (a) gZ�N 500 150 206 274 _ 1.82 5.64 2.75 2.9 _
-- - ZS 3450 38.1 52 70 46 143 70 1.4
� 1 Ya t(a) 920N 500 175 Z30 3.00 3.25 1.82 6.29 3.00 3.5 3.2
32 3450 44.5 58 76 83 46 160 76 1J LS
FEMALE THREADED OUTLET P/z t(a) 920N 500 2.00 2.28 3.00 325 1.82 6.26 3.25 3.6 33
40 3450 50.8 58 76 83 46 159 83 1J 1.6
Yz(a) 300 1.50 2.22 2J5 2.25 6.46 3.18 3.9
76.1 x 15 920 2065 38.1 56 70 57 164 Sl 1.8
• Provides a direct branch connection at 3r4�aJ 920 300 �so z�9 z.�s zzs 6.46 3.�a 3.9 _
any location where a hole can be cut zo zo6s 3a.� s6 �o - s� �64 s� i.a
in the pipe � (a) 920 300 �so zm z.�s zzs 6.46 3.�s 3.s _
ZS 2065 38.1 53 70 57 164 81 1J
• A pressure responsive gasket provides ��r�caJ 920 soo i.�s z.3o 3.00 3.3> >.9z b.z9 3.00 3s 3.z
the seal 32 3450 44.5 58 76 84 49 160 76 1.6 15
1 Yz(a) 920 500 2.00 2.�8 3.00 331 19Z 629 3.25 3.5 33
• Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 15
Mechanical-T cross assemblies 3 vz(aJ soo �so zsz 3.os z.za 6.�s z.�s 3.4
80 x 15 920N 3450 38.1 64 78 58 156 70 1.6
• Pressure rated up to 500psi/3450kPa 3r4(a) 9zoN soo �so z.49 3.os z.za 6�s z.�s 3.4 _
on steel pipe; also available for use zo 34so 3a.� 63 �a - sa �s6 �o �.6
with HDPE pipe � �a� 9zoN soo �so z.3s 3.06 z.�a 6.�s z.�s 3.3
?_5 3450 38.1 61 78 58 156 70 1.6
• Sizes from 2 x 1/z���5� X 15 mm 1 Ya(a)t) 920N 500 1J5 2.55 3.Z5 3.56 Z.28 6.15 3.00 3 8 3J
through 8 x 4���2��X 100 mm 32(b 3450 445 65 83 90 58 156 76 1.8 1.8
1 Yz(a)t 9ZON 500 2.00 278 3.50 3.56 �.28 6.15 3.Z5 4.1 3.8
40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8
z�a� 920N 500 Z.50 ZJS 3.50 3.56 2.Z8 6J5 3.88 4.9 4.6
50 3450 63.5 70 89 90 58 172 99 23 2.1
3'/z 2 500 �.50 3J5 2.44 672 3.88 3.8
90 X 50 9ZON 3450 635 95 62 171 99 1.8
IMPORTANT NOTES: TABLE CONTINUED ON PG.3
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.�I.lI1C3
11 .02
IA�I,�,,�L����,�a,l Tn [�,�,���,P! �
STYLES 920 AND 920N
DIMENSIONS
�
E v � �z�
� TABLE CONTINUED FROM PAGE 2
V a x ���a� 920N 500 L50 3 03 356 2.69 7.01 2J5 3J
� � � 100 15 3450 38.1 77 90 68 178 70 1.8
����� 920N 500 t50 3.00 3.56 269 7.01 2J5 3J
!� 20 3450 38.1 76 90 68 178 70 1.8
� 1 (a) gZ�N 500 L50 2.88 3.56 _ 2.69 7.01 2J5 3.6
25 3450 38.1 73 90 68 178 70 1.8
GROOVED OUTLET 1'/4(a)t 920N 500 1 JS 3.08 3J8 4.00 269 7.01 3.00 4.0 3.6
32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8
1 Yz(a)t 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 325 4Z 3.9
E Y..- � <,--Z_� 40(b) 3450 50.8 83 102 10Z 68 178 83 Z.0 1.9
2(a)t 920N 500 250 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6
50 3450 63.5 83 102 102 68 178 99 Z3 2.1
� � � 2 Yz(a)t 920 500 2J5 2.88 4.00 4.00 269 734 4.63 5.8 5.0
65 3450 69.9 73 102 102 68 1S6 118 2.6 23
� 76.1 mm 920 500 2J5 4.00 2.69 734 4.63 6.4
� W 3450 69.9 102 68 1S6 118 2.9
� 3(a)t 920 500 3.50 331 4.50 4.12 2.69 7J3 5.12 8.4 6.4
80 3450 88.9 84 114 105 68 196 130 3.8 2.9
FEMALE THREADED OUTLET
1 Ya(a) 500 1 JS 3.08 3J8 263 7.64 3.05 5.0
108.0 x 32 920N 3450 44.5 78 96 67 194 78 23
������ 920N 500 2.00 3.25 4.00 2.63 7.64 325 5.0
• Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 Z3
any location where a hole can be cut z(a) 9zoN soo zso 3.zs 4.00 z.63 z64 a.00 a.o
in the pipe so 34so 63s a3 ioz - 6� i94 ioz i.9
76.1 mm yZp 500 2J5 2.88 4.00 4.00 263 7.64 429 8.0
• A pressure responsive gasket provides 3aso 69.g �3 ioz ioz 6� �9a io9 3.6
the seal 3(a) 920 500 3.50 331 4.50 2.63 7.63 4.88 6.8 6.5
80 3450 58.9 84 114 67 194 124 3.1 3.0
• Request Publication 11.03 for 5 1 Yz(a)t 500 2.00 4.03 4J5 4J5 3.16 9J0 3.69 7.4 7.6
Mechanical-T cross assemblies �zs X 40 920 34so so.a �oz iz> >zi so z46 9a 3.a 3.4
2(a)t 500 2.50 R.00 4J5 4J5 3.16 9J0 438 8.2 8.0
• Pressure rated up to 500psi/3450kPa so 9zo 3aso 63s �oz �z> >zi eo z46 in 3.� 3.6
on steel pipe; also available for use riz(a)t 920 soo z.�s 3.63 4.�s 4.�s 3.�6 9.�0 4.63 a.3 z9
with HDPE pipe 65 3450 69.9 92 121 1Z1 80 246 118 3.8 3.6
76.1 mm 920 500 2J5 4J5 3.16 9J0 4.63 8.0
• Sizes from 2 x 1/z"/50 x 15 mm 3aso 69.9 - - �zi so z46 >>s - 3.6
through 8 x 4"/200 x 100mm 3(a)t 920 soo 3so 3.s� s.00 a.63 3.i6 9.�o s.3� a.a s.e
80 3450 58.9 97 127 118 SO 246 135 3.8 4.0
2 500 2.50 3J5 4.50 3.0 8.00 3.88 8.0
133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6
3 500 3.50 3.81 5.00 3.00 9.46 531 8.0
80 y20 3450 88.9 97 127 76 240 135 3.6
TABLE CONTINUED ON PG.4
IMPORTANT NOTES:
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.`caUI1C�
