HomeMy WebLinkAboutA13-0024 CUT SHEETS.pdf Si►ispl�x�rin►�t�►► 6240 Smith Road Denver, Colorado 80401 Sales: (303) 355-0500 Service: (303) 355-0500 Fax: (303) 355-0615 PROJECT: vai� VAI L PREPARED FOR: vA�� TYPE: DESCRIPTION: 4010-9401 4010ES FIRE CONTROL PANEL 4010-9912 SERIAL DACT 4190-6104 TRUE INSIGHT REMOTE SERVICE 2081-9276 BATTERY 12V 33AH 4606-9102 REMOTE LCD ANNUNCIATOR 4099-9003 MANUAL STATION - DOUBLE ACTION 4098-9714 PHOTO SENSOR 4098-9733 HEAT SENSOR 4098-9792 SENSOR BASE 4098-9798 SSD SOUNDER BASE W/CO MODULE 4905-9835 TEMPORAL CODE 4 MODULE 4098-9794 SENSOR BASE W/SOUNDER 4098-9754 PHOTO SMOKE SENSOR W/HEAT 4098-9795 DUAL ADDRESS SOUNDER BASE 4098-9756 DUCT SENSOR HOUSING-4-WIRE 2098-9806 REMOTE TEST STATION 4098-9857 SAMPLING TUBE 46"TO 71" 4090-9001 SUPERVISED IAM 4090-9002 RELAY IAM 4009-9201 NAC EXTENDER 120VAC, IDNET 4009-9807 NAC CARD, 4PT, IDNET 2081-9275 BATTERY 18AH 4906-9129 HORN/STROBE MC WHITE 4906-9130 HORN/STROBE MC WHITE CEILING 4906-9131 WP HORN/STROBE MC RED 4905-9828 WP A/V BACKBOX RED �oSimplEx 4010m Fire Control Panels UL, ULC, CSFM Listed; Addressable Fire Detection and Control FM, NYC Fire Dept Approved* Basic Panel Modules and Accessories � Basic system includes: • Capacity for up to 248 addressable devices,up to � '� � 127 VESDA SLl points,up to 2000 points of r---�.--. �� Annunciation and up to 20 internal and external card ���� addresses � � ���� � • Color-coded operator interface with membrane �pIIII�VI�lllll@lU�lllllll�lllllll�lllllll�l�llllll�lllllll�ll keypad includes 2 x 40 Super-twist LCD display, 3 programmable control keys and 6 programmable LEDs • CPU assembly includes dedicated compact flash 4010ES Fire Alarm Control Panels are available memory for on-site system information storage and standard (left)or with LED Annunciation (right) convenient Ethernet service port access • 8 A power supply with up to 2 A of Auxiliary power and battery charger capacity for up to 110 Ah batteries COmpatlble Wlth SlmpleX° remOtely IOCated: (UL)or up to 50 Ah batteries(ULC)(33 Ah max in • 4098-9757 QuickConnect 2 and legacy 4098-9710 control panel cabinet) QuickConnect TrueAlarm smoke sensors • 4 on-board Class A or B, 3 A NACs and one • 4003EC Small Voice Panels programmable auxiliary relay output rated far . 4009 IDNet NAC Extenders(4009A) 2 A@ 32 VDC . TrueAlert Addressable Controllers(4009T)and • Class A ar B Two-loop Isolated IDNet Remote TrueAlert Power Supplies(4009 TPS) Communications(IDNet+)supports up to . 4081 Series, 110Ah Battery Chargers 248 addressable and analog sensing devices on . 4100-7400 Series Gra hic Annunciators non-twisted,non-shielded wiring p • Remote annunciator module support via RUI(Remote • 4190 Series PC Annunciator Unit Tnterface)communications port,supports either • 4190 Series Fiber Modems and Physical Bridges Class B(Style 4)or X(Style 7)Pathway operation . 4606-9102 Remote LCD Annunciator,4100-9400 • 48 LED panel mount annunciation provides 40 Red Series Remote InfoAlarm Command Centers, and and 8 Yellow pluggable LEDs(select models,meets 4602 Series Status Command Units(SCU)and ULC requirements),optional LED kits are available Remote Command Units(RCU)Annunciators for custom LED configurations • IP communicator compatibility Optional Main System Supply and door 4010ES Agency listings: mounted modules include: UL Std. 864,Fire Detection and Control (UO7z),and • City Connect(with or without disconnect switches) � Smoke Control Service(iT[JKL),and Releasing • Alarm Relay Module Service(SYZV) • Truelnsight Remote Gateway . UL Std.2017,Process Management Equipment Optional block space modules include: (QvAx) • Fire Alarm Network Interface Card for 4120/4100 . UL Std. 1076,Proprietary Alarm Units-Burglar Peer-to-Peer network communications,supports either (APOU) Class B or X(Sryle 7)Pathway operation . UL Std. 1730, Smoke Detector Monitor(UULH) • Ethernet connectiviry options include Building . ULC Std. 5527-99,Fire Detection and Control Network Interface Module(BNIC), SafeLINC Internet (UOJZC) Interface,and BACpac Ethernet Partal . ULC Std. 5559-04, Supervising Starion(DAYRC) • Dual RS-232 Module(for printer,PC annunciator or third parry interface) • VESDA A1T'f�S 1T'atlOri HI Il L,2V01 IritOI'faCO ' See pages 5 and 6 for additional listing informatioa This product has been approved by p g the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California • Serlal DACT Health and Safety Code.See CSFM Listing 7165-0026:0369 for allowable values andlor conditions concerning material presented in this tlocument.It is subject to • 8 ZOrie IDC l�/IOCIUIeS C11SS f�OT'B re-examination,revision,and possible cancellation.NYC Fire Dept COA#6095. Additional listings may be applicable;contact your local Simplex product supplier for the • 4 POII]t l�uXl�laY'y RO�ay MOClU10 latest status.Listings and approvals under Simplex Time Recorder Co.are the property . Physical Bridge Network Modules of Tyco Fire Protection Products. S4010-0004-7 1/2013 . . . . • -. 4010ES Series Fire Detection and Control Panels 4010ES Block Space Option Cards mount to the left provide leading edge installation,operator,and service of the 4010ES Main System Supply.There are 3 available features for customer applications in the mid-range 4"x 5"blocks for mounting 4010ES hardware options. addressable fire alarm systems market.An on-board Other 4010ES Options: The 4010ES City Connect Ethernet port provides fast external system communications to expedite installation and service module or the optional Alarm Relay module mount activity. Dedicated compact flash memory archiving directly to the Main System Supply.These options are provides secure on-site system information storage of mutually exclusive. electronic job configuration files to meet NFPA 72 Network Media modules mount directly to the 4010ES (National Fire Alarm and Signaling Code)requirements. Network Interface Card. Modular design.A variety of functional modules are The TrueInsight Remote Gateway mounts on the back available to meet specific system requirements. Selections side of the 4010ES User Interface Panel. allow panels to be configured for either Stand-Alone or The Battery Compartment located in the bottom of Networked fire control operation. the 4010ES cabinet accepts two batteries,up to 33 Ah, . . without interfering with expansion module space. The Master Controller and Main System Supply The illustrations below identify mounting locations are mounted in tbe upper section of the 4010ES cabinet. available for optiona14010ES modules. ; 4"x 5" Main System Truelnsight Remote 3 available 4"x 5�� �BlockA Supply Gateway mounts on block spaces for � - ••° the back of the 4010ES � a°x a° ; a°x e° ; � `� User Interface Panel additional option cards , �Block B i Block D; �—--—--'--——--—� uaiioiiooiouoiooiuuoiuoiiooioouiuoiuouiouiiooi000iuoi000iuoiuoi Mounting Locations for Optional Modules � . . . • Mounting box provides convenient stud markers for • TrueAlarm individual analog sensing with front panel drywall thickness and nail-hole knockouts for quicker information and selection access mounting . "Dirty"TrueAlanm sensor maintenance alerts,service • Smooth box surfaces are provided far locally cutting and status reports including"almost dirry" conduit entrance holes exactly where required . TrueAlarm magnet test indication appears as distinct • The hinged User Interface panel easily opens for "test abnormal"message on display when in test mode internal access . TrueAlarm sensor peak value performance report • Modules are power-limited(except as noted,such as . ��Install Mode"allows grouping of multiple troubles relay modules) for uninstalled modules and devices into a single • Doors include tempered glass inserts,boxes and doors trouble condition(typical with future phased are available in platinum ar red expansion);with future equipment and devices • Box and door/retainer assemblies are included with grouped into a single trouble,operators can more Basic Panel assemblies clearly identify events from the commissioned and occupied areas • Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring • "Recurring Trouble Filtering"allows the panel to recognize,process,and log recurring intermittent troubles(such as external wiring ground faults),but only sends a single outbound system trouble to avoid nuisance communications • WALKTEST silent or audible system test performs an automatic self-resetting test cycle 2 S4010-0004-7 1/2013 • . . • Convenient and extensive operator information is Convenient Status Information.With the locking provided using a logical,menu-driven display door closed,the glass window allows viewing of the display, status LEDs,and available operator switches. • Multiple automatic and manual diagnostics for Features include a two-line by 40-character,wide viewing maintenance reduction angle(super-twist)LCD with status LEDs and switches as • Convenient PC programmer label editing shown in the illustration below. • Password access control LED indicators describe the general category of activiry being displayed with the LCD providing more detail. For • Alarm and Trouble History Logs(up to 2000 total the authorized user,unlocking the door provides access to events)are available for viewing from the LCD,or the control switches and allows further inquiry by capable of being printed to a connected printer,or scrolling the display for additional detail. downloaded to a service computer The following illustration identifies the primary functions of the operator interface. FIRE ALARM ACK acknowledges a Fire Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priority 2 Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory ULC SYSTEMS 6 SYSTEM STATUS INDICATOR LEDs provide contlitions,logs the acknowletlge,and silences the require designating system status indications,LEDs flash to indicate operator panel and all annunciator tone-alerts a Grountl Fault a change in status and remain on-steady after TROUBLE ACK acknowledges system trouble indicator acknowledged until reset conditions,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts ALARM SILENCE causes audible notification 2 X 40 LCD READOUT,LCD is appliances to be silencetl(depending on panel 3 PROGRAMMABLE LEDs backlighted during normal conditions, programming)typically after evacuation is complete and two selectable as Red or Yellow, provides up to 40 characters for custom while alarm source is being investigated;may allow one selectable as Green or Yellow label information visible notification to continue(strobes still flashing) FIRST ALARM DISPLAY operation can SYSTEM RESET restores control panel to normal when Custom label insert be selected for maintained display of first all alarmed inputs are returned to normal alarm until acknowledged �b watert�ow-east •=�1�•=�TEM I:=� IAII_�Fih'IAL 1:�a���rt t� n�r� FRI �4-J'Al�f-1:= Waterflow-West Ground Fault - City Disconnect Elevator Bypass I Ground Fault Latch � � • • � � � ES 3 PROGRAMMABLE POINT STATUS ADDITIONAL FUNCTION LCD NAVIGATION NUMERIC KEYPAD for FUNCTION SWITCHES CONTROL KEYS: KEYS: CONTROL: point category and point with yellow LED Point Enable and Event Time Request Menu selection selection(alphabet intlicators Disable More Information Request Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position this time) Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode 3 S4010-0004-7 1/2013 • • . • • � - The 4010ES is compatible with an extensive list of remote Status is determined by comparing the current sensor peripheral devices including printers,PC Annunciators and value to its average value.Tracking this average value as both conventional and addressable devices including a continuously shifting reference point filters out TrueAlarm analog sensors. environmental factars that cause shifts in sensitivity. � • . - , . - � - . . Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke Overview.The 4010ES provides standard addressable obscuration(shown directly in percent)or for specific device communications for IDNet compatible devices. heat detection levels. To evaluate whether the sensitivity Using a two wire communications circuit,individual should be revised,the peak value is stored in inemory and devices such as manual fire alarm stations,TrueAlarm can be easily read and compared to the alarm threshold sensors,conventional IDC zones,and sprinkler waterflow directly in percent. switches can be interfaced to the addressable controller to communicate their identity and status. CO sensor bases combine an electrolyric CO sensing Addressability allows the location and condition of the module with a TrueAlarm analog sensor to provide a connected device to be displayed on the operator interface single multiple sensing assembly using one system LCD and on remote system annunciators.Additionally, address. The CO sensor can be enabled/disabled,used in control circuits(fans,dampers,etc.)may be individually LED/Switch modes and custom control, and can be made controlled and monitored with addressable devices. public for communication across a fire alarm Network. (refer to data sheet 54098-0041 for details) Addressable Operation. Each addressable device on the communication channel is continuously interrogated TrueAlarm heat sensors can be selected for fixed for status condition such as:normal,off-normal,alarm, temperature detection,with or without rate-of-rise supervisory,or trouble.Both Class B and Class A detection.Utility temperature sensing is also available, pathway operation are available. Sophisticated poll and typ�cally to provide freeze warnings or alert to HVAC response communication techniques ensure supervision system problems.Readings can be selected as either integrity and allow for"T-tapping"of the circuit for Fahrenheit or Celsius. Class B operation. Devices with LEDs pulse the LED to TrueSense Early Fire Detection.Multi-sensor indicate receipt of a communications poll and can be 4098-9754 provides photoelectric and heat sensor data turned on steady from the panel. using a single 4010ES IDNet address. The panel evaluates IDNet+ Channel CapaCity. The Main System Supply smoke activity,heat activity,and their coinbination,to provides an IDNet+signaling line circuit(SLC)that provide TrueSense early detection. For more details on supports up to 248 addressable monitor and control this operation,refer to data sheet 54098-0024. devices intermixed on the same pair of wires. � . � � , � � _ � . � _ IDNet+ Communications wiring specifications. IDNet+circuits may be run on NEC 760 untwisted pair, Sensor Status. TrueAlarm operation allows the control twisted pair,or shielded twisted pair conductors. panel to automatically indicate when a sensor is almost dirty,dirty,and excessively dirty. The NFPA 72 IDNet+Wiring Specifications requirement for a test of the sensitivity range of the Size 18 AWG(0.82 mm�) sensors is fulfilled by the ability of TrueAlarm operation Type NEC 760 Wire(untwistetl,twisted, to maintain the sensitivity level of each sensor. CO or shielded twisted pair) Sensors track their 5 year active life status providing Farthest Distance 126-248 Up to 2500 feet(762 m) indicators to assist with service planning.Indicators occur from Control Panel at: ] year,6 months,and when end of life is reached. per Device load up to 125 Up to 4000 ft(1219 m) Modular TrueAlarm sensors use the same base and Up to 12,500 ft(3.8 km) different sensor types(smoke or heat sensor)and can be Total Wire Length Allowetl Class Note:The sum of line-to-line easily interchanged to meet specific location requirements. A or Class B,including"T-taps" capacitance plus the capacitance for Class B wiring(total for both of either line-to-shield(if shield is This allows intentional sensor substitution during building isolated circuits combinetl) present)=0.6 NF inaximum(total construction when conditions are tempararily dusty. for both isolated circuits combined) Instead of covering smoke sensors(causing them to be *Other circuits may require shielded wiring.Review your system with disabled),heat sensors may be installed without your local Simplex product supplier. reprogramming the control panel. The control panel will indicate an incorrect sensor type,but Y11e heat sensor will - � • • - • operate at a default sensitivity to provide heat detection for building protection at that location. Addressable device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condirion and the CPU maintains a current value,peak value,and an average value for each sensor. 4 S4010-0004-7 1/2013 • • � - � • • The 401 OES Master Controller includes dedicated 4010ES panels include: an Operator Interface,Master 2GB compact flash Mass Storage memory for on-site Controller with 2GB Compact Flash, Class A or B Two- system information storage and convenient Ethernet loop Isolated IDNet Communications(IDNet+) service port access supporting up to 248 addressable and analog sensing • Convenient front panel accessed Ethernet port for devices, 8 A power supply with up to 2 A of auxiliary quick and easy download of site-specific power, 110 Ah(UL)/50 Ah(ULC)battery charger programming (33 Ah maximum in the control panel cabinet),4 Class A or Class B NACs rated @ 3 A each for Special • AND,firmware enhancements are made via software Application and 2 A for Regulated 24 DC operation, downloads to the on-board flash memory 1 programmable auxiliary relay rated for 2 A@ 32 VDC, • Every downloaded job is automatically stored to 1 RUT Class B or X communications port for remote Compact flash without overwriring earlier versions annunciation devices,cabinet,and door. providing a means for recovering previous configurations Support is for up to 20 internal and external card addresses. Other standard options may be provided • Downtime is reduced because the system stays depending on model (see basic panel model selection running during download below for additional details on specific models). • Modifications can be uploaded as well as downloaded for greater service flexibility ' ' • Mass Storage allows job specific files to be store in The Main System Supply provides the power source and the control panel such as test and inspection reports, the Input/Output connections for the basic 4010ES panel. record drawings, specifications,and more... The main features are listed in the Basic Panel description • Ethernet connectivity options include Building below. Network lnterface Module(BNIC)and SafeLINC InYernet Interface • RUI(Remote Unit Interface)communications port supparts either Class B or X Pathway operation far remote annunciation equipment and for 4009 Series TrueAlert Controllers and TrueAlert Power Supplies . . . Note: Supervisory and Alarm current specifications are for determining battery standby requirements. Current specifications include an active RUI channel and alarm currents include 20 IDNet device LEDs activated.Actual IDNet channel device current is not included, refer to page 6 for details. For models with 48 LED Annunciation, alarm also includes 24 LEDs activated. Panel Language& Supv. Alarm Available Model" Color Voltage Listings Features Current Current Option Blocks 4010-9401(BA) Red Basic panel with 2x40 LCD Operator English UL, CSFM, FM, �nterface and (1)Two-loop Isolated 120 VAC NYC Fire Dept IDNet+Channel, Class A or B,with 316 mA 430 mA 4010-9402(BA) Platinum support for up to 248 addressable devices 3 4010-9403(BA) Red English UL, ULC, 4"x5" 120 VAC CSFM, FM, blocks 4010-9404(BA) Platinum NYC Fire Dept Same features as above with 48 LED 336 mA 495 mA annunciation 4010-9405 Red French ULC,CSFM, 4010-9406 Platinum 120 VAC FM *Models with(BA)are available as assembled in the USA by adding the suffix"BA". 5 S4010-0004-7 1/2013 � • • . • - � - • . • • - • • • • Addressable Channel Device Load Supervisory Alarm Current Current With 248 Devices,Add 199 mA 248 mA Main System Supply IDNet+Channel Output With 125 Devices,Add 100 mA 125 mA (does not include device LEDs in alarm) With 50 Devices,Add 40 mA 50 mA • • . • • • • • Note: Refer to diagram on page 2 for Option Module availability. Supervisory and Alarm current specifications are for determining battery standby requirements. Single Block Option Modules, Select Three(3) Maximum if No Dual Block Module is Selected; Select One(1) Maximum if a Dual Block Module or the Module Bracket is Selected Model Features Option Block Usage Supervisory Alarm Current Current 1 Block 4010-9912 Serial DACT (must mount in block D 30 mA 40 mA under main system supply) 4010-9908 4 Point Aux Relay Module 1 Block 15 mA 60 mA Voltage Regulator Module,22.8 to 26.4 VDC 4.9 A (25 VDC nominal); isolated and resettable output; 3 A maximum 4010-9916 includes earth detection circuit and trouble relay 1 Block with 2.5 A load maximum for status monitoring with 4 A load 4010-9918 Dual RS-232 Module 1 Block 60 mA 60 mA 4010-9915 BACpac Ethernet Portal Module; requires 1 Block 123 mA 123 mA 4010-9918 RS-232 Module(no address required) 4010-9901 VESDA HLI 1 Block 60 mA 60 mA Dual Vertical Block(Flat) Modules, Select One, or Two with 4010-9928 Bracket Kit(except for Media Cards) Model Features Option Block Usage Supervisory Alarm Current Current Dual Vertical Block Card Mounting Kit, allows 4010-9928 selecting two,dual Vertical Block(flat)modules 2 Vertical Blocks NA NA from the list below Modular Network Interface Card 4010-9922 (requires two media modules,see below) 2 Vertical Blocks 30 mA 30 mA 4010-9818 Network Media Card Wired N�q 55 mA 55 mA 4010-9819 Network Media Card Fiber Optic (mounts to 4010-9922) 25 mA 25 mA 4010-9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA 4010-9923` SafeLINC Internet Interface 2 Vertical Blocks 115 mA 115 mA 4010-9924� Modem Physical Bridge Class B(Style 4) Requires one of the 2 193 mA 193 mA Vertical Block spaces on the 4010-9925* Modem Physical Bridge Class X(Style 7) 4010-9928 Mounting Kit 246 mA 246 mA 4010-9926'" TCP/IP Physical Bridge Class B(Style 4) 3 Block"L"Shape, requires 196 mA 196 mA one of the 2 Vertical Block 4010-9927�` TCP/IP Physical Bridge Class X(Style 7) spaces on the 4010-9928 236 mA 236 mA Mounting Kit, plus Block D Dual Vertical Block(Slot) Modules, Select One if no Dual Vertical (Flat) Modules from Above are Selected Model Features Option Block Usage Supervisory Alarm Current Current 4010-9920 8 Zone Initiating Device Circuit-Class B 2 Vertical Blocks mother/dau hter card 75 mA 195 mA 4010-9921 8 Zone Initiating Device Circuit-Class A � 9 ) 'UL, ULC,and CSFM listed. `�FM Approved only. 6 S4010-0004-7 1/2013 � • • • • • • • • • • . • - • Model Features Supervisory Alarm Mounting Requirements Current Current 4010-9909 City Connect Module w/disconnect switches 20 mA 36 mA 4010-9910 City Connect Module 20 mA 36 mA Select one maximum, mounts on Main System Supply 4010-9911 Alarm Relay Module 15 mA 37 mA 4190-6104� Truelnsight Remote Gateway 62 mA 62 mA Mounts on Front Door 4100-5128 Battery Distribution Terminal Block, mounts to side of box, required when battery connection leaves the 4010ES box(also used in the 4100ES fire alarm control panel) *Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details. • � . Front view,cabinet outline without door Side view with door attached 16"(406 mm) Total depth, —--— Box depth, box and door 6-29/32" 11-11/16" (296 mm) ' (175 mm) Exposed cabinet for Use 4 holes to semi-flush mounting Secure box to wall 1-3/8"(35 mm)minimum 22" (559 mm) Stud alignment Exposed door and cabinet markers, each side for semi-flush mounting 6-1/8"(156 mm)minimum 6"stud ,-----------------------------------� Door thickness 4"stud o Reserved for Batteries o 4-3/4"(121 mm) �--- ---��_ 24"(610 mm) . � . LED Kits Model Description 4100-9843 8 Yellow LED Kit 4100-9844 8 Green LED Kit 4100-9845 8 Red LED Kit 4100-9855 8 Blue LED Kit End User Programming Tools Model Description 4100-8802 End User Programming Unit Software 4100-0292 Custom Label Editing (USB Dongle) 4100-0295 Port Vectoring Setup and Control (USB Dongle) 4100-0296 User Group/Passcode Editing(USB Dongle) 4100-0298 WalkTest Configuration Setup and Control(USB Dongle) 4010ES Factory Programming Model Description 4010-8810 4010ES Factory Programming 4010-0831 Custom Label and Panel Programming 7 S4010-0004-7 1/2013 � 1 1 • ` • • � • • The 4010ES has a maximum Internal and External Card Address Limit of 20 Card Addresses.Use the Table below to calculate 4010ES card address allocation. INSTRUCTIONS: Below is a list of 4010ES equipment and the quantity of card addresses they consume 1. For the applicable control panel,write in the Card Address Consumption value in the Card Address Allocation column. (Note:Only select 1 control panel) 2. For the option cards to be installed on the 4010ES,write in the Card Address Consumption value in the Card Address Allocation column. 