HomeMy WebLinkAboutB12-0309 REV 20 PLANS APPROVED 0 � N � � � MDP EM PANEL MECH PANEL .� � PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL � � � � � PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W � V (6 O � MOUNTING: SURFACE MAINS: 600A MLO MOUNTING: SURFACE MAINS: 100A MLO MOUNTING: SURFACE MAINS: 200A MLO � �L � U Op TYPE: AIC: 10K TYPE: AIC: 10K TYPE: AIC: 10K � •� pp PHASE PHASE PHASE PHASE PHASE PHASE � � � C�' DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION O �p � O EM PANEL 11176 100 3 1 2 3 200 11573 DORM A& B PANELS BOILER 500 20 1 1 2 1 20 1200 GARAGE 'RED' LIGHTING CH-1 2750 40 2 1 2 1 20 500 B-2 U � � � � 11176 3 4 11573 P-1 46 20 2 3 4 1 20 250 UP STAIRS 'RED' LIGHTING " 2750 3 4 2 20 450 P-2 � � � � 11176 5 6 11573 46 5 6 1 20 250 UP STAIRS 'RED' LIGHTING CH-1 1200 20 3 5 6 450 � �� N � � GARAGE A& B PANELS 7460 200 3 7 8 3 100 9713 EHU A PANEL P-4 45 20 1 7 8 1 20 0 RED LIGHT PUSH BUTTONS 1200 7 8 2 20 450 P-3 •� � � � LL _ 7460 9 10 9713 SPACE 0 9 10 1 20 1000 FRIDGE 1200 9 10 450 � � � � �(� 7460 11 12 9713 OFFICE OUTLETS 360 20 1 11 12 1 20 720 GARAGE OUTLETS UH-3 500 20 2 11 12 1 20 900 P-5 � � U �O � M E C H P A N E L 1 1 7 8 0 2 0 0 3 1 3 1 4 3 1 0 0 9 5 9 0 E H U B P A N E L O F F I C E O U T L E T S 3 6 0 2 0 1 1 3 1 4 1 2 0 5 0 0 O F F I C E L I G H T S " 5 0 0 1 3 1 4 2 2 0 4 5 0 P-6 � Q N � U 11780 15 16 9590 OFFICE OUTLETS 540 20 1 15 16 1 20 500 AIR FILL STATION UH-3 500 20 2 15 16 450 " '� � � oLS QO � " 11780 17 18 9590 " OFFICE OUTLETS 900 20 1 17 18 2 80 5700 AIR COMPRESSOR " 500 17 18 2 20 450 P-7 � Q � 00 SPACE 0 19 20 3 100 0 IVSS MECH OUTLETS 360 20 1 19 20 5700 " EF-2 50 20 1 19 20 450 " � •� W �� ?> SPACE 0 21 22 0 UH-1 375 20 2 21 22 1 20 750 TRUCK POWER RV-1 0 2 2 22 1 20 150 GF-1,2,3 w U � = 0 � SPACE 0 23 24 0 " " 375 23 24 1 20 750 TRUCK POWER � FC-4 250 20 1 23 4 2 20 1000 UH-2 � f� SPACE 0 25 26 0 SPACE LOWER LVL IT RM 500 20 1 25 26 1 20 750 GARAGE DOOR 26 1000 � W � � � � SPACE 0 27 28 0 SPACE LOWER LVL IT RM 500 20 1 27 28 1 20 750 GARAGE DOOR HEAT TRACE (30mA GFI) 1750 30 2 27 28 2 20 375 UH-1 � � � � � SPACE 0 29 30 0 SPACE GARAGE RADIANT 750 20 1 29 30 1 20 750 GARAGE DOOR " 1750 29 30 375 " '�'' U N O � SPACE 0 31 32 0 SPACE PHONE 250 20 1 31 32 2 30 750 IT EQUIPMENT HEAT TRACE (30mA GFI) 1750 30 2 31 32 2 20 375 UH-1 U � 'V p � SPACE 0 33 34 0 SPACE UPSTAIRS LIGHTS 500 20 1 33 34 750 " " 1750 33 34 375 " � � � � � SPACE 0 35 36 0 SPACE GARAGE LIGHTS 1500 20 1 35 36 1 20 500 ITANTENNA HEATTRACE (30mA GFI) 1750 30 2 35 36 2 20 375 UH-1 � � � � � SPACE 0 37 38 0 SPACE BLOCK HEATER 500 20 1 37 38 3 20 850 ENGINE EXHAUST " 1750 37 38 375 " (� � Q � � SPACE 0 39 40 0 SPACE GENERATORANNUNCIATOR 500 20 1 39 40 850 HEATTRACE (30mA GFI) 1750 30 2 39 40 1 20 250 FC-1 � 00 SPACE 0 41 42 0 SPACE GEN. BATT. CHARGER 500 20 1 41 42 850 1750 41 42 1 20 250 FC-5 Q X O m LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY O � CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: 0.94 _ 0.91 0.85 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS ;.1„�7='rr�`�,,,fk LIGHTING 20111 56 20111 56 LIGHTING 4200 12 4200 12 LIGHTING 0 0 0 0 ��`j +°` ffl� {f � RECEPTACLES 50040 139 30020 83 RECEPTACLES 9990 28 9990 28 RECEPTACLES 0 0 0 0 �`k���`�I[j ,y ,Z� � �`F MECHANICAL 62227 172 � 71062 197 MECHANICAL 18337 51 � � 21187 59 MECHANICAL 35340 98 36715 102 ti�.:'��` _ � �, = KITCHEN 51500 143 33475 93 KITCHEN 1000 3 650 2 KITCHEN 0 0 0 0 � `� � �" -- TOTAL 183878 509 154668 428 TOTAL 33527 93 36027 100 TOTAL 35340 98 36715 102 -�� � �`` �' ' ' _ ,*,•. -=�" �. ,�7 �:, :;} : ! ~*.4' rf Y�, t`r � �:l � t�. �1r;�1�'`�7�1JAut�r.` ,, � 1��'r�+,i7711[TYLYI�L VOLTAGE DROP CALCULATIONS VAIL FIRE STATION #2 VD= 2*(Lenqth)*(Resistance/kFT)*(Current) Demand Load Calculations (Sets of Cond's)*(1000) (Per NEC Article 220 Parts I-III) ■ XFMR to CT - 3 Sets #400 MCM AI � � Initial Voltage(V): 208 Quantity Volt-Amps Demand Total (VA) Current(A): 600 Liqhtinq � Length(ft): 80 Fire Station Li htin IECC 2009 6422 SF X 1 .00 X 100% = 6422 � Sets of Conductors: 3 g g � � Receptacles z Resistance(Ohms/kFT): 0.059 Commercial Areas Rec 6422 SF X 1 .0 = 6422 VA Voltage Drop(V): 1.64 IT Equipment/Computers 15 EA X 1500.0 = 22500 z Voltage(V): 206.36 Radio Equipment 5 EA X 1200.0 = 6000 O %VD: 0.79% Truck Connections 3 EA X 1500.0 = 4500 O O CT to MDP -3 Sets #250 MCM AI Receptacle Total 1 LS X 34922 VA � ~ Initial Voltage(V): 206.36 1 st 10 kVA Receptacle Load at 100% 1 LS X 10000 X 100% = 10000 Q � >10 kVA Recet acle Load at 50% 1 LS X 24922 X 50% = 12461 Q � � Current(A): 600 P � � Length(ft): 90 Kitchen Equipment � � � G E N E RATO R E G-1 : Sets of Conductors: 3 Range 3 EA X 1500 X 65% = 2925 w O