.. ..l.��i �
11.02
����.�.��:,,��� �n ������
STYLES 920 AND 920N
DIMENSIONS
�
E v � �z->
� TABLE CONTINUED FROM PAGE 3
V 139J x ���t 920N 500 2.00 3J8 450 330 8.23 3.25 7.0
� � � 40 3450 50.8 96 114 84 209 83 3.2
_ _ 2 t 920N 500 2.50 3J5 4.50 330 8.23 3.88 9.0 _
T - 50 3450 63.5 95 114 84 209 99 4.1
W 500 2J5 3.63 4J5 3.13 9.85 4.63 8.8
y 76.1 mm 920 3450 69.9 92 1Z1 80 250 118 4.0
GROOVED OUTLET 76.1 mm 92p 500 3.50 _ _ 4.63 3.16 9J0 531 11.0 _
3450 88.9 118 80 246 135 5.0
3 500 3.50 3.81 5.00 4.63 3.16 9.85 538 14.0 14.2
� Y � < Z .> gg 9 920 3450 88.9 96.80 127 118 80 250 137 6.4 6.4
6 1 Ya(a) 500 1J5 4.43 3J9 9.15 3.25 4.8
150 x 3Z(b) 920N 3450 44.5 112 96 232 83 2.2
V
� 1 Yz(a)t 500 2.00 4.40 5.13 5.13 3J9 9.15 3.25 5.4 5.1
� � �� 40(b) 920N 3450 50.8 112 130 130 96 232 83 2.4 23
� 2(a)t 920N 500 2.50 438 5.13 5.13 3J9 9.15 3.88 6.0 5.6
W 50 3450 63.5 111 130 130 96 232 99 2J Z.5
� ZYz(a)t 920 500 2J5 4.01 5.13 5.12 3.69 1Q51 4.63 S3 7.6
65 3450 69.9 110 130 130 94 267 118 3.8 3.4
FEMALE THREADED OUTLET
76.1 mm 9zp 500 2J5 _ 5.�1 3.69 iQ51 4.63 _ 8.4
3450 69.9 132 94 267 118 3.8
3(a)t 500 3.50 431 5.50 5.13 3.69 1Q51 531 9.9 8.4
• Provides a direct branch connection at 80 y20 3450 88.9 110 140 130 94 267 135 4.5 3.8
any location where a hole can be cut 4(a)t 920 500 4.50 3.81 5J5 538 3.69 1Q51 6.25 10.1 10.1
in the pipe ioo 34so >>4.3 9� i46 �3� 94 zb� is9 4.6 4.6
l Ya 500 1 J5 4.43 5.13 3.63 9.40 3.25 9.0 8J
• A pressure responsive gasket provides 159.0 x 32 920N 3450 44.5 113 130 92 239 83 4.1 4.0
the seal �����a� 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8
40 3450 50.8 112 130 92 239 83 3.5
• Request Publication 11.03 for ��a� 920N 500 2.50 438 5.13 3.63 9.40 3.88 8.0 _
Mechanical-T cross assemblies so 34so 63s i>> >30 - gz z39 99 3.6
76.1 mm 920 500 2J5 438 5.50 5.13 3.63 9.40 4.63 9.5 9.5
• Pressure rated up to 500 psi/3450 kPa 3450 69.9 111 140 130 92 239 118 43 43
on steel pipe; also available for use 3 920 500 3.50 431 5.50 5.13 3.63 9.40 531 8.1 14.0
with HDPE pipe 80 3450 88.9 110 140 130 92 239 135 3J 6.4
108.1 mm 920 500 4.50 538 3.63 9.40 6.12 10.0
• Sizes from 2 x lh"/50 x 15mm 34so u4.3 - - �3� 9z z39 iss - 4s
through 8 x 4'Y200 x 100mm 4 9zo soo aso 3.81 s.�s 3.63 9.ao 6.zs �s.o
100 3450 ll43 96.80 146 92 239 159 82
TABLE CONTINUED ON PG.5
IMPORTANT NOTES:
Style 920 and Style 920N housings cannot be
mated to one another
to achieve cross connections.
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.�I.lI1C3
_::•� :.� � . • � � • � :
U� FM U�C Vds
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 750
� S � �y
The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed
to replace two couplings and a reducing fitting,the Style 750 features a special reducing t ��� �
gasket for pressure responsive sealing. A steel washer which prevents telescoping of the �
smaller pipe inside the larger pipe during vertical systems assembly is available upon —�
request. ,r�
�- --I
i �J�L�JI,.II
Exaggerated for clarity
MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65 45-12 Ductile iron conforming to ASTM
A-395, grade 65-45-15, is available upon special request.
Housing Coating: Orange enamel
• Optional: Hot dipped galvanized and others
Gasket: (Specify choice*):
• Grade"E" EPDM (All other sizes)
EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C.
Recommended for cold and hot water service within the specified temperature range plus a
variety of dilute acids, oiI free air and many chemical services. UL classified in accordance
with ANSI/NSF 61 for cold +86°F/+30°C and hot+180°F/+82°C potable water service. NOT
RECOMMENDED FOR PETROLEUM SERVICES.
• Grade"T" nitrile
Nitrile(Orange color code). Temperature range—20°F to+180°F/-29°C to+82°C.
Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the
specified temperature range. Not recommended for hot water services over+150°F/+66°C or
for hot dry air over+140°F/+60°C.
` Services listed are General Service Recommendations only. It should be noted that there are
services for which these gaskets are not recommended. Reference should always be made to
the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a
listing of services which are not recommended.
• Optional: Assembly Washer: Galvanized, carbon steel
Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical
requirements of ASTM A-449 and physical requirements of ASTM A-183.