3.Total the Card Address Allocation column(total must not exceed 20). Model Description Card Address Card Address Notes Consumption Allocation Control Panels(Select One) 4010-9401 2x40 Display,Single IDNet Channel,Single Bay Box 2 4010-9402 4010-9403 4010-9404 4010-9405& 4010-9405 2x40 Display,Single IDNet Channel,48 Pluggable LED Module 3 4010-9406 are for 4010-9406 Canada Panel Option Cards(Select As Required) 4010-9901 Flat VESDA HLI Card 1 4010-9922 Flat Network Card 1 4010-9908 4 Point Flat Aux Relay Module 1 4010-9912 Serial DACT 1 4010-9923 SafeLINC Internet Interface Card 1 4010-9914 Building Network Interface Card 1 4010-9918 Dual RS-232 Module 1 4010-9920 8 Zone Initiating Device Circuit-Class B 1 4010-9921 8 Zone Initiating Device Circuit-Class A 1 Remote Power/Notification(Select As Required) 4009-9401 TrueAlert Addressable Controller(4009T)120 VAC 1 4009-9402CA TrueAlert Addressable Controller(4009T)w/Low Battery Cutout 1 for Canada 4009-9813 Transponder Interface Card for 4009 TPS 1 4100-5120 120 VAC Domestic TrueAlert Power Supply for 4009 TPS 1 4100-5121 120 VAC Canadian TrueAlert Power Supply for 4009 TPS 1 for Canada Remote Annunciation(Select As Required) 4100-9401 Red Cabinet, English 2 4100-9403 Remote Platinum Cabinet, English 2 4100-9421 InfoAlarm Red Cabinet, French 2 for Canada 4100-9423 Command Platinum Cabinet, French 2 for Canada 4100-9441 Center Red Cabinet,with blank inserts for key labels 2 4100-9443 Platinum Cabinet,with blank inserts for key labels 2 4606-9102 4010ES RUI LCD Annunciator, English 1 4606-9102BA 4010ES RUI LCD Annunciator,English 1 4606-9102CF 4010ES RUI LCD Annunciator, French 1 for Canada 4602-9101 Status Command Unit(SCU)LED Annunciator 1 4602-9102 Remote Command Unit(RCU)LED Annunciator w/control 1 4602-9150 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1 4602-7101 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1 4602-7001 RCU for cabinet mount 1 4602-6001 SCU for cabinet mount 1 4100-7401 24 Point I/O Graphic Module for custom annunciator panels 1 4100-7402 64/64 LED Switch Controller for custom annunciator panels 1 4100-7403 32 Point LED Driver Module for custom annunciator panels 1 4100-7404 32 Point Switch Input Module for custom annunciator panels 1 Total Card Addresses(Not to Exceed 20) TOTAL 8 S4010-0004-7 1/2013 . . AC Input Current 4 A maximum, 120 VAC @ 60 Hz nominal Including module currents and auxiliary power Output switches to Power Supply Output Total Power Supply outputs; 8 A total for"Special Application" battery backup Ratings(nominal 28 VDC Output Rating appliances;4 A total for"Regulated 24 DC"power during mains AC on AC,24 VDC on (see below for details) failure or brownout battery backup) conditions Auxiliary Power Tap 2 A maximum, rated 19.1 to 31.1 VDC Special Application Simplex 4901,4903,4904,and 4906 Series horns, strobes, and combination horn/strobes and Appliances, maximum of speaker/strobes(contact your Simplex product representative for compatible appliances) 70 appliances per NAC Regulated 24 DC Power for other UL listed appliances; use associated external synchronization modules where Appliances required UL listed for battery charging of 6.2 Ah up to 110 Ah; ULC listed for Battery capacity range charging up to 50 Ah batteries; batteries above 33 Ah require separate Battery Charger Rating cabinet (sealed lead acid batteries) Charger characteristics Temperature compensated,dual rate, recharges depleted batteries within and performance 48 hours per UL Standard 864;to 70%capacity in 12 hours per ULC Standard S527 Operating Temperature 32°to 120°F(0°to 49°C) Environmental Operating Humidity Up to 93°/o RH, non-condensing @ 90° F(32°C)maximum Additional Technical Installation Instructions 579-989 Reference Operating Instructions 579-969 � • • . . . . • . . • Subject Data Sheet Subject Data Sheet 4010ES Agent Release Applications and S4010-0005 Network Communications S4100-0056 Accessories Agent Release Accessories S2080-0010 Multi-Signal Fiber Optics S4100-0049 Building Network Interface S4100-0061 4602 Series SCU/RCU S4602-0001 SafeLINC Internet Interface S4100-0062 PC Annunciator S4190-0013 Interface to VESDA Air Aspiration Detection S4100-0026 TrueAlert Addressable Controller(4009T) S4009-0003 Systems Serial DACT(SDACT) S2080-0009 4009 IDNet NAC Extender S4009-0002 Fire Alarm Network Overview S4100-0055 4003EC Voice Control Panel S4003-0002 Truelnsight Remote Service S4100-0063 120 VAC Desktop Remote Printer S4190-0011 Addressable Device Compatibility, IDNet 4009 TPS(Remote TrueAlert Power Supply) Communication Sensors and Devices S4090-0011 Reference S4100-0037 4606-9102 Remote LCD Annunciator S4606-0002 110 Ah Batteries and Cabinets S2081-0012 Graphic I/O Modules S4100-0005 Remote 110 Ah Battery Chargers and Cabinets S4081-0002 Remote InfoAlarm Command Center S4010-0008 BACpac Ethernet Portal Module S4100-0051 PC Annunciator S4190-0013 Network Physical Bridge S4100-0057 TCP/IP Physical Bridge S4100-0029 9 S4010-0004-7 1/2013 TYCO,SIMPLEX,and the product names listed ni this material are marks and/or registered marks.Uriauthor�ized use is str�ictly prohibited.VFSDA is a trademark ofXtralis Pty Ltd.NFPA 72 and National Fire Alarm and Signaling Code m�e trademarks of�the National Fire Protectlon Assoclatron(NFPA).ASHRAE and BACnet are Krademarks of ASHRAE,American Society of Heating,Refrigeration,and Air Conditioning F_ngineers. �05 i m p I Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4010-0004-7 1/2013 www.simplexgrinnell.com O 2013 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are su6ject to change without notice. �oSimplEx Fire Control Panel Accessories UL, ULC, CSFM Listed� Truelnsight Remote Service Overview and Hardware Reference � Remote Truelnsight Remote Real time data gathering and diagnostics for fire Technician's Service Center alarm control panel systems: Computer • An internally mounted interface module securely connects f –� � Local the panel computer port protocol interface to an Ethernet Technician's connection allowing information about trouble(or Computer ���� potential trouble)conditions to be sent to the Remote ��°� �-� �! Service Center via an Internet connection Technician's � �--��� • At the Remote Service Center,receipt of trouble Computer Firewall i information triggers an email to an experienced technician -� ,��I����� ; , who reviews the informarion and can further query the � ;+�=!�� panel for more information as the condition is invesrigated; (NOTE:Alarm information is only logged by this service; �"��� �-'� I' I Alarin information must be sent separately to the ` �--� designated monitoring/response location.) � • Technicians can connect to the panel from a remote Service Center Firewall location via secured internet communications and interrogate the system status • After details of the panel status are analyzed,tbe service personnel dispatched to the site can be selected for their specific experience and equipped with the needed Internet Connection replacement parts and tools before visiting the site • Truelnsight Remote Service logs panel activity(troubles and alarms)and maintains it for one year allowing detailed activity historical review or forensic review if required Customer Firewall Application Details: r -- --- • For use with Simplex°4100ES,4010ES, and 4100U Fire = �a Alarm Control panels � 4100ES Panel • Module connects without need for panel programming with 4190-6104 S@CUP@ COI'T1111UflIC8t1o11S: � � I ; o- Truelnsight • Control panel interface module is connected behind / ����� module customer's firewall mimimimi�iwiwi�imimimimioiu�uui�u� mimimimi�imimiwimimimimmimm�im� • Receiving equipment resides under the Remote Service _ _____ Center firewall or under the individual technician's — — computer firewall Truelnsight Remote Services Reference Diagram • Customer to provide network access/connectivity (4100ES shown for reference) Additional Information: • Contact your local Simplex product representative for • • - • • • • specific details on how to connect your panel to TrueInsight Remote Services Modules and remote devices of a fire alarm control panel are interconnected with internal wiring harnesses and with � � � external wiring. Over time,or even during initial installation,those connections may become loose or Connecting to Control Panel Intelligence.4100ES, otherwise compromised. Due to module and wiring 4010ES,and 4100U addressable fire alarm control panels supervision,these trouble conditions are discovered and provide intelligent monitoring of internal modules, incoming their locations are identified by the panel. power,battery connections,and of connected remote devices (continued nextpage) and appliances such as TrueAlarm analog sensors,TrueAlert addressablenotification,devicescontrolledb IDNet ` T�"s���"�'���'tr,ec,��f«„�ast�eFrerv��sna��csFm�p�,�,tto �' Section 13144.1 of the Califania H�Ith and SaFety Code.See CSFM Listings communications,and the connected wiring. TrueInsight 71G�r0026:0251 and7165-00'16:Q369for�laval�evaluesand/orconditior�so�r�erning Remote Service monitors this information and takes action ���Pr��intFtisdocurrent.ltissubjecttoree�rririation,re�s�a,,and posside cance�lation.This produd was not FM apFxoved or accepted by the NYC FD� when trouble conditions arereported. o�docu�re�;s�o„date.adda�a,a�us���s�reyneapp�ca�e;ca,�aayouri«� Sirrplex product supplier fa the latest status.Listings and approvals under Sirrpleac Tme Reoorder Co.are the property of Tyco Fre Protection Prock�s. S4100-0063-3 3/2013 • • ' • • • • 1 'I Devices and their wiring are subject to motion. TrueAlarm Sensor Monitoring (Continued). Mechanical wiring disturbances can be due to a variety of Should a difficult environment experience nuisance subtle or significant activity such as earthquakes(even alarms,this diagnosric tool can be accessed remotely as a seemingly minor earthquakes may shake buildings more means of analyzing the stability of the sensor's than expected),farklift activiry coming closer than environment. This allows the sensor sensitivity to be planned, large fire doors or outside shipping dock doors properly selected for its actual environment ensuring slamming shut closer to fire alarm devices tban realized, optimal response time and protecrion from nuisance alarm and other human intervention can unintentionally cause sources. fire alarm wiring connections to becon�e loose or broken. gatteries wear out.Fire alarm control panels typically When the panel discovers this type of condition,it rely upon internally mounted,or perhaps remotely declares a trouble,the circuit and specific condition is mounted batteries with battery chargers to provide power logged and identified with a local sound and flashing during local AC mains failure. Rechargeable batteries are yellow light,however the exact details are not normally complex chemical/mechanical/electrical designs and after available other than by querying the individual panel for repeated charge and discharge cycles,will begin to lose more information on-site.Accessing this information total capacity. By monitoring battery capacity at the remotely allows TrueInsight Remote Service personnel to panel,battery condition can be tracked,but to better determine the source of the trouble including which understand battery charging status,detailed charger devices by specific model number may be involved. operation needs to be queried.Using TrueInsight Remote Smoke sensors get dirty. TrueAlarm smoke sensors Service allows that extra information to be investigated to are open to the environment in arder to sample for the diagnose specific panel conditions and then to determine presence of smoke particles.This also allows a collection whether it is time to replace batteries,inspect battery of dirt ar other debris, sometimes a lot of it,and in a short connections,or to test the battery charger,allowing the period of time. TrueAlarm technology compensates very anticipated equipment to be available at the time of a well up to the point where a device is identified as dirty service call. and needs to be inspected and cleaned.Knowing that a Monitoring includes communicating devices and sensor is in need of service before it actually gets out of devices they monitor.With IDNet communicarions, compensation allows a system to provide essentially these panels monitor and control a wide variety of uninterrupted service. remotely connected devices.If communications fail to TrueAlarm Sensor Monitoring. TrueAlarm smoke properly operate,the device(s)not communicating are sensing tracks the Peak Analog Value associated with identified.If the devices are in turn monitoring each sensor's environment. connections local to their location,such as relay coils, conventional IDCs or NACs,problems with those connections are communicated back to the control panel. . . . Model Description Ordering Information 4190-8001 Truelnsight Remote Service Module and Programming Selection Truelnsight Remote Service Module Installation Kit; includes Required Selection 4190-6104 module, required mounting brackets and harnesses for either the 4100ES,4010ES, or 4100U 4190-4016 Truelnsight Remote Service Module for fixed IP Addressing Optional, select if application will be using a fixed IP address � 1 1 . ���IIII��������II���������I�I��������IID�I�����II�D��II�����������DDD�DD��������I I�����0�0�0000_�00���0�I��O� 0 ����������������o�ii������������������������������oo���o������i���������������������o�����a�������������o�a���ea� ��� � �� ���o� � ao' �� � °I 0 � `� . � � � � � 'o n�:::::a� _ ,� o 0 � ' 0 � �� o o ��� ° � Truelnsight Module � o o � o❑o a � � a mounts here on rear of � 4010ES front panel l rl fl � ffl r l �jfffff f � � ���II��II��I�����III��III I��IIIII����II II�IIII�.���IIII�II�IIII I�II��I����II I�IIII���II�III����III�����.����IIII II�II���.IIIIIIIII����IIII II��II�I�I��III I�II�IIIII� ° a �����I���������I����I�I��III���I��I II���������I IIII��II��I����I II��I������I�I���II������II��������II��I�II�I������I���������I��I���������I�I�� a a 2 S4100-0063-3 3/2013 . . . - Determine Connection Location Type: 1. Panel Location requiring internal connection.If the panel is located in a lobby or other public area,or is semi-flush with the box essentially fully mounted -- - - - - - - in the wall,an interna]connection is recommended, and most likely required. 2. Panel Location allowing external connection.If the i �-o�� � ' panel is in a utility ar telecom closet,or other sio�z'� I°� controlled access location,and is surface mounted Master with the box fully exposed, an external jack Contro��er eay=�' connection is acceptable if desired. , - Wiring Alternatives: � 1. Internal Connections.Run Ethernet cable through existing conduit if the conduit is not beyond capacity ,o, POWeI" �Ill'lltGd (as defined per local codes and standards)and ='�" _'�„ "�„ ` contains only power-limited signal wiring.Ethernet ` Wlring area cable should not be run in the same conduit as AC -� ° -�� � power as this will interfere with signal integriry and it pp, z�,, s�� .,��y� � ,, � may not meet local code. Terminate the cable with an � III ,e�o�,�,„ RJ-45 Male connector or install an RJ-45 Female °;'ok°Fl � jack(preferred).Attach the female jack to the internal � -, � � sides of the back box,in the power-limited area of the ! ' � cabinet(see illustrarion to the right). Use an adhesive style mount and follow the manufacturer's instructions such as to use a cleaning solvent like =��„ _��,_ _��,_ =��,a =��,s =��,e =��„ =��,a alcohol on the box surface before you mount it. � � ��•�M ��-��ro s ����s ,�Mad��r 2. External Connections.If the Ethernet cable cannot ' � `� �a���E� be run into the cabinet directly, locate the termination ��� Expan�sion Bay z�`"°;�ps; within 6 ft(1.8 m)of the panel,on the power limited = I � „a og, sides,and preferably terminated with an RJ-45 °���b°F;` Female jack If you have local IT requirements for _, � _ �����s. _-- � specific color wire,provide the desired color patch I cable to extend from the jack to the panel. To allow I for internal wiring requirements,the patch cable length needs to be 8 to 10 ft(2.4 m to 3 m)longer Battery Compartment than the distance from the jack to the panel. (If the connection is to be provided as a cable terminated with a RJ-45 Male connector instead of a Female jack,the distance requirement remains,adequate cable for a clean connection to the panel plus 8 to 10 Three-Bay 4100ES Showing Power Limited ft additional for internal cable routing.) Wiring Area (in dark gray) Panel Access Precautions: 1. If you do not have conduit available or are unsure about where to route the cable,do not drill into the panel box. Leave a spool of cable in the ceiling or the vicinity of the panel (long enough to be routed into the panel)and coordinate with your Simplex technical representative as to how to proceed. Acceptable Cable Types: 1. Use EIA/TIA-568a CAT-S-Compliant Cable or better. 2. Either Unshielded(UTP)or Shielded(STP)Cable is Acceptable. 3 S4100-0063-3 3/2013 . . . . - . Module 4100ES or 4100U Left side of expansion bay bracket, preferred location is bay 2 NOTE: Module locations do mounting 4010ES On back side of dress panel not require bay space Voltage 24 VDC,system supplied 62 mA in standby Current 73 mA maximum when active Environmental 10 to 93% RH from 32°to 120°F(0°to 49°C) System Power; RS-232 Communications Port to panel; Ethernet RJ45 connection Connection Requirements NOTE:When possible,terminate the Ethernet drop in the panel enclosure. If not possible, and the panel is in a secure area, locate an external drop within 6 ft(1.8 m)of the panel enclosure. Power/Ready: Steady Green=system ready; Flashing Green or Flashing Yellow=system is booting up(details are described in Installation Instructions); Red=Error condition Link/10/100: Green= 10 Mbit connection;Yellow= 100 Mbit connection; Dark=no connection Module LED Diagnostics(5 LEDs) Activity: Steady Green=heavy traffic; Flashing Green=some traffic; Dark=no traffic, possibly no connection Transmit(Tx): Flashing or Steady Green=sending data Receiver(Rx): Flashing or Steady Green=receiving data Installation Instructions 579-953 Panel Data Sheet 4100ES S4100-0031 Reference 4010ES S4010-0004 11 11 • a ��0 ° � �.�.. o o r�°` � °� ° ��"a o � � Q o � o � o p � Y`< � ° o o a o � o � 0 0 0 p 0� O 9��e�s+ � 0 � � ����ae� . pe�e��� �y e � Be R% .�� � `�� � , ;�"'�� I � �` e j �e�Q�e� . Truelnsight Module on mounting � � ���,� `��ee �p � � plate mounts on left side of o `'�e�ape�e o 4100ES/4100U bay bracket � o 0 Q � o� � o � o � � o� ��0 o � --Q- �� � � � � e o ��� \ � � � 0 � �0� TYCQ SIMPLEX,and the product names listed in this materzal are marks and/or registered marks.Unauthorized use is strictly prohibited. �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4100-0063-3 3/2013 www.simplexgrinnell.com OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger � J --- Rechargeable, sealed lead-acid batteries: -- -- • Lead-calcium grid structure with immobilized _ electrolyte in absorbent separator �0000 _ „� o�ooa • Low maintenance with no need to add water • Low self-discharge characteristics • One-piece,high impact polystyrene cell cover with high reliabiliry dua] seal construction • UL 924 recognized pressure relief valves � ;@�• Available in a variety of capacities: • Batteries for internal mounring range from 6.2 Ah up to � 50 Ah,depending on control panel cabinet size • Larger batteries, up to ll 0 Ah,mount in external battery cabinets with models available with internal chargers Battery cabinets with chargers: • Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/4010ES/4100U Series and 4010 Series panels __ _ � _ � . Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Simplex°rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems � applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction,packaging is allowed within the system electronics enclosure(see illustration on page 2).When this is applicable,the quantity of system cabinets and the battery wiring distances are both minimized.Where required,external battery cabinets can Remote Battery Cabinets are Available for be close-nippled to the control panel to house larger Larger Battery Requirements batteries with battery chargers available in some battery cabinet sizes. � � • -� Charging. These batteries are intended to be used with Shipping. Sealed lead-acid batteries are shipped via compatible Simplex battery chargers. ground or sea transportation only. They are not shipped via air. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Disposal. Battery chemicals and materials can be Battery sets must be of idenrical voltage,model number, recycled. Refer to information shipped with the battery or appearance,and approximately the same date of on its case.Return to the battery manufacturer or to a manufacture for proper operaYion. similarly qualified battery processing facility for proper disposal. Testing.Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester � �{�-to details on page 4 and to the referer�ced individual product data designed to withdraw a minimum of battery charge. The sheets fa-ageaicy�isting status of battery cabinets and ct,argers.TI-ie batteries preferred tester applies a variety of amplitude and detailed in this cloa.iment rreet the requirerrents of UL,ULC,and Fac#ay duration controlled test pulses that compares terminal Mutual for use with respective equipment battery chargers as listed on page 3. voltage against those predicted for the specific battery �tad Your local Sirrplex product supp�ier fa-proper battery seledia,per size. (Testing is available through your local Simplex systemrequire���ts.ListingsandapprovalsunderSirrplexTimeReca-der product supplier.) Co.are the prc�erly of Tyco Fre Protedion Produds. S2081-0006-20 1/2012 . . Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size)� Potting material,black for negative,red for positive 0 0 (polarity is also clearly � marked with+and-) � Pressure relief valve Innercover Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids membrane separator Cell group Cell case(high impact polystyrene) • • Capacity @ 20 Hour Height with Approximate Battery Model Discharge Rate Width" Depth" Terminals Weight* 2081-9272 6.2 Ah 6-1/8"(156 mm) 2-5/8"(67 mm) 4"(102 mm) 5.75 Ibs(2.6 kg) 2081-9274 10 Ah 6"(153 mm) 4-1/16"(103 mm) 4"(102 mm) 9.2 Ibs(4.2 kg) 2081-9288 12.7 Ah 6"(153 mm) 4"(102 mm) 4"(102 mm) 9 Ibs(4.1 kg) 2081-9275 18 Ah 7-1/4"(184 mm) 3-3/8"(86 mm) 6-5/8"(168 mm) 14.3 Ibs(6.5 kg) 2081-9287 25 Ah 6-5/8"(168 mm) 5"(127 mm) 7"(178 mm) 19.4 Ibs(8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2"(318 mm) 3-3/8"(86 mm) 7-1/16"(179 mm) 26.6 Ibs(12.1 kg) typically for service) 2081-9276 ("square"case, 33 Ah 7-3/4"(197 mm) 5-1/4"(133 mm) 6-3/4"(171 mm) 26.5 Ibs(12 kg) use for new) 2081-9296 50 Ah 9"(229 mm) 5-1/2"(140 mm) 8-7/8"(225 mm) 41.8 Ibs(19 kg) 2081-9279 110 Ah 11-3/16"(284 mm) 10-1/2"(267 mm) 9"(230 mm) 82 Lbs(37 kg) � Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility.These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output,these batteries are to be of identical voltage,appearance,model number,and approximately the same date of manufacture. • • Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F(15.6°C to 32.2°C) 2 S2081-0006-20 1/2012 . . . . . � . . . . NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series(see legend and notes below) Battery Capacity Model 4006& 4009 4100ES/ 4100&4120 4020 4003EC 4004R 4005 4008 (all models) 4010 4010ES 4100U (2,4 or 6-Unit) (2,4 or 6-Unit) 2081-9272 6.2 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2081-9274 10 Ah �/ ./ �/ �/ �/ ./ �/ �/ �/ ./ 2081-9288 12.7 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2081-9275 18 Ah Ext Note 3 J Ext Ext Note 2 �/ �/ ./ ,/ 2081-9287 25 Ah Ext Note 3 Ext Ext NA ✓ ✓ ✓ ✓ Ext 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 �/ �/ Ext Note 4 rectangular 2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 ✓ ✓ ✓ Ext "square" 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext Ext 2081-9279 110 Ah Requires external battery cabinet,compatible with 4100ES,4010ES,4100,and 4120 Series only ✓ =Can be placed in the respective equipment cabinet Ext=External battery cabinet is required, refer to selection chart on page 4 NA=Not applicable/not compatible NOTES: 1. These batteries meet the requirements of UL, ULC,and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger, refer to page 4. 4. 4020 Cabinets will accommodate 2081-9271,33 Ah batteries, but will not allow bottom entry conduit. 5. Some control panel models are listed for battery replacement reference only. 6. For 2 bay international applications only,50 Ah batteries will fit in the cabinet. . . . • . • Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 2081-9280 4100ES,4010ES, NA NA NA NA NA ✓ 4100U, and 4100+ 2081-9281 multiple �/ �/ ✓ J ✓ NA 2081-9282 4009-9801 multiple ✓ ✓"* NA NA NA NA 4009-9802 multiple ✓ NA ✓ NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 J ./ ✓ J J NA 4081-9302 4081-9306 4100ES,4010ES, NA NA NA NA �/ J 4081-9308 and 4100U *Batteries smaller than those listed are normally mounted in the product cabinet "25 Ah capacity was effective as of 7/2005. ✓=Can be placed in the respective equipment cabinet NA=Not applicable/not compatible 3 S2081-0006-20 1/2012 . . . Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and 2'Unit,4100 style cabinet without charger;with locking 25-3/4"W x 20-3/4"H x 6-3/4"D FM solid door and battery shelf, primarily for use with 50 Ah (654 mm x 527 mm x 171 mm) 2081-9282 Red batteries 4003-9860 Beige Multiple Intended for use with 4003EC systems,for up to 33 Ah 9-1/2"H x 24"W x 9"D batteries(refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 4009-9801' Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4"W x 13-1/2"H x 5-3/4"D FM batteries' with locking solid door and battery (413 mm x 343 mm x 146 mm)* For up to 33 Ah harness;for close-nippled mounting to 25-3/4"W x 20-3/4"H x 4-1/8"D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) *Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions 4081-9301 Beige Battery cabinet with charger for the 4010 and 4004R fire alarm control panel;for up to 50 Ah 120 VAC batteries;with front door 22-1/2"W x16-3/4"H x 8-3/8"D 4081-9302 Red Listings include:UL, ULC, FM, CSFM, and MEA �572 mm x 425 mm x 213 mm) (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model& Color Cabinet Description Compatible Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100ES/4100U System Power Series Supplies(SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100ES/4100U Additional SPS 2081-9280 batteries; includes 4100-5113 Listings Red $0 A battery fuse, 4100-5125 4100ES/4100U Remote Power 26-1/2"W x 12"H x 12"D include:UL terminals and 4100-5126 Supply(RPS) (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 cables; see data 4100-5120 sheet for details 4100-5121 4100ES/4100U TrueAlert 4100-5122 Addressable Power Supply(TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4100ES/4010ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; referto data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8"W x 13-1/2"H x 14-5/8"D 220/230/240 VAC, 110 Ah batteries;Listings include:UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red multi-tapped CSFM, and MEA (NYC), see data sheet for details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing,mounts above access panel using knockout provided TYCO,SIMPLEX,and zhe product names Iisted in this material are marks and/a��-egistered marks.Unauthorized use is strictly pi�ohibited. �oSim plEx Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S2081-0006-20 1/2012 www.simplexgrinnell.com OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx System Accessories, LCD Annunciators UL, ULC, CSFM Listed; 4606-9102 LCD Annunciator FM, NYC Fire DeptApproved* for 4010ES Fire Alarm Control Panels � Remote LCD annunciator for use with Simplex° model 4010ES fiire alarm control panels � � LCD readout provides: =��TEM I`N�R�,� !��:25:15 an�THU 02-AUG-1� • Two lines of 40 characters each • Wide viewing angle,super-twist design `#'�' • LED backlighting � � sss�mp� Control switches and status LEDs for: • Alarm,Priority 2, Supervisory,or Trouble 4606-9102 LCD Annunciator acknowledge(keyswitch access controlled) • Alarm silence, System reset � � � � _� • Three programmable control switches with yellow LEDs and provisions for custom labeling Indications. Alarm, Prioriry 2, Supervisory,and Trouble Additional features: condirions are also indicated by dedicated LEDs and a • Information is transmitted over a single unshielded tione-alert audible indication.Each condition has a dedicated acknowledge push-button switch that silences twisted pair; separate wiring is required for 24 VDC the tone-alert but leaves the LED on until all conditions in control panel power(see p. 3 for more information) that category are restored to normal. • Tone-alert sounder provides local audible indication Lamp and LCD are functionally tested each time the ACtivity Scrolling. Repeated operation of the � keyswitch is turned on appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. • Mounts flush on standard 6-gang electrical box The internal tone-alert also sounds to indicate the • Up to up to 20 internal and external card addresses per operation of any of the push-button switches. 4010ES fire alarm control panel Mounting and trim options (ordered separately, � ' ' ' see page 3 for more details): Keyswitch Access.All switches on the annunciator are • Surface mount box mode12975-9206 controlled by the"ENABLE"lceyswitch with a key that is • Brushed stainless steel trim model 4603-9111 removable only in the disabled position.A brief Lamp/LCD test is performed whenever the keyswitch is � - . . changed from enabled to disabled. Enabled Operations. When enabled,notification Local Annunciation.4606-9102 LCD Annunciator appliances can be deactivated by pressing the"ALARM allows 4010ES fire alarm control panels to provide SILENCE"switch.Pressing the"SYSTEM RESET" information and control switches at convenient locations switch restores the system to normal operation.When away from the control paneL The LCD is an 80 character, system activity is normal,the LCD displays the time, back-lit,alphanumeric display with information presented date, and"SYSTEM IS NORMAL." in clear and descriptive English. Typical content includes: point status(alarm,trouble,etc.),alarm type(smoke detector,manual station,etc.),number of system alarms, supervisory conditions,troubles, and custom location labels up to 40 characters long. * This product has been approved by the Califomia State Fre N�rshal(CSFN�pursuai�t to �.011llllU111CatIO11S. D1t1 COri1ri1Uri1CahOriS T'eC1Ult'0 a Sediq�13144.1oftheCalifomiaHealtharidSaFetyCode.SeeCSFMListing single unshielded twisted pair that supports other 73040026.0370faallavablevaluesarxl�orcondiUonsoaxemingrratenal preserrtedin annunciators on the same communications channel. tr�s doa�r,�r,t.it�5 s�,t��to r��r�;r,at�«,,r��or,,arid pcssible canodlation.NYC Fre Dept CCW#160�.Additia�al listirx�s rr�y be applicable;contact your local Sirrpleac product supplier for the latest status.Listings and apprwals urxier Sirrplex Tirre Recorder Co.are the prope�ty of Tyoo Fre Protedion Products. S4606-0002-5 8/2012 . . . Model Description 4606-9102 Remote LCD Annunciator with beige trim for use with 4010ES fire alarm control panels Refer to specifications on page 3 4603-9111 Brushed stainless steel trim option for additional details 2975-9206 Matching surface mount box; ivory finish 2081-9044 Overvoltage protector; required where annunciator communications and power wiring exits and enters a building; refer to data sheet S2081-0016 for details � . 