Loading...
HomeMy WebLinkAboutB13-0039 REV1 Application and Cut Sheets Department of Community Development 75 South Frontage Road Vail,CO 81657 ta � ' Tel: 970.479.2128 www.vailgov-com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two.hour minimum budding review fee of$110 will be charged upon reissuance of the permit. - Application/Permit#(s)information applies to: Attention: Revisions Response to Correction Letter 13 on, ,39 E)_attached copy of correction letter --� , /� (Deferred Submittal J 13 -00 ZO (Other Project Street Address: %L't FoResT RoA►D (Number) (Street) (Suite#) Building/Complex Name: Description of Transmittal/List of Changes, Items Atfached: �ep�r�c� � aD►t�RS Applicant Information (architect,contractor,ownedowner's rep) Contact Nam ES S PAR-w\ L Q Address: 0•,^, C3D7� City W 0 L nnW State: CID Zip: $66 55 Contact Name: .,,J,*Af eS ��R/� /L (use additional sheet if necessary) Contact Phone: Building Permits: T f)L.� Revised ADDITIONAL Valuations (Labor&Materials) Contact E-Mail: v 1(DO NOT include original valuation) I hereby acknowledge that I have read this application,filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: $ �}.5 00. 00 comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according Electrical: $ to the town's zoning and subdivision codes, design review ap- proved,International Building and Residential Codes and other Mechanical: $ .5.5) OQ o -00 ordinance of the Town ppli le thereto. Total: $ _ weer wner's a sentative Signature(Required) ------------------------------------------------------------ Date Received: Pp For Office Use Only: Fee Paid: APR 17 2013 Received From: Cash Check# CC: Visa/MC Last 4 CC# exp.date: Authorization# 'OWN OF VAIL HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS C k: COMMERCIAL BOILER _ ci OPERATING CONTROL FEATURING Lochimar A BUILT-IN CASCADING SEQUENCER • 5 MODELS: 399,000 - 800,000 BTU/HR LO NOK Certi FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx DIRECTVENTFLEXIBILITYTO 100 FEET UP T094.6% THERMAL EFFICIENCY 0 1 J ivi Loch in var.com COMMERCIAL BOILER g t. 00 0 THE SMARTEST 1010ETOR C!ONDE3N C SING OILER PERFORMANCE. '. The KNIGHT'XL, engineered with Lochinvar's e�CClusrve S Y MTM co _ an array of other innovative features, plac#s it far ahead of ati'commercial heating boiler in its class.It promises and delivers ultimate ease of installation and maintenance. With up to 94.6%thermal efficiency, low-NOx emissions and a fully modulating burner, it is the best "green choice" for today's environmentally focused market. Five modulating/condensing stainless steel KNIGHT XL boilers are available with 399,000-800,000 Btu/hr inputs and remarkably small-space-saving footprints.All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC,CPVC orAL29-4C vent materials.This range of choices is ideal for light duty applications such as small hotels, schools and office buildings. For higher-demand applications,up to eight KNIGHTXL units can be installed utilizing the built-in cascading sequencer to deliver up to 6.4 million Btu/hr heating capacity. THE KNIGHT XL BOILER reflects Lochinvar's constant commitment to providing all the options you need to serve every application. KNIGHTXLs installed and commissioned by i Black&McDonald �Y ADVANCED NEGATIVE REGULATION TECHNOLOGY KNIGHT XL safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg)technology automatically adjusts fan speed that ensures the correct volume .•rl f ..,..i.. ...::.TM FSMAFZT ) XEEINED DESIGN PUTS MORE CONTROL — NEST N4 Bp c_1, /AIKn2!IAAT!r)AI ATV f'rp-ri c:- " ^tn .. YO Fl�� a RESET Advanced features include: • MULTI-COLOR GRAPHIC LCD DISPLAY • NAVIGATION DIAL SCROLL • USB PORT • • ABILITYTO CONTROL UP TO THREE DIFFERENT SETPOI NT TEMPERATURES • MODBUS CAPABILITY(OPTIONAL) Q?\ � S1Lt_,q • DHW MODULATION LIMITING Select • DHW NIGHT SETBACK* • 0-10 V BOILER RATE OUTPUT Ay, Seiect • 0-10VSIGNALTO CONTROLVARIABLE SPEED BOILER PUMP* • 0-10V SYSTEM PUMP SIGNAL INPUT* • HEAT DEMAND FROM 0-10V INPUT -- n n REM., • INSTALLER TO PROGRAM NAME AND NUMBER INTO THE BOILER • FREEZE PROTECTION PARAMETERS INSTALLER ADJUSTABLE _ • T SEPARATELY ADJUSTABLE SH�DHW SWITCHING TIMES* • INSTALLER ACCESS TO BMS AND RAMP DELAY SETTINGS BLUE SCREEN YELLOW SCREEN RED SCREEN *ExcLusIVE TO LocHINVAR SMART SYSTEM Normal system Maintenance due-shows Lockout mode. operation. the installer's name and NEW SELECTABLE CASCADE OPTIONS number on the display. When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for"Lead-Lag" cascade