Loading...
HomeMy WebLinkAboutA13-0018 specs � ` , � � / � Commercial Specialists of Western Colorado, LLC VILLA VALHALLA Fire Alarm System Manufacturers Data Sheet • NFS2-3030- LARGE CAPACITY FIRE CONTROL PANEL • AMPS-24- NFS2-3030 POWER SUPPLY • L CM-320-L OOP CARD • UDACT-2- UNIVERSAL DIGITAL ALARM COMMUNICATOR • ACPS-610-ADDRESSABLE REMOTE POWER SUPPLY • BATT SERIES - BATTERIES • LCD-160- REMOTE ANNUNCIATOR • FAPT-851 -ADDRESSABLE SMOKE DETECTOR • FCO-851 -ADDRESSABLE COMBINATION- SMOKE, HEAT AND CO DETECTOR • FST-851 -ADDRESSABLE THERMAL DETECTOR • 8210LP/8200S -DETECTOR BA SES • FRM-1 -ADDRESSABLE CONTROL AND RELAYMODULES • FMM-1 /FDM-1 -ADDRESSABLE MONITOR MODULES • NBG-12LX-ADDRESSABLE MANUAL PULL STATION • PC2W/SCW/P2W- CEILING AND WALL MOUNT HORN STROBES AND STROBES • IF2-128- 128 POINT TERMINAL CABINET 210 Marmot Lane Unit 85—PO Box 3913 Eagle, Co 81631 Phone:970.328.1951 Fax:970.328.1956 .� �� .-: �+I��e s�pp�rt ar�d er��c��r�g�e ��C�T c�r��f��c��r . 210 Marmot Lane Unit 85—PO Box 3913 Eagle, Co 81631 Phone:970.328.1951 Fax:970.328.1956 DN-7070:1•A-10 N FS2-3030 (� N OT 1 F 1 E R° Intelligent Addressable � Fire Alarm System by H o n eywe I I General The NFS2-3030 is an intelligent Fire Alarm Control Panel designed for medium-to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these applications.The � NFS2-3030 is part of the ONYXOO Series of products from NOTIFIER.The NFS2-3030 is ideal for virtually any application . because it features a modular design that is configured per � - '�r project requirements. With one to ten Signaling Line Circuits , (SLCs), the NFS2-3030 supports up to 3,180 intelligent - — � :�t-��>�;:>. addressable devices. -- = __;� Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display(LCD) presents vital information to operators concerning a fire situa- _ : tion,fire progression,and evacuation details. -- - --> A host of other options are available, including single-or multi- channel voice; firefighters telephone; LED, LCD, or PC-based graphic annunciators; fire or integration networking; advanced �o�o�o�9.;P9 detection products for challenging environments, and many additional options. NFS2-3030s, DVC audio option at right Features • Certified for seismic applications when used with the appro- • Autoprogramming and Walk Test reports. priate seismic mounting kit. • Multiple central station communication options: • One to ten isolated intelligent Signaling Line Circuits (SLC) —Standard UDACT Style 4,6 or 7. —Internet • Up to 159 detectors and 159 modules per SLC,318 devices —InterneUGSM per loop/3,180 per FACP or network node.Detectors can be Positive Alarm Sequence(PAS) Presignal. any mix of ion, photo, laser photo, thermal, or multi-sensor � detectors; modules can be addressable pull stations, nor- • Silence Inhibit and Auto Silence timer options. mally open contact devices,two-wire smoke, notification,or • Field-programmable on panel or on PC, with VeriFire Tools relay modules. program,also check,compare. • Large 640-character LCD backlit display(16 lines x 40 char- • Non-alarm points for lower priority functions. acters)or display-less(a node on a network). • Remote ACK/Signal Silence/System Reset/Drill via monitor • Network options: modules. —High-speed network for up to 200 nodes (NFS2-3030, • Up to 1000 powerful Boolean logic equations. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, . Supports SCS Series smoke control system in both HVAC ONYXWorks, NFS-3030, NFS-640, and NCA). or FSCS modes. —Standard network for up to 103 nodes (NFS2-3030, . FM6320 approved Gas Detection System with FMM-4-20 NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, module and any FM listed gas detector. ONYXWorks, NCS, NFS-3030, NFS-640, NCA,AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes ' EIA-232 printer port. when DVC is used in network paging. • EIA-485 annunciator port. • Built-in Alarm,Trouble, Security, and Supervisory relays. 640-CHARACTER DISPLAY FEATURES • VeriFireO Tools online/offline program option. • Backlit,640-character display. • Application code is saved in Flash memory. • Program keypad:full QWERTY keypad. • With built-in Degraded Mode operation,the system is capa- . Up to nine users, each with a password and selectable ble of general alarm if a fire alarm condition is present even access levels. if the CPU fails. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- • Weekly Occupancy Schedules allow changing sensitivity by • rity; Supervisory; System Trouble; Other Event; Signals time of day and day of week. Silenced; Point Disabled;CPU Failure; Controls Active. • EIA-485 annunciators, including custom graphics. . Membrane Switch Controls: Acknowledge; Signal • History file with 4000-event capacity in nonvolatile memory, Silence; Drill;System Reset; Lamp Test. plus separate 1000-event alarm-only file. • LCD Display: 640 characters (16 x 40) with long-life LED • Advanced history filters allow sorting by event, time, date, backlight. or address. • Alarm Verification selection per point,with tally. DN-7070:1•08/09/2012—Page 1 of 8 FLASHSCANT"" INTELLIGENT FEATURES FSL-751 VIEWO (VERY INTELLIGENT EARLY WARN- • Poll up to 318 devices on each loop in less than two sec- ING)SMOKE DETECTION TECHNOLOGY onds. • Revolutionary spot laser design. • Activate up to 159 outputs in less than five seconds. • Advanced ONYX intelligent sensing algorithms differentiate • Multicolor LEDs blink device address during Walk Test. between smoke and non-smoke signals (U.S. Patent • Fully digital, high-precision protocol (U.S. Patent 5,831,524). 5,539,389). • Addressable operation pinpoints the fire location. • Manual sensitivity adjustment—nine levels. • No moving parts to fail or filters to change. • Pre-alarm ONYX intelligent sensing—nine levels. • Early warning performance comparable to the best aspira- • Sensitivity levels: tion systems at a fraction of the lifetime cost. –lon–0.5 to 2.5%/foot obscuration. FAPT 851 ACCLIMATE PLUST"'LOW-PROFILE INTELLI- –Photo–0.5 to 2.35%/foot obscuration. GENT MULTI-SENSOR –Laser(VIEWO)–0.02 to 2.0%/foot obscuration. • Detector automatically adjusts sensitivity levels without –Acclimate PIusT"'–0.5 to 4.0%/foot obscuration. operator intervention or programming. Sensitivity increases –IntelliQuad–1.0 to 4.0%/foot obscuration. with heat. –IntelliQuadT"'PLUS–1.0 to 4.0%/foot obscuration • Microprocessor-based technology; combination photo and Drift compensation (U.S. Patent 5,764,142). thermal technology. • Multi-detector algorithm involves nearby detectors in alarm ' Low-temperature signal at 40°F±5°F(4.44°C±2.77°C). • decision (U.S. Patent 5,627,515). FSC-851 INTELLIQUAD • Automatic detector sensitivity testing(NFPA-72 compliant). ADVANCED MULTI-CRITERIA DETECTOR • Maintenance alert(two levels). • Detects all four major elements of a fire (smoke, heat, CO, • Self-optimizing pre-alarm. and flame). • Programmable activation of sounder/relay bases during • Automatic drift compensation of smoke sensor and CO cell. alarm or pre-alarm. • High nuisance-alarm immunity. • Read Status displays the level of detector cleanliness. • Six sensitivity levels. Sample System Options SLC Inte/ligent Loop 1 � --------� � �� �� _ DEVICES_ � ° ° �0������� � --------- FAPT-851 °�� �r o�°°°e FSL-751 NBG-12LX FMM-1 FRM-1 XP6/101/O Up to 32 LCD-160 FSP-851 Modules LCD2-80 Remote ...etC. + Displays Relay Contact EIA-485 EIA-485 3072 annunciator/control points fi � � ��s���� - - . . . c CPU2-3030D I display or � � �� �� � CPU2-3030ND [ �. � �. � � ACM-SR .ACM/AEM-24AT • LDM-32 0 Relay Control LED Annunciator Custom Graphics �������� Optional 2048-point UDACT Dual phone lines to Central Station I3 � � I NFS2-3030 ElA-232 p � Shown in CAB-C4 with display � pRN Series DVC audio in CA-1 in second tier Printer NOTE: CPU2-3030 firmware version 14.0(and higher)can support LCD-160 on the RDP port,or LCD2-80/LCD-80 in terminal mode, but not both at the same time. Page 2 of 8—DN-7070:1•08/09/2012 FCO-851 INTELLIGIUADT"'PLUS Maintenance Warnings. When the drift compensation per- ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR formed for a detector reaches a certain level, the performance Detects all four major elements of a fire. of the detector may be compromised, and special warnings � are given. There are three warning levels: (1) Low Chamber • Separate signal for life-safety CO detection. value; (2) Maintenance Alert, indicative of dust accumulation • Optional addressable sounder base for Temp-3 (fire) or that is near but below the allowed limit; (3) Maintenance Temp-4(CO)tone. Urgent,indicative of dust accumulation above the allowed limit. • Automatic drift compensation of smoke sensor and CO cell. Sensitivity Adjust. Nine sensitivity levels are provided for • High nuisance-alarm immunity. alarm detection. These levels can be set manually, or can • Six sensitivity levels. change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- FMM-4-20 GAS DETECTION MODULE mined levels of alarm. Pre-alarm operation can be latching or • Interface to industry-standard linear scale 4-20 mA sensors. self-restoring,and can be used to activate special control func- • Five programmable thresholds. tions. • FM Approved, Class 6320 (Stationary Gas Sensors/Detec- Self-Optimizing Pre-Alarm. Each detector may be set for tors). "Self-Optimizing"pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog RELEASING FEATURES readings over a long period of time, and setting the pre-alarm • Ten independent hazards. level just above these normal peaks. • Sophisticated cross-zone(three options). Cooperating Multi-Detector Sensing. A patented feature of • Delay timer and Discharge timers(adjustable). ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or • Abort(four options). pre-alarm decisions.Without statistical sacrifice in the ability to VOICE AND TELEPHONE FEATURES resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. • Up to eight channels of digital audio. • 35 watt,50 watt,75 watt,and 100/125 watt digital amplifiers Field Programming Options (DAA2/DAX series and DS series) • Solid state message generation. Autoprogram. This timesaving feature is a special software route. The FACP "learns" what devices are physically con- • Hard-wired voice control module options. nected and automatically loads them in the program with • Firefighter telephone option. default values for all parameters. Requiring less than one min- • 30-to 120-watt analog amplifiers(AA Series). ute to run, this routine allows the user to have almost immedi- • Backup tone generator and amplifier option. ate fire protection in a new installation,even if only a portion of the detectors are installed. FlashScanO Exclusive Keypad Program Edit. The NFS2-3030, like all NOTIFIER WOI'Id-Leading Detector Protocol intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while At the heart of the NFS2-3030 is a set of detection devices and continuing to provide fire protection. The architecture of the device protocol—FlashScan(U.S. Patent 5,539,389). FlashS- NFS2-3030 software is such that each point entry carries its can is an all-digital protocol that gives superior precision and own program, including control-by-event links to other points. high noise immunity. This allows the program to be entered with independent per- As well as giving quick identification of an active input device, point segments,while the NFS2-3030 simultaneously monitors this new protocol can also activate many output devices in a other(already installed) points for alarm conditions. fraction of the time required by competitive protocols.This high VeriFireO Tools speed also allows the NFS2-3030 to have the largest device VeriFireOO Tools is an offline programming and test utility that per loop capacity in the industry — 31 S points — yet every can greatly reduce installation programming time, and input and output device is sampled in less than two seconds. increase confidence in the site-specific software. It is Win- The microprocessor-based FlashScanOO detectors have bicolor dows�based and provides technologically advanced capabili- LEDs that can be coded to provide diagnostic information, ties to aid the installer. The installer may create the entire such as device address during Walk Test. program for the NFS2-3030 in the comfort of the office, test it, store a backup file,then bring it to the site and download from ONYX Intelligent Sensing a laptop into the panel. ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection Product Line Information capability. These complex algorithms require many calcula- . "Configuration Guidelines"on page 4 tions on each reading of each detector,and are made possible . ��Networking Options"on page 4 by the very high-speed microcomputer used by the NFS2- 3030. • "Auxiliary Power Supplies and Batteries"on page 4 Drift Compensation and Smoothing. Drift compensation ' "Audio Options"on page 4 allows the detector to retain its original ability to detect actual • "Compatible Devices, EIA-232 Ports"on page 5 smoke, and resist false alarms, even as dirt accumulates. It • "Compatible Devices, EIA-485 Ports"on page 5 reduces maintenance requirements by allowing the system to . °�Compatible Intelligent Devices"on page 5 automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by ' "Enclosures,Chassis,and Dress Plates"on page 6 software to remove transient noise signals, usually caused by • "Other Options"on page 6 electrical interference. DN-7070:1•08/09/2012—Page 3 of 8 CONFIGURATION GUIDELINES FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with Stand-alone and network systems require a main display. On battery charger. See DN-6927. single-CPU systems (one NFS2-3030D), the display option is BAT Series: Batteries.AMPS-24 uses two 12 volt,7 to 200 AH the CPU2-3030D. On network systems (two or more net- batteries. See DN-6933. worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as AUDIO OPTIONS follows. NOTE:See"Enclosures,Chassis,and Dress Plates"on page 6 for CPU2-3030D: NFS2-3030 Primary Display. CPU2-3030D mounting hardware. ships with keypad/display installed; includes 640-character DVC-EM: Digital Voice Command,digital audio processor with backlit LCD display, QWERTY programming and control key- message storage for up to 32 minutes of standard quality (4 pad. CPU2-3030 is a central processing unit and requires an minutes at high quality)digital audio.See DN-7045. AMPS-24(E)power supply. DVC-RPU: Digital Voice Command Remote Paging Unit for CPU2-3030ND: CPU2-3030 without display. use with DVC-EM. Includes the keypad/display. See DN- LCM-320: Loop Control Module. Adds SLCs to 3030; 3030 60726. supports up to 5 LCM-320s and 5 LEM-320s. See DN-6881. DS-DB: Digital Series Distribution Board, provides bulk ampli- LEM-320: Loop Expander Module. Expands each LCM used fication capabilities to the DVC while retaining digital audio dis- on the 3030. See DN-6881. tribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- SAMPLE SYSTEM: Four-loop NFS2-3030 with display: lation. See DN-60565. CPU2-3030D, DP-DISP, two BMP-1s, CHS-M3, two LCM- DVC-KD: Keypad for local annunciation and controls; status 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- LEDs and 24 user-programmable buttons. See DN-7045. 100, batteries. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS NETWORKING OPTIONS requires DS-XF70V step-up transformer. Digital Series Ampli- NCA-2: Network Control Annunciator, 640 characters. An fier, part of the DS-DB system. See DN-60663. alternate primary display for CPU2-3030 can be provided by DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary DVC, DS-DB distribution board,and DAX/DAA2 Series amplifi- display enables non-English languages. On network systems ers. See DN-60633. (two or more networked fire panel nodes),one network display (either NCA-2, NCS,or ONYXWorks)is required for every sys- DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- tem. On network systems,the NCA-2 connects (and requires) bly with power supply; includes chassis. See DN-60556. a standard Network Control Module or High-Speed Network DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier Control Module. Mounts in a row of FACP node or in two assembly with power supply; includes chassis.See DN-60556. annunciator positions. Mounting options include the DP-DISP, DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly ADP-4B, or in an annunciator box, such as the ABS-2D. In With power supply; includes chassis. See DN-60556. CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting.See DN-6858. