Loading...
HomeMy WebLinkAboutDRB130077 Plans ApprovedDepartment of Community Development 75 South Frontage Road TOWN OF VAIL RECEIVED TelVail, CO 81657 : 970 - 479 -2128 By David Rhoades at 10:49 am, Mar 25, 2013 www.vailgov.com Development Review Coordinator Application for Design Review Additions - Residential or Commercial General Information: This application is required for all proposals involving the addition of any floor area, in- cluding net floor area and /or gross residential floor area (GRFA). This also includes proposals for `residential 250 additions' and 'interior conversions'. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information — Town Code Online. All projects requiring design review must re- ceive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and /or the Plan- ning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Fee: $300 Single Family Duplex _ Multi- Family Commercial Description of the Request: Extend the unit into the mechanical space Addition of 109 sq ft of GRFA (Residential) or sq ft of net floor area (Commercial/ Office) Physical Address: 278 Hanson Ranch Rd #403 Vail, Co 81657 Parcel Number: 2101- 082 -69 -039 Property Owner: Mailing Address: Owner's Signatu Bridge Street Investments, LLC Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) 2121 N Frontage Rd W #263 Vail, Co 81657 Phone: 970- 390 -1068 Primary Contact/ OwnerJKepresentati ryan Johnson Mailing Address: PO Box 8530 Avon, CO 81620 E -Mail: bryan @contractone.com For Office Use Only: Cash CC: Visa / MC Last 4 CC # Fee Paid: Meeting Date: Planner: Fax: Phone: 970- 390 -1068 970 - 748 -1139 Exp. Date: Auth # Check # Received From: DRB No.: DRB 13 0 0 7 7 Project No: PRJ13 -0036 Land Use: Subdivision: VAIL VILLAGE FILING 1 *BRIDGE STREET LODGE* From: 9704760081 Page: 1/2 Date: 3/18/2013 2:31:59 PM March 15, 2013 Bridge Street Lodge Condominiums ,Association, Inc. 356 E Hanson Ranch road Vail, CO 81657 JHOA Approval Attention: Board of Directors Ile, Letter of Intent to Proceed With Permitting Process Dear Board of Directors: This Letter of Intent is made this day of March, 2013, by and between ContractOne, Inc., a Colorado corporation ( "ContractOne ") and Bridge Street .Lodge Condominium Association, Inc., a Colorado non - profit corporation ("BSLCA"). This letter sets forth our understanding concerning a proposal (this "Proposal ") to which BSLCA gives its permission to ContractOne to proceed with the Town of Vail Design Review Board and building permitting process. 1. Negotiations and Transaction. ContractOne and BSLCA have had ongoing negotiations regarding a ContractOne client purchasing a portion of the common elements and making construction changes thereto. The work involved includes, but is not limited to, amending BSLCA's governing documents, drafting appropriate purchase agreements, escrow arrangernents and the like. As part of the process, ContractOne is required to pull building permits and go through the Design review Board process with the Town of Vail. This process takes time, and with deadlines approaching, the process needs to begin immediately. 