1 . • 1 • • - . • . . 2 X 40 LCD READOUT,green LED backlighted during normal conditions and abnormal operating conditions SIX STATUS INDICATOR LEDs provide system status indications in addition to LCD information;LEDs flash to indicate the condition and then when acknowledged, THREE PROGRAMMABLE(Yellow) remain on steady until reset; Fire Alarm and Priority 2 LEDs,each with pushbutton switch and Alarm are red;System Supervisory,System Trouble, custom labeling pocket and Alarm Silenced are yellow;Power On is green � �;Ja DISPLAY TIME '��Y'��TEt�! I'=� I�I��RC�I{�L displays time of last ; �°'�� ;. rr € 3f 1- �•EIEi �,'�; occurrenceofevent 1z'_r'::'_•_�z 1:_ � i-€_ �.�'-.,�_�_- ; list being displayed; � or displays current � time when viewing � - system status � � � , ,���; ` information � � `� f3 Sim lex ALARM ACK/FIRE ALARM acknowledges a Fire Alarm condition and silences the SYSTEM RESET restores panel and all annunciator ton�alerts control panel to normal CONTROL ENABLE when all alarmed inputs ALARM ACK/PRIORITY 2 acknowiedges KEYSWITCH are returned to normal a Priority 2 Alarm condition and silences controls all switch functions; the panel and all annunciator tone-alerts key is removable only in disabled position SUPV ACK acknowledges System Supervisory conditions and silences the ALARM SILENCE causes audible panel and all annunciator tone-alerts notification appliances to be silenced; used after evacuation is complete and TROUBLE ACK acknowledges while alarm source is being investigated System Troubles and silences the panel and all annunciator tone-alerts 2 S4606-0002-5 8/2012 � . 1 . • 1 � � . • • - • General Operating Specifications (refer to Installation Instructions 579-977 for additional information) Voltage 18 to 32 VDC, system supplied Normal Operating Current 110 mA(with LED backlighting on) Battery Standby Current 65 mA(during battery backup, LED backlighting is turned off after 30 seconds without switch activity) Alarm Current 140 mA maximum (LED backlighting is on and tone-alert is sounding) Operating Temperature Range 32°to 120° F (0°to 49° C) Operating Humidity Range Up to 93% RH, non-condensing at 100° F(38° C) Communications RUI (Remote Unit Interface)external annunciator communications line SLC For 4010ES Panels* Type (signaling line circuit) Capacity Up to 20 total internal and external card addresses Wiring Requirements Standard Wiring Type Unshielded twisted pair(UTP), 18 AWG (0.82 mm2)for most applications, see below Wiring Characteristics 0.58 uF (580 nF) maximum capacitance between conductors; 35 S2 maximum total line resistance 1. Wiring that leaves the building.Also requires Isolated Loop Circuit Protectors on each end, refer to data sheet S2081-0007 for 2081-9027 (200 mA), or Wiring Applications S2081-0008 for 2081-9028(5 A) RUI Data Requiring Shielded, 2. Wiring run in 500 ft(152 m)or more of conduit. Twisted Pair(STP) 3. Wiring closely bundled with standard IDNet communications or TrueAlert addressable communications (not required when run with IDNet+ communications). Class B"T-Tap"wiring Up to 10,000 ft(3048 m)total wiring; up to 2500 ft(762 m)to farthest device distance Class X wiring distance Up to 2500 ft(762 m) Power Wiring 18 to 12 AWG (0.82 mmZ to 3.31 mmZ)wires for 24 VDC system power A dedicated earth ground connection to the electrical box is required for proper ESD Earth Wiring and EMI protection; wire in accordance with NFPA 70 (National Electrical Code) Article 250 Mounting Information Trim Dimensions 4'h" H x 11 13��6"W(114 mm x 300 mm) Assembly Depth � 5�6 (33 mm), 1 '/2"at terminal block location (38 mm) Standard Trim Finish Steel, painted beige 4603-9111, Optional Trim Brushed stainless steel (ordered separately); supplied with both slotted and tamper resistant screws Boxes for Masonry boxes Six-gang box, RACO#965, 3'/z' (89 mm)deep or equal Mounting Single gang boxes Six, single gang boxes, 3'/2'(89 mm)deep minimum, RACO#590 or equal (supplied Conduit entrance is box dependent, refer to Installation Instructions 579-977 for separately) Box selection note additional mounting information and conduit entry requirements 2975-9206, Surface Mount Box Option (ordered separately) Dimensions 12"W x 4 5/8" H x 2 3/4" D (305 mm x 117 mm x 70 mm) Finish Painted steel, ivory finish * Refer to the 4010ES control panel data sheet for additional panel information. 3 S4606-0002-5 8/2012 . . . . Note: Review box choice with assembly layout before selecting conduit entrance location to allow easy access to terminals Flush Mount Ganged Boxes: Requires 6-gang box, 3-1/2" (89 mm) min. depth, use (6) RACO#590 or equal ° o° ° o° ° o-° ° o° ° o° ° o° (supplied separately) Flush Mount Masonry Box: � Use RACO#965, 3-1/2" (89 mm) deep or equal (supplied separately) ° ° ° �-� �� �� 0 0 o a o o � Surface Mount Box: � , Simplex model 2975-9206 2-3/4"deep(70 mm) 0 (ordered separately) o 0 0 0 0 0 O o o O LCD Annunciator Assembly—. Trim plate • v �� Terminal block O o 0 access at rear of assembly, this side O O Q�m�ex • Interconnection Wiring Notes: 1. Communications require 18 to 12 AWG unshielded twisted pair. 2. Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus Earth Ground to each electrical box. 3. Refer to Installation Instructions 579-977 for additional wiring specifications. ---- - - � � ; To other RUI devices - � ���g '� � -- – �s� _0110��II����9��IIII���IIII��D�II�QR���IR����������Q���01���0�l��0 s��uu��u5uo�uruuuo�uioiu�io�u�uu�u�. ,� �; � 4010ES Fire Alarm Control Panel 4606-9102 LCD Annunciators TYCO,SIMPLEX,ancf the product names listed in this naaterial ar�e»�arkr and/or registered marks.Unauthorized use is sdrictly prohibited.National Glectrical Code and NFPA ai'e registered tr-ademarl�s of the National Fire Pr�otecrion Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4606-0002-5 8/2012 www.simplexgrinnell.com OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; FMApproved; IDNet or MAPNET II Communicating Devices MEA (NYC) Acceptance* Addressable Manual Stations � � ���'� '�;��)� Individually addressable manual fire alarm �- stations with: • Power and data supplied via lDNet ar MAPNET II � �� � � � ��' � _c � addressable communications using a single wire pair � • O eration that com lies with ADA re uirements P P q • The NO GRIP Single Action Station and Retrofit Kit � � , are available with a more easily operated pull lever for applications where anticipated users may find the 4099-9001 4099-9020 4099-9805 standard station lever difficult to activate Single action NO GRIP NO GRIP • Pull lever that protrudes when alarmed Single action Retrofit kit • Break-rod supplied(use is optional) � • Models are available with single or double action I� �)� � �,� ���� (breakglass or push)operation - • UL listed to Standard 38 � ` Compatible with the following Simplex°control I panels: � �� i! • Model Series 4100ES,4010ES,4008,4010,4100U, 4020,4100, and 4120 fire alarm control panels 0 0 0 equipped with either IDNet or MAPNET TI communications 4099-9002 4099-9003 With 2099-9828 Model Series 2120 Communicating Device Breakglass Push Institutional � Cover kit Transponders(CDTs)equipped with MAPNET II communications • • ' • Compact construction: Activation of the 4099-9001 single action manual station • Electronics module enclosure minimizes dust requires a firm downward pull to activate the alarm switch. in6ltration CompleYing the action breaks an internal plastic break-rod • Allows mounting in standard elec�rical boxes (visible below the pull lever,use is optional). The use of a • Screw terminals for wiring connections break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for Tamper resistant reset key lock(keyed same as easy activation. The pull lever latches into the alarm Simplex fire alarm cabinets) position and remains extended out of the housing to provide Multiple mounting options: a visible indication. • Surface or semi-flush with standard boxes or matching Single Action NO GRIP Station 4099-9020. For Simplex boxes applicarions such as California Building Code,Title 24, • Flush mount adapter kit which requires"Controls and operating mechanisms shall Adapters are available far retrofitting to commonly be operable with one hand and shall not require tight � available existing boxes grasping,pinching or twisting of the wrisY'the model 4099-9020 station provides a more easily operated pull � - • . lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit lcit. The Simplex addressable manual station combines the Double Action Stations (Breakglass)require the familiar Simplex manual starion housing with a compact operatar to strike tbe front mounted hammer to break the communication module that is easily installed to satisfy g�ass and expose the recessed pull lever. The pull lever then demanding applications.Its integral individual operates as a single action station. addressable module(IAM)constantly monitors status and communicates changes to the connected control panel via Double Action Stations (Push Type)require that a IDNet or MAPNET II communications wiring. spring loaded interference plate(marked PUSH)be pushed back to access the pull lever of the single action station. " Refertopage2faspeaficmodel Iistings.Thisproducthasbeenapprovedbythe Station reset requires the use of a key to reset the manual Califomia State Fre Marshal(CSFN�pursuant to Sedion 13144.1 of the Califomia HealYh station lever and deactivate the alarm switch. (If the break- arxJ Safety Caie.See CSFM Listing 7150-002G:224 for allauable values and/a oonditions corioerning rrateri�prese�,ted in tnis doa,rr�r,t.�t is subjed to re-e�n;nati«,,revision, rod is used, it must be replaced.) �,d���e�r,o�i��or,.a�c�afor�-atyo�r�,Nvor�o�rt�»�r,co�e�,�ia�r,�- Station testin is erformed b h sical activation ofthe NEA3Cr93E.Pdditional listings rrey be�plic�ble;comacc ya,�i«�s��prod�.t 9 P Y P Y �,���-fo�-tr,eiat��tstat�.u����,da�waisu�s���r��«d��.�e pulllever. Electricaltestingcanbealsoperformedby tr,eprop�tyo�TyooFreProcectia,�roducts. unlocking the station housing to activate the alarm switch. S4099-0001-9 5/2012 � . . . . - . . . . Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model Description Housing Pull Lever Listings 4099-9001 Single action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9001CB Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC, FM 4099-9001CF Single action, French ALARME FEU ABAISSEZ 4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Double action, Push operation, English 4099-9020 Single action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Accessories Model Description 2975-9178 Surface mount steel box, red Refer to page 3 for dimensions 2975-9022 Cast aluminum surface mount box, red 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions 579-1007 for details • - . • . • • � • .�• • • . • Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring,for 18 to 14 AWG wire UL Listed Temperature Range 32°to 120° F(0°to 49°C)intended for indoor operation Humidity Range Up to 93% RH at 100° F(38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5"H x 3-3/4"W x 1"D(127 mm x 95 mm x 25 mm) � • • . . - . . . Single Gang Box Mount 4"Square Box Mount Single gang box,2-1/2"deep 4"(102 mm)square box,2-1/8"(54 mm)minimum (64 mm),RACO#500 or equal depth,RACO#231 or equal(supplied by others) (supplied by others) � L� L� L� _ o o Mount flush or with � ° a ° �� 1/16"(2 mm) maximum extension � ° DO NOT RECESS 4"Square box �� � � o �� with cover plate � � � � � C> � i o ' i —� i O � i i Station � F�� \O � side view i � Single gang cover plate,3/4" ; (19 mm)extension,RACO#773 -------- �� �� or equal(supplied by others) 1 Single gang box outline Wall surface� Semi-Flush Mount Side View �+Simplex 2 S4099-0001-9 5/2012 � . . . . . . . 2975-9178 Box 2975-9022 Cast Box Preferred Mounting.For 5-3/16"H x 4"W x 2-3/16"D 5"H x 3-7/8"W x 2-3/16"D surface mounting of these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) (ordered separately) (ordered separately) addressable manual stations,the preferred electrical boxes are � shown in the illustration to the right. 0 0 0 0 Additional Mounting Knockouts located Reference. Refer to page 4 for top and bottom Wiremold box mounting compatibility. � FIRE ��)�I 0 0 PULL DOVUV 1 Access for 3/4"threaded 5.� conduit located top and bottom (127 mm) fi Simplex � 1"(25.4 mm) �-3-3/4"(95 mm)-► � 4099 Series Addressable Manual Station • • - � - � • • • Refer to NFPA 72,the National Fire Alarm and Signaling Code,and all 1-1/4" applicable local codes for complete �3� 2 mm) Simplex 2975-9178 box requirements for manual stations. The Field wiring I�-� (shown for reference) (shown for reference) � following summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed Address setting under in the protected area such that they resealable label(accessible are unobstructed and readily with cover open) �► ■ 2 5�$„ accessible. (67 mm) 2. Mounting shall be with the operable part not less than 42 in Station cover (1.07 m)and not more than 48 in hinges open for (1.22 m)above floar level. installation access � 3. At least one station shall be Switch wiring provided on each floor.Additional (prewired) stations shall be provided to obtain a travel distance not more than 200 ft(6l m)to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be instal led. 3 S4099-0001-9 5/2012 � . . . . - . � . . . . . . . For retrofit and new installations,additional o 0 Wiremold compatible mounting boxes �o �� receptacle box and the required adapter plates 2099-9814 Surface trim model V5744-2 are shown in the illustrarion to for wiremoid box (supp�ied by 5-1/8"H x 5"W others) the right. (130 mm x 127 mm) o O o � o Two gang switch box,each 3"H x 2"W x 2-3/4"D � ��� (76mmx51 mmx70mm) (supplied by others) 4099-90011DNet ° � � addressable station �� �� C � O U U 2099-9813 Semi-flush trim for 2 gang o � � o switch box,6"H x 4-1/2"W (152mmx114mm) ' • • . � - • • • • • Flush mount adapter kit 2099-9819,Black 2099-9820,Beige� Box must be recessed into wall � 1"to 1-1/8"(25.4 mm to 29 mm) � (� ��'�; I � � � 8�� - �� (203 mm) � � Hole cutout must be a minimum of 6"H by 5"W � 6�� (152 mm by 127 mm) � (152 �- mm) �� � � � 4-11/16"(119 mm) square box,2-1/8" (54 mm)minimum Wall depth(by others) -� 4-3/4"(121 mm) -= surface�� . 6-3/4"(171 mm) Front View Side View TYCO,SIMPLEX,and the product names listed in[his material are marks and/or eegi.rtered marks.Unau[horized u.re is steictly�ro{tibited.N!'PA 72 and National I'ire Alarm and Srgnaling Code are trademarks of�the Nafional Fire Proteciion Association(NFPA).Lexan is a trademark of the General F,lech-ic Co. Wiremold zs a trademark of the Wirernold Company. �05 i m p I Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4099-0001-9 5/2012 www.simplexgrinnell.com �O 20/2 Tyco Fire 73 okection Aoducts.Ap nghts reserved.A!!spec�cations and other info�mukon shown were ewrent as of documenk revision date and are subject to change without r2otice. �oSimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors — Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories � TrueAlarm analog sensing provides: • Digital transmission of analog sensor values via IDNet � or MAPNET lI two-wire communications For use with the following Simplex°products: • 4100ES,4100U,4010ES,and 40]0 Series control panels; and 4008 Series control panels with reduced 1 1 feature set(refer to data sheet 54008-0001 for details) — • 4020,4100,and 4120 Series control panels,Universal Transponders,and 2120 TrueAlarm CDTs equipped 4098-9714 TrueAlarm Photoelectric for MAPNET II operation Sensor Mounted in Base Fire alarm control panel provides: • Peak value logging allowing accurate analysis of each � ' • • sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72 sensitivity Digital Communication of Analog Sensing. testing requirements;automatic individual sensor TrueAlarm analog sensors provide an analog calibration check verifies sensor integrity measurement digitally communicated to the host control • Automatic environmental compensation,multi-stage panel using Simplex addressable communications.At the control panel,the data is analyzed and an average value is alarm operation, and display of sensitivity directly in determined and stored.An alarm or other abnormal percent per foot condition is determined by comparing the sensor's present • Ability to display and print detailed sensor value against its average value and time. information in plain English language Intelligent Data Evaluation.Monitoring each sensor's PhotoeleCtric smoke sensors provide: average value provides a continuously shifting reference • Seven levels of sensitivity from 0.2%to 3.7% point. This software filtering process compensates for (refer to addirional informarion on page 3) environmental factors(dust,dirt,etc.)and component Heat sensors provide: aging,providing an accurate reference for evaluating new • Fixed temperature sensing activiry.With this filtering,there is a significant reduction • Rate-of-rise temperature sensing in the probability of false or nuisance alarms caused by shifts in sensitivity,either up or down. • Utility temperature sensing • Listed to UL 521 and ULC-S530 Control Panel Selection.Peak activity per sensor is stored to assist in evaluaring specific locarions. The alarm General features: set point for each TrueAlarm sensor is determined at the • Listed to UL 268 and ULC-S529 host control panel, selectable as more or less sensitive as • Louvered smoke sensor design enhances smoke the individual application requires. capture by direcring flow to chamber; entrance areas Timed/Multi-Stage Selection. Sensor alarm set points are minimally visible when ceiling mounted can be programmed for timed automatic sensitivity • Designed for EMI compatibiliry selection(such as more sensitive at night,less sensitive • Magnetic test feature is provided during day).Control panel programming can also provide • Optional accessories include remote LED alarm multi-stage operation per sensor.For example,a 0.2% indicator and output relays level may cause a warning to prompt investigation while a Additional base reference: 2.5°/o level may initiate an alarm. • For isolator bases,refer to data sheet 54098-0025 Sensor Alarm and Trouble LED Indication.Each • For sounder bases,refer to data sheet 54098-0028 sensor base's LED pulses to indicate communications with the panel.If the control panel determines a sensor is • For photo/heat sensors,refer to data sheet S4098-0024 in alarm,or is dirry ar has some other type of trouble,the (single address)and 54098-0033 (dual address) details are annunciated at the control panel and that sensor ' m��xnd�r,��,a�o�ed eytne c,��fo�„�a st�te F�nro�r,�(csFn���,t to base's LED will be turned on steadily. During a system sect�a,�s�aa.�ortnecai�fa„�a�tnandsarerycode.seecsFrvtust��s alarm the control anel will control the LEDs such that 7272-0026:218,7271-0026231,7270-0026216,and 7300-0026217 fa allo�ble values � p arxuor oonditions ooncernir,g rreterial preserted in tnis doaamer,t.acoepted tor use—atyof an LED indicating a trouble will return to pulsing to help NewYalcDepartmentofBuildings—NEA3.5-93EPdditiaial listingsrrnybeapplicable, identify the alarmed sensors. contact your local Sirrplex product supplier for the latest status.Listirx�s and appra�als under Slrrplex Trre Reca-der Co.are the property of Tyco Rre Rotedion Raluds. S4098-0019-15 4/2013 TrueAlarm Sensor Bases and Accessories ■ - . . . TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the Base mounted address selection: detachable photoelectric or heat sensors. Each sensor's • Address remains with its programmed location output is digitized and transmitted to the system fire alarm • Accessible from front(DIP switch under sensor) control panel every four seconds. General features: Since TrueAlarm sensors use the same base,different • Automatic identificarion provides default sensiriviry sensor types can be easily interchanged to meet specific when substituting sensor types location requirements. This feature also allows intentional • Integral red LED far power-on(pulsing),or alarm or sensor substitution during building construction.When trouble(steady on) conditions are temporarily dusty, instead of covering the • Locking anti-tamper design mounts on standard outlet smoke sensors(causing them to be disabled),heat sensors box may be installed without reprogramming the control panel. Although tbe control panel will indicate an • Magnetically operated functional test incorrect sensar type,the heat sensor will operate at a � default sensitivity providing heat detection for building protection at that location. 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: � � • 2098-9808 Remote LED alarm indiCator or 4098-9822 Electrical Box Requirements:(boxes are by others) relay(unsupervised) Without relav:4"octagonal or 4"square,1-1/2"deep; 4098-9791,Sensor base with supervised relay driver single gang,2��deep output(not compatible with 2120 CDT): w�tn relav:a"octagonal or 4"square,1-1/2"deep, • Relay operation is programmable and can be manually witn i-�/2"extension ring operated from control panel a^(102 mm)Square Box a^(102 mm)Octagonal Box • Use with remote mount 2098-9737 relay surface mount�efe�ence • Also includes wired connections for remote LED alarm indicator or 4098-9822 relay �` � � � � ' U � u �J • • • • 2098-9737, Remote or local mount supervised relay: �-�i2��(38 mm) minimum box depth • DPDT contaCts for resistive/suppressed loads,power Flush mount reference,mount even with final limited Cating of 3 A@ 28 VDC;non-power limited surface,or with up to 1/4"(6.4 mm)maximum recess rating of 3 A@ 120 VAC(requires external 24 VDC ' � ;2098-9737 Relay(mounts in 4098-9822 Relay(mounts � COI� pOWei� ;base electrical box or remotely) in base electrical box) � 4098-9822, LED Annunciation Relay: ; � � ; • Activates when base LED is on steady,indicating local � ; alarm or trouble ' � � ; • DPDT contacts for resistive/suppressed loads,power � ; limited rating of 2 A@ 28 VDC;non-power limited � ; rating of 1/2 A@ 120 VAC,(requires external 24 VDC ; � COIl pOW2T� ; Relay Size: 2-1/2"X 1-1/2"X 1"(375 cubic inches) ; (64mmX38mmX25.4mm) � 4098-9832,Adapter plate: ; � , NOTE:Review total wire count,wire size,and accessories � • Required for surfaCe or semi-flush mounting to � being wired to determine required box volume. ; 4"square electrical box and for surface mounting to '---------------------------------------------% 4"octagonal box �� 6-3/8"(162 mm) � • Can be used for cosmetic retrofitting to existing 6-3/8" dlameteT'baSe pl'OdUCt - � 4098-9832 Adapter Plate,re�c uired for 2098-9808, Remote red LED Alarm ��4�� mounting to surface mounted boxes � (6.4 mm) and 4"sauare flush box Indicator: • Mounts on single gang box �. 4-7/8"(124 mm) -� ALARM (shown in illustration to right) �o �5/�s" (24 mm) p }3�m�� TrueAlarm Bases 4098-9789,-9791,&-9792 � 2 S4098-0019-15 4/2013 TrueAlarm Sensors � , . . � Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Interchangeable mounting compensated, fixed temperature sensing, selectable with EMI/RFI shielded electronics or without rate-of-rise temperature sensing.Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the control panel for either 15°F(8.3°C)or 20°F(11.1°C) Fixed Temp. UL&ULC FM Spacing,Either Fixed per minute. Fixed temperature sensing is independent of Setting Spacing Temperature Setting rate-of-rise sensing and programmable to operate at 135°F 60 ft x 60 ft �0 ft x 20 ft(6.1 m)for fixed 135°F(572°C)or 155°F(68°C).In a slow developing (57.2°C) (18.3 m) temperature only;RTI=Quick 5o ft x 5o ft(�5.z m)for fixed fire,the temperature may not increase rapidly enough to 155°F 4o ft x 40 ft temperature with either rate-of-rise operate the rate-of-rise feature.However,an alarm will be (ss°C) (�2.2 m) selection;RTI=ultra Fast initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelech-ic technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range from 32°F to 155°F(0° C to 68°C).This feature can • Built-in insect screens provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availabiliry. � 1 • ' • • • - • -7/8"(124 mm) TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode ���—�E�status indicator receiver to provide consistent and accurate low power 2-3/8" smoke sensing. Seven levels of sensitivity are available (60 mm) for each individual sensor,ranging from 0.2%to 3.7%per foot of smoke obscuration. Sensitivities of 0.2%,0.5%, and 1%are for special applications in clean areas. Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o. Sensitivity is selected and monitored at the fire alarm 4098-9733 Heat Sensor with Base control panel.* The sensor head design provides 360° smoke entry for WARNING: In most fires, hazardous levels of smoke optimum response to smoke from any direction. Due to its and toxic gas can build up before a heat detection photoelectric operation,air velocity is not normally a device would initiate an alarm. In cases where Life factor,except for impact on area smoke flow. Safety is a factor,the use of smoke detection is highly recommended. -. 