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly NCM-W, NCM-F: Standard Network Communications Mod- With power supply, includes chassis. See DN-60561. ules. Wire and multi-mode fiber versions available. See DN- DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- 6861. bly with power supply, includes chassis.See DN-60561. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed network DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly communications modules that can connect to two nodes.Wire, with power supply, includes chassis. See DN-60561. single-mode fiber, multi-mode fiber, and media conversion DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- models are available. See DN-60454. bly with power supply, includes chassis.See DN-60561. RPT-W, RPT F, RPT WF: Standard-network repeater board TELH-1: Firefighter's Telephone Handset for use with the DVC with wire connection (RPT-W), fiber connection (RPT-F), or When mounted in the CA-2 chassis. See DN-7045. allowing a change in media type between wire and fiber(RPT- WF). Not used with high-speed networks.See DN-6971. CMIC-1: Microphone us gved with DVC/DVC-EM. Included ONYXWorks: UL-listed graphics PC workstation,ONYXWorks `Nith CA-2 chassis assembly. See DN-7045. GUI software, and computer hardware. See DN-7048 for spe- RM-1/RM-1SA: Remote microphone assemblies, mount on cific part numbers. ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) NFN-GW-EM,NFN-GW-EM-3: NFN Gateway, embedded.See stand-alone cabinets.See DN-6728. DN-60499. FTM-1: Firephone Control Module connects a remote fire- fighter telephone to a centralized telephone console. Reports AUXILIARY POWER SUPPLIES AND BATTERIES status to panel. Wiring to jacks and handsets is supervised. AMPS-24(E): One required for each NFS2-3030.Addressable See DN-6989. power supply and battery charger with two 24 VDC outputs. AA-30: Audio Amplifier, 30 watts. Switch-mode power. Addressable by any FlashScanOO or CLIP mode FACP. Includes amplifier and audio input supervision, backup input, Charges 7 to 200 AH batteries.Occupies up to four addresses and automatic switchover, power supply, cables. See DN- on an SLC, depending on configuration. Primary input power 3224. for panel. See DN-6883. AA-120JAA-100: Audio Amplifier provides up to 120 watts of APS2-6R:Auxiliary Power Supply. Provides up to 6.0 amperes 25 Vrms audio power.The amplifier contains an integral chas- of power for peripheral devices. Includes battery input and sis for mounting to a CAB-B4,-C4,or-D4 backbox(consumes transfer relay, and overcurrent protection. Mounts on two of one row). Switch-mode power. Includes audio input and ampli- four positions on a CHS-4L or CHS-4 chassis. See DN-5952. fied output supervision, backup input, and automatic switcho- ACPS-610: 6.0 A or 10 A addressable charging power supply. ver to backup tone. Order the AA-100 for 70.7 Vrms systems See DN-60244. and 100 watts of power. See DN-3224. Page 4 of 8—DN-7070:1•08/09/2012 DAA Series Digital Audio Ampiifiers: Legacy DAA Series BEAMMRK: Multi-mount kit, FSB-200(S) below. See DN- amplifiers are compatible with DVC systems running SR4.0. 6985. For specific information on DAA-50 series amplifiers, refer to BEAMSMK: Surface-mount kit, FSB-200(S) below. See DN- DN-7046. For information on DAA-7525 Series, refer to DN- 6985. 60257. FSB-200: Intelligent beam smoke detector. See DN-6985. COMPATIBLE DEVICES, EIA-232 PORTS FSB-200S: Intelligent beam smoke detector with integral sen- PRN-6: 80-column printer. See DN-6956. sitivity test.See DN-6985. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria See DN-3260. Detector.See DN-60412. DPI-232: Direct Panel Interface, specialized modem for FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- extending serial data links to remotely located FACPs and/or ria Fire/CO Detector. See DN-60689. peripherals. See DN-6870. FSI-851: Low-profile FlashScan ionization detector. See DN- COMPATIBLE DEVICES, EIA-485 PORTS 6985. ACM-24AT:ONYXOO Series ACS annunciator-up to 96 points FSP-851: Low-profile FlashScan photoelectric detector. See of annunciation with Alarm or Active LED, Trouble LED, and DN-6935. switch per circuit. Active/Alarm LEDs can be programmed (by FSP-851 R: Low-profile intelligent photoelectric sensor, remote powered-up switch selection) by point to be red, green, or yel- test capable. For use with DNR(W). See DN-6935. low;the Trouble LED is always yellow.See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT; FSP-851T: Low-profile FlashScan photoelectric detector with expands the ACM-24AT to 48,72,or 96 pointsSee DN-6862. 135°F(57°C)thermal.See DN-6935. ACM-48A: ONYXOO Series ACS annunciator-up to 96 points FST-851: FlashScan thermal detector 135°F (57°C). See DN- of annunciation with Alarm or Active LED per circuit. Active/ 6936. Alarm LEDs can be programmed(by powered-up switch selec- FST 851 R: FlashScan thermal detector 135°F (57°C) with tion) in groups of 24 to be red,green,or yellow. Expandable to rate-of-rise.See DN-6936. 96 points with one AEM-48A. See DN-6862. FST-851H: FlashScan 190°F(88°C) high-temperature thermal AEM-48A: Same LED capabilities as ACM-48A; expands the detector. See DN-6936. ACM-48A to 96 points. See DN-6862. FAPT 851: FlashScan Acclimate PIusT"' low-profile multi-sen- ACM-8R: Remote Relay Module with eight Form-C contacts. sor detector. See DN-6937. Can be located up to 6,000 ft. (1828.8 m) from panel on four FSL-751: FlashScan VIEWOO laser photo detector. See DN- wires. See DN-3558. 6886. LCD-160: Liquid Crystal Display annunciator, 160-character DNR: InnovairFlex low-flow non-relay duct-detector housing backlit. Can store character sets for multiple languages. Sup- (order FSP-851 separately). Replaces FSD-751 PL/FSD- ports Canadian requirements. See DN-6940 751 RPL. See DN-60429. LCD-80: ACS mode. 80-character, backlit LCD display. DNRW: Same as above with NEMA-4 rating, watertight. See Mounts up to 6,000 ft. (1828.5 m) from panel. Up to 32 per DN-60429. FACP.See DN-3198. B224RB: Low-profile relay base. See DN-60054. LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per B224BI: Isolator base for low-profile detectors. See DN- FACP.See LCD2-80(DN-60548). 60054. SCS Series: Smoke control station; eight (expandable to 16) B210LP: Low-profile base. Standard U.S. style. Replaces circuits. See DN-4818. B710LP. See DN-60054. TM-4: Transmitter Module. Includes three reverse-polarity cir- B501: European-style,4" (10.16 cm)base. See DN-60054. cuits and one municipal box circuit. Mounts in panel module B200S: Intelligent programmable sounder base, capable of position (as in single-address mode applications) or in CHS- producing a variety of tone patterns including ANSI Temporal M3 position. See DN-6860. 3.Compatible with sychronization protocol. See DN-60054. UDACT: Universal Digital Alarm Communicator Transmitter, B200SR: Sounder base, Temporal 3 or Continuous tone. See 636 channel See DN-4867. DN-60054. UDACT 2: Universal Digital Alarm Communicator Transmitter, FMM-1: FlashScan monitor module.See DN-6720. 636 channel. See DN-60686. FDM-1: FlashScan dual monitor module. See DN-6720. UZC-256: Programmable Universal Zone Coder provides pos- FZM-1: FlashScan two-wire detector monitor module.See DN- itive non-interfering successive zone coding. Microprocessor- 6720. controlled, field-programmable from IBMOO-compatible PCs (requires optional programming kit). Mounts on a CHS-4 FMM-101: FlashScan miniature monitor module. See DN- series chassis within NFS2-3030. 6720. COMPATIBLE INTELLIGENT DEVICES FMM-4-20: FlashScan 4-20 mA protocol monitor module. See D N-60411. BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(S) below. See DN-6985. FCM-1: FlashScan NAC control module.See DN-6724. BEAMHKR: Heating kit for use with the reflector of FSB- FCM-I-REL: FlashScan releasing control module. See DN- 200(S) below. See DN-6985. 60390. BEAMLRK: Long-range accessory kit, FSB-200(S) below. FRM-1: FlashScan relay module.See DN-6724. See DN-6985. DN-7070:1•08/09/2012-Page 5 of 8 FDRM-1: FlashScan dual monitor/dual relay module. See DN- DPA-2: Dress Panel used with the CA-2 chassis assembly. 60709. DPA-1 A4: Dress panel, used with the CA-1 chassis when the NBG-12LX: Manual pull station,addressable. See DN-6726. CMIC-1 is not used. Provides mounting options on right two ISO-X: Isolator module. See DN-2243. bays for two ACS annunciators, or for blank plates. See DN- 7045. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- XP6-MA: FlashScan six-zone interface module; connects tors. intelligent alarm system to two-wire conventional detection zone. See DN-6925. BMP-1: Blank module for unused module positions. XP6-R: FlashScan six-relay (Form-C) control module. See DP-1 B: Blank dress panel. Provides dead-front panel for DN-6926. unused tiers;covers DAA2-series or AA-series amplifier. XP10-M: FlashScan ten-input monitor module. See DN-6923. BP2-4: Battery plate, required. ENCLOSURES,CHASSIS,AND DRESS PLATES CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CHS-4N: Chassis for mounting up to four APS-6Rs. CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered seperately; requires BP2-4 CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. battery plate. A trim ring option is available for semi-flush Mounts up to six modules in any CAB-4 series row. mounting. See DN-6857. BB-100: Backbox for batteries and power supplies. The BB- EQ Series Cabinets: EQ series cabinets will house amplifiers, 100 is used to mount up to two 100-AH batteries and power power supplies, battery chargers and control modules. EQ supply, if needed. 30" (76.20 cm)wide x 25" (63.50 cm) high x cabinets are available in three sizes, "B"through"D". See DN- 7.5" (19.05 cm)deep;depth includes door. 60229. BB-200: Backbox for batteries and power supplies. Holds the CHS-M3: Mounting chassis for CPU2-3030. One required for AMPS-24(E) power supply when AMPS-24(E) is used as a each CPU2-3030D/3030ND. charger for 200 AH batteries. Holds up to four 100 AH batter- CA-2: Chassis for CPU when DVC is used with firefighter's ies and power supply. 30" (7620 cm) wide x 36" (91.44 cm) telephone. Mounts in the top two rows of a CAB-4 series high x 7.5" (19.05 cm)deep;depth includes door. enclosure. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to DP-DISP: Dress panel for top row in cabinet with CPU2- two 55-AH batteries. Dimensions: Box: 24" (610 mm) wide x 3030D installed. 14" (356 mm) high x 7.75" (197 mm)deep. Door:24.125"(613 mm)wide x 14.25"(362 mm)high;door adds 0.0625"(approx. DP-1 B: Blank dress panel. Provides dead-front panel for 1.6 mm)to depth. unused tiers; covers DAA2-series or AA-series amplifier. See BB-UZC: Backbox for housing the UZC-256 for applications DN-7046. where the UZC will not fit in panel enclosure. Black; for red, CHS-BH1: Battery chassis; holds two 12.0 AH batteries. order BB-UZC-R. See DN-3404. Mounts on the left side of DAA2 chassis. See DN-7046. SEISKIT CAB: Seismic mounting kit. Required for seismic- CA-1:Chassis,occupies one tier of a CAB-4 Series enclosure. certified applications with NFS2-3030 and other equipment The left side accommodates one DVC and a DVC-KD mounted in CAB-4 Series Enclosures. Includes battery bracket (optional); and the right side houses a CMIC-1 microphone for two batteries up to 26 AH. and its well (optional).See DN-7045. SEISKIT 320/B26: Seismic mounting kit. Required for seismic- CA-2:Chassis assembly,occupies two tiers of a CAB-4 Series certified applications with BB-26. Includes battery bracket for enclosure. The left side accommodates one DVC mounted on two 26 AH batteries. a half-chassis and one NFS2-3030 or NCA-2 mounted on a SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery half-chassis. The right side houses a microphone/handset bracket for two 55 AH batteries. well.The CA-2 assembly includes CMIC-1 microphone.ADDR Series doors with two-tier visibility are available for use with SEISKIT-PS/2/4: Seismic mounting kit for the FCPS-24S6/S8 the CA-2 configuration: ADDR-B4, ADDR-C4, ADDR-D4 and CAB-PS1. Includes battery bracket for two 7 AH or 12 AH (below). batteries. ADDR-B4:Two-tier-sized door designed for use with the CA-2 OTHER OPTIONS chassis configuration. ADDR Series doors are similar to CAB- 411: Slave digital alarm communicator.See DN-6619. 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox 411 UDAC: Digital alarm communicator. See DN-6746. with the ADDR-B4.See DN-7045, DN-6857. IPDACT 2, IPDACT Internet Monitoring Module: Connects ADDR-C4:Three-tier-sized door designed for use with the CA- to primary and secondary DACT telephone output ports for 2 chassis configuration. ADDR Series doors are similar to internet communications over customer-provided ethernet CAB-4 Series "DR" doors, but a clear window space exposes connection. Requires compatible Teldat VisorALARM Central the top two tiers of the CAB-4 enclosure. Use an SBB-C4 Station Receiver.Can use DHCP or static IP. See DN-60408. backbox with the ADDR-C4.See DN-7045, DN-6857. IPCHSKIT: IP Communicator Chassis Mounting Kit. For ADDR-D4: Four-tier-sized door designed for use with the CA-2 mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 chassis configuration. ADDR Series doors are similar to CAB- series chassis. Use IPENC for external mounting applications. 4 Series "DR" doors, but a clear window space exposes the IPSPLT:Y-adaptor option allow connection of both panel dialer top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox outputs to one IPDACT-2/2UD cable input. with the ADDR-D4.See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red;for black,order IPENC-B. ured with a DVC, DVC-KD,and CMIC-1.See DN-7045. Page 6 of 8-DN-7070:1•08/09/2012 IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only,or IP primary with cellular backup.Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See DH-60695. NOTE: For other options including compatibility with retrofit equip- ment,refer to the panel's installation manual,the SLC manual,and the Device Compatibility Document. DN-7070:1•08/09/2012—Page 7 of 8 SYSTEM SPECIFICATIONS System Capacity Agency Listings and Approvals • Intelligent Signaling Line Circuits...........1 expandable to 10 These listings and approvals apply to the modules specified in • Intelligent detectors..........................................159 per loop this document. In some cases,certain modules or applications Addressable monitor/control modules..............159 per loop may not be listed by certain approval agencies, or listing may � be in process.Consult factory for latest listing status. • Programmable software zones.............................over 2000 • ACS annunciators • UL Listed: S635. per CPU2-3030.......................32 address x 64 or 96 points ' ULC Listed:S635. NOTE: The CPU2-3030 can support up to 96 annunciator ' MEA:232-06-E. address points per ACM-24/-48. • FDNY: COA#6114. • CSFM:7165-0028:0224(Commercial). Specifications • FM Approved. • Primary input power: • FM6320 Approved.Class 6320 for Gas Detection. —AMPS-24: 110-120 VAC, 50/60 Hz,4.5 A maximum. • City of Chicago. —AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. • City of Denver. • DC output: • PSB Corporation. —Main 24 VDC: Up to 5.0 A • CCCF listed. —Aux 24 VDC: Up to 5.0 A • Fire Services Department(Hong Kong). —5 VDC: Up to 0.15 A. NOTE: For details of DC output values,see manual 51907. Standards • Battery charger range:7 AH—200 AH. Use separate cab- The NFS2-3030 complies with the following UL Standards and inet for batteries over 26 AH. NFPA 72, IBC,and CBC Fire Alarm Systems requirements: • Ftoat Rate:27.6 V. • UL 864(Fire). • UL 1076(Burglary). Shipping Weight • LOCAL (Automatic, Manual, Waterflow and Sprinkler —CPU2-3030D:5.95 Ib(2.70 kg). Supervisory). —CPU2-3030ND:2.90 Ib(1.32 kg). • AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). Temperature and Humidity Ranges • REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory)(requires TM-4). This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH ' PROPRIETARY (Automatic, Manual, Waterflow and Sprin- (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the kler Supervisory). Not applicable for FM. useful life of the system's standby batteries and the electronic • EMERGENCY VOICE/ALARM. components may be adversely affected by extreme tempera- • OT, PSDN (Other Technologies, Packet-switched Data Net- ture ranges and humidity. Therefore, it is recommended that work). this system and its peripherals be installed in an environment . IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). with a normal room temperature of 15—27°C/60—80°F. • CBC 2007(Seismic). IntelliQuadT"'and NOTI•FIRE•NETTM are all trademarks; and Acclimate(� PIusT"",FlashScan�,NOTIFIERO,ONYXO,VeriFireC�,and VIEWO are all registered trademarks of Honeywell International Inc. �02012 by Ho�eywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 8 of 8—DN-7070:1•08/09/2012 DN-6883:B AMPS-24/E � N OT 1 F 1 E R° Power Supply � for the NFS-3030, NFS2-3030 and NCA-2 by H o n eywe I I General NOTIFIER's AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan� or CLIP (Classic Loop Interface Protocol) �a����m , mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel �r�� ...