HomeMy WebLinkAboutB12-0309 REV20 CR2 Plans.pdf O CV CO r 00 MDP EM PANEL MECH PANEL o PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT: FIRE STATION#2 ENGINEER: CTL PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W PROJECT#: 12017 VOLTAGE: 120/208V, 3P,4W C) 8 O ") MOUNTING: SURFACE MAINS: 600A MLO MOUNTING: SURFACE MAINS: 100A MLO MOUNTING: SURFACE MAINS: 200A MLO O U CO TYPE: AIC: 10K TYPE: AIC: 10K TYPE: AIC: 10K (ll 0 0O PHASE PHASE PHASE PHASE PHASE PHASE U) U) DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION ® - EM PANEL 11192 100 3 1 2 3 200 11573 DORM A& B PANELS BOILER 250 20 1 1 2 1 20 1200 GARAGE 'RED' LIGHTING CH-1 2750 40 2 1 2 1 20 500 B-2 0 0- ¢ ~ 11192 3 4 11573 P-1 46 1 20 2 3 14 1 20 250 UP STAIRS 'RED' LIGHTING 2750 3 4 2 20 1 450 1 P-2 Q -0 11192 15 6 1 11573 46 5 16 1 20 1 250 UP STAIRS 'RED' LIGHTING CH-1 1200 20 3 5 6 450 (D_ N M 0 GARAGE A& B PANELS 7506 200 3 17 8 3 100 9713 EHU A PANEL P-4 45 20 1 7 8 1 20 10 RED LIGHT PUSH BUTTONS 1200 17 18 2 20 450 P-3 (D LL 1. 7506 9 10 9713 FAN COILS 1250 20 1 9 10 1 20 800 FRIDGE 1200 9 10 450 .� z U U) •(� " 7506 11 12 9713 OFFICE OUTLETS 360 20 1 11 12 1 20 720 GARAGE OUTLETS UH-3 500 20 2 11 12 1 20 900 P-5 O) U �O MECH PANEL 11780 200 3 13 14 3 100 9590 EHU B PANEL OFFICE OUTLETS 360 20 11 13 14 1 20 500 OFFICE LIGHTS 500 13 14 2 120 450 P-6 Q N N 6 11780 15 16 9590 OFFICE OUTLETS 540 20 1 15 16 1 20 500 AIR FILL STATION UH-3 500 20 2 15 16 450 '� L0 11780 0600 11780 117 18 9590 OFFICE OUTLETS 900 20 1 17 18 2 180 5500 AIR COMPRESSOR 500 17 18 2 20 450 P-7 U ® O 00 SPACE 0 119 20 3 100 0 TVSS MECH OUTLETS 360 20 1 19 20 1 5500 11 EF-2 50 20 1 119 20 450 .1 C: LLI SPACE 0 21 22 0 UH-1 375 20 2 21 22 1 20 750 TRUCK POWER RV-1 0 2 1 2 22 1 20 150 GF-1,2,3 w J LLJ 2 O SPACE 0 23 24 0 375 23 24 1 20 750 TRUCK POWER AFC-4 250 20 1 23 4 2 20 1000 UH-2 I� SPACE 0 25 26 0 SPACE LOWER LVL IT RM 500 20 1 25 26 1 20 750 GARAGE DOOR 26 1000 � LJJ }' � O SPACE 0 27 28 0 SPACE LOWER LVL IT RM 500 20 1 27 28 1 20 750 GARAGE DOOR HEAT TRACE (30mA GFI) 1750 30 2 27 28 2 20 375 UH-1 -co SPACE 0 29 30 0 SPACE GARAGE RADIANT 750 20 1 29 30 1 20 750 GARAGE DOOR 1750 29 30 375 V U U C:) O Cie d% SPACE 0 31 32 0 SPACE PHONE 250 20 1 31 32 2 30 600 IT EQUIPMENT HEAT TRACE (30mA GFI) 1750 30 2 31 32 2 20 375 UH-1 � ate- 05 s SPACE 0 33 34 0 SPACE UPSTAIRS LIGHTS 500 20 1 33 34 1600 1750 33 34 375 -r-+ O SPACE 0 35 36 0 SPACE GARAGE LIGHTS 1500 20 1 35 36 1 20 500 ITANTENNA HEAT TRACE (30mA GFI) 1750 30 2 35 136 2 20 375 UH-1 � U 6j SPACE 0 37 38 0 SPACE BLOCK HEATER 500 20 1 37 38 3 20 833 ENGINE EXHAUST 1750 37 38 375 (, 2i Q 00 SPACE 0 39 40 0 SPACE GENERATOR ANNUNCIATOR 500 20 1 39 40 833 HEAT