EXISTING FLOOR -
JOISTS WITH OUTRI
DECK JOISTS
Iill UP ON J I
EXISTING DECK
JOISTS
X1 NEW (3)2X6
UP ONL
NEW (3) -5 1/2" LVL
BEAM ON FLOOR
V M
APR = 2013
.TIL
TOWN OF VAIL
J
Monroe &Newell SUN VAIL UNIT 21A TITLE: PARTIAL FLOOR FRAMING PLAN
605 NORTH FRONTAGR ROAD WEST
Engineers, Inc. VAIL, COLORADO
P.O. Box 1597 DATE: 4 -10 -2013
70 Benchmark Road, Suite 204 S1
Avon, Colorado 81620
(970) 949 -
FAX (970) 949 -44054 054 NO. #9163 SCALE: 1/2" = 1' -0" DRAWN BY: AVN
EMAIL avon @monroe- newell.com
4
b
1'J
D' 4
7
EXISTING FLOOR -
JOISTS WITH OUTR
DECK JOISTS
X2
-NEW (3) X6
COLUM
-4 -H,515-4X-4 /4E5
RE: SEC.
EXISTING DECK
JOISTS
NEW -2X6 AT 1' -4" -
EXTERIOR STUD
INFILL WALL
/—NEW (5)--2X&
COLUMN
NEW (5)--2X& HEADER
Monroe & Newell SUN VAIL UNIT 21A TITLE: PARTIAL CEILING FRAMING PLAN
605 NORTH FRONTAGR ROAD WEST
Engineers, Inc. VAIL, COLORADO
P.O. Box 1597 DATE: 4 -10 -2013 C 2
70 Benchmark Road, Suite 204 J
Avon, Colorado 81620
(970) 949 -7768
FAX (970) 949 -4054 NO. #9163 SCALE: 1/4" = 1' -0" DRAWN BY: AVN
EMAIL avon @monroe- newell.com
6
NEW EXTERIOR 2X6
AT 1' -4" STUD HALL
WITH 1/16" PLYWOOD
SHEATHING AT EXTERIOR
AND 5/8" GYP. SHEATHING
AT INTERIOR
NEW 3/4" OR 5/8"
PLYWOOD FLOOR
SHEATHING- NAIL
AND GLUE TO EXISTING
DECGING- INSTALL
LE\/EL HITH EXISTING
INTERIOR FLOOR
SHEATHING
EXISTING DECKING
eEC�T ION X1
1 1/2" = 1' -0"
NEW (3) -5 112" LVL
FLOOR BEAM IN HALL
NAIL NEW HALL
SHEATHING TO RIM
JOIST HITH 8d X 1 112"
NAILS AT 6"
EXIST
AND I
OF UN
NEW F
WITH,
WITH
RODE
TO BE
NEW I
PLAT
LAG-
SECTION AT
BEAM END
&EC�TION X2
- IEATHING
'ROOFING
Monroe & Newell SUN VAIL UNIT 21A TITLE: DETAILS
605 NORTH FRONTAGR ROAD WEST
Engineers, Inc. VAIL, COLORADO
P.O. Box 1597 DATE: 4 -10 -2013 C
70 Benchmark Road, Suite 204 J
Avon, Colorado 81620
(970) 949 -7768
FAX (970) 949 -4054 NO. #9163 SCALE: 1/4" = 1' -0" DRAWN BY: AVN
NA EMAIL. avonCo monroe- newell.com
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT TUBE MEMBEERS
WHICH SHALL CONFORT TO ASTM A500, GRADE B, LATEST EDITIONS. STEEL SUPPLIER
MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS -D1.1.
E. MINIMUM WELDS TO BE PER AISC TABLE 32.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
6. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. WATERPROOFING, VAPOR BARRIERS, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
C. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS.
D. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.
Monroe & Newell SUN VAIL UNIT 21A TITLE: GENERAL NOTES
605 NORTH FRONTAGR ROAD WEST
Engineers, Inc. VAIL, COLORADO
P.O. Box 1597 DATE: 4 -10 -2013 ��
70 Benchmark Road, Suite 204
Avon, Colorado 81620
(970) 949 -7768
FAX (970) 949 -4054 NO. #9163 SCALE: 1/4" = 1' -0" DRAWN BY: AVN
EMAIL. avon @momoe- newell.com
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
4. WOOD
A.
EXTERIOR DECK 100 PSF
A.
ALL FRAMING LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
B.
TYPICAL FLOOR 40 PSF
BUILDING CODE AS FOLLOWS:
C.
ROOF <4:12 SLOPE 100 PSF
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSI
D.
WIND
5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSI
3 SECOND GUST 90 MPH
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITVE USES PRIOR
FASTEST MILE 85 MPH
TO ALLOWABLE STRESS INCREASES.
EXPOSURE B
B.
WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
E.
LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
F.
CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2012 EDITION.
C.
TREATED SILL PLATE LUMBER MAY BE HEM -FIR, STRUCTURAL #1 GRADE.
2. TESTING, INSPECTIONS AND OBSERVATIONS:
D.
FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304 -9.1 UNLESS NOTED OTHERWISE.
A.
THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
E.
PLYWOOD DECK AND /OR ORIENTED STRAND BOARD.
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
ASSOCIATION.
BUILDING CODE.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE - TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
B.
THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
1. STEEL CONSTRUCTION
WEATHER SHALL BE OF THE EXTERIOR TYPE.
a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION
3. FOR FLOORING USE 3/4" T &G STURD -I -FLOOR SHEATHING GLUED AND NAILED
EXCEPT THE FOLLOWING:
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
INTERMEDIATE SUPPORTS.
ACCORDANCE WITH SECTION 1704.3.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
OSB SHEATHING NAILED WITH 8d NAILS AT 6" ON CENTER ALONG PANEL
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
SHALL BE BLOCKED.
VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE
6. FLOOR SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
WELDING.
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
5. NON- STRUCTURAL ELEMENTS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
A.
ELEMENTS SUCH AS NON- BEARING PARTITIONS, ETC. ATTACHED TO AND /OR
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
OTHER STRUCTURAL MOVEMENTS.
e. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGH
STRENGTH BOLTS.
B.
FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
3. STRUCTURAL STEEL
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT TUBE MEMBEERS
WHICH SHALL CONFORT TO ASTM A500, GRADE B, LATEST EDITIONS. STEEL SUPPLIER
MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS -D1.1.
E. MINIMUM WELDS TO BE PER AISC TABLE 32.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
6. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. WATERPROOFING, VAPOR BARRIERS, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
C. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS.
D. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.
Monroe & Newell SUN VAIL UNIT 21A TITLE: GENERAL NOTES
605 NORTH FRONTAGR ROAD WEST
Engineers, Inc. VAIL, COLORADO
P.O. Box 1597 DATE: 4 -10 -2013 ��
70 Benchmark Road, Suite 204
Avon, Colorado 81620
(970) 949 -7768
FAX (970) 949 -4054 NO. #9163 SCALE: 1/4" = 1' -0" DRAWN BY: AVN
EMAIL. avon @momoe- newell.com