Loading...
HomeMy WebLinkAboutA13-0023 DATA SHEETS Honeywell VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL — i � � ��� � , �t, � �� . , � ° �� :_�,. --- ,.��' �`.. , �' �.�� Now UL864 9th Edition Approved The new VISTA-128FBP provides the ultimate protection of initiating devices, notification circuits, communication devices, life and property.This UL Listed commercial fire and burglary keypads, RF receivers and relays are also supported. The control panel supports up to eight partitions and up to 128 VISTA-128FBP has been designed to mount quickly and zones/points using hardwired, wireless and V-Plex° easily in an attack resistant cabinet, and is available in 12V addressable technologies. A diverse line of Honeywell and 24V models. FEATURES • Eight hardwired zones standard, • Supports V-Plex addressable • Supports Internet and GSM expandable to 120 V-Plex VISTAKEY access control alarm reporting� addressable points/zones or (1 to 8 doors) • Supports graphical user interfaces 128 wireless points/zones .Two on-board notification (bell) for burglary use • Can control eight separate areas circuits delivering 2.3A @ 12V . Supports 6160CR-2 multi-LED independently(8 partitions) •Automatic smoke detector sensitivity fire keypad • Supports commercial wireless fire maintenance testing . Listed to UL864 9th Edition and burglary devices • Four-wire smoke reset using . Upload/download via Ethernet` • Stores up to 512 events onboard J2 output trigger • Carbon monoxide (CO) •Accommodates 150 user codes • Supports Dynamic Signaling for zone support and up to 250 access card holders AlarmNet Communicators using VISTAKEY�' � When used with AlarmNet devices. VISTA°-128FBPN128FBP-24 Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Notification Appliance Circuits(two): -Individually assignable to any of - Eight zone-Class B expander module eight partitions - Programmable - Single-zone supervised contact module -Up to 16 two-wire smoke detectors each -Temporal code compliant • UL Listed wireless expansion on zone one and two(32 total) - Individually silenceable - Supports up to 128 wireless zones/points -Up to 50 two-wire glassbreak detectors • Programmable on-board auxiliary relay on zone eight - Supervised by control for check-in signals • False alarm reduction features: • Patented addressable V-Plex polling -Tamper protection for transmitters - Exit error logic loop technology - Individually assignable up to eight partitions - Exit delay reset - Supports 120 two-wire zones points - Supports commercial wireless smoke -Cross zoning - Global polling technology for faster detectors processing • Up to eight doors using VISTAKEY V-Plex -Call waiting defeat - Supervised by panel Access Control - Recent close report -Zones individually assignable to • Event reporting • Supports commercial hardwired, partitions, notification circuit(bell)output addressable V-Plex�' ollin loo and • Local printer for event log printing P g P or auxiliary relay wireless zones •Communication - 4,000 ft.capability without the use of • Hardwired zones shielded cable - Phone line, GSM and IP communicator - Provides ei ht st le B hardwired zones support 9 Y - Extender/Isolation bus modules -EOLR su ervised for Fire and UL bur la - Panel operation during download p 9 ry - Eight zone-Class A and B expander installations-Supports N.O.or N.0 sensors module Honeywell SPECIFICATIONS Applications Main Dialer Agency Listings The VISTA-128FBP control is well suited • Line seize: Double Pole • UL609 Grade A Local Mercantile for a variety of applications as an Premises and Mercantile Safe and Vault • Ringer equiv: 0.7B integrated fire and burglary control. Some of the applications supported are: • Formats: ADEMCO�Low Speed, • UL611/1610 Grades A, AA, Central medical and professional buildings, ADEMCO 4+2 Express, ADEMCO High Station churches or synagogues, office buildings, Speed, ADEMCO Contact ID, Sescoa • UL365 Grades A, AA Police Connect schools, strip malls, larger residences and Radionics • UL864/NFPA72 Local, Central and factory or warehouse environments. gackup Communication Station and Remote Station Electrical • Dual phone line capability using • UL985 • Primary