Resistance(Ohms/kFT): 0.066 Microwave 3 EA X 1200 X 65% = 2340 � � PROVIDE 208V 3-PHASE 35KW DIESEL GENERATOR, CUMMINS MODEL DGBB. VOltag@ DI'Op: 2,3$ DISpOSaI 3 EA X 1500 X 65% = 2925 U PROVIDE 70 GAL SUB-BASE FUEL TANK FOR APPROXIMATELY 24 HOURS VO�ta e V : 2�3.99 Refrigerator 5 EA X 1500 X 65% = 4875 � � WORTH OF FUEL. PROVIDE 3-POLE 100A TRANSFER SWITCH AS WELL AS g � � Dishwasher 4 EA X 1500 X 65% = 3900 O J ANNUNCIATOR, BATTERY CHARGER,AND ALL REQUIRED ACCESSORIES. %VD: 'I.93% o W � Misc Appliances 8 EA X 1500 X 65/o = 7800 MDP to EM Panel- 1 Set#1/0 AI Laundry Equipment � z � � (FUTURE) Initial Voltage(V): 203.99 Washer 1 EA X 1500 X 100% = 1500 � � EM MECH GARAGE A GARAGE B DORM A DORM B EHU A EHU B Current(A): 100 Dryer 1 EA X 5�� X 100% = 500 � � PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL � E^- � 100/3 � Length(ft): 90 Electric Heatinq Equipment _ � � `� Sets of Conductors: 1 Unit Heaters 4 EA X 1500 X 100% - 6000 I Resistance(Ohms/kFT): 0.2 Elec Baseboard 16 LF X 250 X 100% = 4000 � Voltage Drop: 3.60 Mechanical Equipment � Voltage(V): 200.39 Garage Engine Exhaust 1 EA X 2000 X 100°/o = 2000 9,400 AIC 20,000 AIC 14,700 AIC 14,700 AIC 11,500 AIC 11,500 AIC %�/�: 3.66% Garage Supply Fan 1 EA X 2��� X ���% = 2��� Q PROVIDE SHORTEST RUN Garage Doors 3 EA X ���� X 100% = 3000 N ATS POSSIBLE, MINIMIZE THE Co-ray-vac Fan 1 EA X 20�0 X ���% = 20�� > NUMBER OF CONDUCTOR BENDS. Air Compressor 1 EA X 11400 X 100% = 11400 � 100/3 DO NOT INSTALL TVSS WITHIN Condensing Units 5 EA X 4��� X �0�% = 2���0 TRANSFER ELECTRICAL EQUIPMENT. FaCI COIIS 5 EA X 1500 X 1 00% = 7500 SWITCH Tvss Exhaust Fans 10 EA X 100 X 100% = 1000 (4#1 CU, 1#8CUG)3"C OR CURRENT TECHNOLOGY = (4#1/0 AL, 1#6ALG)4��c (4#2 cu, #2�)2��c #c�2oo-2os Bo eps 2 EA X 1500 X 100% = 9000 AE PR JE T : 12017 (4#3/0 CU, 1#6CUG)4��c oR Add'I 25% of Max Motor Load 1 EA X 10000 X 25% = 2500 DATE: ISSUE: (4#250MCM AL, 1#4ALG)4"C (1)SPARE 4"C 20,900 AIC 12-19-12 DRYER VENT REV. �g TOTAL 127648 12-19-12 RFC #067 � M For 208V, 3-Phase, 4 Wire Service 127648 (VA) / 361 = 354 AMPS 01-02-13 REVISION #11 11 57,400 AIC 23,000 AIC 02-06-13 ASI # 015 1� 100/3 200/3 200/3 200/3 100/3 100/3 100/3 �2�2ooa 03-07-13 ASI # 016 � c � I I I I ACES � 3[(4#400 MCM AL)4"C] � � 600/3 � � � 03-25-13 ASI # 016 REVISION 1 Drawn By: Checked By: UTI LITY CTL AEC TRANSFORMER MAIN DISTRIBUTION PANEL "MDP" PAD MOUNTED NE-LINE, LOCATE EXTERIOR, 600A 120/208V 3P 4W ADJACENT TO METER/CT. > > > 42 kAI C PANELS & LOAD CALCS ELECTRICAL ONE-LINE DIAGRAM NO SCALE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED SCALE: NONE AT ONE-LINE, NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION ACCEPTABLE, SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP Received DRAWING REVIEW. F�`��� �� y,��f M By Lynne Campbell at 3:39 pm,Apr 01, 2013 ! YY Y 1 L • 2 of 10 m COPrRIGtiT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N � � � � O -�'' � (� � � � N DORM A PANEL DORM B PANEL EHU A PANEL � � � ° � � PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT:VAIL FIRE STATION#2 ENGINEER: CTL � � •� U � PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V,3P,4W � (n � � � MOUNTING: SURFACE MAINS: 200A MLO MOUNTING: SURFACE MAINS: 100A MLO MOUNTING: RECESSED MAINS: 100A MLO � � ,� O , TYPE: AIC: 10K TYPE: AIC: 10K TYPE: AIC: 10K O ,� O Q O PHASE PHASE PHASE PHASE PHASE PHASE U Q � �� � DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION � � �� N � � KITCHEN OUTLETS 900 20 1 1 2 1 20 1000 LIVING/DININGLIGHTING BEDROOM OUTLETS 1080 20 1 1 2 1 20 500 HALL/UTILITY LIGHTING � LIVING ROOM OUTLETS 1080 20 1 1 2 1 20 500 LIGHTING � � 'p � � _ KITCHEN OUTLETS 900 20 1 3 4 0 SPACE BEDROOM OUTLETS 1080 20 1 3 4 LIVING ROOM OUTLETS 1080 20 1 3 4 1 20 500 LIGHTING '� i � � � KITCHEN OUTLETS 900 20 1 5 6 1 20 1000 MECH RM LIGHTING BEDROOM OUTLETS 1080 20 1 5 6 1 20 500 DORM LIGHTING BED OUTLETS 900 20 1 5 6 1 20 500 LIGHTING � � V O � FRIDGE 1500 20 1 7 8 0 SPACE BEDROOM OUTLETS 1080 20 1 7 8 0 SPACE BATH OUTLETS 230 20 1 7 8 1 20 500 LIGHTING � J Q N N � FRIDGE 1500 20 1 9 10 0 SPACE HALL OUTLETS 1080 20 1 9 10 0 SPACE KITCHEN OUTLETS 900 20 1 9 10 1 20 500 LIGHTING � �S � � � � MW 1500 20 1 11 12 0 SPACE UTILfTYRM OUTLETS 1080 20 1 11 12 0 SPACE KITCHEN OUTLETS 900 20 1 11 12 0 0 SPACE .