JOB OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para
Location Date Approved
Date
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Ct.a`�lJI1C�
06.08
. �• �� FP4 U�C VdS
�,r�„�r�,�n��ro�tr �'�� R�, R�.+r
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 750
r'�� -."°<;
�� �
'.t� � �
_�
DIMENSIONS
� �
2 1 350 1000 0-0.07 0.70 33S SJ8 1.88 7J
50 X 25 2410 4450 0-1.8 ��-57 17 �-��a X� 85 134 48 1.2
1'/� 350 1000 0-Q07 0.20 338 5.28 1.88 2.0
40 2410 4450 0-1.8 � -57 17 �-��a X� 85 134 48 1.0
2 Yz ?. 500 2215 0-0.07 0.16 4.00 5.93 1.88 3.1
65 X 50 3450 9850 0-1.8 � -47 14 Z-3�a X Z 102 1 S 1 48 1.4
76.1 mm x 2 350 1550 0-0.07 0.16 438 6.63 1.88 4.6
SO 2410 6900 0-1.8 � -47 14 z-��z X Z 3�° 11 1 168 48 2.1
3 2 350 1550 0-0.07 0.13 4J5 7.13 1.88 4.9
80 X 50 2410 6900 0-1.8 � -39 11 �-���X�3�4 121 181 48 2.2
2%z 500 3J_50 0-0.07 0.13 4J5 7.13 1.88 43
65 3450 14460 0-1.8 � -39 ll �-���X���4 121 181 48 2.0
350 2275 0-0.07 0.13 4J5 7.13 1.88 4.2
88.9mm x 76.1mm 2410 101Z5 0-1.8 � 39 11 �-��X�3�4 121 181 48 1.9
4 2 350 1550 0-0.13 0.28 6.25 8.90 2.25 8.1
100 X 50 2410 6900 0-3.2 � -�9' 25 2-s/a x 3'/a �59 226 57 3.7
2Yz 350 7J_75 0-0.13 0.28 6.?_5 8.90 7.7_5 8.6
65 2410 10125 0-32 � -�9' ZS 2-s/a x 3'/c �59 226 57 3.9
3 500 4810 0-0.13 Qz8 6.00 8.90 2.Z5 6J
80 3450 21400 0-32 1°-19' 25 2-s/ax3'/a 152 226 57 3.0
350 Z275 0-0.13 Q28 625 8.90 225 6.9
1143mm x 76.1mm 2410 10125 0-3.2 � -19' 25 Z-s/ax3'/4 159 226 57 3.1
5 4 350 5565 0-0.13 0.22 7.18 10J0 2.13 1 1 Z
125 X 100 2410 24765 0-3.2 � -3' �9 2-'/a x 4Ya �82 Z�Z 54 SJ
6 4 350 5565 0-0.13 0.18 8.63 1 1.90 2.25 16J
150 X 100 2410 24765 0-3.2 0°-52' 15 2-'/a x 4Ya 181 302 57 7.6
5 350 8500 0-0.13 0.18 831 ll.90 2.25 1 Z.9
125 2410 37825 0-3.2 � -5� 15 �-3�ax4Ya 211 302 57 5.9
165.1 mm x 4 350 5565 0-0.13 0.19 8.63 1 1.90 2.25 15.2
100 2410 24765 0-3.2 0°-55' 16 2-'/a x 4Ya 219 302 57 6.9
8 X 6 350 12000 0-0.13 ��_38� 0.13 Z_,�g X 5 10.81 14.88 250 z2.4
200 150 2410 53400 0-3.2 11 275 378 64 10.2
Refer to notes on back cover.
Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details.
.f y� �F��� Y� �FZ�
� �
� X � � X
�
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �CtaLJI1CJ
06.08
' UO FM U�C VdS
�m?�,!^�m m a^�r►r� �'A^�,,��'��i n �
� SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 750
x
_ �
:��
-- � .
i }
� , � � __
` . ....
FLOW DATA HEAD LOSS
The head loss across Style 750 Reducing coupling is very small and is essentially the same as for
standard short body reducing pipe fittings.
Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water
flowing at ambient temperature.
FLOW REDUCING FLOW EXPANDING
z i s.9 z z�
50 X ZS 1.8 ZS X 50 0.8
1'/z 2.0 1 Yz 2 1.9
40 0.6 40 X 50 0.6
Z Yz Z 19 Z 2 Yz 1.0
65 X 50 0.6 50 X 65 0.3
76.1 mm x 50 0.6 76.1 mm �0
3 2 5.5 3 3.5
80 X 50 1 J 80 1.1
2'/z 3.8 4 3.0
65 L2 100 0.9
,
88.9mm x 76.1 mm L2 65 X 80 0.8
4 Z 6.0 4 3.0
100 X 50 1.8 100 0.9
,
65� 1.8 76.1 mm x 88.9mm 08
g� 68 1143mm �9
U43mm x 76.1mm 68 g0 X 100 0.8
5 4 3.0 4 5 33
125 X 100 0.9 100 X 125 1.0
6 4 6.0 6 4.6
150 X 100 1.8 150 1.4
5 4.5 165.1 mm 4.6
1Z5 1.A 1.4
4 6.0 5 6 23
165.1 mm x 100 1.8 125 X 150 OJ
S 6 73 6 8 6.0
Z00 X 150 2.Z 150 X 200 1.8
www.victaulic.com
VICiAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �CtaUI1Cc
..._. ..�� J
.
_,:.� :.• . • � � � � •
U� FM U�C Vds
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
STYLE 750
� ,�
� �..
o� �-�
-<� � �
-- '�
GENERAL NOTES � Working Pressure and End Load are total,from all internal antl external loads, based on
standard weight(ANSI)steel pipe, standard roll or cut grooved in accordance with Victaulic
specifications. Contact Victaulic for performance on other pipe. Maximum working pressure
rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.
WARNING: FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be
increased to 11/z times the figures shown.
t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of
movement available at each joint for standard rall grooved pipe. Figures for standard cut
grooved pipe may be doubled.These figures are maximums;for design and installation
purposes these figures should be reduced by: 50%for 3/a-3'/z"/20-90 mm; 25%for
4"/100mm and larger.
@ Number of bolts required equals number of housing segments.
Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.
Contact Victaulic for details.
WARNING: Depressurize and drain the piping system before attempting to install, remove,or adjust
any Victaulic piping products.
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the
right to change product specifications,designs and standard equipment without notice and without
incurring obligations.
P.O. Box 31 905-884-7444 1-610-559-3300
Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax)
4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com
Easton, PA 18040 USA _ _., .._
1-800-PICK-VIC(1-800-742-5842) 32-9,381-15-00 86-21-54253300
1 610 559 3300 32-9-380-4438(fax) 86-21 54253671 (fax)
1-610-250-8817(fax) viceuro@victaulic.be vicap@victaulic.com
pickvic@victaulic.com
www.victaulic.com III II II I III I III IIIIIIII III I II II IIIIII III III
44(0) 1438741100 971-4-883-88-70
44(0) 1438313883(fax) 971-4-883-88-60(fax) WCAS-6QAQRU
viceuro@victaulic.be
UPDATED 6/2006
06.08 1536 REV H IC.t'ca�,1�1�+�
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY.OO 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA.
