HomeMy WebLinkAboutB12-0571 Rev plans approved GENER,4L NOTES: ANDRESON RESIDENCE REMODEL JOB#0210-12 DESIGN CRITERIA: FLOOR LIVE LOAD: 40 PSF FLOOR DEAD LOAD: 15 PSF BASIC WIND SPEED(3 SEC GUST): 90 MPH WIND EXPOSURE: B SEISMIC DESIGN CATEGORY: � IBC/IRC EDITION: 2009 FOUNDATION DESIGN: 1. THIS FOUNDATION HAS BEEN DESIGNED BASED ON THE RECOMMENDATIONS SET FORTH IN GEOTECHNICAL REPORT#95248S BY ENGINEERING DESIGN WORKS,INC. CONSTRUCTION OF THIS FOUNDATION SHALL FOLLOW THE REQUIREMENTS FROM THIS REPORT. 2. DESIGN OF FOOTINGS IS BASED ON A MAXIMUM ALLOWABLE BEARING PRESSURE OF 2500 PSF. 3. RETAINING WALLS HAVE BEEN DESIGNED USING A LATERAL PRESSURE OF 70 PCF FOR THE"AT REST°EARTH PRESSURE CONDITION. REINFORCED CONCRETE: 1. CONCRETE DESIGN IS BASED ON THE MOST CURRENT PUBLICATION OF "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"(ACI 318). 2. STRUCTURAL CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 3. CONCRETE SHALL BE PROPORTIONED USING TYPE I-II SULFATE RESISTANT CEMENT. DO NOT USE ADMIXTURES CONTAINING CHLORIDE SALTS. 4. FOR COLD WEATHER CONCRETING PROCEDURES REFER TO THE"ACI MANUAL OF CONCRETE PRACTICE." 5. EXPANSION ANCHORS SHALL BE LOCATED NO LESS THAN 6 BOLT DIAMETERS FROM CONCRETE EDGES AND SPACED AT NO LESS THAN 12 BOLT DIAMETERS UNLESS NOTED OTHERWISE. 6. CONCRETE FLOOR SLABS ON GR,4DE SHALL HAVE SAWN OR TOOLED CONTROL JOINTS AT A MAXIMUM SPACING OF 12 FEET IN EACH DIRECTION. IF POSSIBLE,LOCATE CONTROL JOINTS ALONG COLUMN GRIDLINES. CONCRETE COVERAGE FOR REINFORCING STEEL(ACI 318-95): CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BAR THROUGH#18 BAR: 2" #5 BAR,W31 OR D31 WIRE,AND SMALLER: 1 1/2" CONCRETE NOT EXPOSED TO WEATHER NOR IN CONTACT WITH GROUND: a. SLABS,WALLS AND JOISTS(#11 BAR AND SMALLER): #14 AND NO 18 BARS: 1 1/2" #11 BAR AND SMALLER: 3/4" b. BEAMS AND COLUMNS: PRIMARY REINFORCEMENT,TIES,STIRRUPS,SPIRALS: 1 1/2" REINFORCING STEEL: 1. EXCEPT WHERE OTHERWISE NOTED,REINFORCING BARS SHALL BE GRADE 60 EXCEPT TIES,FIELD BENT BARS AND BARS TO BE WELDED WHICH MAY BE GRADE 40. ALL REINFORCING BARS SHALL CONFORM TO ASTM SPEC. 2. FOR BARS#8 AND SMALLER,LAP BARS 36 DIAMETERS AT SPLICES IN CONCRETE.DO NOT WELD OR USE MECHANICAL SPLICING DEVICES UNLESS APPROVED BY ENGINEER. 3. HORIZONTAL BARS SHALL BE CONTINUOUS OR LAPPED WITH CORNER BARS AT CORNERS. PROVIDE(2)-#5 BARS EXTENDING A MINIMUM OF 2 FEET BEYOND EDGE OF ALL OPENINGS OR STEPS. 4. EXTEND REINFORCING STEEL A MINIMUM OF 2 FEET THROUGH COLD JOINTS. COORDINATE ALL COLD JOINT LOCATIONS WITH ENGINEER. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM SPEC.A-185. LAP WELDED WIRE FABRIC A MINIMUM OF TN/O FULL MESH GRIDS. GENERAL REQUIREMENTS: 1. CHECK ALL DIMENSIONS AGAINST ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. CONTACT ENGINEER IF DISCREPANCIES IN DIMENSIONS ARE DISCOVERED. 2. THE STRUCTURAL DRAWINGS DESCRIBE THE COMPLETED STRUCTURE. THESE DRAWINGS HAVE BEEN PREPARED FOR THE USE OF A QUALIFIED CONTRACTOR WITH EXPERIENCE IN THE CONSTRUCTION SYSTEMS AND TECHNIQUES DESCRIBED. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING IN THE PROPER SEQUENCE,AS MAY BE REQUIRED TO ACHIEVE THE FINAL COMPLETED STRUCTURE. THE SEQUENCE OF CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTR,4CTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIONS(NOT IN CONTRACT). 3. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS,METHODS SEQUENCES AND PROCEDURES FOR CONSTRUCTION OF THIS PROJECT. NOTIFY STRUCTURAL ENGINEER OF ERRORS OR OMISSIONS IN THE CONSTRUCTION DOCUMENTS IMMEDIATELY. DO NOT PROCEED UNTIL ERRORS OR OMISSIONS ARE RESOLVED. COORDINATE REQUIREMENTS FOR ALL PENETRATIONS THROUGH STRUCTURAL MEMBERS WITH STRUCTURAL ENGINEER. JOBSITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. OBSERVATION VISITS BY THE STRUCTURAL ENGINEER ARE FOR DETERMINATION OF GENERAL COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. THIS OBSERVATION VISIT IS NOT AN INSPECTION. THE CONTRACTOR SHALL CONTACT THE ENGINEER AT THE APPROPRIATE TIME TO SCHEDULE THIS VISIT. 5. IF NEW CONSTRUCTION ADJOINS AN EXISTING STRUCTURE,THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS, ELEVATIONS AND ALL EXISTING CONDITIONS. UNDERPINNING AND SHORING OF EXISTING STRUCTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIGNS (NOT IN CONTRACT). 6. WHILE EVERY EFFORT IS MADE TO PROVIDE A COMPLETE AND ACCURATE SET OF CONSTRUCTION DOCUMENTS,ERRORS OR OMISSIONS MAY OCCUR. RELEASE OF THESE DRAWINGS ANTICIPATES CONTINUED COOPER,4TION AND COMMUNICATION BETWEEN THE CONTRACTOR,ARCHITECT AND ENGINEER TO PROVIDE THE BEST POSSIBLE STRUCTURE. ABBREVIATIONS LIST A.B. ABV. ADJ. ALT. ARCH. BLKG. BM. BM. PKT BRG. CANT. CLR. CMU COL. CONC. CONT. C.P. DWL. (E)- EA. EQ. EXP. EXSTG. F.D. FTG. G.B. G.L. � HDR. HORIZ. ANCHOR BOLT INFO. ABOVE JSTS. ADJACENT K.S. ALTERNATE LLV ARCHITECT LONGIT. BLOCKING LTWT. BEAM LVL BEAM POCKET MANF. BEARING (N)- CANTILEVER O.C. CLEAR � CONCRETE MASONRY UNIT REF. COLUMN REINF. CONCRETE SCHED. CONTINUOUS STL. CRIPPLE POST T DOWEL T•B• EXISTING T&G EACH TO EQUAL TOF EXPANSION TOW EXISTING TRANSV FLOOR DRAIN TRTD. FOOTING TS GRADE BEAM NP• GLUED LAMINATED VERT. GRID LINE VIF HEADER WP• HORIZONTAL W� INFORMATION JOISTS KING STUD LONG LEG VERTICAL LONGITUDINAL LIGHTWEIGHT LAMINATED VENEER LUMBER MANUFACTURER NEW ON CENTER PLATE REFERENCE REIfJFORCING SCHEDULE STEEL TRIMMER THROUGH BOLT TONGUE&GROOVE TOP OF TOP OF FOOTING TOP OF WALL TRANSVERSE TREATED TUBE STEEL TYPICAL VERTICAL VERIFY IN FIELD WATERPROOF WITH ��/����: �� � ' � �� tz _ � ��' , �" � r� :, ���� p � � � o � � 4�� tj � ���� ���� � N � � N � X Op m U OZ ao Q Ll� U LLJ � � LLJ z 0 W � z Q c J W � w � O � � ch 1� M � O� � � rnrn 00 � ti rnrn 2 x aLL J Q � O Q � > � w W w � � U Ow OC 2 U � � � . m J o � �' m r c 0 � � � � L.L � > � � � Z � w w Z � Z PROJECT : 0210-12 DRAWN BY : JPL REVIEWED BY: JPL D A T E : PERMIT 11.27.12 REVISIONS ; GENERAL NOTES S1 � � � E-TOW=8406'-0 (E)-TOF = 8400'-11 1/8 I I TOW=VIF TOF = 8402'-9 1/8 ± DOWEL NEW 8"SLAB TO EXSTG. CONC.WALL W/#5 DWLS.x 1'_8" DRIVEN INTO 5/8"fd x 4"HOLES @ 12"O.C.,TYP. 8402'-9 1/8" ± (N)-TO SLAB INDICATES NEW— 8"SLAB W/#5's EA. WAY @ 12"O.C. 8401'-0 5�/8 � (E)-TO SLAB Y (N)-TOW = TO BOT. OF (E)-FTG. ( (N)-TOF = 8402'-9 1/8 ± (N)-TOW=8402'-9 