� � 0 � � ('a DW 1500 20 1 13 14 0 SPACE BATH OUTLETS 410 20 1 13 14 0 SPACE FRIDGE 1500 20 1 13 14 1 20 1500 WASHER � •V W �,ct DISPOSAL 1500 20 1 15 16 0 SPACE BATH OUTLETS 410 20 1 15 16 0 SPACE MW 1500 20 1 15 16 2 30 2500 DRYER w -� W � ~ � O V E N/R A N G E 5 0 0 0 2 0 1 1 7 1 8 0 S P A C E S P A C E 0 1 7 1 8 0 S P A C E D W 1 5 0 0 2 0 1 1 7 1 8 2 5 0 0 " N � _ � � DORM LIVING RM OUTLETS 540 20 1 19 20 0 SPACE SPACE 0 19 20 0 SPACE DISP 1500 20 1 19 20 1 20 250 FC-2 � � W � � � � DORM LIVING RM OUTLETS 540 20 1 21 22 0 SPACE SPACE 0 21 22 0 SPACE OVEN/RANGE 0 40 2 21 ° 2� � DORM LIVING RM TV 1500 20 1 23 24 0 SPACE SPACE 0 23 24 0 SPACE " 0 23 24 0 SPACE '�'' U N O � DINING RM OUTLETS 540 20 1 25 26 0 SPACE SPACE 0 25 26 0 SPACE SPACE 0 25 26 0 SPACE V �� .V DO O SPACE 0 27 28 0 SPACE SPACE 0 27 28 0 SPACE SPACE 0 27 28 0 SPACE � � O � Q SPACE 0 29 30 1 20 1200 WASHER SPACE 0 29 30 0 SPACE SPACE 0 29 30 0 SPACE '— U � SPACE 0 31 32 2 30 2200 DRYER SPACE 0 31 32 0 SPACE 0 0 U � Q pp � SPACE 0 33 34 2200 SPACE 0 33 34 0 SPACE 0 0 L � � � �� � Q � SPACE 0 35 36 0 SPACE SPACE 0 35 36 0 SPACE 0 0 X SPACE 0 37 38 0 SPACE SPACE 0 37 38 0 SPACE 0 0 m SPACE 0 39 40 0 SPACE SPACE 0 39 40 0 SPACE 0 0 SPACE 0 41 42 0 SPACE SPACE 0 41 42 0 SPACE 0 0 � � LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY .11;trrrrrrr�irri, CALCULATED POWER FACTOR: PROVIDE FEED THRU LUGS TO DORM B PANEL. LOADS FROM DORM B PANEL ARE SHOWN BELOW. CALCULATED POWER FACTOR: PROVIDE FEED THRU LUGS TO DORM A PANEL. LOADS FROM THIS PANEL ARE SHOWN ON DORM A PANEL CALCULATED POWER FACTOR: {f�s�j�`„'; �-� fsl,. 0.99 1.00 0.99 ;` ��Y � ,y ,� CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS �`-y`�' '� �''1� _. LIGHTING 3500 10 3500 10 LIGHTING 1500 4 1500 4 LIGHTING 8500 24 8500 24 '`t� '� _ � � �.:: RECEPTACLES 13020 36 11510 32 RECEPTACLES 7200 20 7200 20 RECEPTACLES 5040 14 5040 14 -�• � -��:t U • �` MECHANICAL 1300 4 1600 4 MECHANICAL 100 0 112.5 0 MECHANICAL 1800 5 2175 6 �fm,' �, ��} �;� :;} .= KITCHEN 16900 47 10985 30 KITCHEN 0 0 0 0 KITCHEN 13800 38 8970 25 `: � �.' �' TOTAL 34720 96 27595 76 TOTAL 8800 24 8813 24 TOTAL 29140 81 24685 68 �� �`` � t ,c �r; �,,�: �'1t;�.r .,�]I1JA'u k:. ,,. 1��'r�+,i7711[TYLYI�L � N � � 0 Z O Z - O O � � - o � Q � � GARAGE A PANEL GARAGE B PANEL (FUTURE) EHU B PANEL Q � PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL � � PROJECT#: 12017 VOLTAGE: 120/208V,3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 � I � VOLTAGE: 120/208V, 3P,4W w O MOUNTING: SURFACE MAINS: 200A MLO MOUNTING: SURFACE MAINS: 200A MLO MOUNTING: SURFACE MAINS: 100A MLO C� > r , TYPE: AIC: 10K TYPE: AIC: 10K TYPE: AIC: 10K v PHASE PHASE PHASE PHASE PHASE PHASE � .. DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION O J W _ MENS PUBLIC BATH 430 20 1 1 2 1 20 352 EXTERIOR LIGHTING SPACE 0 1 2 0 SPACE LNING ROOM OUTLETS 1080 20 1 1 2 1 20 500 LIGHTING � � � Q WOMENS PUBLIC BATH 430 20 1 3 4 1 20 250 GARAGE LIGHTING � SPACE 0 3 4 0 SPACE LIVING ROOM OUTLETS 1080 20 1 3 4 1 20 500 LIGHTING \ AL OU L S 1 0 2 1 5 6 2 A L G I SPACE 0 5 6 0 SPACE BED OUTLETS 900 20 1 5 6 0 SPACE � � � � SPACE 0 7 0 SPACE SPACE 0 7 8 0 SPACE BATH OUTLETS 230 20 1 7 8 0 SPACE � SPACE 0 9 10 1 20 250 GARAGE LIGHTING SPACE 0 9 10 0 SPACE KITCHEN OUTLETS 900 20 1 9 10 2 40 4400 OVEN/RANGE � � � SPACE 0 11 12 1 20 250 GARAGE LIGHTING SPACE 0 11 12 0 SPACE KffCHEN OUTLETS 900 20 1 11 12 0 4400 " 0 1 14 1 20 305 BATH LIGHTING/POWER SPACE 0 13 14 0 SPACE FRIDGE 1500 20 1 13 14 1 20 1500 WASHER � GARAGE OUTLETS 1080 20 1 15 16 1 20 0 FLAG LIGHTING(FUTURE) SPACE 0 15 16 0 SPACE MW 1500 20 1 15 16 2 30 2500 DRYER GARAGE OUTLETS 1080 20 1 17 18 1 20 1800 HAND DRYER SPACE 0 17 18 0 SPACE DW 1500 20 1 17 0 � SPACE 0 19 20 1 20 1800 HAND DRYER SPACE 0 19 20 0 SPACE DISP 1500 20 1 19 20 1 20 250 FC-3 SPACE 0 21 22 1 20 720 OFFICE OUTLETS SPACE 0 21 22 0 SPACE SPACE 0 21 � SPACE 0 23 24 1 20 320 MEZZANINE LIGHTING SPACE 0 23 24 0 SPACE BED OUTLETS 900 20 1 23 24 0 SPACE � ENGINE BLOCK HEATERS 1800 20 1 25 26 0 SPACE SPACE 0 25 26 0 SPACE BATH OUTLETS 230 20 1 25 26 0 SPACE � EXTERIOR OUTLETS 720 20 1 27 28 0 SPACE SPACE 0 27 28 0 SPACE SPACE 0 27 28 0 SPACE � D I T 0 0 2 30 0 SPACE SPACE 0 29 30 0 SPACE SPACE 0 29 30 0 SPACE � TOOL OUTLETS 900 20 1 31 2 0 SPACE SPACE 0 31 32 0 SPACE 0 0 34 0 SPACE SPACE 0 33 34 0 SPACE 0 0 SPACE 0 35 36 0 SPACE SPACE 0 35 36 0 SPACE 0 0 SPACE 0 37 38 0 SPACE SPACE 0 37 38 0 SPACE 0 0 INFORMATION KIOSK 1500 20 1 39 40 0 SPACE SPACE 0 39 40 0 SPACE 0 0 AEC PROJECT#: 12017 LV TRANSFORMER 500 20 1 41 42 0 SPACE SPACE 0 41 42 0 SPACE 0 0 LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY DATE: ISSUE: + ' ' 12-19-12 DRYER VENT REV. � CALCULATED POWER FACTOR: PROVIDE FEED THROUGH LUGS FOR CONNECTION TO FUTURE GARAGE B PANEL CALCULATED POWER FACTOR: PROVIDE FEED THROUGH LUGS FOR CONNECTION TO FUTURE GARAGE B PANEL CALCULATED POWER FACTOR: � 0.97 #DIV/0! 