__.:s. � � (FACP). It can also be used as the primary power supply for � „ ��A�° :� �Qxazaaoous � the NCA-2 Network Control Annunciator. WaR.+� "°�T"�E$ q, LOFEREMIbOUZ¢E54FMM A7 � .�`� 0 U pSCOFNEG c[SOF G f C E +' •/� Features . ��_;, � � • Addressable by NFS-3030/NFS2-3030 FACP. ����t�'i�'d�'" J��'�r�°`. •� • Selectable charging current charges 7 AH to 200 AH batter- „��, ,. � ies. `,�'"``�.. /t�- � '` � � � � � � • Isolated Signaling Line Circuit(SLC)interface. ' w � ` . ` � �} • Trouble bus input for use with normally-open dry contacts or �; . � � � � � � � +� open-collector circuit. .��,} � �� ' � � � fl • USB Type B connector for programming installation param- , � �' '' � � � � � eters. � � ��• _.�����,����"� • Brownout detection. -" � , .< ' , i�,.... ,� • Battery/battery charger supervision. - =�y� ��!�••� • Secondary Power Auxiliary Outputs:24V @ 0.5A and 5V @ �a�y�y�,,,_ �tl ��° `-°_ • . `` � 0.15A. • AC loss detection and AC loss delay reporting. • Mounts in a CAB-4 Series enclosure, EQ Cabinet Series enclosure, BB-25, BB-100, or BB-2oo Battery BackboX. p9ency Listings and Approvals Specifications These listings and approvals apply to the AMPS-24/E power supply. In some cases, certain modules may not be listed by • Primary(AC) power: certain approval agencies, or listing may be in process. Con- AMPS24: 110-120 VAC 50/60 Hz input, 5 A maximum; sult factory for latest listing status. AMPS24E: 220-240 VAC 50/60 Hz input,2.5 A maximum. • MAIN 24V Output - filtered power-limited power. Refer to ' UL: S635 table for configuration/current information. • ULC: CS118 • City of Chicago Charger Setting/ Main 24V(TB 1 on "ToWI AUX 24V(TB3 on Main Battery Size Main Control Unit) Control Unit with TB2 on CPS- • City of Denver Max.Current 24)Max.Current • MEA:345-02-E 1A/7-26AH Bat- teries 5A 3,4 • CSFM: 7165-0028:224 2A/12-60AH Bat- 5A 3A • FM:Approved teries • FDNY:#6026 SA/55-200AH Configuration 1 SA OA Configuration 2 3A 1A Product Line Information Disabled SA SA AMPS-24:Addressable power supply/battery charger �Maximum current for all AUX 24 volt outputs.Note that TB2 on CPS-24 is umaeacoo.5a. AMPS-24E:Same as AMPS-24:220-240VAC operation • AUX 24V - provides filtered power-limited power for addi- tional components. Refer to table above for configuration/ current information. • Secondary power(battery)charging circuit: Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries. Selectable charging current: 1.0 A,2.0 A or 5.0 A. • Secondary power auxiliary outputs. • Wire sizes: 10 AWG(5.26 mm2)to 22 AWG (0.326 mmz). • Battery fuse(F2): 15 A,fast-acting. • Shipping Weight: 4.25 Ib DN-6883:B•10/15/09—Page 1 of 2 FlashScanO is a registered trademark of Honeywell International Inc. �02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6883:B•10/15/09 DN-6881:A1 •A-35 LCM-320 and LEM-320 (1 N OT 1 F 1 E R� Loop Control and Expander Modules � by Honeywell General The LCM-320 Loop Control Module and the LEM-320 Loop 4 , _ Expander Module provide NOTIFIER's ONYXO Series of Fire � ,3 . — � -�; Alarm Control Panels (FACPs) with Signaling Line Circuits ��r � �,+ (SLCs).The ONYXO Series NFS-640/NFS2-640 supports one �� - • � .� � � _ LEM-320;the NFS-3030/NFS2-3030 supports up to five LCM- r�_ �c�� ;�A"�`�t�: "! ���' �"• � �. 3� 320s and five LEM-320s. The LEM-320 module is used to j f` r+ � -��, I� �-�� � i� � � �� �� � ���� ;�-� ;�f��o.� .. expand the NFS-640/NFS2-640 to a second loop, and to �� _ � _ ", � ��� � �a��-�� � expand each LCM-320 used on the NFS-3030/NFS2-3030— - � E� , .���� -:�� each NFS-3030/NFS2-3030 LCM-320 supports an expansion I � '- '� ��� ���� �" ._�� � LEM-320. 'I ��'� 1� � ���-� � ���,���� � ��- �''- a� , �= � ��;- � �� � � � �� �a ���� s � t ' � y s� �. s� Features o �� `°�`�-��' ��'�� � ���-� ���q� ;� ;� =t - I �- � _ � �� ,� _ � ���sj, � � '�` ,: • Up to 12,500 feet(3,810 m)on a Class B(Style 4)SLC loop , �,�,� � _ ����ti � ��� 3� (twisted-unshielded). � � ��<„� , - � ; 'r� ,� � • Built-in degraded mode increases survivability. �—` ' " �f 4 � � l�`<� `� ,� : • Ver sim le installation— lu m st le. ° ' ��'�E'°�'��"'-��x � ' �'��� � 'i � : Y p P 9- Y ��!�;�� � �:' �;' �� p�, j • Permits multiple loops in small enclosure. � :. �-°P� . ��r "m '� -'`�,�,,� Specifications Loop Control Loop Expander Module Module Voltage:24 VDC nominal,27.6 VDC maximum. Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2) twisted-pair wire is 12,500 feet Product Line Information (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2)to 18 AWG (0.78 mmz): LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- -Distance with 12 AWG: 12,500 ft(3,810 m). 320s and five LEM-320s. -Distance with 14 AWG:8,000 ft(2,438 m). LEM-320: Loop Expander Module. Expands each LCM used -Distance with 16 AWG:4,875 ft(1,486 m). on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to -Distance with 18 AWG:3,225 ft(983 m). two loops. -50 ohms maximum per length of Style 6&7 loops. -50 ohms maximum per branch for Style 4 loop. AgenCy LIStlitgS a11C1 AppPOVa1S Maximum current: for LCM-320: 130 mA;for LEM-320: 100 The listings and approvals below apply to the basic LCM-320 mA;for single SLC loop:400 mA maximum. and LEM-320. In some cases, certain modules may not be NOTE:Maximum short circuit—loop will shut down until short-cir- listed by certain approval agencies, or listing may be in pro- cuit condition is corrected. cess. Consult factory for latest listing status. Maximum resistance: 50 ohms (supervised and power- ' UL: S635 limited). • ULC: S635/CS118 Temperature and humidity ranges: This system meets • FM Approved NFPA requirements for operation at 0-49°C/32- 120°F and • CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 at a relative humidity 93%±2% RH (noncondensing) at 32°C with NFS-3030/NFS2-3030). 7165-0028:214, 7170- ± 2°C (90°F ± 3°F). However, the useful life of the system's 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- standby batteries and the electronic components may be 0028:244(LEM-320 with NFS2-640). adversely affected by extreme temperature ranges and humid- . FDNY:COA#6025(LEM-320 with NFS2-640) ity. Therefore, it is recommended that this system and its . FDNY:COA#6026(LCM-320/LEM-320 with NFS2-3030) peripherals be installed in an environment with a normal room temperature of 15-27°C/60-80°F. • City of Denver • Hong Kong DN-6881:A1•06/05/2009—Page 1 of 2 FLASHSCANO and NOTIFIERO are registered trademarks of Honeywell International Inc. �02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6881:A1 •06/O5/2009 D N-60686:A1 . � u�a T 2 NoTI FI E R° Universal Digital Alarm � Communicator Transmitter by H o n eywe I I General _ _ - _ , , The Universal Digital Alarm Communicator Transmitter(UDACT- � �i' � 2) is designed for use on Notifier Fire Alarm Control Panels and �� �' � �' on the NCA-2 Network Control Annunciator.When used in con- � � -- � junction with the NCA-2 network control annunciator, the '� �" �9 `,. .�r II UDACT-2 can report the status of all control panels on , � � ;� ."�'� NOTI•FIRE•NETT"'.The UDACT-2 transmits system status to UL , � F '" ��� listed Central Station Receivers via the public switched tele- �* � „LL1� � ,,� � phone network.The UDACT-2 can be installed in the panel cab- �,,� ��' inet or remotely in a separate enclosure. �r�� v�� � y � ��„ r:�. r_,�s. NOTE: The UDACT-2 can also be used with le gac y panels. �„�� Y�T� �i�` Please refer to the UDACT-2 manual for more information. 3;� � �("�� `���� �;�: 'j` ,'`'' . �,` The UDACT-2 upload/download programming and firmware �==:--,;� T��'�a w,�� updates are accomplished with VeriFire Tools. Refer to the Pro- ,t� ��_L'�`* gramming Section for further details. _ �' �,;.�+.�� r_. n- '{ �._�`i� A. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, � +- '� Supervisory, Bell Trouble, Low Battery, and AC Fail. The � `���' �-- �`� � UDACT-2 is capable of transmitting all of the zone and point sta- - tus associated with each panel. �' t. � �' - When the UDACT-2 is used with the NFS-3030, NFS2-3030, �+ ,,: �•i � and NCA-2 it is capable of reporting up to 2,040 points. Report- � }' '� ing may be in the form of points or zones(refer to the UDACT-2 `% manual for specific reporting parameters). Points transmitted � may be programmed for a variety of types, including fire, water- flow,supervisory,etc. UDACT-2 NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart ' Open Collector relay driver for Total Communications Failure on page 2 for compatible receivers. or UDACT-2 trouble. Features • Real-time clock. • Extensive transient protection. • Programmable with VeriFire Tools version 6.60 or higher, . EIA-485 interface to host panel. allowing the UDACT-2 programming to be uploaded/down- loaded and saved. PPOgP1111111111g • Maximum of 14 point trouble messages transmitted per hour. The UDACT-2 programming is created and downloaded using • Dual phone lines with line voltage detect. VeriFire Tools. This enables the unit to be programmed prior to • Compact in size:6.75"x 4.25"(17.145 x 10.795 cm). installation, be easily modified, and saved either online or • USB port for upload/download programming. offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- • Manual Test Report function. work annunciator.The point report consists of the central station • Manual Transmission Clear function. point address,ACS point,ACS point function, panel label,panel • Mounts in a separate enclosure(ABS-8RB or UBS-1 B/R). point, type code, custom and extended label, alarm verification, • Communicates vital system status including: walktest participation, presignal,and PAS information.The zone —Independent zone fire alarm. report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label —Independent zone non-fire alarm. and panel label. This report may be sent to the Central Station —Independent zone trouble. for their records. VeriFire Tools also supports upgrading the —Independent zone supervisory. UDACT-2 operating firmware. —AC(mains) Power Loss(programmable). —Low Battery and Earth Fault. —System Off-Normal. —12 or 24 hour test signal. —Abnormal Test Signal per new UL requirements. —EIA-485 Communication Bus Failure. • Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. • Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. DN-60686:A1 •4/2/12—Page 1 of 2 Communication Formats UL Listed Receivers • Ademco Contact ID The chart below shows UL listed receivers compatible with the • 4+2 Standard UDACT-2. A check in the protocol column indicates the receiver • SIA supports that protocol. NOTE: Ademco Contact ID must be used for independent zone reporting. 4+2 Ademco Type Mode Feature Standard Contact Ademco Contact ID format - only Use Type Mode to identify Receiver 1800/2300 ID SIA reports to Central Station as: Ademco 685(1) �/ �/ • Fire Alarm •Burglary • Supervisory •24 hour Non-Burglary Ademco MX8000(2) �/ �/ �/ • Pull Station •High Temperature • Heat Detector •Low Temperature Silent Knight 9500(3) �/ �/ �/ • Waterflow •Low Water Pressure Silent Knight 9800(4) �/ �/ �/ • Duct Detector •Low Water Level • Flame Sensor •Pump Failure FBI CP220FB(5) �/ �/ �/ • Smoke Zone Osborne Hoffman 2000E(6) �/ �/ Electrical Specifications Radionics 6600(7) �/ �/ Standby current:40 mA. SurGard MLR2(8) �/ �/ Current while communicating: 75 mA. Maximum current while communicating and with open collector SurGard System III (9) �/ �/ output activated: 100 mA. SurGard MLR-2000(10) �/ Voltage: Regulated 24 volts. Range:21.2 to 28.2 volts. Agency Listings and Approvals �1)With 685-8 Line Card with Rev 4.4d software (2)With 124060V206B and 124063 Line Card Rev B In some cases, certain modules may not be listed by certain (3)With version V2.4 Receiver& 126047 Line Card Rev G approval agencies, or listing may be in process. Consult factory for latest listing status. (4)With 124077V2.00 Receiver&126047 Line Card Rev M • UUULC Listed:S635 (5)With software V3.9 • FM Approved (6)With V.7301 Receiver S/W • CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (7)With 01.01.03 Receiver S/W&Line Card 01.01.03 (NFS2-3030) (8)With software V1.86 • FDNY:COA#6085,COA#6098 (g)With sotware V1.72 Ordering Information (10)With DSP4016 and V1.6 Line Card UDACT-2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions,and mounting hardware. MCBL-7: DACT phone cord,7 ft(2.13 m)long(two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP.9.94" H x 4.63"W x 2.50" D(cm:25.248 H x 11.760 W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1 BR: Metal enclosure with solid door, Red. R-10E:SPDT Form-C relay.Contacts rated for 10 A@ 115 VAC. Connects to open collector relay driver. R-20E:DPDT Two Form-C relays.Contacts rated for 10A @ 115 VAC.Connects to open collector relay driver. NOTI•FIRE•NETT"^is a trademark and Notifiei0 is a registered trademark of FBD-1: Ferrite bead kit. Use for remote mounting only. Honeyweu internationai inc. �02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANIIFACT�RINC All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60686:A1•4/2/12 DN-60244:C3 ACPS-610(E) � NOTI FI E R° Addressable Charger/Power Supply � by Honeywell General ,� �4t i.,: 9 The ACPS-610(E) is an auxiliary power supply with a battery "� charging option and a host of special features. Selectable � � � � ; ���. . charging options allow the ACPS-610(E)to provide 6 amps of `��"- �-��-`t�-- �� - ° � A y•-` " shared power to tour outputs while charging batteries from a /�� o.,, � � i 12 to 200 AH, or 10 amps of shared power when the unit is r_;��, � H„,H� P°E}s � configured for use with an external battery charger. Four indi- ;'g�q— �_ �«. � � I vidually addressable outputs can be independently configured ��� '� I for auxiliary power or Notification Appliance Circuits (NAC). � - #°�:''�� ,. ,,. � � ' NAC outputs support notification appliance synchronization for '� � ,-���, i devices manufactured by System SensorOO, Wheelock, and ��� ` -� 1 Gentex. An option to disable battery charging allows the sys- �* : T' � �+ • � � , '� •i tem designer to use the four built-in circuits to distribute � '� '� � � � � '� � 10 amps of power for general purposes, excluding NAC appli- .,(� �",�'�'��'�'',������ I i � cations. _ � ' � � �,'o • � O b 4r � The ACPS-610(E) is compatible with NOTIFIER intelligent fire , � � � � 0 � � � alarm control panels using CLIP and FlashScanOO protocoL 'E: f �`' t � �`) � � � � � � � :_:. __... � � � .Y ..�.,,- Features � � • Certified for seismic applications when used with the appro- priate seismic mounting kit. Specifications • Approved for Marine applications when used with listed compatible equipment(see DN-60688). • Primary(AC) power: • Provides 6.0 A of NAC power or 10 A of general purpose -ACPS-610: 120 VAC, 50/60 Hz input,5.0 A maximum. power. -ACPS-610E: 220/240 VAC, 50/60 Hz input, 2.5 A maxi- • Four Class B (Style Y) or four Class A (Style Z) outputs, mum. individually addressable by the FACP. • Output voltage: 24 VDC electrically regulated and power • When built-in outputs are configured for NAC operation, limited (under primary AC mains). Under secondary power, each circuit supports strobe synchronization with the follow- 20.4 to 26.4 VDC. ing manufacturers' audio/visual devices: System SensorOO • Output circuits-TB3, TB4,TB5,TB6 on Main Board: 1.5 A (SpectrAlertOO and SpectrAlert Advance Series) or Whee- maximum for any NAC output circuit. 