2. The A egr ement. A final agreement between the parties regarding the above transaction has not yet been reached, although each party believes an agreement will be reached shortly. At this point, the parties agree that ContractOne will not start the purchase and construction of the common elements until a final, binding agreement has been reached between the parties. 3. Permitting Process. Notwithstanding the above, the parties hereby agree, and BSLCA hereyby gives its permission for ContractOne to take all necessary action to begin the building permit process and Design Review Board process with the Town of Vail and/or any other governmental or proprietary agency having such authority. 4. Costs and Expenses. ContractOne shall be solely responsible for the legal, accounting, governmental, and other fees and expenses incurred in connection with the Design Review Board process and building permit process, whether or not a final agreement between the parties is consummated. Additionally, if a final agreement between the parties is not reached, the building permit and/or the Design Review Board approval shall be voided. 5. Commercially Reasonable Efforts. The parties will negotiate in good faith and use their Page 1 of 2 From: 9704760081 Page. 212 Date: 3/18/2013 2:31.59 PM commercially reasonable efforts to docurnent and complete the transactions contemplated by this Proposal as soon as reasonably possible, subject to all of the other terms and conditions of this Proposal. 6. Nonbading Agreement. This letter merely summarizes the present intention of the parties with respect to the Proposal, and except for the obligations set forth in sections 3, 4, and S of this letter and the provisions of this section 6, which will be legally binding in accordance with their terms, this letter will not create legally binding rights or obligations in any respect, either expressed or implied, in favor of any party, and each party agrees not to contend to the contrary unless and until the final agreement has been executed and delivered. Please acknowledge your agreement to the Proposal by signing where indicated below. This letter may be signed in counterparts and delivered by facsimile or e-mail transmission, all of which counterparts together will constitute one agreement and Each of which will constitute an original copy. This letter will become effective upon execution by both of the parties. CONTIRACTONE, INC. BRIDGE STREET LODGE CONDOMINIUM ASSOCIATION, INC. ahn on—a s President Signature D e Name and Title LJ Date Page 2 of 2 Property Information Property Address 278 Hanson Ranch Rd #403 Vail, CO Parcel # 2101- 082 -69 -039 Legal Description Bridgestreet Lodge Unit #403 Development Site Area sq ft Primary sq ft acres 3,313 buildable sq ft Secondary sq ft Zone District / SDD # Hazard Zones Sections 12 -21 & 14 -7 SnowAvolanche ..., High Severity Moderate Severity � 'IN /A Debris Flow F_ High Flow �! Moderate Flow High Avalanche [µ� N/A Rock fall r High Severity ["'-Medium Severity ["" N/A Excessive Slopes 3 ' >_30% N/A Flood lain p ..