or"Efficiency Optimized" cascade operation, LEAD-LAG CASCADE - TIP"017ED 5C C), (0J - --- 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 The"lead unit"boiler modulates with demand to capacity.As demand This feature optimizes the modulation capabilities of the Boiler Plant while increases,additional boilers fire and modulate to capacity.This continues,with evenly distributing run time across all cascaded boilers.Every 24 hours the additional boilers firing and modulating to capacity until all units are operating. SMART SYSTEM automatically shifts the 1st boiler on role to the next in the Every 24 hours,the SMART SYSTEM automatically shifts the lead boiler role to sequence,distributing run time equally. the next in the sequence,distributing lead-lag runtimes equally. SMART SYSTEM Cascade option allows 2-8 boilers to be sequenced. EXIBLE VENTING OPTIONS Direct Vent Sidewall Direct Vent Vertical Room Air Sidewall Room Air Vertical Vertical w/Sidewall Air Direct Vent Vertical* Direct Vent Sidewall* r i � - � �-• - .ice � bM` �� ".y;'°�s,y '; u ~y Y - _ *Optional Concentric Vent Kit Sold Separately(for 399-600 Models) KNIGHT°XL BOILER DIMENSIONS AND SPECIFICATIONS LOW VOLTAGE ELECTRICAL CONNECTIONS NIGH VOLTAGE —H ELECTRICAL GAS CONNECTIONS \ I 1 O O 000 0 AIR INLET Model KB N 701 M13 J HEAT p y ' EXCHANGER O' INLET OUTLET DRAIN 3/1'NPT N/ / p 39-1 FLUE 3"4' A d •� 7^ Oi ry CONDENSATE s FLUE I DRAIN Knight&Boiler, Tom•. Natural Gas, taau' 700,000 Btu/hr input, 9' M13 firing controls a E ADJUSTABLE E BACK �A FRONT LEFT SIDE TB' KNIGHTXL HEATING BOILER rB' DIMENSIONS AND SPECIFICATIONS Model Input Net Output I=B=R A B C 1 E F G H I I K Gas Water Air Vent Shipping Number KBN400 80 399 93.3% 372 324 42-1/2" 15-1/2' 27-3/4" 3-3/4" 20-3/4" 21" 14' 34" 34" 2" 18-3/4"Conn. 1" 1-1/2" 4" 4" 280 KBN501 100 500 93.3% 467 406 42-1/2" 15-1/2' 31-11r 3-3/4' 25-11r 21' 14" 32-1/2" 36" r 18' 1" 1-1/2' 4' 4' 310 KBN601 120 600 94.6% 567 493 42-1/r 15-1R' 36.1/4' 3-3/4' 25' 21' 14' 36" 32-3/4" 5-1/2' 19-1/2' 1" 2' 4' 4' 340 KBN701 140 700 94.3% 660 574 42-1/2" 15-1R' 40-1/4' 3-3/4" 29' 23' 17' 36' 32-3/4" 3-1/4" 23-1/2' 1" 2' 4' 6" 370 KBN801 160 800 94.0% 752 654 42-1/2' 15-11r 45-1/4' 3-3/4' 33-1/4' 23" 17' 36" 32-3/4' 3-1/4' 27-3/4" 1' 2' 4" 6" 405 Notes:Indoor installation only.All information subject to change.Change"N"to"L"for LPgas models. STANDARD FEATURES SMART SYSTEM FEATURES >High Voltage Terminal Strip >Up to 94.6%Thermal Efficiency >SMART SYSTEM Digital Operating Control >120 VAC/60 Hertz/1 Phase Power Supply >Modulating Burner with 5:1 Turndown >Multi-Colored Graphic LCD Display w/Navigation Dial >Three sets of Pump Contacts with Pump Relays >Direct-Spark Ignition >Three Reset Temperature Inputs >Low Voltage Terminal Strip >Low NOx Operation with curves for three set point temperature inputs >24 VAC Device Relay >Sealed Combustion >Built in Cascading Sequencer for up to 8 Boilers >Proving Switch Contacts >Lead Lag >Flow Switch Contacts >Low Gas Pressure Operation >Efficiency Optimization >Alarm on Any Failure Contacts >ASME Stainless Steel Heat Exchanger >Outdoor Reset Control with Outdoor Air Sensor >Runtime Contacts >ASME Certified,"H"Stamped >Programmable System Efficiency Optimizers >DHW Thermostat Contacts Gasketless Heat Exchanger >Night Setback >3 Space Heat Thermostat Contacts >160 psi Working Pressure >DHW Night Setback >System Sensor Contacts >50 psi ASME Relief Valve >Anti-Cycling >DHW Tank Sensor Contacts >Highly efficient,condensing design >Outdoor Air Reset Curve >Outdoor Air Sensor Contacts >Ramp Delay >Cascade Contacts >Vertical&Horizontal Direct-Vent >Boost Temperature&Time >0-10 VDC BMS External Control Contact >Category IV venting up to 100 feet >Three Pump Control >0-30VDC Boiler Rate Output Contacts >PVC,CPVC or AL29-4C Venting up to 100 Feet >System Pump With Parameter for Continuous Operation >0-10VDC Variable Speed System Pump Signal Input >Factory Supplied Sidewall Vent Termination >Boiler Pump With Variable Speed Pump Control >0-10VDC Signal to Control Variable Speed Boiler Pump >Smart System Control >Domestic Hot Water Pump >Modbus Contacts >Other Features >Domestic Hot Water Prioritization >Time Clock >On/Off Switch >DHW tank piped with priority in the boiler loop >Data Logging >Adjustable High Limit w/Manual Reset >DHW slcont ollezone he Smart System m h >Hours Running,Space Heating pumps Y Y g >Automatic Reset High Limit . >DHW Modulation Limiting >Hours Running,Domestic Hot Water >Flow Switch >Separately Adjustable SH/DHW