� . o /��i`�StarTM
Welded Outlet Fittin�5 Fire Products Division ofAnvil`Intemational
For Fire Protection & Submittal Sheet
MERIT� Other Low Pressure Piping Systems
Merit Weld-MiserT"' Tee-Let° Welding Branch Outlet Fittings offer the
user a high strength, low cost forged threaded and grooved line of
fittings specifically designed and manufactured to be installed on
Schedules 5 thru 10, proprietary thin wall flow pipe and standard
�� ,
wall pipe. . -=
Merit Tee-Lets are forged steel welding outlet fittings. The material �{
used in manufacture meets the chemical and physical requirements of �;
ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ ,� �
a low weld volume design to provide for either a partial or full � ��
penetration weld employing a single pass with minimum burn-through
and pipe distortion. Weld Miser Tee-Lets are recommended for use on
proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply �'^��...�
with ANSI B1 .20.1 or IS07/1. They are UL Listed and FM Approved
for use conforming to the requirements of Bulletin 13 1999 of the
National Fire Protection Association. When used in fire sprinkler
systems, Tee-Lets are rated for 300 psi. When used in mechanical
systems, maximum pressures are calculated using criteria developed U� U�C
for ASME B31 piping code.
FM
APPROVED
For Listing/Approval
details contact your
AnvilStarT"^Representative.
� � �
I � � � � � - _ � - � - �
Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure
In. In. psig
'/�,3/a,1 Yz-8(S�h.10,40)
Tee-let Type A 1�/a,1�h,2,2�/Z,3,4 �/z-4(Sch.5,DynaFlow)
300
(F-Threaded End) p 4(EZ-Flow)
2,4 6(EZ-Flow)
Tee-Let Type C 1�/a-8 1 Yn-8(Sch.l 0,40)
(Grooved End) 300
2Ys-8 �h-4(Sch.5,DynaFlow)
Tee-Let Type C/R 1�la-b 1�/a-8(All Schedules) 300
(Roll Grooved End)
. � � . � � . . �
Project:
Date: Phane:
Architect/Engineer:
Contractor:
Address:
Notes 1:
Notes 2:
PAGE 1 OF 5
Merit°Tee-Lets & Drop Nipples For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, �,; -�NV'L
(��Z�i
REV.03.03.06-001 go to www.anvilslar.com or contact your local AnvilStar representative �
� . o /��i`�StarTM
Welded Outlet Fittin�5 Fire Products Division ofAnvil`Intemational
Submittal Sheet
MERIT�
UNIFIED DESIGNT"^ SERIES '
Merit's Unified Design Series carries all important � • Threads are cut in accordance with the requirements
design considerations into its entire line of welding I of ANSI Bl .20.1, national standard for tapered pipe
branch outlet fittings. � threads, or ISO-7-1 threads are available.
Merit� Weld-MiserT"' Tee-Lets� are designed - --I • Tee-Let threaded and grooved welding outlet fittings
and Manufactured to reduce the amount of weld � are UL/ULC Listed and FM Approved for use in the
required to install the Tee-Lets on thin wall or fire sprinkler systems installed in accordance with the
proprietary flow pipe. Typically only one weld-pass � requirements of NFPA Bulletin 13. They are rated for
completes the installation. Merit Tee-Lets install with less 300 PSI operation in fire sprinkler systems, and higher
weld volume than any other brand of welding outlet pressures in other non-critical piping systems.
fittings for fire sprinkler applications. To accomplish this:
• Tee-Lets are offered in a wide variery of header sizes.
• The contoured end of the fittings employs a reduced The consolidated header sizes shown in the following
outside diameter. Two major advantages are charts allow the fittings to be installed on more than
immediately apparent: one header size, permitting the first size listed to fit
• The thinner wall on the contoured end permits welding the header perfectly, while a small gap along the
temperatures to be matched to the thickness of longitudinal center line of the header will appear for
the branch line or main thereby insuring complete the second size listed.
penetration without cold welds, weld roll-off, burn- • Merit° Weld-MiserT"' Tee-Lets° are identified by a lot
through or excessive distortion. number that provides full traceability per ISO 9000
• On smaller sizes a heavier section is maintained specifications.
on the threaded end of the fitting. This protects the
threads from damage during shipping and handling
prior to installation as well as from weld distortion. FOR YOUR PIPING SYSTEMS SPECIFY
WELD-MISERT'" TEE-LET�
• Each outlet size 1 �h" and larger, whether male or Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let,
female threaded, cut grooved or beveled requires the Lightweight forged steel, employing low weld volume
same hole size in the header pipe. This simplifies the profile to provide for full penetration welds with minimum
installation process. burn through and pipe distortion on Schedule 5 thru 10,
proprietary thin wall, and standard wall pipe. Threads
are to be ANSI B 1 .20.1, or ISO-7-1, and the bore of
GENERAL SPECIFICATIONS the fittings calculated to improve flow. Welding outlets to
• Tee-Let welding outlet fittings are manufactured from be UL Listed, FM Approved for use conforming to NFPA,
highly weldable steel which conforms to the chemical Bulletin 13 and pressure rated for 300 PSI maximum.
and physical requirements of ASTM A-53, Grades
A or B, Type E. Ease of installation is assured when
automatic welding equipment is used to install Merit
Tee-Lets.
PAGE20F5
Merit°Tee-Lets & Drop Nipples For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, ;'
Rev.os.os.o�oo2 go to www.anvilslar.com or contact your local AnvilStar representative �!Z�� ��V�L
� . o /��i`�StarTM
Welded Outlet Fittin�5 Fire Products Division ofAnvil`Intemational
�
Submittal Sheet
MERIT� A I
Type A � � �
Female Thread � i C
M ---- �
I�p�I
------�----e �--
�
� �
. � . . . � . .
