PROJECT: vai�
VAI L
PREPARED FOR: vA��
TYPE: DESCRIPTION:
4010-9401 4010ES FIRE CONTROL PANEL
4010-9912 SERIAL DACT
4190-6104 TRUE INSIGHT REMOTE SERVICE
2081-9276 BATTERY 12V 33AH
4606-9102 REMOTE LCD ANNUNCIATOR
4099-9003 MANUAL STATION - DOUBLE ACTION
4098-9714 PHOTO SENSOR
4098-9733 HEAT SENSOR
4098-9792 SENSOR BASE
4098-9798 SSD SOUNDER BASE W/CO MODULE
4905-9835 TEMPORAL CODE 4 MODULE
4098-9794 SENSOR BASE W/SOUNDER
4098-9754 PHOTO SMOKE SENSOR W/HEAT
4098-9795 DUAL ADDRESS SOUNDER BASE
4098-9756 DUCT SENSOR HOUSING-4-WIRE
2098-9806 REMOTE TEST STATION
4098-9857 SAMPLING TUBE 46"TO 71"
4090-9001 SUPERVISED IAM
4090-9002 RELAY IAM
4009-9201 NAC EXTENDER 120VAC, IDNET
4009-9807 NAC CARD, 4PT, IDNET
2081-9275 BATTERY 18AH
4906-9129 HORN/STROBE MC WHITE
4906-9130 HORN/STROBE MC WHITE CEILING
4906-9131 WP HORN/STROBE MC RED
4905-9828 WP A/V BACKBOX RED
�oSimplEx 4010m Fire Control Panels
UL, ULC, CSFM Listed; Addressable Fire Detection and Control
FM, NYC Fire Dept Approved* Basic Panel Modules and Accessories
�
Basic system includes:
• Capacity for up to 248 addressable devices,up to � '� �
127 VESDA SLl points,up to 2000 points of r---�.--. ��
Annunciation and up to 20 internal and external card ����
addresses � � ���� �
• Color-coded operator interface with membrane �pIIII�VI�lllll@lU�lllllll�lllllll�lllllll�l�llllll�lllllll�ll
keypad includes 2 x 40 Super-twist LCD display,
3 programmable control keys and 6 programmable
LEDs
• CPU assembly includes dedicated compact flash 4010ES Fire Alarm Control Panels are available
memory for on-site system information storage and standard (left)or with LED Annunciation (right)
convenient Ethernet service port access
• 8 A power supply with up to 2 A of Auxiliary power
and battery charger capacity for up to 110 Ah batteries COmpatlble Wlth SlmpleX° remOtely IOCated:
(UL)or up to 50 Ah batteries(ULC)(33 Ah max in • 4098-9757 QuickConnect 2 and legacy 4098-9710
control panel cabinet) QuickConnect TrueAlarm smoke sensors
• 4 on-board Class A or B, 3 A NACs and one • 4003EC Small Voice Panels
programmable auxiliary relay output rated far . 4009 IDNet NAC Extenders(4009A)
2 A@ 32 VDC . TrueAlert Addressable Controllers(4009T)and
• Class A ar B Two-loop Isolated IDNet Remote TrueAlert Power Supplies(4009 TPS)
Communications(IDNet+)supports up to . 4081 Series, 110Ah Battery Chargers
248 addressable and analog sensing devices on . 4100-7400 Series Gra hic Annunciators
non-twisted,non-shielded wiring p
• Remote annunciator module support via RUI(Remote • 4190 Series PC Annunciator
Unit Tnterface)communications port,supports either • 4190 Series Fiber Modems and Physical Bridges
Class B(Style 4)or X(Style 7)Pathway operation . 4606-9102 Remote LCD Annunciator,4100-9400
• 48 LED panel mount annunciation provides 40 Red Series Remote InfoAlarm Command Centers, and
and 8 Yellow pluggable LEDs(select models,meets 4602 Series Status Command Units(SCU)and
ULC requirements),optional LED kits are available Remote Command Units(RCU)Annunciators
for custom LED configurations • IP communicator compatibility
Optional Main System Supply and door 4010ES Agency listings:
mounted modules include: UL Std. 864,Fire Detection and Control (UO7z),and
• City Connect(with or without disconnect switches) � Smoke Control Service(iT[JKL),and Releasing
• Alarm Relay Module Service(SYZV)
• Truelnsight Remote Gateway . UL Std.2017,Process Management Equipment
Optional block space modules include: (QvAx)
• Fire Alarm Network Interface Card for 4120/4100 . UL Std. 1076,Proprietary Alarm Units-Burglar
Peer-to-Peer network communications,supports either (APOU)
Class B or X(Sryle 7)Pathway operation . UL Std. 1730, Smoke Detector Monitor(UULH)
• Ethernet connectiviry options include Building . ULC Std. 5527-99,Fire Detection and Control
Network Interface Module(BNIC), SafeLINC Internet (UOJZC)
Interface,and BACpac Ethernet Partal . ULC Std. 5559-04, Supervising Starion(DAYRC)
• Dual RS-232 Module(for printer,PC annunciator or
third parry interface)
• VESDA A1T'f�S 1T'atlOri HI Il L,2V01 IritOI'faCO ' See pages 5 and 6 for additional listing informatioa This product has been approved by
p g the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California
• Serlal DACT Health and Safety Code.See CSFM Listing 7165-0026:0369 for allowable values andlor
conditions concerning material presented in this tlocument.It is subject to
• 8 ZOrie IDC l�/IOCIUIeS C11SS f�OT'B re-examination,revision,and possible cancellation.NYC Fire Dept COA#6095.
Additional listings may be applicable;contact your local Simplex product supplier for the
• 4 POII]t l�uXl�laY'y RO�ay MOClU10 latest status.Listings and approvals under Simplex Time Recorder Co.are the property
.
Physical Bridge Network Modules of Tyco Fire Protection Products.
S4010-0004-7 1/2013
. . . . • -.
4010ES Series Fire Detection and Control Panels 4010ES Block Space Option Cards mount to the left
provide leading edge installation,operator,and service of the 4010ES Main System Supply.There are 3 available
features for customer applications in the mid-range 4"x 5"blocks for mounting 4010ES hardware options.
addressable fire alarm systems market.An on-board Other 4010ES Options: The 4010ES City Connect
Ethernet port provides fast external system
communications to expedite installation and service module or the optional Alarm Relay module mount
activity. Dedicated compact flash memory archiving directly to the Main System Supply.These options are
provides secure on-site system information storage of mutually exclusive.
electronic job configuration files to meet NFPA 72 Network Media modules mount directly to the 4010ES
(National Fire Alarm and Signaling Code)requirements. Network Interface Card.
Modular design.A variety of functional modules are The TrueInsight Remote Gateway mounts on the back
available to meet specific system requirements. Selections side of the 4010ES User Interface Panel.
allow panels to be configured for either Stand-Alone or The Battery Compartment located in the bottom of
Networked fire control operation. the 4010ES cabinet accepts two batteries,up to 33 Ah,
. . without interfering with expansion module space.
The Master Controller and Main System Supply The illustrations below identify mounting locations
are mounted in tbe upper section of the 4010ES cabinet. available for optiona14010ES modules.
; 4"x 5" Main System Truelnsight Remote
3 available 4"x 5�� �BlockA Supply Gateway mounts on
block spaces for � - ••° the back of the 4010ES
� a°x a° ; a°x e° ; � `� User Interface Panel
additional option cards ,
�Block B i Block D;
�—--—--'--——--—� uaiioiiooiouoiooiuuoiuoiiooioouiuoiuouiouiiooi000iuoi000iuoiuoi
Mounting Locations for Optional Modules
� . . .
• Mounting box provides convenient stud markers for • TrueAlarm individual analog sensing with front panel
drywall thickness and nail-hole knockouts for quicker information and selection access
mounting . "Dirty"TrueAlanm sensor maintenance alerts,service
• Smooth box surfaces are provided far locally cutting and status reports including"almost dirry"
conduit entrance holes exactly where required . TrueAlarm magnet test indication appears as distinct
• The hinged User Interface panel easily opens for "test abnormal"message on display when in test mode
internal access . TrueAlarm sensor peak value performance report
• Modules are power-limited(except as noted,such as . ��Install Mode"allows grouping of multiple troubles
relay modules) for uninstalled modules and devices into a single
• Doors include tempered glass inserts,boxes and doors trouble condition(typical with future phased
are available in platinum ar red expansion);with future equipment and devices
• Box and door/retainer assemblies are included with grouped into a single trouble,operators can more
Basic Panel assemblies clearly identify events from the commissioned and
occupied areas
• Module level ground fault searching assists
installation and service by locating and isolating
modules with grounded wiring
• "Recurring Trouble Filtering"allows the panel to
recognize,process,and log recurring intermittent
troubles(such as external wiring ground faults),but
only sends a single outbound system trouble to avoid
nuisance communications
• WALKTEST silent or audible system test performs an
automatic self-resetting test cycle
2 S4010-0004-7 1/2013
• . .
• Convenient and extensive operator information is Convenient Status Information.With the locking
provided using a logical,menu-driven display door closed,the glass window allows viewing of the
display, status LEDs,and available operator switches.
• Multiple automatic and manual diagnostics for Features include a two-line by 40-character,wide viewing
maintenance reduction angle(super-twist)LCD with status LEDs and switches as
• Convenient PC programmer label editing shown in the illustration below.
• Password access control LED indicators describe the general category of activiry
being displayed with the LCD providing more detail. For
• Alarm and Trouble History Logs(up to 2000 total the authorized user,unlocking the door provides access to
events)are available for viewing from the LCD,or the control switches and allows further inquiry by
capable of being printed to a connected printer,or scrolling the display for additional detail.
downloaded to a service computer The following illustration identifies the primary functions
of the operator interface.
FIRE ALARM ACK acknowledges a Fire Alarm
condition,logs the acknowledge,and silences the
operator panel and all annunciator tone-alerts
PRIORITY 2 ACK acknowledges a Priority 2 Alarm
condition,logs the acknowledge,and silences the
operator panel and all annunciator tone-alerts
SUPV ACK acknowledges system supervisory
ULC SYSTEMS 6 SYSTEM STATUS INDICATOR LEDs provide contlitions,logs the acknowletlge,and silences the
require designating system status indications,LEDs flash to indicate operator panel and all annunciator tone-alerts
a Grountl Fault a change in status and remain on-steady after TROUBLE ACK acknowledges system trouble
indicator acknowledged until reset conditions,logs the acknowledge,and silences the
operator panel and all annunciator tone-alerts
ALARM SILENCE causes audible notification
2 X 40 LCD READOUT,LCD is appliances to be silencetl(depending on panel
3 PROGRAMMABLE LEDs backlighted during normal conditions, programming)typically after evacuation is complete and
two selectable as Red or Yellow, provides up to 40 characters for custom while alarm source is being investigated;may allow
one selectable as Green or Yellow label information visible notification to continue(strobes still flashing)
FIRST ALARM DISPLAY operation can SYSTEM RESET restores control panel to normal when
Custom label insert be selected for maintained display of first all alarmed inputs are returned to normal
alarm until acknowledged
�b
watert�ow-east •=�1�•=�TEM I:=� IAII_�Fih'IAL
1:�a���rt t� n�r� FRI �4-J'Al�f-1:=
Waterflow-West
Ground Fault -
City Disconnect
Elevator Bypass I
Ground Fault
Latch
� � • • � � � ES
3 PROGRAMMABLE POINT STATUS ADDITIONAL FUNCTION LCD NAVIGATION NUMERIC KEYPAD for
FUNCTION SWITCHES CONTROL KEYS: KEYS: CONTROL: point category and point
with yellow LED Point Enable and Event Time Request Menu selection selection(alphabet
intlicators Disable More Information Request Vertical and characters are not used at
Force On or Arm Lamp Test Horizontal position this time)
Force Off or Disarm selection buttons
Return On/Off or
Arm/Disarm to Auto
Mode
3 S4010-0004-7 1/2013
• • . • • � -
The 4010ES is compatible with an extensive list of remote Status is determined by comparing the current sensor
peripheral devices including printers,PC Annunciators and value to its average value.Tracking this average value as
both conventional and addressable devices including a continuously shifting reference point filters out
TrueAlarm analog sensors. environmental factars that cause shifts in sensitivity.
� • . - , . - � - . . Programmable sensitivity of each sensor can be
selected at the control panel for different levels of smoke
Overview.The 4010ES provides standard addressable obscuration(shown directly in percent)or for specific
device communications for IDNet compatible devices. heat detection levels. To evaluate whether the sensitivity
Using a two wire communications circuit,individual should be revised,the peak value is stored in inemory and
devices such as manual fire alarm stations,TrueAlarm can be easily read and compared to the alarm threshold
sensors,conventional IDC zones,and sprinkler waterflow directly in percent.
switches can be interfaced to the addressable controller to
communicate their identity and status. CO sensor bases combine an electrolyric CO sensing
Addressability allows the location and condition of the module with a TrueAlarm analog sensor to provide a
connected device to be displayed on the operator interface single multiple sensing assembly using one system
LCD and on remote system annunciators.Additionally, address. The CO sensor can be enabled/disabled,used in
control circuits(fans,dampers,etc.)may be individually LED/Switch modes and custom control, and can be made
controlled and monitored with addressable devices. public for communication across a fire alarm Network.
(refer to data sheet 54098-0041 for details)
Addressable Operation. Each addressable device on
the communication channel is continuously interrogated TrueAlarm heat sensors can be selected for fixed
for status condition such as:normal,off-normal,alarm, temperature detection,with or without rate-of-rise
supervisory,or trouble.Both Class B and Class A detection.Utility temperature sensing is also available,
pathway operation are available. Sophisticated poll and typ�cally to provide freeze warnings or alert to HVAC
response communication techniques ensure supervision system problems.Readings can be selected as either
integrity and allow for"T-tapping"of the circuit for Fahrenheit or Celsius.
Class B operation. Devices with LEDs pulse the LED to TrueSense Early Fire Detection.Multi-sensor
indicate receipt of a communications poll and can be 4098-9754 provides photoelectric and heat sensor data
turned on steady from the panel. using a single 4010ES IDNet address. The panel evaluates
IDNet+ Channel CapaCity. The Main System Supply smoke activity,heat activity,and their coinbination,to
provides an IDNet+signaling line circuit(SLC)that provide TrueSense early detection. For more details on
supports up to 248 addressable monitor and control this operation,refer to data sheet 54098-0024.
devices intermixed on the same pair of wires. � . � � , � � _ � . � _
IDNet+ Communications wiring specifications.
IDNet+circuits may be run on NEC 760 untwisted pair, Sensor Status. TrueAlarm operation allows the control
twisted pair,or shielded twisted pair conductors. panel to automatically indicate when a sensor is almost
dirty,dirty,and excessively dirty. The NFPA 72
IDNet+Wiring Specifications requirement for a test of the sensitivity range of the
Size 18 AWG(0.82 mm�) sensors is fulfilled by the ability of TrueAlarm operation
Type NEC 760 Wire(untwistetl,twisted, to maintain the sensitivity level of each sensor. CO
or shielded twisted pair) Sensors track their 5 year active life status providing
Farthest Distance 126-248 Up to 2500 feet(762 m) indicators to assist with service planning.Indicators occur
from Control Panel at: ] year,6 months,and when end of life is reached.
per Device load up to 125 Up to 4000 ft(1219 m)
Modular TrueAlarm sensors use the same base and
Up to 12,500 ft(3.8 km) different sensor types(smoke or heat sensor)and can be
Total Wire Length Allowetl Class Note:The sum of line-to-line easily interchanged to meet specific location requirements.
A or Class B,including"T-taps" capacitance plus the capacitance
for Class B wiring(total for both of either line-to-shield(if shield is This allows intentional sensor substitution during building
isolated circuits combinetl) present)=0.6 NF inaximum(total construction when conditions are tempararily dusty.
for both isolated circuits combined) Instead of covering smoke sensors(causing them to be
*Other circuits may require shielded wiring.Review your system with disabled),heat sensors may be installed without
your local Simplex product supplier. reprogramming the control panel. The control panel will
indicate an incorrect sensor type,but Y11e heat sensor will
- � • • - • operate at a default sensitivity to provide heat detection
for building protection at that location.
Addressable device communications include operation of
TrueAlarm smoke and temperature sensors. Smoke
sensors transmit an output value based on their smoke
chamber condirion and the CPU maintains a current
value,peak value,and an average value for each sensor.
4 S4010-0004-7 1/2013
• • � - � •
• The 401 OES Master Controller includes dedicated 4010ES panels include: an Operator Interface,Master
2GB compact flash Mass Storage memory for on-site Controller with 2GB Compact Flash, Class A or B Two-
system information storage and convenient Ethernet loop Isolated IDNet Communications(IDNet+)
service port access supporting up to 248 addressable and analog sensing
• Convenient front panel accessed Ethernet port for devices, 8 A power supply with up to 2 A of auxiliary
quick and easy download of site-specific power, 110 Ah(UL)/50 Ah(ULC)battery charger
programming (33 Ah maximum in the control panel cabinet),4 Class A
or Class B NACs rated @ 3 A each for Special
• AND,firmware enhancements are made via software Application and 2 A for Regulated 24 DC operation,
downloads to the on-board flash memory 1 programmable auxiliary relay rated for 2 A@ 32 VDC,
• Every downloaded job is automatically stored to 1 RUT Class B or X communications port for remote
Compact flash without overwriring earlier versions annunciation devices,cabinet,and door.
providing a means for recovering previous
configurations Support is for up to 20 internal and external card
addresses. Other standard options may be provided
• Downtime is reduced because the system stays depending on model (see basic panel model selection
running during download below for additional details on specific models).
• Modifications can be uploaded as well as
downloaded for greater service flexibility ' '
• Mass Storage allows job specific files to be store in The Main System Supply provides the power source and
the control panel such as test and inspection reports, the Input/Output connections for the basic 4010ES panel.
record drawings, specifications,and more... The main features are listed in the Basic Panel description
• Ethernet connectivity options include Building below.
Network lnterface Module(BNIC)and SafeLINC
InYernet Interface
• RUI(Remote Unit Interface)communications port
supparts either Class B or X Pathway operation far
remote annunciation equipment and for 4009 Series
TrueAlert Controllers and TrueAlert Power Supplies
. . .
Note: Supervisory and Alarm current specifications are for determining battery standby requirements. Current specifications
include an active RUI channel and alarm currents include 20 IDNet device LEDs activated.Actual IDNet channel device
current is not included, refer to page 6 for details. For models with 48 LED Annunciation, alarm also includes 24 LEDs
activated.
Panel Language& Supv. Alarm Available
Model" Color Voltage Listings Features Current Current Option
Blocks
4010-9401(BA) Red Basic panel with 2x40 LCD Operator
English UL, CSFM, FM, �nterface and (1)Two-loop Isolated
120 VAC NYC Fire Dept IDNet+Channel, Class A or B,with 316 mA 430 mA
4010-9402(BA) Platinum support for up to 248 addressable
devices
3
4010-9403(BA) Red English UL, ULC, 4"x5"
120 VAC CSFM, FM, blocks
4010-9404(BA) Platinum NYC Fire Dept
Same features as above with 48 LED 336 mA 495 mA
annunciation
4010-9405 Red French ULC,CSFM,
4010-9406 Platinum 120 VAC FM
*Models with(BA)are available as assembled in the USA by adding the suffix"BA".
5 S4010-0004-7 1/2013
� • • . • - � - • . • • - • • • •
Addressable Channel Device Load Supervisory Alarm
Current Current
With 248 Devices,Add 199 mA 248 mA
Main System Supply IDNet+Channel Output With 125 Devices,Add 100 mA 125 mA
(does not include device LEDs in alarm)
With 50 Devices,Add 40 mA 50 mA
• • . • • • • •
Note: Refer to diagram on page 2 for Option Module availability. Supervisory and Alarm current specifications are for determining
battery standby requirements.
Single Block Option Modules, Select Three(3) Maximum if No Dual Block Module is Selected;
Select One(1) Maximum if a Dual Block Module or the Module Bracket is Selected
Model Features Option Block Usage Supervisory Alarm
Current Current
1 Block
4010-9912 Serial DACT (must mount in block D 30 mA 40 mA
under main system supply)
4010-9908 4 Point Aux Relay Module 1 Block 15 mA 60 mA
Voltage Regulator Module,22.8 to 26.4 VDC 4.9 A
(25 VDC nominal); isolated and resettable output; 3 A maximum
4010-9916 includes earth detection circuit and trouble relay 1 Block with 2.5 A load maximum
for status monitoring with 4 A load
4010-9918 Dual RS-232 Module 1 Block 60 mA 60 mA
4010-9915 BACpac Ethernet Portal Module; requires 1 Block 123 mA 123 mA
4010-9918 RS-232 Module(no address required)
4010-9901 VESDA HLI 1 Block 60 mA 60 mA
Dual Vertical Block(Flat) Modules, Select One, or Two with 4010-9928 Bracket Kit(except for Media Cards)
Model Features Option Block Usage Supervisory Alarm
Current Current
Dual Vertical Block Card Mounting Kit, allows
4010-9928 selecting two,dual Vertical Block(flat)modules 2 Vertical Blocks NA NA
from the list below
Modular Network Interface Card
4010-9922 (requires two media modules,see below) 2 Vertical Blocks 30 mA 30 mA
4010-9818 Network Media Card Wired N�q 55 mA 55 mA
4010-9819 Network Media Card Fiber Optic (mounts to 4010-9922) 25 mA 25 mA
4010-9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA
4010-9923` SafeLINC Internet Interface 2 Vertical Blocks 115 mA 115 mA
4010-9924� Modem Physical Bridge Class B(Style 4) Requires one of the 2 193 mA 193 mA
Vertical Block spaces on the
4010-9925* Modem Physical Bridge Class X(Style 7) 4010-9928 Mounting Kit 246 mA 246 mA
4010-9926'" TCP/IP Physical Bridge Class B(Style 4) 3 Block"L"Shape, requires 196 mA 196 mA
one of the 2 Vertical Block
4010-9927�` TCP/IP Physical Bridge Class X(Style 7) spaces on the 4010-9928 236 mA 236 mA
Mounting Kit, plus Block D
Dual Vertical Block(Slot) Modules, Select One if no Dual Vertical (Flat) Modules from Above are Selected
Model Features Option Block Usage Supervisory Alarm
Current Current
4010-9920 8 Zone Initiating Device Circuit-Class B 2 Vertical Blocks
mother/dau hter card 75 mA 195 mA
4010-9921 8 Zone Initiating Device Circuit-Class A � 9 )
'UL, ULC,and CSFM listed.
`�FM Approved only.
6 S4010-0004-7 1/2013
� • • • • • • • • • • . • - •
Model Features Supervisory Alarm Mounting Requirements
Current Current
4010-9909 City Connect Module w/disconnect switches 20 mA 36 mA
4010-9910 City Connect Module 20 mA 36 mA Select one maximum, mounts
on Main System Supply
4010-9911 Alarm Relay Module 15 mA 37 mA
4190-6104� Truelnsight Remote Gateway 62 mA 62 mA Mounts on Front Door
4100-5128 Battery Distribution Terminal Block, mounts to side of box, required when battery connection leaves the 4010ES
box(also used in the 4100ES fire alarm control panel)
*Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details.
• � .
Front view,cabinet outline without door Side view with door attached
16"(406 mm)
Total depth, —--— Box depth,
box and door 6-29/32"
11-11/16"
(296 mm) ' (175 mm)
Exposed cabinet for
Use 4 holes to semi-flush mounting
Secure box to wall 1-3/8"(35 mm)minimum
22"
(559 mm)
Stud alignment
Exposed door and cabinet markers, each side
for semi-flush mounting
6-1/8"(156 mm)minimum 6"stud
,-----------------------------------�
Door thickness 4"stud
o Reserved for Batteries o 4-3/4"(121 mm)
�--- ---��_
24"(610 mm)
. � .