Switching Times* >Ignition Attempts >Building Management Integration >Last 10 Lockouts >Flue Temperature Sensor 8 g System Int tion > >Low Air Pressure Switch >MODBUS Communication(Optional) Other Features >0-10VDC Input to Control Modulation or Set Point >Low Water Flow Safety Control&Indication >Temperature&Pressure Gauge >0-10VDC Input Signal from Variable Speed >Password Security >Adjustable Leveling Legs System Pump* >Inlet&Outlet Temperature Readout >Condensate Trap >0-10VDC Modulation Rate Output >Customizable Freeze Protection Parameters >Zero Clearances to Combustible Material >0-10VDC Input to Enable/Disable call for heat >Custom Maintenance Reminderwith Contractor Info >10 Year Limited Warranty(See Warranty) >Access to BMS Settings through Display *Exclusive feature,available only from Lochinvor FIRING CODES OPTIONAL EQUIPMENT )M9 Standard Construction >Alarm Bell >Low Water Cutoffw/Manual Reset&Test >Condensate Neutralization Kit) >SMART SYSTEM PC Software >M7 California Code >Concentric Vent Kit(KB400-KB6oi) >Stainless Steel Vent Kits(KB701-KB801) >M13 CSD1/FM/GE Gap(KB501-KB801) >High&Low Gas Pressure Switches w/Manual >Stack Frame Reset(05o1-08o1) of e my � chwair � p un' R * ® M E M B E R Patent Pending �U 'L0 Efficiency Water Heaters,Boilers and Pool Heaters • • . / / 1 • 1 • / 1 • • • : • : • • • • • • In • gas 1 1 . . 1• Ill 1 ' •• . STAINLESS STEEL INDIRECT WATER HEATERS Sauire 5ta6f&" see lwaw'at ZUa d "t 12 SQUIRE MODELS TO CHOOSE FROM - 6 STANDARD MODELS FROM 30 TO 119 GALLONS - 6 SOLAR MODELS FROM 65 TO 119 GALLONS " 316L PASSIVATED STAINLESS STEELTANK 1 � _1h b 304L HIGH CAPACITY STAINLESS STEEL COIL ' FULLYWELDED CONSTRUCTION "c ar `� High Efficiency Water Heaters,Boilers and Pool Heaters Sauire sr ear Steee lg4=r Zarm Air - a new Class of Water Heater Introducing Lochinvar's newest member of the family, the Squire Stainless Steel Indirect Water Heater. With 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to ft your application. Squire now features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat exchanger, two-inch thick, high-density insulating foam with a tested R Value of 13.4, and best of all an American made product built in Lebanon, Tennessee. Stainless Steel Tank Manufacturing Laser Cut Precision A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water Heater's tank shell out of 14 gauge 316L stainless steel to a tolerance of.01 inch. Tank Cylinder Roller The computer controlled tank cylinder rolling machine ensures that the 316L stainless steel is transformed into a geometrically perfect cylinder. - � Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise,round LASER Cut reCi5lon coil used in the indirect water heater to transfer the BTU's from the heat source to the potable water stored in the tank. Robotic Welder This state of the art six axis programmable robotic welder uses computer guidance to ` accurately weld all of the stainless steel fittings and coil to the stainless steel tank. ? ; d Hydrostatic Leak Test N After it leaves the robotic welder the tank is hydrostatically pressure tested to ensure quality conformance. Passivation Process l Each tank is subjected to a soaking spray of ' nitric acid.This treatment washes away any iron that was left behind during the welding process and re-establishes the oxide level of the stainless steel to ensure corrosion resistance. Robotic Welder By removing iron from the welded surfaces,the Squire is less susceptible to corrosion brought I on by aggressive water. y Jacket and Foam The dent resistant polypropylene jacket and ABS ++h . caps are attached to the tank assembly,and then high density foam is added using a high pressure . dispensing system to provide insulation that will keep the heat where it belongs, in the water.The ` - result is an evenly foam insulated and jacketed - tank with an R-value of 13.4 and stand-by losses as low as.5°F per hour,depending on model. ' Passivated for Protection R-13.4 Foam Insulated Outstanding Features Six Standard Models from 30 to 119 Gallons 316L Passivated Stainless Steel Tank The highest quality indirect water heater in the market also has 316L Stainless Steel material is used for the tank interior for one of the widest ranges of gallon capacities. With 6 models superior durability and long life. The rust prohibitive characteristics covering gallon capacities from 30 to 119 gallons the Squire is of this material make it the perfect material to resist the corrosive one of the broadest lines available. tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior Six Solar Models from 65 to 119 Gallons corrosion resistance of stainless steel. With three dual coil models for solar heating in conjunction with a boiler and three models with a solar coil and an electric 304L High Capacity Stainless Steel Coil element the Squire line of water heaters has a model to ft any The Squire's 304L Stainless Steel heating coil efficiently transfers high residential or light duty commercial solar application. volumes of BTU's from the heat source to the domestic water stored in 100%Stainless Steel Construction the tank The high first hour delivery rivals the best in the industry. Squire Water Heaters are constructed with Stainless Steel Built in the U.S.A.at Lochinvar's World Headquarters materials that are highly resistant to corrosion that results from A 100%stainless steel indirect water heater built in the USA, poor water quality. the Squire is completely assembled in Lebanon, Tennessee. f How it Works Inside Look Dent resistant polypropelene jacket* Te Stainless Steel SIT Indirect &pres The Squire uses the power and efficiency of the relief 1"' building's heating boiler or solar array to also generate domestic hot water for showers, dishwashing, clothes S ::. Boiler ensor washing or any potable hot water demand. The water inlet well, efficiency of the heating boiler could be as much as 20% higher than a direct-fired tank-type water heater. So,why 304E not use that efficiency to "indirectly" provide hot water for Stainless all potable applications? Steel coil I By using the Squire to indirectly heat the domestic water,you Boiler water eliminate the additional gas line,electrical connections and vent ducts needed with direct-fired tank-type water heaters. outlet High densi - foam insulat fold water / a inletU {SET models feature m l Heating Boiler with our quIre Indirec' r the perfect combination for our applic' n. Fully Welded Construction T&P Relief Valve Lochinvar utilizes state of the art highly accurate robotic Supplied with the unit in the carton. (shipped loose) welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing High Density CFC/HCFC Free Polyurethane Foam methods. Gaskets and seals are the weak point of any water Two inches of R-13.4 High Density Polyurethane foam yields storing appliance, therefore Lochinvar's advanced design the lowest standby losses in the industry. eliminates this potential failure point. Attractive Rust Resistant jacket Factory Supplied Tank Sensor (SIT and SDT only) Resistant to scratches and dents, the Squire will maintain its A tank sensor with built in temperature limit is standard classic high quality appearance for years. equipment on all sizes. This sensor accurately monitors the water temperature and sends a call for heat when the tank Limited Lifetime Warranty* temperature drops below the desired setpoint. This sensor Lochinvar believes that the Squire is the best built Indirect is 100%compatible and can be directly connected with Water Heater on the market, we have a Limited Lifetime Lochinvar's line of KNIGHT Heating Boilers. warranty to prove it. *SIT models only Solar Indirect with SOT Dual Coil Solar Indirect with SET Electric Back-up Squire Indirect Water Heaters with a dual coil design Squire Indirect Water Heaters with a single coil and have a coil in the lower portion of the tank to transfer an electric element are designed to collect heat from heat from a solar array to the water that is stored in a solar array and transfer the collected heat into the tank. the stored water by way of the indirect coil which is An additional coil in the upper portion of the tank located in the lower portion of the tank. will transfer heat from a back-up boiler into the An electric element,which is controlled by a factory water.This will ensure that the tank has ample hot supplied thermostat, is positioned in the top half of water even at times when the solar array cannot the tank to ensure ample hot water even at times generate enough heat to suitably heat the tank. when the solar array is not capable of collecting the heat required by the DHW demand. T - ® 0 Solar Stainless Steel Indirect Dimensions and Specifications HOT WATER Q OUTLET FROM HOT HOT WATER OUTLET BOILER RELIEF VALVE SENSOR ;a (>Pp 1 WELL RELIEF VALVE TO (.Pp.boeal BOILER / 22 5" 45° \ �I-22.8-. A FROM FROM PANEL D PANEL D P E ` SOLAR SOLAR SENSOR SDT Models F WELLOR SET Models WELL G G TO TO PANEL PANEL H f H I I COLD WATER COLD WATER INLET INLET SDT Models