4-7/8"(124 mm) - II��LED status indicator . � � � 2-1/8" (54 mm) Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected.Refer to NFPA 72,the National Fire Alarm and Signaling Code. On smooth ceilings, smoke 4098-9714 Photoelectric Sensor with Base sensor spacing of 30 ft(9.1 m)may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-15 4/2013 - � � . . . . . . TrueAlarm Sensor Bases (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base,no options Sensors 4098-9714 and 4098-9733 4"octagonal or 4"square box, 1-1/2"min. depth;or single gang box,2"min.depth Sensor Base with connections for Sensors 4098-9714 and 4098-9733 4"octagonal or 4"square box 4098-9789 Remote LED Alarm Indicator or 2098-9808 remote LED alarm Unsupervised Relay indicator or 4098-9822 relay Note:Box depth requirements depend on Sensors 4098-9714 and 4098-9733 total wire count and wire size,refer to Sensor Base with connections for accessories list below for reference. Supervised Remote Relay and 2098-9737 remote relay(supervised) 4098-9791** connections for Remote Alarm **NOTE:4098-9791 is NOT compatible 2098-9808 remote alarm indicator or With the 2120 CDT Indicator or Unsupervised Relay 4098-9822 relay(unsupervised) TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792,4098-9789, 4098-9733 Heat Sensor and 4098-9791 Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements Remote Mounting requires 4"octagonal or 2098-9737 Supervised Relay,mounts remote For use with 4098-9791 base 4"square box, 1-1/2"minimum depth or in base electrical box Base Mounting requires 4"octagonal box, 2-1/8"deep with 1-1/2"extension ring 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2"minimum depth on single gang stainless steel plate Relay,tracks base LED status Bases 4098-9789 and 4098-9791 4098-9822 (unsupervised,mounts only in base 4"octagonal box,2-1/8"deep with 1-1/2" electrical box) extension ring Required for surtace or semi-flush 4098-9832 Adapter Plate Bases 4098-9792,-9789,&-9791 mounted 4"square box and for surface mounted 4"octagonal box . - . • General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400µA typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mmZ to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Temperature Range 32°to 100°F(0°to 38°C) with 4098-9733 32°to 122°F(0°to 50°C) Operating Temperature Range with 4098-9714 15°to 122°F(-9°to 50°C) Humidity Range 10 to 95%RH Smoke Sensor 4098-9714, Air velocity=0-4000 ft/min(0-1220 m/min) Ambient Ratings Photoelectric Sensor Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737(see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current 270µA,from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO,SIMPLEX,and zhe product names listed ln this material are marks and/a�registered marks.Unauthorized use is strzctly pi�ohibited.NFPA 72 and Nationa7 Fire Alarm and Signaling Code ar�e trademarlrs of the Nalzona[Fire Protecfion Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0019-15 4/2013 www.simplexgrinnell.com OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx Multi-Point Peripherals UL, ULC, CSFM Listed; TrueAlarm CO Sensor Bases for Smoke, Heat, and FMApproved* Photo/Heat Sensors using IDNet Communications � TrueAlarm addressable CO sensor bases contain a carbon monoxide (CO) sensing module providing both CO toxic gas monitoring and enhanced fire detection: ` • Far use with 4100ES,4100U or 4010ES fire alarm control panels(4100U requires software revision 12.05 �'' '� or higher) • CO sensor bases support(and require)a TrueAlarm photoelectric,photo/heat or heat sensor(ordered TrueAlarm CO Sensor Base with Sounder separately) (shown with 4098-9754 Photo/Heat Sensor) • Mode14098-9797 provides standard features, model 4098-9798 also provides a piezoelectric sounder � _� • CO sensor bases are multi-point devices,consume only one TDNet address,and receive both communications 4100ES/4100U/4010ES Control Panel operation and sensor power from the TDNet channel (the sounder summary: base requires separate 24 VDC system power or NAC • CO sensor data is stored and analyzed at the panel;a connection) new CO Service Report provides easy information • Listed to UL 268,Smoke Detectors for Fire Alarm access(see sample on page 3) Signaling Systems and UL 2075, Gas and Uapor . Five(5)year end of life status indication with CO Detectors and Sensors;allowing systems to be listed to sensor expiration notices occurring within l2 months Standard 2034,Single and Multiple Station Carbon and within 6 months,allowing service replacement Monoxide Alanns planning • Listed by ULC to CSA 6.19-01 Residential Carbon • Analog sensor informarion is digitally transmitted to Monoxide Alarming Devices the host control panel via lDNet communications for • Three types of CO influenced operation are available; processing to evaluate and tracic status UL 2034 CO alarm detection;UL 2075 CO(OSHA) • Carbon monoxide concentration in ppm(parts per level monitoring for ventilation control; and million)is available for viewing from the panel user multi-criteria fire sensor analysis with algorithms that interface combines optical and CO gas monitoring information . For OSHA compliant CO gas sensing,CO condition Operation of a CO sensor base with a level may be programmed by concentration(must be photoelectric or a photo/heat sensor allows: above 30 ppm) • Independent sensor operation or selectable multi-sensor General fieatures: modes of False Alarm Reduction or Faster Detection • Operation of a CO sensor base with heat sensor provides • False Alarm Reduction analyzes CO and photoelectric dual independent sensor operation sensor informarion together to provide a sophisticated New CO test mode allows functional testing of each rejection of non-fire conditions normally troublesome as � false alarms(steam,dust,aerosols, etc.) sensar technology including the CO sensor • Faster Detection(increased sensitivity)algorithm • Optional accessories include remote alarm LED,alarm analyzes CO and photoelectric sensor information to relay,and mounting adapter plate allow the presence of CO to implement an increased • Designed for EMI compatibility photoelectric sensitivity for high value locations • Provides magnetic test (museums,electrical equipment rooms, etc.) CO sensor element is easily replaced when end of Sounder base operation details: service life is reached: • When connected to a panel NAC through the 4905-9835 . Access to CO sensor replacement cartridge(CORC, Temporal Code Module,the sounder base can provide 4098-9746)requires removal of interchangeable sensor temporal code 3 (TC3)far fire,or temporal code 4 head providing tamper monitaring(sensor removal (TC4)for toxic carbon monoxide alarms causes a trouble condition) • 4905-9835 module may also be used to code other (non-fire)dedicated carbon monoxide notification • -rns�roductnas�r,a�ro�nytt,�carrorr�astateFren�rsr,�(cs�vrj�rs�,ar,t appliances(refer to data sheet 54905-0006) to sea�a,�s�aa.�o�tne cai�ro�,�a�tn a�,d sarety coae.see csFnn�st�� • Sounder can be manuall activated from the anel ����forallwaadevaluesand/aoonditirnscaicemingrr�terialpresentedin Y P tns doa ir�t.�stirx�and�pp-ova�s urx�Sirrpleac rrre Re�rder co.are the • Sounder operation is also listed to UL 464 as an audible r�a�v��m���n�i�,�m��. notification appliance S4098-0041-7 4/2013 • • - � - � • • • � - - � • � - • • '• Carbon monoxide (CO) is an odorless,colorless, Nuisance Alarm Reduction Details.For applications tasteless gas produced by the incomplete combustion of of anticipated nuisance alarm conditions,photoelectric heating fuels such as wood,coal,heating oil,and natural sensitivity is nonnally selected for 3.7%/ft smoke gas. CO is also a byproduct of many inaterials experiencing obscuration. However,the addition of CO sensing allows unintentional fire or even incipient fire conditions. the host control panel to apply software verification similar Monitoring of CO levels can warn of physically harmful to the rimed alarm verification feature often used with concentrations,however, sensing of CO levels below the conventional smoke detection. harmful level can also provide improved understanding of Faster Fire Detection.For applications where faster incipient fire conditions when evaluated in combination response to incipient ar slow building fires is desired and with photoelectric fire sensor information from the same environment appropriate,the Faster Fire Detection mode locarion. correlates the outputs of the CO sensor and the photoelectric Simplex°CO sensor bases combine an electrolytic CO sensor to provide increased sensitivity. This mode provides sensing module with a TrueAlarm analog sensor to provide earlier detection compared to a standard sensitive a single multiple sensing assembly using one system photoelectric sensor setting,and also provides more false address. The CO sensor can be enabled/disabled,used in alarm reducrion compared to using a sensitive setting in an LED/Switch modes and custom control, and can be made area not normally considered appropriate. public for communication across a fire alarm Network Faster Fire Detection Details. TrueAlarm photoelectric CO sensor operation is similar to other TrueAlarm sensors can be selected to be as sensitive as 0.2%/ft sensors(photoelectric or heat). It provides current analog obscuration for applications evaluated as appropriate to that values,average analog value,"No Answer"troubles, level. However,if the environment is not suitable for that "Wrong Device"troubles,over threshold,concentration in sensitivity level,the Faster Fire Detecrion mode allows the ppm,and monitors far the presence of the CO sensor. Base photoelectric sensor to be selected as a"standard"2.5%/ft mounted address selection allows the address to remain obscuration,but with the presence of a significant level of with its location when the sensor is removed for service or CO,the combination of CO and photo sensing input can type change.Address access is from the front,under the allow an equivalent sensitivity approaching 0.5%/ft removable sensor. An integral red LED indicates power-on obscurarion. The host control panel tracks two photoelectric by pulsing,or alarm or trouble when steady on,and also sensitivities,the one selected for photoelectric operation provides test mode status(see page 3). Detailed status is only(typically 2.5%),and the CO correlation sensitivity available at the fire alarm control panel. that it adjusts depending on the amount of CO present. • • � - - � • � - • • • • • - • Toxic Gas Sensing, UL 2034/UL 2075.For CO toxic Smoke sensor features include: sensitivity gas detection,the bases provide toxic gas sensing to the monitoring sarisfying NFPA 72 sensitivity testing UL 2034 and UL 2075 standards. Toxic gas sensing may be requirements,automatic individual sensor calibration selected at the same time as any of the combined CO photo checking to verify sensor integriry,automaric fire detection modes are selected. environmental compensarion,available multi-stage alarm Toxic Gas Sensing, OSHA Compliant.For OSHA operation,display of sensitivity directly in percent per foot, compliant gas sensing,the desired threshold level (above monitoring of peak activity per sensor,alarm set point,and 30 ppm)is selected at the control panel as required for the time of day ar multi-stage alarm selection. application,rypically for ventilation control. Refer to page 3 Sensor Alarm and Trouble LED Indications.The for additional OSHA CO monitoring information. sensor base LED pulses to indicate communications with Enhanced Fire Sensing.Each sensor provides an the paneL If a sensor is in alarm,or has a trouble condition, analog measurement digitally communicated to the control the status is annunciated at the control panel and that base panel for analysis.At the panel,these analog values are LED will turn on steady. During a system alarm,the panel used separately,or combined,to evaluate for conditions will control LEDs such that a trouble indication will return indicative of fire,incipient fire,excessive heat,and freeze to pulsing to help idenrify the sensors in alarm. warning.For fire,the addition of a CO sensor provides two Reported CO Sensor troubles are: Disabled,Almost new selectable modes of operation:Nuisance Alarm Expired 12 Months,Almost Expired 6 Months,Expired Reduction Mode and Faster Fire Detection.These two (End of Life), Short,and Sensor Missing/Failed. modes were developed using the results of extensive testing Trouble Details."Almost Expired"is similar to the of actual fires performed under a wide variety of conditions. �°Almost Dirry"trouble for a photoelectric sensor. (Refer to page 4 for additional operation mode options.) "Expired"trouble is similar to the"Dirty"�rouble for a Nuisance Alarm Reduction Mode allows the host TrueAlarm photoelectric sensor. CO sensor technology control panel to combine photoelectric sensor input and CO does not support automatic sensitivity testing and drift sensor level input to reduce false alarms caused by non-fire compensation as is available with a photoelectric sensor. conditions.Non-fire conditions can be steam from End of useful CO sensor life is based upon a set 5 year bathroom showers,particles from dusty environments, operational lifetime,tracked by date code built into the CO aerosols from personal care products,tobacco smoke, sensar module electronics. Although the CO sensor wi11 cooking smoke, or other similar conditions. continue to function after the 5 year expired trouble is indicated,replacement is required to ensure proper detection accuracy. 2 S4098-0041-7 4/2013 • • � • - • • '• ` • Panel Test Mode. To facilitate functional tesring of the 2098-9808, Remote red LED CO sensor,a new test mode is available in the host control Alarm Indicator mounts on a � panel.In this mode,the CO sensor,and installed heat or single gang box to provide status smoke sensor can be easily functionally tested. indications where the sensor Panel Test Mode Details. When in the CO test mode, locarion may not be readily a�ARM the internal multiple sensor analysis algorithms are disabled visible. (See illustration to right.) � allowing each sensor to be quickly tested either individually 4098-9822, LED Annunciation or simultaneously,depending on the test equipment used. Relay activates when base LED is CO testing can be performed using a Solo Model 332 on steady,indicating a local alarm �Simplex aerosol dispenser(or equal). (Testing is available through or trouble. Contacts are DPDT, your local authorized Simplex product supplier.)The base rated 2 A@ 30 VDC; 1/2 A@ � LED will display steady ON when individual sensors are 120 VAC for transient suppressed activated during test. Refer to the Application Reference loads(requires externa124 VDC section for more information. coil power). OSHA CO monitoring. For OSHA compliant gas ' � � - • sensing(i.e.parking garages and workplace spaces with Determine sensor locations after careful consideration of the combustion type equipment)control panel software supports the internal programming command"ANALOG Physical layout and contents of the area to be protected. COMPARE"to provide comparisons of CO points. For For fire alarm applications: example,in a custom control equation to turn on a fan or . Refer to NFPA 72,the National Fire Alarm Code vent. "If the CO toxic gas is 50 ppm(or is greater or less . On smooth ceilings,smoke sensor spacing of 30 ft than X ppm)"then turn on control point. The valid concentration range for the opcode is 30 to 563 ppm. (9.1 m)may be used as a guide. For detailed application information: Multi-Point AIIoCation.The host panel requires three(3) . Refer to 4098 Detectors, Sensors, and Bases Application points per CO sensor base with the 4098-9754 multi-sensor, Manual,Part Number 574-709. and two(2)points for the other sensors.Depending on CO sensor base and sensor choice,up to seven(7)points can be For toxic gas sensor placement and mounting: made public to a connected Simplex Fire Alarm Network • Refer to NFPA 720,StandaNd for the Installation of Each CO sensor base uses a single address with each of the Carbon Monoxide(CO) Warning Equipment in Dwelling individual points appearing as"sub-points"layered Units underneath(such as 1-1-0, 1-1-1, 1-1-2, ....1-1-6). . Sensors may be either wall or ceiling mounted (Additional multi-point allocation detail is described in reference data sheet S�4090-0011.) • Per NFPA 720, Section 5.1 (2005 edition): 5.1.1 A carbon monoxide alarm or detector shall be CO Sensor Base Power Requirements.Power for the centrally located outside of each separate sleeping area standard CO sensor base is provided by IDNet in the immediate vicinity of the bedrooms. communications.No additional wiring is required for 5.1.2 Each alarm or detectar shall be located on the wall, upgrading of existing installed Tr�ueAlarm sensor bases. CO ceiling,or other location as specified in the installation sensor sounder bases do require system supplied separate instructions that accompany the unit. 24 VDC(or NAC)wiring,the same as the standard sounder base. � • . . TrueAlarm CO Service Reports (sample below)contain information on the CO sensors programmed in the panel displaying pertinent data such as current concentration value in ppm,End of Life date,and current state.This report allows determinarion of which sensors will require attention. Service Port Page 1 REPORT 6 : TrueAlarm CO Report 12:34:56am WED 10-APR-13 ----------------------------------------------------------------------------------------------- Channel 1 (M1) Zone Current End of Name CUSTOM LABEL Value Life Date State ----------------------------------------------------------------------------------------------- M1-1-2 Conference Room 17 CO Toxic Gas 457PPM 01-APR-18 PRI M1-2-2 Boiler Room CO Toxic Gas OPPM Ol-APR-18 NOR TRUE ALARM CO REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort 3 S4098-0041-7 4/2013 - � � . . . . . . TrueAlarm CO Sensor Base Model Description 4098-9797 CO Base,Standard operation Select TrueAlarm sensor from list below 4098-9798 CO Base with Sounder TrueAlarm Sensors, select one per CO Sensor Base Model Description 4098-9714 Photoelectric Smoke Sensor 4098-9754 Multi-Sensor Photoelectric and Heat Sensing Refer to selection table below for available operation modes 4098-9733 Heat Sensor CO Base Replacement CO Cartridge and Accessories (ordered separately as required) Model Description 4098-9746 CO Replacement Cartridge(CORC) Solo 332 Aerosol Dispenser,suitable for larger diameter detectors;can be used for CO or smoke testing Solo C3 CO Aerosol Canister(case of 12) Model Description Mounting Requirements 4098-9832 Adapter Plate, required for surface mounted 4"electrical boxes Refer to page 6, mounting reference 2098-9808 Choose Remote red LED Alarm Indicator on single gang Single gang box, 1-1/2"minimum depth stainless steel plate one if 4098-9822 required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2" mounted only in base electrical box) extension on 4"square or octagonal box) • • • • - • • • • • • M Operational Mode Choices" (✓ =operation selected) Sensor Choice � d False Alarm Faster TrueSense Photo Heat Utility lon Fire CO Toxic CO e Reduction Detection Photo/Heat Fire Fire*' Temp. Gast Firett Photoelectric 1 ✓ — — — — — — option option Smoke Sensor 4098-9714 2 — ✓ — option — — — option option Photo/Heat 3 ✓ — — — option option — option option Multi-Sensor 4 — ✓ — option option option — option option 4098-9754 5 — ./ option option option option option Heat Sensor 6 — — — — ✓ option — option — 4098-9733 � _ — — — option J — option — " NOTE: Duct detection modes are not applicable and are not available. Each CO base and sensor counts as multiple points against panel point capacity depending on the operations selected at the 4100ES/4100U/4010ES control panel, refer to data sheet S4090-0011 for additional multi-point allocation detail. "Heat Fire Mode is 135° F or 155° F,fixed or rate-of-rise. t CO Toxic Gas operation is selectable as: Supervisory(which is NOT recommended if communicated off-site), Priority 2(preferred if communicated off-site),or Utility. tt CO fire detection mode can be selected only when used with a photoelectric smoke detection sensor set for fire detection mode. 4 S4098-0041-7 4/2013 . 1 1 � � � � � � � � � Sealed against rear air flow entry TrueAlarm multi-sensors combines the performances of Electronics are EMI/RFI shielded TrueAlarm photoelectric smoke sensing with TrueAlarm thermal sensing to provide both features in a single Heat sensing: assembly. Each sensing element provides data for • Selectable rate compensated,fixed temperature evaluation at the fire alarm control panel where the sensing with or without rate-of-rise operation following four independent detection modes are • Rated spacing distance between sensors: evaluated: • Fixed temperature heat detection Fixed Temp. UL&ULC FM Spacing,Either Fixed . Rate-of-rise heat detection Setting Spacing Temperature Setting 2o ft x 2o rt(s.� m)tor fixed • TrueAlarm photoelectric smoke detection 135°F 60 ft x 60 ft • And TrueSense correlation detection (57.2°C) (18.3 m) temperature only;RTI=Quick 5o ft x 5o ft(15.2 m)for fixed TrueSense analysis correlates both thermal activity 155°F 40 ft x 40 ft temperature with either rate-of-rise (ss°c) (�2.2 m) seiection;RTI=Ultra Fast and smoke activity at a single multi-sensor location using an extensively tested covariance relationship.As a Smoke Sensors: result,TrueSense detection improves response to • Photoelectnc technology sensing conditions indicative of faster acting,hot flaming fires when compared to the response of either photoelectric • 360°smoke entry for optimum response smoke activity or thermal activity alone. • Built-in insect screens , � • • • � ' � ' � ' ' • • - - • TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with TrueAlarm photoelectric sensors use a stable,pulsed or without rate-of-rise temperature sensing. Due to its infrared LED light source and a silicon photodiode small thermal mass,the sensor accurately and quickly receiver to provide consistent and accurate low power measures the local temperature for analysis at the fire smoke sensing. Seven levels of sensitiviry are available alarm control panel. far each individual sensor,ranging from 0.2%to 3.7%per foot of smoke obscuration. Sensitivities of 0.2%,0.5% Rate-of-rise temperature detection is selectable at the and l%are for special applications in clean areas. control panel for either I S°F(8.3°C)or 20°F(1 l.1° C) Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o. per minute. Fixed temperature sensing is independent of Sensirivity is selected and monitored at the fire alarm rate-of-rise sensing and programmable to operate at control panel.* 135°F(57.2°C)or 155°F(68°C).In a slow developing fire,the temperature may not increase rapidly enough to The sensor head design provides 360° smoke entry far operate the rate-of-rise feature.However,an alarm will be optimum smoke response.Due to its photoelectric initiated when the temperature reaches its rated fixed operation, air velocity is not normally a factor,except for temperature setting. impact on area smoke flow. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range = sai�s°��sa mm> 'I from 32°F to 155°F(0° C to 68°C).This feature can 2-5/16°(58 mm) provide freeze warnings or alert to HVAC system LED status indicator problems. i � � = 6-7/16"(164 mm) – I, � � 2-7/16" � I (62 mm) � 1 � __ _-----— Output louvers on � � Sounder Base extend � CO sensor Thermistor guard� from front and side 2-9/16" 1 housing (Multi-Sensor only) (65 mm) � Dimension and Feature Reference, Photoelectric or Multi-Sensor on CO Sensor Base t— _ ' • • • 4098-9733 Heat Sensor with CO Sensor Base Sensor locations should be determined only after carefizl (with CO Sensor Housing facing forward) consideration of the physical layout and contents of the WARNING: In most fires, hazardous levels of smoke area to be protected. Refer to NFPA 72,the National Fire and toxic gas can build up before a heat detection AlaNm and Signaling Code. On smooth ceilings, smoke device would initiate an alarm. In cases where Life sensor spacing of 30 ft(9.1 m)may be used as a guide.* Safety is a factor,the use of smoke detection is highly recommended. * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 5 S4098-0041-7 4/2013 . Electrical Box Requirements: (boxes are by others) Without relav:4"octagonal or 4"square, 1-1/2"deep;single gang,2"deep With relav:4"octagonal or4"square, 1-1/2"deep,with 1-1/2"extension ring 4"(102 mm)Square Box 4"(102 mm)Octagonal Box Surface mount reference � 1-1/2"(38 mm) � � �1 �minimum box depth � + ��� Flush mount reference, mount even with final surface,or with up to 1/4"(6.4 mm)maximum recess ----------------------------- ; O�tional 4098-9822 Relav � � ' (Mounts in base electrical box � � , Note: Single gang ; and requires additional � adapter plate(RACO ; volume,see notes below) ' � � No.787 or equal)is � ; required when using 4" � � square box(by others) � � � Relay size: � ; 2-1/2"X 1-1/2"X 1" � � ; (64mmX38mmX � ; 25.4 mm),3.75 cubic inches � �----------------------------� 4098-9832 Adapter Plate, required for mounting 6-3/8"Dia. �� �to surface mounted boxes(mounts inverted) x 1/4"thick �= 6-7/16"(164 mm) -� � 1-1/8" (29 mm) ♦ CO sensor assembly (CORC)shaded for reference LED status indicator (Photoelectric sensor shown for reference) NOTES: 1. Review actual wire size,wire count, box type,and whether 4098-9822 relay is used before determining box size. 2. Mounting to flush mounted box also fits single gang handy box,2-1/8"(51 mm)deep if wiring allows. (Not applicable if 4098-9822 relay is used.) 3. For surface mounted boxes, use 4"square box with single gang adapter plate(RACO No. 787 or equal, by others)or 4"octagonal box, both require 4098-9832 Adapter Plate. 4. When 4098-9822 relay is used, mount relay in electrical box and use 1-1/2"extension ring(by others)on 4" square or octagonal box of 1-1/2"or 2-1/8"depth as required. 5. Refer to sensor base Installation Instructions 574-707 for additional information. 6. Refer to CORC Replacement Instructions 579-791 for CO cartridge installation and replacement. 6 S4098-0041-7 4/2013 . - , . General Operating Specifications IDNet Communications and Sensor Supervisory Power 24-40 VDC w/data,400µA typical, 1 address per base,supplied by control panel Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2) Current 1 mA typical supplied from communications, no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Temperature Range 32° F to 100° F(0°C to 38°C) Operating with 4098-9733 32° F to 122° F(0°C to 50°C) Temperature Range with 4098-9714 or 4098-9754 15° F to 122° F(-9°C to 50°C) Humidity Range 15 to 95% RH CO Sensor Base Photoelectric Sensor 4098-9714 Air Velocity Ratings and Multi-Sensor 4098-9754 Air velocity=0-1000 ft/min(0-305 m/min) perSensor Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(Sounder On) 17 mA @ 24 VDC,24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Sounder Output Appliance; UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems and CSA 6.19-01 Supervised Select for continuous 24 VDC power, loss of power is communicated to Sounder Power Supervision panel (Selectable) Select when connected to NAC for sounder power, NAC provides Unsupervised supervision NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized pattern(Temporal or March Time,etc.)controlled by the NAC control Standards Reference for CO Monitoring Concentration Alarm Window 70±5 ppm 60 to 240 minutes Requirements Reference for Response Time 150±5 ppm 10 to 50 minutes UL 2034 and CSA 6.19-01 400±10 ppm 4 to 15 minutes False Alarm 30±3 ppm No Alarm for 30 days Resistance 70±5 ppm No Alarm for 60 minutes UL 2075 Reference, Commercial OSHA Type For operations required at lower concentrations than those of UL 2034, Operation such as start ventilation after 5 minutes at 25 to 35 ppm and to alarm at a reading higher than that range, but lower than UL 2034 allows 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended (wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base � • • . . . Product Data Sheet Temporal Code 4 Module S4905-0006 Standard Bases S4098-0019 Isolator Bases S4098-0025 Standard Sounder Base S4098-0028 TrueSense Multi-Sensor S4098-9024 Dual Address Multi-Sensor S4098-0033 7 S4098-0041-7 4/2013 �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0041-7 4/2013 www.simplexgrinnell.com �2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice. �oSimplEx Non-Addressable Peripherals UL, ULC, CSFM Listed; 4905-9835 Temporal Code 4 FM Approved* Module for CO Gas Alarm Notification � Provides Temporal Code 4 (TC4) NAC (Notification Appliance Circuit) control for Carbon Monoxide � � (CO) gas warning: • The TC4 CO gas warning is a repeated sequence of four o OO � tt � O o cycles of 100 msec on with 100 msec off,followed by 5 seconds off per NFPA 720,Standard for the � Installa2ion of Carbon Monoxide(CO) Warning , `"�;_;,;•.. Equipment in Dwelling Units ' � ' • Compatible appliances includes: CO Sounder Base 4098-9798,4901-9820 Horn(set for free-run),and 4903 0 0 Series 4-wire AN appliances horn input(not compatible �������� with SmartSync horn control appliances) � � Compatible Simplex°equipment NAC sources: • 4100ES,4100U,or 4010ES NAC outputs 4905-9835 Temporal Code 4 Module • 4009 IDNet NAC Extender NAC outputs (shown approximately 1/2 size) • Each module requires an input NAC that powers the 3A rated output NAC far control of comparible audible � - . . • -� notification appliances only(notforstrobes) Three selectable operation modes: CO gas alarm, or fire alarm.Use of the 4905-9835 • Synchronized operation allows a separate and Temporal Code 4 Module allows Yhe NFPA 720 Temporal dedicated control NAC to both activate and synchronize Code 4 signal to be generated using a standard Steady On audible appliance NAC input.Under the fire alarm panel's the Temporal Code 4 output timing of up to 20, control,the audible notification signal can be selected for a 4905-9835 modules conventional fire pulse pattern for a fire alarm condition,or • Unsynchronized operation also allows the separate and the Tempora] Code 4 pattern can be acrivated for a CO gas dedicated control NAC to activate the Temporal Code 4 alarm condition. output timing of Lip to 20,4905-9835 modules,but without synchronizarion between the modules . - . . • Stand-Alone operation allows the input NAC in alarm to activate Tempora] Code 4 timing for NACs dedicated For 24 VDC NACs, up to 3 A for CO gas alarm;no fire alarm signals are available,no maximum, limited by input NAC control NAC is used NAC Control rating;for control of audible • For both Synchronized and Unsynchronized modes, notification appliances compatible when the control NAC is off,the module output NACs with TC4 code pulse duty cycle will follow the fire alarm signals of the input NAC Input NAC Current Supervisory current=0.18 mA • NOTE: For TC4 output,both the input NACs and the Requirements Alarm current= 15 mA control NACs requires a Steady On signal Control NAC Current Supervisory current=0 mA CompBCt, S@81@d COIIStI'UCt1011: Requirements Alarm current=3 mA • Mounts in standard 4"square electrical box Mounting Distance Mount close-nippled,20 ft(6 m) • Screw terminals for wiring connections to input NAC Source maximum distance Listed to UL Standard 864 and ULC Standard S527 Screw terminals for in/out wiring, Wire Connections 18 to 12 AWG wire (0.82 to 3.31 mm2) , . � � Dimensions 4"x 4'/8"x 1 '/8'D CO gas alarm warnings are required to be different from (102 mm x 105 mm x 35 mm) fire alarm warnings. In the event of a CO gas alarm,the Mounting Plate Sheet metal,galvanized presence of a Temporal Code 4 audible signal pattern Material identifies the type of condition to the responders to assist in Temperature Range 32°to 120° F(0°to 49°C), determining the proper actions to be taken. intended for indoor operation Humidity Range Up to 93°/o RH at 100° F(38°C) `This product has been approved by the Califania State Fre Nl�rshal(CSFM)pursuarit to Section 13144.1 of the Califania Fie�th and SaFety Code.See CSFM Listing 730Q0026:328 fa allava�le v�ues arxUor conditia�s oor�cerning rreterial presented in this doaarrent.This proaud was r,ot accepcea by n�EA(rwc)�ot aoa irr�rrt revisia,ckk�te.acaitla,al�istings rrgy be applicade;caitact your local Sirrplex product supplier for the latest status.Listings arid approvals urid�Sirrplex Time Reca-der Co.are the properly of Tyoo Rre Prdedion Products. S4905-0006-5 4/2013 . . 