HomeMy WebLinkAboutB13-0055 PLANS.pdf GENERAL NOTES- B13 - 0055
1- Verify Carbon Monoxide Detector installed
2- Asbestos Test- Result Negative , .=,,W.-,
.
3- Verify All Elec/ Mech meets current code All Windows on this Level to be Replaced in the Spring
4- At least 50% of new lighting to be high efficency ----------------------------------
--------------------------------
5- Fire Sprinkler System to Remain- heads to be -
adjusted as required on fire specfic application
O
% E
Q
LOWER LEVEL NOTES-
1- All work on this level is to take O
place in the Spring
2- Existing windows to be
replaced in Spring, Windows to \ /
be replaced with same size, color /
and style of windows
3- All Bedrooms to recieve new -
carpet, painting, doors and trim
work. Existing closets and closet \
doors to remain I (�
Bedroom 2
4- All Bathrooms to receive new i
Bedroom 1 t Bedroom 3
tile, plumbing fixtures, shower
enclosures, vanities, mirrors,
painting, doors and trim work } ,
O
ELECTRICAL NOTES-
1- Add 5 recessed can lights to Q
Bedroom 1
Bath 2
2- Add 4 recessed can lights to \ � /
Bedroom 2
3- Add 5 recessed can lights to —� \ O _ - O
1 0
Bedroom 3
4- All Bathrooms to receive new
light fixtures, including new 0
waterproof can light at tub/ Bath 1
and bath exhaust fans Entry Date-
shower 3-12-13
Bath 3
C)
0 -
r Existing Recessed Can Light
Drawn By-
8) Proposed Additional Recessed Can Lights WMK
Proposed Lower Level Floor Plan/ Remodel Notes
Scale 1/4"= 1' Al
GENERAL NOTES-
1- Verify Carbon Monoxide Detector installed
2- Asbestos Test- Result Negative
3- Verify All Elec/ Mech meets current code Deck Sliding Door and Window
4- At least 50% of new lighting to be high efficency Existing Windows to be replaced in Fall are new and will remain
5- Fire Sprinkler System to Remain- heads to be
adjusted as required on fire specfic application
O
E
Deck Unit P Deck
MAIN LEVEL NOTES-
1- Existing windows to be u m O 0
replaced in Fall, Windows to be " C:
replaced with same size, color
and style of windows
2- Gypsum Drywall patching and
repairs and trim work as required },
3- All finishes were updated in
2012, no additional work on this
g o Kitchen �0�
level of the unit 0
Dining Room 000 Q
L
0
Living Room z
Vaulted Ceiling
Flat Ceiling—
VJ
Entry 0
Powder
Room C:Room n
Date-
3-12-13
W/D 0
Drawn By-
WMK
Proposed Main Level Floor Plan/ Remodel Notes
Scale 1/4"= 1' A2
GENERAL NOTES-
1- Verify Carbon Monoxide Detector installed "S,
2- Asbestos Test- Result Negative
3- Verify All Elec/ Mech meets current code _
4- At least 50% of new lighting to be high efficency
5- Fire Sprinkler System to Remain- heads to be Windows to be eplaced this Fall -0
adjusted as required on fire specfic application 0
E
0
ry
0
UPPER LEVEL NOTES-
1- All work on this level is to take 0
place in the Fall �
2- Existing windows to be Trapezoid Windows 0
replaced in Fall, Windows to be
replaced with same size, color
and style of windows, interior },
glazing at office looking to main Open to Main Level of Unit / s--
level to remain
3- Bedroom and Office to recieve J
Q
new carpet, painting, doors and \ Q
trim work. Existing closets and 0
closet doors to remain Interior Windows/ Glazing to Remain },
4- Bathroom to receive new tile, Master Bedroom L 0
plumbing fixtures, shower I 0
enclosures, vanities, mirrors, Master _
painting, doors and trim work
Closet 0
ELECTRICAL NOTES-
1- Add 2 recessed can lights to 0
Master Bedroom .-
2- Add 6 recessed can lights to
Office Office
3- Bathrooms to receive new light Entry Master Date-
fixtures including new waterproof / Bath 3-12-13
can light over tub/ shower and
bath exhaust fans
j Drawn By-
Existing Recessed Can Light Draw
WMK
Proposed Additional Recessed Can Lights
Proposed Upper Level Floor Plan/ Remodel Notes
Scale 1/4"= 1' A