Dimensions and Specifications Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt. (tbs.) SDT065 60" 24" 52-1/4" 47-1/4" 33-3/4" 28" 9-1/4" 3-1/4" 1-1/2" in 158 SDT080 69-1/4" 24" 61-3/4" 53-3/4" 40-1/4" 28" 9-114" 3-1/4" 1-1/2" 1" 188 SDT119 68" 28" 60-1/4" 54-1/2" 37-1/2" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 224 Boiler Heat Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) Volume(Gals.)Volume(Gals.) (OF/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 65.5 2.1 1.7 0.5 174.6 204.7 128,000 14.0 3.4 SDT080 78.4 2.1 1.7 0.5 174.6 207.1 128,000 14.0 3.4 SDT119 109.8 3.2 2.6 0.4 250.2 300.5 181,000 14.0 4.9 Performance data based on incoming cold water at 50'F and a Delta T of 77°F. Delivery ratings for baler coil only.Includes tank sensor for use W IGv7GHT Heafing Boiler. SET Models Dimensions and Specifications Domestic Coil Model Water Connection Shipping Number A B D F H I Conn. Size wt.(tbs.) SET065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" in 149 SE1080 69-1/2" 24" 61-3/4" 28" 9-114" 11/4" 1-1/2" 1" 179 SET119 68-1/4" 28 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1" 215 Electric Electric Heat Source Standby Continuous Ist Hour ° Delivery Deliver All models standard with a 5 year _ Limited Warranty Against Tank Failure. Numb (Gallons) - (Gallons) CF/Hr) (GPH) (Gallon All parts are warranted for one year* SET065 67.0 1.9 0.5 23.9 54.0 *SET&SDT models only SET080 80.9 2.1 0.5 23.9 56.4 SEH 19 112.4 3.2 0.5 23.9 74.2 All SET models:4500w 24N 1 phase. r s �S � @ us �� Lochinvar° Iv "SET models only Nigh Efficiency Water Neaters,Boilers and Pool Heaters F21 Lochinvar Corporation • 300 Maddox Simpson Pkwy• Lebanon,TN 37090 • 615-889-8900/Fax: 615-547-1000 www.Lochinvar.com SIT-02 (Replaces SIT-01 3/10) FG-20M-6/1 I-Printed in U.S Stainless Steel Indirect SIT Models Dimensions and Specifications -- B i _ HOT WATER OUTLET RELIEF VALVE (shipped Bose) A BOILER -22.51 IN •\ 45° D SENSOR WELL BOILER OUT H1 I COLD WATER INLET Domestic Model pp Number SIT030 39-1/2" 20" 32-1/4" 21-3/4" 8-1/4" 3" in in 79 SIT040 55-1/2" 20" 48-1/2" 25-1/4" 8-114" 3" In in 105 SIT050 47" 24" 39-314" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-114" 28" 9-1/4" 3-1/4" 1-1/2" in 147 SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" IN 177 SIT]19' 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" l" 213 Standby Heat Source Model Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (OF/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27.0 1.1 1.5 24 160 183 99,000 14.0 3.9 SIT040 40.0 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 51.6 1.7 0.9 47 209 255 133,000 14.0 5.3 SIT065 67.0 1.9 0.7 65 263 327 154,000 14.0 5.7 SIT080 81.5 2.1 0.6 74 266 347 160,000 14.0 5.7 SIT119 113.4 3.2 0.5 109 349 459 216,000 14.0 6.5 Performance data is based on I=B=R test results.All ratings are based on 180°F boiler water temperature with incoming cold water at 50°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT Heating Boiler. Optional thermostat available for use with other boiler models. All models standard with a Lifetime Limited Warranty Against Tank Failure. All parts are warranted for one year � Five year limited tank warranty on all AN1.2.1 CERTIFIED- I.B\ �® models when installed in a commercial ^R C US application.. ,sl.)m axis *SIT models only CONDENSING RESIDENTIAL GAS BOILERS HEATING BOILER my r M ART1 MRMPMKI.,M CONTROL WITH ALL NEW, ADVANCED USER FEATURES 5 FLOOR-STANDING AND 5 WALL-MOUNT L01 NO :mx MODELS FROM 50,000 TO 285,000 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx UP T096% DIRECTVENT FLEXIBILITY TO 100 FEET AFUE EFFICIENCY UP TO 98% EFFICIENCY ;r ENERGY STAR knightheatingboiler.com HEATING BOILERS -- - UP TO 96% DOE AFUE EFFICIENCY TH E P - YO U CAN P 1 Now EVEN B r7--rr7 f KNIGHT is recognized for it's reliable,proven performance and high quality standards.Its award winning design assures contractors and home owners peace of mind and long term savings in operating costs. Now, Lochinvar has raised the KNIGHT standard to even greater heights.The dramatically enhanced SMART SYSTEM"'control with color display gives installers and maintenance personnel a greater level of control than ever before. It's easier to access all the information they need to setup, troubleshoot and monitor all boiler functions.Additionally, two new cascading options allow the installer to fine-tune sequencing of multiple boiler installations. More than ever, KNIGHT is the best choice for traditional hydronic space heating, radiant floor heating and domestic hot water applications. VIE-_ WALL MOUNT BOILER 7[:L •1irni WALL-MOUNT MODELS LOW Un. 5 space-saving KNIGHT Wall-Mount Boilers are available from 50,000 to 210,000 Btu/hr. ' All KNIGHT Boilers meet or exceed the most stringent $ requirements,with less HEATING BOILERS than 20 ppm NOx. FLOOR STANDING MODELS The KNIGHT Floor-Standing lineup features ...... 