HomeMy WebLinkAboutB13-0114 plans Electrical drawings APPROVEDSC
A
L
E
:
1
EL
E
C
T
R
I
C
A
L
D
E
M
O
P
L
A
N
1/
4
"
=
1
'
-
0
"
SC
A
L
E
:
2
EL
E
C
T
R
I
C
A
L
F
L
O
O
R
P
L
A
N
1/
4
"
=
1
'
-
0
"
PANEL:EM1CAVOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:250 LOCATION:BOILER ROOMMAIN:MLO MOUNTING:MINIMUM AIC:NO.LOADTYPELOAD DESCRIPTIONBREAKERBUSBREAKERTYPELOAD DESCRIPTIONLOADNO.ABCPOLETRIPABCTRIPPOLEABC 1 (E)SB-1315+153(E)SB-223+4 5+6 7 PUMP #1 (1 1/2 HP)315+8 9+201(E)EXH-110 11+201(E)CONTROLS12 13(E)CONDENSATE TANK FILL115+153(E)SB-31415(E)BLOW DN CONTROL115+16 17(E)CHEM FEED PUMP115+18 19(E)BLOW DN CONTROL115+201(E)SB-3 CONTROLS20 21 PUMP #2 (1 1/2 HP)315+201(E)EPO CONTROLS22 23+153MPUMP #3 (2 HP)24 25+M26 27FEED WATER TANK CONTROL PANEL220+M28 29+30 LOAD TYPEPANEL TOTALFEED THRU TOTALSUBFEEDTOTALFEEDERSUBTOTALDEMANDFEEDER TOTALGENERAL NOTES:A.(L) LIGHTING00125%0B.(R) RECEPTACLES00NEC 2200C.(LM) LARGEST MOTOR0025%0D.(M) MOTORS (ALL)00100%0E.(E) EQUIPMENT00100%0SPECIFIC NOTES:(A) APPLIANCES0000(1)PANEL TOTAL (KVA):0.0(2)(3)PANEL TOTAL (A):0(4)(5)LOAD SUMMARY for EM1CA (250AMP, 208/120 VOLT, 3‐PHASE)30 DAY METERING MAX DEMAND15.70A 5.65KVA LOAD ADDED MOTORS2.81KVA EQUIPMENT1.25KVA SUBTOTAL4.06KVA LOAD BEFORE NEC DEMAND FACTOR9.71KVA NEC DEMAND FACTOR1.25%NEC CORRECTED LOAD12.14KVA TOTAL AMPS34AMPS EM1CA FEEDER RATING50AMPS
(E
)
P
A
N
E
L
'
E
M
1
C
A
'
PU
M
P
S
P
-
1
&
P
-
2
(
1
-
1
/
2
H
P
)
,
FO
R
S
B
-
1
&
S
B
-
2
F
E
E
D
WA
T
E
R
T
A
N
K
.
S
A
L
V
A
G
E
PU
M
P
S
F
O
R
U
S
E
I
N
N
E
W
LO
C
A
T
I
O
N
W
I
T
H
N
E
W
T
A
N
K
.
PU
M
P
P
-
3
(
2
H
P
)
,
F
O
R
S
B
-
3
FE
E
D
W
A
T
E
R
T
A
N
K
.
D
E
M
O
FE
E
D
E
R
F
R
O
M
P
A
N
E
L
'
E
L
2
B
'
.
SA
L
V
A
G
E
P
U
M
P
F
O
R
U
S
E
I
N
NE
W
L
O
C
A
T
I
O
N
W
I
T
H
N
E
W
TA
N
K
.
EX
I
S
T
I
N
G
P
A
N
E
L
'
E
M
1
C
A
'
.
PU
M
P
P
-
4
(
2
H
P
)
,
F
O
R
S
B
-
3
F
E
E
D
WA
T
E
R
T
A
N
K
.
D
E
M
O
F
E
E
D
E
R
F
R
O
M
PA
N
E
L
'
E
L
2
B
'
.
S
A
L
V
A
G
E
A
L
L
P
U
M
P
EQ
U
I
P
M
E
N
T
,
R
E
T
U
R
N
T
O
O
W
N
E
R
F
O
R
FU
T
U
R
E
U
S
E
.
(N
)
T
R
I
P
L
E
X
C
O
N
T
R
O
L
PA
N
E
L
F
O
R
F
E
E
D
WA
T
E
R
P
U
M
P
S
.
(E
)
P
-
1
(
1
-
1
/
2
H
P
)
,
C
O
N
N
E
C
T
P
U
M
P
TO
N
E
W
C
O
N
T
R
O
L
P
A
N
E
L
.