power: 18VAC @ 72VA 5140DLM module • Factory Mutual Honeywell No. 1451 •AlarmNet"GSM, i-GSM and IP • California State Fire Marshal • Control panel quiescent current draw: Communicators 300mA • MEA Cabinet Dimensions • Backup battery: • CAN/ULC S304—Central and • 18" Hx14.5"Wx4.3"D Monitoring Station Burglar Alarm Unit - 12VDC, 12AH min to 34.4AH max Environmental • CAN/ULC S527—Central Unit for Fire - Lead acid battery(gel type) . Storage temp: 14° F to 158° F Alarm Systems •Alarm power: 12VDC, 1.7A max for (-10° C to 70° C) each notification (bell) circuit output • CAN/ULC S303—Local Burglar • Operating temp: 32° F to 122° F Alarm Unit Total 2.3A 12V (0° C to 50° C) • CAN/ULC S525—Audible Signal •Aux. standby pwr: 12VDC, 1A max . Humidity: 85% RH Appliances •Total power: 2.3A at 12VDC . EMI: Meets or exceeds the following • Standby time: 24 hours with 1A requirements: standby load using 34.4AH battery - FCC Part 15, Class B Device • Fusing: Battery input, aux. and - FCC Part 68 notification (bell) circuit outputs are protected using PTC circuit protectors. - IEC EMC Directive All outputs are power limited. • Optional 24-volt kit VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices •4208SNF Class A/B Expander Module • 5806W3 - Photoelectric Smoke • 6160CR-2 - Red Fire Keypad •4190SN Remote Point Module- Detector • 6160- Burglary Keypad two zones • 5809 -Wireless Heat Detector • 4204- Relay Module,four form •4193SN and 4193SNP Two-zone • 5817CB -Wireless Commercial C contacts Expander Modules Transmitter • 4204CF-Two supervised output V-Plex Extender/Isolation Modules • 5869 - Hold-Up Transmitter circuits •4297 Extender/Isolator Module • 5881 ENHC- RF Receiver • 5881 Series RF receiver •VSI Isolator Module • 5883H - RF Receiver • 5883H RF receiver V-Plex Smoke Detectors Access Control • 6220S -System printer used with � 4100SM serial module • 5193SD • VISTAKEY" V-Plex(addressable) •5193SDT Access Control Two-Wire Smoke Detectors • VISTAKEY-SK Starter Kit Conventional V-Plex Passive Infrared Detectors . VISTAKEY-EX Expansion Kit • System Sensor •998MX • ESL • IS2500SN Alarm Communications • DSC • DT7500SN • 7845i-ENT- Internet/Intranet Communicator Horn/Strobes V-Plex(Addressable)Contacts • 7845GSM - Digital Cellular • System Sensor •4939SN-WH Communicator • Wheelock •4944SN-WH • 7845i-GSM - Internet and Digital • Gentex •4959SN Cellular Communicator Manual Pull Stations V-Plex Glassbreak Detectors • GSMCF/iGSMCF- Commercial Fire • FG1625SN Communication Kits(when available) • 5140MPS-1 • IPGSM-DP Internet and Digital Cellular • 5140MPS-2 Optional 24V Kit Communicator V-Plex(Addressable) Devices • Order number: V128FBP924KT •4208U Universal Eight-zone Expansion Commercial Wireless Devices Module • 5808W3- Photoelectric Smoke/Heat • 4101 SN Single Relay/Zone Module Detector Product specifications subject to change. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information:www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 Honeywe" P.O. Box 9040 Melville, NY 11747 wsrA,zaFaPOi� 1.800.467.5875 september 20�2 www.honeywell.com OO 20�2 Honeywell International Inc. 5881ENHC COMMERCIAL WIRELESS RECEIVER The new 5881 ENHC RF Receiver is designed for use with transmitters operating at 345 MHz. The receiver also features control panels that are approved for use in commercial fire a Spatial Diversity System that virtually eliminates "nulls" and and/or burglary installations.The receiver recognizes alarm, "dead spots"within the coverage area. status and keypad control messages from wireless FEATURES • Front and back tamper for commercial • Spatial Diversity System virtually •Compatible with all 5800 series fire/burg installations eliminates"nulls" and "dead spots" wireless devices within the coverage area •One or two receivers can be used to • Connects to control panel via the provide redundant coverage or extend • Can be mounted remotely, keypad bus coverage in large areas anywhere on the keypad bus, for extended coverage • UL listed for Commercial Fire/Burg applications COMPATIBLE CONTROLS • VISTA-32FB • VISTA-128FBP •VISTA-250FBP • FA1700 series • VISTA-128BP • VISTA-250BP • FA1600 series SPECIFICATIONS