� �
Nominal Nominal Outlet Inside Nominal Nominal Outlet Inside
Outlet Header Length Diameter Make Up Pnrt OuTlet Header Length Diameter Make Up
Part Number A B ( D M Weight Each Number A B ( D M Weight Each
NPT(BSPT) In(mm) In(mm) In(mm) In(mm) In(mm) Lb.(kg) NPT IBSPT) In(mm) In(mm) In(mm) In(mm) In(mm) lb.(kg)
1002002 /a x 1/a-8 0.080 1020020 2 1.750 2.061 0.875 0.857
- 6 a 6 200 0.04 1120020 50 445 525 222 0.38
1005012 l�la-l�h 1.063 OJ00 0.500 0.171 1020025 2�/z 1J50 2.061 0.875 0.829
32 40 27.0 17 8 12J 0.08 112002� 65 44.5 525 22.2 0.38
1005015 1Y2-2 1.063 0.700 0.500 0.171 �020030 3 1.750 2.067 0.875 0.829
- h x 40 50 27.0 11.8 12J 0.08
1005020 13« 2-2Y2 1.063 OJ00 0.500 0.171 1120030 80 445 525 222 0.39
- 50 65 27.0 17.8 12 7 0.08 1020040 2 z 4 1J50 2.067 0.875 0.800
1005025 2'/z-8 1.063 OJ00 0.500 OJ69 ll20040 50X 100 n4S 525 22.2 0.36
- 65 200 27.0 17.8 12J 0.03 1020050 5 1J50 2.061 0.875 OJ43
1007012 1/a-1/z 1.125 0.900 0.500 0.260 ll 20050 125 44 5 525 222 0 34
32 n0 28 6 22.9 12 7 ���2 1020060 6 1.750 2.067 0.875 0.743
1001015 1/z-2 1.125 0.900 0.500 0.260
- 3/a x 40 50 28.6 22.9 127 p.12 11200G0 150 44.5 525 222 0.34
1001020 19« 2-2�/z 1.l 25 0.900 0.500 0.260 1020080 8 1 J50 2.061 0.875 OJ43
- 50 65 28.G 22.° 12J 0.12 112003G 200 44 5 525 222 0.34
1001025 2Yz-8 1.125 0.900 0.500 0.256 1025025 2�/z 2.215 2.469 1.125 1.250
- 65 200 2�.6 229 12J 0.12 ll2502� 65 54.0 G2J 28.G 0.55
1010012 1/a-1 h 1.250 1.145 0.500 0.331 1025030 3 2.215 2.469 1.125 1.200
1110012 32 40 31.8 2°.l 12J 0.15 1125030 80 54.0 62J 28 6 055
1010015 lYz-2 1.250 1.145 0.500 0.331 1025040 4 2215 2.469 1.125 1.150
1110015 40 50 31.8 29.1 12J 0.15
1010020 2-2�/z 1.250 1.145 0.500 0.320 1125040 2�/z x 100 54.0 62_7 28_6 052
1 I 10020 1 x 50 65 31 8 29.1 12.7 0.15 1025050 65" 5 2.215 2.469 l.l 25 1.150
1010025 25 x 2�/z-3 1.250 1.145 0.500 0.314 1125050 125 54 0 62.7 28 6 0.52
1110025 65-80 31.8 29.1 12.� 0.14 1025060 6 2.215 2.469 1.125 1.150
1010030 3-4 1.250 1.145 0.500 0.309 1125060 150 54.0 G27 28.6 052
i 110030 80 100 31 S 29.1 12 I 014 1025080 8 221 S 2.469 l.l 25 1.150
1010050 5-8 1.250 1.145 0.500 0.291 1125080 200 54 0 62J 28G 0.52
1110050 125 200 31.8 29.1 12J 0.13 1030030 3 2.500 3.068 1.500 1.750
1012012 1/a-1 h 1.375 1.490 0.500 0.432 - 80 G3 5 77.9 38.1 OJ9
1112012 32 40 34 9 37.8 12.7 Ol9 1030040 4 2.500 3.068 1.500 1.700
1012015 1'/2-2 1.375 1.490 0.500 0.421 _ 100 635 779 381 OJ7
1112015 40 50 34.9 37.8 12.7 019 1030050 3 x 5 2500 3.068 1.500 1 J00
1012020 2-2Yz 1.375 1.490 0.500 0.421 g�� 125 G3 5 77 9 381 0 77
1112020 1�/qx 50 65 34.9 37.8 12J Ol9
1012025 32 x 2Yz-3 1.375 1.490 0.500 0.411 1030060 6 2.500 3.068 1.500 1.650
1I12025 65 80 34.9 37.8 12J 019 - 150 63.5 77.9 38.1 0]5
1012030 3-4 1.375 1.490 0.500 0.389 1030080 8 2.500 3.068 1.500 1.650
1112030 80 100 34.9 37 8 127 018 - 200 63.5 7%.9 38.1 OJ5
1012050 5-8 1.375 1.490 0.500 0.389 1040040 4 3.000 4.026 2.000 3.000
1112050 125-200 34.9 31.8 12J O18 - 100 762 102 3 50 S 1.36
1015015 1/z 1.625 1.610 0.815 0.471 1040050 5 3.000 4.026 2.000 2.900
1115015 40 �Il.3 409 22.2 022 - 4 x 125 76.2 102.3 50.8 1.32
1015020 2 1.625 1.610 0.875 0.477 1040060 100� 6 3.000 4.026 2.000 2.800
1115020 50 41.3 409 222 022 �50 762 102.3 50.8 L27
1015025 2�/z 1.625 1.610 0.875 0.411
1115025 1'h x 65 41.3 q0.9 222 �p2 1040080 8 3.000 4.026 2.000 2.800
1015030 40 x 3-4 1.625 1.610 0.875 0.471 - 200 76 2 102.3 50 8 1.27
1115030 80 100 41.3 40.9 22.2 �22 NOTE:Part#1002002 is not UL Listed or FM Approved.
1015040 4 1.625 1.610 0.875 0.477 All size-on-size(i.e.2 x 2)Tee-Lets are not FM Approved.
i 115040 100 41.3 409 222 022
1015050 5-8 1.625 1.610 0.815 0.471
1115050 125 200 41.3 409 222 022
PAGE30F5
Merit°Tee-Lets & Drop Nipples For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, ;'
Rev.os.os.o�oos go to www.anvilslar.com or contact your local AnvilStar representative �!Z�� ��V�L
� . o /��i`�StarTM
Welded Outlet Fittin�5 Fire Products Division ofAnvil`Intemational
Submittal Sheet
MERIT� Type B Type C
Male Thread Cut Groove
Standard Weight Standard Weight
�E E -� A �E E � A
� �
C �
� � <- F � � FF
B� I� D �I B� I�D�I
. � . . . �
cur ourler
Male Thread 6roove Nominal Outlei Nominal Header Lengfh Inside Diameter Outside Diameter Wall Thickness
Std.Wt. Std.Wt. A B C D E F
NPT(BSPT) NPT(BSPT) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm)
1310012 2010012 1�/a-1 Ys 3 1.049 1.315 0.133
32 1.0 c0 c
1310015 2010015 lYs-2 3 1.049 1.315 0.133
40 50 30 26.6 33.4 3.4
1310020 2010020 1 x 2-2�/z 3 1.049 1.315 0.133
25 x 50 65 80 26.6 33.4 3.4
1310025 2010025 2�h-4 3 1.049 1.315 0.133
65 100 80 26.6 33.� 3.4
1310050 2010050 5-8 3 1.049 1.315 0.133
125�200 80 26.6 33.4 3.4
1312012 2012012 lYu 3 1.368 1.660 0.140
32 80 3<lJ 422 3.6
1312015 2012015 lYz 3 1.368 1.660 0.140
90 80 34J 422 3.6
1312020 2012020 1�/a x 2-2Yz 3 1.368 1.660 0.140
32 r SO�65 8G 34J 422 3.6
1312025 2012025 3-4 3 1.368 1.660 0.140
80 100 80 34J �22 3 6
1312050 2012050 5-8 3 1.368 1.660 0.140
125 200 80 34.7 �22 3.6
1315015 2015015 lY2 3 1.610 1.900 0.145
40 80 40.9 48.3 3.7
1315020 2015020 2 3 1.610 1.900 0.145
50 80 40.9 43.3 3J
1315025 2015025 lYzx 2Yz 3 1.610 1.900 0.145
40 X 65 80 40.9 4�.3 3J
1315030 2015030 3-4 3 1.610 1.900 0.145
80 100 80 40.9 48-3 3.1
1315050 2015050 5-8 3 1.610 1.900 0.145
125 200 80 409 48 3 3J
1320020 2020020 2 3 2.067 2.375 0.154
50 80 52.5 60_3 3_4
1320025 2020025 2'/z 3 2.067 2.375 0.154
65 80 52.5 G0 3 3.4
1320030 2020030 3 3 2.067 2.375 0.154
80 80 525 G0.3 3.9
1320035 2020035 2z 4 3 2.067 2.375 0.154
50 a 100 80 525 G0.3 39
1320050 2020050 5 3 2.067 2.375 0.154
125 EO 52.5 G0.3 3.9
1320060 2020060 6 3 2.067 2.375 0.154
150 SO 525 60.3 3.9
1320080 2020080 8 3 2.067 2.315 0.154
?00 80 >2.5 6Qi 3?