0.99 12-19-12 RFC #067 � CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS 01-02-13 REVISION #11 LIGHTING 3047 8 3047 8 LIGHTING 0 0 0 0 LIGHTING 1000 3 1000 3 11 RECEPTACLES 15620 43 � 12810 35 RECEPTACLES 0 0 � 0 0 RECEPTACLES 6370 18 6370 18 02-06-13 ASI # 015 1� MECHANICAL 3850 11 4300 12 MECHANICAL 0 0 0 0 MECHANICAL 1600 4 � 1975 5 03-07-13 ASI # 016 1 KITCHEN 0 0 0 0 KITCHEN 0 0 0 0 KffCHEN 19800 55 12870 36 TOTAL 22517 62 20157 56 TOTAL 0 0 0 0 TOTAL 28770 80 22215 62 03-25-13 ASI # 016 REVISION 1 Drawn By: Checked By: CTL AEC PANEL S CHEDULES SCALE: NONE • 3 of 10 m COPrRIGtiT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N � ) B r `� � � � � o � � � � � � r °ORAGE � � � o � � WP GFI '�� � L � U � � (n � -d�' SHEET DETAIL NOTES: o .� o > o � � � oti U � � �� � 1O PROVIDE CONNECTION AT CEILING FOR TRUCK POWER. COORDINATE � � Q � � . . LOCATION WITH OWNER PRIOR TO ROUGH-IN. �--�--r- � -r-r- - ----- --�--r-� X � I i i i ii i i i i i i i � � �}' CV N U � � i i i i ! � � � i C '� N I � O2 PROVIDE LOW VOLTAGE CONNECTION FOR ANY AUTOMATIC TOILETS UP - i i i i i i � �L'" -+-� � � OR SINKS. COORDINATE LOCATION OF CONNECTION WITH PLUMBER � I i i� i i GARAGE A-5 i i I � � U O.� PRIOR TO ROUGH-IN. STAI R � _ �I � '/ ' � � �S � N � U O3 PROVIDE MOTOR-ACTUATED DAMPER FOR GENERATOR. INTERLOCK - - - - - - - - - - - - - - i�Y���C-l� � � � ACTUATOR WITH GENERATOR RADIATOR FAN. 1 2� .� U � �� � O4 COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH DN TO w C� W � ~ � MECH-24,26 � J 2 O � M E C H A N I C A L C O N T R A C T O R P R I O R T O C O N S T R U C T I O N. U P S T A I S W p W P � � I` � i �� ZH GFI GFI � W� � � O MAINTAIN EXISTING FIBER OPTIC CONNECTION. DO NOT DISTURB � � ENTRY IN ANY WAY, THE FIBER OPTIC CABLE SERVES OTHER � __- J HAND U U V O C BUILDINGS NEARBY. � � , � DRYER � � � O � � O GFI �� GARAGE � HAND GARAGE A-41 }, � O � Q O6 LOCATE POWER CONNECTION IN CEILING FOR WIRELESS INTERNET, 2 q_�g DRYER PARTIAL '- U � COORDINATE LOCATION WITH OWNERS PRIOR TO ROUGH-IN. � O � � Q pp � O7 PROVIDE DISCONNECT SWITCH ON BACK WALL FOR AIR EM-11 EM-13� HOSE DRY ` GARAGE A-1 GARAGE A 20AGE � � i � � ~ COMPRESSOR. COORDINATE EXACT LOCATION WITH OWNERS PRIOR � i A PARTIAL A-39 Q XO TO ROUGH-IN. � � � -�J m ,� Y FACP UH KIOSK 2 O8 PROVIDE JUNCTION BOX AT EDGE OF MEZZANINE FLOOR TO CONNECT /v' � O J � TO THE AIR FILL STATION. COORDINATE EQUIPMENT CONNECTION � J WITH OWNERS PRIOR TO ROUGH-IN. � � O i J MECH-36,38 M O �� 1„�7,�r �,,t 2 ���5''j� .,_I t�k �?, To GARAGE A GFI J GARAGE A-3 C7 �-I �, `-. e � � . GARAGE EM-15 �C �� PANEL PARTIAL GFI � t. _� ��Z��, __ GENERAL NOTES. A_25 � 2 2 HRV M �� -�. � �-�`, � � i � MECH-40 � � GARAGE B O 1 PANEL � � To " �, ,�7 �:,' .: *_ 1. ALL GFCI AND WATERPROOF-GFCI RECEPTACLES SHALL BE PROVIDED � MECH-21 � �:,�,� t, `t� WITH METALLIC JUNCTION BOXES AND COVERS. PROVIDE METALLIC � - — - — - '— - ��1��'cy����,��r.� �,ti`'� JUNCTION BOXES TO ENSURE PROPER GROUNDING AND TO AVOID r � � _ _ � G E N S ET P �1�-t'�.}:urr���cL���L�: NUISANCE TRIPS. PROVIDE METAL COVERS TO FOR EASY IDENTIFICATION i ANNUNCIATOR GFI OF GFCI RECEPTACLES. � I WE� I GFI GFI +12'AFF 2. COORDINATE GARAGE DOOR MOTORS WITH OWNERS. PROVIDE MANUAL � EM-17� I GARAGE EM-30 M 70 OPERATION IN CASE OF POWER OUTAGE. MECH-28,30 I A-13 - � GARAGE � UH � 1 U P � � DOOR � N � � � � � �� � ��� i i Q EM-25 � POLE � �� � i � O �. � � M-27 -- � i i -----� O � �O5 � TOI� ;„� MECH-16 EM'22 i � = UH GARAGE A-14 � PARTIAL O O �TE� � �H qC J 1e PARTIAL MECH-16 � � � 1 J HEATER PARTIAL i Q � GFI EF GFI IGNITION � � HEATER I MECHANICAL SCHEDULE [ EM-21,23 MECH-32,34 M To � � � � O IGNITION � M TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS GFI J � w THERMAL � � �-- � - � � - - - - - B-1,2 BOILER 500W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P GFI EM-2$ M To � O PROTECTION C� > GARAGE U CH-1 CHILLER 28.8 FCA 208 1 (4#12CU,1#12CUG)1"C 60/2 40A2P ��C�N GARAGE POW R DOOR � ^ G F I A-15 I..I..I O J � CU-1 CONDENSWG UNIT 26.4 MCA 208 1 (3#8CU,1#12CUG)1"C 60/2 40A2P I � Q � � THERMAL I��. �-�� � ��� �s�� . �� � � EF-1 EXHAUST FAN 21 W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1 P I..I..I � � PROTECTION I 124 � � THERMAL AIRM I I � � EF-2 EXHAUSTFAN 62W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P PROTECTION COMPRESSOR � � EM-24 J THERMAL M 8 I I MECH-16 � FC-1,2,5 FAN COIL 1/6HP 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P � PARTIAL PROTECTION � THERMAL O HEATER � FC-3,4 FAN COIL (2)1/6HP 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P EM-18,20 EM-26 IGNITION PROTECTION � 1O THERMAL � � GFI � � GARAGE � GF-1,2,3 GLYCOL FEEDER 50W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P � GFI A-31 � EM-26 M PROTECTION To TRUCK GARAGE THERMAL POWER HRV-1 HEATRECOVERYVENTILATOR 610W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P DOOR PROTECTION AEC PROJECT#: 12017 I I I P-1,2,3 PUMP 92W 208 1 (3#12CU,1#12CUG)1"C 30/2 