(E
)
P
-
2
(
1
-
1
/
2
H
P
)
,
C
O
N
N
E
C
T
P
U
M
P
TO
N
E
W
C
O
N
T
R
O
L
P
A
N
E
L
.
(E
)
P
-
3
(
2
H
P
)
,
C
O
N
N
E
C
T
PU
M
P
T
O
N
E
W
C
O
N
T
R
O
L
PA
N
E
L
.
GENERAL NOTES:
1.
E
L
E
C
T
R
I
C
A
L
W
O
R
K
O
V
E
R
V
I
E
W
:
T
W
O
B
O
I
L
E
R
F
E
E
D
TA
N
K
S
W
I
L
L
B
E
R
E
M
O
V
E
D
.
E
A
C
H
F
E
E
D
T
A
N
K
H
A
S
TW
O
P
U
M
P
S
.
T
H
E
R
E
I
S
O
N
E
B
O
I
L
E
R
F
E
E
D
P
U
M
P
T
A
N
K
RE
P
L
A
C
I
N
G
T
H
E
T
W
O
T
A
N
K
S
.
T
H
R
E
E
P
U
M
P
S
F
R
O
M
PR
E
V
I
O
U
S
F
E
E
D
T
A
N
K
S
Y
S
T
E
M
W
I
L
L
B
E
R
E
-
U
S
E
D
I
N
ON
E
T
R
I
P
L
E
X
C
O
N
T
R
O
L
S
Y
S
T
E
M
W
I
T
H
T
H
E
N
E
W
F
E
E
D
TA
N
K
.
C
O
N
T
R
A
C
T
O
R
T
O
D
I
S
C
O
N
N
E
C
T
A
N
D
RE
C
O
N
N
E
C
T
P
U
M
P
S
I
N
N
E
W
C
O
N
F
I
G
U
R
A
T
I
O
N
.
2.
D
O
N
O
T
S
C
A
L
E
D
R
A
W
I
N
G
S
.
V
E
R
I
F
Y
D
I
M
E
N
S
I
O
N
S
O
N
AR
C
H
I
T
E
C
T
U
R
A
L
D
R
A
W
I
N
G
S
A
N
D
I
N
F
I
E
L
D
P
R
I
O
R
T
O
CO
M
M
E
N
C
E
M
E
N
T
O
F
W
O
R
K
.
3.
V
I
S
I
T
S
I
T
E
P
R
I
O
R
T
O
B
I
D
A
N
D
V
E
R
I
F
Y
T
H
A
T
CO
N
D
I
T
I
O
N
S
A
R
E
A
S
I
N
D
I
C
A
T
E
D
.
C
O
N
T
R
A
C
T
O
R
SH
A
L
L
I
N
C
L
U
D
E
I
N
H
I
S
B
I
D
C
O
S
T
S
R
E
Q
U
I
R
E
D
T
O
MA
K
E
H
I
S
W
O
R
K
M
E
E
T
E
X
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
.
4.
S
Y
S
T
E
M
O
U
T
A
G
E
S
S
H
A
L
L
B
E
P
E
R
M
I
T
T
E
D
O
N
L
Y
A
T
TI
M
E
S
A
P
P
R
O
V
E
D
B
Y
O
W
N
E
R
-
I
N
W
R
I
T
I
N
G
.
W
O
R
K
WH
I
C
H
C
O
U
L
D
R
E
S
U
L
T
I
N
A
N
A
C
C
I
D
E
N
T
A
L
O
U
T
A
G
E
(B
E
Y
O
N
D
B
R
A
N
C
H
C
I
R
C
U
I
T
S
)
S
H
A
L
L
B
E
P
E
R
F
O
R
M
E
D
WI
T
H
T
H
E
O
W
N
E
R
'
S
M
A
I
N
T
E
N
A
N
C
E
P
E
R
S
O
N
N
E
L
AD
V
I
S
E
D
O
F
S
U
C
H
W
O
R
K
.
5.
S
E
R
V
I
C
E
S
H
A
L
L
B
E
M
A
I
N
T
A
I
N
E
D
T
O
E
X
I
S
T
I
N
G
A
R
E
A
S
DU
R
I
N
G
C
O
N
S
T
RU
C
T
I
O
N
.
6.
W
O
R
K
S
H
A
L
L
B
E
P
E
R
F
O
R
M
E
D
I
N
A
W
O
R
K
M
A
N
L
I
K
E
MA
N
N
E
R
T
O
T
H
E
S
A
T
I
S
F
A
C
T
I
O
N
O
F
T
H
E
O
W
N
E
R
.
7.