NOTE:Tee-Lets are manufactured to fit size-on-size,that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size
marked on the fiHing,a slight gap of approximately�/3z"will appear along the longitudinal centerline of the header. For example,a 1"x 2-2�/z"Tee-Let,is a 1"outlet fiHing manufactured to
fit perfectly on the 2"header size listed,while leaving a�/32"gap along the longitudinal centerline of the 2Y2"size.If a perfect fit is required for a 2�h"header pipe,then a 1"x 2�h-3"Tee-Let
would be ordered.Size consolidations are employed to reduce inventory and provide for greater flexibility. PAGE 4 OF 5
Merit°Tee-Lets & Drop Nipples For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, ;'
Rev.os.os.o�ooa go to www.anvilslar.com or contact your local AnvilStar representative �!Z�� ��V�L
� . o /��i`�StarTM
Welded Outlet Fittin�5 Fire Products Division ofAnvil`Intemational
Submittal Sheet
MERIT� Type B Type C Type C/R
MaleThread Cut Groove Roll Groove
Standard Weight Standard Weight Schedule 10
IE E � A IE E - q �E E -I A
� '�, � �, � �,
C I � I C I
� -> FF � ', � FF � ', F
I� D � B� I�D�I B (<-D�I
B� � �
� � ■ � � �
Inside Diameter - D Wall Thickness - F
Male Nominal Nominal
Thread (ut Roll Groove Outlet Header Outlet Lengih Schedule Outside Diameter Schedule
Std.Wt. Groove Std.Wt. Sch.10 A B ( Standard Weight 10 E Standard Weight 10
NPT(ISO-1-1) NPT(ISO-7-1) NPT(ISO-7-1) In.�mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm)
1325025 2025025 2225025 2�h 3 2.469 2.635 2.875 0.203 0.120
> �ii 65 80 c[J i;1-!i i(ii `;i; r
1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120
2125030 80 80 62J 67 0 76.2 5.0 3_0
1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120
212�03i p�/p X 100 80 62J 67 0 762 5-0 3 0
1325050 2025050 2225050 bsY 5 3 2.469 2635 2.875 0203 0.120
2125050 125 80 62J b7_0 76.2 5.0 3-0
1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120
2125060 175 80 62.7 67 0 762 5.0 3 0
1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120
2125080 200 80 62J 67 0 76.2 5.0 3 0
1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120
80 80 78.0 83 0 88.0 5.0 3.0
1330035 2030035 2230035 3�h 3 3.068 3.260 3.500 0.216 0.120
85 80 78.0 83_0 88.0 5.0 3_0
1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120
3 X 100 80 78.0 83-0 88.0 5-0 3.0
1330050 2030050 2230050 �Ox 5 3 3.068 3.260 3.500 0.216 0.120
125 80 78-0 83 0 88.0 5-0 3.0
1330060 2030060 2230060 6 3 3.068 3.260 3.500 0216 0.120
150 80 75.0 83_0 8B_0 5_0 3_0
1330080 2030080 2230080 8 3 3.068 3260 3.500 0216 0.120
200 30 78.0 fi3 0 88.0 5.0 3 0
1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120
100 100 1020 108.0 114.0 6.0 3.0
1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120
4 X 12i 100 1020 108.0 114.0 6.0 3.0
1340060 2040060 2240060 ���a 6 4 4.026 4.260 4.500 0.237 0.120
150 100 102.0 108.0 114.0 G.0 3.0
1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120
200 100 102-0 108 0 114 0 6 0 3.0
- 2060060 2260060 6 4 6.065 6.351 6.625 0.280 0.134
6 x 150 l0u 155.0 1G1.5 168.3 7.1 3.G
- 2060080 2260080 �5C'% 8 4 6.065 6.357 6.625 0.280 0.134
200 100 155.0 161.5 165.3 7.1 3.0
- 2080080 - 8 x 8 4 1.981 8.329 8.625 0.322 0.148
200 r. 200 100 203 0 217_.0 21�.0 8.0 3.0
NOTE:Tee-Lets are manufactured to fit size-on-size,that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting,
a slight gap of approximately�/3z"will appear along the longitudinal centerline of the header. For example,a 1"x 2-2�/z"Tee-Let,is a 1"outlet fitting manufactured to fit perfectly on the 2"header size listed,
while leaving a Ysz"gap along the longitudinal centerline of the 2Yz"size.If a perfect fit is required for a 2Yz"header pipe,then a 1"x 2Yz-3"Tee-Let would be ordered.Size consolidations are employed ro
reduce inventory and provide for greater flexibility.
PAGESOFS
Merit°Tee-Lets & Drop Nipples For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, ;'
Rev.os.os.o�oos go to www.anvilslar.com or contact your local AnvilStar representative �!Z�� ��V�L
-
Concentric Reducers �Produ�A�sntaa!"TM
(�z�� ���L Cast Iron Threaded Fittings Class 125 (Standard) Submit�al Sheet
�BA
V� �� ��
FM -
APPROVED � - - -- -
For Listing/Approval ��'
details contact your --
AnvilStarT"^Representative.