20A2P GFI � I I DATE: ISSUE: THERMAL � � P-4 PUMP 45W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P I I 12-19-12 DRYER VENT REV. g PROTECTION THERMAL � I � 12-19-12 RFC #067 � P-5 PUMP 85W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P GFI 7 I 01-02-13 REVISION #11 11 PROTECTION 02-06-13 ASI # 015 1� ACTUATED � P-6 PUMP 370W 208 1 (2#12CU,1#12CUG)1/2"C 30/2 20A2P LOUVER 03-07-13 ASI # 016 1 03-25-13 ASI # 016 REVISION 1 EM-12 MECH-16 EM-16 Drawn By: Checked By: P-7 PUMP 1/2HP 208 1 (2#12CU,1#12CUG)1/2"C 30/2 20A2P O EG_'� EM GARAGE A-17 CTL AEC ACTUATED PANEL GFI GFI O— 4O GFI 3 LOUVER GFI M M ELECTRIC UNIT HEATER SCHEDULE OREQUIVALEN � 1 T� T� LOWER � � ELECTRICAL DATA DIMENSIONS OPER. M GAS WP LEVEL UNIT MANUFACTURER& CAPACITY EAT LAT ENGINE TAG MODEL NO. SERVICE LOCATION �gTUH) (°F) (°F) KW AMPS V/PH/Hz L(IN) H(IN) W(IN) �LBS� REMP,RKS EXHAUST RADIANT GFI FAN HEATER POWER UH-1 RAYWALL SEE PLANS WALL MOUNTED 2560 45.0 95.0 0.75 3.1 208/1/60 17 8 3.5 - INTERLOCK W/T-STAT,CONSULT LOCAT�ON W/ARCHITECT MAIN CT (PLYMO-VENT) HF4475T2RP DISCONNECT NORTH UH-2 RAYWALL SEE PLANS WALL MOUNTED 6826 45.0 95.0 2.00 8.3 208/1/60 17 8 3.5 - INTERLOCK W/T-STAT,CONSULT LOCATION W/ARCHITECT PLAN HF4420T2RP LOWER LEVEL UH-3 RAYWALL SEE PLANS WALL MOUNTED 3413 45.0 95.0 1.00 4.2 208/1/60 17 8 3.5 - WTERLOCK W/T-STAT,CONSULTLOCATION W/ARCHITECT SCALE 1/4�� = 1�-��� H F4410T2 RP POWER & SYSTEMS PLAN � �_� SCALE: 1/4"= 1'0" • 4 of 10 m COPrRIGtiT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N � � � � � `� � � � � � � � � � � LOCATE CONNECTIONS AT PLATFORM ABOVE � V � O � MECHANICAL EQUIPMENT. COORDINATE NORTH STAIR � � p � CONNECTION LOCATIONS WITH TOWN OF VAIL. � � �N U ap � � � � � � EM-32,34 EM-36 � � � O ~ MECH-31,33 O � OQO J I HEAT 1O U � � -� � � . J d' TRACE � � � � . . 30A2P 20A1P � �� N X O G E N E RAL N OT E S. IT RACK IT ANTENNA TO � (a U CIRCUIT MECH-19 DOWNST IRS �L, -� � � � _ MECH-11,13 � � � (n �� 1. ALL GFCI AND WATERPROOF-GFCI RECEPTACLES SHALL BE PROVIDED � V WITH METALLIC JUNCTION BOXES AND COVERS. PROVIDE METALLIC M To EF UH ` � J Q N O > JUNCTION BOXES TO ENSURE PROPER GROUNDING AND TO AVOID � MECH-27,29 e � e3 I I I I N I MECH-15,17 � oZS � V LOCATE CONNECTIONS IN MECHANICAL ROOM. COORDINATE CONNECTION � � � � NUISANCE TRIPS. PROVIDE METAL COVERS TO FOR EASY IDENTIFICATION r��� ��E � •� LOCATIONS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. HEAT � Q � 00 � OF GFCI RECEPTACLES. TRACE � � � •V W � L �'� �j EM-19 MDP MECH 3H w � J 2 O � � - PANEL GFI O � W � � � � B B GF 2F 3F CH - - - - - c WP � GFI _ GFI � � � � dj U N O � M M M M M RANGE M�/ � �� � � Q M TO TO TO TO TO AC AC � � 0 EM-1 MECH-2 MECH-22 MECH-1 3 E H U A-1 A F I � GFI GFI DORM A-21 SHEET DETAIL NOTES: , ` G AC GFI DORM A-23 (� � Q � � I STUDIO GFI DORMA-11 � � 1O LOCATE CONNECTION FOR HEAT RACE AT ROOF. COORDINATE � M TO EF DORM A-17 DISP � p LOCATION IN FIELD PRIOR TO ROUGH-IN. P 2 3 4 5 6 7 � ��9 EHU A-7 e AC DORM A-15.�� m O PROVIDE HOLIDAY LIGHTING RECEPTACLES UNDER ROOF EAVE, ��v�-� ��p�-� ��� M M ��p�-L ��Ip�-L GFI O �:.�n ��.��_n L.ei_�i �..+�n �..�n COORDINATE LOCATION WITH OWNERS PRIOR TO ROUGH-IN. � � � To TO � � pW EHU A-17 DORM A-13- n\n'� EM-3,5 MECH-4,6 MECH-8,10 EM-7 MECH-12 MECH-14,16 MECH-18,20 GFI EHU A-3 I A� �� LIVING 1�;�7� rr DISP {���j� � �' �-� �'���, - .+ ,,,'� '`' � �� � � I AC '�!�' = GFI Y : ,f ,� ��EHU A-19 � � 1 �� ��'�1� -. �O GFI DORM A-1 22 'rj I t°��„ RANGE EHU A-9 4 � � � AC MW EHU � DORM A-3 -�; • � -��:t U • �` GFI EHU A-15 A-21,23 FRIDGE � ��� �} �� EHU A-15 EHU A EHU A-5 DORM A-7 DORM A-9 DORM A-19 • • � *.'� ��' `" � PANEL — EM-10 WP , ¢��.�� t` ' yY. zT a e n � AC �r?,`_'�y`,7NAu t�r:� },��`: � GFI AC GFI EHU A-14 FRIDGE FRIDGE FRIDGE +12'AFF �`�''�r+�:urri��tLYl�`� W� GFI ,�� DRYER FC �i �,� I 226 E"u e I 214 • LOCATE CONNECTIONS IN ATTIC SPACE - I A-16,18 i ABOVE HALL AND BATHROOMS. COORDINATE D M TO �� P E DORM A-25 � CONNECTION LOCATIONS WITH MECHANICAL �� - � CONTRACTOR PRIOR TO ROUGH-IN. I 213 DORM B-11 - � "'„"„�' EHU A-20 . • � � � eFC FC � � � • GFI N II � II I'.�, '' ,,{� 4 5e AC ANGE � , •: '" GFI , ; , � DORM B-13 � M T� M To GFI /� DORM A PARTIAL DORM B-7 � AC - EF O EHU e PANEL EF — WASHER �� AC B-10,12 GFI GFI M TO� DORM B M T � EF O MECH-23 MECH-42 GFI B DROO O � DRYER DISP � PANEL �_ � — � EHU B-9 e � EHU B-19 M Q EHU EHU B-14 23� FRIDGE � DORM B-15 T� ORM A-34 ��N �`,�� � � _ WASHER � � B-16 18 EHU B-13 EHU B 11'� PARTIAL DRYER , �� AC GFI GFI AC � � °�� � - - - - - -��; GFI , EHU B � � PANEL �� DORM A-32 W O - � +g'AFF � > C , u �� �� `��' DORM B-9 w � � j�-� IIM w J � � - N � z � � � I _ > � � w � � � EHU B-1 � � '��'�R / LIVING J � II A� �; �.