TRACE (30mA GFI) 1750 1 30 2 39 40 1 20 250 FC-1 L- 00 SPACE 0 41 42 10 SPACE GEN. BATT. CHARGER 1500 20 1 41 42 833 11750 41 42 1 20 250 FC-5 Q X O m LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY O IZ CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: 0.94 0.91 0.85 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING 20247 56 20247 56 LIGHTING 4200 12 4200 12 LIGHTING 0 0 0 0 Q0 REG/8 RECEPTACLES 49740 138 29870 83 RECEPTACLES 9690 27 9690 27 RECEPTACLES 0 0 0 0 p 0 H,1 � MECHANICAL 62777 174 71612 198 MECHANICAL 18887 52 21637 60 MECHANICAL 35340 98 36715 102 KITCHEN 51300 142 33345 92 KITCHEN 800 2 520 1 KITCHEN 0 0 0 0 TOTAL 184064 510 155074 430 TOTAL 33577 93 36047 100 TOTAL 35340 98 36715 102 j � X57 � A`S'S/ONAI. N�. VOLTAGE DROP CALCULATIONS VAIL FIRE STATION #2 VD= 2*(Length)*(Resistance/kFT)*(Current) Demand Load Calculations (Sets of Cond's)*(1000) (Per NEC Article 220 Parts 1-III) ■ XFMR to CT - 3 Sets #400 MCM Al CN Initial Voltage(V): 208 Quantity Volt-Amps Demand Total (VA) Current(A): 600 Lighting 14� Length(ft): 80 Fire Station Lighting IECC 2009 6422 SF X 1 .00 X 100% = 6422 Sets of Conductors: 3 g g ( ) Receptacles Resistance(Ohms/kFT): 0.059 Commercial Areas Rec 6422 SF X 1 .0 = 6422 VA Voltage Drop(V): 1.64 IT Equipment/Computers 15 EA X 1500.0 = 22500 z O Voltage(V). 206.36 Radio Equipment 5 EA X 1200.0 - 6000 _ %VD: 0.79% Truck Connections 3 EA X 1500.0 = 4500 0 O CT to MDP -3 Sets #250 MCM Al Receptacle Total 1 LS X 34922 VA ~LO Initial Voltage(V): 206.36 1 st 10 kVA Receptacle Load at 100% 1 LS X 10000 X 100% = 10000 Current(A): 600 >10 kVA Recet p acle Load at 50% 1 LS X 24922 X 50% = 12461 r Length(ft): 90 Kitchen Equipment CIO GENERATOR EG-1 : Sets of Conductors: 3 Range 3 EA X 1500 X 65% = 2925 Uj O Resistance(Ohms/kFT): 0.066 Microwave 3 EA X 1200 X 65% = 2340 U) > PROVIDE 208V 3-PHASE 35KW DIESEL GENERATOR, CUMMINS MODEL DGBB. Voltage Drop: 2.38 Disposal 3 EA X 1500 X 65% = 2925 2i 0 PROVIDE 70 GAL SUB-BASE FUEL TANK FOR APPROXIMATELY 24 HOURS Refrigerator 5 EA X 1500 X 65% = 4875 WORTH OF FUEL. PROVIDE 3-POLE 100A TRANSFER SWITCH AS WELL AS Voltage(V): 203.99 _ 0 ANNUNCIATOR, BATTERY CHARGER, AND ALL REQUIRED ACCESSORIES. Dishwasher 4 EA X 1500 X 65% - 3900 J %VD: 1.93% Misc Appliances 8 EA X 1500 X 65% = 7800 MDP to EM Panel- 1 Set#1/0 Al Laundry Equipment Z (FUTURE) Initial Voltage(V): 203.99 Washer 1 EA X 1500 X 100% = 1500 EM MECH GARAGE A GARAGE B DORM A DORM B EHU A EHU B Current(A): 100 Dryer 1 EA X 500 X 100% = 500 Uj 0 PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL U. EG- � 100/3 � Length(ft): 90 Electric Heating Equipment - Sets of Conductors: 1 Unit Heaters 4 EA X 1500 X 100% - 6000 Uj I