� Y p Y �.. - 100 year flood lain Floodwa Wetlands N/A Creeks, Streams Section 12 -14 -17 Gore Creek F on site r adjacent to site F N/A Other tributary: on site adjacent to site "" N/A Proiect Information Project Description Interior remodel and expansion of sqft (SQFT Calcs include 402 & 403) Development Standards Allowed Existing Proposed Gross Residential Floor Area (maximum) Chapter 12 -15 Primary sq ft 3,313 3,422 Secondary sq ft EHU sq ft TOTAL sq ft 250 Addition "" °; Interior Conversion Credits: Setbacks (minimum) Section 14 -10 -4 Front ft Side ft Side ft Rear ft Watercourse ft Site Coverage (maximum) see definition Section 12 -2 -2 Building Height (maximum) see definition Section 12 -2 -2 Sloping ft Flat ft Landscaping See definition Section 14 -2 -1 Section 14 -10 -8 Softscape sq ft Hardscape sq ft TOTAL sq ft Driveway Sections 14 -3 -1 & 14 -3 -2 Max Curb -cuts Max Grade @ cen- terline Min Width Heated drive? Yes —No µ!Yes ? !No Snow Storage % Parking Sections 12 -10 & 14 -5 #Enclosed Spaces #Unenclosed TOTAL Outdoor Lighting (maximum) Section 14 -10 -7 # fixtures M I io N r N I W N° or I i,i Z N L'S J ti C) — J co H co z I � � I I I I . I� O O1 N W� I� 0 ho (D J O C� U O Ih / W d O s` U - H W h _ _ 0 J �� U W Q �� a 09 W Z Z U Q Uw LLj 777 y'9 J/ Only Unit 403 a part of this request Y M U O W O F W Z U � J o 0 N C5 o n N r N 0 O 0 F O W U J o Z'l o ,0 ro 9'Ol " m o ,0'll Z'L <r ,09 ,L'Sl L'9 Ocl � U L�1 Z C) = W B� . I io N r N I W N° or I i,i Z N L'S J ti C) — J co H co z I � � I I I I . I� O O1 N W� I� 0 ho (D J O C� U O Ih / W d O s` U - H W h _ _ 0 J �� U W Q �� a 09 W Z Z U Q Uw LLj 777 y'9 J/ Only Unit 403 a part of this request Y M U O W O F W Z U � J ��`�s � ��. REMO REL CA 11 0, TOWN OF VAIi. '2 SECTION A2.1 1 /4 " =1' -0" BATHROOM 1 UNIT 403 PROPOSED FLOOR PLAN GENERAL NOTES 1. FOR ADDITIONAL ELECTRICAL /LIGHTING INFORMATION, SEE ELECTRICAL ENGINEERING DRAWINGS (BY OTHERS). 2. ALL LIGHTING, ELECTRICAL AND FIRE PROTECTION WILL BE BROUGHT UP TO CURRENT CODES. 3. NEW INTERIOR WALLS TO BE 3 -5/8" METAL STUDS WITH 5/8" TYPE "X" DRYWALL ON EACH SIDE WITH SOUND ATTENUATION BATT INSULATION 4. PROPOSED ADDITIONAL SQUARE FOOTAGE 112 SF 5. EXISTING GRFA: 1843 SF 6. PROPOSED TOTAL SF: 1955 SF oC) 0 c� Am-j� (f) stud iospin nato.com P. 970.390.5836 W o t7 p �a 0 oc CO J o C) � J W o Lu H J W > �a m W This document and the ideas and designs incorporated herin, as an instrument of professional service, is the property of Studio Spinnato, and is not to be used in whole or in part for any other project without the written authorization of Studio Spinnato, Inc. JOB #: 1206.2 DRB SUBMITTAL 031413 A2.1 Mechanical Specifications 1. Immediately notify the Engineer of any discrepancies. 2. It shall be assumed that all subcontractors are experienced and thoroughly knowledgeable in their respective areas of the construction industry and shall perform in a responsible manner in an appropriate construction sequence. 3. Do not scale drawings. Verify dimensions in field prior to commencement of work. 4. It is the intent of these drawings and specifications to establish a standard of quality. The Engineer reserves the right to take exceptions to approve methods and materials not reflected herein. 5. Failure to order, or release order, for materials and /or equipment will not be accepted as a reason to substitute alternate materials, equipment, or installation methods. 6. Work shall be performed in a workmanlike manner to the satisfaction of the Architect & the Engineer. 