��ROOI�� ����� � �� _ EHU B-3 � GFI � �� DORM B-3 DORM B-5 M _ � - � To NEHU B-25 EF DORM B-1 � � - — - — � 1 - — - — - — - — - — - - — - — - — - — - — - � r � � � GFI EHU B-7 F3 �COS�T EF � AEC PROJECT #: 12017 � M T � M To �� M��38 I _ I DATE: ISSUE: , � EHU B-20� EHU B-23 12-19-12 DRYER VENT REV. � - EHU B-5 9 12-19-12 RFC#067 � � �� GARAGE A 29 01-02-13 REVISION #11 � � EDROOM 02-06-13 ASI # 015 � 2 03-07-13 ASI # 016 � � 239 GF 03-25-13 ASI # 016 REVISION 1 242 I � Drawn By: Checked By: MECH-39,41 � MECH-35,37 � O CTL AEC HEAT � � � � HEAT TRACE 1 � � � - - - - - - - - - - - - - - - - - - - - - - - TRACE UPPER 1 ; _ � M �� LEVEL 1 MECH-5,7,9 POWER NORTH UPPER LEVEL PLAN S CALE 1/4" = 1'-0" POWER & SYSTEMS PLAN � SCALE: 1/4" = 1'0" • 5 of 10 �COPYRIGNT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N � � � � `� � � SHEET DETAIL NOTES: -�' � � � � � � 1O PROVIDE PUSH BUTTON TO TURN ON ALL RED'CALL' LIGHTS � STORAGI � U (6 p N SPECIFIED AND TURN OFF ALL OTHER LIGHTS, COORDINATE PUSH I � �� � U O�p BUTTON LOCATIONS WITH FIRE DEPT PRIOR TO INSTALLATION. WIRE i � � � �N pp PUSH-BUTTON CONTROLS SO THAT ALL DESIGNATED RED'CALL' � � tA �� LIGHTS IN THE BUILDING ARE TURNED ON WHEN ANY PUSH-BUTTON IS � � � � ~ ACTIVATED. .� � Q � � O � O U �, � � O2 LOCATE ALL B FIXTURES AT+g'AFF. ENSURE THAT ALL SUSPENDED 9O UPSTAIRS N '� O � � � � FIXTURES WITHIN ANY SPACE ARE AT THE SAME HEIGHT. -_ +8'AFF JQ � � � N � � TO y GARAGE A-20 � � -� � � _ O3 CONTROL EXTERIOR LIGHTS WITH PHOTOCELL SENSOR. DISCONNECT UPSTAIRS �i PARTIAL �L-- � N � - FROM POWER WHEN 'RED' CALL LIGHTS ARE ACTIVATED. GARAGE A-6 i � � V �(� PARTIAL � � 3 � J U �O � O4 PROVIDE IN GROUND JUNCTION BOX FOR FUTURE FLAG POLE, RUN 1 � O O � o� Q N � V 1/2" CONDUIT WITH PULL WIRE FROM GARAGE A PANEL TO FLAG POLE GARAGE A-20 O � AA AA _ .� - � � � ('a LOCATION. COORDINATE LOCATION WITH FIRE DEPARTMENT PRIOR PARTIAL H HO GARAGE A 16 � V Q �� TO ROUGH-IN. O O3 -14 w ,� W ?� f` � � PA IAL 4 � J 2 O � OCONNECT ALL BALLASTS CONTROLLING 'RED'LAMPS TO CIRCUIT EM-2, AA AA � OJ � W � � O� � AS ALL'RED' CALL LIGHTING NEEDS TO BE ON A GENERATOR CIRCUIT. O H M M M � =�� � AND CONNECT ALL BALLASTS CONTROLLING 'WHITE' LAMPS TO � CIRCUIT GARAGE A-10, THESE DO NOT REQUIRE GENERATOR � - - - +8'AF '+'' U N O � BACK-UP. � GARAGE A-6 � V � �� o � PARTIAL � � s � � � O PROVIDE CONNECTION FOR NEW POLE LIGHT. POLE& FIXTURE ARE 1 "^ M � � � �� TO BE PROVIDED BY THE TOWN OF VAIL, CONTRACTORS ARE OO OO O O3 � U Q pp � RESPONSIBLE FOR PROVIDING CONCRETE PAD, ELECTRICAL � A A � � � CONNECTION, AND FIXTURE INSTALLATION. CONNECT TO EXISTING B B A a LIGHT POLE CIRCUIT TO THE WEST IF POSSIBLE, OTHERWISE A I A A � �` p CONNECT TO CIRCUIT GARAGE A-16 WITH FLAG POLE. � - m EM-14 � O7 PROVIDE 3-WAY SWITCH (SQUARE D MODEL 9001 KS466H28)TO PARTIAL � OPERATE MAP LIGHTS (FIXTURE 'O')WHEN THE STANDARD LIGHTS GARAGE A-1 ARE ON, OR WHEN THE RED LIGHTS ARE ON. ONE OF THE TERMINALS � � O �i- PARTIAL A A ON THE 3-WAY SWITCH SHALL BE CONNECTED TO CIRCUIT GARAGE M GARAGE A-1 ;1„�7=�r �,, ri, A-10 TO OPERATE MAP LIGHTS DURING STANDARD LIGHTING. O O PARTIAL PARTIAE A-3 R{t��`Y�`.,_� � 'f�,�•fY ANOTHER TERMINAL SHALL BE CONNECTED TO CIRCUIT EM-2 TO � ;` ::'` �[7 �--I .Z� OPERATE THE MAP LIGHTS DURING THE RED LIGHTING,AND THE LAST ``°�?�` - GARAGE A-20 q q A A �,�, - � � TERMINAL SHALL BE OPEN TO TURN OFF THE MAP LIGHT. COORDINATE PARTIAL OO B B -�, M P` _ - LOCATION WITH FIRE DEPARTMENT PRIOR TO ROUGH-IN. � � " - ' �- B B I N 1O �' �� ���� q q "' `� " � �. � ,�7 �,�, ' � 1 EM-14 H N ��� � - ;` � • � PARTIAL ¢��� �'�"7NAu '�' ,,�,'� � � �t�� � t 1�.t1r/2;i71tidttYlSL�. p , • O O GARAGE A-20 EM-14 ARTIAL GENERAL NOTES: O � PARTIAL � F F� BB � o o �� � 1. PROVIDE ADDITIONAL OCCUPANCY SENSORS AS NECESSARY TO PROVIDE GARAGE A-4 A A � FULL COVERAGE OF ANY AREA. IN CORRIDORS, OCCUPANCY SENSORS PARTIAL � � SHALL BE LOCATED TO ACTIVATE IMMEDIATELY WHEN ANYBODY ENTERS M � GARAGE A-8 THE CORRIDOR. IN STAIRWELLS, PROVIDE OCCUPANCY SENSORS AT ANY PARTIAL � DOOR TO THE STAIRWELL AND ANY LANDINGS. Q p EM-2 2. ENSURE THAT ALL LIGHTING FIXTURES ARE NOT WITHIN THE CLEARANCES N � PARTIAL O Z FOR THE GAS-FIRED HEATERS. THE MINIMUM CLEARANCE BETWEEN ANY COMBUSTIBLES AND THE HEATER IS 8"ABOVE, 40"TO THE SIDE AND 80" �i A A BELOW. M --li � N -�i O i GARAGE A-8 I� PARTIAL T� O UPSTAIRS � � GARAGE A-12 A Q � PARTIAL M GARAGE A-14 F �O F �O � � � I N q PARTIAL � j � _—- � �� � � Q 0� � cc w 0 GARAGE A-8 � � GARAGE A-12 PARTIAL LUMINAIRE SCHEDULE PARTIAL FO � EM-2 � ., PARTIAL 5 O J TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING NO LAMP VOLTS DIMENSIONS REMARKS O w A RECESSED DOWN LIGHT PRESCOLITE IBX261CATDM-SBH-T06 RECESSED 1 26W TRIPLE TUBE CFL 120 7 7/8"W X 10 3/4"L X 7 1/2"H E z � � � � o II , e w �� , w .