4905-9835 Temporal Code 4(TC4)Module __--- -----___ Dedicated control NAC I 4098-9798 CO 4901-9820 Horn,4903 Series 4-wire A/V horn, -�__°9= o? � Sensor Sounder or other compatible(not SmartSync control) � �I Base* 24 VDC audible notification appliances NAC input to TC4 `� 0 1 _ / " Module,3 A maximum � f I ���� iiiiimii���ini�iiipiiiiiiiiiiiiiiiiiiiii� TC4 NAC output,3 A maximum namiiiii�ii�muim�iiiaiiiiiiiiiiiiiiiiiiiiiioo Dedicated control NAC to the next Temporal Fire Alarm Control Panel Code 4 Module, up to 20 total maximum; requires (4100ES shown for reference) � �' end-of-line resistor per source NAC requirements IDNet or RUI Communications per system requirements =____�_____ ° ° ______=_=_' —� Appliance NACs require a end-of-line resistor per � �o�,� source NAC requirements 4009 IDNet NAC Extender(shown, uses IDNet �Note: IDNet communications wiring communications)or Remote 4100ES MINIPLEX (not shown)is required to connect transponder with NACs(uses RUI communications) to each 4098-9798 CO Sensor SounderBase . . Mounting Box(supplied separately),4"square (102 mm), minimum depth=2-1/8"(54 mm), ��� RACO 232 or equal �-�� > � 0 0 , � o �, � 0 ���,�� � �� 0 ����b�q� o � �.Et; �"1Wqjl .,F i�.,y. §`I :P� _ I 0� ,i 0 / � 4"square cover plate, RACO 752 or equal (supplied separately) � . • . Document Description Document Description 579-840 Installation Instructions S4010-0004 4010ES Control Panel S4098-0041 CO Sensor Base data sheet S4901-0010 4901-9820 Horns S4100-0031 4100ES Basic Reference S4903-0011 4903 Series 4-wire A/Vs TYCO,SIMPLEX,and the product nantes listed in ehis malerial are marks and/or registered marks.Unauthonzed iuce is strictly prohibited.NFPA is a trademark of the Natioixa/Fire Protection Aa�sociation. �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4905-0006-5 4/2013 www.simplexgrinnell.com �2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice. �oSimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Sounder Base 4098-9794 for use with MEA (NYC) Acceptance* TrueAlarm Photoelectric and Heat Sensors � Modular TrueAlarm sensor base with built-in electronic alarm sounder: • Piezoelectric sounder provides high output(88 dBA) with low current requirements(20 mA) • For use with interchangeable TrueAlarm photoelectric or heat sensors(ardered separately) --`� Sounder operation details: TrueAlarm Photoelectric Sensor Mounted in • Powered from 24 VDC or from a compatible Sounder Base 4098-9794 Notification Appliance Circuit(NAC) • Synchronized via communications or by the NAC, if ' ' ' - • • • � ' • • NAC powered** • Sounder can be manually activated from the control panel Sounder bases combine an audible notification appliance • Sensor and sounder operation is listed to UL Standard 268 and a TrueAlarm analog sensor to provide: • Sounder operation is also listed to UL Standard 464 Digital Communication of Analog Sensing. as an audible notification appliance Sensors provide an analog measurement that is digitally TrueAlarm analog sensing operation: communicated to the control panel where it is analyzed • Analog sensor information is digitally communicated and an average value is determined and stared.An alarm to the control panel via lDNet or MAPNET II or other abnormal condition is determined by comparing two-wire communications the sensor's present value against its average value. • Sensor information is processed by the control panel Intelligent Data Evaluation.Monitoring each sensor's to determine sensor status average value provides a software filtering averaging For use with the following Simplex°produCts: process that compensates for environmental factors(dust, • 4]OOES,401 OES,4010, and 4]OOU Series control dirt,etc.)and component aging,providing an accurate panels; and 4008 Series control panels with reduced reference for evaluating new activity. The result is a feature set(refer to data sheet 54008-0001 far details) significant reduction in the probability of false or • 4020,4100,and 4120 Series control panels,and nuisance alarms caused by shifts in sensitiviry,either up Universal Transponders equipped for MAPNET II or down. operation Control Panel Selection.Peak activity per sensor is General features: stored to assist in evaluating specific locarions. The alarm • Louvered smoke sensor design enhances smoke set point for each TrueAlarm sensor is determined at the capture by directing flow to chamber; entrance areas control panel,selectable as more or less sensitive as the are minimally visible when ceiling mounted individual application requires. • Designed for EMI compatibiliry Magnetic test feature is provided Timed/Multi-Stage Selection.Alarm set points can be • Optional accessories include remote LED alarm programmed for timed automaric sensitiviry selection indicator and output relays (such as more sensitive at night,less sensitive during day). Control panel programming can also provide Additional base reference: multi-stage operation per sensor.For example,a 0.2% • For standard bases,refer to data sheet S4098-0019 level may cause a warning to prompt investigation while a • For isolator bases,refer to data sheet S4098-0025 2.5%level may initiate an alarm. • For photo/heat sensors,refer to data sheet 54098-0024 Sensor Alarm and Trouble LED Indication.Each (single address)and S4098-0033 (dual address) sensor base's LED pulses to indicate communications with the panel.If the con�rol panel determines that a ' Thisproducthasbcenapprwedtr�theC�'rfariaStateFreN�rsh�(CSFN�pursuanttoSeUion sensor is in alarm, or that it is dirty or has some other type �3�`�a.�o�u�c��o�„�a�m�,ds�avc«�.s�c�t��ti���a�o"�s2���,d of trouble,the details are annunciated at the control panel rn�-0ozs:zs�ra�a�io�eva��,esana�a-o�tia,s�;r�rr�eria�p-�a,rea�ntns and that sensor base's LED will be turned on steadil cbaarrerit.F�ed for use—Qty of Ne�Yaic De{�er4rerrt of�ailc�ngs—NFP3�r�iE Pdc�tia�al 5'• IisCingsrraybeapplicable,oorrtacl�rourlocalSlrrplacprak�ctsupplierfa-thel�estsYahs.Listings During a system alarm,the control panel will control the andap�xwalsux�-S�rrpexrmeR�rderco.aretne�xo�erryorTycoFreProtectia, LEDs such that an LED indicatin a trouble will return to Products. g ""Tdalqua�tityofsande�-l�ase,a2ilablefaoodingonthesanecormliticationsd�r�elrreyvary Pulsing to help identify the alarmed sensors. �th pand application and av�labiliry of I�po.n�-.REfer to spedfic aritrd par�l requirerrents. S4098-0028-7 4/2013 � . . . . . - . . Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type change. Access is from the Electrical Box Requirements:(boxes are by others) front under the removable SensOr. Without relav:4"octagonal or 4"square, 1-1/2"deep;single gang, 2"deep Automatic sensor type identification provides With relav:4"octagonal or 4"square,1-1/2"deep,with 1-1/2" default sensitiviry when substituting sensor types. extension ring Different sensor types can be easily interchanged to meet a°(102 mm)Square Box a°(102 mm)Octagonal Box specific location requirements. This feature also allows Surface mount reference intentional sensar substitution during building - construction. When conditions are temporarily dusty, � , instead of covering the smolce sensors(causing them to be �-�/2°(3s mm� �1 �minimum box depth � �� � disabled),heat sensors may be installed without reprogramming the control panel. Flush mount reference,mount even with final Illt@gl'al 1'@d LED indicates power-on by pulsing,or surface,or with up to 1/4"(6.4 mm)maximum recess alarm or trouble when steady on.The exact status is annunciated at the fire alarm control panel. � � ; Optional 4098-9822 Relav � Fire alarm control panel provides: � ; (Mounts in base electrical box ; Note:Single gang ; and requires additional � • Peak value logging allowing accurate analysis of each adapter plate(RACO ; volume,see notes below) � sensar for individual sensitivity selection No.787 or equal)is � � • Sensihvity monitoring satisfying NFPA 72 sensitivity required when using 4" ; � square box(by others) � Relay size: � testing requirements;automatic individual sensor � , calibration check verifies sensor inte rit ; 2-v2"x�-v2"x��� � g y O ; (64mmX38mmX � • Automatic environmental compensation,multi-stage ; 25.4 mm),3.75 cubic inches � �---------------------------- alarm operation,and display of sensitiviry directly in 6-3/8"Dia. pel'Cent peT fOOt x 1/4".thick 4098-9832 Adapter Plate,reauired for mounting • Ability to display and print detailed sensor \�` �to surface mounted boxes(mounts inverted) information in plain English language �. 6-7/16"(164 mm)� � • � 1-1/8„ 4098-9822, LED Annunciation Relay activates when (2s mm base LED is on steady, indicating a local alarm or trouble. � Contacts are DPDT,rated 2 A@ 30 VDC; 1/2 A@ � 120 VAC for transient suppressed loads(requires external �ED status sound output�ouvers 24 VDC COt�poWeT�. indicator extend from front to side 2098-9808, Remote red LED Alarm Indicator mounts on a single gang box to provide status indications where the sensor location may not be readily visible. (Photoelectric sensor shown for reference) � NOTES: 1. Review actual wire size,wire count,box type,and whether 4098-9822 relay is used before determining box size. ALARM 2. Mounting to flush mounted box also fits single gang handy box, � 2-1/8"(51 mm)deep if wiring allows.(Not applicable if 4098-9822 relay is used.) 3. For surface mounted boxes,use 4"square box with single gang adapter plate(RACO No.787 or equal,by others)or 4"octagonal 435implex box,both reauire 4098-9832 Adapter Plate. 4. When 4098-9822 relay is used,mount relay in electrical box and use �l 1-1/2"extension ring(by others)on 4"square or octagonal box of 1-1/2"or 2-1/8"depth as required. 5.Refer to Installation Instructions 574-707 for additional information. 2098-9808 Remote LED Alarm Indicator 2 S4098-0028-7 4/2013 � � • • � , � • • � Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Electronics are EMI/RFI shielded compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operarion alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the Fixed Temp. UL&ULC FM Spacing,Either Fixed Control panel for either 15°F(8.3°C)or 20°F(ll.l° C� Setting Spacing Temperature Setting per minute. Fixed temperature sensing is independent of 135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fxed rate-of-rise sensing and programmable to operate at (57.2°C) (18.3 m) temperature only;RTI=ciuick 135°F(57.2°C)or 155°F(68°C).In a slow developing 5o ft x 50�t(�52 m�tor fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-rise (ss°c) (�2.2 m) selection;RTI=Ultra Fast operate the rate-of-rise feature. However,an alarm will be initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelech-ic technology sensing TrueAlarm heat sensors can be programmed as a urility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range • Built-in insect screens from 32°F to 155°F(0° C to 68°C).This feature can provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availabiliry. � 1 • ' ' • • - • I I� 6-7/16"(164 mm)- ►I Tr�ieAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available 2-9/16° for each individual sensor,ranging from 0.2%to 3.7%per (65 mm) foot of smoke obscuration. Sensitivities of 0.2%,0.5%, and 1%are for special applications in clean areas. � Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7%. - - Sensitivity is selected and monitored at the fire alarm control panel.* 4098-9733 Heat Sensor with 4098-9794 Sounder Base The sensor head design provides 360° smolce entry for optimum smoke response.Due to its photoelectric WARNING: In most fires, hazardous levels of smoke operation, air velocity is not normally a factor,except far and toxic gas can build up before a heat detection impact on area smoke flow. device would initiate an alarm. In cases where Life Safety is a factor,the use of smoke detection is highly = 6-7/16"(164 mm) - C@COITIITI@IIC�@C�. * I i ` � � • � Sensor locations should be determined after careful 2-5i16" consideration of the physical layout and contents of the �5a mm� area to be protected. Refer to NFPA 72,the National Fire � _ Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft(9.1 m)may be used as a guide. For detailed application information,refer to 4098 4098-9714 Photoelectric Sensor with Sounder Base Detectors, Sensors, and Bases Application Manual,Part Number 574-709.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0028-7 4/2013 - � � . . . . . . TrueAlarm Sounder Base* Model Description Compatibility Mounting Requirements Sounder Base with connections Sensors:4098-9714 and 4098-9733 4098-9794 for Remote LED Alarm Indicator Refer to page 2,mounting reference or Unsupervised Relay Options:2098-9808 remote LED alarm indicator or 4098-9822 relay TrueAlarm Sensors (ordered separately) Model Description Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Refer to page 2,mounting reference 4098-9733 Heat Sensor Sounder Base Accessories (ordered separately if required) Model Description Mounting Requirements 4098-9832 Adapter Plate,required for surface mounted 4"electrical boxes Refer to page 2,mounting reference 2098-9808 Remote red LED Alarm Indicator on single gang Single gang box, 1-1/2"minimum depth Choose one if stainless steel plate required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2" 4�9$-9822 mounted only in base electrical box) extension on 4"square or octagonal box) 'Refer to data sheet S4098-0019 for other compatible bases. Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. • - . . General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400µA typical, 1 address per base,supplied by control panel Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2) Current 1 mA typical supplied from communications, no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Temperature Range 32°F to 100° F(0°C to 38°C) Operating With 4098-9733 32°F to 122°F(0°C to 50°C) Temperature Range With 4098-9714 15°F to 122°F(-9°C to 50°C) Humidity Range 10 to 95%RH Smoke Sensor 4098-9714, Air velocity is 0-4000 ft/min(0-1220 m/min) Ambient Ratings Photoelectric Sensor Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(Sounder On) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Sounder Output Appliances and UL Standard 268,Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel (Selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized pattern(Temporal or March Time,etc.)controlled by the NAC 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base TYCO,SIMPLEX,and the product names listed i�a this mater�ia[are mcmks arad/or regi,rtered marks.(Jrtauthorize�l use is strictly prohibited.NFPA 72 arad National Fire Alar�m and Signaling Code m�e trademarlcr of ihe Nadaoraa!Fir•e Protection Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0028-7 4/2013 www.simplexgrinnell.com OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx TrueAlarm Multi-Point Analog Sensing UL, ULC, CSFMListed; FMApproved; TrueAlarm Multi-Sensor Model 4098-9754 MEA (NYC) Acceptance* Providing TrueSense Early Fire Detection � TrueAlarm photoelectric smoke sensing and heat sensing combined in one housing to provide: • Smoke activity accurately monitored by TrueAlarm �� photoelectric sensing technology • Thermal activity accurately monitared by TrueAlarm thermistor sensing technology • And TrueSense detection,a correlation of smoke �ti activiry and thermal activity providing intelligent fire detection earlier than with either activity alone For use with Simplex°4100ES, 4010ES, and 4100U fire alarm control panels: TrueAlarm Multi-Sensor 4098-9754 Mounted in Standard Sensor Base • TrueAlarm analog sensor information is digitally coinmunicated to the control panel via lDNet _ � � � _ � � two-wire communications • Special point types allow the 4098-9754 multi-sensor TrueAlarm multi-sensor mode14098-9754 combines the to communicate smoke and heat analog sensing data established performances of a TrueAlarm photoelectric using only one IDNet address smoke sensor with a fast-acting and accurate TrueAlarm Individual sensor information is processed by the host thermal sensor to provide both features in a single • control panel to determine sensor status and to sensor/base assembly. determine whether conditions are normal,off-normal, Digital Communication of Analog Sensing. or alarm Analog information from each sensor is digitally • (4100U fire alarm control panels require software communicated to the control panel where it is analyzed. revision 11 or higher with multi-point compatible IDNet photoelectric sensor input is stored and tracked as an transmission modules) average value with an alarm or abnormal condition being determined by comparing the sensor's present value Alarms can be determined by either: against its average value. Thermal data is processed to • Smoke detection with selectable sensitivity from 0.2 look for absolute or rate-of-rise temperature as desired. to 3.7%/ft obscuration(refer to additional informarion on page 2) Intelligent Data Evaluation.Monitoring each photoelectric sensor's average value provides a software • Heat detection selectable as fixed temperature or fixed filtering process that compensates for environmental with selectable rate-of-rise factors(dust,dirt,etc.)and component aging,providing • TrueSense intelligent analysis of the combination of an accurate reference for evaluating new activity. The smoke and heat activity result is a significant reduction in the probability of false Additional design features: or nuisance alarms caused by shifts in sensitivity,either Functional and architecturally styled enclosures for up or down. Status indications of dirty and excessively • ceiling ar wall mounting dirty are automatically generated allowing maintenance to be performed per device. • Smoke sensor louver design that directs air flow to chamber enhancing smoke capture Control Panel Selection.Peak activity per sensor is • Built-in magnetic test feature stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the • Compatible with standard bases(including relay control panel,selectable as more or less sensitive as the control),sounder bases,and isolator bases individual application requires. • Designed for EMI compatibility Multi-Point Reporting and CO Base Reference. UL listed to Standard 268 Reporting 4098-9754"sub-points"under its single address varies witb the base used.Muti-point details are *This p'oduct has bcen approved by the Califomia State Fre N}arshal(CSFfV�pursuarrt to Sedion 13144.1 of the Califomia H�Ith and SaFety Code.See CSFM Listirx,7s listed in data sheet 54090-0011. 7272-0026:218and7300-00'16:217fa-alloxablev�uesarxVorcoriditionsoor�ning Usin the 4098-9754 with CO sensor bases is detailed in rrgterial presented in this doaamerrt.It is subjed to re-exanination,revision,arxJ possible g car,oel�atia,.Pooeptedrause—atyorNewvaicoepartrrernoraui�air�—n�Fa�s3E. data sheet 54098-0041. Refer to page 4 fa ULC listing status.Pdditional listings rrey be ap�licable;cbntact your local Sirrplex procluct supplier fa-the latest status.Listirx,�s�d approvals under Sirrplex Tirre FZeoorder Co.are the prq�erty of Tyoo Fre Protedion Products. S4098-0024-8 11/2012 ■ - � • • '• • � - Timed/Multi-Stage Selection.Alarm set points can be TrueAlarm heat sensors monitor a fast reacting programmed for timed automatic sensitiviry selection thermistar providing operation that is self-restoring and (such as more sensitive at night, less sensitive during rate compensated.Due to its small thermal mass,the day). Control pane]programming can also provide sensor accurately and quickly measures the]ocal multi-stage operation per sensor. For example,a 02% teinperature for analysis at the fire alarm control panel. level may cause a warning to prompt investigation while a The control panel allows alarm selection to be per sensor 2.5°/o level may initiate an alarm. as fixed temperature,or rate-of-rise temperature,ar the Sensor Alarm and Trouble LED Indication.Each combination of both. sensor base's LED pulses to indicate communicarions Temperature Detection.Rate-of-rise temperature with the panel.If the control panel determines that a detection is selectable at the control panel for either 15°F sensor is in alarm,or that it is dirty or has some other type (8.3°C)or 20°F(ll.1° C)per minute.Fixed temperature of trouble,the details are annunciated at the control panel sensing is independent of rate-of-rise sensing and and that sensor base's LED will be turned on steadily. selectable to operate at 135°F(57.2°C)or 155°F During a system alarm,the control panel will control the (68°C).In a slow developing fire,the temperature may LEDs such that an LED indicating a trouble will return to not increase rapidly enough to operate the rate-of-rise pulsing to help identify the alarmed sensors. feature.However,an alarm will be initiated when the - � � . . . temperature reaches its selected fixed temperature setting. Utility Temperature Monitoring. TrueAlarm heat General mechanical: sensors can be programmed as a utility device to monitor • Housing is sealed against rear air flow entry for temperature extremes in the range from 32°F to • Electronics are EMI/RFI shielded 122°F(0°C to 50°C). This feature can provide freeze Smoke sensing: warnings or alert to HVAC system problems. • Photoelectric light scattering sensing technology ' � ' ' • � ' • 360°smoke entry for optimum response Control Panel Sensor Analysis. Each multi-sensor's • Chamber screen provides protection from dirt,dust, and smoke and heat sensing element provides data for insects evaluation at the fire alarm control panel where four Heat sensing: independent detecrion modes are evaluated. They are: • Fast response thermistar design • Fixed temperature heat detection • Rate compensated, self-resetting operation • Rate-of-rise heat detection • Control panel can select per sensor for fixed temperature • TrueAlarm photoelectric smoke detection sensing,rate-of-rise temperature sensing,or the • And TrueSense correlation detection combination of both Comparing Photoelectric Activity and Thermal - � . . _ � � _ Activity.TrueSense analysis correlates both thermal activity and smoke activity at a single multi-sensor TrueAlarm photoeleCtric sensors Lise a stable, location using an extensively tested covariance pulsed infrared LED light source and a silicon photodiode relationship.As a result,TrueSense detection improves receiver to provide consistent and accurate low power response to conditions indicative of faster acting,hot smoke sensing. Seven levels of sensitiviry are available flaming fires when compared to the response of either far each individual sensor,ranging from 0.2%to 3.7%per photoelectric smoke activity or thermal activity alone. foot of smoke obscuration. Sensitivities of 0.2%,0.5%, and 1%are for special applicarions in clean areas. High Integrity Detection. TrueSense operation Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o. provides early fire detection and maintains the established Sensitivity is selected and monitored at the fire alarm �igh level of immunity to false alarms and nuisance control panel. * alarms that is inherent with TrueAlarm sensor operation. Sensor head design provides 360° smoke entry for � ' ' • ' optimum smoke response.Because of the photoelectric Sensor locations should be determined after careful sensing technology,the 4098-9754 sensor is UL listed for consideration of the physical layout and contents of the air velocity of up to 4000 ft/min.However,care must be area to be protected. Refer to NFPA 72,the National Fire taken in determining sensor locations to avoid areas Alarm and Signaling Code. On smooth ceilings, smoke where local airflow may also impact any smoke flow. sensar spacing of 30 ft(9.1 m)may be used as a guide.* (Refer to the application reference section on this page.) " For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual, document number 574-709. 