HomeMy WebLinkAboutA13-0015 DATA SHEETS.pdf INTELLIKNIGHT ACCESSORY SILENT SK-Photo KNIGHT and SK-Photo-T by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description Plug-in mounting provides ease of SK-Photo and SK-Photo-T are 9-.lu in installation p type smoke sensors that combine a Tamper-proof feature available on - - photoelectric sensing chamber with mounting bases addressable analog communications. Listed for use in duct applications �► Point ID capability allows each detector's address to be set with rotary Rotary address switches for fast address switches, providing exact installation detector locations for selective UL Listed • maintenance when chamber FM Approved contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a Specifications unique optical sensing chamber that is -- engineered to sense smoke produced Physical by a wide range of combustion Height: 2.0" (5.0 cm) SK-Photo (Base included) sources. In the SK-Photo-T, dual Diameter: 4.1" (10.4 cm) electronic thermistors add 135°F (57°C) Shipping Weight: 5.2 oz. (147 g) Compatibility thermal technology to maximize The SK-Photo and SK-Photo-T are detection. Electrical Operating Voltage: 15-32 VDC compatible with the following Standby Current: IntelliKnight FACPs: Features 300 pA @ 24 VDC Maximum 5820XL 5808 • Sleek, low-profile design Alarm Current: 6.5 mA @ 24 VDC max 5700 • Base included (with LED on) 5600 (Rev 2.0 or higher) • Reliable analog communications for Environmental SK-Photo and SK-Photo-T are trouble-free operation Operating Temperature compatible with the following detector • Age resistant polymer housing SK-Photo: 321— 120°F (0°C—49°C) bases: SK-Photo-T: 321— 100°F (0°C—38°C) B210LP 6" base (included) • Dual electronic thermistor design on Humidity: 10%—93% non-condensing B501 2 wire base the SK-Photo-T B224RB Relay base • Superior EMI resistance for reliability Other Ratings B224BI Isolator base SK-Photo-T Thermal: Fixed g200SR Sounder base • Simple field cleaning for code temperature set point 135°F (57°C) compliance Velocity: 0—4000 fpm (0—20 m/sec) • Variety of mounting options to meet SK-Photo Insect Screen Hole Size: any application 0.016" (0.41 mm) nominal • Dual LED indicators for 3600 visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor®PN RA100Z) INTELLIKNIGHT ACCESSORY Model SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21 OLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC IN OUT Compatible FACP RAt 00Z(Optional) ....................... 3 2 3 2 3 2 .................................................................................................................................................................................. I .................................c i Class A Optional Wiring E ....................................................................................................................................................................................... ....................................................................., Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA 13�KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev C subject to change without notice. For more information,contact Silent Knight ©2011 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com INTELLIKNIGHT •- SILENT B200SR KNIGHT by Honeywell Intelligent Sounder Base The B200SR sounder base sets a new standard for performance, installation ease, and aesthetics. It offers maximum flexibility in instal lation,configuration, and operation to meet or exceed UL 268 and UL 464 requirements. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description B200SR The B200SR Series sounder bases set a new standard for performance, installation, and aesthetics. The B200SR is designed for new and existing dwelling unit applications. It offers maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. r The B200SR is fully compatible with existing B501 BH-Series sounder base installations. The device enables users to �_�� select one of two 13501-supported tones (ANSI Temporal 3 or Continuous) by removing a jumper. With its attractive aesthetics, the B200SR is ideal for B200SR applications where appearance is critical. For example, the sounder base employs a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface- mount boxes. In addition, the mounting plate enables pre- Compatibility wiring of all connections to speed and simplify installation. The B200SR is compatible with the following The housing then mates with the mounting plate and is SK-series detectors: locked in position with two retaining screws, which are • SK-Photo Photoelectric Smoke Detector and covered by the installed sensor head for added tamper SK--Photo-T Photoelectric Smoke Detector resistance with Thermal Features: • SK-Acclimate Multicriteria Photoelectric • Tone selection via an onboard jumper Smoke Detector • UL 268 and UL 464 compliant • SK-Ion Ionization Smoke Detector • Pre-wire mounting plate fits various junction box sizes • Fully compatible with existing B501 BH-Series sounder base SK-Heat Fixed Temperature Thermal Detector, installations SK -Heat-ROR Rate-of-Rise Detector with • Mechanical locking feature prevents the removal of the Thermal, and SK-Heat-HT Fixed High attached sensor head Temperature Thermal Detector Installation The B200SR is compatible with the following The B200SR can be mounted directly into a 4" square by at IntelliKnight FACP's: least 1.5" —2.1" deep electrical box, using the supplied 5700 mounting kit. 5808 5820XL INTELLIKNIGHT ACCESSORY Model B200SR Intelligent Sounder Base INTELLIGENT MONITOR MODULE N CLASS A OPTIONAL WIRING SLC _________________________________- / ____ _____ i+a AiC Our •;j + OPTIONAL SOUNDER INTERCONNECT` _ _ —— i'/ CaenpatlAe