� .� � - > B SUSPENDED LINEAR FLUORESCENT ALERA CVRPB-4-3T8- -CM-48-ED-U-MW-SCE- SUSPENDED 3 32W T8 120 48"L X9 1/2"W X2 1/2"H � �� � � � GARAGE A-12 � COORD FINISH WITH OWNER PARTIAL � w C CEILING FAN W/ LIGHT EMERSON FANS HIGHPIOINTE SUSPENDED 2 50W HALOGEN 120 54"DIA � CANDELABRA � D LINEAR FLUORESCENT WALL FIXTURE COLUMBIA W4-232-EP-U WALL 2 32W T8 120 48"L X4 7/8"X4"H SURFACE F 1O F 9O F 1O ���,� N E 4'FLUORESCENT UTILITY WRAP COLUMBIA WC4-232-EPU SURFACE 2 32W T8 120 48"L X10"W X2 1/2"H � DAMP LOCATION FOR 2-LAMP BALLAST PROVIDE O3 � F LINEAR FLUORESCENT HIGH BAY COLUMBIA LHC24-654-FACA-LS-24EPU SUSPENDED 6 54W T5H0 120 24"W X48"L X5"H LAMPS WITH RED MALCOLITE CC DAMP LOCATION-GASKETED TUBE GUARD E � EM-35 PARTIAL G PENDANT PRESCOLITE RDPSCFT SUSPENDED 1 26W TRIPLE TUBE CFL 120 E -2 PARTIAL O5 AEC PROJECT #: 12017 H RED EGRESS STEPLIGHTS 10 LIGHTING 0-01-SL-R-R-5-0 WALL 1 8W LED 120 9 5/8"L X6"H X3 3/8"D RECESSED ( INCLUDED) DATE: ISSUE: I NATURAL LIGHT TUBE SOLATUBE 160 DS RECESSED N/A N/A N/A 10" DIA � 12-19-12 DRYER VENT REV. g J BATHROOM VANITY LIGHT PROGRESS P2709-09EBWB SURFACE 4 13W CFL 120 30"W X7 1/2"H � EM-35~� 12-19-12 RFC#067 � � PARTIAL 01-02-13 REVISION #11 � EM-2 02-06-13 ASI # 015 � K LED STRIP LIGHTS GM LIGHTING LTAB-N SURFACE 2.8W/ FT 12V DC COORDINATE ALL LENGTHS IN FIELD O PARTIAL UNDERCOUNTER 3500K PROVIDE DRIVERS PER MANUF REQ�s. ' 03-07-13 ASI # 016 1 L LED STRIP LIGHTS GM LIGHTING LTR300WP-WW SURFACE 2.6W/ FT 12V DC COORDINATE ALL LENGTHS IN FIELD O3-Z5-�3 ASI # 016 REVISION 1 WET LOCATION 3500K PROVIDE DRIVERS PER MANUF REQ'S. E FO FO FO Drawn By: Checked By: EN� GARAGE A-12 CTL SOH M STAIR SCONCE BORDEN 504-CF1\26-120-SAL SURFACE 1 26W TRIPLE TUBE CFL 120 � PARTIAL O 3 N SURFACE WRAP COLUMBIA AD-2-1-17-E-U SURFACE 1 17W T8 120 � CC LOWER O MAP LIGHT COLUMBIA SLA4-132-ROW/SLBI-2-32 SURFACE 1 32W T8 120 I �I 3 LEVEL PROVIDE SQUARE LENSED SHOWER AA S SHOWER RECESSED DOWNLIGHT LIGHTOLIER 1050SQDLFGWB RECESSED 1 26W TRIPLE TUBE CFL 120 7 7/8"W X 10 3/4"L X7 1/2"H TRIM. COORD W/OWNERS �NI� LIGHTING WET LOCATION LISTED AA EXTERIOR RECESESD DOWNLIGHT HALO H285EICAT-26WDTT-406SC RECESSED 1 26W TRIPLE TUBE CFL 120 13"L X9 1/2"W X7 1/2"H LOW E R L EVE L L I G H TI N G P LAN PLAN S CALE 1/4" = 1'-0" BB EXTERIOR RECESSED DOWNLIGHT HALO H2471CAT RECESSED 1 26W TRIPLE TUBE CFL 120 14 3/4"L X 10 1/2"W X7"H SCALE: 1/4" = 1'0" SLOPED CEILING FIXTURE � � � �� � CC EXTERIOR WALL SCONCE SHAPER 682-WP-11-CFL/2-120-NBZ-BN-PH SURFACE 1 26W TRIPLE TUBE CFL 120 12"D X 11"W X 10"H NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. � 6 of 10 �COPYRIGNT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N � � ( � � � � � � � o � � � � � � � � —° � DORM A-6 � � � U 00 PARTIAL 21 n � �N �� � � �a ti C � O , L 5 L � O O U � � �� O d' � DORM A-6 T� H H � � N � X O PARTIAL DOWNSTAIRS � ��' N (� U H O �L-- -�' '� � LL = TO � � � � .� SHEET DETAIL NOTES. DOWNSTAIRS M M a� �'Q N� ? � °'� � �LS o�o � 1O PROVIDE PUSH BUTTON TO TURN ON ALL RED'CALL'LIGHTS — .� c� � C� pp � SPECIFIED AND TURN OFF ALL OTHER LIGHTS, COORDINATE PUSH E "' � •L W >+� � BUTTON LOCATIONS WITH FIRE DEPT PRIOR TO INSTALLATION. WIRE w V J 2 O � PUSH-BUTTON CONTROLS SO THAT ALL DESIGNATED RED'CALL' EHU A-2 N LIGHTS IN THE BUILDING ARE TURNED ON WHEN ANY PUSH-BUTTON IS PARTIAL � (6 W � ? p� � ACTIVATED. � � E M L' �'� "� - - - - - - - - � 2 LOCATE ALL B FIXTURES AT+9'AFF. ENSURE THAT ALL SUSPENDED r A A � O U '� .0 � p O F I X T U R E S W I T H I N A N Y S P A C E A R E A T T H E S A M E H E I G H T. / � � H � 1 H � � � O � � �� �� � M L� ,� � � ° � K � a--� � � � � OPROVIDE A DEDICATED SWITCH FOR FAN CONTROL,AND A DEDICATED EHU A-2 �� DORM A-4 � G EM-6 BB � � � dj� SWITCH FOR THE FAN LIGHT. PARTIAL �r PARTIAL DORM A-4 � � a p�p ~ O4 PROVIDE RED LENS FOR SPECIFIED DOWNLIGHT. CONNECT TO PUSH A A S PARTIAL Q O BUTTON 'CALL' LIGHT CIRCUIT. A A BB � EHU A-2 M EHU A-4 EM-33 � � G m OLOCATE FLUORESCENT FIXTURE BELOW PLATFORM, LOCATE LED PARTIAL PARTIAL PARTIAL O O STRIP LIGHT ALONG PERIMETER OF ANTENNA ROOM. PROVIDE � „Y J � PHOTOCELL CONTROL MOUNTED AT EXTERIOR FOR LED STRIP K = LIGHTS. � G q EHU A-4 A A � ;11;trrrr �rrri, PARTIAL G ��`j �� ��� `��. O6 PROVIDE PHOTOCELL LIGHTING CONTROLLER WITH MANUAL SWITCH O C +`s ''` ' ' , ` - . ,, � Y^ FOR LIGHTS ON DECK AREA. COORDINATE SWITCH LOCATION WITH � cti�.