LED Kits
Model Description
4100-9843 8 Yellow LED Kit
4100-9844 8 Green LED Kit
4100-9845 8 Red LED Kit
4100-9855 8 Blue LED Kit
End User Programming Tools
Model Description
4100-8802 End User Programming Unit Software
4100-0292 Custom Label Editing (USB Dongle)
4100-0295 Port Vectoring Setup and Control (USB Dongle)
4100-0296 User Group/Passcode Editing(USB Dongle)
4100-0298 WalkTest Configuration Setup and Control(USB Dongle)
4010ES Factory Programming
Model Description
4010-8810 4010ES Factory Programming
4010-0831 Custom Label and Panel Programming
7 S4010-0004-7 1/2013
� 1 1 • ` • • � • •
The 4010ES has a maximum Internal and External Card Address Limit of 20 Card Addresses.Use the Table below to calculate
4010ES card address allocation.
INSTRUCTIONS: Below is a list of 4010ES equipment and the quantity of card addresses they consume
1. For the applicable control panel,write in the Card Address Consumption value in the Card Address Allocation column.
(Note:Only select 1 control panel)
2. For the option cards to be installed on the 4010ES,write in the Card Address Consumption value in the Card Address Allocation column.
3.Total the Card Address Allocation column(total must not exceed 20).
Model Description Card Address Card Address Notes
Consumption Allocation
Control Panels(Select One)
4010-9401 2x40 Display,Single IDNet Channel,Single Bay Box 2
4010-9402
4010-9403
4010-9404 4010-9405&
4010-9405 2x40 Display,Single IDNet Channel,48 Pluggable LED Module 3 4010-9406 are for
4010-9406 Canada
Panel Option Cards(Select As Required)
4010-9901 Flat VESDA HLI Card 1
4010-9922 Flat Network Card 1
4010-9908 4 Point Flat Aux Relay Module 1
4010-9912 Serial DACT 1
4010-9923 SafeLINC Internet Interface Card 1
4010-9914 Building Network Interface Card 1
4010-9918 Dual RS-232 Module 1
4010-9920 8 Zone Initiating Device Circuit-Class B 1
4010-9921 8 Zone Initiating Device Circuit-Class A 1
Remote Power/Notification(Select As Required)
4009-9401 TrueAlert Addressable Controller(4009T)120 VAC 1
4009-9402CA TrueAlert Addressable Controller(4009T)w/Low Battery Cutout 1 for Canada
4009-9813 Transponder Interface Card for 4009 TPS 1
4100-5120 120 VAC Domestic TrueAlert Power Supply for 4009 TPS 1
4100-5121 120 VAC Canadian TrueAlert Power Supply for 4009 TPS 1 for Canada
Remote Annunciation(Select As Required)
4100-9401 Red Cabinet, English 2
4100-9403 Remote Platinum Cabinet, English 2
4100-9421 InfoAlarm Red Cabinet, French 2 for Canada
4100-9423 Command Platinum Cabinet, French 2 for Canada
4100-9441 Center Red Cabinet,with blank inserts for key labels 2
4100-9443 Platinum Cabinet,with blank inserts for key labels 2
4606-9102 4010ES RUI LCD Annunciator, English 1
4606-9102BA 4010ES RUI LCD Annunciator,English 1
4606-9102CF 4010ES RUI LCD Annunciator, French 1 for Canada
4602-9101 Status Command Unit(SCU)LED Annunciator 1
4602-9102 Remote Command Unit(RCU)LED Annunciator w/control 1
4602-9150 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1
4602-7101 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1
4602-7001 RCU for cabinet mount 1
4602-6001 SCU for cabinet mount 1
4100-7401 24 Point I/O Graphic Module for custom annunciator panels 1
4100-7402 64/64 LED Switch Controller for custom annunciator panels 1
4100-7403 32 Point LED Driver Module for custom annunciator panels 1
4100-7404 32 Point Switch Input Module for custom annunciator panels 1
Total Card Addresses(Not to Exceed 20) TOTAL
8 S4010-0004-7 1/2013
. .
AC Input Current 4 A maximum, 120 VAC @ 60 Hz nominal
Including module currents and auxiliary power Output switches to
Power Supply Output Total Power Supply outputs; 8 A total for"Special Application" battery backup
Ratings(nominal 28 VDC Output Rating appliances;4 A total for"Regulated 24 DC"power during mains AC
on AC,24 VDC on (see below for details) failure or brownout
battery backup) conditions
Auxiliary Power Tap 2 A maximum, rated 19.1 to 31.1 VDC
Special Application Simplex 4901,4903,4904,and 4906 Series horns, strobes, and combination horn/strobes and
Appliances, maximum of speaker/strobes(contact your Simplex product representative for compatible appliances)
70 appliances per NAC
Regulated 24 DC Power for other UL listed appliances; use associated external synchronization modules where
Appliances required
UL listed for battery charging of 6.2 Ah up to 110 Ah; ULC listed for
Battery capacity range charging up to 50 Ah batteries; batteries above 33 Ah require separate
Battery Charger Rating cabinet
(sealed lead acid
batteries) Charger characteristics Temperature compensated,dual rate, recharges depleted batteries within
and performance 48 hours per UL Standard 864;to 70%capacity in 12 hours per ULC
Standard S527
Operating Temperature 32°to 120°F(0°to 49°C)
Environmental
Operating Humidity Up to 93°/o RH, non-condensing @ 90° F(32°C)maximum
Additional Technical Installation Instructions 579-989
Reference Operating Instructions 579-969
� • • . . . . • . . •
Subject Data Sheet Subject Data Sheet
4010ES Agent Release Applications and S4010-0005 Network Communications S4100-0056
Accessories
Agent Release Accessories S2080-0010 Multi-Signal Fiber Optics S4100-0049
Building Network Interface S4100-0061 4602 Series SCU/RCU S4602-0001
SafeLINC Internet Interface S4100-0062 PC Annunciator S4190-0013
Interface to VESDA Air Aspiration Detection S4100-0026 TrueAlert Addressable Controller(4009T) S4009-0003
Systems
Serial DACT(SDACT) S2080-0009 4009 IDNet NAC Extender S4009-0002
Fire Alarm Network Overview S4100-0055 4003EC Voice Control Panel S4003-0002
Truelnsight Remote Service S4100-0063 120 VAC Desktop Remote Printer S4190-0011
Addressable Device Compatibility, IDNet 4009 TPS(Remote TrueAlert Power Supply)
Communication Sensors and Devices S4090-0011 Reference S4100-0037
4606-9102 Remote LCD Annunciator S4606-0002 110 Ah Batteries and Cabinets S2081-0012
Graphic I/O Modules S4100-0005 Remote 110 Ah Battery Chargers and Cabinets S4081-0002
Remote InfoAlarm Command Center S4010-0008 BACpac Ethernet Portal Module S4100-0051
PC Annunciator S4190-0013 Network Physical Bridge S4100-0057
TCP/IP Physical Bridge S4100-0029
9 S4010-0004-7 1/2013
TYCO,SIMPLEX,and the product names listed ni this material are marks and/or registered marks.Uriauthor�ized use is str�ictly prohibited.VFSDA is a trademark ofXtralis Pty
Ltd.NFPA 72 and National Fire Alarm and Signaling Code m�e trademarks of�the National Fire Protectlon Assoclatron(NFPA).ASHRAE and BACnet are Krademarks of
ASHRAE,American Society of Heating,Refrigeration,and Air Conditioning F_ngineers.
�05 i m p I Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4010-0004-7 1/2013
www.simplexgrinnell.com
O 2013 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are su6ject to change without notice.
�oSimplEx Fire Control Panel Accessories
UL, ULC, CSFM Listed� Truelnsight Remote Service
Overview and Hardware Reference
� Remote Truelnsight Remote
Real time data gathering and diagnostics for fire Technician's Service Center
alarm control panel systems: Computer
• An internally mounted interface module securely connects f –� � Local
the panel computer port protocol interface to an Ethernet Technician's
connection allowing information about trouble(or Computer ����
potential trouble)conditions to be sent to the Remote ��°� �-�
�!
Service Center via an Internet connection Technician's � �--���
• At the Remote Service Center,receipt of trouble Computer Firewall i
information triggers an email to an experienced technician -� ,��I����� ; ,
who reviews the informarion and can further query the � ;+�=!��
panel for more information as the condition is invesrigated;
(NOTE:Alarm information is only logged by this service; �"���
�-'� I' I
Alarin information must be sent separately to the ` �--�
designated monitoring/response location.) �
• Technicians can connect to the panel from a remote Service Center Firewall
location via secured internet communications and
interrogate the system status
• After details of the panel status are analyzed,tbe service
personnel dispatched to the site can be selected for their
specific experience and equipped with the needed Internet Connection
replacement parts and tools before visiting the site
• Truelnsight Remote Service logs panel activity(troubles
and alarms)and maintains it for one year allowing detailed
activity historical review or forensic review if required Customer Firewall
Application Details: r -- ---
• For use with Simplex°4100ES,4010ES, and 4100U Fire = �a
Alarm Control panels � 4100ES Panel
• Module connects without need for panel programming with 4190-6104
S@CUP@ COI'T1111UflIC8t1o11S: � � I ; o- Truelnsight
• Control panel interface module is connected behind / ����� module
customer's firewall mimimimi�iwiwi�imimimimioiu�uui�u�
mimimimi�imimiwimimimimmimm�im�
• Receiving equipment resides under the Remote Service _ _____
Center firewall or under the individual technician's — —
computer firewall Truelnsight Remote Services Reference Diagram
• Customer to provide network access/connectivity (4100ES shown for reference)
Additional Information:
• Contact your local Simplex product representative for • • - • • • •
specific details on how to connect your panel to
TrueInsight Remote Services Modules and remote devices of a fire alarm control panel
are interconnected with internal wiring harnesses and with
� � � external wiring. Over time,or even during initial
installation,those connections may become loose or
Connecting to Control Panel Intelligence.4100ES, otherwise compromised. Due to module and wiring
4010ES,and 4100U addressable fire alarm control panels supervision,these trouble conditions are discovered and
provide intelligent monitoring of internal modules, incoming their locations are identified by the panel.
power,battery connections,and of connected remote devices (continued nextpage)
and appliances such as TrueAlarm analog sensors,TrueAlert
addressablenotification,devicescontrolledb IDNet ` T�"s���"�'���'tr,ec,��f«„�ast�eFrerv��sna��csFm�p�,�,tto
�' Section 13144.1 of the Califania H�Ith and SaFety Code.See CSFM Listings
communications,and the connected wiring. TrueInsight 71G�r0026:0251 and7165-00'16:Q369for�laval�evaluesand/orconditior�so�r�erning
Remote Service monitors this information and takes action ���Pr��intFtisdocurrent.ltissubjecttoree�rririation,re�s�a,,and
posside cance�lation.This produd was not FM apFxoved or accepted by the NYC FD�
when trouble conditions arereported. o�docu�re�;s�o„date.adda�a,a�us���s�reyneapp�ca�e;ca,�aayouri«�
Sirrplex product supplier fa the latest status.Listings and approvals under Sirrpleac Tme
Reoorder Co.are the property of Tyco Fre Protection Prock�s.
S4100-0063-3 3/2013
• • ' • • • • 1 'I
Devices and their wiring are subject to motion. TrueAlarm Sensor Monitoring (Continued).
Mechanical wiring disturbances can be due to a variety of Should a difficult environment experience nuisance
subtle or significant activity such as earthquakes(even alarms,this diagnosric tool can be accessed remotely as a
seemingly minor earthquakes may shake buildings more means of analyzing the stability of the sensor's
than expected),farklift activiry coming closer than environment. This allows the sensor sensitivity to be
planned, large fire doors or outside shipping dock doors properly selected for its actual environment ensuring
slamming shut closer to fire alarm devices tban realized, optimal response time and protecrion from nuisance alarm
and other human intervention can unintentionally cause sources.
fire alarm wiring connections to becon�e loose or broken. gatteries wear out.Fire alarm control panels typically
When the panel discovers this type of condition,it rely upon internally mounted,or perhaps remotely
declares a trouble,the circuit and specific condition is mounted batteries with battery chargers to provide power
logged and identified with a local sound and flashing during local AC mains failure. Rechargeable batteries are
yellow light,however the exact details are not normally complex chemical/mechanical/electrical designs and after
available other than by querying the individual panel for repeated charge and discharge cycles,will begin to lose
more information on-site.Accessing this information total capacity. By monitoring battery capacity at the
remotely allows TrueInsight Remote Service personnel to panel,battery condition can be tracked,but to better
determine the source of the trouble including which understand battery charging status,detailed charger
devices by specific model number may be involved. operation needs to be queried.Using TrueInsight Remote
Smoke sensors get dirty. TrueAlarm smoke sensors Service allows that extra information to be investigated to
are open to the environment in arder to sample for the diagnose specific panel conditions and then to determine
presence of smoke particles.This also allows a collection whether it is time to replace batteries,inspect battery
of dirt ar other debris, sometimes a lot of it,and in a short connections,or to test the battery charger,allowing the
period of time. TrueAlarm technology compensates very anticipated equipment to be available at the time of a
well up to the point where a device is identified as dirty service call.
and needs to be inspected and cleaned.Knowing that a Monitoring includes communicating devices and
sensor is in need of service before it actually gets out of devices they monitor.With IDNet communicarions,
compensation allows a system to provide essentially these panels monitor and control a wide variety of
uninterrupted service. remotely connected devices.If communications fail to
TrueAlarm Sensor Monitoring. TrueAlarm smoke properly operate,the device(s)not communicating are
sensing tracks the Peak Analog Value associated with identified.If the devices are in turn monitoring
each sensor's environment. connections local to their location,such as relay coils,
conventional IDCs or NACs,problems with those
connections are communicated back to the control panel.
. . .
Model Description Ordering Information
4190-8001 Truelnsight Remote Service Module and Programming Selection
Truelnsight Remote Service Module Installation Kit; includes Required Selection
4190-6104 module, required mounting brackets and harnesses for either the
4100ES,4010ES, or 4100U
4190-4016 Truelnsight Remote Service Module for fixed IP Addressing Optional, select if application will be
using a fixed IP address
� 1 1 .
���IIII��������II���������I�I��������IID�I�����II�D��II�����������DDD�DD��������I I�����0�0�0000_�00���0�I��O� 0
����������������o�ii������������������������������oo���o������i���������������������o�����a�������������o�a���ea� ��� � �� ���o� �
ao' �� � °I 0
� `� . � � � � � 'o n�:::::a� _
,� o 0
� ' 0 � �� o o ��� ° �
Truelnsight Module � o o �
o❑o a � � a
mounts here on rear of �
4010ES front panel l rl fl � ffl r l �jfffff f � �
���II��II��I�����III��III I��IIIII����II II�IIII�.���IIII�II�IIII I�II��I����II I�IIII���II�III����III�����.����IIII II�II���.IIIIIIIII����IIII II��II�I�I��III I�II�IIIII� ° a
�����I���������I����I�I��III���I��I II���������I IIII��II��I����I II��I������I�I���II������II��������II��I�II�I������I���������I��I���������I�I�� a a
2 S4100-0063-3 3/2013
. . . -
Determine Connection Location Type:
1. Panel Location requiring internal connection.If
the panel is located in a lobby or other public area,or
is semi-flush with the box essentially fully mounted -- - - - - - -
in the wall,an interna]connection is recommended,
and most likely required.
2. Panel Location allowing external connection.If the i �-o�� � '
panel is in a utility ar telecom closet,or other sio�z'� I°�
controlled access location,and is surface mounted Master
with the box fully exposed, an external jack Contro��er eay=�'
connection is acceptable if desired. , -
Wiring Alternatives: �
1. Internal Connections.Run Ethernet cable through
existing conduit if the conduit is not beyond capacity ,o, POWeI" �Ill'lltGd
(as defined per local codes and standards)and ='�" _'�„ "�„ `
contains only power-limited signal wiring.Ethernet ` Wlring area
cable should not be run in the same conduit as AC -� ° -�� �
power as this will interfere with signal integriry and it pp, z�,, s�� .,��y� � ,, �
may not meet local code. Terminate the cable with an � III ,e�o�,�,„
RJ-45 Male connector or install an RJ-45 Female °;'ok°Fl �
jack(preferred).Attach the female jack to the internal � -, � �
sides of the back box,in the power-limited area of the ! ' �
cabinet(see illustrarion to the right). Use an adhesive
style mount and follow the manufacturer's
instructions such as to use a cleaning solvent like =��„ _��,_ _��,_ =��,a =��,s =��,e =��„ =��,a
alcohol on the box surface before you mount it. � � ��•�M ��-��ro
s ����s ,�Mad��r
2. External Connections.If the Ethernet cable cannot ' � `� �a���E�
be run into the cabinet directly, locate the termination ��� Expan�sion Bay z�`"°;�ps;
within 6 ft(1.8 m)of the panel,on the power limited = I � „a og,
sides,and preferably terminated with an RJ-45 °���b°F;`
Female jack If you have local IT requirements for _, � _ �����s.
_--
�
specific color wire,provide the desired color patch I
cable to extend from the jack to the panel. To allow I
for internal wiring requirements,the patch cable
length needs to be 8 to 10 ft(2.4 m to 3 m)longer Battery Compartment
than the distance from the jack to the panel. (If the
connection is to be provided as a cable terminated
with a RJ-45 Male connector instead of a Female
jack,the distance requirement remains,adequate
cable for a clean connection to the panel plus 8 to 10 Three-Bay 4100ES Showing Power Limited
ft additional for internal cable routing.) Wiring Area (in dark gray)
Panel Access Precautions:
1. If you do not have conduit available or are unsure
about where to route the cable,do not drill into the
panel box. Leave a spool of cable in the ceiling or the
vicinity of the panel (long enough to be routed into
the panel)and coordinate with your Simplex
technical representative as to how to proceed.
Acceptable Cable Types:
1. Use EIA/TIA-568a CAT-S-Compliant Cable or
better.
2. Either Unshielded(UTP)or Shielded(STP)Cable is
Acceptable.
3 S4100-0063-3 3/2013
. . . . - .
Module 4100ES or 4100U Left side of expansion bay bracket, preferred location is bay 2 NOTE: Module locations do
mounting 4010ES On back side of dress panel not require bay space
Voltage 24 VDC,system supplied
62 mA in standby
Current
73 mA maximum when active
Environmental 10 to 93% RH from 32°to 120°F(0°to 49°C)
System Power; RS-232 Communications Port to panel; Ethernet RJ45 connection
Connection Requirements NOTE:When possible,terminate the Ethernet drop in the panel enclosure. If not possible, and
the panel is in a secure area, locate an external drop within 6 ft(1.8 m)of the panel enclosure.
Power/Ready: Steady Green=system ready; Flashing Green or Flashing Yellow=system is
booting up(details are described in Installation Instructions); Red=Error condition
Link/10/100: Green= 10 Mbit connection;Yellow= 100 Mbit connection; Dark=no connection
Module LED Diagnostics(5 LEDs) Activity: Steady Green=heavy traffic; Flashing Green=some traffic; Dark=no traffic,
possibly no connection
Transmit(Tx): Flashing or Steady Green=sending data
Receiver(Rx): Flashing or Steady Green=receiving data
Installation Instructions 579-953
Panel Data Sheet 4100ES S4100-0031
Reference 4010ES S4010-0004
11 11 •
a
��0 °
� �.�.. o
o r�°` � °�
° ��"a o � � Q
o �
o �
o p � Y`<
� ° o
o a o �
o �
0 0
0 p 0� O 9��e�s+ �
0 � � ����ae�
. pe�e��� �y e �
Be R%
.�� � `�� � , ;�"'��
I � �` e j �e�Q�e� .
Truelnsight Module on mounting � � ���,� `��ee �p � �
plate mounts on left side of o `'�e�ape�e o
4100ES/4100U bay bracket � o
0
Q � o� �
o � o
� � o� ��0
o �
--Q- ��
�
� �
� e o ���
\
�
� �
0
� �0�
TYCQ SIMPLEX,and the product names listed in this materzal are marks and/or registered marks.Unauthorized use is strictly prohibited.
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4100-0063-3 3/2013
www.simplexgrinnell.com
OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx Fire Alarm Control Panel Accessories
Listings* System Batteries, Sealed Lead-Acid; with Applications
Reference for Battery Cabinets, and Battery Cabinets with Charger
� J
---
Rechargeable, sealed lead-acid batteries: -- --
• Lead-calcium grid structure with immobilized _
electrolyte in absorbent separator �0000 _ „�
o�ooa
• Low maintenance with no need to add water
• Low self-discharge characteristics
• One-piece,high impact polystyrene cell cover with high
reliabiliry dua] seal construction
• UL 924 recognized pressure relief valves � ;@�•
Available in a variety of capacities:
• Batteries for internal mounring range from 6.2 Ah up to �
50 Ah,depending on control panel cabinet size
• Larger batteries, up to ll 0 Ah,mount in external battery
cabinets with models available with internal chargers
Battery cabinets with chargers:
• Battery cabinets with charger communicate with their
connected fire alarm control panel and are available for
4100ES/4010ES/4100U Series and 4010 Series panels __ _
� _ � . Compatible Sealed Lead-Acid Batteries can be
Installed Inside Fire Alarm Control Panel Cabinets
Simplex°rechargeable sealed-lead acid batteries provide
reliable and repeatable discharge and recharge
characteristics for use in fire alarm and other systems �
applications. They are designed with immobilized
electrolyte in an absorbent separator, allowing them to
provide rated capacity on the first cycle.
Because of their sealed construction,packaging is allowed
within the system electronics enclosure(see illustration
on page 2).When this is applicable,the quantity of
system cabinets and the battery wiring distances are both
minimized.Where required,external battery cabinets can Remote Battery Cabinets are Available for
be close-nippled to the control panel to house larger Larger Battery Requirements
batteries with battery chargers available in some battery
cabinet sizes.
� � • -�
Charging. These batteries are intended to be used with Shipping. Sealed lead-acid batteries are shipped via
compatible Simplex battery chargers. ground or sea transportation only. They are not shipped
via air.
Series Connections. These batteries are required to be
connected in series to produce 24 V system voltage. Disposal. Battery chemicals and materials can be
Battery sets must be of idenrical voltage,model number, recycled. Refer to information shipped with the battery or
appearance,and approximately the same date of on its case.Return to the battery manufacturer or to a
manufacture for proper operaYion. similarly qualified battery processing facility for proper
disposal.
Testing.Battery capacity testing is recommended to be
performed by using a sealed lead-acid battery tester � �{�-to details on page 4 and to the referer�ced individual product data
designed to withdraw a minimum of battery charge. The sheets fa-ageaicy�isting status of battery cabinets and ct,argers.TI-ie batteries
preferred tester applies a variety of amplitude and detailed in this cloa.iment rreet the requirerrents of UL,ULC,and Fac#ay
duration controlled test pulses that compares terminal Mutual for use with respective equipment battery chargers as listed on page 3.
voltage against those predicted for the specific battery �tad Your local Sirrplex product supp�ier fa-proper battery seledia,per
size. (Testing is available through your local Simplex systemrequire���ts.ListingsandapprovalsunderSirrplexTimeReca-der
product supplier.) Co.are the prc�erly of Tyco Fre Protedion Produds.
S2081-0006-20 1/2012
. .
Actual appearance will vary with battery size.
Sealed outer cover
Quick connect or post type terminal Vent hole
(type varies with battery size)� Potting material,black for
negative,red for positive
0 0 (polarity is also clearly
� marked with+and-)
�
Pressure relief valve
Innercover
Absorbent separator used
to immobilize electrolyte
Semi-permeable
Lead-calcium grids membrane separator
Cell group
Cell case(high impact
polystyrene)
• •
Capacity @ 20 Hour Height with Approximate
Battery Model Discharge Rate Width" Depth" Terminals Weight*
2081-9272 6.2 Ah 6-1/8"(156 mm) 2-5/8"(67 mm) 4"(102 mm) 5.75 Ibs(2.6 kg)
2081-9274 10 Ah 6"(153 mm) 4-1/16"(103 mm) 4"(102 mm) 9.2 Ibs(4.2 kg)
2081-9288 12.7 Ah 6"(153 mm) 4"(102 mm) 4"(102 mm) 9 Ibs(4.1 kg)
2081-9275 18 Ah 7-1/4"(184 mm) 3-3/8"(86 mm) 6-5/8"(168 mm) 14.3 Ibs(6.5 kg)
2081-9287 25 Ah 6-5/8"(168 mm) 5"(127 mm) 7"(178 mm) 19.4 Ibs(8.8 kg)
2081-9271
(rectangular case, 33 Ah 12-1/2"(318 mm) 3-3/8"(86 mm) 7-1/16"(179 mm) 26.6 Ibs(12.1 kg)
typically for service)
2081-9276
("square"case, 33 Ah 7-3/4"(197 mm) 5-1/4"(133 mm) 6-3/4"(171 mm) 26.5 Ibs(12 kg)
use for new)
2081-9296 50 Ah 9"(229 mm) 5-1/2"(140 mm) 8-7/8"(225 mm) 41.8 Ibs(19 kg)
2081-9279 110 Ah 11-3/16"(284 mm) 10-1/2"(267 mm) 9"(230 mm) 82 Lbs(37 kg)
� Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for
mounting compatibility.These batteries are 12 V each and series connected for 24 V system use.