1/8 ± (N)-TOF = 8402'-0 � SAW CUT EXISTING CONC.WALL DOWN I c� (I E-TOW=8404'-2 7/8 � (E)-TOF = 8397'-5 1/8 -TOW=8406'-0 -TOF = 8400'-11 1 E-TOW =8406'-0 (E)-TOF = 8397'-5 1/8 — � — — E-TOW=8401'-5 1/8 (E)-TOF = 8397'-5 1/8 8406'-0 (E)-TO SLAB (VIF) 3 S3 1 S3 � � — � > +I �N � � � (E)-FTG. STEP ��� ��� � �— 2 S3 SAW CUT(E)-SLAB BACK DOWEL NEW WALL TO EXSTG. W/#5 DWLS.x 1'-6"DRIVEN INTO 5/8"�d x 4"HOLES @ 12"ALONG VERT. LENGTH OF WALL (THREE MIN.),TYP. DOWEL NEW 8"SLAB TO EXSTG. CONC.WALL W/#5 DWLS.x 1'_8"DRIVEN INTO � 5/8"Q x 4"HOLES @ 12"O.C.,TYP. � — � � _ � (E)-FTG. E-TOW=8406'-0 STEP (E)-TOF = 8402'-0 ��� ��� 8406'-0 (E)-TO SLAB � � � E-TOW=8414'-11 5/8 n (E)-TOF = 8402'-0 I I E-TOW=8405'-4 E -TOW=8406'-0 (E)-TOF = 8402'-0 (E)-TOF = 8402'-0 — — � — — — � � — — — � � � — — — E-TOW =8405'-4 (E)-TOF = 8402'-0 ��� VERIFY ALL DIM. W/ EXSTG. ��—� CONDITIONS & ARCH. PLANS F O U N DAT I O N P LA N SCALE: 1/4�� - ,�-o PLAN NOTES: 1. NEW CONCRETE WALLS ARE 8"THICK UNLESS NOTED OTHERWISE. 2. CONTACT ENGINEER IF OVER-EXCAVATION IS REQUIRED TO FIND ADEQUATE SOIL BEARING. 3. (E)- EXISTING FOUNDATION INDICATED AS THUS ( -- --) (N)-NEW FOUNDATION INDICATED AS THUS: ( 4. STEPS IN TOP OF FOUNDATION WALL ARE INDICATED: � 5. CONTRACTOR SHALL FOLLOW ALL RECOMMENDATIONS AND REQUIREMENTS PER SOILS REPORT. 6. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. ) TOW=8406'-0 TOF = 8402'-0 ��i(���� �— �f��F ���F ,f� .U� � L j A^, �l/ �r.f, ____ � _ - _ �� N �, � '��; 1:z' e� � � N N � X 00 m � U OZ d0 Q c O � � M r c� � � rnrn 00 rnrn _ � d � � c 0 � c� z � w w z c� z J w � O z �" °C o o � w � J w W J � � ujU > � � � L.L O W � = 0 w � U � > � � m � z ~ Q � ° 0 � m r PROJECT: 0210-12 DRAWN BY : JPL REVIEWED BY : JPL D A T E : PERMIT 11.27.12 REVISIONS ; FOUNDATION PLAN S2 0 � � J U � (2)-#5 CONT. F $��c �— 1/2"EXPANSION MATERIAL RISE&RUN ON FIRST STEP PER ARCH. (1)-#4 CONT. #5 DWLS.x CO 1'-10" �, a @ 12"O.C. T a (THREE MIN.) a PROPOSED OVERFRAMED `�� STAIRS NOT SHOWN FOR CLARITY � _ #5 DWLS.x � @ 16"O.C. � 6° PER PLAN (N)-TO SLAB INDICATES NEW — 8"SLAB W/#5's EA. WAY @ 12"O.C. a. r.. d '... �_. .: a . . a a_ a . . •– / „ aa • � ��� a a � /--- (E)-SLAB TO BE SAW CUT / (2)-#5 CONT. PER PLAN a (E)-TO SLAB � I � #5 DWLS.x 6"� @ 12"O.C. 1 p�� (THREE MIN.) CONT. #5 @ MID. HT. (2)-#5's CONT. TOP&BOT. = 1'-0 NALL .L TO DWLS INTO (E)-INTERIOR BRG.WALL PROPOSED OVERFRAMED STAIRS �` � �—c> � �-r� Ia b. a � I � I DOWEL NEW "SLAB TO ' a a I EXSTG. CONC.WALL W/#5 t . DWLS.x1'-8"DRIVEN INTO � 5/8"Pl x 4"HOLES,TYP. I a INDICATES NEW (E)-CONC. FND.WALL � . ° 8"SLAB W/#5's EA. ° WAY @ 12"O.C. PER PLAN °° a aa - (N)-TO SLAB I a � a� ° a I I I I I I I I i�i�i�i i�i i i (E)-CONC SLAB � a� (E)-CONC. FTG. v PER PLAN � d � 0 TO SLAB ° � ° PER PLAN a ° (E)-TOF l° —° _g�J ` ����.�=- A ��, �� `� �,�_ � � o � N V' C� N � X 00 Op m U OZ � O > Q L o r� O i� �— M I� c7 � � rnrn 00 rn rn 2 � a � � c 0 � C� Z � W W Z � Z J � W � O z ~ � o Q U � � Ww � W W � � Q pC � cn U > O w 0 W Q � � v � � W � � m � Q � O � � m r PROJECT: 0210-12 DRAWN BY: JPL REVIEWED BY: JPL D A T E : PERMIT 11.27.12 REVISIONS : DETAILS S3