2 S4098-0024-8 11/2012 . � . . • • Base mounted address selection allows the address • Peak value logging allows accurate analysis for of the multi-sensor base to remain witb its programmed sensitivity selection location when the sensor is removed for service. . Automatic, once per minute individual sensor calibration Integral red LED indicates power-on by pulsing,or check verifies sensor integrity alarm or trouble when steady on,reflecting status of either • Multi-stage alarm operation sensor. The exact status of the specific sensing element is . Selectable alarm verification annunciated at the fire alarm control panel. . ALrtomatic environmental compensation and - � . . • determinarion of dirry and excessively dirty • Individual smoke sensitivity and temperature operation • TrueSense analysis of smoke and heat activity is selectable for each sensor • Ability to display and print detailed sensor information • Sensitivity monitoring that satisfies NFPA 72 sensitivity in plain English language testing requirements • Smoke sensitivity displayed in percent per foot and temperature readings selectable as Fahrenheit or Celsius . • Electrical boxes are supplied by others,refer to notes below for additional information Surface mount reference 4"(102 mm) _ ��4"(102 mm) square box ��� � � �� � �� octagonal box ---- � � ---f--- � � --- 1-1/2"(38 mm) Flush mount reference,mount even with final minimum box depth surface,or with up to 1/4"(6.4 mm)maximum recess ---------------------------------------------- �2098-9737 Relay(mounts 4098-9822 Relay� � Standard ize Base Mountina ; � in base electrical box or (mounts in base � ; � � remotely) electrical box) � ; 4098-9832 Adapter Plate,reauired for mounting � � ; � 1/to surface mounted boxes and 4"sauare flush box � � ' i I � i � i i i � i i i � i i � ' � �- 4098 Series Base � � � � � , � � � , � � � , � � Relay Size: 2-1/2"X 1-1/2"X 1"(3.75 ' � 0 � � cubicinches)(64mmX38mmX25.4mm) ' ;` __ ______ ___ ; ----------------------------------------------------------------------------------� � 4098-9794 Sounder Base Mountina ; � - � ; � For 4098-9794 only,when using 4"square box flush mount,a single ; ; gang adapter plate(RACO No.787 or equal,by others)is required ; ; 4098-9832 Adapter Plate,repuired for mounting ; ; �to surface mounted boxes(mounts inverted) � � � � � � � � � � � 4098-9794 � � SounderBase � � � � � � � I , � � � � � 4098-9754 Multi-Sensor � � � � � i �.�r/ i NOTES: 1. Review wire size,wire count,box type,and whether a locally mounted relay is used before determining box size. 2. When a locally mounted relay is used,mount relay in electrical box and use 1-1/2"extension ring(by others)on 4"square or octagonal box of 1-1/2"or 2-1/8"depth as required. 3. Flush mounting also fits a single gang box,2-1/8"(51 mm)deep if compatible with wiring requirements.(Not applicable if a locally mounted relay is used.) 4.Refer to Systems Manual 574-709 for additional information. 3 S4098-0024-8 11/2012 . . . TrueAlarm Multi-Sensor(ordered separately, refer to page 3 for mounting requirements) Model Description 4098-9754 Multi-sensor, photoelectric sensor with integral thermal sensor;select base from list below TrueAlarm Multi-Sensor Bases (ordered separately, refer to page 3 for mounting requirements) Model Description For More Detail See Data Sheet 4098-9792 Standard Sensor Base, no options 4098-9789 Sensor Base with connections for remote LED alarm indicator or unsupervised relay S4098-0019 4098-9791 Sensor Base with connections for Supervised Remote Relay and for remote LED alarm indicator or unsupervised relay 4098-9793 Isolator Base with built-in IDNet communications isolator, no options S4098-0025 4098-9794 Sounder Base with connections for remote LED alarm indicator or unsupervised relay S4098-0028 Accessories Reference (ordered separately as required, refer to page 3 for additional mounting requirements) Model Description 4098-9832 Adapter Plate,6-3/8"(162 mm)diameter, 1/4"(6.4 mm)deep, matches bases,see page 3 for required applications 2098-9808 Red LED Alarm Indicator on single gang stainless steel plate, mounts on single gang box, 1-1/2" Choose one (38 mm)minimum depth 4098-9822 if applicable Relay with operation that tracks base LED status, mounts in base electrical box,4"square or octagonal box with 1-1/2"(38 mm)extension ring, select box depth per actual wiring requirements Compatible with Supervised Relay, mounts remotely or in base electrical box; remote mounting requires 4" 2098-9737 4098-9791 only octagonal or 4"square box, 1-1/2"minimum depth; base mounting requires 4"octagonal box, 2-1/8"deep with 1-1/2"extension ring . - General Operating Specifications(refer to data sheet list for additional detail) Communications and Sensor Supervisory Power 4100ES,4100U,4010ES IDNet communications,24-40 VDC with data,400µA typical;supplied by control panel UL Listed Temperature Range 32° F to 100° F(0°C to 38°C) Operating Temperature Range 15° F to 122° F(-9°C to 50°C) Humidity Range 10 to 95% RH Smoke Sensor Sensitivity Range 0.2%to 3.7% per foot of smoke obscuration, selected at control panel(refer to additional information on page 2) Smoke Sensor Air Velocity Range 0-4000 ft/min (0-1220 m/min) Thermal Sensor Operation Fixed alarm temperature setting of 135° F(57.2° C), and/or rate-of-rise (selected at control panel) temperature alarm at 15° F(8.3° C)or 20° F(11.1°C),also selectable as utility monitoring operation from 32° F to 122° F(0°C to 50°C) Housing Color Frost White � 1 ' : • • • � • - 6-7/16"(164 mm) - I� 4-7/8"(124 mm)-�I --- � 0 2-1/4" (57 mm) 2-7/16" � 0� (62 mm) J LED status LED status indicator indicator � Sound output louvers extend Thermistor guard� Thermistor guard� from front and side Standard Size Base Mounting Sounder Base Mounting TYCQ SLMPLEX,and the product names listed in this materral a��e mnrks and/or registered marks.Unaud{xorized use is strictly prohihited.NFPA 72 and National Fire Alarm and Signaling Code are b�ademarks of the Natioraal Fire Protection Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0024-8 11/2012 www.simplexgrinnell.com OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Dual Address Bases for Multi-Sensor MEA (NYC) Acceptance* 4098-9754, Standard and Sounder � TrueAlarm photoelectric sensing and TrueAlarm thermal sensing combined in one housing: • TrueAlarm photoelectric technology accurately —, monitors for smoke activiry • TrueAlarm thermal sensing accurately monitars for , fixed temperature and rate-of-rise temperature, selected �_ or combined as required per sensor ~~� • Basic operation is UL listed to Standard 268 TrueAlarm Multi-Sensor 4098-9754 Mounted in • Sounder operation is also listed to UL Standard 464 as Multi-Sensor Sounder Base 4098-9795 an audible notification appliance Multi-Sensor Standard Base 4098-9796 provides: • Two sequentially addressed points,automatically .� assigned with one address selection • Connections for remote LED or LED tracking relay for � remote alarm status indication Multi-Sensor Sounder Base 4098-9795 provides - r the features of 4098-9796 and also provides: r, • Built-in piezoelectric sounder with high output (88 dBA)and low current requirements(20 mA) TrueAlarm Multi-Sensor 4098-9754 Mounted in • Sounder power can be from 24 VDC or from a Multi-Sensor Base 4098-9796 compatible Notification Appliance Circuit(NAC) - � . � - . . • Sounder output can be synchronized via communications or by the NAC,if NAC powered** TrueAlarm multi-sensor 4098-9754 combines the • Sounder operation can be independently activated from established performances of a TrueAlarm photoelectric the host control panel smoke sensor with a fast-acting and accurate TrueAlarm TrueAlarm analog sensing operation. thermal sensor to provide both features in a single • Analog sensor information is digitally communicated to sensor/base assembly. the control panel via lDNet or MAPNET II two-wire Digital Communication of Analog Sensing. communications Analog information from each sensor is digitally • Individual sensor information is processed by the host communicated to the control panel where it is analyzed. control panel to determine sensor status Photoelectric sensor input is stored and tracked as an For use with the following Simplex°products: average value with an alarm or abnormal condition being • Model Series 4008,4010,4100ES,4010ES,and 4100U determined by comparing the sensor's present value fire alarm control panels against its average value. Thermal data is processed to • Note:4008 Series fire alarm control panels provide a look for absolute or rate-of-rise temperature as desired. reduced feature set,refer to data sheet 54008-0001 Intelligent Data Evaluation.Monitoring each • Legacy models 4020/4100/4120 Series fire alarm photoelectric sensar's average value provides a software control panels,and Universal Transponders equipped filtering process that compensates for environmental for MAPNET II operation factors(dust,dirt,etc.)and component aging,providing • For use with 4100ES,4100U,or 401 OES control panels, an accurate reference for evaluating new activity. The multi-sensor 4098-9754 is also available using single result is a si�nificant reduction in the probability of false address bases;refer to data sheet 54098-0024 for more or nuisance alanns caused by shifts in sensitivity,either information,including TrueSense early fire detection up or down. operation combining photo and heat inputs ' l7tis product has bcen ap�xoved by the Califorrtia State Fre N�rsF�al(CSFN�pursuarrt to Functional and architecturally styled enclosures Sedion13144.1oftheCalifaniaH�IthandSafetyCode.SeeCSFMListing are for ceilin OI'WaII PT10UIltl11 : ��4��217faallw�ablevaluesar�d/aoonditia�scorioerningrrateri�presentedinthis 9 J doaarr�it.It is subject to ree�rination,revision,and possible car�cellation.F�ted for • Smoke sensor louver design directs air flow to chamber, use—�1tYofNewYaicDepartrrentofBuildings—NEP3S93EPr1ditionallistingsrraybe enhancing smoke capture appicar�e;contactyourlocalSirrpleacproductsupplierfathelateststatus.Listingsand ap�xovals urxler Slrrplex Tirre Recorder Co.are the property of Tyoo Fre Protedion • Sound louvers on sounder base exit both front and side aoduas. for high output sound *"Total quarrtity of saxxler l�ases available fa ooding on the sarr�corrrrunicatia�s d�anrid • Built-in magnetic test feature alarms both addresses �"�'�thpane�applicationarxlavailabilityofNACpa,ner.Refertospeaficoortrd par�requirerr�errts. • Designed for EMI compatibility • Optional accessories include remote alarm LED indicator or alarm LED tracking relay S4098-0033-5 9/2012 ■ - � • • '• • Control Panel Selection.Peak activity per sensor is TrueAlarm heat sensors monitor a fast reacting thermistor stored to assist in evaluating specific locations. The alarm providing operation that is self-restoring and rate set point for each TrueAlarm sensor is determined at the compensated. Due to its small thermal mass,the sensor control panel,selectable as more or less sensitive as the accurately and quickly measures the local temperature far individual application requires. analysis at the fire alarm control panel. The control panel Timed/Multi-Stage Selection.Alarm set points can be allows alarm selecrion to be per sensor as fixed programmed for timed automatic sensitivity selection temperature,or rate-of-rise temperature,or the (such as more sensitive at night,less sensitive during combination of both. day). Control panel programming can also provide Rate-of-rise temperature detection is selectable at the mulri-stage operation per sensor.For example,a 0.2% control panel for either 15°F(8.3°C)or 20°F(11.1° C) level may cause a warning to prompt investigation while a per minute. Fixed temperature sensing is independent of 2.5%level may initiate an alarm. rate-of-rise sensing and selectable to operate at 135°F Sensor Alarm and Trouble LED Indication.Each (57.2°C)or ]55°F(68°C).In a slow developing fire,the sensor base's LED pulses to indicate communications teinperature may not increase rapidly enough to operate with the panel.If the con�rol panel determines that a the rate-of-rise feature. However,an alarm will be sensor is in alarm, or that it is dirty ar has some other rype initiated when the temperature reaches its selected fixed of trouble,the details are annunciated at the control panel temperature setting. and that sensor base's LED will be turned on steadily. TrueAlann heat sensors can be programmed as a utility During a system alarm,the control panel will control the device to monitor for temperature extremes in the range LEDs such that an LED indicating a trouble will return to from 32°F to 122°F(0° C to 50°C).This feature can pulsing to help identify the alarmed sensors. provide freeze warnings or alert to HVAC system . , , , � � � problems. (Refer to specific panels for availabiliry.) � . • . Sealed against rear air flow entry Electronics are EMI/RFI shielded Sensor locations should be determined after careful consideration of the physical layout and contents of the Smoke sensing: area to be protected.Refer to NFPA 72,the National Fire • Photoelectric sensing technology Alarm and Signaling Code. On smooth ceilings, smoke • 360°smoke entry for optimum response sensor spacing of 30 ft(9.1 �n)may be used as a guide. • Chamber screen provides protecrion froin dirt,dust, For detailed application information,refer to 4098 and insects Detectors, Sensors, and Bases Application Manual, Part Number 574-709. Heat sensing: • Fast response thermistor design - • � . • Rate compensated, self-resetting operarion • Control panel can select per sensor for fixed I�� sa/�s°(�sa mm) - temperature sensing,rate-of-rise temperature sensing, or the combination of both . . - . - - 2-7/16" � TrueAlarm photoelectric sensors use a stable,pulsed (sz mm) infrared LED light source and a silicon photodiode �E�status � indicator receiver to provide consistent and accurate low power . --- , smoke sensing. Seven levels of sensitivity are available Sound output louvers extend for each individual sensor,ranging from 0.2%to 3.7%per from front and side foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. Multi-Sensor with 4098-9795 Multi-Sensor Sounder Base The sensor head design provides 360° smoke entry for i . 4-7/8"(124 mm)�i optimum smoke response.Because of the photoelectric � sensing technology,the 4098-9754 sensor is UL listed for air velociry of up to 4000 ft/min.However,care must be � o 2-1/4" taken in determining sensor locations to avoid areas �s��„m� where local airflow may also impact any smoke flow. % LED status (Refer to the application reference section on this page.) indicator Multi-Sensor with 4098-9796 Multi-Sensor Base 2 S4098-0033-5 9/2012 . � . . • • Base mounted address selection allows the • Sensitivity monitoring that satisfies NFPA 72 addresses of the multi-sensor base to remain with its sensitiviry testing requirements programmed location when the sensor is removed for . Peak value logging allows accurate analysis for service. sensitivity selection Integral red LED indicates power-on by pulsing,or • Automatic,once per minute individual sensor alarm or trouble when steady on,reflecting status of either calibration check verifies sensor integrity sensor. The exact status of the specific sensing element is • Multi-stage alarm operation annunciated at the fire alarm control panel. • Selectable alarm verification . � • Ability to correlate sensitivity selection with . . temperature • Individual smoke sensitivity and temperature • Automatic environmental compensation operation is selectable for each sensor • Smoke sensitivity displayed in percent per foot • Ability to display and print detailed sensar information in plain English language . . Electrical boxes are supplied by others,refer to notes below for additional information Surface mount reference 4"(102 mm) ��4"(102 mm) square box � � � � octagonal box \ + / 1-1/2"(38 mm) Flush mount reference,mount even with final minimum box depth surface,or with up to 1/4"(6.4 mm)maximum recess ; ; � 4098-9796 Multi-Sensor Base Mountina � , Outional 4098-9822 Relav , , � (Mounts in base electrical box and requires ; � 4098-9832 Adapter Plate,required for mounting � � additional volume,see notes 1 and 2 below) ; � /to surface mounted boxes and 4"spuare flush box � � ' � i � � � , � � � , � ; Relay size: ' � 4098-9796 Multi-Sensor Base ' ; 2-1/2"X 1-1/2"X 1" � � ; ; (64 mm X 38 mm X 25.4 mm) ; � ; � (3.75 cubic inches) ; � � � � � ; � ' �---------------------------------------------' ---------------------------------------------------------------------------------� � 4098-9795 Multi-Sensor Sounder Base Mountina � � - � ; p For 4098-9795 only,when using 4"square box flush mount,a single ; ; gang adapter plate(RACO No.787 or equal,by others)is required ; ; /4098-9832 Adapter Plate,required for mounting ; ; �/ to surface mounted boxes(mounts inverted) � � ► , � � � � � � � � � � ; 4098-9795 � � O Multi-Sensor � � SounderBase � i i i i i i i i � 4098-9754 Multi-Sensor � � � � � „ � � � � � ------------------� NOTES: 1. Review wire size,wire count, box type,and whether 4098-9822 relay is used before determining box size. 2. When 4098-9822 relay is used, mount relay in electrical box and use 1-1/2"extension ring(by others)on 4"square or octagonal box of 1-1/2"or 2-1/8"depth as required. 3. Flush mounting also fits a single gang box,2-1/8"(51 mm)deep if compatible with wiring requirements. (Not applicable if 4098-9822 relay is used.) 4. Refer to Installation Instructions 574-707 for additional information. 3 S4098-0033-5 9/2012 . . . TrueAlarm Multi-SensoP(ordered separately, refer to page 3 for mounting requirements) Model Description 4098-9754 Multi-sensor, photoelectric sensor with integral thermal sensor,for use with bases 4098-9795 and 4098-9796 TrueAlarm Multi-Sensor Bases (ordered separately, refer to page 3 for mounting requirements) Model Description 4098-9795 Sounder Base Dual address base for multi-sensor 4098-9754;with connections for remote LED alarm 4098-9796 Standard Base �ndicator or unsupervised relay Accessories (ordered separately as required, refer to page 3 for additional mounting requirements) Model Description 4098-9832 Adapter Plate,6-3/8"(162 mm)diameter, 1/4"(6.4 mm)deep, matches bases, required for some mounting combinations 2098-9808 Red LED Alarm Indicator on single gang stainless steel plate, mounts on single gang box, Choose 1-1/2"minimum depth one if 4098-9822 required Relay with operation that tracks base LED status, mounts in base electrical box,4"square or octagonal box with 1-1/2"(38 mm)extension ring,select box depth per actual wiring requirements . - . • General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications,auto-select,24-40 VDC w/data,400µA typical, supplied by control panel,2 addresses per base Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG Current 1 mA typical supplied from communications, no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32°F to 100°F(0°C to 38°C) Operating Temperature Range 15°F to 122°F(-9°C to 50°C) Humidity Range 10 to 95%RH Smoke Sensor Sensitivity Range 0.2%to 3.7%per foot of smoke obscuration,selectable at host control panel Smoke Sensor Air Velocity Range 0-4000 ft/min(0-1220 m/min) Thermal Sensor Operation Fixed alarm temperature setting of 135°F(57.2°C),and/or rate-of-rise temperature (selected at host control panel) alarm at 15°F(8.3°C)or 20°F(11.1°C),also selectable as utility monitoring operation from 32°F to 122°F(0°C to 50°C),availability is panel dependent Sensor,Bases,and Adapter Plate Color Frost White Sounder Operation with 4098-9795 Multi-Sensor Sounder Base Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(sounder on) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC Sounder Output 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Appliances and UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel (selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision NAC Powered Operation When sounder is activated by control panel,sounder output tracks connected NAC to allow synchronized coding(Temporal or March Time,etc.) 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(connects to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base TYCQ SIMPLEX,and the product names listed in this rnateria!are marlcs and/m�registered mark.r.Unauthorized use is strictly proh�ibited.NFPA 72 is a eegistered trademarlc of the Nafional Fire Pr�otectron Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0033-5 9/2012 www.simplexgrinnell.com OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control � x I�I • �, x o ,,, Compact air duct sensor housing with clear , _ cover to monitor for the presence of smoke** �, ��e,,, 0000000 Includes factory installed TrueAlarm �o o�0000� '�a photoelectric smoke sensor and features: o o��000 o," ,�� o � n[ia. • Individual sensor information processed by the host __ o o �„�, control panel to determine sensor status � � � °�; x „ -.—, • Digital transmission of analog sensor values via IDNet or MAPNET II,2-wire communications � �1 �• Programmable sensitivity,consistent accuracy, \ environmental compensation, status testing,and o�� monitoring of sensor dirt accumulation Model 4098-9755: • Basic duct sensor housing(no relay output)powered by IDNet/MAPNET II communications Duct Sensor Housing, Front and Bottom View Model 4098-9756: • Duct sensor housing with supervised output for � � multiple remote relays;requires separate 24 VDC; ��M ��� includes one relay oa,�� s�mw� • Relay output is under panel control °�ma°� m � • At the panel,relay output can be activated manually or � in response to a separate alarm or other input 2098-9808 2098-9806 General features: Remote Status/Alarm Indicator and Test Station • UL listed to Standard 268A . . . • Clear cover allows visual inspection � OperatiOn.Simplex compact air duct smoke sensar • Test ports provide functional smolce testing access housings provide TrueAlarm operation for the detection of with cover in place smoke in air conditioning or ventilating ducts. Sampling • Mounts to rectangular ducts or round ducts;minimum tubes are installed into the duct allowing air to be directed to size is 8"(203 mm)square or 18"(457 mm)diameter the smoke sensor mounted in the housing. • Magnetic test feature for alarm initiation at housing - . . � . - , . • Optional weatherproof enclosure is available Digital Communication of Analog Sensing. separately(refer to data sheet 54098-0032) Analog infonnation from tbe sensor is digitally DiagnoStiC LEDS (on interfaCe board): communicated to the control panel where it is analyzed. • Red Alarin/Trouble LED for sensor status and Sensor input is stored and tracked as an average value communications polling display with an alarm or abnormal condition being determined by • Yellow LED for open or shorted trouble indication of comparing the sensor's present value against its average. supervised relay control(4098-9756 only) Intelligent Data Evaluation.Monitoring each Sampling tubes (ordered separately): photoelectric sensor's average value provides a software filtering process that compensates for environmental • Available in multiple lengths to match duct size factors(dust,dirt,etc.)and component aging,providing • Installed and serviced with housing in place an accurate reference for evaluating new activity. The Remote module options (ordered separately): result is a significant reduction in the probability of false • Remote red status/alarm LED(2098-9808) ar nuisance alarms caused by shifts in sensitivity,either up or down. • Remote test station with LED(2098-9806) • 4098-9843 remote relays(refer to page 2 for details) � ���e that smoke detedion in air ducts is ir�erxled to provide notification of the presence of srrnke in the duct.It is not i�tended ` These products have been approved by the C�ifartia State Fre N�rslx�l(�purs�.kant to to,and will not,replace srra{ce detedion requirements for open Sedion 13144.1 of the Califania H�th and SaFety Code.See CSFM Listing 3240-002G.241 fa allava�le v�ues arxUor conditions oor�ceming material presented in this docurrerrt.It is ������dU(�2�IC�101'1S. subjed to re-e�nination,revision,arxi possible car�lation.Accepted for use—Qry of New Yaic Department of Buildings—NEP3.rr93E.Prlditional listings rray be applic�le;mrrtact your loc�55rrplex product supplier for the latest status.Listirx�s and approvals urxier Sirrplex Tirm Recorder Co.are the�xoperty of Tyco Fre Protedion Produds. S4098-0030-9 11/2012 - � • • � - • � �• • • - • • '• Control Panel Selection.Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations. The alarm settings(such as 2.5%per foot obscuration)due to the set point for each sensor is determined at the control ducts being a relative dirry environment. However,the panel, selectable as tbe individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED.Each sensor housing's red status av oilable for each individual sensor,ranging from 02%to LED(located on the electrical interface board)pulses to 3.7/o per foot of smoke obscuration. Sensitivity is indicate communications with the panel.If the control selected and monitored at the fire alarm conYrol panel. panel determines that a sensor is in alarm,or that it is - � . . - dirty or has some other type of trouble,the details are annunciated at the control panel and that sensor housing's • Individual smoke sensirivity seleckion status LED will be turned on steadily.During a system • Sensitivity monitoring that satisfies NFPA 72 alarm,the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help . Peak value logging allows accurate analysis for identify any alarmed sensors. (Remote Status/Alarm sensitivity selecrion LEDs track the operation of the sensor housing LED.) • Automatic, once per minute individual sensor ' • • - - • calibration check verifies sensor integrity TrueAlarm photoelectric sensors use a stable,pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power . Ability to display and print detailed sensor smoke sensing. information in plain English language • Relays of mode14098-9756 are under panel control � � � for ON, OFF,or override Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing;operating power is supplied by Simplex fire alarm control panel models:4100ES, 4098-9755 either IDNet or MAPNET II communications(no relay 4010ES,4008,4010,4100U,and legacy products output) 4020,4100/4100+,and 4120.Also 2120 CDT if configured for MAPNET II,TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator on single-gang stainless steel plate 4098-9755 Use single gang box, Test Station with keyswitch and red LED status indicator,on 3"H x 2"W x 2"D 2098-9806 single-gang stainless steel plate; (turning switch to"TEST" 4098-9756 �76 mm x 51 mm x 51 mm) initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay;single Form C(7 A@ 120 VAC); refer to pages 3 and 4 Locate relays within 3 ft 4098-9843 for additional relay information;one included with 4098-9756; 4098-9756 only; (1 m)of device being wiring is 18 AWG(0.82 mm2)color coded wire leads connect up to 15 controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kS2, 1/2 W; (ref.733-894); 4098-9756 At last relay location required to supervise remote relay coil connection `Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube.A correctly sized sampling tube(ordered per application)is required,refer to chart below. • • • - • • • - - • - • . � • • Overall Duct Width Tube Required Suggested Cut Length 12"(305 mm) 4098-9854 1/2"(12.7 mm)longer than duct width 13"to 23"(330 mm to 584 mm) 4098-9855 1/2"(12.7 mm)longer than duct width 24"to 46"(610 mm to 1168 mm) 4098-9856 3 in"(76 mm)longer than duct width 46"to 71"(1168 mm to 1803 mm) 4098-9857 3 in"(76 mm)longer than duct width 71"to 95"(1803 mm to 2413 mm) 4098-9858 3 in"(76 mm)longer than duct width 2 S4098-0030-9 11/2012 � • • � � - NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. 11-3/8"(289 mm) Exhaust tube access hole � Conduit(by others) � � x 4098-9714 Smoke sensor,mounted in special interface base(supplied) i ��Metal plate with dual holes 6-3/4" (171 mm) • �� for 3/4"(19 mm)conduit,plug �•. ��, - ""' supplied for unused hole °0000000 ��° 0 0 000o Q 1 � 0 0 0 0 OOCJ CIO Yellow LED,relay control trouble indicator(4098-9756 only) Sampling tube � � 0 access hole � o 0 0 Red sensor � �� status LED Side of duct u o0 x • x o "-- -' o Wiring terminals Stationary baffle(built-in) Captive fastening screws(4) Ma netic test area NOTE:Orientation shown is for reference Transparent cover Gasketed sensor area only,refer to General Location Notes and End View illustration below for alternate � mounting reference. 