2.5 A maximum for lock or Gentex. any Power output with battery charger disabled. • Each circuit can be software-selected for use as: a Notifica- • Secondary power (battery) charging circuit- lead-acid bat- tion Appliance Circuit,general purpose 24 VDC power,four- tery charger which will charge 12 to 200 AH batteries. Max- wire detector power,or door holder. imum charger current-5.0 A. • Steady, March Time (120 PPM), Two Stage, Temporal, or • Secondary power auxiliary outputs-T62 on CPS-24 Board: UZC Zone-Coded and Non-Coded devices - software- -24V @ 0.5A, power limited. selectable by circuit. -5V @ 0.15A, power limited. • Universal Zone Coder (UZC-256) option supports for pro- � Wiring: utilizes wire sizes 12 to 18 AWG(3.1 to 0.78 mm2). grammable coded outputs. Up to 256 different codes. • Auxiliary Outputs:24V @ 0.5A and 5V @ 0.15A. • SLC specifications: Average SLC current is 1.287 mA. SLC data is transmitted between 24.0 VDC, 5 VDC, and 0 VDC • Charges 12 to 200 AH batteries with full supervision. The at approximately 3.33 Kbaud. charger on the ACPS may be disabled via software. When gattery fuse(F2): 15A, Fast-acting. disabled,a separate,external charger is required,for exam- � ple a CHG-120. • Weight:4.5 Ib. • May be used to provide battery backup for multiple ACPS suppi�es. ACPS Programming • AC loss detection, brownout detection, and AC loss delay The ACPS-610(E) is programmable via the simple-to-use reporting. PK-PPS programming utility, which requires a Windows� PC • Power-limited outputs. with a USB port and cable. Programming may be performed • Isolated Signaling Line Circuit(SLC)interface. during an on-line session with the ACPS-610(E), or previously saved programs may be downloaded to individual ACPS- • Selectable ground fault detection. 610(E) units.The ACPS-610(E)requires the use of a minimum • Canadian two stage operation. of 5 SLC address points, and will use up to 14 SLC address points to fulfill requirements for Canadian supervision and two stage operation. NOTE: PK-PPS is available for download from www.magni- fire.com. DN-60244:C3•4/23/2012—Page 1 of 2 � Product Line Information ACPS-610:Addressable charger power supply,with selectable Labet G1 s�cnaa�ess�n�: built-in synchronization, and four built-in control modules. Sev- Charger. SA chaige�55�200AH� Monilor Generat b syn�rype: E����na�[uzc� o���,�n: n.i eral mounting options available(see below). w/SysEem Sensor�lntemal Output 2 6+2 s��e��e���e ves ou�v��z 6�3 ACPS-610E: Same as ACPS-610, but confi ured for 220/240 Reporling: IJSACFad tlulput-0: b*4 g Delay: 2hours SignalSilence: b+s VAC operation. o�tP�ci_ Nacs���h«��zEa CAB-PSi: The CAB-PS1 can house one ACPS-610(E) and Ou{pu{z�, NAC Synchronized o��Pu�a: �aaccons�an� two 12 AH batteries. Dimensions: 15.218" (38.654 cm) high x Oulput 4: Pow�e�ReseEtahlE 14.5"(36.83 cm)wide x 3.562" (9.048 cm)deep with door. SEISKIT PS/2/4: Seismic kit for mounting ACPS-610 in a CAB-PS1. Includes bracket for two 12 AH batteries. DR-PSi: When installing an ACPS-610(E) into an older ver- <Back ��n�sn can��� � sion of the CAB-PS1 used for an ACPS-2406(E), the new � wider door must be ordered for use with the older version Example of Programming cabinet. for the ACPS-610 Using 6 Addresses BB-25: The BB-25 can house one ACPS-610(E) and two 12 volt, 26 AH batteries. BB-100:The BB-100 can house one ACPS-610(E)and two 12 � volt,55 AH or 100 AH AH batteries. �abei: a� s�c�ae�e.$o,9 BB-200: The BB-200 can house one ACPS-610(E) and four chd�9�� �.�na����ee zar,,yi Mq„aa�rc�,r,dr n 12 volt, 100 AH batteries. Code Type: Canadian Oulpull: b*1 DualS�age�. ? Ouiput2: b+2 sYn�rYpe Exce�naA�uzcd owPU�3 b.� CAB-4 Series: The ACPS-610(E) can mount in any of the wrsy���msg�,s4���,c��na� o��P��a b*a CAB-4 Series cabinets with CHS-PS or CHS-BH. See DN- Silencea6le: Yes Signal5ilence: b+5 Reporting: Canadian 5mu61eMoniloiing�. 6857. AC Fail: b+6 oU�p���,: r�acc��ea B���e1Y b°' EQ Cabinet Series: The ACPS-610(E) can mount in any of Output 2_ P�war Reseua64e Eaflh FaulE� b.E Output3 DooiHo�der305ecRe�ease Charqee b.9 the EQ Cabinet Series cabinets using CHS-6.See DN-60229. Outpul4� NACSynchnonized 6ual5tage� o��;��z n`.;,° MARINE-EQ System: Protects equipment in shipboard and ou�Pu�3: b�,z waterfront a lications. For a full list of re uired and o Uonal o��e���� n.ia PP� q P� equipment,see DN-60688. <ea�k ��n�sn ca�,�e� a CHS-PS/CHS-6: Chassis used to mount the ACPS-610(E) in � row 1,2,or 3 of the CAB-4 or EQ series enclosure. Example for ACPS-610 CHS-BH: Battery mounting chassis that holds up to two 12AH Using Canadian Reporting with Two Stage batteries on a CHS-PS. Batteries: ACPS-610(E) battery charging circuit range is 12 - 200 AH.See DN-6933. Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635. • ULC Listed: S635. • FM Approved. • CSFM: 7315-0028:0248, 7165-0028:0224, 7165- 0028:0243. • MEA#30-08-E. • FDNY: COA#6085,#6098. When used with the MARINE-EQ, appropriate seismic bracket, and marine approved devices, the ACPS-610(E) is approved by the following agencies: • US Coast Guard: 161.002/50/0(Standard 46 CFR). Notifier0, FlashScanO, System Sensor0, and SpectrAlertO are registered • Lloyd's Register: 11/600013(ENV 3 category). trademarks of Honeywell International Inc. WindowsOO is a registered trademark of Microsoft. • AmeriCan BurOau Of Shipping(ABS). �02012 by Ho�eywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60244:C3•4/23/2012 DN-6933:C1 •E-205 BAT Series Batteries �1 N OT 1 F 1 E R° Sealed Lead-Acid � by H o n eywe I I General BAT Series Batteries are Power Sonic brand batteries. BAT Series (or Power Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. - Features • Provide secondary power for control panels. • Sealed and maintenance-free. • Overcharge protected. - • Easy handling with leakproof construction. ssss�o�.;P9 • Ruggedly constructed, high-impact case (ABS, polystyrene, or polypropylene,depending on models). �rdering Information • Long service life. • Compact design. BAT-1250-BP: 10-unit bulk pack of BAT-1250(12 V 5 AH) BAT-1270-BP:5-unit bulk pack of BAT-1270(12 V 7 AH) Agency Listings and Approvals BAT-12120-BP:4-unit bulk pack of BAT-12120(12V 12 AH) The listings and approvals below apply to BAT Series Batteries. BAT-12180-BP:2-unit bulk pack of BAT-12180(12 V 18 AH) In some cases, certain modules may not be listed by certain BAT-12260-BP:2-unit bulk pack of BAT-12260(12 V 26 AH) approval agencies, or listing may be in process. Consult factory gAT-12550:single battery(12 V 55 AH) for latest listing status. UL Recognized Components: MH2O845(Power-Sonic) BAT 121000:single battery(12 V 100 AH) Part Number Reference � Specifications Battery DIMENSIONS Description Pa� Power Number Sonic Part Nominal Width Depth Height Height over yyeight Number Nominal Capacity terminal Voltage V @ 20 hr. rate A.H. in. mm in. mm in. mm in. mm Ib. kg. BAT-1250 PS-1250 12 5 sealed 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 BAT-1270 PS-1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 2.99 76 6.57 167 6.57 167 12.6 5.8 BAT-12260 PS-12260 12 26 sealed 6.56 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12250 12 55 sealed 9.04 230 654 138 8.2 208 8.98 228 36 16.33 BAT-121000 PS-121000 12 100 sealed 12 305 6.6 168 8.2 208 8.98 228 68 30.84 DN-6933:C1•7/13/2011-Page 1 of 2 Characteristic Discharge Curves Effect of Temperature on Capacity �2o°io 6.5 13 1000�0 --- -0.5 C � 6.0 12 ----- -0.1 C a� m �° 5.5 11 � 80% -0.25 C j tOC � --- -0.6 C � 5.0 10 ' 0.175C o.5C y 60% � ---° -1 C . o25C •� I i-°-- -2 C C0 4.5 9 0.6C a I I ; �j 40% ' � - 4.0 8 � � 3C 2C 1C 2�% - 3 O o � . � 1 2 3 5 10 20 30 60 2 3 5 10 20 30 Q% '� I�minutes hours� -20° -10° 0° 10° 20° 30° 40° 50° 60° Discharge Time @ 20°C(68°F) Temperature(Degrees C.) 100% Charging is NOT 90% necessary unless 100%of capacity � is required. � ao°io at left: 0 5�C Charging before pS-121000 �, ��o�o (41°F) use is necessary c --- . _ , — _ _. � to he�p recover Shelf-Life � full capacity. � so°io and Storage a �� Charge may Q 50% fail to restore m 40°C 30°C 20°C fu�l capacity. v (104°F) (86°F) (68°F) DO NOT 3 40% let batteries reach this state. 0% � 0 2 4 6 8 10 12 14 16 18 20 Standing Period(Months) 14.0 V I I Ambient Temperature 20°C(68°F) 13.0 V ' ' � ,2.ov --- – ! -- -- --- — atleft: `° __ PS-121000 > ,�.o v � Discharge � ,o.ov 20A �oA 5.OA Characteristics � 50A 9.0 V Final 100A � Voltage � 8.0 V 200A i 1.2 2.4 6 12 24 36 481 2 4 6 8 10 20 40� MINUTES � HOURS Discharge Time NOTIFIERO is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. �02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6933:C1•7/13/2011 DN-6940:B1 •D-115 . � L D 160 NOTI FI E R° Liquid Crystal Display � by Honeywell General � �� The LCD-160 is a 640-character Liquid Crystal Display (LCD) - - - _ _� . annunciator and remote control for the NOTIFIER NFS-3030/ I�' � NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030's 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and ° can display other panel information. r � LCD-160 Features ; � . • 640-character Liquid Crystal Display with backlit control. �-,. --W--,W---�°-� �-� „,, �.,� .�" • On-board input, output, and status indicators to support �� � � �° � diagnostics. � „�, a�i. �. �. • Software upgrades and foreign-languages character sets "�� via serial port from a panel or other device using the Remote Data Port(RDP)interface. Upgrades do not require the replacement of any programmable devices. • Rubberized keypad. • Input for AKS-1 B key switch. • Fits in two ACS annunciator module locations. • Display and Control Center(DCC)participation/indication. Current draw: Standby current: 0.300 A with backlight on, 0.075 A with backlight off. Alarm current: 0.325 A with back- RDP Interface iignt on,all LEDs active. Any communication between the control panel and any RDP RDP BUS WIRING SPECIFICATIONS device,such as the LCD-160,occurs over an RDP interface. Wiring distance:4000 feet(1219.2 m)at 18 AWG(0.78 mm2) • RDP interface communication is supervised by the FACP between the panel and the last device on the RDP bus (sub- and the LCD-160. ject to system's power restrictions). • RDP bus can drive up to 32 RDP devices. The FACP must Wiring size: 18 to 12 AWG (0.78 to 3.1 mmz) twisted-pair be at one end of the bus;the last RDP device on the circuit cable,with characteristic impedance of 120 ohms±20%. must have an enabled end-of-line resistor. Wire resistance: Limit total wire resistance to 100 ohms on • Each LCD-160 on the bus requires a non-resettable 24 the RDP bus, and 10 ohms on the RDP device power circuit. VDC power connection. The power circuit is inherently Unloaded resistance between RDP connectors must be supervised and a loss of power registers as a communica- greater than 1 K ohm.A remote power supply is required if total tion failure at the control panel. power wiring resistance exceeds 10 ohms. • The LCD-160 can be powered by a regulated remote power NOTE: 1)DO NOT RUN CABLE adjacent to, or in the same con- supply listed for fire-protective signaling use. If the 24 VDC duit as: 120 VAC service;"noisy"electrical circuits that are power- power comes from a non-power-limited source, it must ing mechanical bells or horns;audio circuits above 25 Vrms;motor remain separate from the power-limited RDP bus. control circuits; SCR power circuits; or non-power-limited circuits. 2) Refer to LCD-160 Manual,document no.51850,if RDP devices Specifications are to be mounted in SEPARATE CABINETS or powered by REMOTE POWER SUPPLIES. Input supply voltage (TB2): Regulated, filtered 24 VDC via pHYSICAL SPECIFICATIONS non-resettable power supply interface listed for fire-protective signaling use. Sources can be: panels with integrated power Temperature/humidity range: This system meets NFPA supplies, main power supplies (AMPS-24, etc.), auxiliary requirements for operation at 0 -49°C/32 - 120°F and at a power supplies (APS2-6R, etc.); or a compatible accessories relative humidity 93% ± 2% RH (noncondensing) at 32°C ± output. If RDP devices are to be powered by separate power 2°C (90°F ± 3°F). However, the useful life of the system's supplies, a common reference connection must be estab- standby batteries and the electronic components may be lished. adversely affected by extreme temperature ranges and humid- Data communications port (TBi): Power-limited RDP inter- ity. Therefore, it is recommended that this system and its face. peripherals be installed in an environment with a normal room temperature of 15-27°C/60-80°F. Shipping weight:2.50 Ib. (1.134 kg) DN-6940:61•8/31/2011—Page 1 of 4 LCD-160 Interface and Indicators The liquid crystal display is 40 characters wide and 16 lines Trouble: Scroll/display a list of associated events. deep, and displays all programming screens and other infor- pther Event: Scroll between prealarm and disabled events. mation. The keypad is functional only when an entry is requested by the system. Enter or change fields and issue For complete information on key functions and effects on dif- commands on the display by using the two types of keys on ferent panels, refer to the LCD-160 Manual and panel manu- the keypad:fixed function and soft keys. als. Fixed function keys are the ten keys labeled on the front of Soft keys are the six keys to the right and left of the display. the LCD-160, operating at all times on all screens unless oth- Use them to select commands that appear on the display for erwise noted. With both an active command center and DCC each different screen. Refer to the screens in the LCD-160 enabled at the panel, Acknowledge, Signal Silence, System Manual for descriptions of the applicable soft keys. Reset, and Drill require permission before they can be pro- STATUS LED INDICATORS cessed. Acknowledge: Press to respond to any event or trouble sig- Power (green) illuminates when AC power is within normal nal. If enabled,silences the LCD-160 piezo sounder.Sends an operating limits. acknowledge message to the panel. Fire Alarm(red)illuminates when at least one fire alarm event Signal Silence: Press to send a system silence command to exists. It will flash if any of these events are unacknowledged. the panel, with the particular silencing action information Pre-Alarm(red)illuminates when at least one pre-alarm event stored at the FACP. Verification screen appears on networked exists. It will flash if any of these events are unacknowledged. displays. Security (blue) illuminates when at least one security event System Reset: Press to send a system reset command to the exists. It will flash if any of these events are unacknowledged. panel,with the particular reset action information stored at the Supervisory (yellow) illuminates when at least one supervi- FACP.Verification screen appears on networked displays. sory event exists. It will flash if any of these events are unac- Drill: Press (hold for two seconds) to activate all silenceable knowledged. fire output circuits. System Trouble (yellow) illuminates when at least one trou- Lamp Test: Press to test the LED indicators and the piezo, or ble event exists. It will flash if any of these events are unac- display firmware version numbers. knowledged. Fire Alarm: Scroll/display a list of associated events. Other Event(yellow)(future release). Security: Scroll/display a list of associated events. Supervisory: Scroll/display a list of associated events. �J4 �',� � J3 �z J1 � I.l LCD 1Iz BACKLIGHT LCD�� �O KEYSWITCH ��?z LCD 19° °20 �(±) P(+,`��� � �POWER 0000000000000000 �+ IN �000000ee000�0000� �J +24VDCOUT STATUS o ° TB2 o (`�immiimmmiiiimiiiiiii'� o COMMON IN LED11 _ ° - _ , CoMMON oUT - � = ° ^ RDP ° _ _ - TB1 RDP+ MICRO FAIL ° � �,miumiinmiiniminiinii,� ° " RDP+ LED14 �00000a0000000000{— RDP- 00000e0000000000� RECEIVE RDP- SW17� LED 12 REF E TRANSMIT REF � LED 13 EARTH Page 2 of 4—DN-6940:B1 •8/31/2011 Signals Silenced (yellow) illuminates if notification appli- work control to alternate network control centers.This protocol ances have been silenced. It flashes if some, but not all, of the allows for a "request for control" from another networked NACs have been silenced. panel, which will be accepted or rejected from the current Point Disabled (yellow) illuminates when at least one device DCC. A 15-second time-out allowance provides for an auto- has been disabled. It will flash until all disabled points have matic passing of control in the event there is no response from been acknowledged. the original DCC. If the NFS-3030/NFS2-3030 panel associ- ated with an LCD-160 has been