7. Labor, materials, and equipment shall conform to the latest applicable editions of local, State of Colorado, and National Codes and ordinances. If conflict between those publications exists, the most stringent requirement shall apply. 8. The drawings show the intent of the mechanical systems but do not show all details required. It is the responsibility of the Contractors to install complete & operable systems, which conform to the manufacturers' installations instructions & industry standards. 9. Systems shall be tested for proper operation. If tests show work is defective, Contractor shall make corrections necessary at no cost to Owner. 10. It is the Contractors' and manufacturers' responsibility to assure themselves that the code authorities will approve any product to be installed on the project. 11. Provide 4" high level concrete equipment pads beneath gas fired, floor mounted mechanical equipment in mechanical room. 12. Offset piping, ductwork, etc. as necessary to accommodate structure, beams, columns, and existing equipment. Remodel. Demolition & Unforeseen Conditions 13. Provide mechanical demolition required. Visit site prior to bid to determine extent of work involved. Provide labor and materials as required to maintain and /or restore continuity of service to existing systems, whether indicated or not. 14. Be responsible to field verify existing equipment or ductwork remaining to be reconnected to new or existing systems. Provide ductwork, piping, controls, diffusers, etc., as required to restore continuity to system(s). 15. All new ductwork, piping, equipment, etc. is shown with dark lineweight. All existing ductwork, piping, equipment, etc. is shown with light lineweight. 16. All removed piping, ductwork, equipment, etc. are to be disposed of by Contractor unless noted otherwise. 17. All existing support rods and straps now supporting ducts, pipes, electrical conduit, etc. that are removed to allow room for installation of new equipment shall be relocated and reinstalled, or replaced if damaged. 18. Extend and modify existing fire protection systems to new and remodeled areas. 19. Insulate all new domestic hot water and domestic hot water recirculation with U.L. approved, white, all service, glass fiber, snap -on, pipe insulation. 1 -1/2" thick on piping <15' in diameter and 2" thick on piping >15'. Insulate fittings with glass fiber blanket insulation and premolded PVC covers. Provide deduct alternate price to insulate with Armaflex. 20. Insulation for all types of piping shall be carried full size through pipe hangers or pipes shall be supported with vibration clamps. 21. Internally line all new ductwork inside the thermal envelope with the same thickness of insulation as is on the duct it is connecting to. Insulation shall be U.L. rated, glass fiber insulation with a continuous vapor barrier. Piping 22. Domestic Hot, Cold & Recirculation piping inside building - Type 'L' copper water tube, wrought copper fittings and no lead solder. 23. Waste & Vent piping inside building: Waste lines above ground - Standard weight, C.I. soil pipe, and fittings, or hubless, C.I. soil pipe and fittings. Up through 2 -1/2" may be standard weight, galvanized steel pipe with black, C.I. drainage fittings. Vent lines - Schedule 40 ABS -DWV plastic pipe and fittings (ASTM D2661) or Schedule 40 PVC -DWV plastic pipe and fittings (ASTM D2665). All pipe and fittings shall bear NFS -DWV mark and shall be joined with solvent weld joints as recommended by the manufacturer. 