Resistance(Ohms/kFT): 0.2 Elec Baseboard 16 LF X 250 X 100% = 4000 J Voltage Drop: 3.60 Mechanical Equipment Voltage(V): 200.39 Garage Engine Exhaust 1 EA X 2000 X 100% = 2000 9,400 AIC 20,000 AIC 14,700 AIC 14,700 AIC 11,500 AIC 11,500 AIC %VD: 3.66% Garage Supply Fan 1 EA X 2000 X 100% = 2000 Q PROVIDE SHORTEST RUN Garage Doors 3 EA X 1000 X 100% = 3000 N JATLjPOSSIBLE, MINIMIZE THE Co-ray-vac Fan 1 EA X 2000 X 1000 = 2000 > NUMBER OF CONDUCTOR BENDS. Air Compressor 1 EA X 11400 X 100% = 11400 100/3 DO NOT INSTALL TVSS WITHIN Condensing Units 5 EA X 4000 X 100% = 20000 TRANSFER ELECTRICAL EQUIPMENT. SWITCH Fan Coils 5 EA X 1500 X 100% = 7500 TVSS Exhaust Fans 10 EA X 100 X 100% = 1000 (4#1 CU, 1#8CUG)3"C OR (4#2 CU, #2G)2"C CURRENT TECHNOLOGY Pumps 8 EA X 1200 X 100% = 9600 AEC PROJECT #: 12017(4#1/0 AL, 1#6ALG)4"C #CG200-208 Boilers 2 EA X 500 X 100% = 1000 (4#3/0 CU, 1#6CUG)4"C OR Add'I 25% of Max Motor Load 1 EA X 10000 X 25% = 2500 DATE: ISSUE: (4#250MCM AL, 1#4ALG)4"C (1)SPARE 4"C TOTAL 127648 20,900 AIC 12-19-12 DRYER VENT REV. �g M 12-19-12 RFC #067 A- , 208V, 3-Phase, 4 Wire Service 127648 (VA) / 361 = 354 AMPS 01-02-13 REVISION #11 11 57,400 AIC 23,000 AIC 02-06-13 ASI # 015 100/3 200/3 200/3 200/3 100/3 100/3 100/3 �2)200A 03-07-13 ASI # 016 1 r � I I I I PACES l 3[(4#400 MCM AL)4"C] 1 1 600/3 1 1 l 03-25-13 ASI #016 REVISION 1 Drawn By: Checked By: UTILITY CTL AEC TRANSFORMER MAIN DISTRIBUTION PANEL "MDP" PAD MOUNTED LOCATE EXTERIOR, 600A 120/208V 3P 4W NE-LINE, ADJACENT TO METER/CT. > > > 42kAIC PANELS & ELECTRICAL ONE-LINE DIAGRAM_ LOAD CALCS NO SCALE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED SCALE: NONE AT ONE-LINE, NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION ACCEPTABLE, SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW. RECEIVED By David Rhoades at 10:19 am, Apr 11, 2013 • 2 of 10 ®COPYRIGHT 2005 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. � o N A B C STORAGE U g tn wP 0 c) I I 128 I cn ) GFI � � .,� 7 77 77 Cti SHEET DETAIL NOTES: o 0) o Q 1 PROVIDE CONNECTION AT CEILING FOR TRUCK POWER. COORDINATE ____--- Q O LOCATION WITH OWNER PRIOR TO ROUGH-IN. N X O �- -r- -i -r-r- - ---- -T----i- r- -i-- -r-� I I I I I I I I I I I I I I I I I I 1 -0 O2 PROVIDE LOW VOLTAGE CONNECTION FOR ANY AUTOMATIC TOILETS O3 UP I I _ I I =l I I I I I I I I I = I I I X I i }J' Q N I I I I I I I z i }n OR SINKS. COORDINATE LOCATION OF CONNECTION WITH PLUMBER GARAGEA-5 V N PRIOR TO ROUGH-IN. STAIR 06 PROVIDE MOTOR-ACTUATED DAMPER FOR GENERATOR. INTERLOCK - _ _ _ _ _ _ _ _ _ _ 121 C: ° ` � ACTUATOR WITH GENERATOR RADIATOR FAN. •U W O4 COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH I ' DN TO ' MECH-24,26 MECHANICAL CONTRACTOR