W
O
R
K
,
M
A
T
E
R
I
A
L
S
,
A
N
D
E
Q
U
I
P
M
E
N
T
S
H
A
L
L
CO
N
F
O
R
M
T
O
T
H
E
L
A
T
E
S
T
E
D
I
T
I
O
N
S
O
F
L
O
C
A
L
,
ST
A
T
E
O
F
C
O
L
O
R
A
D
O
,
A
N
D
N
A
T
I
O
N
A
L
C
O
D
E
S
A
N
D
OR
D
I
N
A
N
C
E
S
.
8.
P
R
O
V
I
D
E
P
E
R
M
I
T
S
A
N
D
I
N
S
P
E
C
T
I
O
N
S
R
E
Q
U
I
R
E
D
.
9.
C
O
N
T
R
A
C
T
O
R
'
S
F
A
I
L
U
R
E
T
O
O
R
D
E
R
O
R
R
E
L
E
A
S
E
OR
D
E
R
F
O
R
M
A
T
E
R
I
A
L
S
A
N
D
/
O
R
E
Q
U
I
P
M
E
N
T
W
I
L
L
NO
T
B
E
A
C
C
E
P
T
E
D
A
S
A
R
E
A
S
O
N
T
O
S
U
B
S
T
I
T
U
T
E
AL
T
E
R
N
A
T
E
M
A
T
E
R
I
A
L
S
,
E
Q
U
I
P
M
E
N
T
,
O
R
IN
S
T
A
L
L
A
T
I
O
N
M
E
T
H
O
D
S
.
10
.
V
E
R
I
F
Y
E
X
A
C
T
L
O
C
A
T
I
O
N
S
O
F
E
X
I
S
T
I
N
G
A
N
D
N
E
W
UN
D
E
R
G
R
O
U
N
D
U
T
I
L
I
T
I
E
S
,
P
I
P
I
N
G
A
N
D
R
A
C
E
W
A
Y
SY
S
T
E
M
S
P
R
I
O
R
T
O
T
R
E
N
C
H
I
N
G
.
P
R
O
V
I
D
E
NE
C
E
S
S
A
R
Y
T
R
E
N
C
H
I
N
G
,
B
A
C
K
F
I
L
L
,
E
X
C
A
V
A
T
I
O
N
,
SU
P
P
O
R
T
S
,
S
E
R
V
I
C
E
F
E
E
D
E
R
S
(
C
O
N
D
U
I
T
A
N
D
/
O
R
WI
R
E
)
,
P
U
L
L
B
O
X
E
S
,
S
A
W
C
U
T
T
I
N
G
A
N
D
P
A
T
C
H
I
N
G
,
CO
N
C
R
E
T
E
/
P
A
V
I
N
G
,
E
T
C
.
R
E
Q
U
I
R
E
D
.
B
A
C
K
F
I
L
L
TR
E
N
C
H
E
S
T
O
9
0
P
E
R
C
E
N
T
C
O
M
P
A
C
T
I
O
N
A
N
D
P
A
T
C
H
TO
M
A
T
C
H
E
X
I
S
T
I
N
G
.
11
.
F
I
E
L
D
V
E
R
I
F
Y
E
X
I
S
T
I
N
G
E
Q
U
I
P
M
E
N
T
O
R
C
I
R
C
U
I
T
S
TH
A
T
A
R
E
R
E
M
A
I
N
I
N
G
T
O
B
E
R
E
C
O
N
N
E
C
T
E
D
T
O
N
E
W
OR
E
X
I
S
T
I
N
G
S
W
I
T
C
H
B
O
A
R
D
S
/
P
A
N
E
L
B
O
A
R
D
S
.
PR
O
V
I
D
E
S
W
I
T
C
H
E
S
,
R
E
C
E
P
T
A
C
L
E
S
,
C
O
N
D
U
I
T
,
W
I
R
E
,
ET
C
.
A
S
R
E
Q
U
I
R
E
D
,
T
O
R
E
S
T
O
R
E
C
O
N
T
I
N
U
I
T
Y
O
F
CI
R
C
U
I
T
(
S
)
.
12
.
E
X
I
S
T
I
N
G
S
Y
S
T
E
M
S
A
N
D
C
O
N
D
I
T
I
O
N
S
S
H
O
W
N
O
N
DR
A
W
I
N
G
S
F
O
R
E
X
I
S
T
I
N
G
B
U
I
L
D
I
N
G
S
A
R
E
T
O
B
E
NO
T
E
D
“
F
O
R
G
U
I
D
A
N
C
E
O
N
L
Y
”
.