5 small footprint models from 80,000 to 285,000 Btu/hr. The KNIGHT Boiler has earned the KNIGHT XL COMMERCIAL ENERGY STAR,signifying that it has met strict energy- Need more BTU's? KNIGHT XL Commercial Boilers are available efficiency guidelines set by in 5 sizes from 399,000 to 800,000 Btu/hr.See KNIGHT XL the EPA and U.S. Department of Energy. literature for more details. REFINED DESIGN PUTS MORE �L AND INFORMATION ATYOUR fINGEr yEOTryc BpJ�E,R The new SMART SYSTEM"'is the most advanced integrated boiler control on the market today. RESET *•,+� LARGER LCD SCREEN # Displays more information. U SCROLL SoFr KEYS For simple programming. ( SMART NAVIGATION DIAL For fast transitions from screen to screen Sway r and easy adjustment of settings. Select USB PORT USB port permits connection to a laptop computer.SMART SYSTEM PC select software may be used to troubleshoot and program KNIGHT'functions, set date and time,monitor historical data,including faults,trends and energy consumption. AT-A-(.LIAIvLt COLOR-CODING LOCKOUT BLUE SCREEN YELLOW SCREEN NO FLPME IGNITION RED SCREEN SYSTEM: 117-F<118) LIHW TANK: 124'F<13111 Normal system Maintenance due-shows Lockout mode. operation. the installer's name and number on the display. NEW SELECTABLE CASCADE OPTIONS When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for"Lead-Lag" cascade or "Efficiency Optimized" cascade operation. LEAD-LAC CASCADE EFFIC IE[-, ED CASCADE I L-1 L-"H 0 0 0 0 A Z� 0 0 0 0 0 0 0 0 0 *.The"lead unit"boiler modulates with demand to capacity.As demand This feature optimizes the modulation capabilities of the Boiler Plant increases,additional boilers fire and modulate to capacity.This while evenly distributing run time across all cascaded boilers.Every 24 continues,with additional boilers firing and modulating to capacity hours the SMART SYSTEM automatically shifts the 1st boiler on role to until all units are operating.Every 24 hours,the SMART SYSTEM the next in the sequence,distributing run time equally. automatically shifts the lead boiler role to the next in the sequence, distributing lead-lag runtimes equally. SMARTSYSTEM Cascade option allows 2-8 boilers to be sequenced. DIAL IN SYSTEM PERFORMANCE BUILDING INTERNAL CASCADING SEQUENCER NEW! SEPARATELY ADJUSTABLE MANAGEMENT NEW! WITH MULTIPLE SH/DHW MODE SWITCHING TIMES PROGRAMMABLE SYSTEM Allows controls to be tailored to meet system INPUTS & OUTPUTS EFFICIENCY OPTIMIZERS demand.Design system setup for flexibility. Fine-tune installations using Lead-Lag or Efficiency Optimization Cascade features. NEW! INDIRECT WATER HEATER NEW! ZONE PUMP CONTROL OPTIONAL MODBUS CAPABILITY NEW! Allows boiler communication through Modbus All boilers in cascade can be used to meet DHW protocol.Simplifies BMS/boiler interface for CONTROLS UP TO THREE demand as well as satisfy building load. status monitoring. SETPOI NT TEM PERATU RES Allows three different temperature inputs to SYSTEM&BOILER PUMP CONTROLS 0-10V BUILDING MANAGEMENT be controlled.Boiler can be run at the lowest Provides power to system and boiler pumps on a SYSTEM(BMS)CONTROL INPUT temperature demand for optimal efficiency. call for heat.Programmable post purge allows pumps to operate after a call has been satisfied. BMS-driven input for modulation rate or NEW! Option for Continuous System Pump Operation. temperature control. OUTDOOR RESET FOR EACH TEMP LOOP NEW! PUMP RELAY WITH NEW! 0-10V CASCADE$ETPOINT The boiler setpoint temperature responds to FREEZE PROTECTION AND MODULATION CONTROL changes in outdoor air temperature.Outdoor BMS-driven input for modulation rate or temperature monitor guides the reset schedule Parameters adjustable by installer for flexibility temperature control of cascade. to meet the load. in low-temperature applications. NIGHT;SETBACK NEW! INSTALLER ACCESS TO NEW! 0-10V HEAT DEMAND INPUT BMS AND RAMP DELAY SETTINGS Enables thermostat the a 0 lOV signal to initiate Prograrrf a heating loop temperature setback for a call for heat.Gives the BMS options on how to any time of the day,each day of the week. Set up or changethese parameters through the enable boiler or cascade. control