24. Gas Piping - Schedule 40 black steel pipe, 150 lb. malleable iron screwed fittings on above ground pipe, welded fittings with all piping coated and wrapped on buried pipe. Welded gas piping shall be pressure tested at a minimum of 60 psi per Town of Vail amendment to the 2009 IFGC, section 406.4.1. CSST pipe is prohibited entirely. 25. Gas Valves - Lubricated plug valve 175 lb. W.O.G. iron screwed or flanged. 26. Copper pipe Valves and Specialties: Gate Valves: Bronze, Class 125, 200 lb. W.O.G. Ball Valves: Bronze, Class 125, 200 lb. W.O.G. Check Valves: Bronze, Class 125, 200 lb. W.O.G. Balancing Valves: 125 psig w.p. for 250F service tight shut -off, Illinois dual - purpose, balancing /shut -off valve, Hoffman, Sarco, or equivalent. 27. Support pipe with rod and clevis or clamps. No pipe tape allowed. 28. Dielectric Unions - Furnish and install a dielectric union at all connections where non - ferrous material is in contact with ferrous material and fluid in not protected with corrosion inhibitors. 29. Boiler flue shall be Type B gas vent, complying with UL -441. Ductwork 30. Duct sizes shown on drawings are outside (sheet metal) duct dimensions. 31. All ductwork shall be sealed airtight with duct mastic. Duct tape is prohibited. 32. Provide 1/4" galvanized mesh screen on all combustion air ducts or openings. 33. Ducts and piping penetrating through roof shall have roof flashing with caulk type counter flashing sleeve or by method acceptable by roofing manufacturer. Installation shall be watertight. 34. Provide turning vanes in all mitered rectangular elbows. 35. All ducts shall be 26 gauge minimum. Duct gauge and construction shall conform to SMACNA HVAC Duct Construction Standards. Sequence of Operation 1. Domestic Water Heating a. Upon a call for domestic water heating from aquastat A -1 set at 140 °F (adj), existing pump (E) P -1 shall start, and existing boiler (E) B -1 shall be enabled. b. Thermostatic mixing valve TMV -1 shall be set to maintain a discharge temperature of 120 °F (adj). O 1 z n 11/4 11 , DHW TO UNITS 11/2 21T 211 (N) TMV -1 Mr c �I H 211 N.C. DHW TO RESTAURANT (E) P -2 5=1 50ILER FIFfNG SCHE1°'fAfilC NO SCALE DHW - HR --- DOMESTIC HOT WATER RECIRCULATION FROM BUILDING DCW FROM CITY MAIN 5T0 A TAN ,5 SYM. DESCRIPTION STORAGE DOMESTIC BOILER MANUR 4 MODEL REMARKS SYM. (14) FLOWRATE FLOWRATE DESIGN GPM MANUI R . MODEL REMARKS (N) ET -1 DOMESTIC 5` 6TEM (GALS) CONDITIONS CONDITIONS I.UESSELS TTA -42 ASME RATED EQUIPMENT ENTIRELY 'I 69 HONE'I'I.UELL TEMPERATURE RANGE (N) TMV -1 DOMESTIC 3.5 GPM 100 DEG RISE 180 DEG LOCHINVAR ASME RATED, (N) 5T-1 5TORAGE TANK 400 1440 L IWUT 42 T GPM RGA0400H JACKETED JACKETED THE MO6TAT f t-11XING VAL= V 6 SYM. SERVES MINIMUM DESIGN P.D. AT MANUR 4 MODEL REMARKS (14) FLOWRATE FLOWRATE DESIGN GPM DEMO - EXISTING EQUIPMENT TO 5E DEMOLISHED (E) (N) ET -1 DOMESTIC 5` 6TEM FLOOR 141 22 I.UESSELS TTA -42 ASME RATED EQUIPMENT ENTIRELY 'I 69 HONE'I'I.UELL TEMPERATURE RANGE (N) TMV -1 DOM. HOT WATER 3.5 GPM (o 0 GPM 19.5 PSI MX 129C (1 -1/2 ") OF 90 °F To 120 °F, ASSE 1011, C3�S r ' ZLY O RECIRC CONNECTION • BASED ON ESTIMATED DEMAND FROM EXISTING 211 DHW PIPE SERVING BUILDING XPAN,5 f ON TAN ,5 SYM. SERVES MOUNTING ACCEPT. VOL. (GALS) TOTAL VOL. (GALS) MANUR 4 MODEL REMARKS (14) 45ANDON - EXISTING EQUIPMENT TO 5E 45ANDONED IN PLACE (D) DEMO - EXISTING EQUIPMENT TO 5E DEMOLISHED (E) (N) ET -1 DOMESTIC 5` 6TEM FLOOR 141 22 I.UESSELS TTA -42 ASME RATED EQUALS: TACO, AMTROL. 