� �
Size p g Weight Size p g Weight
black black
NPS/DN NPS/DN In./mm In./mm Ibs./k NPS/DN NPS/DN In./mm In./mm Ibs./k
3�4 ��2 5�6 �9�16 �.4 ���4 �3�16 2��8 �.8
20 15 16 40 0.1� � 32 22 54 0.81
■�/2 >>/ib l��/is 0.54 50 l�/2 �/a 23/ib 2
1 15 17 43 0.24 (�ont.) 40 22 56 0.9
25 ■3/a �/i b 1�/z 0.63 1 Y2 3/a 2 3.1
20 11 38 0.29 pyz 40 19 5'I 1.4
��2 9�16 �5�8 �.84 65 2 � 29�16 3
15 14 91 0.38 50 25 65 1.4
1�/a 3/a 1 2�/a l.l 3/a 15/ib 2�/z 4.3
32 20 25 S4 0.49 20 24 64 2
1 15/i a 2�/a 1.l 3 2 1�/i a 23/n 4
25 24 54 0.44 80 50 2I 70 1.8
�h Yz 15/a 1 2�/2 15/i 6 213/i 6 4.4
15 13 41 0.45 65 24 73 2
3/4 �/2 15/e 1.2 2 13/16 215/16 6.5
1�/2 20 13 41 0.54 50 30 75 2.9
40 1 Y2 13/a 1.5 q 2�/s 13/i 6 3�/s 7.8
25 13 44 0.68 lOG 65 30 !9 3.5
1�/a 1 2�/a 1.5 3 1�/i 6 3�/a 7
32 25 57 0.66 80 27 79 3.2
Yz 5/e 2 2 5 4 1�/i 6 3S/i e 10
15 16 Sl 0.91 12; 100 27 84 4.8
2 3/a 3/a 2 1.9 4 1 Ys 3�/i e 14
50 20 19 51 0.86 6 100 29 8I 6.3
1 3/a 2 1.8 1�0 5 1 Ys 39/i 6 16
25 19 Sl 0.83 125 29 90 1
8 6 1 Ya 3�/a 29
200 150 32 93 13
■hex end
� � � �
Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes
manufactured in accordance with ASME-B16.4 (except plugs '/a NPS - 12NPS (8 - 300 DN), are included in the "List of
and bushings, ASME B16.14�. Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by
Federal Specifications, WW-P-501(except plugs and bushings the Underwriters' Laboratories, Inc.
WW-P-471).
NOTE:See the Technical Data section for pressure-temperature ratings. See AnvilStar Web site for the most current Listings and approvals.
.� �. � � . .�
Project:
Date: Phone:
Architect/Engineer:
Contractor:
Address:
Notes 1:
Notes 2:
Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, /��������
REV.03.03.06-0011 go to www.anvilstar.cam or contact your local AnvilStar representative ll ,
90° Elbow - Strai ht ��StarTM
� Fire Products Division of Anvil`Intemational
(�z�� ���L Cast Iron Threaded Fittings Class 125 (Standard) Submit�al Sheet
uL FM LC �
APPROVED � �
For Listing/Approval � ,y�
details contact your '�
AnvilStarT"^Representative.
I � �
Weight
Size A B
black galv.
--B—� NPS/DN In./mm In./mm Ibs./kg Ibs./kg
'�A—'I �/a �/z 13/ie 0.16 O.0
I i U,07 ����
3�8 9�16 �5�16 0.25 �.26
}
T------'- - 10 19 24 0.11 0.12
g i j i_ �/2 >>/i6 l�/a 0.4 0.41
j— _---_- __-- 15 17 29 0.18 0_l9
� 3/a �3/i 6 15/i s 0.6 0.61
20 22 33 027 0.28
� �5�16 1�/2 0.92 0.95
25 24 38 0.42 0.43
1�/a 1�/e 13/a 1.4 1.5
32 29 44 0 65 0-66
1�/z �5�16 115/i s 2 2
40 33 49 0.88 0.91
Z �9�16 2�/a 3.1 3.2
�o ao 5> >4 � 5
2Yz ��3I16 2��/is 4.9 5.1
65 47 68 22 23
3 Y3�16 3�/a 1.2 7.4
80 56 79 3.3 3.4
4 2��/ib 313/i6 12 13
100 68 98 5.5 S I
5 35/�6 4�/2 21 —
125 84 114 10 —
6 3�/a 5�/a 31 33
150 9E3 130 14 15
B 53�16 69�16 65 67
200 132 1G7 29 30
� � � �
Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes
manufactured in accordance with ASME-B16.4 (except plugs '/a NPS - 12NPS (8 - 300 DN), are included in the "List of
and bushings, ASME B16.14�. Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by
Federal Specifications, WW-P-501(except plugs and bushings the Underwriters' Laboratories, Inc.
WW-P-471).
NOTE:See the Technical Data section for pressure-temperature ratings. See AnvilStar Web site for the most current Listings and approvals.
.� �. � � . .�
Project:
Date: Phone:
Architect/Engineer:
Contractor:
Address:
Notes 1:
Notes 2:
Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, /��������
REV.03.03.06-001 go to www.anvilstar.cam or contact your local AnvilStar representative ll ,
�
� � � �
—
� — �' . ��
Fig. 68 - Wide Throat Top Beam "C" Clamp w/Locknut
Size Range—3/8" thru 3/4" rod
Function — For attachment to structural shapes requiring
wider throat especially under roof with bar joist construction.
This clamp may be used in the set screw down position only.
Approvals— Conforms to Federal Specification
WW-H-171 E,Type 23 and Manufacturers Standardization
Society SP-69,Type 19.
Finish — Plain
Note—Available in Electro-Galvanized finish.
Order By— Figure number, rod size and finish
Note— Do not over tighten set screw.
Dimensions •Weights
Rod Max. Rec. Approx.
Size Load Lbs. Wt./100
3/8 400 34
1/2 500 50
5/8 600 53
3/4 800 86
��"�
�•' � �
-' J
,- ,.
:;
��� ' �_ �
._.,
��" � C ;.
.�"�.� �-.?
<"� -�", � �_
�_:�
``` � �-�, �—:a
��'� i
�'" �
�- � �_.1
. �� � � � � �-��
� '�
`��`.� � ,� L �--)
`l�.j�.' � �_;�
ti-'j
I �-
I � ' '�� `=
� i j �,\
I � '
� � I
I ' �
� � J
/� i i
�"� i
�-� i
� �-��,.
i ,.
<"� %
�-'� -,
��
,, •�
., -�
'��
,, •� ,,
�,�.- ,.
\� �
OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE•CORONA,CA 92879•PH: 951 J37.5599•fAX: 951 J37.0330
� CUSTOMER SERVICE•800J86.5266
www.tolco.com
SAMMYS° FOR WOOD
� ° . - . . . � . . .
-�� . • .,
Not less than Wood Flooring
z°oommai W�dm •No pre-drilling required.
11-�►
� •Quick to install using the Sammy
� Not iess man Nut Driver with an 18V cordless
� s°oom�nai � drill/driver.
thickness(2-1/2")
(depth or side Wood Jaist
�� ofver�icai memeer) _ _ _ ,, , •Saves time from traditional
// methods.
�� Double Sheehock�
ce�r�e •Reduces installation costs.
� i f •Made in the U.S.A.