FRCP t UL LIST S© S EOL HEASTON r x 6]k I � (EOLROt OR EQUIVALENT) ENT ) (APOWER FINSf SECOND LASE SOl1NOEA SOUNDER SOLINOE0. RASE BASE BASE (-a POWEn M USIF02" Pow91 SULLY `GROUPING OF MODEL B200SR SOUNDER BASES Specifications Physical Height: 2.0" (5.08 cm) less sensor Width: 6.875" (17.46 cm) Shipping Weight: 0.50 lb. (227 gm) Electrical External Supply Voltage 16 to 33 VDC (VFWR) External Supply Standby Current 500 pA maximum Alarm Current 35 mA maximum SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 pA maximum Environmental Operating Temperature: 32°F— 120°F (0°C—49°C) Humidity: 10% —93% non-condensing Sound Output Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone) Ordering Information B200SR Intelligent Sounder Base SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350267 Rev A subject to change without notice. For more information, contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com SYSTEM _ �4 SENSOR" � C01 224T Carbon Monoxide Detector with RealTest"Technology The System Sensor CO 7224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features With RealTest"technology,the CO gas sensing cell of the •RealTest-technology allows installer to test detector with CO gas C01 224T CO detector can be tested using a carbon monoxide gas agent.Simply hold the test button for two seconds.After the alarm Full compliance with UL 2075 cycle(temp 4)the green LED will flash about once per second, •A code required trouble relay indicating that the detector is ready to accept CO for testing. •Wiring supervision with SEMS terminals Spray a small amount of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating •A six year end-of-life timer successful gas entry. 12/24 VDC •A current draw of 20mA in standby and 40mA in alarm If dangerous amounts of carbon monoxide is detected,the COI 224T detector will alert residents by sounding and flashing a temp-4 signal Versatile mounting for wall and ceiling alarm.Protection is guaranteed 24/7 by a central station,regardless Electrochemical sensing technology of whether residents are away from home,sleeping or already suffering from the effects of CO. This specific device is designed for system operation.The detector is fully listed to UL 2075.It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The COI 224T detector offers a low current draw,allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01 224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24VDC detector. UL LISTED 2075 C01 224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number C01 224T,listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication,which blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length:5.1 in,Width: 3.3 in,Height:1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Normal(standby) Blink 1 per minute — — Alarm Blink in temp 4 pattern Sound in temp 4 pattern RealTest'Feature: The System Sensor C01 224T carbon monoxide detector with RealTest"can evaluate the functionality of the CO sensing cell using canned test agent. r L L rZONE Cad?CARBON MONOXIDE I L V Push and hold the Test/Hush button for Spray canned CO agent into the detector. Verify CO sensing at the control panel.The two seconds to enter RealTest mode.The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20-60 seconds. indicate RealTest mode has started. NOTE:Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for 5 minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End-of--life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel.This will indicate that it is time to replace the detector.An electrochemical carbon monoxide detector lifespan is approximately six years,and the detector must be replaced by the date marked on the inside of the product. Ordering Information Part No. Description C01 224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest-Technology l`�� 1 SYSTEM 02 change wit Sensor. `` r r/ 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice,Visit rystemsensoccom for SENSOR` Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat-0437-000.8/08.estversionofthlsda[asheet. A05-0437-000.8/08•#7953 INTELLIKNIGHT ACCESSORY SILENT SK-Minimon KNIGHT by Honeywell Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. �,� The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. Electrical The SK-Minimon is compatible with Features Standby Current: 400 uA max @ the following IntelliKnight Systems: • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5808 (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5700 5600 (Rev 2.0 or higher) • Small and lightweight size allows Physical SK-FFT for flexible mounting options Dimensions: • Rotary address switches for fast 2.75" W x 1.3" H x 0.5" D installation Weight: 1.2 oz (37 g) Approvals • UL listed Environmental UL approved Operating Temperature: CSFM 32°F— 120°F (0°C—49°C) FM Approved Humidity: 10% —93% non-condensing INTELLIKNIGHT O. SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The device shall be capable of Styles A and B supervised wiring to the load device. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. IN OUT F�.; + 1501 ADDRESS 0 ' 14 2 0 J2 13 3 Compatible FACP 11 It• IJ q ,i 4 10, 7.B 5 LOOP 8 65 TENS ONES + + - W m o 0 0 Other Devices Wiring the SK-Minimon SILENT This document is not intended to be used for installation purposes.We MADE IN AMERICA KNIGHT try to keep our product information up-to-date and accurate.We cannot 13", cover all specific applications or anticipate all requirements.All FORM#350133 Rev C specifications are subject to change without notice. For more information, by Honeywell contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 ©2011 Honeywell International Inc Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com