NOTE: When wired in series for 24 V output,these batteries are to be of identical voltage,appearance,model number,and
approximately the same date of manufacture.
• •
Nominal Voltage Rating 12 Volts per battery
Discharge Rating 20 Hour Rate
Typical Charge/Discharge Cycles 100 to 150
Preferred Charge Temperature Range 60° F to 90° F(15.6°C to 32.2°C)
2 S2081-0006-20 1/2012
. . . . . � . . . .
NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information
Simplex Control Panel Model Series(see legend and notes below)
Battery Capacity
Model 4006& 4009 4100ES/ 4100&4120 4020
4003EC 4004R 4005 4008 (all models) 4010 4010ES 4100U (2,4 or 6-Unit) (2,4 or 6-Unit)
2081-9272 6.2 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
2081-9274 10 Ah �/ ./ �/ �/ �/ ./ �/ �/ �/ ./
2081-9288 12.7 Ah ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
2081-9275 18 Ah Ext Note 3 J Ext Ext Note 2 �/ �/ ./ ,/
2081-9287 25 Ah Ext Note 3 Ext Ext NA ✓ ✓ ✓ ✓ Ext
2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 �/ �/ Ext Note 4
rectangular
2081-9276 33 Ah Ext Note 3 Ext NA NA Note 3 ✓ ✓ ✓ Ext
"square"
2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext Ext
2081-9279 110 Ah Requires external battery cabinet,compatible with 4100ES,4010ES,4100,and 4120 Series only
✓ =Can be placed in the respective equipment cabinet
Ext=External battery cabinet is required, refer to selection chart on page 4
NA=Not applicable/not compatible
NOTES:
1. These batteries meet the requirements of UL, ULC,and Factory Mutual for use with respective equipment battery chargers
listed above. Contact your local Simplex product supplier for proper battery selection per system requirements.
2. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit.
3. Use 4081 series companion cabinet and charger, refer to page 4.
4. 4020 Cabinets will accommodate 2081-9271,33 Ah batteries, but will not allow bottom entry conduit.
5. Some control panel models are listed for battery replacement reference only.
6. For 2 bay international applications only,50 Ah batteries will fit in the cabinet.
. . . • . •
Battery Cabinets without Chargers (connects to charger in panel)
Battery
Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279
18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah
2081-9280 4100ES,4010ES, NA NA NA NA NA ✓
4100U, and 4100+
2081-9281 multiple �/ �/ ✓ J ✓ NA
2081-9282
4009-9801 multiple ✓ ✓"* NA NA NA NA
4009-9802 multiple ✓ NA ✓ NA NA NA
Battery Cabinets with Chargers
2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279
Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah
4081-9301 4004R and 4010 J ./ ✓ J J NA
4081-9302
4081-9306 4100ES,4010ES, NA NA NA NA �/ J
4081-9308 and 4100U
*Batteries smaller than those listed are normally mounted in the product cabinet
"25 Ah capacity was effective as of 7/2005.
✓=Can be placed in the respective equipment cabinet
NA=Not applicable/not compatible
3 S2081-0006-20 1/2012
. . .
Battery Cabinets Without Chargers; Shallow Design with Front Door
Model Color Listings Description Dimensions
2081-9281 Beige UL and 2'Unit,4100 style cabinet without charger;with locking 25-3/4"W x 20-3/4"H x 6-3/4"D
FM solid door and battery shelf, primarily for use with 50 Ah (654 mm x 527 mm x 171 mm)
2081-9282 Red batteries
4003-9860 Beige Multiple Intended for use with 4003EC systems,for up to 33 Ah 9-1/2"H x 24"W x 9"D
batteries(refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm)
4009-9801' Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4"W x 13-1/2"H x 5-3/4"D
FM batteries' with locking solid door and battery (413 mm x 343 mm x 146 mm)*
For up to 33 Ah harness;for close-nippled mounting to 25-3/4"W x 20-3/4"H x 4-1/8"D
4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm)
*Depth increased for 25 Ah batteries effective 7/2005.
Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems
(refer to data sheet S4081-0001)
Model Color Input Voltage Description Dimensions
4081-9301 Beige Battery cabinet with charger for the 4010 and
4004R fire alarm control panel;for up to 50 Ah
120 VAC batteries;with front door 22-1/2"W x16-3/4"H x 8-3/8"D
4081-9302 Red
Listings include:UL, ULC, FM, CSFM, and MEA �572 mm x 425 mm x 213 mm)
(NYC), see data sheet for details
Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers
(refer to data sheet S2081-0012)
Model& Color Cabinet Description Compatible Charger Description Dimensions
Listings Chargers
4010-9xxx 4010ES Main System Supply
Series (MSS)
4100-9xxx 4100ES/4100U System Power
Series Supplies(SPS)
Battery cabinet for 4100-5111
2081-9279, 110 Ah 4100-5112 4100ES/4100U Additional SPS
2081-9280 batteries; includes 4100-5113
Listings Red $0 A battery fuse, 4100-5125 4100ES/4100U Remote Power 26-1/2"W x 12"H x 12"D
include:UL terminals and 4100-5126 Supply(RPS) (673 mm x 305 mm x 305 mm)
and CSFM battery connection 4100-5127
cables; see data 4100-5120
sheet for details 4100-5121 4100ES/4100U TrueAlert
4100-5122 Addressable Power Supply(TPS)
4100-0104
4100-0114 4100 Legacy power supplies
4100-0124
4100ES/4010ES/4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems
and for other applications unable to use panel mounted power supply charger; referto data sheet S4081-0002)
Model Color Input Voltage Description Dimensions
Battery cabinet with charger for up to 110 Ah
4081-9306 Red 120 VAC batteries;
NOTE: Required for ULC listed charging of 27-7/8"W x 13-1/2"H x 14-5/8"D
220/230/240 VAC, 110 Ah batteries;Listings include:UL, ULC, FM, (708 mm x 343 mm x 371 mm)
4081-9308 Red multi-tapped CSFM, and MEA (NYC), see data sheet for
details
4100-9837 Green LED Power-on Indicator Kit, required for ULC listing,mounts above access panel using knockout provided
TYCO,SIMPLEX,and zhe product names Iisted in this material are marks and/a��-egistered marks.Unauthorized use is strictly pi�ohibited.
�oSim plEx Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S2081-0006-20 1/2012
www.simplexgrinnell.com
OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx System Accessories, LCD Annunciators
UL, ULC, CSFM Listed; 4606-9102 LCD Annunciator
FM, NYC Fire DeptApproved* for 4010ES Fire Alarm Control Panels
�
Remote LCD annunciator for use with Simplex°
model 4010ES fiire alarm control panels � �
LCD readout provides: =��TEM I`N�R�,�
!��:25:15 an�THU 02-AUG-1�
• Two lines of 40 characters each
• Wide viewing angle,super-twist design `#'�'
• LED backlighting � � sss�mp�
Control switches and status LEDs for:
• Alarm,Priority 2, Supervisory,or Trouble 4606-9102 LCD Annunciator
acknowledge(keyswitch access controlled)
• Alarm silence, System reset � � � � _�
• Three programmable control switches with yellow
LEDs and provisions for custom labeling Indications. Alarm, Prioriry 2, Supervisory,and Trouble
Additional features: condirions are also indicated by dedicated LEDs and a
• Information is transmitted over a single unshielded tione-alert audible indication.Each condition has a
dedicated acknowledge push-button switch that silences
twisted pair; separate wiring is required for 24 VDC the tone-alert but leaves the LED on until all conditions in
control panel power(see p. 3 for more information) that category are restored to normal.
• Tone-alert sounder provides local audible indication
Lamp and LCD are functionally tested each time the ACtivity Scrolling. Repeated operation of the
� keyswitch is turned on appropriate acknowledge switch will scroll the LCD
display showing activity in the sequence of occurrence.
• Mounts flush on standard 6-gang electrical box The internal tone-alert also sounds to indicate the
• Up to up to 20 internal and external card addresses per operation of any of the push-button switches.
4010ES fire alarm control panel
Mounting and trim options (ordered separately, � ' ' '
see page 3 for more details): Keyswitch Access.All switches on the annunciator are
• Surface mount box mode12975-9206 controlled by the"ENABLE"lceyswitch with a key that is
• Brushed stainless steel trim model 4603-9111 removable only in the disabled position.A brief
Lamp/LCD test is performed whenever the keyswitch is
� - . .
changed from enabled to disabled.
Enabled Operations. When enabled,notification
Local Annunciation.4606-9102 LCD Annunciator appliances can be deactivated by pressing the"ALARM
allows 4010ES fire alarm control panels to provide SILENCE"switch.Pressing the"SYSTEM RESET"
information and control switches at convenient locations switch restores the system to normal operation.When
away from the control paneL The LCD is an 80 character, system activity is normal,the LCD displays the time,
back-lit,alphanumeric display with information presented date, and"SYSTEM IS NORMAL."
in clear and descriptive English. Typical content includes:
point status(alarm,trouble,etc.),alarm type(smoke
detector,manual station,etc.),number of system alarms,
supervisory conditions,troubles, and custom location
labels up to 40 characters long.
* This product has been approved by the Califomia State Fre N�rshal(CSFN�pursuai�t to
�.011llllU111CatIO11S. D1t1 COri1ri1Uri1CahOriS T'eC1Ult'0 a Sediq�13144.1oftheCalifomiaHealtharidSaFetyCode.SeeCSFMListing
single unshielded twisted pair that supports other 73040026.0370faallavablevaluesarxl�orcondiUonsoaxemingrratenal preserrtedin
annunciators on the same communications channel. tr�s doa�r,�r,t.it�5 s�,t��to r��r�;r,at�«,,r��or,,arid pcssible canodlation.NYC Fre
Dept CCW#160�.Additia�al listirx�s rr�y be applicable;contact your local Sirrpleac product
supplier for the latest status.Listings and apprwals urxier Sirrplex Tirre Recorder Co.are
the prope�ty of Tyoo Fre Protedion Products.
S4606-0002-5 8/2012
. . .
Model Description
4606-9102 Remote LCD Annunciator with beige trim for use with 4010ES fire
alarm control panels
Refer to specifications on page 3
4603-9111 Brushed stainless steel trim option for additional details
2975-9206 Matching surface mount box; ivory finish
2081-9044 Overvoltage protector; required where annunciator communications and power wiring exits and enters a
building; refer to data sheet S2081-0016 for details
� . 1 . • 1 • • - . • . .
2 X 40 LCD READOUT,green LED
backlighted during normal conditions
and abnormal operating conditions SIX STATUS INDICATOR LEDs provide system status
indications in addition to LCD information;LEDs flash to
indicate the condition and then when acknowledged,
THREE PROGRAMMABLE(Yellow) remain on steady until reset; Fire Alarm and Priority 2
LEDs,each with pushbutton switch and Alarm are red;System Supervisory,System Trouble,
custom labeling pocket and Alarm Silenced are yellow;Power On is green
� �;Ja
DISPLAY TIME
'��Y'��TEt�! I'=� I�I��RC�I{�L displays time of last
; �°'�� ;. rr € 3f 1- �•EIEi �,'�; occurrenceofevent
1z'_r'::'_•_�z 1:_ � i-€_ �.�'-.,�_�_-
; list being displayed;
� or displays current
� time when viewing
� - system status
� �
�
, ,���; ` information
�
� `� f3 Sim lex
ALARM ACK/FIRE ALARM acknowledges
a Fire Alarm condition and silences the SYSTEM RESET restores
panel and all annunciator ton�alerts control panel to normal
CONTROL ENABLE when all alarmed inputs
ALARM ACK/PRIORITY 2 acknowiedges KEYSWITCH are returned to normal
a Priority 2 Alarm condition and silences controls all switch functions;
the panel and all annunciator tone-alerts key is removable only in
disabled position
SUPV ACK acknowledges System
Supervisory conditions and silences the ALARM SILENCE causes audible
panel and all annunciator tone-alerts notification appliances to be silenced;
used after evacuation is complete and
TROUBLE ACK acknowledges while alarm source is being investigated
System Troubles and silences the
panel and all annunciator tone-alerts
2 S4606-0002-5 8/2012
� . 1 . • 1 � � . • • - •
General Operating Specifications (refer to Installation Instructions 579-977 for additional information)
Voltage 18 to 32 VDC, system supplied
Normal Operating Current 110 mA(with LED backlighting on)
Battery Standby Current 65 mA(during battery backup, LED backlighting is turned off after 30 seconds
without switch activity)
Alarm Current 140 mA maximum (LED backlighting is on and tone-alert is sounding)
Operating Temperature Range 32°to 120° F (0°to 49° C)
Operating Humidity Range Up to 93% RH, non-condensing at 100° F(38° C)
Communications
RUI (Remote Unit Interface)external annunciator communications line SLC
For 4010ES Panels* Type (signaling line circuit)
Capacity Up to 20 total internal and external card addresses
Wiring Requirements
Standard Wiring Type Unshielded twisted pair(UTP), 18 AWG (0.82 mm2)for most applications, see below
Wiring Characteristics 0.58 uF (580 nF) maximum capacitance between conductors; 35 S2 maximum total
line resistance
1. Wiring that leaves the building.Also requires Isolated Loop Circuit Protectors on
each end, refer to data sheet S2081-0007 for 2081-9027 (200 mA), or
Wiring Applications S2081-0008 for 2081-9028(5 A)
RUI Data Requiring Shielded, 2. Wiring run in 500 ft(152 m)or more of conduit.
Twisted Pair(STP) 3. Wiring closely bundled with standard IDNet communications or TrueAlert
addressable communications (not required when run with IDNet+
communications).
Class B"T-Tap"wiring Up to 10,000 ft(3048 m)total wiring; up to 2500 ft(762 m)to farthest device
distance
Class X wiring distance Up to 2500 ft(762 m)
Power Wiring 18 to 12 AWG (0.82 mmZ to 3.31 mmZ)wires for 24 VDC system power
A dedicated earth ground connection to the electrical box is required for proper ESD
Earth Wiring and EMI protection; wire in accordance with NFPA 70 (National Electrical Code)
Article 250
Mounting Information
Trim Dimensions 4'h" H x 11 13��6"W(114 mm x 300 mm)
Assembly Depth � 5�6 (33 mm), 1 '/2"at terminal block location (38 mm)
Standard Trim Finish Steel, painted beige
4603-9111, Optional Trim Brushed stainless steel (ordered separately); supplied with both slotted and tamper
resistant screws
Boxes for Masonry boxes Six-gang box, RACO#965, 3'/z' (89 mm)deep or equal
Mounting Single gang boxes Six, single gang boxes, 3'/2'(89 mm)deep minimum, RACO#590 or equal
(supplied Conduit entrance is box dependent, refer to Installation Instructions 579-977 for
separately) Box selection note additional mounting information and conduit entry requirements
2975-9206, Surface Mount Box Option (ordered separately)
Dimensions 12"W x 4 5/8" H x 2 3/4" D (305 mm x 117 mm x 70 mm)
Finish Painted steel, ivory finish
* Refer to the 4010ES control panel data sheet for additional panel information.
3 S4606-0002-5 8/2012
. . . .
Note: Review box choice with assembly layout before selecting conduit
entrance location to allow easy access to terminals
Flush Mount Ganged Boxes:
Requires 6-gang box, 3-1/2" (89 mm) min.
depth, use (6) RACO#590 or equal ° o° ° o° ° o-° ° o° ° o° ° o°
(supplied separately)
Flush Mount Masonry Box: �
Use RACO#965, 3-1/2" (89 mm) deep
or equal (supplied separately) ° ° ° �-� �� ��
0 0 o a o o �
Surface Mount Box: � ,
Simplex model 2975-9206
2-3/4"deep(70 mm) 0
(ordered separately) o 0 0 0 0 0
O o o O
LCD Annunciator Assembly—.
Trim plate • v
��
Terminal block O o 0
access at rear of
assembly, this side
O O Q�m�ex
•
Interconnection Wiring Notes:
1. Communications require 18 to 12 AWG unshielded twisted pair.
2. Power requires two, 18 to 12 AWG wires for 24 VDC system power,
plus Earth Ground to each electrical box.
3. Refer to Installation Instructions 579-977 for additional wiring
specifications.
---- -
-
�
� ; To other RUI devices
-
� ���g '� �
--
– �s�
_0110��II����9��IIII���IIII��D�II�QR���IR����������Q���01���0�l��0
s��uu��u5uo�uruuuo�uioiu�io�u�uu�u�. ,� �; �
4010ES Fire Alarm Control Panel 4606-9102 LCD Annunciators
TYCO,SIMPLEX,ancf the product names listed in this naaterial ar�e»�arkr and/or registered marks.Unauthorized use is sdrictly prohibited.National Glectrical Code and NFPA ai'e
registered tr-ademarl�s of the National Fire Pr�otecrion Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4606-0002-5 8/2012
www.simplexgrinnell.com
OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx Multi-Application Peripherals
UL, ULC, CSFM Listed; FMApproved; IDNet or MAPNET II Communicating Devices
MEA (NYC) Acceptance* Addressable Manual Stations
� � ���'� '�;��)�
Individually addressable manual fire alarm �-
stations with:
• Power and data supplied via lDNet ar MAPNET II � �� � � � ��' � _c �
addressable communications using a single wire pair �
• O eration that com lies with ADA re uirements
P P q
• The NO GRIP Single Action Station and Retrofit Kit � � ,
are available with a more easily operated pull lever for
applications where anticipated users may find the 4099-9001 4099-9020 4099-9805
standard station lever difficult to activate Single action NO GRIP NO GRIP
• Pull lever that protrudes when alarmed
Single action Retrofit kit
• Break-rod supplied(use is optional) �
• Models are available with single or double action I� �)� � �,� ����
(breakglass or push)operation -
• UL listed to Standard 38 � `
Compatible with the following Simplex°control I
panels: � ��
i!
• Model Series 4100ES,4010ES,4008,4010,4100U,
4020,4100, and 4120 fire alarm control panels 0 0 0
equipped with either IDNet or MAPNET TI
communications 4099-9002 4099-9003 With 2099-9828
Model Series 2120 Communicating Device Breakglass Push Institutional
� Cover kit
Transponders(CDTs)equipped with MAPNET II
communications • • ' •
Compact construction: Activation of the 4099-9001 single action manual station
• Electronics module enclosure minimizes dust requires a firm downward pull to activate the alarm switch.
in6ltration CompleYing the action breaks an internal plastic break-rod
• Allows mounting in standard elec�rical boxes (visible below the pull lever,use is optional). The use of a
• Screw terminals for wiring connections break-rod can be a deterrent to vandalism without
interfering with the minimum pull requirements needed for
Tamper resistant reset key lock(keyed same as easy activation. The pull lever latches into the alarm
Simplex fire alarm cabinets) position and remains extended out of the housing to provide
Multiple mounting options: a visible indication.
• Surface or semi-flush with standard boxes or matching Single Action NO GRIP Station 4099-9020. For
Simplex boxes applicarions such as California Building Code,Title 24,
• Flush mount adapter kit which requires"Controls and operating mechanisms shall
Adapters are available far retrofitting to commonly be operable with one hand and shall not require tight
� available existing boxes grasping,pinching or twisting of the wrisY'the model
4099-9020 station provides a more easily operated pull
� - • . lever compared to standard stations. Retrofit of existing
stations is available using the 4099-9805 Retrofit lcit.
The Simplex addressable manual station combines the Double Action Stations (Breakglass)require the
familiar Simplex manual starion housing with a compact operatar to strike tbe front mounted hammer to break the
communication module that is easily installed to satisfy g�ass and expose the recessed pull lever. The pull lever then
demanding applications.Its integral individual operates as a single action station.
addressable module(IAM)constantly monitors status and
communicates changes to the connected control panel via Double Action Stations (Push Type)require that a
IDNet or MAPNET II communications wiring. spring loaded interference plate(marked PUSH)be pushed
back to access the pull lever of the single action station.
" Refertopage2faspeaficmodel Iistings.Thisproducthasbeenapprovedbythe Station reset requires the use of a key to reset the manual
Califomia State Fre Marshal(CSFN�pursuant to Sedion 13144.1 of the Califomia HealYh station lever and deactivate the alarm switch. (If the break-
arxJ Safety Caie.See CSFM Listing 7150-002G:224 for allauable values and/a oonditions
corioerning rrateri�prese�,ted in tnis doa,rr�r,t.�t is subjed to re-e�n;nati«,,revision, rod is used, it must be replaced.)
�,d���e�r,o�i��or,.a�c�afor�-atyo�r�,Nvor�o�rt�»�r,co�e�,�ia�r,�- Station testin is erformed b h sical activation ofthe
NEA3Cr93E.Pdditional listings rrey be�plic�ble;comacc ya,�i«�s��prod�.t 9 P Y P Y
�,���-fo�-tr,eiat��tstat�.u����,da�waisu�s���r��«d��.�e pulllever. Electricaltestingcanbealsoperformedby
tr,eprop�tyo�TyooFreProcectia,�roducts. unlocking the station housing to activate the alarm switch.
S4099-0001-9 5/2012
� . . . . - . . . .
Addressable Manual Stations, Red Housing with White Letters and White Pull Lever
Model Description Housing Pull Lever Listings
4099-9001 Single action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA
4099-9001CB Single action, Bilingual English and French FEU FIRE TIREZ PULL
ULC, FM
4099-9001CF Single action, French ALARME FEU ABAISSEZ
4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA
4099-9003 Double action, Push operation, English
4099-9020 Single action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM
Accessories
Model Description
2975-9178 Surface mount steel box, red
Refer to page 3 for dimensions
2975-9022 Cast aluminum surface mount box, red
2099-9813 Semi-flush trim plate for double gang switch box, red
Typically for retrofit, refer to page 4
2099-9814 Surface trim plate for Wiremold box V5744-2, red
2099-9819 Flush mount adapter kit, black
Refer to page 4 for details
2099-9820 Flush mount adapter kit, beige
2099-9803 Replacement breakglass
2099-9804 Replacement break-rod
2099-9828 Institutional cover kit for field installation on 4099-9001
4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions
579-1007 for details
• - . • . • • � • .�• • • . •
Power and Communications IDNet or MAPNET II communications, 1 address per station
Address Means DIP switch, 8 position
Wire Connections Screw terminal for in/out wiring,for 18 to 14 AWG wire
UL Listed Temperature Range 32°to 120° F(0°to 49°C)intended for indoor operation
Humidity Range Up to 93% RH at 100° F(38° F)
Housing Color Red with white raised lettering
Material Housing and pull lever are Lexan polycarbonate or equal
Pull Lever Color White with red raised lettering
Housing Dimensions 5"H x 3-3/4"W x 1"D(127 mm x 95 mm x 25 mm)
� • • . . - . . .
Single Gang Box Mount 4"Square Box Mount
Single gang box,2-1/2"deep 4"(102 mm)square box,2-1/8"(54 mm)minimum
(64 mm),RACO#500 or equal depth,RACO#231 or equal(supplied by others)
(supplied by others) �
L� L� L�
_ o o Mount flush or with �
° a ° �� 1/16"(2 mm)
maximum extension
� ° DO NOT RECESS 4"Square box
�� � � o �� with cover plate
� � �
� �
C> � i
o '
i
—� i
O �
i
i
Station �
F�� \O � side view i
�
Single gang cover plate,3/4" ;
(19 mm)extension,RACO#773
--------
�� �� or equal(supplied by others)
1 Single gang
box outline
Wall surface�
Semi-Flush Mount Side View
�+Simplex
2 S4099-0001-9 5/2012
� . . . . . . .