3-3/8" ;� n'���� �I �� �'�� ������-� (86 mm) ■ : . . b�� Duct wall z � 13/16" (21 mm) Exhaust tube 4098-9843 Remote Relay (supplied) (7 A@ 120 VAC,for use with 4098-9756 only) Test ports(2)provided NOTE: Mount in separate electrical box within Sampling tube,ordered Gaskets su lied 3 ft(1 m)of device being controlled per for measuring airflow separatel � pp � y per duct width NFPA 72 and for aerosol injection 1-3/16" (30 mm) 1-1/2„ \ 13/16„ Square duct Alternate location (38 mm) �� �(21 mm) reference outline (if appropriate) � �� 18"Round duct outline (minimum diameter) Sampling tube,keyed for proper hole alignment with holes facing into airflow(template is provided for proper tube installation). (Housing is shown as position 2 per note 2 below.) - -----------� General Location Notes: • • ' • • 1.Testing performed under the auspices of the Fire Detection , Institute(FDI)recommended when sampling tubes are not � located vertically,that they be positioned horizontally in the Duct � � upper half of the duct to account for possible stratifcation. housing � � � �. 2.Three duct side mounting options are available as shown below. � Mount housing at 90°to airflow for all orientations. / � ' Arrows indicate allowed airflow directions. T � - ----------=- �, I ' � � ��, �z; � � �3 ���i°o�vi�i Exhausttube P '�� � _ 8"Square duct outline � — � ' � �' d (minimum width) � _v� � ` _ � � [ y' . �J�., r� . I ------------ ------------ '8 DO NOT MOUNT ON BOTTOM OF DUCT / \ 3 S4098-0030-9 11/2012 � . . . . Duct Sensor Location Considerations: 1. Proper duct smoke detection location must ensure �EXnaust�amper �ser,sor oK adequate airflow within the duct housing. 2. Duct air velocity rating is 300 to�4000 ft/min(91 to Exnaust f � �—Return air 1220 m/min).Pressure differential between intake and exhaust tubes is required to be between 0.015 to �o not iocate ; 1.55 inches of water(0.381 to 39.37 mm). sensor here 3. Ensure accessibility for test and service. Return air damper 4. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts,ahead of mixing areas; upstream of air h�unidifier and cooling coil. 5. Other locations and orientations may be required for Fresh air� '; � Supply Air proper duct smoke detection depending on duct ' access, system design,and duct airflow testing. �Jnot iocate Filter ba k �sensor oK Contact your local Simplex product supplier for sensor here 75S15tflriCe. Locations to Avoid: Additional Information.Refer to NFPA 90A,Standard 1. Where dampers closed for comfort control would for the Installation of Air Conditioning and T�entilating interfere with airflow. Systems;NFPA 72,the National Fire Alarm and Signaling 2, Next to outside air inlets(unless the intent is to Code;and the NEMA Guide for Proper Use of Smoke monitor smoke entry from that area). Detectors in DuctApplications,and Installation Instructions 3. In return air damper branch ducts and mixing areas 574-776. where airflow may be restricted. • - , . General Mechanical and Environmental Air Velocity Range(linear fUmin) 300 to 4000 ft/min(91 to 1220 m/min) Sensor Sensitivity Range 0.2%to 3.7%per foot of obscuration,selectable at host control panel UL Listed Temperature Range 32° F to 100° F(0°C to 38°C) Operating Temperature Range 32° F to 122° F(0°C to 50°C) Storage Temperature Range 0° F to 140° F(-18° C to 60° C) Humidity Range 10%to 95%RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG(0.82 mm2 to 3.31 mmz) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current(2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current(2098-9806) Remote Alarm LED and Test Station Distance 250 ft(76 m)maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select,one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control,Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC(24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current 15 mA @ 24 VDC;add 15 mA for each 4098-9843 relay For use with 4098-9843 relay only,quantity of 15 maximum;distance of 500 ft Supervised Remote Relay Control Output (152 m)maximum; requires 4081-9008(ref.733-894) 10 kS2, 1/2 W end-of-line resistor 4098-9843 Relay Output Ratings,Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC&120 VAC;250µA @ 5 VDC Location Distance 500 ft(152 m)maximum to relay coils; locate relays within 3 ft(1 m)of device being controlled per NFPA 72 TYCO,SIMPLEX,anr/the product narnes listed in Chis material are markr and/or r�egistered marks.Unauthorized use ds strictly prohibited.NFPA 72 and Nationa/Fire Alar»z and Signaling Code ar�e registered tradernar-ks oJ�the National Flr�e Protecfion Association(NFPA). �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0030-9 11/2012 www.simplexgrinnell.com OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice. �oSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; FMApproved; IDNetT"" and MAPNET II° Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (IAMs) � � IDNet or MAPNET II addressable communications � supply both data and power over a single wire pair s��15!!?'�plex to provide'`*: qo90 soo� �� su��RUis�o ia� C� • Supervised Class B monitoring of normally open,dry i�s�.iNSrR.5�4-331 DpTE CODE: contacts M ? ,I„E,I�. �.ome N- 3 • Total wiring distance from IAM to supervision resistor(s)of up to 500$(152 m) � �00 p� • Monitored connecrion is compatible with Simplex° 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised IAM • For use in indoor locarions up to 158°F(70° C)such as (shown approximately 3/4 size) attic spaces or similar applications For use with following Simplex control panels: • Model Series 4008,4010,4010ES,4100U and 4100ES fire alarm control panels for IDNet communications • Model Series 4100/4100U/4100ES,4120,4020,and 2120 Communicating Device Transponders(CDTs) equipped with MAPNET II communicarions Model 4090-9001: • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box �� "sTE° SIGNq�INGOEVICE ISSUE NO • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation(requires mounting bracket, 4090-9051 Supervised IAM (shown approximately 3/4 size) ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high � . � � humidity(LED is not present on this model) • Color coded 18 AWG leads for wiring Individual addressable modules (IAMs) receive IDNet communications provides current limited both power and communications from a two-wire monitoring: MAPNET II or IDNet circuit. They provide location • Provides monitaring of tamper switch(supervisory) specific addressability to a single initiating device(such and waterflow switch(alann)on same circuit using as single station smoke detector alarm contacts ar heat detector contacts)or multiple devices at the same location one point by monitoring normally open dry contacts and the wiring • Available with IDNet communications only to an end-of-line resistar. Multiple operation modes are available and are selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic • Contact closure status can be tracked housing and provides screw terminal connections and a status indicating LED. • Momentary contact closure conditions can be selected at the panel to be latched ar tracked(not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads. It does not provide a status indicating LED. UL listed to Standard 864 ` These products have been approvetl by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this tlocument.It is subject to re-examination,revision,antl possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35-93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4090-0001-10 • • - . • - � • • - • � • • • Contact Closure. Closure ofthe monitored contact(s) For use with IDNet communications only,these initiates an alarm or other response as programmed at the IAMs can provide quad-state sensing of normal,open fire alarm control panel. An open in the monitored circuit circuit, short circuit,and current limited conditions. wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line Panel SeleCtions. Selections can be made at the control and current limiting resistors, dual functions such as panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be device contacts are momentary, such as from a determined and communicated by a single addressable rate-of-rise heat detector,or to track the device contact point. status(not available with the 2120 CDT). � . • . Model Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals;see applicable options below 4090-9051 Supervised IAM,encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws;galvanized steel 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kS2, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kS2, 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 kS2, 1/2 W . - . . Electrical Power and Communications MAPNET II or IDNet,auto selected, 1 address per IAM Input Requirements Normally open,dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections (0.82 mm to 2.08 mm ) 4090-9051 Color coded wire leads, 18 AWG(0.82 mmZ),8"long(203 mm) Installation Instructions 574-331 for 4090-9001; 579-572 for 4090-9151 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances 500 ft(152 m)maximum without protectors Distance from IAM to Contacts 400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Mechanical 4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm) Dimensions 4090-9051 1-9/16"W x 1-9/16" H x 9/16" D(40 mm x 40 mm x 14 mm) Housing Material,4090-9001 Black thermoplastic Encapsulation Material,4090-9051 Epoxy, beige Temperature Range 32°to 158° F(0°to 70°C); intended for indoor operation Humidity Range Up to 93% RH at 100° F(38°C) 2 S4090-0001-10 . . . . � � 4090-9001 IDNet Field wiring shown supervised IAM for reference m � S��EX iINE�. 4�90-9001 suv�uis�o iau xsi.ixsiw.s�e s�i opiE cooE. LED viewing port M��o�Er ��.q u o0 000 � Single gang electrical � box 2-1/2"(64mm) minimum depth (supplied by others) Address setting under resealable label � � Single gang blank cover plate and mounting screws,for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate O O ! O ° Light pipe for � LED viewing � 4-1/4" O O 4-1/2" (108 mm) (114 mm) �� .� � �. Er ';� , i���r� 16F v,_5�<1�`:: � , 0 0 ° O 2-1/2" �(723m1m) (64 mm) 4090-9806,Trim plate for 4090-9807,Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-10 � 1 • 1 ' 1 • • • • Address setting is � � at rear of housing 4090-9051 Encapsulated Supervised IAM � �� � Single gang electrical box 2-1/2"(64mm) minimum depth (supplied by others) � Single gang blank cover plate and mounting screws (supplied by others) Tyco is a registered tradeniar-k of�Tyco lnter�nntional Services GmbN and is used under license.Simplex,Xhe Simplcr[ogo,IDNet,and MAPNFT/I are trademarks of Tyco Lnternutional L[d.and its affiliates and are used zuader license. �3S i m p I Ex SimplexGrinnell LP Westminster• Westminster,MA•01441-0001•USA S4090-0001-10 o www.simplexgrinnell.com OO 2011 Tyro.A!!righGr r�eserved.All s�eciftcalions and other•ir formation shown were curr�ent as o/document revision da[e and are si{bject[o change without notice. ��SimplEx Multi-Application Peripherals UL, ULC Listed; FM, CSFM, IDNet Communicating Devices and MEA (NYC) Approved* Model 4090-9002 Relay IAM � Individual Addressable Relay Module (Relay � o � o � IAM): • IDNet addressable control for use with Simplex°fire � � � alarm control panel models 4100ES/4100U,4010ES, 4008, and 4010 � � � • A single addressable point provides control and status � 4�mwex � tracking of a Form"C"contact � ,., `�O • Low power latching relay design allows IDNet p � ;�r.=�; ` � p h � F communications to supply both data and module power 'r°°°°°°°° Compact, sealed construction: � o o � • Enclosed design minimizes dust infiltration • Mounts in standard 4"(102 mm)square electrical box • Screw terminals for wiring connections 4090-9002 IDNet Relay IAM Package (shown approximately 1/2 size) • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be ' ' ' viewed after installation UL listed to Standard 864 Communications IDNet communications, 1 address per device � _ � � Relay IAM Power Supplied by IDNet communications Contact Ratings*(not rated for incandescent switching) IDNet Relay IAMs allow fire alarm control panels to control a remotely located Form"C"contact using IDNet Type Form C, SPDT addressable communications for both data and module 2 A@ 24 VDC, resistive from listed power. Typical applications would be for switching local Power-Limited fire alarm power for control functions such as elevator capture,or 1 A@ 24 VDC, inductive supply control of HVAC components,pressurization fans, Nonpower-Limited 0.5 A@ 120 VAC, resistive dampers, etc.Relay status is also communicated requiring * Provide circuit fusing and transient suppression as only one device address. required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC • � � , networks or varistors,depending on device type. Refer to Installation Instructions 574-184 for additional information. Model Description Screw terminals for in/out wiring, 4090-9002 Relay IAM Wire Connections 18 to 14 AWG wire(0.82 to 2.08 mmZ) Optional Trim Plates Up to 2500 ft(762 m)from control panel Model Description IDNet Up to 10,000 ft(3048 m)total wiring For semi-flush Communications distance includin T-Ta s 4090-9801 Trim plate,galvanized Wiring Reference � g p � mounted box steel,with LED viewing Compatible with Simplex 2081-9044 For surface window; includes Overvoltage Protectors 4090-9802 mounted box mounting screws Dimensions 4'/e'H x 4'/8"W x 1 '/8'D (105mmx105mmx35mm) ' Thisproducthasbeenap�xovedbytheCalifomiaStateFreN}arshal(CSFN�pursuar�to Housing Material Blackthermoplastic Section 13144.1 of the Califomia Health and Safety Code.See CSFM Listing 73040026:223forallanral�levaluesarxVoroonditiais�iingmateri�presc-��tedinthis Mounting Plate Sheet metal,galvanized doa�rr�,t.itissubjecttore-e�rinatia,,revision,andpossiblecancellation.P�eptedfor Temperature 32°to 120° F(0°to 49°C), �-a�y o�r�w vor�o�trr�r,t o�aU�ia��-�a3.��E.a�d�t�o�,�r�r,��y r� applical�le;cont2dya,rl«:alSlrrplexprodudsupplierforthelateststatus.Listingsand Range intendedforindooroperation appr�ralsur,de�-SirrpexTimeReoorcic�-Co.aretneprq�ertyofTyoosafetyProduas Humidity Range Up to 93°/u RH at 100° F(38°C) V�kstrririster. S4090-0002-8 12/2012 � . . . . � �O 0 � 0 Address setting under � � resealable label 0 �� � O O �N0�w � ,�w �" .� � m 4"(102 mm)square box,2-1/8" �// (54 mm)minimum depth, RACO � 232 or equal(supplied by others) 4090-9002 Relay IAM .� �/ �� Double gang blank cover plate and mounting screws,for ' use when LED is not required to be externally viewed �' (supplied by others) Mounting Reference, Double Gang Blank Cover Plate 0 � � � Light pipe for LED viewing 4-9/16" 4-5/16" � � (116 mm) DISCONNECT POViE6� GGONNECT�" �F � (109 mm) CE�OdE C'R'd'�CIVG ,:i �,; � � � 0 -9/16"(116 mm)� �-4-5/16"(109 mm)� I 4090-9801,Trim plate for 4090-9802,Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO,SIMPLEX,and the product names[isted rrz khis material are marks arad/or registered marks.Clnauthorized use is sU�ictly pr�ohibited. �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4090-0002-8 11/2012 www.simplexgrinnell.com �2012 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice. �oSimplEx LifeAlarm Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control from 4010, 4010ES, MEA (NYC)Acceptance* 4100ES/4100U IDNet Communications, or Conventional NACs � Provides additional notification appliance circuit � � (NAC) capacity with flexible operation modes and power-limited design up to s Nacs Four, Class B NACs are standard: � � • Rated 2 A each for conventional reverse polarity aoos i�Net 24 VDC notification appliances and providing NAC Extender - - - - multiple operation modes ==_==_==__= � � • Can be selected to provide synchronization for Simplex°visible notification strobe flashes � • Capable of controlling TrueAlert non-addressable � optionai ioNet notification appliances operating with SmartSync =__________ Channe�Repeater two-wire control mode** ;-�-�--:� � � Input control options: � �� � � � � a , . � . -.� ; � `� �� • IDNet addressable communications from a Simplex 2_Wire IDNet �. ` � mode14010,4010ES,4100U,or 4100ES Fire Alarm Communications or ��� ��� ��. ContTOl Panel** ' Fiber Optic IDNet ``� • Or from one or two conventional 24 VDC NACs with � Communications or `� multiple output control options '. � NAC Control ������������������������������������������������������������ , � IDNet communications control benefits: -�_: • Provides status monitoring and individual NAC control IDNet Fiber � using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet"Device Level"earth fault location ������������������������������������������������������������ � . WALKTEST operation is available with either 4010(shown)or input choice 4010ES/4100ES/4100U — Internal 8 A power supply/battery charger: F�re Aiarm cor,troi Par,ei • Charges internal batteries up to 12.7 Ah or up to 18 Ah Fire Alarm control Panel with batteries in external cabinet conventional NACs • Provides status monitoring of battery,input power,and 4009 IDNet NAC Extender Connection Reference Drawing earth faults . . . • Rated 8 A for"Special Application"appliances; including Simplex 4901,4903,4904,and 4906 Series ADA ComplianCe. Complying with the notification horns,strobes,horn/strobes,and speaker/strobes requirements of ADA(Americans with Disabilities Act) • Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is Optional 4009 IDNet NAC Extender modules: available within the fire alarm control panel.When additiona]power is required,a Simplex 4009 IDNet NAC • IDNet Communications Repeater provides Class B or Extender can provide up to 8 A of NAC power with up to Class A output eight, supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility.The 4009 IDNet NAC Extender available as Class B or Class X can be mounted close to a compatible dedicated host • Four additional Class B NACs,rated l.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A,Two Circuit Adapter Module Additional Information.For addirional operarion detail UL Listed to Standard 864 and application information,refer to Installation � Instructions 574-181 and field wiring diagram 842-068. . IDNet communication fiber optic transmitters: ` u-cr�r�a��saoo�-�mzcam�sp�«��ar,��,��a�ytr�c��f«�a State Fre N}arsh�(CSFM)pursuaM to Sedion 13144.1 of the C�ifomia H�Ith arid • For applications requiring the data integrity available ��y�.����;,,����.21arara�ian�ev�uesar�orconditions with fiber optic communications corioerning rreterial presented in this document.It is subjed to ree�rrina[ion,�s�a,, and possible car�odlation.Po�pted fa use—Qty of NewYork Department of Buildings • Available as Class B or Class X _�p�,�93E.Pdd;t;a�al�;stinysnroybeappl;cable;oor�tactyax�ocalSirrpleacprod,�t • Mounts in standard six-gang electrical box supplie�'fa-thelateststatus.Listingsandapprovalsurxic-SirrpleacTirreReoorderCo. arethe propertyof SirrplexGrinrx�l LP,V�kstrrinster. External battery cabinet for 18 Ah batteries **4100Urequiresrevisionl1soflwareahigherfa-mrrpatibility.4010requiresrevision2 software a-hic�er fa-mrrpatibility. S4009-0002-11 1/2013 � • • • • • • - • • • IDNet Addressable Communications Compatible. Hardwire Control Applications. For applications Up to ten(10),4009 IDNet NAC Extenders can be where an existing(or new)conventional NAC needs controlled per 4010ES/4100ES/4100U IDNet additional power,the 4009 IDNet NAC Extender can be communications channel;up to five(5)can be controlled controlled directly from the NAC. Either one or two on tbe 4010 iDNet communications channel. Each output NACs,from either the same,or from different host fire NAC can be individually controlled for general alarm ar alarm control panels,can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for be manually controlled from the host panel. IDNet more detail.)Alarms from the host panel will activate the conYrolled extenders will inform the host panel of troubles four,4009 IDNet NAC Extender NACs(or optionally, via lDNet communications.4010ES/4100ES/4100U eight NACs)to extend the alarm. control panels control using multi-point rules,refer to The 4009 IDNet Extender monitors itself and each of its data sheet S4090-O011 for details. output NACs for trouble conditions, including earth Optional IDNet Repeaters.IDNet communications can faults.Extenders wired to conventional NACs will be repeated with the optional IDNet Repeater Module or indicate a trouble by opening the path to the NAC's with the optional Fiber Optic Receiver Module.Up to 100 end-of-line resistor,but retaining the ability to respond to of the IDNet channel points can be repeated once(refer to alarms. Individual troubles are also annunciated by LEDs pages 3 and 5 for details). Repeated IDNet communications located on the 4009 IDNet NAC Extender main circuit also support the"device level"earth fault location utility of board. (Refer to page 7 for more diagnostic information.) the host panel. . • . Standard Models Model Description 4009-9201 120 VAC input 4009-9202CA* 4009 IDNet NAC Extender with 4,Class B NACs and 8 A power supply 4009-9301 240 VAC input " ULC listed model Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power,Class B 4009-9808 Dual Class A adapter(for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater,output is Class A or Class B Select either an IDNet Repeater or a Fiber 4009-9810 Class B Optic Receiver as required;one transmitter 4009-9811 Fiber Optic Receiver Class A(IDNet), Class X(fiber) can connect to one receiver 4009-9805 Red Applique for door Select if required 2975-9801 Beige trim 1-7/16"wide(78 mm), use if required for Semi-Flush Trim Kit 2975-9802 Red trim semi-flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required,24 VDC operation 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet,two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090-9105 IDNet Fiber Optic Class B operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class X operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4"W x 13-1/2"H x 5-3/4"D (413 mm x 343 mm x 146 mm) 4081 Series End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details 2 S4009-0002-11 1/2013 • � • • • Typical IDNet compatible devices e (Refer to individual devices for actual wiring requirements,some wiring is not shown.) i � ■ �n� I IDNet addressable communications channel, pIfVIII�I��I101B0011111IfIIIItlVdtl�VOVBOVV��161111Vdl�lildllll �/shown Class B(Style 4) IfIIVIVI��II�IB01B!lIIVIIIIIVVVV9V�B9VVVVVI91111lVIVIII�UU Output NACs,four standard, Conventional NAC operation(horns) _ eight with expansion option � �= �—�Select conventional °��� °— or SmartSync 4100ES(shown) ==°== =-=== - �operation per NAC or 4010ES/4100U/4010 � � � Fire Alarm Control Panel � SmartSync operation(horns and strobes) 4009 IDNet NAC Extender with ====_=__==_ - optional internal IDNet Repeater Conventional NAC � � operation(strobes) Repeated IDNet Channel: ________°v up to 100 devices maximum on repeater output, � � � ��� 250 devices total on IDNet Channel ° ����'__����:� IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to ten (10)4009 IDNet NAC Extenders may be connected per 4010ES,4100ES or 4100U IDNet channel, up to five (5)on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). • • - • • . . Two fiber cables,3000 ft Output NACs 4090-9105,Class B (914 m)maximum distance =__________ (Style 4)Output Fiber °°°°°°°°°°° � � IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Optic Transmitter 0 � � _ _.�_... � � o IDNet addressable communications � � channel Class B(Style 4)or Class A (Style 6),Class B shown Repeated IDNet Channel:up to 100 devices maximum on repeater output,250 devices total on IDNet Channel IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Four fiber cables,3000 ft � 4010,4010ES, (914 m)maximum distance 4100ES,or 4100U Fire �I . . . . ___-__--__- Alarm Control Panel - 24 VDC power for/ =_°______=_ � fiber optic transmitters 4090-9107,Class A(Style 7) fl � � Output Fiber Optic Transmitter � �� °°°==°===°= � � 4009 IDNet NAC Extenders with optional Output NACs internal IDNet Fiber Receivers NOTE: Up to ten (10)4009 IDNet NAC Extenders may be connected per 4010ES, 4100ES or 4100U IDNet channel, up to five(5)on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one receiver in a 4009 IDNet NAC Extender. 3 S4009-0002-11 1/2013 . . . . . . . . . � . . . . NAC Input Selections. The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non-addressable operation. • Track input NAC operation or to provide a locally Non-addressable models are available with 2-wire generated code, selectable per NAC input SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet • If selected for local coding,NAC outputs can be either NAC Extender: Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender(input NACs must be on • TrueAlert non-addressable models with SmartSync continuous with Alarm) operation allow audible notification to be separately • Addirionally,NAC outputs can be selected to provide controlled over the same wire pair that controls visible the Simplex strobe synchronization signal. This signa] notificarion will synchronize the flashes of synchronized strobes but . 4009 IDNet NAC Extenders can be selected to provide will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs.) communications or conventional NACs NAC input to NAC output control can be selected for • iDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or SmartSync operation Conventional NAC Output Operation Options • With NAC input control, all output NACs are selected Input A B C for either conventional or SmartSync operation NAC 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 . Refer to data sheet 54009-0003 far TrueAlert NAC 2 NACs 3&4,7&8 NACs 5-8 None Addressable operation details,contact your local SmartSync NAC Output Operation Simplex product supplier for further information on Input NAC Control Function specific TrueAlert notification appliances NAC 1 Strobe Control NAC 2 Horn Control All NAC outputs(1-8) • • • � � • • � . • Up to eight(8)output NACs total;hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input � � (see Note 1) ,� Conventional NACs � = ========= - - - - � � � With hardwire control, � '°°� �'W' NAC outputs are all � m Output conventional or all ------ ----- - "''` ' ' "`� ' ' NACs SmartSync operation � ====°====== - � ___________ � 4009 IDNet NAC i � i Extender i � � � i Fire Alarm Control Panel i i � aaW� with Conventional NACs � � SmartSync operation i � �---------------------- --' i i Class A operation,either mode,requires NAC 2 input � 4009-9808 Dual Class A Adapter (optional,see Note 1) i � To additional 4009 IDNet NAC Extenders(up to four(4), `---------} 4009 IDNet NAC Extenders per NAC);see Note 2 Notes: 1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. NAC 1 is"on-until-reseY'and NAC 2 is"on-until-silenced." 