Loading...
HomeMy WebLinkAboutDRB130053 PLANS APPROVEDTOWN OF VAIL/ Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improve- ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at .vww.vailgov.com under Vail Information — Town Code Online. All projects requiring de- sign review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building per- mit is issued and construction commences. Fee: $250 for Multi - Family /Commercial $20 for Single Family /Duplex Single Family Description of the Request: Duplex ✓ Multi - Family Commercial Addition of copper gutters and downspouts with heat trace. Physical Address: 123 Willow Place Unit #3, Vail, CO Parcel Number: 210108259003 Property Owner: Richard Mailing Address: Owner's Signature: rly Graham (Contact Eagle Co. Assessor at 970- 328 -8640 for parcel no.) Phone: (o) 0 - b) S - Primary Contact/ Owner Representative: Mark Donaldson or Chris Juergens/VMDA Mailing Address: PO Box 5300 Avon, CO E -Mail: markd @vmda.com For Office Use Only: Cash_ CC: Visa / MC Last 4 CC # Fee Paid: Meeting Date: Planner: Zoning: Location of the Proposal: Lot: a Phone: 970- 949 -5200 or Mark's Cell 390 -5300 Fax: 970- 949 -5205 Exp. Date. Auth # Check # Received From DRB No.: Project No: _ Land Use: Block: Subdivision: PROPOSED MATERIALS Building Materials Type of Material Color Roof N/A N/A Siding N/A N/A Other wail Materials N/A N/A Fascia N/A N/A soffits N/A N/A Windows N/A N/A Window Trim N/A N/A Doors N/A N/A Door Trim N/A N/A Hand or Deck Rails N/A N/A Flues N/A N/A Flashing N/A N/A Chimneys N/A N/A Trash Enclosures N/A N/A Greenhouses N/A N/A Retaining Walls N/A N/A Exterior Lighting N/A N/A Other Gutters and Downspouts Copper Notes: Please specify the manufacturer's name, the color name and number and attach a color chip. Ton QF1'dliL JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER The applicant must submit written joint property owner approval for applications affecting shared ownership properties such as duplex, condominium, and multi- tenant buildings. This form, or similar written correspondence, must be com- pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con- dominium or multi- tenant building. All completed forms must be submitted with the applicants completed application. I, (print name) Anthony Mayer, HOA Board President a joint owner, or authority of the association, of property located at 123 Willow Place Lot 5, Block 6, Vail Village, 1 st Filing , provide this letter as written approval of the plans dated 3126112 by Victor Mark Donaldson Architects which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address not- ed above. I understand that the proposed improvements include: Remodel & expansion of Unit #3 Summers Lodge Condominium resulting in an increase of approximately 570 SF GRFA and expansion of existing balcony areas (as illustrated on the VMDA plans noted). The expansion areas also include consuming some Common Area and some over existing Unit #3 balcony areas. The 570 SF GRFA is being consumed from approximately 1,430 SF of available GRFA of the Summers Lodge Homeowner's Association, with 860 SF GRFA remaining. VC14=Mm'- _V1 V_ V I , - 1. (Signature) 0-119-13 (Date) Additionally, please check the statement below which is most applicable to you: I understand that minor modifications may be made to the plans over the course of the review process to ensure Com- phancq, with the Towns applicable codes and regulations (Initial here) I understand that all modifications, minor or otherwise, which are made to the plans over the course of the review pro- cess, be brow ht to my attention by the applicant for additional approval before undergoing further review by the Town. (Initial here a 0 0 3 N 3 6 i 0 , r-1n i vn i iivc;W ' SHALL MATCH EXISTING filsociF FL�N 5CALE: 1 / 4" = P - 0" L Oomzimucinom n- NA "T ON ARCHITECTS 090 WEST BEN MARKROAD SUITE 207 BOX 5300 AVON, CO 81620 970.949.5200 vmda @vmda -com FAX 949.5205 Lu V cn 5 Z Lu D Zr*- 0� �o00 00 W U 4 ad WoC 0 ��U 0 0 4c Z (n w J j Q 2 ad � CD Design Review Staff Approval OF � By Warren Campbell at 6:01 am, Mar 26, 2013 TOWN �j I22) 7 � I^l PARTIAL EAST ELEVATION 50ALE: 1/ 4" = I' - O" Design Review Staff Approval By Warren Campbell at 6:01 am, Mar 26, 2013 TOWN OF VAIL 51k ig ON ARCHITECTS 0 9 0 WEST BENCHMARK ROAD SUITE 207 BOX 5300 AVON, CO 81620 1-411 970.949.5200 'EGK vmda @vmda.com FAX 949.5205 -Q, II PLYWOOD ILYWOOD W 75 Z � Wzti 0T- LCD z oo 0p U Q w 00 moo 0 J U J Cn J Z W > 0 I LINE OF BUILDING JI SETBACK I � i I I NEW ROOF ROOFINGI SHALL MATCH EXISTING \ I 1- I � NEW TIMBER RIDGE S BEAM TAILS SHALL MATCH EXISTING 8180'-4 "o - -- - T.O. DECK ALL NEW OVERHANGS, SIDING TRIM 4 WOOD FASCIA SHALL MATCH EXISTING NEW WINDOWS, DOORS $ WOOD TRIM SHALL MATCH EXISTING 42" HIGH NEW DECK RAILING SHALL MATCH EXISTING T.O. PLYWOOD NEW DECK TRIM SHALL MATCH EXISTING NEW TIMBER KNEE BRACES SHALL MATCH EXISTING EXISTING STONE PLANTER, NO CHANGE 8156' -6110 _ T.O. SLAB Location 2 & 3 110' of heat tape NEW ROOFIN5 5HAL MATCH EXISTING TEXTURE 4 COLOR �J 0 ® ■■ I00 ■■ -N� !I!!\ ■■ wlq ter:= _ .. 1 11�11C�1� � f�■ '� I LINE OF BUILDING SETBACK I Location #4 EXI5TIN 0 NO CHANGE 22' of heat tape r LNEPq 5TUC00 SHALL MATCH EXISTING TEXTURE 6 COLOR Pro c 8 3 06.2 .46.2 0 EXISTING CHIMNEY NO CHANGE 146 0-0 i NEW STUCCO SHALL MATCH EXISTING TEXTURE 4 COLOR d heat tape connections PARTIAL SOUTH ELEVATION 50ALE: 1 / 4" = 1' - O" 0 Location #5 130' of heat tape 42" HIGH NEW DECK RAILING WOOD SIDING 4 STAIN SHALL MATCH EXISTING OIL 8180' -4" T.O. DECK ALL NEW OVERHANGS, 51DING TRIM 8 WOOD FASCIA SHALL MATCH EXISTING NEW WINDOWS, DOORS $ WOOD TRIM SHALL MATCH EXISTING 42" HIGH NEW DECK RAILING SHALL MATCH EXISTING Ilk 8168' -8" \-F T.O. PLYWOOD NEW DECK TRIM SHALL MATCH EXISTING NEW TIMBER KNEE BRACES SHALL MATCH EXISTING EXISTING GRADE NO CHANGE J� 8156' -6" T.O. SLAB Design Review Staff Approval By Warren Campbell at 6:02 am, Mar 26, 2013 TOWN OF VAIL V ON ARCHITECTS 090 WEST BENCHMARKROAD SUITE 207 BOX 5300 AVON, CO 81620 970.949.5200 vmtla @umda.com FAX 949.5205 W V � Z� Wz� DOT- LO l) z 00 Wv< Op uqV w0 �_U b J O J U) J_ Z Q W 7 Q > U) O O C� O PARTIAL WEST ELEVATION 50ALE: 1 / 4" = 1' - O" _ 8150' -4" T.O. DECK 42" HIGH NEW DECK RAILING SHALL MATCH EX15TINO T.O. PLYWOOD NEW DECK TRIM 5HALL MATCH EXI5TIN(5 NEW TIMBER KNEE BRACE5 SHALL MATCH EXI5TIN5 _ OIL 5156' -6" T.O. SLAB Design Review Staff Approval OWN �� By Warren Campbell at 6:02 am, Mar 26, 2013 V ON ARCHITECTS 090 WEST BENCHMARK ROAD SUITE 207 BOX 5300 AVON, CO 81620 970.949.5200 vmtla @umda.com FAX 949.5205 W V� G Z� Wz� 0 0 C) z oo W�a 0 �wry 00 �0U b J O J U) J_ Z Q w Q ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) Q RECESSED OR SURFACE DOWNLIGHT Q I WALL MOUNTED LIGHT FIXTURE Aa RECESSED FLUOR. LIGHT FIXTURE Aa SURFACE FLUOR. LIGHT FIXTURE © FIXTURE DESIGNATIONS: Q UPPER CASE - FIXTURE