2975-9178 Box 2975-9022 Cast Box
Preferred Mounting.For 5-3/16"H x 4"W x 2-3/16"D 5"H x 3-7/8"W x 2-3/16"D
surface mounting of these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm)
(ordered separately) (ordered separately)
addressable manual stations,the
preferred electrical boxes are �
shown in the illustration to the
right.
0 0 0 0
Additional Mounting Knockouts located
Reference. Refer to page 4 for top and bottom
Wiremold box mounting
compatibility.
� FIRE ��)�I
0
0
PULL DOVUV
1 Access for 3/4"threaded
5.� conduit located top and bottom
(127 mm)
fi Simplex �
1"(25.4 mm)
�-3-3/4"(95 mm)-► �
4099 Series Addressable Manual Station
• • - � - � • • •
Refer to NFPA 72,the National Fire
Alarm and Signaling Code,and all
1-1/4" applicable local codes for complete
�3� 2 mm) Simplex 2975-9178 box requirements for manual stations. The
Field wiring I�-� (shown for reference)
(shown for reference) � following summarizes the basic
requirements.
1. Stations shall be located in the
normal path of exit and distributed
Address setting under in the protected area such that they
resealable label(accessible are unobstructed and readily
with cover open) �► ■
2 5�$„ accessible.
(67 mm) 2. Mounting shall be with the
operable part not less than 42 in
Station cover (1.07 m)and not more than 48 in
hinges open for (1.22 m)above floar level.
installation access �
3. At least one station shall be
Switch wiring provided on each floor.Additional
(prewired) stations shall be provided to obtain
a travel distance not more than
200 ft(6l m)to the nearest station
from any point in the building.
4. When manual station coverage
appears limited in any way,
additional stations should be
instal led.
3 S4099-0001-9 5/2012
� . . . . - . � . . . . . . .
For retrofit and new
installations,additional o 0
Wiremold
compatible mounting boxes �o �� receptacle box
and the required adapter plates 2099-9814 Surface trim model V5744-2
are shown in the illustrarion to for wiremoid box (supp�ied by
5-1/8"H x 5"W others)
the right. (130 mm x 127 mm)
o O
o � o Two gang switch box,each
3"H x 2"W x 2-3/4"D
� ��� (76mmx51 mmx70mm)
(supplied by others)
4099-90011DNet ° � �
addressable station �� ��
C �
O
U U
2099-9813 Semi-flush trim for 2 gang o � � o
switch box,6"H x 4-1/2"W
(152mmx114mm)
' • • . � - • • • • •
Flush mount adapter kit
2099-9819,Black
2099-9820,Beige�
Box must be recessed into wall
� 1"to 1-1/8"(25.4 mm to 29 mm)
� (�
��'�; I
� � �
8�� - ��
(203 mm) � �
Hole cutout must be a
minimum of 6"H by 5"W �
6�� (152 mm by 127 mm)
�
(152 �-
mm) ��
� �
�
4-11/16"(119 mm)
square box,2-1/8"
(54 mm)minimum
Wall depth(by others)
-� 4-3/4"(121 mm) -= surface��
. 6-3/4"(171 mm)
Front View Side View
TYCO,SIMPLEX,and the product names listed in[his material are marks and/or eegi.rtered marks.Unau[horized u.re is steictly�ro{tibited.N!'PA 72 and National I'ire
Alarm and Srgnaling Code are trademarks of�the Nafional Fire Proteciion Association(NFPA).Lexan is a trademark of the General F,lech-ic Co. Wiremold zs a trademark of
the Wirernold Company.
�05 i m p I Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4099-0001-9 5/2012
www.simplexgrinnell.com
�O 20/2 Tyco Fire 73 okection Aoducts.Ap nghts reserved.A!!spec�cations and other info�mukon shown were ewrent as of documenk revision date and are subject to change without r2otice.
�oSimplEx TrueAlarm Analog Sensing
UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors — Photoelectric
MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories
�
TrueAlarm analog sensing provides:
• Digital transmission of analog sensor values via IDNet �
or MAPNET lI two-wire communications
For use with the following Simplex°products:
• 4100ES,4100U,4010ES,and 40]0 Series control
panels; and 4008 Series control panels with reduced 1 1
feature set(refer to data sheet 54008-0001 for details) —
• 4020,4100,and 4120 Series control panels,Universal
Transponders,and 2120 TrueAlarm CDTs equipped 4098-9714 TrueAlarm Photoelectric
for MAPNET II operation Sensor Mounted in Base
Fire alarm control panel provides:
• Peak value logging allowing accurate analysis of each � ' • •
sensor for individual sensitivity selection
• Sensitivity monitoring satisfying NFPA 72 sensitivity Digital Communication of Analog Sensing.
testing requirements;automatic individual sensor TrueAlarm analog sensors provide an analog
calibration check verifies sensor integrity measurement digitally communicated to the host control
• Automatic environmental compensation,multi-stage panel using Simplex addressable communications.At the
control panel,the data is analyzed and an average value is
alarm operation, and display of sensitivity directly in determined and stored.An alarm or other abnormal
percent per foot condition is determined by comparing the sensor's present
• Ability to display and print detailed sensor value against its average value and time.
information in plain English language
Intelligent Data Evaluation.Monitoring each sensor's
PhotoeleCtric smoke sensors provide: average value provides a continuously shifting reference
• Seven levels of sensitivity from 0.2%to 3.7% point. This software filtering process compensates for
(refer to addirional informarion on page 3) environmental factors(dust,dirt,etc.)and component
Heat sensors provide: aging,providing an accurate reference for evaluating new
• Fixed temperature sensing activiry.With this filtering,there is a significant reduction
• Rate-of-rise temperature sensing in the probability of false or nuisance alarms caused by
shifts in sensitivity,either up or down.
• Utility temperature sensing
• Listed to UL 521 and ULC-S530 Control Panel Selection.Peak activity per sensor is
stored to assist in evaluaring specific locarions. The alarm
General features: set point for each TrueAlarm sensor is determined at the
• Listed to UL 268 and ULC-S529 host control panel, selectable as more or less sensitive as
• Louvered smoke sensor design enhances smoke the individual application requires.
capture by direcring flow to chamber; entrance areas Timed/Multi-Stage Selection. Sensor alarm set points
are minimally visible when ceiling mounted can be programmed for timed automatic sensitivity
• Designed for EMI compatibiliry selection(such as more sensitive at night,less sensitive
• Magnetic test feature is provided during day).Control panel programming can also provide
• Optional accessories include remote LED alarm multi-stage operation per sensor.For example,a 0.2%
indicator and output relays level may cause a warning to prompt investigation while a
Additional base reference: 2.5°/o level may initiate an alarm.
• For isolator bases,refer to data sheet 54098-0025 Sensor Alarm and Trouble LED Indication.Each
• For sounder bases,refer to data sheet 54098-0028 sensor base's LED pulses to indicate communications
with the panel.If the control panel determines a sensor is
• For photo/heat sensors,refer to data sheet S4098-0024 in alarm,or is dirry ar has some other type of trouble,the
(single address)and 54098-0033 (dual address) details are annunciated at the control panel and that sensor
' m��xnd�r,��,a�o�ed eytne c,��fo�„�a st�te F�nro�r,�(csFn���,t to base's LED will be turned on steadily. During a system
sect�a,�s�aa.�ortnecai�fa„�a�tnandsarerycode.seecsFrvtust��s alarm the control anel will control the LEDs such that
7272-0026:218,7271-0026231,7270-0026216,and 7300-0026217 fa allo�ble values � p
arxuor oonditions ooncernir,g rreterial preserted in tnis doaamer,t.acoepted tor use—atyof an LED indicating a trouble will return to pulsing to help
NewYalcDepartmentofBuildings—NEA3.5-93EPdditiaial listingsrrnybeapplicable, identify the alarmed sensors.
contact your local Sirrplex product supplier for the latest status.Listirx�s and appra�als under
Slrrplex Trre Reca-der Co.are the property of Tyco Rre Rotedion Raluds.
S4098-0019-15 4/2013
TrueAlarm Sensor Bases and Accessories ■ - . .
. TrueAlarm sensor bases contain integral addressable
electronics that constantly monitor the status of the
Base mounted address selection: detachable photoelectric or heat sensors. Each sensor's
• Address remains with its programmed location output is digitized and transmitted to the system fire alarm
• Accessible from front(DIP switch under sensor) control panel every four seconds.
General features: Since TrueAlarm sensors use the same base,different
• Automatic identificarion provides default sensiriviry sensor types can be easily interchanged to meet specific
when substituting sensor types location requirements. This feature also allows intentional
• Integral red LED far power-on(pulsing),or alarm or sensor substitution during building construction.When
trouble(steady on) conditions are temporarily dusty, instead of covering the
• Locking anti-tamper design mounts on standard outlet smoke sensors(causing them to be disabled),heat sensors
box may be installed without reprogramming the control
panel. Although tbe control panel will indicate an
• Magnetically operated functional test incorrect sensar type,the heat sensor will operate at a
� default sensitivity providing heat detection for building
protection at that location.
4098-9792, Standard sensor base
4098-9789, Sensor base with wired connections for: � �
• 2098-9808 Remote LED alarm indiCator or 4098-9822 Electrical Box Requirements:(boxes are by others)
relay(unsupervised)
Without relav:4"octagonal or 4"square,1-1/2"deep;
4098-9791,Sensor base with supervised relay driver single gang,2��deep
output(not compatible with 2120 CDT): w�tn relav:a"octagonal or 4"square,1-1/2"deep,
• Relay operation is programmable and can be manually witn i-�/2"extension ring
operated from control panel a^(102 mm)Square Box a^(102 mm)Octagonal Box
• Use with remote mount 2098-9737 relay surface mount�efe�ence
• Also includes wired connections for remote LED alarm
indicator or 4098-9822 relay �` � � �
� ' U � u �J
• • • •
2098-9737, Remote or local mount supervised relay: �-�i2��(38 mm)
minimum box depth
• DPDT contaCts for resistive/suppressed loads,power Flush mount reference,mount even with final
limited Cating of 3 A@ 28 VDC;non-power limited surface,or with up to 1/4"(6.4 mm)maximum recess
rating of 3 A@ 120 VAC(requires external 24 VDC ' �
;2098-9737 Relay(mounts in 4098-9822 Relay(mounts �
COI� pOWei� ;base electrical box or remotely) in base electrical box) �
4098-9822, LED Annunciation Relay: ; �
� ;
• Activates when base LED is on steady,indicating local � ;
alarm or trouble ' �
� ;
• DPDT contacts for resistive/suppressed loads,power � ;
limited rating of 2 A@ 28 VDC;non-power limited � ;
rating of 1/2 A@ 120 VAC,(requires external 24 VDC ; �
COIl pOW2T� ; Relay Size: 2-1/2"X 1-1/2"X 1"(375 cubic inches)
; (64mmX38mmX25.4mm) �
4098-9832,Adapter plate: ; �
, NOTE:Review total wire count,wire size,and accessories �
• Required for surfaCe or semi-flush mounting to � being wired to determine required box volume. ;
4"square electrical box and for surface mounting to '---------------------------------------------%
4"octagonal box �� 6-3/8"(162 mm) �
• Can be used for cosmetic retrofitting to existing 6-3/8"
dlameteT'baSe pl'OdUCt - � 4098-9832 Adapter Plate,re�c uired for
2098-9808, Remote red LED Alarm ��4�� mounting to surface mounted boxes
� (6.4 mm) and 4"sauare flush box
Indicator:
• Mounts on single gang box
�. 4-7/8"(124 mm) -�
ALARM
(shown in illustration to right) �o �5/�s"
(24 mm) p
}3�m�� TrueAlarm Bases
4098-9789,-9791,&-9792
�
2 S4098-0019-15 4/2013
TrueAlarm Sensors
� , . . �
Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate
Interchangeable mounting compensated, fixed temperature sensing, selectable with
EMI/RFI shielded electronics or without rate-of-rise temperature sensing.Due to its
Heat sensors: small thermal mass,the sensor accurately and quickly
• Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire
sensing with or without rate-of-rise operation alarm control panel.
• Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the
control panel for either 15°F(8.3°C)or 20°F(11.1°C)
Fixed Temp. UL&ULC FM Spacing,Either Fixed per minute. Fixed temperature sensing is independent of
Setting Spacing Temperature Setting
rate-of-rise sensing and programmable to operate at
135°F 60 ft x 60 ft �0 ft x 20 ft(6.1 m)for fixed 135°F(572°C)or 155°F(68°C).In a slow developing
(57.2°C) (18.3 m) temperature only;RTI=Quick
5o ft x 5o ft(�5.z m)for fixed fire,the temperature may not increase rapidly enough to
155°F 4o ft x 40 ft temperature with either rate-of-rise operate the rate-of-rise feature.However,an alarm will be
(ss°C) (�2.2 m) selection;RTI=ultra Fast initiated when the temperature reaches its rated fixed
Smoke Sensors: temperature setting.
• Photoelech-ic technology sensing TrueAlarm heat sensors can be programmed as a utility
• 360°smoke entry for optimum response device to monitor for temperature extremes in the range
from 32°F to 155°F(0° C to 68°C).This feature can
• Built-in insect screens provide freeze warnings or alert to HVAC system
problems.Refer to specific panels for availabiliry.
� 1 • ' • • • - •
-7/8"(124 mm)
TrueAlarm photoelectric sensors use a stable,pulsed
infrared LED light source and a silicon photodiode ���—�E�status indicator
receiver to provide consistent and accurate low power 2-3/8"
smoke sensing. Seven levels of sensitivity are available (60 mm)
for each individual sensor,ranging from 0.2%to 3.7%per
foot of smoke obscuration. Sensitivities of 0.2%,0.5%,
and 1%are for special applications in clean areas.
Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o.
Sensitivity is selected and monitored at the fire alarm 4098-9733 Heat Sensor with Base
control panel.*
The sensor head design provides 360° smoke entry for WARNING: In most fires, hazardous levels of smoke
optimum response to smoke from any direction. Due to its and toxic gas can build up before a heat detection
photoelectric operation,air velocity is not normally a device would initiate an alarm. In cases where Life
factor,except for impact on area smoke flow. Safety is a factor,the use of smoke detection is highly
recommended.
-. 4-7/8"(124 mm) -
II��LED status indicator . � � �
2-1/8"
(54 mm) Sensor locations should be determined only after careful
consideration of the physical layout and contents of the
area to be protected.Refer to NFPA 72,the National Fire
Alarm and Signaling Code. On smooth ceilings, smoke
4098-9714 Photoelectric Sensor with Base sensor spacing of 30 ft(9.1 m)may be used as a guide.*
* For detailed application information including sensitivity
selection, refer to Installation Instructions 574-709.
3 S4098-0019-15 4/2013
- � � . . . . . .
TrueAlarm Sensor Bases
(Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information)
Model Description Compatibility Mounting Requirements
4098-9792 Standard Sensor Base,no options Sensors 4098-9714 and 4098-9733 4"octagonal or 4"square box, 1-1/2"min.
depth;or single gang box,2"min.depth
Sensor Base with connections for Sensors 4098-9714 and 4098-9733 4"octagonal or 4"square box
4098-9789 Remote LED Alarm Indicator or 2098-9808 remote LED alarm
Unsupervised Relay indicator or 4098-9822 relay Note:Box depth requirements depend on
Sensors 4098-9714 and 4098-9733 total wire count and wire size,refer to
Sensor Base with connections for accessories list below for reference.
Supervised Remote Relay and 2098-9737 remote relay(supervised)
4098-9791** connections for Remote Alarm **NOTE:4098-9791 is NOT compatible
2098-9808 remote alarm indicator or With the 2120 CDT
Indicator or Unsupervised Relay 4098-9822 relay(unsupervised)
TrueAlarm Sensors
Model Description Compatibility Mounting Requirements
4098-9714 Photoelectric Smoke Sensor Bases 4098-9792,4098-9789,
4098-9733 Heat Sensor and 4098-9791 Refer to base requirements
TrueAlarm Sensor/Base Accessories
Model Description Compatibility Mounting Requirements
Remote Mounting requires 4"octagonal or
2098-9737 Supervised Relay,mounts remote For use with 4098-9791 base 4"square box, 1-1/2"minimum depth
or in base electrical box Base Mounting requires 4"octagonal box,
2-1/8"deep with 1-1/2"extension ring
2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2"minimum depth
on single gang stainless steel plate
Relay,tracks base LED status Bases 4098-9789 and 4098-9791
4098-9822 (unsupervised,mounts only in base 4"octagonal box,2-1/8"deep with 1-1/2"
electrical box) extension ring
Required for surtace or semi-flush
4098-9832 Adapter Plate Bases 4098-9792,-9789,&-9791 mounted 4"square box and for surface
mounted 4"octagonal box
. - . •
General Operating Specifications
Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400µA typical,
1 address per base
Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mmZ to 2.08 mm2)
Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current
Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG(0.82 mm2)
UL Listed Temperature Range 32°to 100°F(0°to 38°C)
with 4098-9733 32°to 122°F(0°to 50°C)
Operating Temperature Range
with 4098-9714 15°to 122°F(-9°to 50°C)
Humidity Range 10 to 95%RH
Smoke Sensor 4098-9714, Air velocity=0-4000 ft/min(0-1220 m/min)
Ambient Ratings Photoelectric Sensor
Housing Color Frost White
4098-9791 Base With Supervised Remote Relay 2098-9737(see page 2 for contact ratings)
Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC)
Supervisory Current 270µA,from 24 VDC supply
Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply
4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings)
Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC)
Supervisory Current Supplied from communications
Alarm Current 13 mA from separate 24 VDC supply
TYCO,SIMPLEX,and zhe product names listed ln this material are marks and/a�registered marks.Unauthorized use is strzctly pi�ohibited.NFPA 72 and Nationa7 Fire Alarm and
Signaling Code ar�e trademarlrs of the Nalzona[Fire Protecfion Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0019-15 4/2013
www.simplexgrinnell.com
OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx Multi-Point Peripherals
UL, ULC, CSFM Listed; TrueAlarm CO Sensor Bases for Smoke, Heat, and
FMApproved* Photo/Heat Sensors using IDNet Communications
�
TrueAlarm addressable CO sensor bases contain
a carbon monoxide (CO) sensing module
providing both CO toxic gas monitoring and
enhanced fire detection: `
• Far use with 4100ES,4100U or 4010ES fire alarm
control panels(4100U requires software revision 12.05 �'' '�
or higher)
• CO sensor bases support(and require)a TrueAlarm
photoelectric,photo/heat or heat sensor(ordered TrueAlarm CO Sensor Base with Sounder
separately) (shown with 4098-9754 Photo/Heat Sensor)
• Mode14098-9797 provides standard features, model
4098-9798 also provides a piezoelectric sounder � _�
• CO sensor bases are multi-point devices,consume only
one TDNet address,and receive both communications 4100ES/4100U/4010ES Control Panel operation
and sensor power from the TDNet channel (the sounder summary:
base requires separate 24 VDC system power or NAC • CO sensor data is stored and analyzed at the panel;a
connection) new CO Service Report provides easy information
• Listed to UL 268,Smoke Detectors for Fire Alarm access(see sample on page 3)
Signaling Systems and UL 2075, Gas and Uapor . Five(5)year end of life status indication with CO
Detectors and Sensors;allowing systems to be listed to sensor expiration notices occurring within l2 months
Standard 2034,Single and Multiple Station Carbon and within 6 months,allowing service replacement
Monoxide Alanns planning
• Listed by ULC to CSA 6.19-01 Residential Carbon • Analog sensor informarion is digitally transmitted to
Monoxide Alarming Devices the host control panel via lDNet communications for
• Three types of CO influenced operation are available; processing to evaluate and tracic status
UL 2034 CO alarm detection;UL 2075 CO(OSHA) • Carbon monoxide concentration in ppm(parts per
level monitoring for ventilation control; and million)is available for viewing from the panel user
multi-criteria fire sensor analysis with algorithms that interface
combines optical and CO gas monitoring information . For OSHA compliant CO gas sensing,CO condition
Operation of a CO sensor base with a level may be programmed by concentration(must be
photoelectric or a photo/heat sensor allows: above 30 ppm)
• Independent sensor operation or selectable multi-sensor General fieatures:
modes of False Alarm Reduction or Faster Detection
• Operation of a CO sensor base with heat sensor provides
• False Alarm Reduction analyzes CO and photoelectric dual independent sensor operation
sensor informarion together to provide a sophisticated New CO test mode allows functional testing of each
rejection of non-fire conditions normally troublesome as �
false alarms(steam,dust,aerosols, etc.) sensar technology including the CO sensor
• Faster Detection(increased sensitivity)algorithm • Optional accessories include remote alarm LED,alarm
analyzes CO and photoelectric sensor information to relay,and mounting adapter plate
allow the presence of CO to implement an increased • Designed for EMI compatibility
photoelectric sensitivity for high value locations • Provides magnetic test
(museums,electrical equipment rooms, etc.) CO sensor element is easily replaced when end of
Sounder base operation details: service life is reached:
• When connected to a panel NAC through the 4905-9835 . Access to CO sensor replacement cartridge(CORC,
Temporal Code Module,the sounder base can provide 4098-9746)requires removal of interchangeable sensor
temporal code 3 (TC3)far fire,or temporal code 4 head providing tamper monitaring(sensor removal
(TC4)for toxic carbon monoxide alarms causes a trouble condition)
• 4905-9835 module may also be used to code other
(non-fire)dedicated carbon monoxide notification • -rns�roductnas�r,a�ro�nytt,�carrorr�astateFren�rsr,�(cs�vrj�rs�,ar,t
appliances(refer to data sheet 54905-0006) to sea�a,�s�aa.�o�tne cai�ro�,�a�tn a�,d sarety coae.see csFnn�st��
• Sounder can be manuall activated from the anel ����forallwaadevaluesand/aoonditirnscaicemingrr�terialpresentedin
Y P tns doa ir�t.�stirx�and�pp-ova�s urx�Sirrpleac rrre Re�rder co.are the
• Sounder operation is also listed to UL 464 as an audible r�a�v��m���n�i�,�m��.
notification appliance
S4098-0041-7 4/2013
• • - � - � • • • � - - � • � - • • '•
Carbon monoxide (CO) is an odorless,colorless, Nuisance Alarm Reduction Details.For applications
tasteless gas produced by the incomplete combustion of of anticipated nuisance alarm conditions,photoelectric
heating fuels such as wood,coal,heating oil,and natural sensitivity is nonnally selected for 3.7%/ft smoke
gas. CO is also a byproduct of many inaterials experiencing obscuration. However,the addition of CO sensing allows
unintentional fire or even incipient fire conditions. the host control panel to apply software verification similar
Monitoring of CO levels can warn of physically harmful to the rimed alarm verification feature often used with
concentrations,however, sensing of CO levels below the conventional smoke detection.
harmful level can also provide improved understanding of Faster Fire Detection.For applications where faster
incipient fire conditions when evaluated in combination response to incipient ar slow building fires is desired and
with photoelectric fire sensor information from the same environment appropriate,the Faster Fire Detection mode
locarion. correlates the outputs of the CO sensor and the photoelectric
Simplex°CO sensor bases combine an electrolytic CO sensor to provide increased sensitivity. This mode provides
sensing module with a TrueAlarm analog sensor to provide earlier detection compared to a standard sensitive
a single multiple sensing assembly using one system photoelectric sensor setting,and also provides more false
address. The CO sensor can be enabled/disabled,used in alarm reducrion compared to using a sensitive setting in an
LED/Switch modes and custom control, and can be made area not normally considered appropriate.
public for communication across a fire alarm Network Faster Fire Detection Details. TrueAlarm photoelectric
CO sensor operation is similar to other TrueAlarm sensors can be selected to be as sensitive as 0.2%/ft
sensors(photoelectric or heat). It provides current analog obscuration for applications evaluated as appropriate to that
values,average analog value,"No Answer"troubles, level. However,if the environment is not suitable for that
"Wrong Device"troubles,over threshold,concentration in sensitivity level,the Faster Fire Detecrion mode allows the
ppm,and monitors far the presence of the CO sensor. Base photoelectric sensor to be selected as a"standard"2.5%/ft
mounted address selection allows the address to remain obscuration,but with the presence of a significant level of
with its location when the sensor is removed for service or CO,the combination of CO and photo sensing input can
type change.Address access is from the front,under the allow an equivalent sensitivity approaching 0.5%/ft
removable sensor. An integral red LED indicates power-on obscurarion. The host control panel tracks two photoelectric
by pulsing,or alarm or trouble when steady on,and also sensitivities,the one selected for photoelectric operation
provides test mode status(see page 3). Detailed status is only(typically 2.5%),and the CO correlation sensitivity
available at the fire alarm control panel. that it adjusts depending on the amount of CO present.