PRIOR TO CONSTRUCTION. < UPSTA S WP WID O5 MAINTAIN EXISTING FIBER OPTIC CONNECTION. DO NOT DISTURB ' I 2H GFI GFI w Q ENTRY IN ANY WAY, THE FIBER OPTIC CABLE SERVES OTHER - J - = i I �"' U O o C: BUILDINGS NEARBY. i HAND (� •E U 0p O i J GFI DRYER � GARAGE J HAND GARAGE A-41 ® N OLOCATE POWER CONNECTION IN CEILING FOR WIRELESS INTERNET, 2 A-18 DRYER PARTIAL U _ COORDINATE LOCATION WITH OWNERS PRIOR TO ROUGH-IN. I vv%jlWl"1'4 2 O Q O EM-13 HOSE DRY 'ry' GARAGE GARAGE GARAGE J i N ~ EM-11 EM-13 X O7 PROVIDE DISCONNECT SWITCH ON BACK WALL FOR AIR ® Q COMPRESSOR. COORDINATE EXACT LOCATION WITH OWNERS PRIOR PARTIAL A-39 A-2o i 14 I- TO ROUGH-IN. 112 113 _� —\� O m OFFICE FACP -� UH KIOSK _ 2 O O8 PROVIDE JUNCTION BOX AT EDGE OF MEZZANINE FLOOR TO CONNECT 2 J TO THE AIR FILL STATION. COORDINATE EQUIPMENT CONNECTION I \ WITH OWNERS PRIOR TO ROUGH-IN. 110 I MECH-36,381 II M TO I GARAGE A / GFI 2 F JO GARAGE A-3 0 t4 O II W AIII I PANEL PARTIAL GFI O GENERAL NOTES: AA O RAGE EM-15® PMRTI L1 GARAGEB 2 2 HRV M I° h 6 ® V J PANEL J J TO 1. ALL GFCI AND WATERPROOF-GFCI RECEPTACLES SHALL BE PROVIDED I - ME - ,: ti WITH METALLIC JUNCTION BOXES AND COVERS. PROVIDE METALLIC JUNCTION BOXES TO ENSURE PROPER GROUNDING AND TO AVOID I r - - GENSET P ONAL NUISANCE TRIPS. PROVIDE METAL COVERS TO FOR EASY IDENTIFICATION GFI OF OF GFCI RECEPTACLES. WE S y Zi, ANNUNCIATOR I GFI GFI +12'AFF 2. COORDINATE GARAGE DOOR MOTORS WITH OWNERS. PROVIDE MANUAL I I EM-17® I I GARAGE ji 116 EM-30 M TO 122 OPERATION IN CASE OF POWER OUTAGE. MECH-28,30 I A_13 ® GARAGE � UH J 1 UP DOOR �- -� )FFICE EM-2 POLE 125--1 I o N� M-27 �`-_!i 0 I TOIL 0 z �A� O MECH-16 EM-22 UH o GARAGE A-14 PARTIAL YYATPO II�1�11=, UH AC J 1 PARTIAL MECH-16 YY 1 J GFI GFI I HEATER PARTIAL Q L0 EF IGNITION MECHANICAL SCHEDULE I I EM-21,23 la ECH-32 4 M TO J HEATER i O IGNITION TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS GFI J THERMAL 3 r - - - - _4 J - - - - B-1,2 BOILER 50OW 120 1 GFI I EM-28 M TO (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P U) > O PROTECTION I I L) I I GARAGE U CH-1 CHILLER 28.8 FICA 208 1 (4#12CU,1#12CUG)1"C 60/2 40A2P I I - - I - - - - - - - - - TRUCK DOOR D�CON I I GARAGE POWER O J GFI I A-15 ui _ CU-1 CONDENSING UNIT 26.4 MCA 208 1 (3#8CU,1#12CUG)1"C 60/2 40A2P I 119 i I Z Q APPARATUS THERMAL I I o o � EF-1 EXHAUSTFAN 21W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P rl_--_-n ui U) PROTECTION I "-77 �� I I 124 THERMAL I W EF-2 EXHAUSTFAN 62W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P I AIR PROTECTION COMPRESSOR i EM-24 THERMAL FC-1,2,5 FAN COIL 1/6HP 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P M 8 6 PARTIAL PROTECTION J PARTIAL THERMAL O W�vv_ '` HEATER