. ��
� � •
, � � �
,I �� � �:�
�� ,
� - �
��
^.`L—
— �—
�r� ,
Watch a video demonstretion at
m www.itwbuildex.com
� . � �
1l4" 8002957 GST 100 114 x 1" 210 (7116"OSB) Z5 125
670 (3l4"Ply)
1/4" 8003957 GST 200 114 x 2" 1760 (Fir) 25 125
1l4" 8004957 GST 300 1l4 x 3" 2060 (Fir) 25 125
�� 210 (7116"OSB)
� 3/8" 8007957 GST 10 114 x 1" 300 25 125
670 (314"Ply)
�,�`, 0 318" 8008957 GST 20 114 x 2" 1760 (Fir) 850 1475 25 125
�� 3/8" 8068925 GST 20-SS 114 x 2" 1760 (Fir) 850 25 125
��e, 3l8" 8009925 GST 25-380 318 x 2-112" 2113 (Fir) 1500 25 125
#14 Black a� � 3/8" 8010957 GST 30 114 x 3" 2060 (Fir) . 1500 1475 25 125
Nut Driver 318" 8069925 GST 30-SS 1l4 x 3" 2060 (Fir) 25 125
Part#8113910 3/8" 8011925 GST 40 1l4 x 4" 2180 (Fir) * 25 125
112" 8013925 GST 2 114 x 2" 1760 (Fir) 25 125
1/2" 8014925 GST 2.5-380 318 x 2-112" 2113 (Fir) 25 125
1/2" 8015925 GST 3 114 x 3" 2275 (Fir) 25 125
#14 SW Red
Nut Driver
Part#8114910
� � �S
MADE IN U.S.A como�',em
SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into
contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations.
• . � • �. - � . . � �- .
�
� � • � . . .
-
, – •� . • ��.
Fig. 98 - Rod Stiffener Component of Sta�tp of �OUS LISTED
California OSHPD A roved V
Seismic Restraints System
Size Range—Secures 3/8" thru 7/8" hanger rod
Material —Carbon Steel "a
k:_;
�_;
Function — Secures channel to hanger rod for vertical seismic bracing. r-,;
t--:
Approvals— Underwriters Laboratories Listed in the USA (UL) and "r ='
�;,.,_
Canada (cUL). Included in our Seismic Restraints Catalog a�proved �� � ��_:;; � � �_:..
bv the State of California Office of Statewide Health Planning and ', � " r`'�'
Development (OSHPD). For additional load, spacing and placement \\ ', ` �h " ,
information relating to OSHPD projects, please refer to the TOLCO ', 1�\; ,
Seismic Restraint Systems Guidelines ' � � '' '
Finish — Electro Galvanized ',
Note—Available in HDG finish or Stainless Steel materials. '
.,,✓
Order By— Figure number
Fig. 99 - All Thread Rod Cut to Length
Size Range— Secures 3/8" thru 7/8" rod in Dimensions
1" increments Rod Max. Rec. Load Lbs.
Material —Carbon Steel Size For Service Temps
Maximum Temperature—750°F 650°F 750°F
Finish — Plain 3/s sio 540
1/2 1130 1010
Note—Available in Electro-Galvanized and 5/s 1810 1610
HDG finish or Stainless Steel materials. 3/a 2�10 2a2o
Order By— Figure number, rod diameter, rod �/8 3��0 3360
length and finish
Fig. 100 - All Thread Rod Full Lengths
Size Range—Secures 3/8" thru 7/8" rod in
10' lengths
Material —Carbon Steel
Maximum Temperature—750°F
Finish — Plain
Note—Available in Electro-Galvanized and
HDG finish or Stainless Steel materials.
Order By— Figure number, rod diameter
and finish
i
Dimensions •Weights
Max Rec. Load Lbs.
Rod For Service Temps Approx.
Size 650°F 750°F Wt./100
1/4 240 215 12
3/8 610 540 29
1/2 1130 1010 53
5/8 1810 1610 84
3/4 2710 2420 123
7/8 3770 3360 169
1 4960 4420 222
1�/a 8000 7140 360
1�/2 11630 10370 510
m OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE•CORONA,CA 92879•PH: 951 J37.5599•fAX: 951 J37.0330
CUSTOMER SERVICE•800J86.5266
www.tolco.com
�
� � • � . . .
-
- ■ - . ��
Fig. 200 - "Trimline" Adjustable Band Hanger � uL W��,STEo
Size Range — 1/2" thru 8" pipe
.F�o
Material — Carbon Steel, Mil. Galvanized to G90
specifications
Function — For fire sprinkler and other general piping - `:-�_�
purposes. Knurled swivel nut design permits hanger
adjustment after installation.
Features — _ -_
• (1/2" thru 2") Flared edges ease installation for �'"� %�
all pipe types and protect CPVC plastic pipe from
abrasion. Captured design keeps adjusting nut ' g - �,
from separating with hanger. Hanger is easily s �'
installed around pipe.
• (2'/2" thru 8" Spring tension on nut holds it A � �' �
securely in hanger before installation. Ad�usting
nut is easily removed.
Approvals — Underwriters' Laboratories listed (1/2"
thru 8") in the USA (UL) and Canada (cUL) for steel
and CPVC plastic pipe and Factory Mutual Engineering i,.-
Approved (3/4" thru 8"). Conforms to Federal -' ���T�RU 2 ir�cH PiPE -�' z �rz T�RU s ir�c�aiRE
Specifications WW-H-171 E, Type 10 and Manufacturers
Standardization Society SP-69, Type 10.
Maximum Temperature—650°F �
Finish — Mil. Galvanized. For Stainless Steel materi-
als, order TOLCOT"" Fig. 200WON. : '�'� ` L��,�
Order By— Figure number and pipe size �
�4
�I'I ' � 1
i � ;r �
t � �
- - ��;l �
�
� f ��, ! ��
��;;:- .:�..,:
Dimensions •Weights
Pipe Rod Size Max. Rec. Approx.
Size Inch Metric '°` B Load Lbs. Length
1/2 3/8 8mm or 10mm 3�/s 25/a 400 11
3/4 3/8 8mm or 10mm 3Ya 2�/z 400 11
1 3/8 8mm or 10mm 33�8 25/a 400 12
1�/a 3/8 8mm or 10mm 33/a 2�/s 400 13
1�h 3/8 8mm or 10mm 3�/a 2�/a 400 14
2 3/8 8mm or 10mm 4�/z 3 400 15
2�/z 3/8 10mm 55/a 4�/s 600 27
3 3/8 10mm 5�/s 4 600 29
3�h 3/8 10mm 73/a 5�/a 600 34
4 3/8 10mm 73/a 5 1000 35
5 1/2 12mm 9�/a 6Ya 1250 66
6 1/2 12mm 10�/a 63/a 1250 73
8 1/2 12mm 13�/a 83/a 1250 136
OFFIC�/MANUFACTUWNG FAC7LITY•1375 SAfv1P5CN A�E•Q.F�NPy CA 92879•R-t 951.737.5599•FAX 951.737.a330
�� CiJSTOMH�S�/ICE•800.786.5266
www.tolco.com