• • � - - � • � - • • • • • - •
Toxic Gas Sensing, UL 2034/UL 2075.For CO toxic Smoke sensor features include: sensitivity
gas detection,the bases provide toxic gas sensing to the monitoring sarisfying NFPA 72 sensitivity testing
UL 2034 and UL 2075 standards. Toxic gas sensing may be requirements,automatic individual sensor calibration
selected at the same time as any of the combined CO photo checking to verify sensor integriry,automaric
fire detection modes are selected. environmental compensarion,available multi-stage alarm
Toxic Gas Sensing, OSHA Compliant.For OSHA operation,display of sensitivity directly in percent per foot,
compliant gas sensing,the desired threshold level (above monitoring of peak activity per sensor,alarm set point,and
30 ppm)is selected at the control panel as required for the time of day ar multi-stage alarm selection.
application,rypically for ventilation control. Refer to page 3 Sensor Alarm and Trouble LED Indications.The
for additional OSHA CO monitoring information. sensor base LED pulses to indicate communications with
Enhanced Fire Sensing.Each sensor provides an the paneL If a sensor is in alarm,or has a trouble condition,
analog measurement digitally communicated to the control the status is annunciated at the control panel and that base
panel for analysis.At the panel,these analog values are LED will turn on steady. During a system alarm,the panel
used separately,or combined,to evaluate for conditions will control LEDs such that a trouble indication will return
indicative of fire,incipient fire,excessive heat,and freeze to pulsing to help idenrify the sensors in alarm.
warning.For fire,the addition of a CO sensor provides two Reported CO Sensor troubles are: Disabled,Almost
new selectable modes of operation:Nuisance Alarm Expired 12 Months,Almost Expired 6 Months,Expired
Reduction Mode and Faster Fire Detection.These two (End of Life), Short,and Sensor Missing/Failed.
modes were developed using the results of extensive testing Trouble Details."Almost Expired"is similar to the
of actual fires performed under a wide variety of conditions. �°Almost Dirry"trouble for a photoelectric sensor.
(Refer to page 4 for additional operation mode options.) "Expired"trouble is similar to the"Dirty"�rouble for a
Nuisance Alarm Reduction Mode allows the host TrueAlarm photoelectric sensor. CO sensor technology
control panel to combine photoelectric sensor input and CO does not support automatic sensitivity testing and drift
sensor level input to reduce false alarms caused by non-fire compensation as is available with a photoelectric sensor.
conditions.Non-fire conditions can be steam from End of useful CO sensor life is based upon a set 5 year
bathroom showers,particles from dusty environments, operational lifetime,tracked by date code built into the CO
aerosols from personal care products,tobacco smoke, sensar module electronics. Although the CO sensor wi11
cooking smoke, or other similar conditions. continue to function after the 5 year expired trouble is
indicated,replacement is required to ensure proper
detection accuracy.
2 S4098-0041-7 4/2013
• • � • - • • '• ` •
Panel Test Mode. To facilitate functional tesring of the 2098-9808, Remote red LED
CO sensor,a new test mode is available in the host control Alarm Indicator mounts on a �
panel.In this mode,the CO sensor,and installed heat or single gang box to provide status
smoke sensor can be easily functionally tested. indications where the sensor
Panel Test Mode Details. When in the CO test mode, locarion may not be readily a�ARM
the internal multiple sensor analysis algorithms are disabled visible. (See illustration to right.) �
allowing each sensor to be quickly tested either individually 4098-9822, LED Annunciation
or simultaneously,depending on the test equipment used. Relay activates when base LED is
CO testing can be performed using a Solo Model 332 on steady,indicating a local alarm �Simplex
aerosol dispenser(or equal). (Testing is available through or trouble. Contacts are DPDT,
your local authorized Simplex product supplier.)The base rated 2 A@ 30 VDC; 1/2 A@ �
LED will display steady ON when individual sensors are 120 VAC for transient suppressed
activated during test. Refer to the Application Reference loads(requires externa124 VDC
section for more information. coil power).
OSHA CO monitoring. For OSHA compliant gas ' � � - •
sensing(i.e.parking garages and workplace spaces with Determine sensor locations after careful consideration of the
combustion type equipment)control panel software
supports the internal programming command"ANALOG Physical layout and contents of the area to be protected.
COMPARE"to provide comparisons of CO points. For For fire alarm applications:
example,in a custom control equation to turn on a fan or . Refer to NFPA 72,the National Fire Alarm Code
vent. "If the CO toxic gas is 50 ppm(or is greater or less . On smooth ceilings,smoke sensor spacing of 30 ft
than X ppm)"then turn on control point. The valid
concentration range for the opcode is 30 to 563 ppm. (9.1 m)may be used as a guide.
For detailed application information:
Multi-Point AIIoCation.The host panel requires three(3) . Refer to 4098 Detectors, Sensors, and Bases Application
points per CO sensor base with the 4098-9754 multi-sensor, Manual,Part Number 574-709.
and two(2)points for the other sensors.Depending on CO
sensor base and sensor choice,up to seven(7)points can be For toxic gas sensor placement and mounting:
made public to a connected Simplex Fire Alarm Network • Refer to NFPA 720,StandaNd for the Installation of
Each CO sensor base uses a single address with each of the Carbon Monoxide(CO) Warning Equipment in Dwelling
individual points appearing as"sub-points"layered Units
underneath(such as 1-1-0, 1-1-1, 1-1-2, ....1-1-6). . Sensors may be either wall or ceiling mounted
(Additional multi-point allocation detail is described in
reference data sheet S�4090-0011.) • Per NFPA 720, Section 5.1 (2005 edition):
5.1.1 A carbon monoxide alarm or detector shall be
CO Sensor Base Power Requirements.Power for the centrally located outside of each separate sleeping area
standard CO sensor base is provided by IDNet in the immediate vicinity of the bedrooms.
communications.No additional wiring is required for 5.1.2 Each alarm or detectar shall be located on the wall,
upgrading of existing installed Tr�ueAlarm sensor bases. CO ceiling,or other location as specified in the installation
sensor sounder bases do require system supplied separate instructions that accompany the unit.
24 VDC(or NAC)wiring,the same as the standard sounder
base.
� • . .
TrueAlarm CO Service Reports (sample below)contain information on the CO sensors programmed in the panel
displaying pertinent data such as current concentration value in ppm,End of Life date,and current state.This report allows
determinarion of which sensors will require attention.
Service Port Page 1
REPORT 6 : TrueAlarm CO Report 12:34:56am WED 10-APR-13
-----------------------------------------------------------------------------------------------
Channel 1 (M1)
Zone Current End of
Name CUSTOM LABEL Value Life Date State
-----------------------------------------------------------------------------------------------
M1-1-2 Conference Room 17 CO Toxic Gas 457PPM 01-APR-18 PRI
M1-2-2 Boiler Room CO Toxic Gas OPPM Ol-APR-18 NOR
TRUE ALARM CO REPORT COMPLETED
Press RETURN for next Screen OR CTRL-X to abort
3 S4098-0041-7 4/2013
- � � . . . . . .
TrueAlarm CO Sensor Base
Model Description
4098-9797 CO Base,Standard operation
Select TrueAlarm sensor from list below
4098-9798 CO Base with Sounder
TrueAlarm Sensors, select one per CO Sensor Base
Model Description
4098-9714 Photoelectric Smoke Sensor
4098-9754 Multi-Sensor Photoelectric and Heat Sensing Refer to selection table below for available operation
modes
4098-9733 Heat Sensor
CO Base Replacement CO Cartridge and Accessories (ordered separately as required)
Model Description
4098-9746 CO Replacement Cartridge(CORC)
Solo 332 Aerosol Dispenser,suitable for larger diameter detectors;can be used for CO or smoke testing
Solo C3 CO Aerosol Canister(case of 12)
Model Description Mounting Requirements
4098-9832 Adapter Plate, required for surface mounted 4"electrical boxes Refer to page 6, mounting reference
2098-9808 Choose Remote red LED Alarm Indicator on single gang Single gang box, 1-1/2"minimum depth
stainless steel plate
one if
4098-9822 required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2"
mounted only in base electrical box) extension on 4"square or octagonal box)
• • • • - • • • • • •
M Operational Mode Choices" (✓ =operation selected)
Sensor Choice �
d False Alarm Faster TrueSense Photo Heat Utility lon Fire CO Toxic CO
e Reduction Detection Photo/Heat Fire Fire*' Temp. Gast Firett
Photoelectric 1 ✓ — — — — — — option option
Smoke Sensor
4098-9714 2 — ✓ — option — — — option option
Photo/Heat 3 ✓ — — — option option — option option
Multi-Sensor 4 — ✓ — option option option — option option
4098-9754 5 — ./ option option option option option
Heat Sensor 6 — — — — ✓ option — option —
4098-9733 � _ — — — option J — option —
" NOTE: Duct detection modes are not applicable and are not available. Each CO base and sensor counts as multiple points
against panel point capacity depending on the operations selected at the 4100ES/4100U/4010ES control panel, refer to data
sheet S4090-0011 for additional multi-point allocation detail.
"Heat Fire Mode is 135° F or 155° F,fixed or rate-of-rise.
t CO Toxic Gas operation is selectable as: Supervisory(which is NOT recommended if communicated off-site), Priority 2(preferred
if communicated off-site),or Utility.
tt CO fire detection mode can be selected only when used with a photoelectric smoke detection sensor set for fire detection mode.
4 S4098-0041-7 4/2013
. 1 1 � � � � � � � � �
Sealed against rear air flow entry TrueAlarm multi-sensors combines the performances of
Electronics are EMI/RFI shielded TrueAlarm photoelectric smoke sensing with TrueAlarm
thermal sensing to provide both features in a single
Heat sensing: assembly. Each sensing element provides data for
• Selectable rate compensated,fixed temperature evaluation at the fire alarm control panel where the
sensing with or without rate-of-rise operation following four independent detection modes are
• Rated spacing distance between sensors: evaluated:
• Fixed temperature heat detection
Fixed Temp. UL&ULC FM Spacing,Either Fixed . Rate-of-rise heat detection
Setting Spacing Temperature Setting
2o ft x 2o rt(s.� m)tor fixed • TrueAlarm photoelectric smoke detection
135°F 60 ft x 60 ft • And TrueSense correlation detection
(57.2°C) (18.3 m) temperature only;RTI=Quick
5o ft x 5o ft(15.2 m)for fixed TrueSense analysis correlates both thermal activity
155°F 40 ft x 40 ft temperature with either rate-of-rise
(ss°c) (�2.2 m) seiection;RTI=Ultra Fast and smoke activity at a single multi-sensor location
using an extensively tested covariance relationship.As a
Smoke Sensors: result,TrueSense detection improves response to
• Photoelectnc technology sensing conditions indicative of faster acting,hot flaming fires
when compared to the response of either photoelectric
• 360°smoke entry for optimum response smoke activity or thermal activity alone.
• Built-in insect screens
, � • • • �
' � ' � ' ' • • - - • TrueAlarm heat sensors are self-restoring and provide rate
compensated, fixed temperature sensing, selectable with
TrueAlarm photoelectric sensors use a stable,pulsed or without rate-of-rise temperature sensing. Due to its
infrared LED light source and a silicon photodiode small thermal mass,the sensor accurately and quickly
receiver to provide consistent and accurate low power measures the local temperature for analysis at the fire
smoke sensing. Seven levels of sensitiviry are available alarm control panel.
far each individual sensor,ranging from 0.2%to 3.7%per
foot of smoke obscuration. Sensitivities of 0.2%,0.5% Rate-of-rise temperature detection is selectable at the
and l%are for special applications in clean areas. control panel for either I S°F(8.3°C)or 20°F(1 l.1° C)
Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o. per minute. Fixed temperature sensing is independent of
Sensirivity is selected and monitored at the fire alarm rate-of-rise sensing and programmable to operate at
control panel.* 135°F(57.2°C)or 155°F(68°C).In a slow developing
fire,the temperature may not increase rapidly enough to
The sensor head design provides 360° smoke entry far operate the rate-of-rise feature.However,an alarm will be
optimum smoke response.Due to its photoelectric initiated when the temperature reaches its rated fixed
operation, air velocity is not normally a factor,except for temperature setting.
impact on area smoke flow. TrueAlarm heat sensors can be programmed as a utility
device to monitor for temperature extremes in the range
= sai�s°��sa mm> 'I from 32°F to 155°F(0° C to 68°C).This feature can
2-5/16°(58 mm) provide freeze warnings or alert to HVAC system
LED status indicator problems.
i
� � = 6-7/16"(164 mm) –
I, � �
2-7/16" � I
(62 mm)
�
1 � __ _-----—
Output louvers on �
� Sounder Base extend �
CO sensor Thermistor guard� from front and side 2-9/16" 1
housing (Multi-Sensor only) (65 mm) �
Dimension and Feature Reference, Photoelectric
or Multi-Sensor on CO Sensor Base
t— _
' • • • 4098-9733 Heat Sensor with CO Sensor Base
Sensor locations should be determined only after carefizl (with CO Sensor Housing facing forward)
consideration of the physical layout and contents of the WARNING: In most fires, hazardous levels of smoke
area to be protected. Refer to NFPA 72,the National Fire and toxic gas can build up before a heat detection
AlaNm and Signaling Code. On smooth ceilings, smoke device would initiate an alarm. In cases where Life
sensor spacing of 30 ft(9.1 m)may be used as a guide.* Safety is a factor,the use of smoke detection is highly
recommended.
* For detailed application information including sensitivity
selection, refer to Installation Instructions 574-709.
5 S4098-0041-7 4/2013
.
Electrical Box Requirements: (boxes are by others)
Without relav:4"octagonal or 4"square, 1-1/2"deep;single gang,2"deep
With relav:4"octagonal or4"square, 1-1/2"deep,with 1-1/2"extension ring
4"(102 mm)Square Box 4"(102 mm)Octagonal Box
Surface mount reference
� 1-1/2"(38 mm) � � �1
�minimum box depth � + ���
Flush mount reference, mount even with final
surface,or with up to 1/4"(6.4 mm)maximum recess
-----------------------------
; O�tional 4098-9822 Relav �
� ' (Mounts in base electrical box �
� ,
Note: Single gang ; and requires additional �
adapter plate(RACO ; volume,see notes below) '
�
�
No.787 or equal)is � ;
required when using 4" � �
square box(by others) � �
� Relay size: �
; 2-1/2"X 1-1/2"X 1" �
� ; (64mmX38mmX �
; 25.4 mm),3.75 cubic inches �
�----------------------------�
4098-9832 Adapter Plate, required for mounting
6-3/8"Dia. �� �to surface mounted boxes(mounts inverted)
x 1/4"thick
�= 6-7/16"(164 mm) -�
�
1-1/8"
(29 mm)
♦
CO sensor assembly
(CORC)shaded for reference LED status
indicator
(Photoelectric sensor shown for reference)
NOTES:
1. Review actual wire size,wire count, box type,and whether 4098-9822 relay is used before determining box
size.
2. Mounting to flush mounted box also fits single gang handy box,2-1/8"(51 mm)deep if wiring allows. (Not
applicable if 4098-9822 relay is used.)
3. For surface mounted boxes, use 4"square box with single gang adapter plate(RACO No. 787 or equal, by
others)or 4"octagonal box, both require 4098-9832 Adapter Plate.
4. When 4098-9822 relay is used, mount relay in electrical box and use 1-1/2"extension ring(by others)on 4"
square or octagonal box of 1-1/2"or 2-1/8"depth as required.
5. Refer to sensor base Installation Instructions 574-707 for additional information.
6. Refer to CORC Replacement Instructions 579-791 for CO cartridge installation and replacement.
6 S4098-0041-7 4/2013
. - , .
General Operating Specifications
IDNet Communications and Sensor Supervisory Power 24-40 VDC w/data,400µA typical, 1 address per base,supplied by control
panel
Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2)
Current 1 mA typical supplied from communications, no impact to alarm current
Remote LED Alarm Indicator
LED Connections Color coded wire leads, 18 AWG(0.82 mm2)
UL Listed Temperature Range 32° F to 100° F(0°C to 38°C)
Operating with 4098-9733 32° F to 122° F(0°C to 50°C)
Temperature Range with 4098-9714 or 4098-9754 15° F to 122° F(-9°C to 50°C)
Humidity Range 15 to 95% RH
CO Sensor Base Photoelectric Sensor 4098-9714
Air Velocity Ratings and Multi-Sensor 4098-9754 Air velocity=0-1000 ft/min(0-305 m/min)
perSensor
Housing Color Frost White
Sounder Operation
Sounder Voltage 18 to 32 VDC from steady external source or from NAC
Alarm Current(Sounder On) 17 mA @ 24 VDC,24 mA maximum @ 32 VDC
88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling
Sounder Output Appliance; UL Standard 268, Smoke Detectors for Fire Protective
Signaling Systems and CSA 6.19-01
Supervised Select for continuous 24 VDC power, loss of power is communicated to
Sounder Power Supervision panel
(Selectable) Select when connected to NAC for sounder power, NAC provides
Unsupervised
supervision
NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized
pattern(Temporal or March Time,etc.)controlled by the NAC control
Standards Reference for CO Monitoring
Concentration Alarm Window
70±5 ppm 60 to 240 minutes
Requirements Reference for Response Time 150±5 ppm 10 to 50 minutes
UL 2034 and CSA 6.19-01
400±10 ppm 4 to 15 minutes
False Alarm 30±3 ppm No Alarm for 30 days
Resistance 70±5 ppm No Alarm for 60 minutes
UL 2075 Reference, Commercial OSHA Type For operations required at lower concentrations than those of UL 2034,
Operation such as start ventilation after 5 minutes at 25 to 35 ppm and to alarm at a
reading higher than that range, but lower than UL 2034 allows
4098-9822 Unsupervised Relay Option
Externally Supplied Relay Voltage 18-32 VDC,steady source recommended (wires to remote LED leads)
Alarm Current 13 mA from separate 24 VDC supply
Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC
resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC
Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base
� • • . . .
Product Data Sheet
Temporal Code 4 Module S4905-0006
Standard Bases S4098-0019
Isolator Bases S4098-0025
Standard Sounder Base S4098-0028
TrueSense Multi-Sensor S4098-9024
Dual Address Multi-Sensor S4098-0033
7 S4098-0041-7 4/2013
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0041-7 4/2013
www.simplexgrinnell.com
�2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice.
�oSimplEx Non-Addressable Peripherals
UL, ULC, CSFM Listed; 4905-9835 Temporal Code 4
FM Approved* Module for CO Gas Alarm Notification
�
Provides Temporal Code 4 (TC4) NAC (Notification
Appliance Circuit) control for Carbon Monoxide � �
(CO) gas warning:
• The TC4 CO gas warning is a repeated sequence of four o OO � tt � O o
cycles of 100 msec on with 100 msec off,followed by
5 seconds off per NFPA 720,Standard for the �
Installa2ion of Carbon Monoxide(CO) Warning , `"�;_;,;•..
Equipment in Dwelling Units ' � '
• Compatible appliances includes: CO Sounder Base
4098-9798,4901-9820 Horn(set for free-run),and 4903 0 0
Series 4-wire AN appliances horn input(not compatible ��������
with SmartSync horn control appliances) � �
Compatible Simplex°equipment NAC sources:
• 4100ES,4100U,or 4010ES NAC outputs 4905-9835 Temporal Code 4 Module
• 4009 IDNet NAC Extender NAC outputs (shown approximately 1/2 size)
• Each module requires an input NAC that powers the 3A
rated output NAC far control of comparible audible � - . . • -�
notification appliances only(notforstrobes)
Three selectable operation modes: CO gas alarm, or fire alarm.Use of the 4905-9835
• Synchronized operation allows a separate and Temporal Code 4 Module allows Yhe NFPA 720 Temporal
dedicated control NAC to both activate and synchronize Code 4 signal to be generated using a standard Steady On
audible appliance NAC input.Under the fire alarm panel's
the Temporal Code 4 output timing of up to 20, control,the audible notification signal can be selected for a
4905-9835 modules conventional fire pulse pattern for a fire alarm condition,or
• Unsynchronized operation also allows the separate and the Tempora] Code 4 pattern can be acrivated for a CO gas
dedicated control NAC to activate the Temporal Code 4 alarm condition.
output timing of Lip to 20,4905-9835 modules,but
without synchronizarion between the modules
. - . .
• Stand-Alone operation allows the input NAC in alarm
to activate Tempora] Code 4 timing for NACs dedicated For 24 VDC NACs, up to 3 A
for CO gas alarm;no fire alarm signals are available,no maximum, limited by input NAC
control NAC is used NAC Control rating;for control of audible
• For both Synchronized and Unsynchronized modes, notification appliances compatible
when the control NAC is off,the module output NACs with TC4 code pulse duty cycle
will follow the fire alarm signals of the input NAC Input NAC Current Supervisory current=0.18 mA
• NOTE: For TC4 output,both the input NACs and the Requirements Alarm current= 15 mA
control NACs requires a Steady On signal Control NAC Current Supervisory current=0 mA
CompBCt, S@81@d COIIStI'UCt1011: Requirements Alarm current=3 mA
• Mounts in standard 4"square electrical box Mounting Distance Mount close-nippled,20 ft(6 m)
• Screw terminals for wiring connections to input NAC Source maximum distance
Listed to UL Standard 864 and ULC Standard S527 Screw terminals for in/out wiring,
Wire Connections 18 to 12 AWG wire
(0.82 to 3.31 mm2)
, . � � Dimensions 4"x 4'/8"x 1 '/8'D
CO gas alarm warnings are required to be different from (102 mm x 105 mm x 35 mm)
fire alarm warnings. In the event of a CO gas alarm,the Mounting Plate Sheet metal,galvanized
presence of a Temporal Code 4 audible signal pattern Material
identifies the type of condition to the responders to assist in Temperature Range 32°to 120° F(0°to 49°C),
determining the proper actions to be taken. intended for indoor operation
Humidity Range Up to 93°/o RH at 100° F(38°C)
`This product has been approved by the Califania State Fre Nl�rshal(CSFM)pursuarit to
Section 13144.1 of the Califania Fie�th and SaFety Code.See CSFM Listing 730Q0026:328
fa allava�le v�ues arxUor conditia�s oor�cerning rreterial presented in this doaarrent.This
proaud was r,ot accepcea by n�EA(rwc)�ot aoa irr�rrt revisia,ckk�te.acaitla,al�istings
rrgy be applicade;caitact your local Sirrplex product supplier for the latest status.Listings
arid approvals urid�Sirrplex Time Reca-der Co.are the properly of Tyoo Rre Prdedion
Products.
S4905-0006-5 4/2013
. .
4905-9835 Temporal Code 4(TC4)Module
__--- -----___ Dedicated control NAC
I 4098-9798 CO 4901-9820 Horn,4903 Series 4-wire A/V horn,
-�__°9= o? � Sensor Sounder or other compatible(not SmartSync control)
� �I Base* 24 VDC audible notification appliances
NAC input to TC4 `� 0 1 _ /
" Module,3 A maximum � f
I ����
iiiiimii���ini�iiipiiiiiiiiiiiiiiiiiiiii� TC4 NAC output,3 A maximum
namiiiii�ii�muim�iiiaiiiiiiiiiiiiiiiiiiiiiioo
Dedicated control NAC to the next Temporal
Fire Alarm Control Panel Code 4 Module, up to 20 total maximum; requires
(4100ES shown for reference) � �' end-of-line resistor per source NAC requirements
IDNet or RUI Communications
per system requirements =____�_____ ° °
______=_=_' —� Appliance NACs require
a end-of-line resistor per
� �o�,� source NAC requirements
4009 IDNet NAC Extender(shown, uses IDNet �Note: IDNet communications wiring
communications)or Remote 4100ES MINIPLEX (not shown)is required to connect
transponder with NACs(uses RUI communications) to each 4098-9798 CO Sensor
SounderBase
. .