TYPE QQ LOWER CASE - SWITCH DESIGNATION ® SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP EWC FLUORESCENT STRIP FIXTURE GND TRACK LIGHT AS NOTED OR SCHEDULED GFI WALL WASHER �0 POLE- MOUNTED FIXTURE NIC POST (BOLLARD) FIXTURE ® STEP LIGHT ® CEILING OR WALL MOUNTED EXIT LIGHT UG EMERGENCY BATTERY LIGHTS WP DUPLEX RECEPTACLE @ 18" UNLESS NOTED XFMR DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED QQ FLUSH FLOOR DUPLEX RECEPTACLE ® SPECIAL OUTLET AS NOTED O DUPLEX RECEPTACLE HALF - SWITCHED @ 18" UNLESS NOTED ® TELE -POWER POLE { MULTI - OUTLET PLUG STRIP D JQ JO I JUNCTION BOX IN FLOOR, CEILING OR IN WALL 8 ♦ COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL k-B TELEVISION OUTLET 2 TELEPHONE BACKBOARD 2 CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING --)P- CIRCUIT HOMERUN — — — CONDUIT RUN BELOW FLOOR OR GRADE ] CONDUIT STUB -UP - CAP & MARK " LIGHT SWITCH AT 48" UNLESS NOTED 1500 SUBSCRIPTS: 2 = 2 -POLE SWITCH 3 3 = 3 -WAY SWITCH 4 = 4 -WAY SWATCH 6000 K = KEY - OPERATED SWITCH SOH TO = THERMAL OVERLOAD SWITCH P = SWITCH WITH PILOT LIGHT ❑D DIMMER SWITCH W/ WATTAGE 0 PUSHBUTTON CONTROL STATION PC PHOTOELECTRIC CELL TS TIME SWITCH QT THERMOSTAT AT 60" UNLESS NOTED eDIVISION 15 EQUIPMENT FOOD SERVICE EQUIPMENT COMMUNICATION SYSTEM QS QS I SPEAKER IN CEILING OR WALL �V I VOLUME CONTROL AT 60" UNLESS NOTED OM OM -I MICROPHONE OUTLET IN FLOOR BOX OR WALL OC -I CALL -IN SWITCH © PROGRAM BELL Q INTERCOM QQ CLOCK Q AMPLIFIER ABBREVIATIONS AC ABOVE COUNTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AL ALUMINUM CU - COPPER DESIG. - DESIGNATION EM - EMERGENCY EMP ENERGY MANAGEMENT PANEL EWC ELECTRIC WATER COOLER GND - GROUND GFI GROUND FAULT INTERRUPTER NF NOT FUSED NIC NOT IN CONTRACT NL NIGHT LIGHT NTS NOT TO SCALE UG - UNDERGROUND WP - WEATHER PROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE (D V OF DEVICE AFF OR AFG FIRE ALARM SYSTEM 00 FACP FIRE ALARM CONTROL PANEL ANN I FIRE ALARM ANNUNCIATOR PANEL Q FIRE ALARM PULL STATION �W�UU LL . � P L_ ALARM HORN OR SPEAKER �: COMBINATION HORN /STROBE OR SPEAKER /STROBE • H THERMAL HEAT DETECTOR • I SMOKE /IONIZATION DETECTOR • P PHOTOELECTRIC SMOKE DETECTOR • H/P HEAT /PHOTOELECTRIC SMOKE DETECTOR IS MR DUCT DETECTOR ( SPRINKLER SYSTEM FLOW SWITCH 1111111111+ SPRINKLER SYSTEM TAMPER SWITCH ED STROBE QD SMOKE /FIRE DAMPER CONNECTION "I REMOTE INDICATOR LIGHT SECURITY SYSTEM DC CONTACT DOOR SWITCH IN JAMB OR HINGE INTRUSION MOTION DETECTOR AS SPECIFIED, CORRIDOR /ROOM CORR �K KEY- OPERATED ACCESS SWITCH SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS —� DISCONNECT SWITCH --f— FUSES CIRCUIT BREAKER CURRENT TRANSFORMER �7 TRANSFORMER METER ® MAGNETIC MOTOR STARTER ❑1 DISCONNECT SWITCH 1iNir PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED 1-1--� SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION BOARD TRANSFORMER GROUND CIRCUIT BREAKER Q MOTOR OUTLET ATS 1 AUTOMATIC TRANSFER SWITCH ELECTRICAL SPECIFICATIONS A. General Requirements 1 SCOPE: Furnish all materials and labor required to execute this work as indicated on drawing and as specified, as necessary to complete the contract. Electrical work shall include, but not limited to, these major items: A. Complete wiring system for new lighting and power as shown, including new panelboards, new conduits, new wires, new wiring devices, new control devices, etc. for a complete lighting and and power system. a. Complete feeder(s) installation as required for new and /or electrical apparatus as shown on single line diagram and drawings. b. Complete branch circuit wiring required for the connection of emergency lighting and exit signs to existing emergency stand by power system. 