itself on the front of the boiler;no PC DOMESTIC HOT WATER software required. NEW! 0-10V BOILER RATE OUTPUT PRIORITIZATION W/PUMP CONTROL Signal output of modulation rate allows BMS to On DHW call,SMART SYSTEM overrides the LOW-WATER FLOW INDICATOR monitor boiler firing rate. outdoor reset and starts the DHW pump to the Uses temperature differential to protect against indirect water heater alternating to meet both low flow in heat exchanger by reducing heating nd hot water demands. NEW! 0-10V PUMP SIGNAL INPUT g modulation or forcing boiler shutdown. Input from variable speed system pump allows NEW! DHW NIGHT SETBACK faster reaction to changes of flow in system, PASSWORD SECURITY reducing possibility of temperature over-shoot Resets DHW setpoint to save water-heating Allows only qualified personnel to access parameters and cycling. energy during times of low or no usage. NEW! NEW! 0-10V SIGNAL TO CONTROL NEW! PRODUCT SERVICE INDICATOR VARIABLE SPEED BOILER PUMP DHW MAX FIRING RATE Program reminders for cycle count,operation Allows control to maintain a higher AT at low Allows you to limit the maximum percentage of hours or last service.Installer's name and firing rates and reduces boiler flow when it firing rate when in DHW mode. number may be displayed. responds to lower flow rates in the system loop. 5 FLEXIBLE OPTIONS FOR iRECT-VENTING UP TO 100 FEET. Placement of units within a building will never be a problem with KNIGHT. SIDEWALL It permits up to 100 feet of air intake and 100 feet of exhaust vent with VENT 3"PVC,CPVC or stainless steel pipe.Three Wall-Mounted KNIGHT models TERMINATION (WBN 50-105)also permit intake and vent runs up to 40 feet using 2"pipe. ap -_ I FACTORY SUPPLIED AND SHIPPED WITH EVERY MODEL �i � r . iG. x C`V xgr Direct-Vent Vertical Vertical with Sidewall Air Direct-Vent Vertical* Direct-Vent Sidewall* Direct-Vent Sidewall An optional concentric vent kit is sold separately to allow a single penetration for both combustion air and vent pipes. n a. KNIGHT®BOILER DIMENSIONS AND SPECIFICATIONS- FLOOR-STANDING MODELS WALL-MOUNT MODELS I—K 1 ELECiRK:AI. CONNECTIONS4 � T-1rz' H AIR INLET Models: INLET OURET KBN 081.211 T GAB FLUE-/ O AIN INLET 36tH�B,yt FLUE FLu DRA N N y1'NVT SIDE st? ATE N-0A' DRAW 1rl tFA •-1-1K Models: WBN051-211 BACK SIDE FRONT �1N' CONNECTIONS toNraECnoNS I cAs Model: AXt•AET TOP KBN286 ELECTRICAL INLET OUTLET CONNECTIONS F W A GAS - FLUE I N 00 00 F1UE INS'11PT OUTLET .00 CONDENSATE DRAW 13 G 1.014. 4. C' ADJUBTABLE� INLET FE 1N'-1-IN• 611161 D�RN�NENSATE 1s1rr zn D D BOTTOM � R KNIGHT HEATING BOILER r DIMENSIONS AND SPECIFICATIONS Input H o,• e. ty I=B=R A C 1 Conn. WBN051 10 50 95.3 45 39 29-1/4 15-3 4 NA 10.3/4 10 3/4 6 3/4 NA 31/4 41/4 2 3/4 1 1 2 2 130 WBNO81 . 16 80 95.3 72 63 29-1/4 15-3/4 NA 10-3/4 10-3/4 2 6-3/4 NA 3-1/4 4-1/4 2-3/4 1/2 1 2 2 130 WBN106 21 105 95.4 94 82 29-1/4 15-3/4 NA 10-3/4 10-3/4 3-1 5-1/2 NA 3-1/4 4-1/4 2-3/4 1/2 1 2 2 134 WBN151 30 150 95.5 135 119 29-1/4 20-3/4 NA 15 3/4 8112 31Q 51R NA 8-3/4' 9-3/4" 1-1R 1/2 1 3 3 WBN211 42 210 95.7 190 165 29-1/4 25 NA 20r 12 3-1/2 5-1/2 NA 13 14 1-i12 1/2 1 3 3 177 KBNO81 16 80 95.3 72 63 33-i/4 14 573/4 3 20-1/2 22 1-3/4 6-1/2 NA 1/2 1 3 3 125 KBN106 21 105 95.4 94 82 33-1/4 14 6-1/ 5-3/4 4-1/2 1-172 20.1/2 22 1-3/4 6-1/2 NA 1R 1 3 3 129 KBN151 30 150 953 135 119 33-i/4 le 12-1/4 11-1 10 1-3/ 21-1/4 23 l-3/4 12 NA 1/2 1 3 3 157 KBN211 42 210 95.7 190 165 33-1/4 22-1/4 16.112 15-3/4 141/ '31/4--2U14--33 "i-3/4 16-1/4 NA i/2 1 3 3 KBN286 57 285 %.0 260 226 42-1/4' 19-3/4' 12-3/4' 13-i/2' 6' 2' 34' 31' 11-314' 4-1/4' NA 3/4' 1-1/4' 4' 4' 224 Notes:Indoor installation only.All information subject to change.Change'N'to'L for LP gas models. SMART SYSTEM'"FEATURES STANDARD FEATURES >SMART SYSTEM Digital Operating Control )High-Voltage Terminal Strip )Energy StarTM Qualified >Multi-Colored Graphic LCD Display >120 VAC/60 Hertz/1 Phase Power Supply >Up to 96%DOE AFUE Efficiency with Navigation Dial and Soft Keys >Three Sets of Pump Contacts >Modulating Bumer with 5:1 Turndown )Three Setpoint Temperature Inputs >Low Voltage Terminal Strip >Direct-Spark Ignition >Built-in Cascading Sequencer for up to 8 Boilers >24 VAC Device Relay >Low-NOx Operation >Lead Lag >Proving Switch Contacts >Feld Convertible from Natural to LP Gas >Efficiency Optimization >Flow Switch Contacts >ASME Stainless Steel Heat Exchanger >Outdoor Reset Control with Outdoor Air Sensor >Alarm on Any Failure Contacts >30 psi ASME Relief Valve >Programmable for Three Reset