Dimensions Interface Wiring Installation • 7-3/8" W x 4-3/8" • RED: 12VDC input(+)Aux. power • See product installation instructions for (10-7/8" with antennas) H x 1-7/16" D details on programming and mounting 188mm W x 112mm H • GREEN: Data out to control (277mm with antennas)x 37mm D .YELLOW: Data in from control UL Listings Input Voltage •Commercial Fire UL 864 • FM • BLACK: Ground(-) • 12VDC(from control's keypad terminals) • Household Fire UL 985 • MEA Range Current • Household Burg UL 1023 • CSFM •200 ft (60m) nominal indoors from • 60mA(typical) wireless transmitters(the actual range •Commercial Burg UL 365, Operating Temperature to be determined with the security UL 609, UL 1076, UL 1610 •32° F to 122° F system in the Test mode) (0° C to 50° C) ORDERING 5881 ENHC Commercial Wireless Receiver Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywe" P.O. Box 9040 Melville, NY 11747 veaaiENHCio www.hone well.com o�tober2ooa y OO 2008 Honeywell International Inc. 6160CR-2 i :�;.�:}:�:�:,�_,w��������:�..+::�: _ F'E�E:��r° T�:.� �1Fh1 COMMERCIAL FIRE ALPHA KEYPAD - --- -^��-- UL864 REV 9 LISTED �`'� �` '"; , ' `" ': ri..,...FIRd _ POEICF i I .:� hW'AY ,A..._. { . .. . ; � . ..... . .._ ...._. ..�. �,,. ...: . ... .:. . .. ."., . ..' . . .. � :,'I( ... ' � The 6160CR-2 is an addressable remote keypad intended is backlit only when a key is depressed'`, or when the for use in commercial fire applications with Honeywell's system is in alarm or trouble condition. commercial fire control panels. The keys are continuously �Note:The LCD may be programmed to remain on at all times(see panel backlit for convenience and easy visibility. The LCD display instructions for details). FEATURES • Four programmable • Seven Status LEDs • Large easy-to-read display function keys —Armed (Red) • Built-in sounder — Ready (Green) • Red removable door — Power (Green) • Physical — Fire Alarm (Red) 5.250" W x 7.437" H x 1.312" D —Silenced (Yellow) —Supervisory (Yellow) —Trouble (Yellow) SPECIFICATIONS Sounder Compatibility • High-quality speaker • Supports Control Panels Electrical —VISTA-32FB Rev 5 and higher —VISTA-128FBP Rev 4 and higher • 45mA standby 160mA in alarm (sounder, back light and —VISTA-250FBP Rev 4 and higher LED on) UVCUL and residential Listed for commercial fire and burglary installations. To be employed with manufacturer's listed control units as indicated in the installation instructions. Product specifications subject to change. ORDERING 6160CR-2 Commercial Fire Alpha Keypad For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications HonG��ll 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 v6i socRZOi� September 2009 www.honeywell.com OO 2009 Honeywell International Inc. 5821 WIRELESS TEMPERATURE SENSOR AND FLOOD DETECTOR Honeywell's 5821 is a versatile wireless device that can be configured to operate as either a standalone temperature sensor and/or a remote temperature sensor or flood detector. It is ideally suited for a wide range of applications including bathrooms, laundry rooms and basements. FEATURES • Five selectable temperature ranges • Flood detection with 470PB External • Completely wireless, which greatly to choose from (hot, warm, cold, Probe for a wide range of reduces installation time and refrigerate and freeze) applications; including bathrooms, maximizes placement options • Remote Temperature Probe available �aundry rooms and basements . Capable of monitoring cold (T280R) ideal for refrigerator and • Up to 10 year battery life, which (45° F)temperature and flood freezer monitoring reduces user maintenance detection simultaneously SPECIFICATIONS Sensor Parameters • "Swinger Suppression" (Hysteresis) Range of Response time • Cold Temperature Detector 45° F of 3° F • +50%, -20% —Temperature difference between —When temperature drops below -10 minute setting (8-15 min) 45° F for>10 minutes fault and restore points -30 minute setting (24-45 min) •Warm Temperature Detector 75° F Power Dimensions —When temperature rises above • One 3V battery(included) 75° F for>10 minutes • 1.6" W x 3.1" H x 1.0" D • Replace only with ADEMCO #466, (max protrusion) • Hot Temperature Detector 95° F Panasonic CR123A, Sanyo CR123A, . 