Mounting Box(supplied separately),4"square
(102 mm), minimum depth=2-1/8"(54 mm), ���
RACO 232 or equal �-��
>
�
0 0
, �
o �,
� 0 ���,�� � �� 0
����b�q� o �
�.Et; �"1Wqjl
.,F i�.,y.
§`I :P� _
I 0�
,i
0
/
� 4"square cover plate, RACO 752
or equal (supplied separately)
� . • .
Document Description Document Description
579-840 Installation Instructions S4010-0004 4010ES Control Panel
S4098-0041 CO Sensor Base data sheet S4901-0010 4901-9820 Horns
S4100-0031 4100ES Basic Reference S4903-0011 4903 Series 4-wire A/Vs
TYCO,SIMPLEX,and the product nantes listed in ehis malerial are marks and/or registered marks.Unauthonzed iuce is strictly prohibited.NFPA is a trademark of the Natioixa/Fire
Protection Aa�sociation.
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4905-0006-5 4/2013
www.simplexgrinnell.com
�2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice.
�oSimplEx TrueAlarm Analog Sensing
UL, ULC, CSFM Listed; FM Approved; Sounder Base 4098-9794 for use with
MEA (NYC) Acceptance* TrueAlarm Photoelectric and Heat Sensors
�
Modular TrueAlarm sensor base with built-in
electronic alarm sounder:
• Piezoelectric sounder provides high output(88 dBA)
with low current requirements(20 mA)
• For use with interchangeable TrueAlarm photoelectric
or heat sensors(ardered separately) --`�
Sounder operation details: TrueAlarm Photoelectric Sensor Mounted in
• Powered from 24 VDC or from a compatible Sounder Base 4098-9794
Notification Appliance Circuit(NAC)
• Synchronized via communications or by the NAC, if ' ' ' - • • • � ' • •
NAC powered**
• Sounder can be manually activated from the control panel Sounder bases combine an audible notification appliance
• Sensor and sounder operation is listed to UL Standard 268 and a TrueAlarm analog sensor to provide:
• Sounder operation is also listed to UL Standard 464 Digital Communication of Analog Sensing.
as an audible notification appliance Sensors provide an analog measurement that is digitally
TrueAlarm analog sensing operation: communicated to the control panel where it is analyzed
• Analog sensor information is digitally communicated and an average value is determined and stared.An alarm
to the control panel via lDNet or MAPNET II or other abnormal condition is determined by comparing
two-wire communications the sensor's present value against its average value.
• Sensor information is processed by the control panel Intelligent Data Evaluation.Monitoring each sensor's
to determine sensor status average value provides a software filtering averaging
For use with the following Simplex°produCts: process that compensates for environmental factors(dust,
• 4]OOES,401 OES,4010, and 4]OOU Series control dirt,etc.)and component aging,providing an accurate
panels; and 4008 Series control panels with reduced reference for evaluating new activity. The result is a
feature set(refer to data sheet 54008-0001 far details) significant reduction in the probability of false or
• 4020,4100,and 4120 Series control panels,and nuisance alarms caused by shifts in sensitiviry,either up
Universal Transponders equipped for MAPNET II or down.
operation Control Panel Selection.Peak activity per sensor is
General features: stored to assist in evaluating specific locarions. The alarm
• Louvered smoke sensor design enhances smoke set point for each TrueAlarm sensor is determined at the
capture by directing flow to chamber; entrance areas control panel,selectable as more or less sensitive as the
are minimally visible when ceiling mounted individual application requires.
• Designed for EMI compatibiliry
Magnetic test feature is provided Timed/Multi-Stage Selection.Alarm set points can be
• Optional accessories include remote LED alarm programmed for timed automaric sensitiviry selection
indicator and output relays (such as more sensitive at night,less sensitive during
day). Control panel programming can also provide
Additional base reference: multi-stage operation per sensor.For example,a 0.2%
• For standard bases,refer to data sheet S4098-0019 level may cause a warning to prompt investigation while a
• For isolator bases,refer to data sheet S4098-0025 2.5%level may initiate an alarm.
• For photo/heat sensors,refer to data sheet 54098-0024 Sensor Alarm and Trouble LED Indication.Each
(single address)and S4098-0033 (dual address) sensor base's LED pulses to indicate communications
with the panel.If the con�rol panel determines that a
' Thisproducthasbcenapprwedtr�theC�'rfariaStateFreN�rsh�(CSFN�pursuanttoSeUion sensor is in alarm, or that it is dirty or has some other type
�3�`�a.�o�u�c��o�„�a�m�,ds�avc«�.s�c�t��ti���a�o"�s2���,d of trouble,the details are annunciated at the control panel
rn�-0ozs:zs�ra�a�io�eva��,esana�a-o�tia,s�;r�rr�eria�p-�a,rea�ntns and that sensor base's LED will be turned on steadil
cbaarrerit.F�ed for use—Qty of Ne�Yaic De{�er4rerrt of�ailc�ngs—NFP3�r�iE Pdc�tia�al 5'•
IisCingsrraybeapplicable,oorrtacl�rourlocalSlrrplacprak�ctsupplierfa-thel�estsYahs.Listings During a system alarm,the control panel will control the
andap�xwalsux�-S�rrpexrmeR�rderco.aretne�xo�erryorTycoFreProtectia, LEDs such that an LED indicatin a trouble will return to
Products. g
""Tdalqua�tityofsande�-l�ase,a2ilablefaoodingonthesanecormliticationsd�r�elrreyvary Pulsing to help identify the alarmed sensors.
�th pand application and av�labiliry of I�po.n�-.REfer to spedfic aritrd par�l requirerrents.
S4098-0028-7 4/2013
� . . . . . - . .
Base mounted address selection allows the address
to remain with its programmed location when the sensor
is removed for service or type change. Access is from the Electrical Box Requirements:(boxes are by others)
front under the removable SensOr. Without relav:4"octagonal or 4"square, 1-1/2"deep;single gang,
2"deep
Automatic sensor type identification provides
With relav:4"octagonal or 4"square,1-1/2"deep,with 1-1/2"
default sensitiviry when substituting sensor types. extension ring
Different sensor types can be easily interchanged to meet a°(102 mm)Square Box a°(102 mm)Octagonal Box
specific location requirements. This feature also allows Surface mount reference
intentional sensar substitution during building -
construction. When conditions are temporarily dusty, � ,
instead of covering the smolce sensors(causing them to be �-�/2°(3s mm� �1
�minimum box depth � �� �
disabled),heat sensors may be installed without
reprogramming the control panel.
Flush mount reference,mount even with final
Illt@gl'al 1'@d LED indicates power-on by pulsing,or surface,or with up to 1/4"(6.4 mm)maximum recess
alarm or trouble when steady on.The exact status is
annunciated at the fire alarm control panel. �
�
; Optional 4098-9822 Relav �
Fire alarm control panel provides: � ; (Mounts in base electrical box ;
Note:Single gang ; and requires additional �
• Peak value logging allowing accurate analysis of each adapter plate(RACO ; volume,see notes below) �
sensar for individual sensitivity selection No.787 or equal)is � �
• Sensihvity monitoring satisfying NFPA 72 sensitivity required when using 4" ; �
square box(by others) � Relay size: �
testing requirements;automatic individual sensor � ,
calibration check verifies sensor inte rit ; 2-v2"x�-v2"x��� �
g y O ; (64mmX38mmX �
• Automatic environmental compensation,multi-stage ; 25.4 mm),3.75 cubic inches �
�----------------------------
alarm operation,and display of sensitiviry directly in
6-3/8"Dia.
pel'Cent peT fOOt x 1/4".thick 4098-9832 Adapter Plate,reauired for mounting
• Ability to display and print detailed sensor \�` �to surface mounted boxes(mounts inverted)
information in plain English language
�. 6-7/16"(164 mm)�
� • �
1-1/8„
4098-9822, LED Annunciation Relay activates when (2s mm
base LED is on steady, indicating a local alarm or trouble. �
Contacts are DPDT,rated 2 A@ 30 VDC; 1/2 A@ �
120 VAC for transient suppressed loads(requires external �ED status sound output�ouvers
24 VDC COt�poWeT�. indicator extend from front to side
2098-9808, Remote red LED Alarm Indicator mounts on
a single gang box to provide status indications where the
sensor location may not be readily visible.
(Photoelectric sensor shown for reference)
� NOTES:
1. Review actual wire size,wire count,box type,and whether
4098-9822 relay is used before determining box size.
ALARM 2. Mounting to flush mounted box also fits single gang handy box,
� 2-1/8"(51 mm)deep if wiring allows.(Not applicable if 4098-9822
relay is used.)
3. For surface mounted boxes,use 4"square box with single gang
adapter plate(RACO No.787 or equal,by others)or 4"octagonal
435implex box,both reauire 4098-9832 Adapter Plate.
4. When 4098-9822 relay is used,mount relay in electrical box and use
�l 1-1/2"extension ring(by others)on 4"square or octagonal box of
1-1/2"or 2-1/8"depth as required.
5.Refer to Installation Instructions 574-707 for additional information.
2098-9808 Remote LED Alarm Indicator
2 S4098-0028-7 4/2013
� � • • �
, � • • �
Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate
Electronics are EMI/RFI shielded compensated, fixed temperature sensing, selectable with
or without rate-of-rise temperature sensing. Due to its
Heat sensors: small thermal mass,the sensor accurately and quickly
• Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire
sensing with or without rate-of-rise operarion alarm control panel.
• Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the
Fixed Temp. UL&ULC FM Spacing,Either Fixed Control panel for either 15°F(8.3°C)or 20°F(ll.l° C�
Setting Spacing Temperature Setting per minute. Fixed temperature sensing is independent of
135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fxed rate-of-rise sensing and programmable to operate at
(57.2°C) (18.3 m) temperature only;RTI=ciuick 135°F(57.2°C)or 155°F(68°C).In a slow developing
5o ft x 50�t(�52 m�tor fixed fire,the temperature may not increase rapidly enough to
155°F 40 ft x 40 ft temperature with either rate-of-rise
(ss°c) (�2.2 m) selection;RTI=Ultra Fast operate the rate-of-rise feature. However,an alarm will be
initiated when the temperature reaches its rated fixed
Smoke Sensors: temperature setting.
• Photoelech-ic technology sensing TrueAlarm heat sensors can be programmed as a urility
• 360°smoke entry for optimum response device to monitor for temperature extremes in the range
• Built-in insect screens from 32°F to 155°F(0° C to 68°C).This feature can
provide freeze warnings or alert to HVAC system
problems.Refer to specific panels for availabiliry.
� 1 • ' ' • • - • I
I� 6-7/16"(164 mm)- ►I
Tr�ieAlarm photoelectric sensors use a stable,pulsed
infrared LED light source and a silicon photodiode
receiver to provide consistent and accurate low power
smoke sensing. Seven levels of sensitivity are available 2-9/16°
for each individual sensor,ranging from 0.2%to 3.7%per (65 mm)
foot of smoke obscuration. Sensitivities of 0.2%,0.5%,
and 1%are for special applications in clean areas. �
Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7%. - -
Sensitivity is selected and monitored at the fire alarm
control panel.* 4098-9733 Heat Sensor with 4098-9794 Sounder Base
The sensor head design provides 360° smolce entry for
optimum smoke response.Due to its photoelectric WARNING: In most fires, hazardous levels of smoke
operation, air velocity is not normally a factor,except far and toxic gas can build up before a heat detection
impact on area smoke flow. device would initiate an alarm. In cases where Life
Safety is a factor,the use of smoke detection is highly
= 6-7/16"(164 mm) - C@COITIITI@IIC�@C�.
* I i
` � � •
� Sensor locations should be determined after careful
2-5i16" consideration of the physical layout and contents of the
�5a mm� area to be protected. Refer to NFPA 72,the National Fire
� _ Alarm and Signaling Code. On smooth ceilings, smoke
sensor spacing of 30 ft(9.1 m)may be used as a guide.
For detailed application information,refer to 4098
4098-9714 Photoelectric Sensor with Sounder Base Detectors, Sensors, and Bases Application Manual,Part
Number 574-709.*
* For detailed application information including sensitivity
selection, refer to Installation Instructions 574-709.
3 S4098-0028-7 4/2013
- � � . . . . . .
TrueAlarm Sounder Base*
Model Description Compatibility Mounting Requirements
Sounder Base with connections Sensors:4098-9714 and 4098-9733
4098-9794 for Remote LED Alarm Indicator Refer to page 2,mounting reference
or Unsupervised Relay Options:2098-9808 remote LED alarm
indicator or 4098-9822 relay
TrueAlarm Sensors (ordered separately)
Model Description Mounting Requirements
4098-9714 Photoelectric Smoke Sensor
Refer to page 2,mounting reference
4098-9733 Heat Sensor
Sounder Base Accessories (ordered separately if required)
Model Description Mounting Requirements
4098-9832 Adapter Plate,required for surface mounted 4"electrical boxes Refer to page 2,mounting reference
2098-9808 Remote red LED Alarm Indicator on single gang Single gang box, 1-1/2"minimum depth
Choose one if stainless steel plate
required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2"
4�9$-9822 mounted only in base electrical box) extension on 4"square or octagonal box)
'Refer to data sheet S4098-0019 for other compatible bases. Refer to Installation Instructions 574-707 and Application Manual 574-709 for
additional information.
• - . .
General Operating Specifications
Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400µA typical,
1 address per base,supplied by control panel
Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2)
Current 1 mA typical supplied from communications, no impact to alarm current
Remote LED Alarm Indicator
LED Connections Color coded wire leads, 18 AWG(0.82 mm2)
UL Listed Temperature Range 32°F to 100° F(0°C to 38°C)
Operating With 4098-9733 32°F to 122°F(0°C to 50°C)
Temperature Range With 4098-9714 15°F to 122°F(-9°C to 50°C)
Humidity Range 10 to 95%RH
Smoke Sensor 4098-9714, Air velocity is 0-4000 ft/min(0-1220 m/min)
Ambient Ratings Photoelectric Sensor
Housing Color Frost White
Sounder Operation
Sounder Voltage 18 to 32 VDC from steady external source or from NAC
Alarm Current(Sounder On) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC
88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling
Sounder Output Appliances and UL Standard 268,Smoke Detectors for Fire Protective
Signaling Systems
Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel
(Selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision
NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized
pattern(Temporal or March Time,etc.)controlled by the NAC
4098-9822 Unsupervised Relay Option
Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(wires to remote LED leads)
Alarm Current 13 mA from separate 24 VDC supply
Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC
resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC
Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base
TYCO,SIMPLEX,and the product names listed i�a this mater�ia[are mcmks arad/or regi,rtered marks.(Jrtauthorize�l use is strictly prohibited.NFPA 72 arad National Fire Alar�m and
Signaling Code m�e trademarlcr of ihe Nadaoraa!Fir•e Protection Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0028-7 4/2013
www.simplexgrinnell.com
OO 20/3 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx TrueAlarm Multi-Point Analog Sensing
UL, ULC, CSFMListed; FMApproved; TrueAlarm Multi-Sensor Model 4098-9754
MEA (NYC) Acceptance* Providing TrueSense Early Fire Detection
�
TrueAlarm photoelectric smoke sensing and heat
sensing combined in one housing to provide:
• Smoke activity accurately monitored by TrueAlarm ��
photoelectric sensing technology
• Thermal activity accurately monitared by TrueAlarm
thermistor sensing technology
• And TrueSense detection,a correlation of smoke �ti
activiry and thermal activity providing intelligent fire
detection earlier than with either activity alone
For use with Simplex°4100ES, 4010ES, and
4100U fire alarm control panels: TrueAlarm Multi-Sensor 4098-9754
Mounted in Standard Sensor Base
• TrueAlarm analog sensor information is digitally
coinmunicated to the control panel via lDNet _ � � � _ � �
two-wire communications
• Special point types allow the 4098-9754 multi-sensor TrueAlarm multi-sensor mode14098-9754 combines the
to communicate smoke and heat analog sensing data established performances of a TrueAlarm photoelectric
using only one IDNet address smoke sensor with a fast-acting and accurate TrueAlarm
Individual sensor information is processed by the host thermal sensor to provide both features in a single
• control panel to determine sensor status and to sensor/base assembly.
determine whether conditions are normal,off-normal, Digital Communication of Analog Sensing.
or alarm Analog information from each sensor is digitally
• (4100U fire alarm control panels require software communicated to the control panel where it is analyzed.
revision 11 or higher with multi-point compatible IDNet photoelectric sensor input is stored and tracked as an
transmission modules) average value with an alarm or abnormal condition being
determined by comparing the sensor's present value
Alarms can be determined by either: against its average value. Thermal data is processed to
• Smoke detection with selectable sensitivity from 0.2 look for absolute or rate-of-rise temperature as desired.
to 3.7%/ft obscuration(refer to additional informarion
on page 2) Intelligent Data Evaluation.Monitoring each
photoelectric sensor's average value provides a software
• Heat detection selectable as fixed temperature or fixed filtering process that compensates for environmental
with selectable rate-of-rise factors(dust,dirt,etc.)and component aging,providing
• TrueSense intelligent analysis of the combination of an accurate reference for evaluating new activity. The
smoke and heat activity result is a significant reduction in the probability of false
Additional design features: or nuisance alarms caused by shifts in sensitivity,either
Functional and architecturally styled enclosures for up or down. Status indications of dirty and excessively
• ceiling ar wall mounting dirty are automatically generated allowing maintenance to
be performed per device.
• Smoke sensor louver design that directs air flow to
chamber enhancing smoke capture Control Panel Selection.Peak activity per sensor is
• Built-in magnetic test feature stored to assist in evaluating specific locations. The alarm
set point for each TrueAlarm sensor is determined at the
• Compatible with standard bases(including relay control panel,selectable as more or less sensitive as the
control),sounder bases,and isolator bases individual application requires.
• Designed for EMI compatibility Multi-Point Reporting and CO Base Reference.
UL listed to Standard 268 Reporting 4098-9754"sub-points"under its single
address varies witb the base used.Muti-point details are
*This p'oduct has bcen approved by the Califomia State Fre N}arshal(CSFfV�pursuarrt to
Sedion 13144.1 of the Califomia H�Ith and SaFety Code.See CSFM Listirx,7s listed in data sheet 54090-0011.
7272-0026:218and7300-00'16:217fa-alloxablev�uesarxVorcoriditionsoor�ning Usin the 4098-9754 with CO sensor bases is detailed in
rrgterial presented in this doaamerrt.It is subjed to re-exanination,revision,arxJ possible g
car,oel�atia,.Pooeptedrause—atyorNewvaicoepartrrernoraui�air�—n�Fa�s3E. data sheet 54098-0041.
Refer to page 4 fa ULC listing status.Pdditional listings rrey be ap�licable;cbntact your
local Sirrplex procluct supplier fa-the latest status.Listirx,�s�d approvals under Sirrplex
Tirre FZeoorder Co.are the prq�erty of Tyoo Fre Protedion Products.
S4098-0024-8 11/2012
■ - � • • '• • � -
Timed/Multi-Stage Selection.Alarm set points can be TrueAlarm heat sensors monitor a fast reacting
programmed for timed automatic sensitiviry selection thermistar providing operation that is self-restoring and
(such as more sensitive at night, less sensitive during rate compensated.Due to its small thermal mass,the
day). Control pane]programming can also provide sensor accurately and quickly measures the]ocal
multi-stage operation per sensor. For example,a 02% teinperature for analysis at the fire alarm control panel.
level may cause a warning to prompt investigation while a The control panel allows alarm selection to be per sensor
2.5°/o level may initiate an alarm. as fixed temperature,or rate-of-rise temperature,ar the
Sensor Alarm and Trouble LED Indication.Each combination of both.
sensor base's LED pulses to indicate communicarions Temperature Detection.Rate-of-rise temperature
with the panel.If the control panel determines that a detection is selectable at the control panel for either 15°F
sensor is in alarm,or that it is dirty or has some other type (8.3°C)or 20°F(ll.1° C)per minute.Fixed temperature
of trouble,the details are annunciated at the control panel sensing is independent of rate-of-rise sensing and
and that sensor base's LED will be turned on steadily. selectable to operate at 135°F(57.2°C)or 155°F
During a system alarm,the control panel will control the (68°C).In a slow developing fire,the temperature may
LEDs such that an LED indicating a trouble will return to not increase rapidly enough to operate the rate-of-rise
pulsing to help identify the alarmed sensors. feature.However,an alarm will be initiated when the
- � � . . .
temperature reaches its selected fixed temperature setting.
Utility Temperature Monitoring. TrueAlarm heat
General mechanical: sensors can be programmed as a utility device to monitor
• Housing is sealed against rear air flow entry for temperature extremes in the range from 32°F to
• Electronics are EMI/RFI shielded 122°F(0°C to 50°C). This feature can provide freeze
Smoke sensing: warnings or alert to HVAC system problems.
• Photoelectric light scattering sensing technology ' � ' ' • � '
• 360°smoke entry for optimum response Control Panel Sensor Analysis. Each multi-sensor's
• Chamber screen provides protection from dirt,dust, and smoke and heat sensing element provides data for
insects evaluation at the fire alarm control panel where four
Heat sensing: independent detecrion modes are evaluated. They are:
• Fast response thermistar design
• Fixed temperature heat detection
• Rate compensated, self-resetting operation
• Rate-of-rise heat detection
• Control panel can select per sensor for fixed temperature
• TrueAlarm photoelectric smoke detection
sensing,rate-of-rise temperature sensing,or the • And TrueSense correlation detection
combination of both Comparing Photoelectric Activity and Thermal
- � . . _ � � _ Activity.TrueSense analysis correlates both thermal
activity and smoke activity at a single multi-sensor
TrueAlarm photoeleCtric sensors Lise a stable, location using an extensively tested covariance
pulsed infrared LED light source and a silicon photodiode relationship.As a result,TrueSense detection improves
receiver to provide consistent and accurate low power response to conditions indicative of faster acting,hot
smoke sensing. Seven levels of sensitiviry are available flaming fires when compared to the response of either
far each individual sensor,ranging from 0.2%to 3.7%per photoelectric smoke activity or thermal activity alone.
foot of smoke obscuration. Sensitivities of 0.2%,0.5%,
and 1%are for special applicarions in clean areas. High Integrity Detection. TrueSense operation
Standard sensitivities are 1.5%,2.0%,2.5%, and 3.7°/o. provides early fire detection and maintains the established
Sensitivity is selected and monitored at the fire alarm �igh level of immunity to false alarms and nuisance
control panel. * alarms that is inherent with TrueAlarm sensor operation.
Sensor head design provides 360° smoke entry for � ' ' • '
optimum smoke response.Because of the photoelectric Sensor locations should be determined after careful
sensing technology,the 4098-9754 sensor is UL listed for consideration of the physical layout and contents of the
air velocity of up to 4000 ft/min.However,care must be area to be protected. Refer to NFPA 72,the National Fire
taken in determining sensor locations to avoid areas Alarm and Signaling Code. On smooth ceilings, smoke
where local airflow may also impact any smoke flow. sensar spacing of 30 ft(9.1 m)may be used as a guide.*
(Refer to the application reference section on this page.)
" For detailed application information, refer to 4098
Detectors, Sensors, and Bases Application Manual,
document number 574-709.
