Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B12-0318 B12-0319 Insulation Specs.pdf
y,a InsulVail, LLC Post Office Box 2888 Vail, Colorado 81658 970-524-3000 Fax 970-524-3001 Mr. JP Sunderland Sunder Inc. PO Box 1393 Edwards, Co. 81632 VIA Email iRsunder ,vail.net July 19,2012 PROJECT: Zuckerman Duplex SPECIFICATIONS: R-49 Blow-In-Blanket System Fiberglass Insulation (BIBS)to the exterior ceilings R-23 BIBS fiberglass insulation to the exterior walls R-23 BIBS fiberglass insulation to the garage exterior walls R-23 BIBS fiberglass insulation to the garage common wall (Double net) R-15 BIBS fiberglass insulation to the 2x4 furred concrete exterior walls 6 mil poly air/vapor barrier to exterior walls, garage exterior and common wall MemBrain Smart Vapor Barrier to the exterior ceilings and furred concrete exterior walls R-38 unfaced fiberglass batts to the garage ceilings R-19 unfaced fiberglass batts to the mid floors R-38 unfaced fiberglass batts to the crawl ceiling(With strapping) R-11 fiberglass drape to the crawl walls (Mechanically attached) 6 mil reinforced poly air/vapor barrier to crawl floor R-21 unfaced fiberglass Batts to the rim joists R-11 sound batts to 2x4 interior walls R-19 sound batts to 2x6 interior walls Foam all windows, doors and penetrations O!t RECEIVED Date: 04/15/2013 TO WM OF VA!L By: D. RHOADE S Pnrra i ell' i Certa"InTeed C11 ©PTIMA° Fiber Glass Blowing Insulation Builders Statement for use in Blow-In-Blanket' System Homeowner Name/Jobsits Name Home Address Installer/COntracler(sign) Company Name Date • �u crrr sty 11V jLVIA< L.L G Builder(sign) Company Name Date Inspected By(sign if required) Date SIDEWALLS,CATHEDRAL CEILINGS AND OTHER CLOSED CAVITIES THAT ARE COMPRESSION FILLED. NO.OF BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R-VALUE 1,000 SO.FT. SO.FT.PER BAG POUNDS PER SO.FT. THICKNESS To obtain a Bags per Contents of bag Weight per sq.ft.of Should not be Thermal Resistance 1,000 sq.ft. should not cover installed insulation should less than: (R)of: of net area: more than:(sq.ft.) not be less than:(lbs.) (in.) 15 18.9 53 0.525 31h 23 29.4 34 0.825 51h 30 38.5 26 1.068 7'/4 39 50.0 20 1,388 9'/. 47 58.0 17 1.668 11'A 56 71.4 14 1.968 131A FLOORED ATTICS—CLOSED CAVITY€STHAT ARE NOT COMPRESSION FILLED. NO.OF BAGS PER MAXIMUM MINIMUM WEIGHT MINIMUM R-VALUE 1,000 SO.FT, SO.FT.PER BAG POUNDS PER SO.FT. THICKNESS To obtain a Bags per Contents of bag Weight per sq.fl.of Should not be Thermal Resistance 1,000 sq.It. should nol cover installed insulation should less than: (R}of: of net area: more than:(sq,ft.) not be less than:(Ibs.) (in.) 12 10.4 0-292 96 31h 13 12,5 0.350 80 31h 14 14.5 0.408 69 3'/2 14 15.7 0.467 60 31/2 19 16.4 1458 61 51h 21 19.6 0.550 51 5'S 22 22.7 0.642 44 515 22 26.3 0333 38 51/2 26 21.7 0.604 46 7%4 27 253 0.725 39 71/4 29 30,3 0.846 33 7l4 30 34.5 0.967 29 71/4 33 27.8 0.771 36 91/4 35 33.3 0.925 30 91/4 36 38.5 1.079 26 91A 38 43.5 1.233 23 91/4 R-VALUE THICKNESS AREA(SO.FT.) OPTIMA(✓} BAGS USED BATTSIROLLS(✓) CEILINGS WALLS Z F 000 sp FLOORS THERMAL PERFORMANCE R-Values are determined in accordance with ASTM C 687.Complies with ASTM C 764 as Type 1 insulation."R"means resistance to heat flow.The higher the H-Value,the greater the insulating power To get the marked R-Value,it is essential that the insulation is installed properly following the recommendations of CertainTeed Corporation.OPTIMATI loose Fill Insulation is manufactured for closed cavity application installed behind OPTIMA Fabric or equivalent.It should not be used for open blow applications.Coverage is based on a nominal 28 lb.bag.In accordance with the chart above,you must install the minimum number of bags per 1,000 sq.ft.of net area for each R-Value listed.The maximum net coverage must not exceed that specified for each R-Valuc.The installed insulation must be at or above the specified minimum thickness for each H-Value.Failure to install the required minimum wei0t per sq,It.of insulation at or above the minimum thickness will result in reduced R-Value.Thts product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER:RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING,DO NOT INSULATE ON TOP OR WITHIN 3"OF SUCH DEVICES.DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERAMLLY PROTECTED BALLASTS. Blow-in-Blankets System is a registered trademark of Ark-Seal Inc.International,Denver CO 80223.OPTIMA®is a trademark of CertainTeed Corporation. 30-24-218 Builders Statement. A Saint-Gobain Company. 02006 CertainTeed Corporation 9106