2. Complete provision, installation and connection of lighting fixtures, exit signs and lamps as specified and as shown on drawings. 3. Fire alarm system will be by others. Coordinate connections to the hood & duct detection 4. Complete connection of HVAC /Plumbing motor(s), water heater(s), equipment, etc. furnish by mechanical - refer to both electrical and and mechanical drawing for scope and work and additinal infor- mation. 5. Provide grounding and bonding Facilities. 6. Complete all electrical demolition as required. 7. Core drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard procedures and contractor shall have written approvals from building owner prior to start of any work. 8. Test of entire system and work. 9. Operating, Maintenance and identification instructions manuals, if any. 10. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- tions, examinations and fees or charges necessary for execution and completion of electrical work. 11. REGULATIONS AND CODES: A. Applicable codes: National Electric Code (1999) Conform to the prevailing edition and amendments thereto of the Town of Vail Electrical Code, pertinent NFPA publications and to the requirements of Federal, State or other City agencies having jurisdiction. 12. SHOP DRAWINGS AND SUBMITTAL: PANEL HOUSE PROJECT: SUMMERS LODGE ENGINEER: SOH PROJECT #: 13010 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 400A MLO TYPE: EXISTING SIEMENS AIC: 10K O N 00 4—a O (1) C13 r L O PHASE W. C O O O O O Q U oo�(3'E �N x O �W�UU LL . � P L_ N J NN i oo N M co 05 w V U =O (CS � C3 wU) rn -a U W C:) C �W00 O PHASE cc� � G ' p X X O C0 DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION SbNAL (D V O O O � J Q O BOILER PUMP 1500 J 20 2 1 2 3 100 6000 2/1/13 PERMIT DRAWINGS ELEVATOR " 1500 3 4 6000 Checked By: SOH AEC BOILER PUMP ELEC LEGEND, 11500 GRAM, S PEC S 20 12 1,60 1 of 1 5 6 1 6000 " 1500 7 18 11 20 1540 1 MECHANICAL ROOM REC BOILER PUMP 1500 20 2 9 10 1 20 1000 2ND FLOOR HALL " 1500 11 12 1 20 1000 2ND FLOOR HALL HEATTRACE 1250 20 2 13 14 1 20 540 ROOF " 1250 15 16 1 20 540 ROOF WEST CONTROL PANEL 500 20 1 17 18 1 20 500 HALL LIGHTS RH3 & 4 500 20 1 19 20 1 20 500 HEATTAPE ELEVATOR SUMP PUMP 500 20 1 21 22 1 20 500 TOP HATT RECEPTACLES 1080 20 1 23 24 1 20 500 OUTSIDE WALK LIGHTS BASEMENT HALL 500 20 1 25 26 1 20 360 TELEPHONE BASEMENT HALL 500 20 1 27 28 1 20 750 LIGHTING MECHANICAL ROOM 500 20 1 29 30 1 20 500 SUMP PUMP FIRE ALARM 500 20 1 31 32 1 20 500 STAIR TOWER LIGHTS STAIR TOWER LIGHTS 1000 1 20 1 33 34 1 20 360 IRECEPTACLES OFFICE LIGHTS 500 20 1 35 36 0 SPACE LIGHTING AND RECEPTACLEE 1040 20 1 37 38 3 100 2940 HOUSE SUB PANEL EMERGENCYLIGHTS 500 20 1 39 40 2940 BASEMENT HALL 500 20 1 41 42 2940 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.89 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 9250 26 9250 26 RECEPTACLES 5460 15 5460 15 MECHANICAL 39820 130 44320 144 KITCHEN 0 0 0 0 TOTAL 54530 171 59030 185 PANEL HOUSE SUB PROJECT: SUMMERS LODGE ENGINEER: SOH PROJECT #: 13010 VOLTAGE: 120/208V, 3P, 4W MOUNTING: SURFACE MAINS: 80A MLO TYPE: MATCH HOUSE PANEL AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION HEATTAPE 1250 20 2 1 