Loading...
HomeMy WebLinkAboutE05-0112 inspection . .i► 11-24-2006 Inspection Request Reporting Page 40 3'31 �m Vail, CO - Citv Of Requested Inspect Date: Monday, November 27,2006 Assigned To: SHAHN Inspection Type: ELEC Inspection Area: CG 5ite Address: 20 VAIL RD VAIL SONNENALP ADDITION A/P/D Information Activity: E05-0112 Type: B-ELEC Sub Type: ACOM Status: ISSUED Const Type: Occu ancy: Use: Insp Area: CG Owner: SONNENALP PROPERTI�S INC Applicant: ENCORE ELECTRIC Phone: 970 949-9277 Contractor: ENCORE ELECTRIC Phone: 970 949-9277 Description: ADD ELECTRIC FOR NEW PARKING STRUCTURE AND NEW W NG O EXISTING HOTEL Requested Inspection(s) Item: 190 ELEC-Final Requested Time: 09:30 AM Requestor: ENCORE ELECTRIC/Steve Phone: 970-401-0715 Comments: Will call Steve 401-0715/Sonnenalp Assigned To: SHAHN Entered By: LTILLMAN K Action: Time Exp: Comment: Comment: UNIT 426 FINAL� Comment: FINAL UNIT 319. Comment: UNIT 431 FINAL APPROVED Comment: ROUGH INSPECTED FOR 4TH FLOOR 3RD CORRIDOR 2ND CORRIDOR. DEFECTIVE FSD ON 3RD FLOOR. DAMAGED SEALTITE OUYSIDE ROOFHAT�H. ROOFTOP UNITS REQUIRE LOCKABLE DISCONNECT SIWTCH. Comment: 326 423 422,430 434 Comment: �NS�EC'TED PAF�KING AREA AND EXIT STAIRWELLS FOR EGRESS LIGHTING, EXITS,AND WITNESSED GENERATOR START. Comment: FINAL UNITS 433,420. Comment: final unit 419 and 432 Comment: FINAL 321 322,323,324,327,328,329,330,332,333,AND 334. Comment: FINAL UNI'fS 336 AND 436. Comment: EXCLUDING 4TH FLOOR ELEVATOR LOBBY. 4TH FLOOR CORRIDOR CEILING APPROVED. I �Z/��� ' �2"��`'� 529 CEILING ONLY. . UNITS 421,424,425,427,428,429,325,331,320. Comment: UNIT 326 GFI RECEPTACLE IN BATH NOT WORKING. C Comment: FINAL 5 NH COR�DbR� � Comment: FINAL UNIT 529. �� `' Comment: final unit 535. Comment: UNIT#435 CORRECTION APPROVED. Comment: UNIT 435 GFI FOR HEAT MAT NOT WORKING IN SW BATH. Comment: FINAL FOR BACK OF HOUSE OFFICES. Comment: electrical for Swiss House approved. Kitchen duplex receptacles for POS equipment have been mounted at same height as convenience receptacles.To reduce hazard if POS is not plugged into correct receptacles, make alI in kitchen GFIC. Inspection Historv Item: 110 ELEC-Service 05l12/06 Inspector: shahn Action: PI PARTIAL INSPECTION Comment: approved restaurnat walls only. 05/25/06 Inspector: shahn Action: PI PARTIAL INSPECTION Comment: 400A/3restaurnat service approved. 06/15/06 Inspector: shahn Action: PI PARTIAL INSPECTION Comment: approved meter service and panel in Verbatun Bookstore. approved kitchen above ceiling. Support troffers under MAU from structure. Item: 120 E�EC-Rough "'Approved"' 07/26/05 Inspector: , shahn Action: PA PARTIAL APPROVAL Comment: inspected lines 106 to the east on plaza level. 0?/28/05 Insp ector: SHAHN Action: AP APPROVED Comment: INSPECTED EAST BRANCH UNDERGROUND FOR TALSMAN REPT131 Run Id: 6004