2 S4098-0024-8 11/2012
. � . . • •
Base mounted address selection allows the address • Peak value logging allows accurate analysis for
of the multi-sensor base to remain witb its programmed sensitivity selection
location when the sensor is removed for service. . Automatic, once per minute individual sensor calibration
Integral red LED indicates power-on by pulsing,or check verifies sensor integrity
alarm or trouble when steady on,reflecting status of either • Multi-stage alarm operation
sensor. The exact status of the specific sensing element is . Selectable alarm verification
annunciated at the fire alarm control panel. . ALrtomatic environmental compensation and
- � . . • determinarion of dirry and excessively dirty
• Individual smoke sensitivity and temperature operation
• TrueSense analysis of smoke and heat activity
is selectable for each sensor • Ability to display and print detailed sensor information
• Sensitivity monitoring that satisfies NFPA 72 sensitivity in plain English language
testing requirements • Smoke sensitivity displayed in percent per foot and
temperature readings selectable as Fahrenheit or Celsius
. •
Electrical boxes are supplied by others,refer to notes below for additional information
Surface mount reference
4"(102 mm) _ ��4"(102 mm)
square box ��� � � �� � �� octagonal box
---- � � ---f--- � � ---
1-1/2"(38 mm) Flush mount reference,mount even with final
minimum box depth surface,or with up to 1/4"(6.4 mm)maximum recess
----------------------------------------------
�2098-9737 Relay(mounts 4098-9822 Relay� � Standard ize Base Mountina ;
� in base electrical box or (mounts in base � ; �
� remotely) electrical box) � ; 4098-9832 Adapter Plate,reauired for mounting �
� ; � 1/to surface mounted boxes and 4"sauare flush box �
� ' i I �
i � i i
i � i i
i � i i
� ' � �- 4098 Series Base �
� �
� � , �
� � , �
� � , �
� Relay Size: 2-1/2"X 1-1/2"X 1"(3.75 ' � 0 �
� cubicinches)(64mmX38mmX25.4mm) ' ;` __ ______ ___ ;
----------------------------------------------------------------------------------�
� 4098-9794 Sounder Base Mountina ;
� - �
; � For 4098-9794 only,when using 4"square box flush mount,a single ;
; gang adapter plate(RACO No.787 or equal,by others)is required ;
; 4098-9832 Adapter Plate,repuired for mounting ;
; �to surface mounted boxes(mounts inverted) �
� �
� �
� �
� �
� � 4098-9794 �
� SounderBase �
� �
�
� �
� I ,
� �
� �
� 4098-9754 Multi-Sensor �
� �
� �
i �.�r/ i
NOTES:
1. Review wire size,wire count,box type,and whether a locally mounted relay is used before determining box size.
2. When a locally mounted relay is used,mount relay in electrical box and use 1-1/2"extension ring(by others)on
4"square or octagonal box of 1-1/2"or 2-1/8"depth as required.
3. Flush mounting also fits a single gang box,2-1/8"(51 mm)deep if compatible with wiring requirements.(Not
applicable if a locally mounted relay is used.)
4.Refer to Systems Manual 574-709 for additional information.
3 S4098-0024-8 11/2012
. . .
TrueAlarm Multi-Sensor(ordered separately, refer to page 3 for mounting requirements)
Model Description
4098-9754 Multi-sensor, photoelectric sensor with integral thermal sensor;select base from list below
TrueAlarm Multi-Sensor Bases (ordered separately, refer to page 3 for mounting requirements)
Model Description For More Detail
See Data Sheet
4098-9792 Standard Sensor Base, no options
4098-9789 Sensor Base with connections for remote LED alarm indicator or unsupervised relay S4098-0019
4098-9791 Sensor Base with connections for Supervised Remote Relay and for remote LED alarm indicator
or unsupervised relay
4098-9793 Isolator Base with built-in IDNet communications isolator, no options S4098-0025
4098-9794 Sounder Base with connections for remote LED alarm indicator or unsupervised relay S4098-0028
Accessories Reference (ordered separately as required, refer to page 3 for additional mounting requirements)
Model Description
4098-9832 Adapter Plate,6-3/8"(162 mm)diameter, 1/4"(6.4 mm)deep, matches bases,see page 3 for required applications
2098-9808 Red LED Alarm Indicator on single gang stainless steel plate, mounts on single gang box, 1-1/2"
Choose one (38 mm)minimum depth
4098-9822 if applicable Relay with operation that tracks base LED status, mounts in base electrical box,4"square or
octagonal box with 1-1/2"(38 mm)extension ring, select box depth per actual wiring requirements
Compatible with Supervised Relay, mounts remotely or in base electrical box; remote mounting requires 4"
2098-9737 4098-9791 only octagonal or 4"square box, 1-1/2"minimum depth; base mounting requires 4"octagonal box,
2-1/8"deep with 1-1/2"extension ring
. -
General Operating Specifications(refer to data sheet list for additional detail)
Communications and Sensor Supervisory Power 4100ES,4100U,4010ES IDNet communications,24-40 VDC with data,400µA
typical;supplied by control panel
UL Listed Temperature Range 32° F to 100° F(0°C to 38°C)
Operating Temperature Range 15° F to 122° F(-9°C to 50°C)
Humidity Range 10 to 95% RH
Smoke Sensor Sensitivity Range 0.2%to 3.7% per foot of smoke obscuration, selected at control panel(refer to
additional information on page 2)
Smoke Sensor Air Velocity Range 0-4000 ft/min (0-1220 m/min)
Thermal Sensor Operation Fixed alarm temperature setting of 135° F(57.2° C), and/or rate-of-rise
(selected at control panel) temperature alarm at 15° F(8.3° C)or 20° F(11.1°C),also selectable as utility
monitoring operation from 32° F to 122° F(0°C to 50°C)
Housing Color Frost White
� 1 ' : • • • � •
- 6-7/16"(164 mm) -
I� 4-7/8"(124 mm)-�I ---
� 0
2-1/4"
(57 mm) 2-7/16" �
0� (62 mm) J
LED status LED status
indicator indicator
� Sound output
louvers extend
Thermistor guard� Thermistor guard� from front and side
Standard Size Base Mounting Sounder Base Mounting
TYCQ SLMPLEX,and the product names listed in this materral a��e mnrks and/or registered marks.Unaud{xorized use is strictly prohihited.NFPA 72 and National Fire Alarm
and Signaling Code are b�ademarks of the Natioraal Fire Protection Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0024-8 11/2012
www.simplexgrinnell.com
OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx TrueAlarm Analog Sensing
UL, ULC, CSFM Listed; FM Approved; Dual Address Bases for Multi-Sensor
MEA (NYC) Acceptance* 4098-9754, Standard and Sounder
�
TrueAlarm photoelectric sensing and TrueAlarm
thermal sensing combined in one housing:
• TrueAlarm photoelectric technology accurately —,
monitors for smoke activiry
• TrueAlarm thermal sensing accurately monitars for ,
fixed temperature and rate-of-rise temperature, selected �_
or combined as required per sensor ~~�
• Basic operation is UL listed to Standard 268 TrueAlarm Multi-Sensor 4098-9754 Mounted in
• Sounder operation is also listed to UL Standard 464 as Multi-Sensor Sounder Base 4098-9795
an audible notification appliance
Multi-Sensor Standard Base 4098-9796 provides:
• Two sequentially addressed points,automatically .�
assigned with one address selection
• Connections for remote LED or LED tracking relay for �
remote alarm status indication
Multi-Sensor Sounder Base 4098-9795 provides - r
the features of 4098-9796 and also provides: r,
• Built-in piezoelectric sounder with high output
(88 dBA)and low current requirements(20 mA) TrueAlarm Multi-Sensor 4098-9754 Mounted in
• Sounder power can be from 24 VDC or from a Multi-Sensor Base 4098-9796
compatible Notification Appliance Circuit(NAC)
- � . � - . .
• Sounder output can be synchronized via
communications or by the NAC,if NAC powered** TrueAlarm multi-sensor 4098-9754 combines the
• Sounder operation can be independently activated from established performances of a TrueAlarm photoelectric
the host control panel smoke sensor with a fast-acting and accurate TrueAlarm
TrueAlarm analog sensing operation. thermal sensor to provide both features in a single
• Analog sensor information is digitally communicated to sensor/base assembly.
the control panel via lDNet or MAPNET II two-wire Digital Communication of Analog Sensing.
communications Analog information from each sensor is digitally
• Individual sensor information is processed by the host communicated to the control panel where it is analyzed.
control panel to determine sensor status Photoelectric sensor input is stored and tracked as an
For use with the following Simplex°products: average value with an alarm or abnormal condition being
• Model Series 4008,4010,4100ES,4010ES,and 4100U determined by comparing the sensor's present value
fire alarm control panels against its average value. Thermal data is processed to
• Note:4008 Series fire alarm control panels provide a look for absolute or rate-of-rise temperature as desired.
reduced feature set,refer to data sheet 54008-0001 Intelligent Data Evaluation.Monitoring each
• Legacy models 4020/4100/4120 Series fire alarm photoelectric sensar's average value provides a software
control panels,and Universal Transponders equipped filtering process that compensates for environmental
for MAPNET II operation factors(dust,dirt,etc.)and component aging,providing
• For use with 4100ES,4100U,or 401 OES control panels, an accurate reference for evaluating new activity. The
multi-sensor 4098-9754 is also available using single result is a si�nificant reduction in the probability of false
address bases;refer to data sheet 54098-0024 for more or nuisance alanns caused by shifts in sensitivity,either
information,including TrueSense early fire detection up or down.
operation combining photo and heat inputs
' l7tis product has bcen ap�xoved by the Califorrtia State Fre N�rsF�al(CSFN�pursuarrt to
Functional and architecturally styled enclosures Sedion13144.1oftheCalifaniaH�IthandSafetyCode.SeeCSFMListing
are for ceilin OI'WaII PT10UIltl11 : ��4��217faallw�ablevaluesar�d/aoonditia�scorioerningrrateri�presentedinthis
9 J doaarr�it.It is subject to ree�rination,revision,and possible car�cellation.F�ted for
• Smoke sensor louver design directs air flow to chamber, use—�1tYofNewYaicDepartrrentofBuildings—NEP3S93EPr1ditionallistingsrraybe
enhancing smoke capture appicar�e;contactyourlocalSirrpleacproductsupplierfathelateststatus.Listingsand
ap�xovals urxler Slrrplex Tirre Recorder Co.are the property of Tyoo Fre Protedion
• Sound louvers on sounder base exit both front and side aoduas.
for high output sound *"Total quarrtity of saxxler l�ases available fa ooding on the sarr�corrrrunicatia�s d�anrid
• Built-in magnetic test feature alarms both addresses �"�'�thpane�applicationarxlavailabilityofNACpa,ner.Refertospeaficoortrd
par�requirerr�errts.
• Designed for EMI compatibility
• Optional accessories include remote alarm LED
indicator or alarm LED tracking relay
S4098-0033-5 9/2012
■ - � • • '• •
Control Panel Selection.Peak activity per sensor is TrueAlarm heat sensors monitor a fast reacting thermistor
stored to assist in evaluating specific locations. The alarm providing operation that is self-restoring and rate
set point for each TrueAlarm sensor is determined at the compensated. Due to its small thermal mass,the sensor
control panel,selectable as more or less sensitive as the accurately and quickly measures the local temperature far
individual application requires. analysis at the fire alarm control panel. The control panel
Timed/Multi-Stage Selection.Alarm set points can be allows alarm selecrion to be per sensor as fixed
programmed for timed automatic sensitivity selection temperature,or rate-of-rise temperature,or the
(such as more sensitive at night,less sensitive during combination of both.
day). Control panel programming can also provide Rate-of-rise temperature detection is selectable at the
mulri-stage operation per sensor.For example,a 0.2% control panel for either 15°F(8.3°C)or 20°F(11.1° C)
level may cause a warning to prompt investigation while a per minute. Fixed temperature sensing is independent of
2.5%level may initiate an alarm. rate-of-rise sensing and selectable to operate at 135°F
Sensor Alarm and Trouble LED Indication.Each (57.2°C)or ]55°F(68°C).In a slow developing fire,the
sensor base's LED pulses to indicate communications teinperature may not increase rapidly enough to operate
with the panel.If the con�rol panel determines that a the rate-of-rise feature. However,an alarm will be
sensor is in alarm, or that it is dirty ar has some other rype initiated when the temperature reaches its selected fixed
of trouble,the details are annunciated at the control panel temperature setting.
and that sensor base's LED will be turned on steadily. TrueAlann heat sensors can be programmed as a utility
During a system alarm,the control panel will control the device to monitor for temperature extremes in the range
LEDs such that an LED indicating a trouble will return to from 32°F to 122°F(0° C to 50°C).This feature can
pulsing to help identify the alarmed sensors. provide freeze warnings or alert to HVAC system
. , , , � � � problems. (Refer to specific panels for availabiliry.)
� . • .
Sealed against rear air flow entry
Electronics are EMI/RFI shielded Sensor locations should be determined after careful
consideration of the physical layout and contents of the
Smoke sensing: area to be protected.Refer to NFPA 72,the National Fire
• Photoelectric sensing technology Alarm and Signaling Code. On smooth ceilings, smoke
• 360°smoke entry for optimum response sensor spacing of 30 ft(9.1 �n)may be used as a guide.
• Chamber screen provides protecrion froin dirt,dust, For detailed application information,refer to 4098
and insects Detectors, Sensors, and Bases Application Manual, Part
Number 574-709.
Heat sensing:
• Fast response thermistor design - • � .
• Rate compensated, self-resetting operarion
• Control panel can select per sensor for fixed I�� sa/�s°(�sa mm) -
temperature sensing,rate-of-rise temperature sensing,
or the combination of both
. . - .
- - 2-7/16" �
TrueAlarm photoelectric sensors use a stable,pulsed (sz mm)
infrared LED light source and a silicon photodiode �E�status �
indicator
receiver to provide consistent and accurate low power . --- ,
smoke sensing. Seven levels of sensitivity are available Sound output louvers extend
for each individual sensor,ranging from 0.2%to 3.7%per from front and side
foot of smoke obscuration. Sensitivity is selected and
monitored at the fire alarm control panel. Multi-Sensor with 4098-9795 Multi-Sensor Sounder Base
The sensor head design provides 360° smoke entry for i
. 4-7/8"(124 mm)�i
optimum smoke response.Because of the photoelectric �
sensing technology,the 4098-9754 sensor is UL listed for
air velociry of up to 4000 ft/min.However,care must be � o
2-1/4"
taken in determining sensor locations to avoid areas �s��„m�
where local airflow may also impact any smoke flow. %
LED status
(Refer to the application reference section on this page.) indicator
Multi-Sensor with 4098-9796 Multi-Sensor Base
2 S4098-0033-5 9/2012
. � . . • •
Base mounted address selection allows the • Sensitivity monitoring that satisfies NFPA 72
addresses of the multi-sensor base to remain with its sensitiviry testing requirements
programmed location when the sensor is removed for . Peak value logging allows accurate analysis for
service. sensitivity selection
Integral red LED indicates power-on by pulsing,or • Automatic,once per minute individual sensor
alarm or trouble when steady on,reflecting status of either calibration check verifies sensor integrity
sensor. The exact status of the specific sensing element is • Multi-stage alarm operation
annunciated at the fire alarm control panel. • Selectable alarm verification
. � • Ability to correlate sensitivity selection with
. .
temperature
• Individual smoke sensitivity and temperature • Automatic environmental compensation
operation is selectable for each sensor • Smoke sensitivity displayed in percent per foot
• Ability to display and print detailed sensar
information in plain English language
. .
Electrical boxes are supplied by others,refer to notes below for additional information
Surface mount reference
4"(102 mm) ��4"(102 mm)
square box � � � � octagonal box
\ + /
1-1/2"(38 mm) Flush mount reference,mount even with final
minimum box depth surface,or with up to 1/4"(6.4 mm)maximum recess
; ; � 4098-9796 Multi-Sensor Base Mountina �
, Outional 4098-9822 Relav , ,
� (Mounts in base electrical box and requires ; � 4098-9832 Adapter Plate,required for mounting �
� additional volume,see notes 1 and 2 below) ; � /to surface mounted boxes and 4"spuare flush box �
� ' � i �
� � , �
� � , �
; Relay size: ' � 4098-9796 Multi-Sensor Base '
; 2-1/2"X 1-1/2"X 1" � � ;
; (64 mm X 38 mm X 25.4 mm) ; � ;
� (3.75 cubic inches) ; � � �
� � ; �
' �---------------------------------------------'
---------------------------------------------------------------------------------�
� 4098-9795 Multi-Sensor Sounder Base Mountina �
� - �
; p For 4098-9795 only,when using 4"square box flush mount,a single ;
; gang adapter plate(RACO No.787 or equal,by others)is required ;
; /4098-9832 Adapter Plate,required for mounting ;
; �/ to surface mounted boxes(mounts inverted) �
� ► ,
� �
� �
� �
� �
� �
; 4098-9795 �
� O Multi-Sensor �
� SounderBase �
i i
i i
i i
i i
� 4098-9754 Multi-Sensor �
�
� �
� „ �
� � �
� ------------------�
NOTES:
1. Review wire size,wire count, box type,and whether 4098-9822 relay is used before determining box size.
2. When 4098-9822 relay is used, mount relay in electrical box and use 1-1/2"extension ring(by others)on
4"square or octagonal box of 1-1/2"or 2-1/8"depth as required.
3. Flush mounting also fits a single gang box,2-1/8"(51 mm)deep if compatible with wiring requirements.
(Not applicable if 4098-9822 relay is used.)
4. Refer to Installation Instructions 574-707 for additional information.
3 S4098-0033-5 9/2012
. . .
TrueAlarm Multi-SensoP(ordered separately, refer to page 3 for mounting requirements)
Model Description
4098-9754 Multi-sensor, photoelectric sensor with integral thermal sensor,for use with bases 4098-9795 and 4098-9796
TrueAlarm Multi-Sensor Bases (ordered separately, refer to page 3 for mounting requirements)
Model Description
4098-9795 Sounder Base Dual address base for multi-sensor 4098-9754;with connections for remote LED alarm
4098-9796 Standard Base �ndicator or unsupervised relay
Accessories (ordered separately as required, refer to page 3 for additional mounting requirements)
Model Description
4098-9832 Adapter Plate,6-3/8"(162 mm)diameter, 1/4"(6.4 mm)deep, matches bases, required for some mounting
combinations
2098-9808 Red LED Alarm Indicator on single gang stainless steel plate, mounts on single gang box,
Choose 1-1/2"minimum depth
one if
4098-9822 required Relay with operation that tracks base LED status, mounts in base electrical box,4"square or
octagonal box with 1-1/2"(38 mm)extension ring,select box depth per actual wiring requirements
. - . •
General Operating Specifications
Communications and Sensor Supervisory Power IDNet or MAPNET II communications,auto-select,24-40 VDC w/data,400µA typical,
supplied by control panel,2 addresses per base
Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG
Current 1 mA typical supplied from communications, no impact to alarm current
Remote LED Alarm Indicator
LED Connections Color coded wire leads, 18 AWG
UL Listed Temperature Range 32°F to 100°F(0°C to 38°C)
Operating Temperature Range 15°F to 122°F(-9°C to 50°C)
Humidity Range 10 to 95%RH
Smoke Sensor Sensitivity Range 0.2%to 3.7%per foot of smoke obscuration,selectable at host control panel
Smoke Sensor Air Velocity Range 0-4000 ft/min(0-1220 m/min)
Thermal Sensor Operation Fixed alarm temperature setting of 135°F(57.2°C),and/or rate-of-rise temperature
(selected at host control panel) alarm at 15°F(8.3°C)or 20°F(11.1°C),also selectable as utility monitoring
operation from 32°F to 122°F(0°C to 50°C),availability is panel dependent
Sensor,Bases,and Adapter Plate Color Frost White
Sounder Operation with 4098-9795 Multi-Sensor Sounder Base
Sounder Voltage 18 to 32 VDC from steady external source or from NAC
Alarm Current(sounder on) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC
Sounder Output 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Appliances
and UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems
Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel
(selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision
NAC Powered Operation When sounder is activated by control panel,sounder output tracks connected NAC to
allow synchronized coding(Temporal or March Time,etc.)
4098-9822 Unsupervised Relay Option
Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(connects to remote LED leads)
Alarm Current 13 mA from separate 24 VDC supply
Contact Ratings, DPDT contacts for Power limited rating:2 A@ 30 VDC
resistive/suppressed loads Non-power limited rating: 1/2 A@ 120 VAC
Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base
TYCQ SIMPLEX,and the product names listed in this rnateria!are marlcs and/m�registered mark.r.Unauthorized use is strictly proh�ibited.NFPA 72 is a eegistered trademarlc of
the Nafional Fire Pr�otectron Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0033-5 9/2012
www.simplexgrinnell.com
OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx TrueAlarm Analog Sensing
UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm
MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control
� x I�I • �, x o
,,,
Compact air duct sensor housing with clear , _
cover to monitor for the presence of smoke** �, ��e,,,
0000000
Includes factory installed TrueAlarm �o o�0000� '�a
photoelectric smoke sensor and features: o o��000 o,"
,�� o � n[ia.
• Individual sensor information processed by the host __ o o �„�,
control panel to determine sensor status � � � °�;
x „ -.—,
• Digital transmission of analog sensor values via IDNet
or MAPNET II,2-wire communications � �1
�• Programmable sensitivity,consistent accuracy, \
environmental compensation, status testing,and o��
monitoring of sensor dirt accumulation
Model 4098-9755:
• Basic duct sensor housing(no relay output)powered
by IDNet/MAPNET II communications Duct Sensor Housing, Front and Bottom View
Model 4098-9756:
• Duct sensor housing with supervised output for � �
multiple remote relays;requires separate 24 VDC; ��M ���
includes one relay oa,��
s�mw�
• Relay output is under panel control °�ma°�
m �
• At the panel,relay output can be activated manually or �
in response to a separate alarm or other input 2098-9808 2098-9806
General features: Remote Status/Alarm Indicator and Test Station
• UL listed to Standard 268A . . .
• Clear cover allows visual inspection �
OperatiOn.Simplex compact air duct smoke sensar
• Test ports provide functional smolce testing access housings provide TrueAlarm operation for the detection of
with cover in place smoke in air conditioning or ventilating ducts. Sampling
• Mounts to rectangular ducts or round ducts;minimum tubes are installed into the duct allowing air to be directed to
size is 8"(203 mm)square or 18"(457 mm)diameter the smoke sensor mounted in the housing.
• Magnetic test feature for alarm initiation at housing - . . � . - , .
• Optional weatherproof enclosure is available Digital Communication of Analog Sensing.
separately(refer to data sheet 54098-0032) Analog infonnation from tbe sensor is digitally
DiagnoStiC LEDS (on interfaCe board): communicated to the control panel where it is analyzed.
• Red Alarin/Trouble LED for sensor status and Sensor input is stored and tracked as an average value
communications polling display with an alarm or abnormal condition being determined by
• Yellow LED for open or shorted trouble indication of comparing the sensor's present value against its average.
supervised relay control(4098-9756 only) Intelligent Data Evaluation.Monitoring each
Sampling tubes (ordered separately): photoelectric sensor's average value provides a software
filtering process that compensates for environmental
• Available in multiple lengths to match duct size factors(dust,dirt,etc.)and component aging,providing
• Installed and serviced with housing in place an accurate reference for evaluating new activity. The
Remote module options (ordered separately): result is a significant reduction in the probability of false
• Remote red status/alarm LED(2098-9808) ar nuisance alarms caused by shifts in sensitivity,either
up or down.
• Remote test station with LED(2098-9806)
• 4098-9843 remote relays(refer to page 2 for details) � ���e that smoke detedion in air ducts is ir�erxled to provide
notification of the presence of srrnke in the duct.It is not i�tended
` These products have been approved by the C�ifartia State Fre N�rslx�l(�purs�.kant to to,and will not,replace srra{ce detedion requirements for open
Sedion 13144.1 of the Califania H�th and SaFety Code.See CSFM Listing 3240-002G.241
fa allava�le v�ues arxUor conditions oor�ceming material presented in this docurrerrt.It is ������dU(�2�IC�101'1S.
subjed to re-e�nination,revision,arxi possible car�lation.Accepted for use—Qry of New
Yaic Department of Buildings—NEP3.rr93E.Prlditional listings rray be applic�le;mrrtact
your loc�55rrplex product supplier for the latest status.Listirx�s and approvals urxier Sirrplex
Tirm Recorder Co.are the�xoperty of Tyco Fre Protedion Produds.
