HomeMy WebLinkAboutB05-0026 inspection B05-0026: Entries for Item:90 - BLDG-Final 14:20 04/25/2013 Action Comments By Date Unique_ Ke PI CORRECTIONS: FOR ALL UNITS GUARDS GCD 12/20/2005 A000086 EXCEED MAX 4"SPACING. UNIT 320 DOOR 626 SMOKE SEAL REQD, REUSED DOOR NO SAFETY GLAZING BUG. UNIT 323 REUSED DOOR GLAZING BROKEN NO SAFETY GLAZING BUG. UNIT 332 DOOR DOESN'T LATC H. 2nd FLOOR UNITS 322,324,325,326,327,328,329,330,331,332, 333,334. 3rd FLOOR UNITS 423,424,425,427,428. RECEIVED LETTER REGARDING SAFETY _ GLAZING IN FILE PI Unit 320-Safety Glazing issue still remains on MROYER 12/21/2005 A000086 exterior doors.Smoke seal installed. Unit 323 642 and 332-ok. Looked at 4 other units on the 4th floor that were not read for ins ection. PA UNIT FINALS 323,422,422,429,430. GCD 12/22/2005 A000086 UNIT 321 694 1.32"MIN @ BATHROOM DOOR. 2.SOAP DISH OVER 48"MAX 3.SHOWER CONTROL SHOULD NOT REQ TIGHT GRASP OR TWISTING. PA Units finals for 319,421,431 cdavis 12/27/2005 A000086 761 PI UNIT 419 CORRECTIONS NO SAFETY GCD 12/30l2005 A000086 GLAZING AT BALCONY DOOR AND 843 SHOWER, FIRE ALARM NOT COMPLETE UNIT 420 NO SAFETY GLAZING AT BALCONY DOOR. UNITS 432,433 APPR FIRE ALARM MAY NOT BE COMPLETE. CR CORRECTIONS FROM 12-30-05 NO GCD 01/03/2006 A000086 COMPLETED. 885 NOTED DOORS BEING MOVED TO 5th FLOOR IN EXISTING SOUTH STAIR. CONFIRMED ELEVATOR IS NOT OPERATIONAL. NO ALL UNITS REQUIRE VFES APPROVAL GCD 01/04/2006 A000086 PRIOR TO OCCUPANCY 886 PA UNITS 419,420,432,433,336 BEDROOM GCD 01/10/2006 A000086 WINDOW REQD TO MEET 20"MIN 999 EGRESS,426 APPR. PI UNITS 335,436 GCD 01/11/2006 A000087 034 PA UNIT 435 GCD 01/18/2006 A000087 208 PI UNITS 519,524,525,529.APPROVED GCD 02/02/2006 A000087 LETTER FROM KONNEN GLASHAUS 480 REGARDING SAFETY GLAZING RECEIVED AND IN FILE. PI ADA REQUIREMENTS NOT MET: INSTALL GCD 02/15/2006 A000087 GRAB BARS, LAV APRON REQD TO BE 27" 683 MIN, INSULATE TRAP AND HOT SUPPLY. PA UNIT 535 IS APPROVED FOR GCD 02/16/2006 A000087 OCCUPANCY. REINSPECTION IS REQD 719 WHEN DROP DOWN GRAB BAR IS ___ INSTALLED. PA UNIT 535 GCD 02/17/2006 A000087 739 DN 1.EXTERIOR/ACCESS NOT COMPLETE. GCD 02/27/2006 A000087 2.FIRE ALARM FINAL REQD. 864 3.BALANCE REPORT AND MECH ITEMS REQ FINAL. FIRE STOPPING AND ADA INSIDE APPROVED. Page 1 _ _ B05-0026: Entries for Item:90 - BLDG-Final 14:20 04/25/2013 CR TALISMAN STAIRS HANDRAILS DO NOT GCD 11/16/2006 A000095 MEET CODE FOR HEIGHT.ADD HANDRAIL 809 ON ONE SIDE SHORT FLIGHT. EXHAUST FOR ELEVATOR EQUIPMENT REQUIRES REVIEW BY ENGINEER FOR FIRE DAMPER LOCATION. FIRESTOP HEAD OF WALL. ITEMS APPROVED GATE INSTALLED (NEED PERMENANT SIGN). BENCHES DO NOT OBSTRUCT EXIT DISCHARGE. HANDRAIL IN BREEZEWAY RAMP INSTALLED. DOWN SPOUTS APPROVED. TRANSFORMER AND DOGHOUSE PAINTED. AP All Corrections identifed are completed cdavis 11/21/2006 A000095 See TCO ent 11/21/06 945 Total Rows: 17 Page 2