programmed to participate in Controls Active (green) illuminates when the LCD-160 DCC, all remote displays with Local Control ON will automati- assumes control of the node as a primary display. cally participate. DIAGNOSTIC LED INDICATORS Status, LED11 (green), bi�nks wr,en ►r,e �co-1so �s on. v�s�- Agency Listings and Approvals ble to the installer/troubleshooter only. These listings and approvals apply to the LCD-160. In some Receive, LED12 (green), blinks when data is received from cases, certain modules or applications may not be listed by the panel.Visible to the installer/troubleshooter only. certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. Transmit, LED13 (green), blinks when data is transmitted to UL: S635 the panel.Visible to the installer/troubleshooter only. � • ULC: S635 Microfail, LED14 (yellow), illuminates if the microcontroller fails. Visible to the installer/troubleshooter only. • MEA:8-04-E (annunciator only) • FDNY:COA#6065(with NFS2-3030) Event Handling and the • CSFM: 7120-0028:0227,7165-0028:0224 Display and Control Center • FM Approved UL and ULC require that when multiple command and control centers are instailed, only one operator at any location can be in control at any given time for functions such as acknowledge, silence, and reset. This is called the Display and Control Cen- ter(DCC). DCC operation provides a mechanism to pass net- RDP Bus Wire Runs FACP LCD-160 Power 12 to 18 AW G _ (3.1 to 0.78 mm2) LCD-160 non-resettable _ �: Two-wire RDP Bus 4000 feet(1219.2 m)max. • ' ' • ' power-limited and supervised Sample Screen: Point Event Display ACKNOWLEDGED TROUBLE ELEVATOR LOBBY EAST WING FIFTH FLOOR Z239 SMOKE (PHOTO) 11:58:45A WED JUN 26, 2�03 L03D002 EVENT COUNTS FIRE ALARh1S:000 PREALARM:000 TROUBLE:001 SUPERVISORY:000 SECURITY:00� DISABLE:000 11�58�46A WED JUN 26, 2011 � �' SIGNAL SILENCE ' � �' MORE INFORMATION SYSTEM RESET ' � a' PROGRAM MENU ' � DN-6940:61•8/31/2011—Page 3 of 4 Product Line Information LCD-160:640-character Liquid Crystal Display annunciator. TR-ABS2D: Optional trim ring for semi-flush mounting ABS- 2D(R). Backboxes VP-2B: Vented Dress Panel for use with the ADP-4B dress The following backboxes can be surface- or semi-flush- panel installed in the top tier of a NOTIFIER cabinet. It covers mounted to provide an enclosure for remote mounting. Use the gap between the dress panel and top of the cabinet. with 1/2" (1.27 cm)conduit in the provided knockouts. AKS-16: Annunciator Key Switch provides access security for ABS-2D (black) and ABS-2DR (red): Surface- or semi-flush the control switches on the LCD-160. Key-switch kit includes enclosure for remote mounting. Mounts an LCD-160 directly to key, hardware, and an annunciator label. the enclosure's hinged dress plate. The ABS-2D and ABS- 2DR do NOT support the installation of the AKS-1 B key- switch. Not for use in Canadian applications.Optional trim ring TR-ABS2D for semi-flush mounting. Dimensions, box: 12.0" (30.480 cm) H x 12.0" (30.480 cm) W x 3.797" (9.644 cm) D (NOTE: The black ABS-2D is slightly deeper). Dimensions, door: 12.0" (30.480 cm) H x 12.0" (30.480 cm) W x 1.250" (3.175 cm) D. ABS-4D(black)and ABS-4DR (red): Surface- or semi-flush- enclosure for remote mounting. Mounts an LCD-160 and two annunciators directly to the enclosure's hinged dress plate. The ABS-4D and ABS-4DR do NOT support the installation of the AKS-1 B key-switch. Dimensions, box: 11.97" (30.40 cm) H x 19.87" (50.47 cm) W x 3.5" (8.89 cm) D. Dimensions, door: 11.97" (30.40 cm) H x 19.87" (50.47 cm) W x 1.250" (3.175 cm) D. ABF-2B: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Not for use in Canadian applications. Includes a painted black metal trim plate [11" (27.94 cm) high x 10.625" (26.99 cm) wide] and adhesive-backed annunciator label. 9.938" (25.24 cm) high x 9.188" (23.34 cm)wide x 3.75" (9.525 cm)deep. ABF-2DB: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Does not support the installation of AKS-1 B. Box dimensions: 9.938" (25.24 cm) high x 9.188" (23.24 cm) wide x 3.75" (9.525 cm) deep.Door dimensions: 11" (29.94 cm) high x 10.375" (26.35 cm)wide x 0.75" (1.9 cm)deep. ABF-46: Black flush enclosure for remote mounting of one LCD-160 and two annunciator modules directly to the enclo- sure's dress plate. Knockouts are provided for use with 1/2" (1.27 cm) conduit. Includes a painted black metal trim plate [11"(27.94 cm)high x 19.375"(49.21 cm)wide]and an annun- ciator label. 9.938" (25.24 cm)high x 17.75" (45.09 cm)wide x 2.5" (6.35 cm)deep. CAB-4 Series cabinets: Surface- or semi-flush-mounted, in sizes to accommodate one to four rows of equipment plus bat- teries (up to two 26 AH batteries). Four sizes are available. Doors are ordered separately, and feature reversible hinges to mount doors on the left or right side. Doors also open a full 180°. Keylocks are included. For dimensions and further infor- mation,see datasheet DN-6857. ACCESSORIES DP-DISP: Dress Panel Display for cabinet mounting of an LCD-160. LCD-160 mounts directly to the dress panel, which hinge-mounts to the top tier of a CAB-4 Series backbox. NOTIFIERO is a registered trademark of Honeywell International Inc. ADP-4B: Annunciator Dress Panel-4B (black) for cabinet �02011 by Honeywell International Inc.All rights reserved.Unauthorized use mounting of an LCD-160. LCD-160 mounts directly to the of this document is strictly prohibited. dress panel, which hinge-mounts to the tier of a CAB-4 Series backbox. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4-DN-6940:B1 •8/31/2011 DN-6937:D FAPT-851 (A) � N OT 1 F 1 E R° Acclimate0 PIusT'" Multi-Sensor J Low-Profile Intelligent Detector by H o n eywe I I - - - - � - - General The Notifier FAPT-851(A) AcclimateOO PIusT"' detector is an - intelligent, addressable, multi-sensing, low-profile detector , designed for use with Notifier Notifier Onyx and CLIP series � ,:� °-. ' Fire Alarm Control Panels(FACPs). '` ' The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- �� mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus * detector adjusts its sensitivity automatically, without operator o intervention or control panel programming. i���� m Areas where the Acclimate Plus detector is especially useful ��,� 3 include office complexes, schools, college campuses, manu- � facturing and industrial facilities, and anywhere else the use of FAPT-851(A) in B210LP(A) Base ` a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScanOO (U.S. Patent 5,539,389) is a communication pro- tocol developed to greatly enhance the speed of communica- tion between analog intelligent devices and compatible Specifications systems. Intelligent devices communicate in a grouped fash- Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. ion. If one of the devices within the group has new information, ,�,�ith classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with the panel's CPU stops the group poll and concentrates on sin- systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic gle points. The net effect is response speed greater than five CLIP systems;0.5, 1,2,3,and 4%/ft.with FlashScan systems. times that of earlier designs. Size:2.0"(5.3 cm) high;base determines diameter. F@atl1P@S -B210LP(A): 6.1" (15.5 cm)diameter. • Automatically adjusts sensitivity levels without operator -B501(A):4.1" (10.4 cm)diameter. intervention or programming. Sensitivity increases with -B200S(A):6.875" (17.46 cm)diameter. heat. -B200SR(A):6.875" (17.46 cm)diameter. • Microprocessor-based, combination photo and thermal _B224RB(A):6.2" (15.748 cm)diameter. technology. Shipping weight:5.2 oz. (147 g). • Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels(FACPs). Operating temperature:0°C to 38°C(32°F to 100°F). • Addressable-analog communication. UL-Listed velocity range: 0-4000 ft./min. (1219.2 m/min.), • Sleek, low-profile design. suitable for installation in ducts. • Two-wire SLC connection. Relative humidity: 10%-93%noncondensing. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 Thermal sensing rating: fixed-temperature setpoint 135°F on FlashScan systems). (57°C)• • Addresses can be viewed and changed without electronic ELECTRICAL SPECIFICATIONS programmers. • Dual bi-color LED design provides 360°viewing angle. Voltage range: 15-32 volts DC peak. • LEDs lock red when in alarm. In FlashScan, LEDs flash Standby current(max.avg.):300 uA. green in standby for normal condition. Loop resistance: 50 ohms maximum; varies according to • Built-in tamper-resistant feature. control panel used. Refer to panel installation manuals. • Constructed of off-white fire-resistant plastic, designed to LED current(max.):6.5 mA @ 24 VDC("ON"). commercial standards,and offers an attractive appearance. • SEMS screws for wiring of the separate base. Installation • Several base options, including relay, isolator,and sounder. The FAPT-851(A) plug-in detector uses a separate base to • Built-in functional test switch activated by external magnet. simplify installation, service, and maintenance. A special tool • Listed to UL 268. allows maintenance personnel to plug-in and remove detec- Capable of heat-only alarm mode, enabled by a special tors without using a ladder. Suitable mounting base boxes � include: command from the panel. Smoke alarms are ignored. • Low-temperature signal at 45°F +/- 10°F (7.22°C +/- 5.54°C). DN-6937:D•12/07/2011—Page 1 of 2 • 4.0" (10.16 cm)square box. ACCESSORIES • 3.5" (8.89 cm)or 4.0" (10.16 cm)octagonal box. F110: Retrofit flange to convert B210LP to match the 6710LP • Single-gang box(except relay or isolator base). profile,or to convert older high-profile bases to low-profile. NOTE: The FAPT-851(A) detector has the unique ability to adjust F110BP: Bulk pack of F110;package contains 15. sensitivity according to the environment, based on heat and F210: Replacement flange for B210LP(A)base. smoke levels.Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes.An example of RA100Z(A): Remote LED annunciator. 3—32 VDC. Fits U.S. an incorrect application would be near or in line with the output of a single-gang electrical box. Supported by B210LP(A) and self-contained heater. B501(A)bases only. Agency Listings and Approvals SM6600: Surface mounting kit for use with B210LP(A). M02-04-00:Test magnet. These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not M02-09-00:Test magnet with telescoping handle. be listed by certain approval agencies,or listing may be in pro- XR2B: Detector removal tool. Allows installation and/or cess. Consult factory for latest listing status. removal of FlashScanOO Series detector heads from base in • UL Listed: S1115. high ceiling installations. • ULC Listed: S1115. T55-127-010: Detector removal tool without pole. • MEA Listed:225-02-E. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 • FM Approved. m)sections. • CSFM: 7272-0028:0206. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). • Lloyd's Register: 1 1/60001 3 (NFS2-640, NFS-320/NFS- 320C,excluding B210LP(A)). • Maryland State Fire Marshal: Permit#2122. Ordering Information NOTE:"A"suffix indicates ULC Listed model. FAPT 851: Low-profile intelligent multi-sensor detector. FAPT 851 A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES NOTE:"A"suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base; standard U.S. flanged low- profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B5016P: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tem- poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0 mm2). Relay type Form-C. Rating: 2.0 A@ 30 VDC resistive; 0.3 A@ 110 VDC inductive; 1.0 A@ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- Iat01'baSeS. NotifierOO,ONYXO,FlashScanO,and Acclimate0 are registered trademarks and Acclimate PIusT"^is a trademark of Honeywell International Inc. �02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6937:D•12/07/2011 DN-60689:B FCO-851 (A) IntelliQuadTM PLUS � o Advanced Multi-Criteria J N �T 1 F 1 E R Fire/CO �etector by H o n eywe I I - - - - , - - General World-class fire and carbon monoxide (CO) detection com- � �- bined in a single addressable device provides a practical solu- � tion for today's market. "-�"�►- The IntelliQuad PLUS FCO-851(A) Advanced Multi-Criteria ,, Fire/CO Detector is a plug-in, addressable device that pro- ` vides both fire and carbon monoxide (CO) detection. For fire, : � � the detector combines four separate sensing elements in one �,'� ` unit(smoke, CO, light/flame, and heat)to sense multiple com- 4� ponents of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. ;� � � For CO, the detector's electrochemical sensing cell creates a � � separate signal for life safety CO detection. � CO is a colorless, odorless, and deadly gas that is virtually �` impossible to detect with the human senses. It is released whenever carbon-based fuels (from fossil fuels to firewood) ��` a burn without enough oxygen to form CO2. Because the poten- �" tial exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in `° commercial spaces continues to increase across the U.S. and FCO-851(A) in B200S(COA) Sounder Base Canada. The FCO-851(A) is listed to the UL 268 standard for smoke detectors and the UL 2075 standard for system-con- nected life safety carbon monoxide monitoring. The FCO-851(A) should be used in conjunction with the Sensitivity Settings and B200S(COA) intelligent sounder base, which can generate Suggested Applications either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. • Level 1: 1%/ft of smoke. Suggested for very clean envi- ronments such as laboratories. The B200S(COA)recognizes the System Sensor synchroniza- Level 2: 2% / ft of smoke. Suggested for clean environ- tion protocol.This enables it to be used as a component of the � ments such as offices. general evacuation signal—along with other System Sensor horns, horn strobes, and chimes — when connected to a • Level 3: 3%/ft of smoke. Suggested for moderately clean power supply or Fire Alarm Control Panel (FACP)output capa- environments such as hotel rooms,dorm rooms. ble of generating the System Sensor synchronization pulses. • Level 4: 3%/ft of smoke with different algorithm process- With each sounder base carrying a unique address,the FACP ing and weighting of sensor elements. Suggested for hotel can then command an indvidual sounder — or a group of rooms near a shower, boiler rooms. sounders—to activate.The command set from the panel can . Level 5:4%/ft of smoke. Suggested for equipment rooms, be tailored to the specific event, allowing selection of volume, kitchens,paint shops. tone,and group. • Level 6:Thermal alarm at 135°F(57°C). NOTE:The FCO-851(A)is compatible with the NFS-320(C), NFS- Once the CO cell has reached end-of-life, the CO sensor no 320SYS, NFS2-640, and NFS2-3030 operating with firmware ver- longer provides life safety protection; however, when the fire sion 17.0 (or higher) in FlashScanO mode; CLIP mode not sup- detector enters Photo,Thermal, Infrared (PTIR) mode,the fol- ported. lowing sensitivities apply: Features • Level 1: 1% /ft of smoke. Suggested for very clean envi- ronments such as laboratories. • Unique ability to detect all four major elements of a fire. . Level 2: 2% / ft of smoke. Suggested for clean environ- • Separate CO detection signal. ments such as offices. • Highest nuisance alarm immunity. • Level 3: 3%/ft of smoke. Suggested for moderately clean • Automatic drift compensation of smoke sensor and CO cell. environments such as hotel rooms,dorm rooms. • Uses only one address on the SLC. • Level 6:Thermal alarm at 135°F(57°C). • RealTestOO CO testing capability. • Separates audible signal for fire or CO alarm when used Specifications with the B200S base(6200SCOA in Canada). pHYSICAL SPECIFICATIONS • CO cell end-of-life warning and fault. FlashScan operation. Size: 3.46" (8.79 cm) high x 6.875" (17.46 cm) diameter � installed in B200S(COA) base. Shipping weight:4.6 oz. (130.41 g). Color: Ivory. DN-60689:B•12/3/2012—Page 1 of 2 Operating humidity range: 15% — 90% relative humidity (noncondensing). Operating temperature:0°C to 38°C(32°F to 100°F). Air velocity:0—4000 ft./min. (0 to 20 m/sec.). ELECTRICAL SPECIFICATIONS Operating Voltage range: 15—32 volts VDC. Standby current (max. avg.): 300 �A at 24 VDC (one com- munication every 5 seconds with LED blink enabled). Maximum Alarm Current(LED on):7.2 mA at 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Concentration Maximum Alarm Time of CO Response 70(+/-5)PPM 240 min(not less than 60 min) 150(+/-5)PPM 50 min(not less than 10 min) 400(+/-10)PPM 15 min(not less than 4 min) Ordering Information NOTE:"A suffix indicates ULC listed model. FCO-851: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector, ULC listed. B200S: Intelligent programmable sounder base. B200SCOA: Intelligent programmable sounder base, ULC listed. Includes CO detector markings in English and French. M02-04-00: Detector Test Magnet. M02-09-00:Telescoping Test Magnet. Agency Listings and Approvals The listings and approvals below apply to the primary product. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S1115(FCO-851). • ULC: S1115(FCO-851A). • CSFM: 7275-0028:0264. Intelli�uadT"'is a trademark and NOTIFIERO,RealTestO and FlashScanO are registered trademarks of Honeywell International Inc. �02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60689:B•12/3/2012 DN-6936:B•H-211 FST-851 (A) Series � N OTI F 1 E R° Intelligent Thermal (Heat) Detectors � with FlashScano by H o n eywe I I - - - - , - - General Notifier FST-851(A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- " _ tional detectors. Point ID capability allows each detector's " address to be set with rotary, decimal address switches, pro- �� ,,,. viding exact detector locations. FST-851(A) Series thermal f�' , detectors use an innovative thermistor sensing circuit to pra �" � duce 135°F/57°C fixed-temperature (FST-851/A) and rate-of- � � rise thermal detection (FST-851 R/A) in a low-profile package. l FST-851 H(A) provides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelli- .��w gent property protection in a variety of applications. FST- 851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels(FACPs). FlashScanOO (U.S. Patent 5,539,389) is a communication pro- FST-851(A) in B210LP(A) Base m tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices • 94-5V plastic flammability rating. communicate in a grouped fashion. If one of the devices within • Remote LED output connection to optional RA100Z(A) the group has new information, the panel's CPU stops the remote LED annunciator. group poll and concentrates on single points.The net effect is . Optional sounder, relay,and isolator bases. response speed greater than five times that of earlier designs. • Optional flanced surface mounting kit. Features Specifications • Sleek, low-profile,stylish design. • State-of-the-art thermistor technology for fast response. Size:2.1"(5.3 cm) high; base determines diameter. • Rate-of-rise model (FST-851 R/A), 15°F(8.3°C) per minute. —B210LP(A): 6.1" (15.5 cm)diameter. • Factory preset fixed temperature at 135°F(57°C); high-tem- —B501(A):4.1" (10.4 cm)diameter. perature model fixed at 190°F(88°C). —B200S(A):6.875" (17.46 cm)diameter. • Addressable by device. —B200SR(A):6.875" (17.46 cm)diameter. • Compatible with FlashScanOO and CLIP protocol systems. —B224RB(A):6.2" (15.748 cm)diameter. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 —B224BI(A): 6.2"(15.748 cm)diameter. on FlashScan systems). Shipping weight:4.8 oz. (137 g). • Two-wire SLC connection. Operating temperature range: FST-851(A) Series, FST- • Visible LEDs"blink"every time the unit is addressed. 851 R(A):—20°C to 38°C(-4°F to 100°F); FST-851 H(A):—20°C • 360°-field viewing angle of the visual alarm indicators (two to 66°C(-4°F to 150°F). bi-color LEDs). LEDs blink green in Normal condition and Detector spacing: UL approved for 50 ft. (15.24 m) center to turn on steady red in Alarm. center. FM approved for 25 x 25 ft. (7.62 x 7.62 m)spacing. • Integral communications and built-in device-type identifica- Relative humidity: 10%—93%noncondensing. tion. Remote test feature from the panel. Thermal ratings: fixed-temperature setpoint 135°F (57°C), � rate-of-rise detection 15°F (8.3°C) per minute, high tempera- • Built-in functional test switch activated by external magnet. ture heat 190°F(88°C). • Walk test with address display (an address of 121 will blink ELECTRICAL SPECIFICATIONS the detector LED 12-(pause)-1). • Low standby current. Voltage range: 15-32 volts DC peak. • Backward-compatible. Standby current (max. avg.): 300 uA @ 24 VDC (one com- • Built-in tamper-resistant feature. munication every 5 seconds with LED enabled). • Designed for direct-surface or electrical-box mounting. LED current(max.):6.5 mA @ 24 VDC("ON"). • Sealed against back pressure. • Plugs into separate base for ease of installation and main- App��C1t1011S tenance. Separate base allows interchange of photoelec- Use thermal detectors for protection of property. For further tric, ionization and thermal sensors. information, go to systemsensor.com for manual 156-407-00, • SEMS screws for wiring of the separate base. Applications Manual for System Smoke Detectors, which pro- • Constructed of off-white fire-resistant plastic, designed to vides detailed information on detector spacing, placement, commercial standards, and offers an attractive appearance. zoning,wiring,and special applications. DN-6936:6•12/07/2011—Page 1 of 2 Installation with ANSI Temporal 3, ANSI Temporal 4, continuous tone, The FST Series plug-in intelligent thermal detectors use a sep- marching tone, and custom tone. arate base to simplify installation, service, and maintenance. B200SR(A): Intelligent sounder base capable of producing Installation instructions are shipped with each detector. A spe- sound output with ANSI Temporal 3 or continuous tone. cial tool allows maintenance personnel to plug in and remove Replaces B501 BH series bases in retrofit applications. detectors without using a ladder B224RB(A): Intelligent relay base. Screw terminals: up to 14 Mount base (all base types) on an electrical backbox which is AWG (2.0 mm2). Relay type: Form-C. Rating:2.0 A@ 30 VDC at least 1.5"(3.81 cm)deep. For a chart of compatible junction resistive;0.3 A@ 110 VDC inductive; 1.0 A@ 30 VDC induc- boxes,see DN-60054. tive. NOTE: 1) Because of the inherent supervision provided by the B224BI(A): Intelligent isolator base. Isolates SLC from loop SLC loop, end-of-line resistors are not required.Wiring"T-taps"or shorts. Maximum: 25 devices between isolator bases; see branches are permitted for Style 4 (Class "B") wiring. 2) When Note 2 under Installation. using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules ACCESSORIES and isolator bases. F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to Agency Listings and Approvals low-profile. These listings and approvals apply to the modules specified in F110BP: Bulk pack of F110;package contains 15. this document.ln some cases, certain modules or applications F210: Replacement flange for 6210LP(A)base. may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. RA100Z(A): Remote LED annunciator. 3—32 VDC. Fits U.S. single-gang electrical box. Supported by 6210LP(A) and • UL Listed: S747. B501(A)bases only. • ULC Listed: S6978. SMB600: Surface mounting kit,flanged. • MEA Listed:383-02-E. M02-04-00:Test magnet. • FM Approved. • CSFM:7270-0028:0196. M02-09-00:Test magnet with telescoping handle. • BSMI:C1313066760025. XR2B: Detector removal tool. Allows installation and/or CCCF: Certif.#2004081801000018. removal of FlashScanO Series detector heads from base in � high ceiling installations. Includes T55-127-010. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 T55-127-010: Detector removal tool without pole. (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 320C,excluding B210LP(A)). m)sections. Product Line Information NOTE:"A"suffix indicates ULC Listed model. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FS'F851A: Same as FST-851 but with ULC Listing. FST 851 R: Intelligent thermal detector with rate-of-rise fea- ture. FST 851 RA: Same as FST-851 R but with ULC Listing. FST 851 H: Intelligent high-temperature thermal detector. FST 851 HA: Same as FST-851 H but with ULC Listing. INTELLIGENT BASES NOTE:"A"suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A):Standard U.S.flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A):Standard European flangeless mounting base. B501BP: Bulk paCk Of B501; package contains 10. rvot�r�ero and FlashScanO are registered trademarks of Honeywell B200S A : Addressable Intelli ent, ro rammable sounder internationai inc. � � g p g �02011 by Honeywell International Inc.All rights reserved.Unauthorized use base capable of producing sound output in high or low volume of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6936:B•12/07/2011 DN-60054:E Intelligent Bases � N OT 1 F 1 E R° 6501(A), B200S(A), B200SR(A), J 6210LP(A), B2241 BI(A), 6224RB(A), by H o n eywe I I Mounting Kits, and Accessories - - � - - General Intelligent FlashScanOO and CLIP mounting bases and kits pro- � vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either ' a flanged or flangeless bases depending on junction box selec- '��1'��` r!' a tion (see Junction Box Selection Guide). Across this product � line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base � Flanged Mounting Base � and models employ various 12 to 24 AWG wire ranges. B501(A) B210LP(A) Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door clo- - sure and elevator recall. Isolator bases allow loops to continue -�� � to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-temporal pattern versions depending on , , a ' ' whether the signal is to be used for evacuation purposes. .��a, - � w� � Specifications Sounder Base g224RB A � B200S(A),B200SR(A) ( ) Diameter: -B501:4.1" (104 mm). Sound output: measured in a UL reverberant room at 10 feet, -B224B1, B224RB, B210LP:6.1" (155 mm). 24 Volts(continuous tone). -B200S/SR:6.875" (17.46 cm). -B200S, high-volume:Greater than 85 dBA minimum. Wire gauge: -B200S, low-volume: Greater than 75 dBA minimum. -B224BI, 6224RB: 14 to 24 AWG. -B200SR:Greater than 85 dBA minimum. -B210LP, 6501, B200S/SR: 12 to 24 AWG. FOR B224RB, B224BI: Temperature range: Operating voltage: 15 to 32 VDC(powered by SLC). -B224B1, B224RB, B200S/SR: 32°F to 120°F (0°C to 49oC� Standby ratings: <500 NA maximum @ 24 VDC. -B210LP, 6501: -4°F to 150°F(-20°C to 66°C). Set time (B224RB only): short delay 55 to 90 msec; long Humidity range: 10%to 93%RH, non-condensing. delay 6 to 9 seconds. System temperature and humidity ranges: This system Reset time(B224RB only):20 msec maximum. meets NFPA requirements for operation at 0°C to 49°C (32°F Relay characteristics(B224RB only):two-coil latching relay; to 120°F); and at a relative humidity (noncondensing) of 85% one Form-C contact; ratings (UL/CSA): 0.9 A@ 125 VAC, 0.9 at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°� A@ 110 VDC, and 3.0 A@ 30 VDC. (89.6°F± 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be Product Line Information adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all INTELLIGENT BASES peripherals be installed in an environment with a nominal room B501: Flangeless mounting base. temperature of 15°C to 27°C(60°F to 80°F). B501A: Flangeless mounting base, ULC Listed. Electrical Ratings B501 BP: Bulk pack of B501 (10). FOR B200S/SR: B210LP: Flanged mounting base. External supply voltage: 16 to 33 VDC(VFWR) B210LPA: Flanged mounting base, ULC listed Standby current: 500 NA maximum. B210LPBP: Bulk pack of B210LP(10). Alarm current: B200S: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Temporal -B200S:25 mA maximum at high-volume setting; 3,ANSI Temporal 4, continuous tone, marching tone,and cus- 15 mA maximum at low-volume setting. tom tone. -B200SR:35 mA maximum. B200SA: Same as B200S with ULC-listing. SLC operating voltage: 15 to 32 VDC. B200SR: Intelligent sounder base capable of producing sound SLC standby current:300 NA. output with ANSI Temporal 3 or continuous tone. B200SRA: Same as B200SR with ULC-listing. DN-60054:E•7/22/2011—Page 1 of 2 B224RB: Relay base. XR2: Detector Remove Tool for use with low profile detector B224RBA: Relay base, ULC Listed. heads,and FSL-751. B224BI: Isolator base. XP-4: Extension pole for XR2/B(5 to 15 ft/1.524 to 4.572 m). B224BIA: Isolator base, ULC Listed. T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with MOUNTING KITS AND ACCESSORIES photo and ion detectors). SMB600: Surface mounting kit,flanged. WCK-200B: White detector kit, package of 10 (for use with F110: Retrofit flange for converting high-profile bases to low- photo and ion detectors). profile. F110BP: Bulk pack of F110(10). Ag@11C)/ LISt111gS a11C1 Appl'OV11S F210: Accessory flange ring for B210LP(A) base (new The listings and approvals below apply to intelligent bases as design). 6-inch diameter. noted. In some cases,certain modules or applications may not F210BP: Bulk pack of F210(10). be listed by certain approval agencies,or listing may be in pro- cess.Consult factory for latest listing status. RA100Z: Remote LED annunciator. • UL Listed:S911 RA100ZA: Remote LED annunciator, ULC Listed. • ULC Listed:S911 M02-04-00: Detector test magnet. • FM Approved M02-09-00:Test magnet with telescoping handle. • MEA:22-95-E,205-94-E Vol.2;257-06-E XR2B: Detector removal tool for current heads (T55-127-010 • CSFM: 7300-1653:0126, 7135-1653:0213, 7300-0028:0173, included). 7300-1653:0109 Junction Box Selection Guide 4.0"Sq. Single with 3.0" Base Models Gang 3.5"Oct. 4.0"Oct. 4.0"Sq. mud ring 50 mm 60 mm 70 mm 75 mm 6200S,B200SR Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable Iocal codes for appropriate recommendations. FlashScanO,NOTIFIERO and System Sensor0 are registered trademarks of Honeywell International Inc. �02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60054:E•7/22/2011 DN-6724:B3 FCM-1 (A) & FRM-1 (A) �1 N OT 1 F 1 E R� Series ►� Control and Relay Modules by H o n eywe I I - - - - � - - General FCM-1(A)Control Module: The FCM-1(A)Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- � els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A)to be acti- � �,� vated, either manual�y or through panel programming, on a l ` select(zone or area of coverage) basis. '�' � G �' 1 FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay � "'E°""'a'' � „�;o Ea�,emE„;° Module provides the system with a dry-contact output for acti- . T10E„PwR,,, _��,.,., vating a variety of auxiliary devices, such as fans, dampers, control equipment,etc.Addressability allows the dry contact to '°'•' _",.,'� ^ be activated, either manually or through panel programming, a `""", iPULTOM9 on a select basis. "`°°°°'_°°`°°"`°°"'�`° FlashScanO (U.S. Patent 5,539,389) is a communication pro- e�� tocol developed by NOTIFIER Engineering that greatly , � - enhances the speed of communication between analog intelli- ""� `� � �'"� ' gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- `� , \ � . -- ;- I° mation, the panel CPU stops the group poll and concentrates 'ff�' ., on single points.The net effect is response speed greater than _ _, five times that of other designs. FCM-1(A) Features • Built-in type identification automatically identifies these ' The FCM-1(A)is configured for a single Class B(Style Y)or devices to the control panel. Class A(Style Z) Notification Appliance Circuit. • Internal circuitry and relay powered directly by two-wire ' The FRM-1(A) provides two Form-C dry contacts that SLC loop.The FCM-1(A) module requires power(for horns, switch together. strobes,etc.),or audio(for speakers). • Integral LED "blinks" green each time a communication is Operation received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module when activated. addresses on a SLC loop (99 on CLIP loops). It responds to • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- The FCM-1(A) may be used to switch 24-volt NAC power, tion Appliance Circuit (NAC). The LED blinks with each poll • audio(up to 70.7 Vrms). received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) • Wide viewing angle of LED. notification or control circuits. • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- • Direct-dial entry of address 01- 159 for FlashScan loops, connect the supervision and connect the external power sup- 01 -99 for CLIP mode loops. ply in the proper polarity across the load device. The • Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive indication Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- Applications munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. The FCM-1(A) is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The high-level audio (speakers). The FRM-1(A) may be pro- address may be set before or after mounting. The built-in grammed to operate dry contacts for applications such as door TYPE CODE (not settable)will identify the module to the con- holders or Air Handling Unit shutdown, and to reset four-wire trol panel, so as to differentiate between a module and a sen- smoke detector power. sor address. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-I-REL Specifications for FCM-1(A) datasheet(DN-60390)for new FlashScanO releasing applications. Normal operating voltage: 15 to 32 VDC. Construction Maximum current draw: 6.5 mA(LED on). • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 NA direct poll,375 NA group • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 �A Max. (LED flashing, NAC address(01-159). shorted.) DN-6724:63•2/17/2011—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1(A� External supply voltage(between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum Current Maximum Load Application (Speakers):70.7 V RMS,50W. Rating Voltage Description Drain on external supply: 1.7 mA maximum using 24 VDC 3 A 30 VDC Resistive Non-Coded supply;2.2 mA Maximum using 80 VRMS supply. 2 A 30 VDC Resistive Coded Max NAC Current Ratings: For class B wiring system, the g A 110 VDC Resistive Non-Coded current rating is 3A; For class A wiring system,the current rat- ing is 2A. .9 A 125 VDC Resistive Non-Coded Temperature range: 32°F to 120°F(0°C to 49°C). ,5 A 30 VDC Inductive Coded (L/R=5ms) Humidity range: 10%to 93%non-condensing. 1 A 30 VDC Inductive Coded Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x (L/R-2ms) 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm)deep box. .3 A 125 VAC Inductive Non-Coded (PF=0.35) Accessories: SM6500 Electrical Box; C6500 Barrier Inductive Specifications for FRM-1(A) 1.5 A 25 VAC (PF=0.35) Non-Coded Normal operating voltage: 15 to 32 VDC. Inductive Maximum current draw: 6.5 mA(LED on). ��A 70.7 VAC (PF=0.35) Non-Coded Average operating current: 230 uA direct poll;255 uA group poll. Inductive 2 A 25 VAC (PF=0.35) Non-Coded EOL resistance: not used. Temperature range: 32°F to 120°F(0°C to 49°C). NOTE:Maximum(Speakers):70.7 V RMS,50 W Humidity range: 10%to 93%non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x Product Line Information 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x NOTE:"A"suffix indicates ULC Listed model. 2.125" (53.975 mm)deep box. FCM-1(A): Intelligent Addressable Control Module. Accessories: SMB500 Electrical Box; CB500 Barrier FRM-1(A): Intelligent Addressable Relay Module. Agency Listings and Approvals A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- SMB500: Optional Surface-Mount Backbox. tory for latest listing status. CB500: Control Module Barrier—required by UL for separat- • UL: S635 ing power-limited and non-power limited wiring in the same • ULC: S3705(A version only) junction box as FCM-1(A). • FM Approved NOTE: For installation instructions,see the following documents: • CSFM: 7300-0028:0219 • FCM-1(A)Installation document 156-1169. • MEA: 14-00-E • FRM-1(A)Installation document 156-3502. • FDNY:COA#6067,#6065 • Notifier SLC Wiring Manual,document 51253. Notifier0 and FlashScanO are registered trademarks of Honeywell International Inc. �02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6724:B3•2/17/2011 DN-6720:C•H-220 FMM-1 (A), FMM-101 (A), �1 N OT 1 F 1 E R� FZM-1 (A) & FDM-1 (A) 1� Monitor Modules with FlashScan� by H o n eywe I I - - - - � - - General Four different monitor modules are available for Notifier's intel- � _ ligent control panels for a variety of applications. Monitor mod- �:� - ules supervise a circuit of dry-contact input devices, such as � �' � `, conventional heat detectors and pull stations, or monitor and � ^ „u=a �, ` power a circuit of two-wire smoke detectors(FZM-1(A)). 1, ,;;;�`j ' FMM-1(A)is a standard-sized module(typically mounts to a 4" � =E��w.rE��PmE�� ~ [10.16 cm]square box)that supervises either a Style D (Class =�_���� A) or Style B(Class B)circuit of dry-contact input devices. � A� " s s�P a�-� ����.�,z FMM-101(A)is a miniature monitor module a mere 1.3° (3.302 ""'°" '"°`"°"' cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- ie5u`p,., =a=���=�aEP�wEa�MTF� vises a Style B (Class B) circuit of dry-contact input devices. aa,U� Its compact design allows the FMM-101(A)to be mounted in a A`a'°' A ) � � � single-gang box behind the device it monitors. � , ;,,�', , l, _� —_ FZM-1(A)is a standard-sized module that monitors and super- �.- � �r�� • o��=c � ,--:�, a vises compatible two-wire,24 volt,smoke detectors on a Style � �;:� � ,r-I'��� D(Class A) or Style B(Class B)circuit. '� �������' - � ����E��= �='� �� FDM-1(A) is a standard-sized dual monitor module that moni- , � tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, FMM-1(A)(Type H) consecutive addresses in intelligent,two-wire systems. FlashScanOO (U.S. Patent 5,539,389) is a communication pro- A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor tocol developed by NOTIFIER that greatly increases the speed (provided) terminates the Style B circuit. No resistor is of communication between analog intelligent devices. Intelli- required for supervision of the Style D circuit. gent devices communicate in a grouped fashion. If one of the FMM-1(A) OPERATION devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The Each FMM-1(A) uses one of the available module addresses net effect is response speed greater than five times that of on an SLC loop. It responds to regular polls from the control other designs. panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates FMM-1(A) Monitor Module that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- • Built-in type identification automatically identifies this device tions on the loop). as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power FMM-1(A) SPECIFICATIONS required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI) immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 350 NA (LED flashing), 1 com- • Direct-dial entry of address: 01 – 159 on FlashScan loops; munication every 5 seconds,47k EOL. 01 –99 on CLIP loops. Maximum IDC wiring resistance:40 ohms. • LED flashes green during normal operation (this is a pro- EOL resistance:47K ohms. grammable option) and latches on steady red to indicate alarm. Temperature range: 32°F to 120°F(0°C to 49°C). The FMM-1(A) Monitor Module is intended for use in intelli- Humidity range: 10%to 93%noncondensing. gent, two-wire systems, where the individual address of each Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built-in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x vides either a two-wire or four-wire fault-tolerant Initiating 2 125" (5.398 cm)deep box. Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class DN-6720:C•10/06/2010—Page 1 of 4 FMM-101(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65"(1.651 cm)deep. • Built-in type identification automatically identifies this device as a monitor module to the panel. Wire length: 6" (15.24 cm) minimum. • Powered directly by two-wire SLC loop. No additional power required. FZM-1(A) Interface Module • High noise(EMF/RFI) immunity. • Supports compatible two-wire smoke detectors. • Tinned, stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 – 159 on FlashScan loops; source. 01 –99 on CLIP loops. • High noise(EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. 3 14?5 0 � AD� 0 � • Direct-dial entry of address: 01 –159 on FlashScan loops, � 13 ' --�� 2 2 01 –99 on CLIP loops. � 12� � 3 LOOP 3 • LED flashes during normal operation;this is a programma- � 11 � 4 � 4 ble option. 10 5 � 5 • LED latches steady to indicate alarm on command from 9 $ � 6 9 g 7 6 control panel. TENS ONES n The FZM-1(A) Interface Module is intended for use in intelli- 11 gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This � � module allows intelligent panels to interface and monitor two- Y wire conventional smoke detectors. It transmits the status(nor- � � �W Q mal, open, or alarm)of one full zone of conventional detectors � � � m back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. . FZM-1(A) APPLICATIONS The FMM-101(A) Mini Monitor Module can be installed in a Use the FZM-1(A)to monitor a zone of two-wire smoke detec- single-gang junction directly behind the monitored unit. Its tors. The monitored circuit may be wired as an NFPA Style B small size and light weight allow it to be installed without rigid (Class B)or Style D (Class A) Initiating Device Circuit.A 3.9 K mounting. The FMM-101(A) is intended for use in intelligent, ohm End-of-Line Resistor(provided)terminates the end of the two-wire systems where the individual address of each module Style B or D (class B or A) circuit (maximum IDC loop resis- is selected using rotary switches. It provides a two-wire initiat- tance is 25 ohms). Install ELR across terminals 8 and 9 for ing device circuit for normally-open-contact fire alarm and Style D application. security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FZM-1(A)OPERATION FMM-101(A)APPLICATIONS Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control Use to monitor a single device or a zone of four-wire smoke panel and reports its type and the status (open/normal/short) detectors,manual fire alarm pull stations,waterflow devices,or of its Initiating Device Circuit (IDC). A flashing LED indicates other normally-open dry-contact devices. May also be used to that the module is in communication with the control panel. monitor normally-open supervisory devices with special super- The LED latches steady on alarm (subject to current limita- visory indication at the control panel. Monitored circuiUdevice tions on the loop). is wired as an NFPA Style B(Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPECIFICATIONS cuit. Nominal operating voltage: 15 to 32 VDC. FMM-101(A)OPERATION Maximum current draw:5.1 mA(LED on). Each FMM-101(A) uses one of the available module Maximum IDC wiring resistance:25 ohms. addresses on an SLC loop. It responds to regular polls from Average operating current: 300 NA, 1 communication and 1 the control panel and reports its type and the status(open/nor- LED flash every 5 seconds,3.9k eol. mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Average operating current: 350 �aA, 1 communication every maximum. Current: 90 mA per module maximum. 5 seconds, 47k EOL; 600 uA Max. (Communicating, IDC Temperature range: 32°F to 120°F(0°C to 49°C). Shorted). Humidity range: 10%to 93%noncondensing. Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Voltage: 11 Volts. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Current:400�A. 2.125" (5.398 cm)deep box. EOL resistance:47K ohms. Temperature range;32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6720:C•10/06/2010 FDM1(A� Dl1aI MOIIItOP MO�Il1I@ —161.002/23/3(AFP-200: FMM-1/-101, FZM-1) The FDM-1(A) Dual Monitor Module is intended for use in intelli- —161.002/42/1 (NFS-640: FMM-1/-101) gent, two-wire systems. It provides two independent two-wire • Lloyd's Register: initiating device circuits (IDCs) at two separate, consecutive —03/60011/E1 (FMM-1/-101, FZM-1) addresses. It is capable of monitoring normally open contact fire _g4/60004/E2(AFP-200:except FDM-1) alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- —02/60007(NFS-640: FDM-1) controlled LED. • FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 NOTE:The FDM-1(A) provides two Style B (Class B) IDC circuits (NFS2-3030) ONLY. Style D (Class A) IDC circuits are NOT supported in any appi��at�on. Product Line Information FDM-1(A)SPECIFICATIONS NOTE:"A"suffix indicates ULC-Iisted model. Normal operating voltage range: 15 to 32 VDC. FMM-1(A): Monitor module. Maximum current draw:6.4 mA(LED on). FMM-101(A): Monitor module, miniature. Average operating current: 750 NA(LED flashing). FZM-1(A): Monitor module,two-wire detectors. Maximum IDC wiring resistance: 1,500 ohms. FDM-1(A): Monitor module,dual,two independent Class B cir- Maximum IDC Voltage: 11 Volts. cuits. Maximum IDC Current:240�A SMB500: Optional surface-mount backbox. EOL resistance:47K ohms. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box.They may also be mounted to the SM6500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:0219 • MEA:457-99-E • U.S.Coast Guard: DN-6720:C•10/06/2010—Page 3 of 4 FlashScanOO and NOTIFIEROO are registered trademarks and FireWatchT"^is a trademark of Honeywell International Inc. �02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6720:C•10/06/2010 DN-6726:D•H-240 NBG-12LX (� NOTI FI E R° Addressable Manual Pull Station � by Honeywell - - - , - - °General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., � requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the �� alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady � red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to The NBG-12LX SLC loop(accepts up to 12 AWG/3.25 mmz wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- Addressable Manual Pull Station flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4" (10.16 cm)square electrical box. �nstallation • Smooth dual-action design. The NBG-12LX will mount semi-flush into a single-gang, dou- • Meets ADAAG controls and operating mechanisms guide- ble-gang, or standard 4" (10.16 cm) square electrical outlet lines (Section 4.1.3[13]); meets ADA requirement for 5 Ib. box, or will surface mount to the model SB-10 or SB-I/O sur- maximum activation force. face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The • Highly visible. BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. �peration • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position. Once latched, the word "ACTI- Boxes. VATED" (in bright yellow) appears at the top of the handle, • Up to 99 NBG-12LX stations per loop on CLIP protocol `Nhile a portion of the handle protrudes from the bottom of the loops. station.To reset the station, simply unlock the station with the Up to 159 NBG-12LX stations per loop on FlashScanO pro- key and pull the door open.This action resets the handle;clos- � ing the door automatically resets the switch. tocolloops. • Dual-color LED blinks green to indicate normal on Each manual station, on command from the control panel, FlashScanOO systems. sends data to the panel representing the state of the manual switch.Two rotary decimal switches allow address settings Construction (1 —159 on FlashScanOO systems, 1 —99 on CLIP systems). Shell, door, and handle are molded of durable polycarbonate Architectural/Engineering material with a textured finish. $pecifications Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so • Shipping Weight: 9.6 oz. (272.15 g) designed that after actual Emergency Operation, they cannot • Normal operating voltage:24 VDC. be restored to normal except by use of a key.An operated sta- • Maximum SLC loop voltage:28.0 VDC. tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of • Maximum SLC standby current: 375�A. red-colored polycarbonate material with clearly visible operat- • Maximum SLC alarm current:5 mA. ing instructions provided on the cover. The word FIRE shall • Temperature Range:32°F to 120°F(0°C to 49°C) appear on the front of the stations in white letters, 1.00 inches Relative Humidity: 10%to 93%(noncondensing) (2•54 cm) or larger. Stations shall be suitable for surface � mounting on matching backbox SB-10 or SB-I/O;or semi-flush • For use indoors in a dry location mounting on a standard single-gang, double-gang, or DN-6726:D•4/13/2012—Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. NY-Piate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM: 7150-0028:0199. • FDNY: COA#6085(NFS2-640), COA#6098(NFS2-3030). • BSMI:C1313066760047. • U.S.Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO and FlashScanO are registered trademarks of Honeywell International Inc. �02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. EN6INEERIN6 8 MANUFACTURIN& All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6726:D•4/13/2012 DN-7087:C1 SpectrAlert� Advance N OT 1 F 1 E R° Selectable Output �� Notification Appliances by Honeywell � . .