40.64mm x 78.74mm x 25.4mm —When temperature rises above Duracell DL123A, Tekcell CR123A 95° F for>10 minutes or Varta CR123A(Lithium Compatibility Manganese Dioxide) • Refrigerator Failure Detector 42° F • Compatible with all 5800 series —When temperature rises above Operating Temperature wireless receivers 42° F for>30 minutes . 14° F to 104° F(-10° C to 40° C) Agency Listings • Freezer Failure Detector 10° F —When temperature rises above Operating Frequency • FCC Part 15 10° F for>30 minutes • 345 MHz±85 KHz • DOC RSS-210 • Flood Sensor —When 1/4" inch of water is covering the 470PB probe ORDERING �� ,� 5821 Wireless Temperature Sensor& Flood Detector ���� �_ � ' T280R External Probe for Freezer and Refrigeration Monitoring � � 470PB External Probe for Flood Sensing T280R 470PB Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywe" P.O. Box 9040 Melville, NY 11747 www.hone well.com u5az,io y September 2008 OO 2008 Honeywell International Inc. �� SYSTEM =� �� ��� SENSOR� � � � � � �� � = E ` . _ '��� Outdoor Selectable .� � Output Horns, -_ � ry �S -- Strobes, and � --�— Horn Strobes for - Wall Applications SPECTR�ert SpectrAlert�Advance outdoor audible visible products a n v .ea n� c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options, and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30, 75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela, automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage. Once the plates are mounted,ail SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING "^ corrosion. Knock-outs located on the back eliminate the need to drill O� �`�°� holes for screw-in mounting. Plastic and metal weatherproof back �R boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED F M MEA �300-1653187(outdoor s�robes) a roved 775-,653,8acno��st�ob�s, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S401 i(chlmes,hom strobes,homs) /PPROVEO pP chlme strobes) S3593(outdoorandalertstrobes) 302357? MFA452-05-F 7135-1653�189(homs,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit�M Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-voit-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. .- . Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6`L x 4.7"'W x 2.5"'D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"'W x 1.3"'D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7""L x 5.1""W x 2.0""D(145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2. P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data . . 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 1�� NA NA 281 251 185 NA NA 286 258 � 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 � .. 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed .- • candela ratings must be reduced in accordance with •g-175 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic "- � � ' Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low �5 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9� Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. nvoso,zo, SpectrAlert Advance Diagrams �4.7" 2.5" ��� ��,.»R � ��� �� ��� �!� � 5.6" ° O 0 � � � � Wall-Mount Horn Strobes � � Wall Plastic Weatherproof Back Box 1� 0 �� � p � ��� � � � Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information .- Wall Horn Strobes P2RK"t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK"t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK`t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK`t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t SVobe,Standard cd, Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe, High cd,Red,Outdoor(includes plastic weatherproof back box) SWK"t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK"t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95, 11Q and 115 candela settings."High cd"refers to strobes that include 135,150, 177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. l\��� �STEM 002012 System Sensor. �� 1 ✓/�� 3825 Ohio Avenue•St.Charles, IL 60174 P�oducis�ecit�icationssubjeatochanyewahoutnotice,Visitsystemse�soccom ��y� SE/VSORr Phone:800-SENSOR2•Fax:630-377-6495 forcurrentproductinformatio�,mdudi��gme�atestve�sionotmisdatasheet. AVDS01201•3/12