Temperature Inputs >Runtime Contacts )Vertical&Horizontal Direct-Vent )Programmable System Efficiency Optimizers >DHW Thermostat Contacts >PVC,CPVC or SS Venting up to 100 feet >Night Setback w/Ovedde Function >3 Space Heat Thermostat Contacts >Factory Supplied Sidewall Vent Termination >DHW Night Setback w/Overide Function >System Sensor Contacts )Smart System Control >Anti-Cycling >DHW Tank Sensor Contacts )Condensate Trap >Outdoor Air Reset Curve >Outdoor Air Sensor Contacts )Other Features >Ramp Delay >Cascade Contacts >Automatic Reset High Limit >Boost Temperature&Time >0-10VDC BMS External Control Contact >Adjustable High Limit w/Manual Reset )Three Pump Control >0•10VDC Boiler Rate Output Contacts >Boiler Circulating Pump >System Pump with Parameter for >0.10VDC Variable Speed System Pump Signal Input >Adjustable Leveling Legs(KB Models only) Continuous Operation >0-10VDC Signal to Control Variable >Wall-Mount Bracket(WB Models only) Boiler Pump with Variable Speed Pump Control* Speed Boiler Pump >Zero Clearances to Combustible Materials >Domestic Hot Water Pump >Modbus Contacts >12-Year Limited Warranty(See Warranty for Details) >Domestic Not Water Prioritization >Time Clock OPTIONAL EQUIPMENT >DHW tank piped with priority in the boiler loop )Data Logging >DHW tank piped as a zone in the system with >Hours Running,Space Heating >Modbus Communication the pumps controlled b the Smart System >Condensate Neutralization Kit P P Y Y >Hours Running,Domestic Hot Water > >DHW Modulation Limiting >Ignition Attempts Flow Switch >Low-Water Cutoff w/Manual Reset&Test >Separately Adjustable SH/DHW Switching Times* >Last 10 Lockouts )Alarm Bell >Building Management System Integration >Access to BMS Settings through Graphic LCD Display >Concentric Vent Kit >0.10VDC Input to Control Modulation or Set Point )Maintenance Reminder >SMART SYSTEM P Software >0-10VDC Modulation Rate Output >Custom Maintenance Reminder with Contractor Info >Stack Frame i >0-10VDC Input Signal from Variable >Installer Ability tope-activate Service Reminder Speed System Pump* >Low-Water Flow Safety Control&Indication FIRING CODES >0-10VDC Input to Enable/Disable call for heat >Dual Level Password Security >M9 Standard Construction *Exclusive feature,available only/rom Lachinvar )Customizable Freeze Protection Parameters >M7 California Code O O g - Lochinvar° Patent Pending M E M B E R cairn Em iengw.eer ueaen,Hoaen er la len i. STATE—OF-THE—ART MODULATING COMBUSTION SYSTEM Advanced Negative Regulation Technology KNIGHT safely and reliably operates with supply gas pressures as low as 4 inches water column. Plus "Neg/Reg" technology i automatically adjusts gas pressure to ensure the correct volume of fuel and air entering the burner. I Direct-Spark Ignition With each call for heat,two electrodes ignite the fuel/air mixture.A third electrode then senses for flame.The SMART SYSTEM will generate a soft lockout and z display a fault if ignition does^' F p y g snot occur after 3 attempts. I Fully Modulating Burner with 5:1 Turndown ► F The SMART SYSTEM allows fully modulating combustion with 5:1jc U V turndown.The burner can fire as low as 20%of maximum input I and modulates the firing rate up to 100%as demand increases. ® A°'' L Awoven stainless steel mesh enclosed burnertube fires in a 3600 s pattern along the entire length of the primary heat exchanger. E Two-in-One Stainless Steel Heat Exchanger A primary heat exchanger combined with a secondary heat exchanger captures flue gas heat and condenses to utilize available latent energy.The stainless steel,pH-tolerant design features a weld-sealed 1 F , assembly with no 0-rings or gaskets and does not require special L' glycol.ASME Section IV approved and stamped. - . = Field Connection Versatility r: User-friendly terminal strip allows for 44 low-voltage Feld connections. Four-line voltage connections supply power to the unit and up to three � � pumps operated by the SMART SYSTEM. x I K TEAM KNIGHT WITH SQUIRE FOR LOW-COST DOMESTIC HOT WATERS KB" 855"°Wn f KNIGHT's Domestic Hot Water Prioritization feature means - you can easily install it with Lochinvar's SQUIRE°indirect water heater, available in 30, 40, 50, 65, 80 and 119 gallons. This combination will give homeowners high- :1 efficiency space heating from KNIGHT, and abundant � i domestic hot water from SQUIRE. With a stainless steel i tank and heat exchanger,SQUIRE provides more hot water ir i . and lower water heating costs than standard gas or electric --— "` water heaters. u � a d