0MI Ln N N MDD L LEGEND TAG LA DESIGNATION O (14) 45ANDON - EXISTING EQUIPMENT TO 5E 45ANDONED IN PLACE (D) DEMO - EXISTING EQUIPMENT TO 5E DEMOLISHED (E) EXISTING - EXISTING EQUIPMENT TO REMAIN (R) RELOCATE - EXISTING EQUIPMENT TO 5E RELOCATED (N) NEW - NEW EQUIPMENT ENTIRELY 0MI Ln N N W N W ii LA O 0 U � � W 11.L LU WUJZ O Lo Ca 'I 69 (P seal C3�S r ' ZLY O A Z A O O U �o xA F=q U O 04 O � Z O U A 00 10=0 N Issued For No. Date Comment 1 2/15/13 COORDINATION 2 2/22/13 PERMIT MECHANICAL SCHEDULES, SCHEMATICS, AND SPECIFICATIONS Project No. Sca le: 12032.00 N/A Drawn By: Checked By: JAN JDR M1,80 W W Z Z w w O u- O Lu N N z w O D w N O ff Zw N Z fQ O N � O 0- O fQ d) 0 W U p �ly oW w � M � O mZ d f� p 0 Iz U_D Z Qo OZ f� u_ wZ w� Z OL W N Z � LU 1— O d w� w K zw �7 0- Luff w 0- z ly �w O � p }z 4 0- q (X L � O � U O 0 � O z qw Ww ��z o ' Z U_ -1w 0wz f d X w w LU O u p ? 4 O ff Ci ji 0 Q w N Uzi Z Z ff q w �__ =ff0_ Uw0 you B (D-- (AD 0 (D-- DEMO WALL. NEW WALL. 2 (o/2(o 2ro /2ro ACCE 55 51R I APE. ( R) 1"L4U 11 17�i1 zT �� ST -3 OR 8 '<P E301LE R FLUE AND CA fIf=. (Try OF 4) WATER TREATMENT QU I f=MNT. (R) RELOCATE 5 -2 COM5U6T I ON AIR DUCT_ LOCATE DHW AND — DCW L INE5 IN WALL A5 NECE554R"�, d s 0♦ ° (E) ( IGA B -3 /\ K(E) • ° .. GHN0300 ro"O EXH GFNOIB0 GFNm(o� t �D� I � ♦ I I° III ST -2 d L i 4A EXISTING; MECI�4NICAL R00M FLAN ACCESS R I DBE. (R) RELOCATE ACC 55 45 WATER TREATMENT EQUIRMENT. (R) DE110 CONCRETE PAD UNDER 5 -142 50ILERS. 9 RELOCATE 5 -1 FLUE AND CO -15U &T I ON A f R DUCT, CDJ 1�1 ST -1 I\ (D) �I I-- _/ 1 1011 C ELECTRICAL f=ANEL. (R) WATER THE AT1 IENT E QU I RMENT. ( R) RELOCATE 5RRIN LER AND SAS L IN & IN WALL A5 N C ,55AR�T. RE ,5TOR 5EFAf;P ATEL� METERED GAS LINES TO CORRESROND ING OILER 5� &TEM5. RELOCATE ELECTRICAL RANEL TO HALLWAA�. NO s° �E) /0- A. A NEW LOADS ANTICIRAT D. 5 -3 GTR � REQUIRED FOR NEW ♦ ♦ d ' • d A EQUIRMENT GHN0300 (N ET41 ET E) ro "O EXH 1=D R) 310/1 0 (N) 2 FLOOR DRA IN. EXTEND I G1 =N���� W,45TE $ VENT TO NEW GFN0& 0I LOCATION. INCLUDE 5_2 '. . 8 -1 TRAP= U,�RD ,5. (T�tf=) CRS CR) O 5T _3 •d d I 5T-1 II II I d • , C NEW CONCRETE 1=AD UNDER 5OILER6. FfROFOSEED 1 IRCO1l FLAN ROUTE 5=142 5OILR FLUE& AND CA R I RE,5 THROUGH ROOF. TERMINATE WITH ACDAFT/�fVENT I VE TARE ROOF C ,4R. UD omI Lin N N u.l N W ii LA 0 O 0 Wi z ., .SOX o -411 W 11..L LLI X \P Sea I O A Z A O 0 U �o xA H U W O O � Z O u W x A 00 M--� N Issued l=or No. Date Comment 1 2/15/13 COORDINATION 2 2/22/13 PERMIT MECHANICAL ROOM PLAN NORTH Project No. Sca le: 12032.00 3/8" = 1' -0" Drawn By: Checked 5y: JAN JDR M2.0 W W z z w Lu 0 0 OL z Lu 0 0 W 0 Lu �ff zW _ o� m0 0 o (Y �OL 0 m u °o o W W m �o Z � � =� I--Z u-D Z� Qo I� oz (� WzI W� z� Wd) Lu � .'0 o w� LU LU� zw 0 0- Luffw = fY u1 m3: 0 Q O_ OL 0 Lu o �o �u z dw O � w ��z Q z LL -1 w 0��? �j d X w Lu Lu ono � ? 4 o�(Y �Ze Q W N Wzi zz(Y- -q W)- _ffOL uLuo Cl z�o