T
H
E
E
L
E
C
T
R
I
C
A
L
CO
N
T
R
A
C
T
O
R
T
O
F
I
E
L
D
C
H
E
C
K
A
L
L
E
X
I
S
T
I
N
G
CO
N
D
I
T
I
O
N
S
P
R
I
O
R
T
O
B
I
D
D
I
N
G
A
N
D
T
O
I
N
C
L
U
D
E
I
N
HI
S
B
I
D
A
N
A
L
L
O
W
A
N
C
E
F
O
R
R
E
M
O
V
A
L
A
N
D
/
O
R
RE
L
O
C
A
T
I
O
N
O
F
E
X
I
S
T
I
N
G
C
O
N
D
U
I
T
S
,
W
I
R
E
S
,
DE
V
I
C
E
S
,
F
I
X
T
U
R
E
S
,
O
R
O
T
H
E
R
E
Q
U
I
P
M
E
N
T
A
S
INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED 13.PROVIDE ELECTRICAL DEMOLITION REQUIRED.REFER TO MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS.14.PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES,RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED.15.EQUIPMENT BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED.16.VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.17.REVIEW MECHANICAL DRAWINGS.18.INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.19.FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.20.CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.21.WHERE THE RE-USE OF EXISTING CONDUITS, WIRES,DEVICES, ETC, IS PERMISSIBLE, MAKE CERTAIN THAT THE WIRING FOR SAME IS CONTINUOUS.22.ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.23.ALL WIRING SHALL BE INSTALLED IN LISTED RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM CONDUIT SIZE IS 3/4”.FOLLOW NEC FOR MAXIMUM NUMBER OF CONDUCTORS PER CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO ELIMINATE THE NEED TO DE-RATE CONDUCTORS. METAL CLAD CABLE IS NOT PERMITTED.24.RACEWAYS BELOW GRADE TO BE PVC SCHEUDULE 40. RACEWAYS WITHIN BUILDING SHALL BE EMT.SURFACE MOUNTED EXTERIOR CONDUIT TO BE GRC.25.ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT.26.WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING SHALL BE COPPER.SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT.CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS.27.PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT.28.PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS.29.FINAL CONNECTIONS TO MOTORS, TRANSFORMERS,AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.30.ALL OUTLETS TO BE LABELED (WITH CLEAR TAPE AND BLACK TEXT) WITH PANEL AND POLE DESIGNATION.31.SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER.32.GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER.33.SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION.34.MAINTAIN A CURRENT SET OF AS-BUILT RECORD DRAWINGS WHICH SHALL BE AVAILABLE FOR REVIEW DURING ENGINEER'S SITE OBSERVATIONS. UPON COMPLETION, PROVIDE RECORD DRAWINGS TO ARCHITECT. DRAWINGS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS,REROUTINGS, ETC.
P 1
P 2
P 3
P 4
P 1
P 2
P 3
EM
1
C
A
-
2
7
,
2
9
(C
O
N
T
R
O
L
P
A
N
E
L
PO
W
E
R
)
RO
U
T
E
P
U
M
P
F
E
E
D
E
R
T
H
R
O
U
G
H
I
N
T
E
G
R
A
T
E
D
ST
A
R
T
E
R
I
N
T
R
I
P
L
E
X
C
O
N
T
R
O
L
P
A
N
E
L
.
R
E
F
E
R
T
O
CO
N
T
R
O
L
P
A
N
E
L
S
U
B
M
I
T
T
A
L
(
W
I
R
I
N
G
D
I
A
G
R
A
M
)
FO
R
F
U
R
T
H
E
R
D
E
T
A
I
L
S
.
1
FL
A
G
N
O
T
E
S
:
1
EM
1
C
A
-
7
,
9
,
1
1
EM
1
C
A
-
2
1
,
2
3
,
2
5
EM
1
C
A
-
2
4
,
2
6
,
2
8
VAIL, COLORADO 8739.37 SHEET TITLE:NO.Job no.:ISSUE Drawn by:Date:Designed by:DATE BY BOILER FEED TANK REPLACEMENT VAIL VALLEY MEDICAL CENTER EAUDIN ANZECOPYRIGHT 2013 BG
C:\Users\cadd-txc\local settings\temp\AcPublish_5076\873937E10.dwg Printed By: cadd-txc April 18, 2013 - 10:09am LC-XXX
Vail:Denver:Fort Collins:Albuquerque:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 Reviewed by:KEY PLAN1OWNER REVIEW04.10.13 JSB 04.18.132PERMIT04.18.13 JSB E1.0ELECTRICALFLOOR PLANSMASMASMAS (E) STEAM PLANT LOCATION.By lcampbell at 4:13 pm, Apr 19, 2013