FC-3,4 FAN COIL (2)1/6HP 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20AlP EM-18,20 A *+, EM-26 IGNITION PROTECTION ® 1O THERMAL J GFI J GARAGE GF-1,2,3 GLYCOL FEEDER 50W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P GFI A-31 A EM-26 M TO PROTECTION TRUCK GARAGE THERMAL POWER HRV-1 HEAT RECOVERY VENTILATOR 610W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P DOOR PROTECTION AEC PROJECT #: 12017 I P-1,2,3 PUMP 92W 208 1 (3#12CU,1#12CUG)1"C 30/2 20A2P N GFI I THERMAL DATE: ISSUE: P-4 PUMP 45W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P ORK/TOQLS I 12-19-12 DRYER VENT REV. �g PROTECTION THERMAL I I , 12-19-12 RFC #067 A P-5 PUMP 85W 120 1 (2#12CU,1#12CUG)1/2"C OVERLOAD 20A1P G I 117 01-02-13 REVISION #11 11 PROTECTION I ACTUATED CAI I I ' 02-06-13 ASI # 015 A P-6 PUMP 370W 208 1 (2#12CU,1#12CUG)1/2"C 30/2 20A2P LOUVER 03-07-13 ASI # 016 1 ' EM-12 03-25-13 ASI #016 REVISION 1 MECH-16 EM-16 P-7 PUMP 1/2HP 208 1 (2#12CU,1#12CUG)1/2"C 30/2 20A2P O EG_1 EM GARAGE Drawn By: Checked By: _ A-17 CTL AEC ACTUATED PANEL GFI GFI O - O GFI 3 LOUVER ] GFI \ M M ELECTRIC UNIT HEATER SCHEDULE OR EQUIVALENT ` � V � V TO TO _ LOWER ELECTRICAL DATA DIMENSIONS OPER. M GAS WP LEVEL UNIT MANUFACTURER& CAPACITY EAT LAT ENGINE TAG MODEL NO. SERVICE LOCATION (BTUH) (°F) (°F) KW AMPS V/PH/Hz L(IN) H(IN) W(IN) LB REMARKS EXHAUST RADIANT GFI ( S) FAN HEATER UH-1 RAYWALL SEE PLANS WALL MOUNTED 2560 45.0 95.0 075 3.1 208/1/60 17 8 3.5 INTERLOCK W/T-STAT,CONSULT LOCATION W/ARCHITECT MAIN CT (PLYMO-VENT) I 1 OWER .HF4475T2RP DISCONNECT NORTH D UH-2 RAYWALL SEE PLANS WALL MOUNTED 6826 45.0 95.0 2.00 8.3 208/1/60 17 8 3.5 INTERLOCK W/T-STAT,CONSULT LOCATION W/ARCHITECT PLAN HF4420T2RP LOWER LEVEL. 1 lr UH-3 RAYWALL SEE PLANS WALL MOUNTED 3413 45.0 95.0 1.00 4.2 208/1/60 17 8 3.5 INTERLOCK W/T-STAT,CONSULT LOCATION W/ARCHITECT �� _ ��HF4410T2RP SCALE 1/4 = 1 -0 POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0' 2 ,00 4 of 10 ®COPYRIGHT 2005 ARCHITECTURAL ENGINEERING CONSULTANTS,INC. 0 N B C ate-+ O U)LOCATE CONNECTIONS AT PLATFORM ABOVE I I MECHANICAL EQUIPMENT. COORDINATE I NORTH STAIR I � - � CONNECTION LOCATIONS WITH TOWN OF VAIL. I I O U 0o EM-32,34 EM-36 / 21 C= MECH-31,33 I 0 45 O I r®, � O Q O J HEAT U N0 m E 30A2P TRACE 20A1P ' �� O N X O GENERAL NOTES: IT RACK IT ANTENNA i m U � � (D L - CIRCUIT MECH-19 ME H-11,13 CO"NS IRS I 'L O _ 1. ALL GFCI AND WATERPROOF-GFCI RECEPTACLES SHALL BE PROVIDED I � —j U .> WITH METALLIC JUNCTION BOXES AND COVERS. PROVIDE METALLIC M TO EF UH s J Q N N JUNCTION BOXES TO ENSURE PROPER GROUNDING AND TO AVOID 1 MECH-27,29 e J MECH-15,17 I o6 � (> LOCATE CONNECTIONS IN MECHANICAL ROOM. COORDINATE CONNECTION O MECHi 1 - _ 2 06 0o a) NUISANCE TRIPS. PROVIDE METAL COVERS TO FOR EASY IDENTIFICATION LOCATIONS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. HEAT _ .