2 2 20 600 HEATTAPE LOCATION #1 120' 30 mA GFI 1250 3 4 600 30 mA GFI HEATTAPE 1250 20 2 15 6 2 20 660 HEAT TAPE LOCATION #2,3 &4 30 mA GFI 1250 7 8 660 30 mA GFI 132' HEATTAPE 1250 20 2 9 10 2 20 650 HEAT TAPE LOCATION #5130' 30 mA GFI 1250 11 12 650 30 mA GFI SPACE 0 13 14 0 SPACE SPACE 0 1 15 16 0 SPACE SPACE 0 17 18 0 SPACE SPACE 0 19 20 1 0 SPACE SPACE 0 21 22 0 SPACE SPACE 0 23 24 0 SPACE 0 25 26 0 0 27 28 0 0 129 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 1 41 42 0 LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.85 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 0 0 0 0 RECEPTACLES 0 0 0 0 MECHANICAL 11320 37 11945 39 KITCHEN 0 0 0 0 TOTAL 11320 37 11945 39 13. CONDUIT AND WIRE: A. CONDUCTOR SIZES AND TYPES: Use only copper wire, 600 volt insulation, stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. In sizes #1 and smaller, use types TW, THHN or THW. In sizes larger than #1, use THW or XHHW. Use type THHN for wires entering or passing through fluorescent lighting fixtures. B. MC cable permitted per local codes. 14. ELECTRICAL DEVICES A. Convenience receptacles will be 20 amp, commercial grade decora style. Finish per owner or architect. B. Light switches will be 20 amp, commercial grade, decora style. Finish per owner or architect. C. Dimming switches will be a minimum of 600w or as noted. Provide decora style, finish per owner or architect. D. All mounting heights will conform to ADA guidelines. Typical receptacle heights will be +18 "AFF and switch heights will be +46 "AFF unless noted otherwise. E. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. 15. SUPPORT A. Support all electrical equipment independent of accessible ceilings as required by NEC. 16. ELECTRICAL BOXES A. At fire rated wall space electrical boxes at opposite sides of the wall no less than 24" horizontal distance. B. When phone, TV & power receptacles are shown on plan next to each other. Locate respective receptacles next to each other on site with no more than 1" seperating cover plates. TO UTILITY TRANSFORMER TEMPERATURE & MOISTURE SENSOR AT ROOF TEMPERATURE & MOISTURE SENSOR AT GUTTER 120V, 1 -PHASE (2 #12 CU, 1 ; HOUSE PANEL (3 #18 CU) 1/2 "C - 500' MAX RUN #APS -3C SNOW CONTROLLER - NEMA 3R 80A3P CONTACTOR, 120V COIL, NEMA 4X ENCLOSURE HOUSE SUB PANEL L -1 HEAT TRACE CONTROL NO SCALE NEW WORK IS CLOUDED RELOCATE (3) 20A2P HEAT TRACE CIRCUITS TO NEW PANEL TO MAKE ROOM FOR NEW 80A3P CIRCUIT BREAKER LOCATE NEW PANEL PER BUILDING MANAGER. REVIEW HEAT TRACE CIRCUIT ROUTING WITH BUILDING MANAGER BEFORE ROUGHIN. / PANEL HOUSE SUB (4 #3 CU, #6 CU G)1 -1/4 "C PROVIDE PRICING OPTION FOR HEAT TRACE CONTROL PER DETAIL THIS SHEET. PANEL HOUSE 80/3 <10K AIC (4 #500 MCM CU, #1/0 CU G)4 "C I I (3)400A LPS 400/3 HOUSE MAIN DISCONNECT 400A7 120/208V, 3P7 4W 42kAIC ELECTRICAL ONE -LINE DIAGRAM A. Contractor shall submit shop drawings for engineer review and approval. NO SCALE B. Shop drawing submittal shall include: 1. Panelboard(s). O N 00 4—a O (1) C13 r L O U LO vU 00 00 W. C O O O O O Q U oo�(3'E �N x O �W�UU LL . � P L_ N J NN i oo N M co 05 w V U =O (CS � C3 wU) rn -a U W C:) C �W00 O ^U^1 FD cc� � G ' p X X O C0 O 0 �,40 REG /S) 177 SbNAL (D V O O O � J Q O w U W J J AEC PROJECT #:13010 DATE: ISSUE: 2/1/13 PERMIT DRAWINGS Drawn By: Checked By: SOH AEC ELEC LEGEND, ONE -LINE DIA- GRAM, S PEC S & DETAILS 1,60 1 of 1 © COPYRIGHT 2005 ARCHITECTURAL ENGINEERING CONSULTANTS. INC.