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or, if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-11 1/2013 � 1 1 • � � • - • - • 120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz Input 240 VAC Input(4009-9301) 1.5A @ 204-264 VAC, 50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating $A, Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs 2 A each, Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each, Special Application appliances (requires 4009-9807) 1 A each, Regulated 24 DC appliance power Special Application Simplex 4901,4903,4904,and 4906 Series non-addressable horns, strobes, Output Ratings and combination horn/strobes and speaker/strobes(contact your Simplex Appliances product representative for compatible appliances) Regulated 24 DC Power for other UL listed appliances; use associated external synchronization Appliances modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized;output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA @ 24 VDC,system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 ft(762 m) IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed Module 250 per channel) (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m) Total distance including"T-taps"is 10,000 ft(3048 m) Class A loop maximum distance is 2500 ft(762 m), no"T"taps Fiber Optic Receiver Modules Input Current 4009-9810, Class B,65 mA @ 24 VDC, system supplied 4009-9811,Class X,80 mA @ 24 VDC,system supplied IDNet Output Specifications Same as those for Repeater Module(see above) Fiber Optic Transmission Distance 3000 ft(914 m)maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32°to 120° F(0°to 49°C) Operating Humidity Range 10%to 90%RH from 32° F to 104° F(0°C to 40°C) Wiring Connections" Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) � - • • • - • Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B,30 mA @ 24 VDC 4090-9107, Class X,35 mA @ 24 VDC Multimode,graded index, 50/125um,62.5/125�m, 100/40�m,or 200 um Fiber Optic Connections and cable Type ST connectors requirements 4090-9105, Class B operation,two fiber cables required 4090-9107, Class X operation,four fiber cables required Module Size(with mounting bracket) 6-13/16"W x 3-3/4" H x 1-1/8"D(173 mm x 95 mm x 29 mm) Green LED flashing=transmit On-board Status Indicators Red LED flashing =receive Separate red LED on 4090-9107=Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft(914 m)maximum Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Operating Humidity 10%to 90%RH from 32°to 104° F(0°to 40°C) Operating Temperature 32° F to 120° F(0°to 49°C) *Metric wire equivalents: 18 AWG=0.82 mmZ; 12 AWG=3.31 mm2 5 S4009-0002-11 1/2013 � 11 • � � • - • • • • � • • Cabinet depth la 16-1/4"(413 mm) '� 4-1/4"(108 mm) �- 10-29/32"(277 mm) Door,5/8" � a0 OO � � (16 mm)thick�a i 8 O �� �� � � � I o 0 0 0 0 0 0 0 0 � i Optional Class A 4009-9807 Additional Four � 13-1/2" adapter modules point module(shown with ; (343 mm) � Class A adapters) 0 Exposed cabinet ; dimension for , !� System Module � � semi-flush mount ; L�f � 1"(25.4 mm), ; Knockouts for screw IDNet repeater or � 1-3/8"(35 mm)with � or nail mounting holes Fiber optic receiver semi-flush trim 8 � CJ o � � OO OO � �-----------------------------� � I � � � I � � � I � 12"(305 mm) -' � � � I I � � � ��. Battery location,no conduit entry or wiring in i � i this area(12.7 Ah battery outline shown) � � i � i � �i i i Semi-flush trim option Non-power limited wiring area(AC input) 1-3/16"wide(30 mm), �� 3/8"(9.5 mm)thick Wall surface reference for semi-flush mount� NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. � 11 • � � . - . • � . . � - � Optional red applique (4009-9805) r.`../ � 1 1• � - ` � � � ' 6 S4009-0002-11 1/2013 � 1 ' 1 • 1 ' 1 � • - • • • � • • Surface mount box: _�, o 0 0 0 0 0 Simplex model 2975-9217 (ordered separately) Flush mount masonry box: O o O o O o use 6-gang box, RACO#960,2-1/2"deep �� o 0 0 0 0 0 (64 mm),or RACO#965, 3-1/2"(89 mm) O deep, or equal (supplied by others) 0 0 ° o ° ° o ° O Flush mount ganged boxes:� _ _ O ' o use 6-gang box, 1-1/2"(38 mm) � � � � minimum depth;six, RACO#400 C � � � , '� � O O C or equal, (supplied by others) � . � ' � � ' • o � 0 0 0 0 0 0 0 0 0 o IDNet fiber optic transmitter: 4090-9107, Shown,Class A(Style 7)output 4090-9105, Not shown, Class B(Style 4)output INSTALLATION NOTE: Fiber optic cable bend radius should be 2"(51 mm) minimum,or per Manufacturer's specification. 0 0 0 0 0 0 Six-gang blank cover plate Mulberry Metal Products 97156 or equal(by others) - � . . . LED Status Indicators are provided for the following: Power-up Self-Diagnostics.Upon power-up,the • Each NAC(standard and optional)has a dedicated 4009 IDNet NAC Extender tests each module and yellow LED that: performs earth fault diagnostics. Trouble conditions are — During supervision provides a slow flash to indicate communicated to the host control panel and are also a short circuit condition and a fast flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet an open circuit NAC Extender.When connected via lDNet — During an alarm,the LED follows the NAC output communications,detailed status information is available (on steady or flashing with coded output) at the host.When controlled with conventional NAC inputs,common troubles are signaled by providing a • FOUr, general status yellow LEDs provide nine polarized open circuit that disconnects the NAC wiring separate indications listed in priority of urgency.As a from its end-of-line resistor but still allows a reversed trouble is eliminated, any remaining trouble(s)will polarity alarm to be received. then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. Door Mounted Reference Label. The 4009 IDNet NAC Extender has a detailed programming and • AC power status is indicated by a green LED that is diagnostic label inside the front door that provides a quick on when AC is normal. During low AC(brownout) reference for both installation and checkout. conditions or with no AC,the LED is off. Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-11 1/2013 � 1 1 • � � • - • Step 1. Calculate Basic Extender Batterv Requirements (minus NAC loads) Panel, NAC Options, and Auxiliary Power(underlined model numbers are optional modules) Model Descript ion Supervisory Actual qlarm Current Actual Alarm Current Supervisory 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA + 40 mA + 4009-9808 Dual Class A Adapter(no additional current) — — — — Auxiliary Power Output (500 mA + (500 mA maximum) maximum) +[A1] Basic Panel Supervisory Current = [S1] Basic Panel Alarm Current =[A2] Step 2. Calculate IDNet OutpUt Module and Device Current(if used) 4009-9809 IDNet Repeater 70 mA 70 mA 4009-9810* Fiber Optic Receiver,Class B Select one per 65 mA + 65 mA + Extender 4009-9811* Fiber Optic Receiver,Class X 80 mA 80 mA IDNet Devices(connected to Repeater or Receiver above), Total devices Total devices 0.7 mA each, maximum of 100 x 0.7 mA each + x 0.7 mA each + �Note: IDNet Fiber Optic Transmitter IDNet Module Supervisory Current [S2] _ current is supplied from the host fire alarm control panel IDNet Module Alarm Current =[A3] Maximum Available Current =8 A* Step 2. CalCUlate Available NAC Current Subtract Auxiliary Power Output -[A1] Subtract IDNet Module Current -[A3] �8 A for Special Application Appliances;6 A for Regulated 24 DC Appliances Available NAC Current =[A4] Step 3. Calculate Actual NAC Loadinq (Limited to Available NAC Current per Step 2.) NAC Type NAC Circuit# NAC Alarm Current Circuit 1 + Circuit 2 + Standard Panel NACS,2 A maximum per NAC Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1_5 A maximum Special Application rating, Circuit 6 + 1 A maximum Regulated 24 DC rating, per NAC Circuit 7 + Circuit 8 + Total Actual NAC Load Alarm Current =[A5] Step 4. Calculate Total Supervisorv Current Total Supervisory Current=Basic Panel Current[S1]+ IDNet Module Current[S2]_ Step 5. Calculate Total Alarm Current Total Alarm Current= Basic Panel Current[A2]+ IDNet Module Current[A3] +Actual NAC Current[A5] _ TYCO,SlMPLEX,and the product names disted in this niaterial a��e marl s and/or�registered mar�ks.Una�tithorized use is strictly pi�ohibited. �05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4009-0002-11 1/2013 www.simplexgrinnell.com �2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice. �oSimplex TrueA/ert° Multi-Candela Notification Appliances UL, ULC, CSFMListed; FMApproved; SmartSyncT"' Operation Audible/Visible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable � __ �__-====— – ` —.�� II;9IImil E — 5. �,:; . . � . � . pp II„ ! II �� eff cient ellectron�o ntandthigh output xe onh II �� �� strobe, available for wall or ceilin mount: - - 9 �� �� • Operation is compatible with ADA requirements(refer ° . - - � � ` to important installarion information on page 3) � o • Ru ed hi h im act flame retardant thermo lastic �� , g P , P - — . . � I ! hous�ngs are available m red or white with clear lens y� � � � I Operates over a two-wire SmartSync circuit to II��� _ ______- �' provide: - • Horns that are controlled separately from strobes on the same two-wire circuit _-� • "On-until-silenced"and"on-until-reset"operation on m � � � the same two-wire pair _;�; � • SmartSync horn activation of Temporal pattern,March � � �� � I �� y Time pattern(at 60 BPM),or on continuously � � I � • Strobe appliances on the same circuit operating at a � m i �� synchronized 1 Hz flash rate �� _�r � • Operation requires connection to a compatible " SmartSync operation NAC or to SmartSync Control Wall and Ceiling Mount A/Vs Module(SCM)4905-9938 � - • . Wall mount A/Vs features: • Wiring terminals are accessible from the front of the Multi-Candela TrueAlert ANs with horn and housing providing easy access for installation, synchronized strobe provide convenient installation inspecrion,and testing to standard electrical boxes.The enclosure designs are both impact and vandal resistant and provide a convenient • Covers are available separately to convert housing color strobe intensity selection. Since each model can be • Optional UL/ULC listed sound damper for locations selected for strobe intensiry output,on-site model requiring attenuation of 5 to 6 dBA(stairwells, small inventory is minimized and changes encountered during rooms,highly reverberant areas,etc.) construction can be easily accommodated. Optional adapters and wire guards: Wall mount A/V housings are a one-piece assembly • Wall mount A/V adapters are available to cover surface (including lens)that mounts to a single or double gang,or mounted electrical boxes and to adapt to Simplex° 4"square standard electrical box. The cover can be 2975-9145 boxes quicldy removed(a tool is required)and covers are • UL listed red wire guards are available for wall or available separately for color conversion. ceiling mount ANs* Ceiling mount ANs install using standard 4"electrical Visible notification appliance (strobe): boxes. Color choice is determined by model number. • 24 VDC xenon strobe; intensity is selectable as 15, 30, � � . � 75,or 110 candela with visible selecrion jwnper secured behind strobe housing During installation,a selection plug at the back of the • Regulated circuit design ensures consistent flash output housing determines the desired strobe intensiry. An and provides controlled inrush current attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the • Listed to UL 1971 and ULC 5526 side of the strobe lens. Audible notification appliance (horn): � Refertopage2forguardlisting.ThisproducthasbcenapprovedbytheCalifomia�ate • Low current,24 VDC electronic horn with harmonically Fre N�rshal(CSFN�pursuant to Sedion 13144.1 ofthe Califomia Health and SaFely Code.See CSFM Listing 7125-0026:317 fa-allw✓able val�s arxVa coriditiais corioerning rich sound output suitable for either steady or coded rreterial preserrted in tftis docurrent.It is subjed to reexarrination,re��a,,and pcssible operation(Temporal or 60 BPM March Time pattern) ��Iation.Pca�tedfause—QtyofNewYalcDe{�rtmentofBuildings—NFA.'35-93E Refer to page 2 fa listing stat�s of voire guards.Additional listirgs rray be applicable; • Listed to UL 464 and ULC 5525 cont2ctyourla�Sirrplexprak�ctsupplierforthelateststatus.Listirx�andap�xovals urxier Slrrplex Tirre Ft�a-der Co.are the properiy�Tyco SaFety Products Westrririster. '" Sirrplex rrulti-c�ndela Srrnrt5)rtic tvoo-w+re horti/strobe appliance operation is proteded urxiPx one a mxe of the fdlo�,ning U.S.Paterrt Narri�ers:5,559,492;5,622,427; 5,865,527;5,886,620;6,281,789;6,954,137;7,005,971;and 7,006,003. S4906-0002-5 9/2009 . . - � . . . . . . . Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-unril-reset." . - . . . - . . . Multiple Strobes.When multiple strobes and their • 4006,4008,4100U,and 4010 Fire Alarm Control reflections can be seen from one location, synchronized Panels(refer to individual product data sheets for more flashes reduce the probabiliry of photo-sensitive reactions information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSynC compatible notification appliances include separate horns and combination . • . horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE"Lettering Description 4906-9127 Red White Wall Horn with Multi-Candela Strobe;strobe intensity selectable as: 4906-9129 White Red 15, 30, 75,or 110 candela; operates with SmartSync two-wire 4906-9128 Red White control Ceiling 4906-9130 White Red Wall Mount A/V Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20;field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm) NOTE:After Sound Damper installation, measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter Model Description Dimensions 4905-9961" Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3" (216mmx156mmx76mm) 4905-9928� Ceiling Red Adapter Plate, required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) `UL listed by Space Age Electronics Inc. 2 S4906-0002-5 9/2009 � . - . Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 DC;see Note 1 below Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Model Type Wall Mount Ceiling Mount Horn Output Sound Type(see Note 2) Steady Coded Steady Coded Ratings (see Note 2 for Reverberant Chamber Test, g6 dBA 82 dBA 87 dBA 83 dBA polar dispersion per UL 464 @ 10 ft(-3 m) reference) Anechoic Chamber Test,per ULC S525 @ 3 m(-10 ft) 88 dBA 94 dBA 90 dBA 98 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Mount Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices forthe Hearing Impaired, changes effective May 1,2004.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fasY'setting. Polar dispersion per ULC S525 testing= -3 dBA at+/-40°off-axis;-6 dBA at+/-50°off-axis. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) . • . • �� �� �� Mounting is compatible with � single gang,double gang,and � o 0 a"(�02 mm)square boxes, �', � 1 ° � �) r IMPORTANT!WALL MOUNT 1-1/2°(ss mm)deep,by others — INSTALLATION HEIGHT REFERENCE 0 0 0 Optional 4905-9838 Sound Damper,field attached Bottom of lens to attenuate sound 5 to 6 dBA � � � IS elthel'eVen with,or slightly Electrical � o o � O above bottom box outline Wiring access hole O of compatible� tt ; � boxes Wiring terminals for �'� ' 0 1 SmartSync operation __ I Mounting Holes: I , NFPA 72 requires 80"(2.03 m) YPm�w°�'II ��� � s�gle gang(2) that the entire lens minimum � --� -� be not less than �C,, ooueie gang(3) g0"and not greater � � � � than 96"above the Tr Insparent housing finished floor and lens assembly Intensity selection plug,accessible only from rear of housing; 15 � � � � factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-5 9/2009 . . � . . . Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box Four mounting clamps included,two each side CC - - �'� i o / ° Ceiling reference, , flush mounted box o � Optional 4905-9915/-9916 Adapter, recommended for surface mounted box Wiring terminals are Optional 4905-9927 � located behind the housing Red Wire Guard � � � � End View m m I —------------� Strobe intensity viewing slot m m Intensity selection plug, ; � accessible only from rear of lens � housing;factory setting is 15 cd � • • � • • • • � • • Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt ° and Optional Wire Guard � Surface mount conduit and o box shown for reference 4"(102 mm)square � , TM°°°°°^-� �� 0 box profile, 1-1/2" �---- � (38 mm)deep � Optional I � O O 4905-9961 � � — — Wire Guard � � q/V ----- � o � � W � 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered tr•acfemark ofTyco Indernational Services GnsbH and is used under license.Simplex,the Simplu logo,/DNet, TrueAlert,and SenartSync are erademarks of Tyco I�zternatro�:al Ltd.ancl its afJiliates and are used under lrcense.NFPA 72 and Nadonal Fir�e Alarm Cocle are trademarks ofPhe Narioreal Fire Protection Associatiwi(NFPA). �3 Simplex Tyco Safety Products Westminster• Westminster,MA•01441-0001•USA S4906-0002-5 9/2009 � www.tycosaferyproducts-usa-wm.com C 2009 Tvco Safety Prroducts Weshninstee A!!nohts reserved.A!l spec�icarions and other inforn�alion shown were curT�ent as of docurnent rwision clate arad are subject to change without nodce. ��Simplex TrueAlert° Multi-Candela Notification Appliances UL, ULC, CSFM Listed; Weatherproof Notification Appliances (non-addressable) FM Approved* Wall Mount Visible Only (V/O) and Audible/Visible (A/V) � __ Weatherproof 24 VDC notification appliances for ��,.� ��� extended temperature and extended humidity �%�� ��'� operatiorr. —-— . � r �— -� • NEMA 3R rated enclosure with ratings for indoar or _ � � � outdoor applicarions � _ • Rugged,high impact,flame retardant thermoplastic —�-- — housings are available in red or white with clear lens • Red housings are for indoor or outdoor applications __- - and provide iTV light stable color � °'°°"„ • White housings are for indoor applications with limited UV light exposure --- -� rn �� • Mounting is to matching weatherproof boxes � (required),ordered separately - � � �, � • Wiring terminals are accessible froin the front of the � � �— housing providing easy access for installation, inspection,and testing Agency listings reference: �I • UL listed to Standard 1638 for outdoor applications � � with strobe rated at 75 cd(WP75) �� ° � ° • UL listed to Standard 1971 for indoor applications �� with strobe intensity selectable as 15,60,or 75 candela;indoor applications are compatible with ADA requirements(refer to important installation information on page 4) Weatherproof A/V(top)and Strobe(middle), side view of A/V on Weatherproof Mounting Boxes (bottom) • Separate models are ULC listed to Standard 5526 (strobes)and S525 (horns)for outdoor applications � - . . with strobe intensity selectable as 5,20,or 30 candela (available in red only) Weatherproof multi-candela TrueAlert appliances provide V/O and AN SmartSync operation for indoor and Operation details: outdoor, extended temperature and extended humidity • A visible intensity selection jumper is secured behind applications. The enclosures are impact and vandal the strobe housing resistant and provide a convenient strobe intensity • Polarized input allows connection to comparible selection. Since each model can be selected for intensity reverse polarity,supervised notification appliance output,on-site model inventory is minimized and changes circuit(NAC) encountered during construction can be easily accommodated. • Regulated circuit design ensures consistent flash output and provides controlled inrush current • � - • • A/V appliances have an efficient electronic horn During installation,a selection plug at tbe back of the Synchronized strobe compatibility: housing determines the desired strobe intensity.An • Simplex�fire alarm control panels and NAC attached flag with black letters on a yellow bacicground Extenders when selected to provide strobe allows the selected intensity to be seen at the side of the synchronization or SmartSyncTM two-wire control** strobe lens. Separate strobe Synchronization Modules or "�s product has been appraved bythe Califomia State Fre Nprshal(CSFfv�pusuant to � Section 13144.1 of the Califomia H�Ith and Safety Code.See CSFM Listing SmartSync Control Modules(SCMs)that convert 7125-0026331fa-allo�✓adevaluesarxVaooriditia�scorioeiningrreteri�presentedin conventional NAC inputs to a Smartsync output tr�s doa�m�,t.it�s s�,��ct to��xa�;nat�«,,�s�or,,ar,d��e ca�iat�«,. Ptiditional listirx�s rrey be applic�le;o�ntact your local Sirrplex p-oduc[supplier fa the SmartSync two-wire operation provides: ��������"'�a�aa�-°�isU"a�-s�"�e"r"'e�-a�-�°.azetr��-°p��' of Tyoo Safety Roduds V�kstrrinster. • Horns controlled separately from strobes on the same � �;,,p���„it;-�rx�asrrortsy„ct,,,A.w;r�n�,��tro�e�;ar�op�t;o,,;s���d two-wire circuit, activated as Temporal pattern,March urxleraieorrroreofthefdlo,ningU.S.PaterrtNirrt�ers:5,�s,492;5,s22,a2�; Time pattern(at 60 BPM),or on continuously 5,se�,�2�;5,ass,620;6,2s�,�ss;s,954,137;�,00s,971;and 7,006,00s. S4906-0010-2 12/2009 . . - � . . . . . . Proper selection ofweatherproofnotification is dependent SmartSync two-wire control is available from: on occupancy, location, local codes,and proper applications . 4006,4008,4100U,and 4010 Fire Alarm Control of:the National Fire Alarm Code(NFPA 72),ANSI Panels(refer to individual product data sheets for A117.1;the appropriate model building code: BOCA, more information) ICBO,or SBCCI;and the application guidelines of the . 4009 IDNet NAC Extenders(refer to data sheet Americans with Disabilities Act(ADA). Requirements may differ from indoor appliance applications,contact your local S4009-0002) authoriYy having jurisdiction(AHJ)to assist in determining • SmartSync Control Module(SCM)Mode14905-9938 requirements. (refer to data sheet 54905-0003) • Addirional SmartSync compatible norification • • • appliances include separate horns and combinarion SmartSync operation mode allows a two-wire circuit to horn/strobe notification appliances. provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced"while the strobe operation is "on-until-reset." . . . UL Listed TrueAlert Weatherproof Multi-Candela Notification Appliances "FIRE" UL 1971 UL 1638 Model Type Housing Lettering Description Intensity Intensity Rating Rating 4906-9105 Red White Strobe(V/O) 75 cd 4906-9106 White Red UL listed weatherproof appliance with multi-candela 15,60, 4906-9131 Red White strobe; requires weatherproof box below or 75 cd (setting Horn/Strobe WP75) 4906-9132 �A�V� White Red ULC Listed TrueAlert Weatherproof Multi-Candela Notification Appliances Model Type Housing `�FIRE" Description ULC Intensity Ratings Lettering 4906-9113 Strobe(V/O) Red White ULC listed weatherproof appliance with multi-candela 5,20,or 30 cd 4906-9143 Hor(��j be strobe; requires weatherproof box below Wall Mount Weatherproof Boxes (Required) Model Description Dimensions 4905-9828 Red 5-1/2"H x 6-1/8"W x 1-5/8"D Surface Mount Weatherproof Mounting boxes (140 mm x 156 mm x 41 mm) 4905-9829 White Aftermarket Red Bilingual (French/English) Covers (for field installation) Model Description 4905-9832 Red strobe(V/O)cover White"FEU/FIRE"lettering 4905-9833 Red horn/strobe(A/V)cover Sy1tCh1'0111z8t1011 MOdul@ R@f@P@11C@(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16" in/out 18 AWG(0.82 mm )wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 10 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) 2 S4906-0010-2 12/2009 . - , . Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz; Up to 24 synchronized strobes maximum per NAC UL 1971 Listed Rating 32°to 122° F(0°to 50°C);selectable 15/30/75 cd Temperature UL 1638 Listed Rating -31°F to 150°F(-35°C to 66°C);75 cd rating Range ULC S526&S525 Listed Rating -40°F to 150°F(-40°C to 66°C);5/20/30 cd rating Humidity UL 1971 Listed Rating 10%to 93°/o,at 100° F(38°C) Range UL 1638, ULC S526, & ULC S525 up to 98%,at 104°F(40°C) Wiring Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mmz to 3.31 mmZ);two wires per terminal for in/out wiring Horn Output; Models 4906-9131, 4906-9132, &4906-9143; UL� ULC Ratings as noted Output Sound Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 80 dBA 76 dBA 83 dBA 79 dBA 86 dBA 81 dBA (see Note 2) ULC S525 Anechoic Chamber 96 dBA 96 dBA 99 dBA 99 dBA 101 dBA 101 dBA Maximum RMS Current Ratings (see Note 3 below) UL 1971 Ratings(32° F to 122° F) UL 1638 Ratings 75 cd(WP75) Model Intensity Selection/Temperature 15 cd 60 cd 75 cd 32°F to 150°F -31°F to below 32°F (0°C to 66°C (-35°C to 0°C) V/O Models 4906-9105&4906-9106 77 mA 192 mA 231 mA 189 mA 273 mA A/V Models 4906-9131 &4906-9132 91 mA 204 mA 249 mA 205 mA 277 mA ULC S526/S525 Ratings per Intensity Selection Model 5 cd 20 cd 30 cd V/O Model 4906-9113 115 mA 270 mA 295 mA A/V Model 4906-9143 125 mA 275 mA 322 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL 1971 and UL 1638.This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fasY'setting. Under the same test conditions, coded horn output"peak"sound level readings are typically 4 dBA higher.Anechoic horn output ratings are typically more representative of actual installed sound output 3. Currents of A/Vs are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) � • • • • • • 4-11/32"(110 mm) 1_2�/32�� pptional Bilingual total depth (42 mm) Covers field installed �5-3/8"(137 mm)� f. . o+p� — — ) e� 7 5-17/32" �� O (140 mm) 1��� ��f°,3� D total height �' �' � � � 4-1/2„ 4905-9832 0 � (114 mm} Strobe Cover(red) 6< �_. !.. ..! a...a�.w �� � � 5-9/16"(141 mm) � �C�D[��G3� , between mounting holes 4905-9833 6-1/8"(156 mm) A/V Cover(red) 3 S4906-0010-2 12/2009 . . . � . . . NOTE: For detailed installation information,refer to Installation instructions 579-857 for UL listed products,and Installation instructions 579-885 for ULC listed products. Perimeter gasket, pre-installed Knockouts top, bottom,sides,and back; 5 total Cover to mounting box mounting screws(3)� Weatherproof mounting box(required): O 4905-9828, Red;4905-9829,White 1 Housing(A/V shown) � � Housing to mounting t o � Strobe intensity viewing slot box screws(2) o� � ° 3 Intensity selection plug,accessible � � �� only from rear of housing: / � -------- WP75 �„� _ _--�U"-- UL Listed Models: Models 4906-9105,4906-9106, �� 4906-9131, and 4906-9132 ;factory � setting is WP75,the UL 1638, 75 cd rating Three(3)cover attachment tabs �5� ��.___r located bottom, left and right side 30 ULC Listed Models: Models 4906-9113,4906-9143; Standard cover factory setting is 30 cd (A/V shown) Internal cover gasket is pre-installed Polar Light Dispersion Reference,Each Intensity Selection; Percent of Rated Light Output at 77°F(25°C) IMPORTANT! INDOOR WALL MOUNT Vertical Dispersion Horizontal Dispersion INSTALLATION HEIGHT REFERENCE Angle UL 1971 Typical Angle UL 1971 rypica� Below Minimum Output from Minimum Output l�cis Auis 0 100°/ 322°/ 0 100°/ 320% 5 90°/ 217°/ ±5 90% 214% 10 90°/ 168% ±10 90% 177% T � 15 90°/ 179°/ ±15 90% 175% I 20 90°/ 210% ±20 90% 174% $��� (2.06 m) 25 90°/ 184°/ ±25 90% 170% NFPA 72 requires that the minimum to so so°i �as�i ±30 �s°i 169% entire lens be not less than $0" mounting tabs ss ss°i ��z°i ±ss �s°i �s�i and not greater than 96" ao 46% 189% ±ao �5i 151% above the finished floor 45 3a�i zos°i ±4s �s°i 138% 50 27% 152% ±50 55% 130% 55 22% 166% ±55 45% 121% 60 18°/ 166°/ ±60 40% 117% 65 16°/ 164% ±65 35% 109% 70 15% 163% ±70 35% 105% Horizontal Disqersion Vertical Dispersion �5 13% 159% ±75 30% 98% 80 12% 138% ±80 30% 90% top -9 dB top g5 12% 113% ±85 25% 78% -6 dB left side -6 dB right side -6 dB @75° g0 12% 88% ±90 25% 67% -6 dB -3 dB @60° -3 dB @85° WP75 Intensity Selection Light Output Reference -3 dB @75o O on-axis On- Vertical, Horizontal, @65° pn-axis(0°) 1(0°)rated Angle ��s Below Auis LeftlRight of Auis rated output I output 0° 45° 90° 45° 90° minimal UL 1638 Minimum A/V Sound Dispersion per ULC S525 loss Candela Rating(over 75 35 10 32 15 anechoic testin erformed at 3 m 10 ft temperature range) � J p � ) � Tvpical Candela -1 dB bottom at 77°F(25°C) 2�5 103 24 94 39 Tyco is a registered trademark�f Tyco Tnternational Services GmbH and is used u�ider�license.Simplex,the Simplex logo,TDNet,TrueA[ert,and Smar�tSyrzc are tr�adenzarks of Tyco International Ltd.and its aJfiliates aad are used�inder liceiase.NFPA 72 and NaXional Fire Alann Code are registered trademarks of the National Fire Protection Associakron(NFPA). �3Simplex Tyco Safety Products Westminster• Westminster, MA•01441-0001•USA S4906-0010-2 12/2009 � www.tycosafetyproducts-usa-wm.com C�2009 Tyco Safety Products Weshninster.Al!rights reserved.A!/speciJicurions und other i�fonua6on shown were current us of document revision date and are subject to change without nofice.