07 -02 -2007 Inspection Request Reporting Page 23
4:31 pm Vail, CO - City of
Requested Inspect Date: Tuesday, July 03, 2007
Inspection Area: CG
Site Address: 100E MEADOW DR VAIL
VAIL PLAZA HOTEL
A/P /D Information
Activity: M06 -0218 Type: B -MECH Sub Type: NCOM Status: ISSUED
Const Type: Occupancy: Use: Insp Area: CG
Owner: DAYMER CORP NV
Contractor: CCOLLO FIREPLACE SUPPLY (ZINK HOLDINGS Phone: (303) 255 -8220
Description: VAIL HOTEL - INSTALLATION OF THE MONTIGO GAS FIREPLACES AND HEAT & GLO LOBBY
FIREPLACE
Requested Inspection(s) 7 03.
Item: 390 MECH -Final Requested rVn ( 02:00 PM
Requestor: Mark - Shaw Phone: 477 -4710
Assigned To: JMONDRAGON ' Entered By: DGOLDEN K
Action: Time Exp:
Comment: UEVLL 19U-b b N81 ,616.
LEVEL 200 -B 707,715,718,719. LEVEL 210 -B 808,
LEVEL 220 -B 902 904 916 917 918 920.
Comment: LEVEL 180 -A UNITS �28,�32,�42,�47
Comment: LEVEL 200 -A 728,729,732,734.
Comment: LEVEL 190 -A 622 625 627 629
Comment: LEVEL 200 -A UNITS �22,�24,Y25,727 728.
Comment: LEVEL 210 -A UNITS 825,826,827 DIDNT LIGHT. UNITS 822,823 APPR.
, �At
Inspection History
Item: 200 MECH -Rou h
10110106 Inspector: GCD Action: NO NOTIFIED
Comment: WALK THRU WITH LARRY AND TODD; OPEN CHASE FOR INSPECTIONS. MOCK UP UNITS
APPEAR TO MEET VENT GRAPH.
10/13/06 Inspector: GCD Action: PI PARTIAL INSPECTION
Comment: LEVEL 180A UNITS 532,542,547 APPR
LEVEL 190A UNITS 625.639 REMOVE INSULATION FROM VENT
10/18/06 Inspector: GCD Action: PI PARTIAL INSPECTION
Comment: MIN CLR TO COMBUSTIBLES HAD NOT BEEN MET. CORRECTION WERE MADE AND
REINSPECTED SAME DAY.
10/24/06 Inspector: GCD Action: PI PARTIAL INSPECTION
Comment: LEVEL 180 -A UNIT 528, LEVEL 190 -A UNITS 622 627.
10/25/06 Inspector: GCD Action: PI PAikTIAL INSPECTION
Comment: LEVEL 200 -A UNITS 724,725,734 VENTING AND INSTALLATION APPR
11/06/06 Inspector: NSC Action: PI PARTIAL INSPECTION
Comment: partial approval on 821,826,732,729 728,727 fireplace vent and installation.
11/13/06 Ins ector: GCD Action: G`R CORRECTION REQUIRED
Comment: 1.E INSPECTION REQD FOR ALL POWER VENT FIRE PLACES.
2.UNIT 726 VENT TERMINATION REQD TO BE 18" MIN TO WALL.
3.NO FLEX VENT OVER X ALLOWED.
4.827 VENTING INSTALLATION APPROVED. NEED ELECT.
12/08/06 Inspector: GCD Action: PI PARTIAL INSPECTION
Comment: ELECTRICAL INSPECTION PERFORMED BUILD A UNITS
REPT131 Run Id: 6840