�_ � - - General � _ System SensorOO SpectrAlertOO Advance selectable-output horns, strobes and horn/strobes are rich with features guaran- �, �='�'F• - teed to cut installation times and maximize profits. The Spec- � � trAlert Advance series of notification appliances is designed to �` �„ simplify your installations, with features such as: plug-in � designs, instant feedback messages to ensure correct installa- Indoor Ceiling Outdoor Ceiling tion of individual devices, and eleven field-selectable candela Horn/Strobe Strobe settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first °� �- attach a universal mounting plate to a four-inch square, four- ;�_r��rw �;p� inch octagon, or double-gang junction box. The two-wire �_!'� � ' mounting plate attaches to a single-gang junction box. - "- � � �' �" � Then, connect the notification appliance circuit wiring to the � - �'� SEMS terminals on the mounting plate. Indoor Wall Indoor Ceiling Finally, attach the horn, strobe, or horn/strobe to the mounting Horn/Strobe Strobe plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will ��° ,. temporarily hold in place with a catch until it is secured with a - �-'' captured mounting screw. • SpectrAlert Advance products allow you to choose: r • 12 or 24 volts. Indoor Wall Outdoor Wall^ • 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 can- Horn Strobe dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from-40°F and 151°F (-40°C and ing window. 66°C). • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and • The SpectrAlert Advance series includes outdoor notifica- Weatherproof per NEMA 4X, IP56 tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox. wire and four-wire) are available for wall or ceiling. Outdoor • Horn rated at 88+dbA at 16 volts. horns are available for wall only.All System Sensor outdoor . Rotary switch for tone selection. products are rated between -40°F and 151°F (-40°C and 66°C) in wet or dry applications. • Three horn volume settings. Models available: • Electrically compatible with existing SpectrAlert products. • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire Engineering Specifications horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAlert Advance horns, strobes, and horn/strobes shall horn/strobe. mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- cm) backbox,4.0" (10.16 cm)octagonal backbox, or a double- • wire horn/strobe. gang backbox.Two-wire products shall also mount to a single- gang 2.0"x 4.0"x 1.875" (5.08 x 10.16 x 4.763 cm)backbox.A • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling horn/strobe. and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- Features trAlert Advance products, when used with the Sync•CircuitT"' Plug-in design. Module accessory, shall be powered from a non-coded notifi- � cation appliance circuit output and shall operate on a nominal • Same mounting plate for wall-and ceiling-mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12- • Shorting spring on mounting plate for continuity check volt rated notification appliance circuit outputs shall operate before installation. between 9 and 17.5 volts; 24-volt rated notification appliance • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and • Tamper-resistance capability. 120°F (0°C and 49°C)from a regulated DC, or full-wave-recti- • Field-selectable candela settings on wall and ceiling units: fied, unfiltered power supply. Strobes and horn/strobes shall 15, 15/75,30,75, 95, 110, 115, 135, 150, 177, 185. have field-selectable candela settings including 15, 15/75, 30, • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95, 110, 115, 135, 150, 177, 185. 75 candela. • Outdoor wall and ceiling products. DN-7087:C1 •11/9/11—Page 1 of 4 STROBE Operating Specifications The strobe shall be a System Sensor SpectrAlert Advance . Standard operating temperature: 32°F to 120°F (0°C to Model listed to UL 1971 and shall be approved for fire 49oC� protective service.The strobe shall be wired as a primary-sig- K Series operating temperature: —40°F to 151°F (-40°C naling notification appliance and comply with the Americans � to 66°C). with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- • Humidity range: 10% to 93% non-condensing (indoor age range.The strobe light shall consist of a xenon flash tube products). and associated lens/reflector system. • Strobe flash rate: 1 flash per second. HORN/STROBE COMBINATION • Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a The horn/strobe shall be a System Sensor SpectrAlert non-regulated, time-varying power source that is used on Advance Model listed to UL 1971 and UL 464 and some power supply and panel outputs. shall be approved for fire protective service. The horn/strobe � pperating voltage range: 8 V to 17.5 V(12 V nominal);or shall be wired as a primary-signaling notification appliance 16 V to 33 V(24 V nominal). NOTE: P, S, PC,and SC prod- and comply with the Americans with Disabilities Act require- ucts will operate at 12 V nominal only for 15 cd and 15/75 ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall cd. consist of a xenon flash tube and associated lens/reflector sys- • Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 tem.The horn shall have three audibility options and an option mmz). to switch between a Temporal 3 pattern and a Non-Temporal • Ceiling-mount dimensions (including lens): 6.8" diame- (continuous) pattern.These options are set by a multiple posi- ter x 2.5"deep(17.3 cm diameter x 6.4 cm deep). tion switch.On four-wire products,the strobe shall be powered . N/all-mount dimensions(including lens):5.6" H x 4.7"W independently of the sounder.The horn on horn/strobe models x 2.5" D(14.2 cm H x 11.9 cm W x 6.4 cm D). shall operate on a coded or non-coded power supply. • Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x OUTDOOR PRODUCTS 11.9 cm W x 3.3 cm D). SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate Agency Listings and Approvals between —40°F and 151°F (-40°C and 66°C). The products The listings and approvals below apply to SpectrAlert Advance shall be listed for use with a System Sensor outdoor/weather- Selectable Output Notification Devices. In some cases,certain proof backbox with half-inch and three-fourths-inch conduit modules may not be listed by certain approval agencies, or entries. listing may be in process. Consult factory for latest listing sta- SYNCHRONIZATION MODULE tus. The module shall be a System Sensor Sync•Circuit MDL3R or ' UL Listed: S4011 (HR_, HW_, P2_, P4_, PC2_, MDL3W listed to UL 464 and shall be approved for fire protec- PC4_ models); S5512 (models SCR, SCRH, SCW, tive service.The module shall synchronize SpectrAlert strobes SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, at 1 Hz and horns at Temporal 3. Also, while operating the SRHK,SRK). strobes, the module shall silence the horns on horn/strobe • ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models over a single pair of wires. The module shall mount to models, with exception of outdoor strobes). See Canadian a 4.688"x 4.688"x 2.125" (11.906 x 11.906 x 5.398 cm)back- data sheet for listings and specifications. box. The module shall also control two Style Y (class B) cir- . FM approved cuits or one Style Z (Class A) circuit. The module shall MEA:452-05-E synchronize multiple zones. Daisy-chaining two or more syn- � chronization modules together will synchronize all the zones • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, they control. The module shall not operate on a coded power SRH, SW, SWH);7300-1653:0188(P2_, P4_, PC2_, PC4_ supply. modules); 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187(SCRHK, SCRK, SRHK,SRK). Strobe Current Draw, Horn Current Draw, UL Maximum (mA RMS) UL Maximum (mA RMS) 8-17.5V 16-33V Sound $-17.5V 16-33V Candela Pattern dB DC FWR DC FWR DC FWR DC FWR 15 123 128 66 71 Temporal High 57 55 69 75 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Standard 30 NA N/A 94 96 Temporal Low 38 44 44 48 Candela 75 NA NA 158 153 Non-temporal High 57 56 69 75 Range g5 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 135 NA NA 228 207 Coded Medium 44 51 56 69 High 150 NA NA 246 220 Coded Low 40 46 52 50 Candela Range 177 NA NA 281 251 185 NA NA 286 258 Page 2 of 4—DN-7087:C1•11/9/11 Horn and Horn/Strobe Horn and Horn/Strobe Output (dBA) Rotary Switch Setting 8-17.5V 16-33V Setting Repetition Rate dB Level Switch Sound dB Position Pattern DC FW DC FW 1 Temporal horn High R R 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7' Externally coded High 6 Non-temporal Low 75 75 81 81 8' Externally coded Medium 7" Coded High 82 82 88 88 9' Externally coded Low 8" Coded Medium 78 78 85 85 "NOTE:Settings 7, 8, and 9 are not available 9" Coded Low 75 75 81 81 on 2-wire horn/strobe. *NOTE:Settings 7, 8, and 9 are not available on 2-wire horn/strobe. 7tivo-Wire Horn/Strobe, STANDARDCandela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern, dB $-17.5 V 16—33 V Level 15 15/75 15 15/75 30 75 95 110 115 DC Input,Temporal, High 137 147 79 90 107 176 194 212 218 DC Input,Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input,Temporal, Low 132 143 66 77 93 154 179 198 207 DC Input,Non-temporal, High 141 152 91 100 116 176 201 221 229 DC Input,Non-temporal, Medium 133 145 75 85 102 163 187 207 216 DC Input,Non-temporal,Low 131 144 68 79 96 156 182 201 210 FWR Input,Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input,Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input,Temporal,Low 129 151 76 86 101 160 184 194 201 FWR Input, Non-temporal, High 142 161 103 112 126 181 203 221 229 FWR Input, Non-temporal,Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non-temporal,Low 132 154 80 90 105 161 184 202 211 Two-Wire Horn/Strobe, H/GHCandela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS) 16-33V 16-33V DC Input FWR Input 135 150 177 185 135 150 177 185 DC,Temporal, High 245 259 290 297 FWR,Temporal, High 215 231 258 265 DC,Temporal, Medium 235 253 288 297 FWR,Temporal, Medium 209 224 250 258 DC,Temporal, Low 232 251 282 292 FWR,Temporal,Low 207 221 248 256 DC, Non-temporal, High 255 270 303 309 FWR, Non-temporal, High 233 248 275 281 DC, Non-temporal,Medium 242 259 293 299 FWR, Non-temporal,Medium 219 232 262 267 DC, Non-temporal,Low 238 254 291 295 FWR, Non-temporal,Low 214 229 256 262 7087dim12009.tif �" � 6.8„ � � � � � 2.5 5.6" � � � � I I�2.5„ DN-7087:C1 •11/9/11—Page 3 of 4 Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe,standard cd,red. PC2R 2-wire horn/strobe,standard cd, red. P2RH 2-wire horn/strobe,high cd,red. PC2RH 2-wire horn/strobe,high cd,red. P2RK 2-wire horn/strobe,standard cd,red,outdoor. PC2RK 2-wire horn/strobe,standard cd,red,outdoor. P2RHK 2-wire horn/strobe,high cd,red,outdoor. PC2RHK 2-wire horn/strobe,high cd,red,outdoor. P2W 2-wire horn/strobe,standard cd,white. PC2W 2-wire horn/strobe,standard cd,white. P2WH 2-wire horn/strobe,high cd,white. PC2WH 2-wire horn/strobe, high cd,white. P4R 4-wire horn/strobe,standard cd,red. PC4R 4-wire horn/strobe,standard cd,red. P4RH 4-wire horn/strobe,high cd,red. PC4RH 4-wire horn/strobe, high cd,red. P4RK 4-wire horn/strobe,standard cd,red,outdoor. PC4RK 4-wire horn/strobe,standard cd,red,outdoor. P4RHK 4-wire horn/strobe,high cd,red,outdoor. PC4RHK 4-wire horn/strobe,high cd,red,outdoor. P4W 4-wire horn/strobe,standard cd,white. PC4W 4-wire horn/strobe,standard cd,white. P4WH 4-wire horn/strobe,high cd,white. PC4WH 4-wire horn/strobe, high cd,white. WALL STROBES CEILING STROBES SR Strobe,standard cd,red. SCR Strobe,standard cd,red. SRH Strobe,high cd,red. SCRH Strobe,high cd,red. SRK Strobe,standard cd,red,outdoor. SCRK Strobe,standard cd,red,outdoor. SRHK Strobe,high cd,red,outdoor. SCRHK Strobe,high cd, red,outdoor. SW Strobe,standard cd,white. SCW Strobe,standard cd,white. SWH Strobe,high cd,white. SCWH Strobe,high cd,white. A CCESSOR/ES HORNS BBS-2A Backbox skirt,wall, red. HR Horn, red. BBSW-2A Backbox skirt,wall,white. HRK Horn, red,outdoor. BBSC-2A Backbox skirt,ceiling,red. HW Horn,white. BBSCW-2A Backbox skirt,ceiling,white. ACCESSORIES,continued SA-WBB Weatherproof backbox,wall. TR-HS Trim Ring,wall,red,package of 5 SA-WBBC Weatherproof backbox,ceiling. TRW-HS Trim Ring,wall,white, package of 5 WTP Weatherproof,flush mount plate,red TRC-HS Trim Ring,ceiling,red,package of 5 WTPW Weatherproof,flush mount plate,white TRCW-HS Trim Ring,ceiling,white, package of 5 NOTE: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd" refers to strobes that include 15, 15/75,30,75,95, 110,and 115 candela settings. NOTE: For strobes and horn/strobes,add suffix"F"for French or"B"for Bilingual. NOTE: All outdoor models("K(A)"suffix)include a plastic weatherproof backbox. NOTE: Add"-R"to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. NOTE: Add"P"to model for plain housing. (No"FIRE"marking on cover.) Sync•CircuitTM is a trademark and NOTIFIEROO and SpectrAlertOO are registered trademarks of Honeywell International Inc. �02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-7087:C1•11/9/11 0 S�• � S� � �� � U � L LISTED :.--- �. � - Terminal Cabinet � � � .� The IFX "FIRE ALARM TERMINAL CABINET" offers � easy identification of fire alarm wiring junctions for " '� troubleshooting and maintenance of system wiring. Highly visible 2" lettering and a removable "lift-a way" hinged door contribute to fast location and easy access. This surFace mount cabinet is fabricated from 16 gauge steel with a durable, baked on, red textured powder coat finish. The IFX includes a high security CAT 30 keyed door lock and is UL listed for life safety. The IFX is supplied with the SAE Tool-Less terminal blocks, saving you time and effort in your installation. Testing the Standard Features: circuits can be accomplished with the use of the TTS Test •Available in size A or D Probe in the individual test ports. • 16 gauge steel construction • Durable red textured finish • White 2" indelible lettering "Fire Alarm Terminal Cabinet" When properly installed, there will • Lift-a way hinge with CAT 30 keyed be no conductors exposed.All dOOr IOCk circuit testing can be performed via • Interior labeling of terminal strips the individual test ports per circuit. • Field identification labels inside cover ' i' • 1/2", 3/4", 1", 1 1/2" and 2" EMT � � knockout clusters ` � y ,� • Sace Age TTS Toolless terminal strips � ,�,�'�,., , • Terminal points rated for 20 - 12 gauge wire '� • �,,,�'�,� '� t • Terminal strips rated for 20 amp max 250V �'r'r,, '� (Class B/UL) 300V (CSA) � '� ,- ,- ISO 9001 Opt1011S: REGISTERED • Custom finish � COMPANY • Custom legend � N�,q ACE �s I Space Age Electronics, inc. #,����� �� � www.1SAE.com \.� �����~ ADA Made In U.S.A. 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0417 LT10424 Rev.A 1/2 No Excuses, .lust Solutions! �SPACEAGE ELECTRONICS, INC. Description: The IFX Terminal Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and finished with a durable red textured, heat-resistant baked-on enamel finish. The front cover displays "FIRE ALARM TERMINAL CABINET" in 2" white indelible screened lettering and features a removable formed lift-a- way hinge and a high security CAT 30 keyed door lock. The interior of the box contains field identifica- tion labels on the inside cover corresponding to the terminal strip's labeling inside the back box. The cabinet employs SAE TTS Tool less terminal strips rated for 12 gauge wire and 20 amp max 250V (Class B/UL) 300V (CSA). The dual barrier terminal strips are mounted on a durable 18 GA cold rolled steel galvanize finish backboard and secured to the back box. Custom finish and legend available. The cabinet includes embedded 1/2", 3/4", 1", 1 1/2" and 2" EMT knockout clusters. Size # of Terminal Points Overall Dimensions of Cabinet W H D Cubic Inches A 64 23 1/2" 13" 5 1/2" 1582.00" D 128 23 1/2" 23 1/2" 5 1/2" 2813.78" 1/2" mounting screw D Back Plate clearance from back Detail plate to back box. —drill screw FI RE ALARM back �\(self-tapping) plate TERMINAL ° " CA61 N ET 1'2�� t ♦ back box � Removable formed I — � lift-a-way hinge I'— W � � + �: Cr � � � � � � 0 Ordering Information: ��==�, ; ' � =� ,,�= Part # Description ,% SSU00661 IFXA 64 Point Terminal Cabinet SSU00663 IFXD 128 Point Terminal Cabinet Agency Approvals: UOXX.S2580 UL Listed Control Unit Accessories Optional Accessories: SAE 's Tooless Terminal Strip PN Description � � � Included in IFX ( = Space Age Electronics, inc. SSU00470 TTS Black s � • Q . � • www.1SAE.com SSU00471 TTS White � 800.486.1723 Toll Free Sold Separately ��i—_�^`, f4 508.485.0966 Local SSU00472 TTS Test Probe �' — 508.485.4740 Fax - This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, .lust Solutions! ED0417 LT10424 Rev.A 2/2