HomeMy WebLinkAboutM05-0125 inspection 11-20-2006 Inspection Request Reporting Page 29 4:43 pm Vail, CO - Citv Of � Requested Inspect Date: Tuesday, November 21,2006 Inspection Area: CG 5ite Address: 20 VAIL RD VAIL SONNENALP HOTEL ADDITION A/P/D Information Activity: M05-0125 Type: B-MECH Sub Type: ACOM Status: ISSUED Const Type: Occu ancy: Use: Insp Area: CG Owner: SONNENALP PROPERTI�S INC Applicant: MTECH MECHANICAL TECHNOLOGIES Phone: (303)650-4000 GROUP,INC Contractor: MTECH MECHANICAL TECHNOLOGIES Phone: (303)650-4000 GROUP,INC Description: INSTALL ALL NEW HVAC SYSTEMS Requested Inspection(s) Item: 390 MECH-Final Requested Time: 08:30 AM Requestor: MTECH MECHANICAL TECHNOLO I Phone: 401-0077 GROUPINC Assigned To: JMOND�2AGON Entered By: DGOLDEN K Action: Time Ex : Comment: 6. Comment: Units 319 4�21 &431 Comment: BALANC� REPORT RECEIVED. UNIT FINALS 320 321 322 323 324 325 327,328 329,330 332 333. UNDERC(JT.THE�2E dDA(�UA'fE F�ETIJRN AIR�ROM N�ASYER BEDROOM TO FCU WITH 1"DOOR SPA DUCT WRAP APPROVED. Comment: 334 MECH FINAL 422 BATH EXHAUST CONNECTED. 430 MECH FINAL Comment: Unit 422-Exhaust fan is missing the cover. Unit 425-A.)Need access to disconnect at fan coil. B)Need access to remove fan coil without removing permanent construction. Units 423 and 434 are ok. Comment: 422I BATH EXHA�ST�OV�3RE�D 1,424,427,428,429 Comment: CORRECTIONS FROM 02-01-06 APPROVED. - UNIT 529 RETURN AIR FOR FCU IN LIVING ROOM? Comment: UNIT 535 Comment: 1.CAP ALL DUCTS THRU WALLS ON UNFINISHED SIDE AS NOTED ON 022106. 2.RETURN AIE IS REQD FOR 2 OFFICES. 3.PROVIDE BALANCE REPORT. 4.ALL PENETRATIONS REQD TO BE FIRE STOPPED ON BOTH SIDES OF SEP WALL. Comment: UNIT 435 Comment: 524 NOT T-STAT 526 COMPLETE FINAL INSTALLATION AND COVERS. 529 NOT READY 525 APPR Comment: Reinspection Required- 1)supply duct passes through fire-rated wall in office. Needs a damper or be removed.2.)Comp�ete insulation of oufside air duct above office. First 3-4 feet from outside wall is not insulated. 3:)Verity with Greg D.-4 blocked off supply ducts which pass through rated walls. Ducts will need to be sealed at all ends(no openings). Comment: Back of House Corrections complete Comment: Balance report recieved for back of house. See file Comment: Labels missing from access panels located on level 3,4&5 Obtain engineer approval for fire damper location and installation at the elevator equipment room at Talisman �U�O�C�lC,��lS �yVl IF�C�� , � r,�►,� a�'�� ��r� �- Dr�-►� � , Inspection Historv ����� ��. Item: 200 MECH-Rou h "`Approved"` V ° 08/31/0� Ins ector: GCD ctio � AR IAL INSPECTION Comment: GA�AGE SNOWMELT& HYDRONI PPLY AND RETURN LINES ON Z LINE FROM 111 TO 0 LINE. 100psi TEST. 09/28/05 Inspector: GCD Action: PI PARTIAL INSPECTION Comment: HOT AND CHILLED WATER SUPPLY AND RETURN MAINS AND RISERS 100psi TEST. UNITS 323 THRU 329 AND 423 THRU 429 11/02/05 Inspector: GCD Action: PI PARTIAL INSPECTION Comment: GARAGE SNOWMELT AND HYDRONIC SUPPLY AND RETURN MAINS FROM 111 LINE TO REPT131 Run Id: 5990