� M Q CO 00 OF GFCI RECEPTACLES. TRACE J 211 J I � L Lu >'ti EM-19 MDP MECH 3H w J 2 O PANEL I � U B B GF GF GF CH GFI OWP I LLI Z e e e - - - - - - - - - GFI GFI - - - - - ate-+ C6 C) C: U O ® i= VTO VTO r__6�TO� M RANGE rWAC � 00 L TO AC -t O � 0. EHU A-1 0 SHEET DETAIL NOTES: C GFI GFI AC DORMA-21 (ll EM-1 MECH-2 MECH-22 MECH-1,3 T AC GFI DORM A-23 (, � Q N NN I STUDIO GFI DORM A-11 = i- 00 1O LOCATE CONNECTION FOR HEAT RACE AT ROOF. COORDINATE TO DORM A-17 Q X LOCATION IN FIELD PRIOR TO ROUGH-IN. P P P P P P P 2 e e e e e e e I E DISP 229 1 AC DORM A-15 o N �I m O2 PROVIDE HOLIDAY LIGHTING RECEPTACLES UNDER ROOF EAVE, ����y�Ip��r�� �� r�� ����yp�r�� ���nyp�� o COORDINATE LOCATION WITH OWNERS PRIOR TO ROUGH-IN. �'�� �'' -hCK1 M TO M TO � � DW GFI I KITCHEN EHU A- DORM A-13 EM-3,5 MECH-4,6 MECH-8,10 EM-7 MECH-12 MECH-14,16 MECH-18,20 AC EHU A-3 D� - GFI Will ] - Ac IVINC� �I DISP AC GFI EHU A-19 GFI DORM A-1 ?25 MW RANGE EHU A-9 I L \ AC EHU DORM A-3 12 GFI EHU A-15 A-21,23 FRIDGE EHU A-15 EHU A EHU A-5 DORM A-7 DORM A-9 DORM A-19 • • ' Cj 2 Z 4`r AC PANEL EM-10 WP - GFI - - - JE - 1..7 GFl- `S��ONA'l.EHU A-14 FRIDGE F I GE +12'AFF GF - W� gSF{ER - GFI VVF-b r bl AIR DRYER FC I HALL 226 EHU e 3ET 214 h F7 _ • LOCATE CONNECTIONS IN ATTIC SPACE D A-16,18 M 1 P'btE I DORM A-25 ABOVE HALL AND BATHROOMS. COORDINATE TO CV CONNECTION LOCATIONS WITH MECHANICAL - - DORM B-11 CONTRACTOR PRIOR TO ROUGH-IN. 213 EM-9 EIA PARTIAL GFI ; AC ANGE GFI DORM B-13 GFI DORM A PARTIAL DORM B-7 AC EF O Iff EHU PANEL WASHER = DN AC B-10,12 GFI GFI M TO DORM B T EF em O GFI B DROO DRYER PANEL EHU B-9 DISP II II EHU B-19 �1 TO ORM A-34 � � 222 EHU EHU B-14 FRIDGE II III DORM B-15 � EH B-11 WASHER 7- 8-16 18 EHU B-13 U C PARTIAL DRYER �� AC AG � - r 4_ � GFI GFt AC - — - — EHU B = I GFI U) PANEL I DORM A-32 O +8'AFF > e , I ui DORM B-9 � v 111 O C Lu _ I � Z Q > Lu U) EHU B-1 213R / LIVING J BEDS - - - -� EHU B-3 GF� 219 DORM B-3 DORM B-5 M Q TO EHU B-25 237 EF DORM B-1 1 0 GFI EHU B-7 3 I NI-C.LV�F� AEC PROJECT #: 12017 M TO 1 M TO 38 I DATE: ISSUE: 1 _ 1 PARTIAL EHU B-23 12-19-12 DRYER VENT REV. Zg 12-19-12 RFC #067 ❑ L GARAGE A-29 01-02-13 REVISION #11 11 EDROOM 02-06-13 ASI # 0150 03-07-13 ASI # 016 1 BEDROOM I 239 WP GFI 03-25-13 ASI # 016 REVISION 1 242 I MECH-35,37 Drawn By: Checked By: MECH-39,41 ' I CTL AEC 1 HEAT J J EAT O TRACE kCE _1 _ _ UPPER M LEVEL cU ED 1 MECH-5,7,9 POWER NORTH UPPER LEVEL. PLAN SCALE 1/4" = 1'-0" A POWER & SYSTEMS PLAN- SCALE: 1/4" = 1'0" 2 ,01 5 of 10 ®COPYRIGHT 2005 ARCHITECTURAL ENGINEERING CONSULTANTS,INC.