}f �� �-��� _ OWNERS. DISCONNECT FROM POWER WHEN 'RED'CALL LIGHTS ARE BB ��`� - � �.:: - ACTIVATED. - - PARTIAL C K A A A DORM A-2 " ' � � �k � �� ;_` � � PARTIAL O6 '�� `�' `'� � � DORM A-2 t ¢ ;� `� ~~ 4, � — — — — — -- K O PARTIAL — — � p ���t�1�'�'7�VAu t lsi ,�'`': � D �r+t,urri�itL� � A EHU A-4 N�' ' / � p PARTIAL 1O H 3 I , EM-33 EM-33 PARTIAL . DORM A-2 N PARTIAL G G PARTIAL � " O A � A A � r H � O BB � M M NI A L H D D �� HO �k TO DOWN- � � DORM B-6 Q � PARTIAL STAIRS O q � I � O1 � S S z / DORM B-15 DORM B-2 M M K PARTIAL M � � PARTIAL O C M EHU B 4 1 DORM B-13 TO D WN- PARTIAL PARTIAL A H PARTIAL A O STAI RS O � K v M M � , ^ A OI A o' A E � � EHU B-2 A � O q EM-4 BB � � PARTIAL _ � A H r O - - - - - � � � M � pp �� - N — � - - - - � � J w O DDD � EHU B-2 DORM B-2 `�' H O3 PARTIAL PARTIAL U .-..-. � EHU B-4 A A A EM-33 A A PARTIAL I� 1O H "' A T � w � � , 0 � , M 0 �/ �- Q BB i G ❑ > ; JI! I..� � EHU B-2 i � PARTIAL � � w � A A � t i '� w �<� � � ��� � � �_ C � EHU B-6 C C PARTIAL � A A 5 � � A A DORM B-4 DORM B-4 DORM B-6 � � - — - — - — PARTIAL PARTIAL PARTIAL � r EHU B-2 3 PARTIAL � � � EHU B-8 � 3 = — - � PARTIAL - N AEC PROJECT #: 12017 � A A S A A M M EHU B-6 EHU B-2 PARTIAL DATE: ISSUE: PARTIAL 12-19-12 DRYER VENT REV. � 9 , n 12-19-12 RFC#067 � � � 01-02-13 REVISION #11 � A s 02-06-13 ASI # 015 � � 03-07-13 ASI # 016 � � 03-25-13 ASI # 016 REVISION 1 I y C EHU B-6 PARTIAL Drawn By: Checked By: EHU B-8 � CTL SOH PARTIAL N + EHU B-8 � 1 - - - - - - , PARTIAL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UPPER � � I LEVEL NORTH LIGHTING UPPER LEVEL LIGHTING PLAN PLAN S CALE 1/4" = 1'-0" SCALE: 1/4" = 1'0" � � � �s� • 7 of 10 �COPYRIGNT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC. 0 N tfl LIGHTING CONTACTOR: SQUARE D MODEL � � 8903L01200-V02-Al2 WITH HOLDING • • • PROVIDE PUSH BUTTONS TO ENGAGE RED-LIGHT � � �, � � CIRCUIT INTERLOCK AND 9991 ENCLOSURE, SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION). � �� o o � C O N V E R T T O N O R M A L L Y-C L O S E D.W H E N PROVIDE SQUARE D MODEL 9001 KXRB1 PUSH � � �� �� � � � o , CONVERTING THE CONTACTOR TO BUTTONS WITH LABELS TO OPERATE CONTACTORS. o .� o Q o N O R M A L L Y C L O S E D T H E R E A R E A T O T A L PROVIDE LOW VOLTAGE TRANSFORMER ON PANEL U o � �� � O F 8 P O L E S A V A I L A B L E. EM FOR THE PUSH BUTTON POWER. � �'� � ,�� � � � � �� � J�-' cUi �o > aNN � °'� � �LS o�o � CONNECT THE FOLLOWING CIRCUITS � .� w ,�� o � � � FROM PANELS DORM A & B TO THE w � J20 � POLES OF THE LIGHTING CONTACTOR: � W� � � � � � - '�'' U N O � U �� .� o0 0 � � STAN DARD � � � ° � _ DORM � LIGHTS � � � � �' i � Q � � DORM B - 2 '4 & B � °° PANELS a " DORM 6 - 4 m DORM B - 6 ° 4 POLES SHALL BE SPARE LIGHTING CONTACTOR: SQUARE D MODEL 8903L01200-V02-Al2 WITH HOLDING 1""''rY'�"Irfk ;� .`S`s�j�`, ; +'F 1 'ffl• , . CIRCUIT INTERLOCK AND 9991 ENCLOSURE, ������'`Y��' "��z,�� .:_.� CONVERT TO NORMALLY-CLOSED.WHEN -i `� - � � �; • �( �'��.t � i CONVERTING THE CONTACTOR TO � �� ��' `�� ��} �� �. . ,: �� t,. :: NORMALLY CLOSED THERE ARE A TOTAL ¢�`�1f`',`��������A��,��}'`' �1��1-!/2;i71 t i d ttY1S 1 CONNECT THE FOLLOWING CIRCUITS OF 8 POLES AVAILABLE. FROM PANELS GARAGE A & B TO THE POLES OF THE LIGHTING CONTACTOR: . GARAGE A - 4 (y �/ GARAGE A - 6 I I � STAN DARD Q - 1 GARAGE I � LIGHTS z G A - 1 A & B I I PANELS Z GARAGE A - 14 O _ O 0 GARAGE A 24 LIGHTING CONTACTOR: S ARE D � — � 2 POLE SHALL BE SPARE QU 0 � MODEL 8903L060-V02-Al2 WITH Q � � HOLDING CIRCUIT INTERLOCK AND � Q � � 9991 ENCLOSURE, NORMALLY OPEN. W O � > THIS CONTACTOR HAS A TOTAL OF 6 U � � POLES. O J �..I � CONNECT THE FOLLOWING CIRCUITS REDLIGHT z Q � � FROM PANEL EM TO THE POLES OF THE CIRCUITS � LIGHTING CONTACTOR: � � RED w � - I �"L EM 2 � LIGHTS � W EM - 4 EM � I J EM - 6 PANEL — 3 POLES SHALL BE SPARE Q � N d' CONNECT THE FOLLOWING CIRCUITS STANDARD FROM PANEL EM TO THE POLES OF THE LIGHT � LIGHTING CONTACTOR: CIRCUITS I PROVIDE PUSH BUTTONS TO DIS-ENGAGE RED-LIGHT AEC PROJECT #: 12017 EM - 33 SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION). DATE: ISSUE: EM - 35 LIGHTING CONTACTOR: SQUARE D MODEL PROVIDE SQUARE D MODEL 9001 KXRB1 PUSH BUTTON 12-19-12 DRYERVENTREV. �g EM - 14 8903L060-V02-Al2 WITH HOLDING CIRCUIT WITH LABEL TO OPERATE CONTACTORS. PROVIDE LOW 12-19-12 RFC#067 � VOLTAGE TRANSFORMER ON PANEL EM FOR THE PUSH 01-02-13 REVISION #11 0 3 POLES SHALL BE SPARE INTERLOCK AND 9991 ENCLOSURE, 02-06-13 ASI # 015 � CONVERT TO NORMALLY-CLOSED. TH IS ' BUTTON POWER. 03-07-13 ASI # 016 , � CONTACTOR HAS A TOTAL OF 6 POLES. 03-25-13 ASI # 016 REVISION 1 Drawn By: Checked By: CTL SOH RED LIGHT WHAT IS SHOWN ABOVE IS DIAGRAMMATICAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTROL PROVIDE ALL EQUIPMENT NECESSARY TO OPERATE THE SYSTEM. COORDINATE EQUIPMENT ONE-LINE REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH-IN, VERIFY EQUIPMENT COMPATIBILITY WITH DIAGRAM THE MANUFACTURER IN ORDER TO PROVIDE A FULLY OPERATIONAL SYSTEM AS REQUIRED BY THE SCALE: NONE OWNERS. . 1 of 1 �COPYRIGNT 2005 ARCHITECTURAL ENC�NEERING CONSULTANTS,INC.