S4098-0030-9 11/2012
- � • • � - • � �• • • - • • '•
Control Panel Selection.Peak activity per sensor is Typically duct sensor applications require less sensitive
stored to assist in evaluating specific locations. The alarm settings(such as 2.5%per foot obscuration)due to the
set point for each sensor is determined at the control ducts being a relative dirry environment. However,the
panel, selectable as tbe individual application requires. standard seven levels of TrueAlarm sensor sensitivity are
Sensor Status LED.Each sensor housing's red status av oilable for each individual sensor,ranging from 02%to
LED(located on the electrical interface board)pulses to 3.7/o per foot of smoke obscuration. Sensitivity is
indicate communications with the panel.If the control selected and monitored at the fire alarm conYrol panel.
panel determines that a sensor is in alarm,or that it is - � . . -
dirty or has some other type of trouble,the details are
annunciated at the control panel and that sensor housing's • Individual smoke sensirivity seleckion
status LED will be turned on steadily.During a system • Sensitivity monitoring that satisfies NFPA 72
alarm,the control panel will control the LEDs such that sensitivity testing requirements
an LED indicating a trouble will return to pulsing to help . Peak value logging allows accurate analysis for
identify any alarmed sensors. (Remote Status/Alarm sensitivity selecrion
LEDs track the operation of the sensor housing LED.)
• Automatic, once per minute individual sensor
' • • - - • calibration check verifies sensor integrity
TrueAlarm photoelectric sensors use a stable,pulsed • Automatic environmental compensation
infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot
receiver to provide consistent and accurate low power . Ability to display and print detailed sensor
smoke sensing. information in plain English language
• Relays of mode14098-9756 are under panel control
� � � for ON, OFF,or override
Duct Smoke Sensor Housing with Photoelectric Sensor*
Model Description Compatibility
Basic Duct Sensor Housing;operating power is supplied by Simplex fire alarm control panel models:4100ES,
4098-9755 either IDNet or MAPNET II communications(no relay 4010ES,4008,4010,4100U,and legacy products
output) 4020,4100/4100+,and 4120.Also 2120 CDT if
configured for MAPNET II,TrueAlarm operation
Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not
4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT;
end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays
(additional relays are ordered separately)
Remote LED Indicator and Test Station, Select One if Required
Model Description Compatibility Mounting
2098-9808 Red LED status indicator on single-gang stainless steel plate
4098-9755 Use single gang box,
Test Station with keyswitch and red LED status indicator,on 3"H x 2"W x 2"D
2098-9806 single-gang stainless steel plate; (turning switch to"TEST" 4098-9756 �76 mm x 51 mm x 51 mm)
initiates alarm for system testing)
Epoxy Encapsulated Remote Relay and End-of-Line Resistor
Model Description Compatibility Location
Relay;single Form C(7 A@ 120 VAC); refer to pages 3 and 4 Locate relays within 3 ft
4098-9843 for additional relay information;one included with 4098-9756; 4098-9756 only; (1 m)of device being
wiring is 18 AWG(0.82 mm2)color coded wire leads connect up to 15 controlled per NFPA 72
4081-9008 End-of-Line Resistor Harness; 10 kS2, 1/2 W; (ref.733-894); 4098-9756 At last relay location
required to supervise remote relay coil connection
`Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube.A correctly
sized sampling tube(ordered per application)is required,refer to chart below.
• • • - • • • - - • - • . � • •
Overall Duct Width Tube Required Suggested Cut Length
12"(305 mm) 4098-9854 1/2"(12.7 mm)longer than duct width
13"to 23"(330 mm to 584 mm) 4098-9855 1/2"(12.7 mm)longer than duct width
24"to 46"(610 mm to 1168 mm) 4098-9856 3 in"(76 mm)longer than duct width
46"to 71"(1168 mm to 1803 mm) 4098-9857 3 in"(76 mm)longer than duct width
71"to 95"(1803 mm to 2413 mm) 4098-9858 3 in"(76 mm)longer than duct width
2 S4098-0030-9 11/2012
� • • � � -
NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information.
11-3/8"(289 mm)
Exhaust tube access hole � Conduit(by others)
� � x
4098-9714 Smoke sensor,mounted
in special interface base(supplied) i ��Metal plate with dual holes
6-3/4"
(171 mm) • �� for 3/4"(19 mm)conduit,plug
�•. ��, - ""' supplied for unused hole
°0000000 ��°
0
0 000o Q 1 �
0 0
0 0 OOCJ CIO Yellow LED,relay control trouble
indicator(4098-9756 only)
Sampling tube � � 0
access hole � o 0 0 Red sensor
� �� status LED Side of duct
u o0
x • x o "-- -' o
Wiring terminals
Stationary baffle(built-in) Captive fastening screws(4) Ma netic test area
NOTE:Orientation shown is for reference
Transparent cover Gasketed sensor area only,refer to General Location Notes and
End View illustration below for alternate
� mounting reference.
3-3/8" ;� n'���� �I
��
�'�� ������-�
(86 mm) ■ : . .
b��
Duct wall
z �
13/16"
(21 mm) Exhaust tube 4098-9843 Remote Relay
(supplied) (7 A@ 120 VAC,for use with 4098-9756 only)
Test ports(2)provided NOTE: Mount in separate electrical box within
Sampling tube,ordered Gaskets su lied 3 ft(1 m)of device being controlled per
for measuring airflow separatel � pp �
y per duct width NFPA 72
and for aerosol injection
1-3/16"
(30 mm)
1-1/2„ \ 13/16„
Square duct Alternate location (38 mm) �� �(21 mm)
reference outline (if appropriate) �
��
18"Round duct outline
(minimum diameter) Sampling tube,keyed for proper hole alignment with holes facing
into airflow(template is provided for proper tube installation).
(Housing is shown as position 2 per note 2 below.)
- -----------�
General Location Notes:
• • ' • • 1.Testing performed under the auspices of the Fire Detection
, Institute(FDI)recommended when sampling tubes are not
� located vertically,that they be positioned horizontally in the
Duct � � upper half of the duct to account for possible stratifcation.
housing �
� � �. 2.Three duct side mounting options are available as shown below.
� Mount housing at 90°to airflow for all orientations. / �
' Arrows indicate allowed airflow directions. T
�
- ----------=-
�, I
' � � ��, �z; � � �3 ���i°o�vi�i
Exhausttube P '�� � _
8"Square duct outline � — � ' � �' d
(minimum width) � _v� � ` _ �
� [ y'
. �J�., r� . I
------------ ------------ '8
DO NOT MOUNT ON
BOTTOM OF DUCT
/ \
3 S4098-0030-9 11/2012
� . . . . Duct Sensor Location Considerations:
1. Proper duct smoke detection location must ensure
�EXnaust�amper �ser,sor oK adequate airflow within the duct housing.
2. Duct air velocity rating is 300 to�4000 ft/min(91 to
Exnaust f � �—Return air 1220 m/min).Pressure differential between intake
and exhaust tubes is required to be between 0.015 to
�o not iocate ; 1.55 inches of water(0.381 to 39.37 mm).
sensor here
3. Ensure accessibility for test and service.
Return air
damper 4. Proper Locations: downstream side of filters to detect
fires in the filters; in return ducts,ahead of mixing
areas; upstream of air h�unidifier and cooling coil.
5. Other locations and orientations may be required for
Fresh air� '; � Supply Air proper duct smoke detection depending on duct
' access, system design,and duct airflow testing.
�Jnot iocate Filter ba k �sensor oK Contact your local Simplex product supplier for
sensor here 75S15tflriCe.
Locations to Avoid:
Additional Information.Refer to NFPA 90A,Standard 1. Where dampers closed for comfort control would
for the Installation of Air Conditioning and T�entilating interfere with airflow.
Systems;NFPA 72,the National Fire Alarm and Signaling 2, Next to outside air inlets(unless the intent is to
Code;and the NEMA Guide for Proper Use of Smoke monitor smoke entry from that area).
Detectors in DuctApplications,and Installation Instructions 3. In return air damper branch ducts and mixing areas
574-776. where airflow may be restricted.
• - , .
General Mechanical and Environmental
Air Velocity Range(linear fUmin) 300 to 4000 ft/min(91 to 1220 m/min)
Sensor Sensitivity Range 0.2%to 3.7%per foot of obscuration,selectable at host control panel
UL Listed Temperature Range 32° F to 100° F(0°C to 38°C)
Operating Temperature Range 32° F to 122° F(0°C to 50°C)
Storage Temperature Range 0° F to 140° F(-18° C to 60° C)
Humidity Range 10%to 95%RH, non-condensing
Wiring Connections Terminal blocks, 18 to 12 AWG(0.82 mm2 to 3.31 mmz)
Housing Color Black base with clear cover
Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED
Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current(2098-9808 or 2098-9806)
Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current(2098-9806)
Remote Alarm LED and Test Station Distance 250 ft(76 m)maximum
Addressable Operation
Data Communications IDNet or MAPNET II communications, auto-select,one address per housing;
provides operating power to model 4098-9755
Model 4098-9756 with Supervised Multiple Relay Control,Requires Separate Fused 24 VDC from Fire Alarm Power Supply
Input Voltage 18-32 VDC(24 VDC nominal)
Standby Current 3 mA @ 24 VDC
Alarm Current 15 mA @ 24 VDC;add 15 mA for each 4098-9843 relay
For use with 4098-9843 relay only,quantity of 15 maximum;distance of 500 ft
Supervised Remote Relay Control Output (152 m)maximum; requires 4081-9008(ref.733-894) 10 kS2, 1/2 W end-of-line
resistor
4098-9843 Relay Output Ratings,Single Form C, use with Model 4098-9756 Only
Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output
Relay Contacts 7 A at 0.35 PF @ 28 VDC&120 VAC;250µA @ 5 VDC
Location Distance 500 ft(152 m)maximum to relay coils; locate relays within 3 ft(1 m)of device
being controlled per NFPA 72
TYCO,SIMPLEX,anr/the product narnes listed in Chis material are markr and/or r�egistered marks.Unauthorized use ds strictly prohibited.NFPA 72 and Nationa/Fire Alar»z and
Signaling Code ar�e registered tradernar-ks oJ�the National Flr�e Protecfion Association(NFPA).
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4098-0030-9 11/2012
www.simplexgrinnell.com
OO 20/2 Tyco Fire Protection Products.All righzs resc�ved.A!!spec�ificarioras ancl other ir fonnutt'on shown were current as of'docurnent revision dute and are subject to change without rzotice.
�oSimplEx Multi-Application Peripherals
UL, ULC, CSFM Listed; FMApproved; IDNetT"" and MAPNET II° Communicating Devices,
MEA (NYC) Acceptance* Individual Addressable Modules (IAMs)
� �
IDNet or MAPNET II addressable communications �
supply both data and power over a single wire pair s��15!!?'�plex
to provide'`*: qo90 soo� ��
su��RUis�o ia� C�
• Supervised Class B monitoring of normally open,dry i�s�.iNSrR.5�4-331
DpTE CODE:
contacts M ? ,I„E,I�.
�.ome N- 3
• Total wiring distance from IAM to supervision
resistor(s)of up to 500$(152 m) � �00 p�
• Monitored connecrion is compatible with Simplex°
2081-9044 Overvoltage Protectors for outdoor wiring or
electrically noisy applications 4090-9001 Supervised IAM
• For use in indoor locarions up to 158°F(70° C)such as (shown approximately 3/4 size)
attic spaces or similar applications
For use with following Simplex control panels:
• Model Series 4008,4010,4010ES,4100U and 4100ES
fire alarm control panels for IDNet communications
• Model Series 4100/4100U/4100ES,4120,4020,and
2120 Communicating Device Transponders(CDTs)
equipped with MAPNET II communicarions
Model 4090-9001:
• Enclosed design minimizes dust infiltration
• Mounts in standard single gang electrical box �� "sTE°
SIGNq�INGOEVICE
ISSUE NO
• Screw terminals for wiring connections
• Visible LED flashes to indicate communications
• Optional covers are available to allow LED to be
viewed after installation(requires mounting bracket, 4090-9051 Supervised IAM
(shown approximately 3/4 size)
ordered separately)
Model 4090-9051:
• Encapsulated design for extended exposure to high � . � �
humidity(LED is not present on this model)
• Color coded 18 AWG leads for wiring Individual addressable modules (IAMs) receive
IDNet communications provides current limited both power and communications from a two-wire
monitoring: MAPNET II or IDNet circuit. They provide location
• Provides monitaring of tamper switch(supervisory) specific addressability to a single initiating device(such
and waterflow switch(alann)on same circuit using as single station smoke detector alarm contacts ar heat
detector contacts)or multiple devices at the same location
one point by monitoring normally open dry contacts and the wiring
• Available with IDNet communications only to an end-of-line resistar.
Multiple operation modes are available and are
selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic
• Contact closure status can be tracked housing and provides screw terminal connections and a
status indicating LED.
• Momentary contact closure conditions can be selected at
the panel to be latched ar tracked(not available with the Model 4090-9051 is an encapsulated package with wire
2120 CDT) leads. It does not provide a status indicating LED.
UL listed to Standard 864
` These products have been approvetl by the California State Fire Marshal(CSFM)pursuant
to Section 13144.1 of the California Health and Safety Code.See CSFM Listing
7300-0026:223 for allowable values and/or conditions concerning material presented in this
tlocument.It is subject to re-examination,revision,antl possible cancellation.Accepted for
use—City of New York Department of Buildings—MEA35-93E.Additional listings may be
applicable;contact your local Simplex product supplier for the latest status.Listings and
approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products
Westminster.
S4090-0001-10
• • - . • - � • • - • � • • •
Contact Closure. Closure ofthe monitored contact(s) For use with IDNet communications only,these
initiates an alarm or other response as programmed at the IAMs can provide quad-state sensing of normal,open
fire alarm control panel. An open in the monitored circuit circuit, short circuit,and current limited conditions.
wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line
Panel SeleCtions. Selections can be made at the control and current limiting resistors, dual functions such as
panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be
device contacts are momentary, such as from a determined and communicated by a single addressable
rate-of-rise heat detector,or to track the device contact point.
status(not available with the 2120 CDT).
� . • .
Model Description
4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals;see applicable options below
4090-9051 Supervised IAM,encapsulated with wire leads
Optional Trim Plates and Mounting Bracket for Model 4090-9001
Model Description
4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket,
4090-9807 For surface mounted box includes mounting screws;galvanized steel
4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim
plates
End-of-Line Resistor Harnesses (ordered separately as required)
Model Reference No. Description
4081-9004 733-886 6.8 kS2, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision
4081-9003 733-896 4.7 kS2, 1/2 W
Use for current limited monitoring applications
4081-9005 733-984 1.8 kS2, 1/2 W
. - . .
Electrical
Power and Communications MAPNET II or IDNet,auto selected, 1 address per IAM
Input Requirements Normally open,dry contacts
4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire
Wire Connections (0.82 mm to 2.08 mm )
4090-9051 Color coded wire leads, 18 AWG(0.82 mmZ),8"long(203 mm)
Installation Instructions 574-331 for 4090-9001; 579-572 for 4090-9151
Reference Documents
Field Wiring Diagrams 842-073 for IDNet operation; 841-804 for MAPNET II operation
Wiring Distances
500 ft(152 m)maximum without protectors
Distance from IAM to Contacts
400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors
Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel
IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps)
Mechanical
4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm)
Dimensions
4090-9051 1-9/16"W x 1-9/16" H x 9/16" D(40 mm x 40 mm x 14 mm)
Housing Material,4090-9001 Black thermoplastic
Encapsulation Material,4090-9051 Epoxy, beige
Temperature Range 32°to 158° F(0°to 70°C); intended for indoor operation
Humidity Range Up to 93% RH at 100° F(38°C)
2 S4090-0001-10
. . . .
� �
4090-9001 IDNet Field wiring shown
supervised IAM for reference
m
� S��EX iINE�.
4�90-9001
suv�uis�o iau
xsi.ixsiw.s�e s�i
opiE cooE. LED viewing port
M��o�Er ��.q
u o0 000
� Single gang electrical
� box 2-1/2"(64mm)
minimum depth
(supplied by others)
Address setting under resealable label
� �
Single gang blank cover plate and mounting screws,for use when
LED is not required to be externally viewed (supplied by others)
Mounting Reference, Single Gang Blank Cover Plate
O
O ! O °
Light pipe for
� LED viewing �
4-1/4" O O 4-1/2"
(108 mm) (114 mm)
�� .� � �.
Er ';� , i���r� 16F v,_5�<1�`::
� ,
0 0 °
O
2-1/2" �(723m1m)
(64 mm)
4090-9806,Trim plate for 4090-9807,Trim plate for 4090-9810 Mounting
semi-flush mounted box surface mounted box bracket, ordered
separately
NOTE: These mounting plates require mounting bracket 4090-9810.
Optional Trim Plates and Mounting Bracket for Visible LED
3 S4090-0001-10
� 1 • 1 ' 1 • • • •
Address setting is � �
at rear of housing
4090-9051
Encapsulated
Supervised IAM
�
��
�
Single gang electrical
box 2-1/2"(64mm)
minimum depth
(supplied by others)
� Single gang blank cover plate and
mounting screws (supplied by others)
Tyco is a registered tradeniar-k of�Tyco lnter�nntional Services GmbN and is used under license.Simplex,Xhe Simplcr[ogo,IDNet,and MAPNFT/I are trademarks of Tyco
Lnternutional L[d.and its affiliates and are used zuader license.
�3S i m p I Ex SimplexGrinnell LP Westminster• Westminster,MA•01441-0001•USA S4090-0001-10
o www.simplexgrinnell.com
OO 2011 Tyro.A!!righGr r�eserved.All s�eciftcalions and other•ir formation shown were curr�ent as o/document revision da[e and are si{bject[o change without notice.
��SimplEx Multi-Application Peripherals
UL, ULC Listed; FM, CSFM, IDNet Communicating Devices
and MEA (NYC) Approved* Model 4090-9002 Relay IAM
�
Individual Addressable Relay Module (Relay � o � o �
IAM):
• IDNet addressable control for use with Simplex°fire � � �
alarm control panel models 4100ES/4100U,4010ES,
4008, and 4010 � � �
• A single addressable point provides control and status � 4�mwex �
tracking of a Form"C"contact � ,., `�O
• Low power latching relay design allows IDNet p � ;�r.=�; ` � p
h � F
communications to supply both data and module power 'r°°°°°°°°
Compact, sealed construction: � o o �
• Enclosed design minimizes dust infiltration
• Mounts in standard 4"(102 mm)square electrical box
• Screw terminals for wiring connections 4090-9002 IDNet Relay IAM Package
(shown approximately 1/2 size)
• Visible LED flashes to indicate communications
• Optional covers are available to allow LED to be ' ' '
viewed after installation
UL listed to Standard 864 Communications IDNet communications, 1 address per
device
� _ � � Relay IAM Power Supplied by IDNet communications
Contact Ratings*(not rated for incandescent switching)
IDNet Relay IAMs allow fire alarm control panels to
control a remotely located Form"C"contact using IDNet Type Form C, SPDT
addressable communications for both data and module 2 A@ 24 VDC, resistive from listed
power. Typical applications would be for switching local Power-Limited fire alarm
power for control functions such as elevator capture,or 1 A@ 24 VDC, inductive supply
control of HVAC components,pressurization fans, Nonpower-Limited 0.5 A@ 120 VAC, resistive
dampers, etc.Relay status is also communicated requiring * Provide circuit fusing and transient suppression as
only one device address. required per application. DC inductive loads can typically
be diode suppressed; 120 VAC loads may require RC
• � � , networks or varistors,depending on device type. Refer to
Installation Instructions 574-184 for additional information.
Model Description Screw terminals for in/out wiring,
4090-9002 Relay IAM Wire Connections 18 to 14 AWG wire(0.82 to 2.08 mmZ)
Optional Trim Plates Up to 2500 ft(762 m)from control
panel
Model Description IDNet Up to 10,000 ft(3048 m)total wiring
For semi-flush Communications distance includin T-Ta s
4090-9801 Trim plate,galvanized Wiring Reference � g p �
mounted box steel,with LED viewing Compatible with Simplex 2081-9044
For surface window; includes Overvoltage Protectors
4090-9802 mounted box mounting screws
Dimensions 4'/e'H x 4'/8"W x 1 '/8'D
(105mmx105mmx35mm)
' Thisproducthasbeenap�xovedbytheCalifomiaStateFreN}arshal(CSFN�pursuar�to Housing Material Blackthermoplastic
Section 13144.1 of the Califomia Health and Safety Code.See CSFM Listing
73040026:223forallanral�levaluesarxVoroonditiais�iingmateri�presc-��tedinthis Mounting Plate Sheet metal,galvanized
doa�rr�,t.itissubjecttore-e�rinatia,,revision,andpossiblecancellation.P�eptedfor Temperature 32°to 120° F(0°to 49°C),
�-a�y o�r�w vor�o�trr�r,t o�aU�ia��-�a3.��E.a�d�t�o�,�r�r,��y r�
applical�le;cont2dya,rl«:alSlrrplexprodudsupplierforthelateststatus.Listingsand Range intendedforindooroperation
appr�ralsur,de�-SirrpexTimeReoorcic�-Co.aretneprq�ertyofTyoosafetyProduas Humidity Range Up to 93°/u RH at 100° F(38°C)
V�kstrririster.
S4090-0002-8 12/2012
� . . . .
�
�O
0
� 0
Address setting under � �
resealable label 0
��
� O O
�N0�w
� ,�w
�" .� � m
4"(102 mm)square box,2-1/8"
�// (54 mm)minimum depth, RACO
� 232 or equal(supplied by others)
4090-9002 Relay IAM
.�
�/ �� Double gang blank cover plate and mounting screws,for
' use when LED is not required to be externally viewed
�' (supplied by others)
Mounting Reference, Double Gang Blank Cover Plate
0 � � �
Light pipe for LED viewing
4-9/16" 4-5/16"
� �
(116 mm) DISCONNECT POViE6� GGONNECT�" �F � (109 mm)
CE�OdE C'R'd'�CIVG ,:i �,;
� � � 0
-9/16"(116 mm)� �-4-5/16"(109 mm)�
I
4090-9801,Trim plate for 4090-9802,Trim plate for
semi-flush mounted box surface mounted box
Optional Trim Plates for Visible LED
TYCO,SIMPLEX,and the product names[isted rrz khis material are marks arad/or registered marks.Clnauthorized use is sU�ictly pr�ohibited.
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4090-0002-8 11/2012
www.simplexgrinnell.com
�2012 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice.
�oSimplEx LifeAlarm Fire Alarm Controls
UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control from 4010, 4010ES,
MEA (NYC)Acceptance* 4100ES/4100U IDNet Communications, or Conventional NACs
�
Provides additional notification appliance circuit � �
(NAC) capacity with flexible operation modes and
power-limited design up to s Nacs
Four, Class B NACs are standard: � �
• Rated 2 A each for conventional reverse polarity aoos i�Net
24 VDC notification appliances and providing NAC Extender - - - -
multiple operation modes ==_==_==__= � �
• Can be selected to provide synchronization for
Simplex°visible notification strobe flashes �
• Capable of controlling TrueAlert non-addressable � optionai ioNet
notification appliances operating with SmartSync =__________ Channe�Repeater
two-wire control mode** ;-�-�--:� � �
Input control options: � �� � � � � a
, . � . -.�
; � `� ��
• IDNet addressable communications from a Simplex 2_Wire IDNet �. ` �
mode14010,4010ES,4100U,or 4100ES Fire Alarm Communications or ��� ��� ��.
ContTOl Panel** ' Fiber Optic IDNet ``�
• Or from one or two conventional 24 VDC NACs with � Communications or `�
multiple output control options '. � NAC Control
������������������������������������������������������������ , �
IDNet communications control benefits: -�_:
• Provides status monitoring and individual NAC control IDNet Fiber �
using a single address per 4009 IDNet NAC Extender Optic Transmitter
• Supports IDNet"Device Level"earth fault location
������������������������������������������������������������ � .
WALKTEST operation is available with either 4010(shown)or
input choice 4010ES/4100ES/4100U —
Internal 8 A power supply/battery charger: F�re Aiarm cor,troi Par,ei
• Charges internal batteries up to 12.7 Ah or up to 18 Ah Fire Alarm control Panel with
batteries in external cabinet conventional NACs
• Provides status monitoring of battery,input power,and 4009 IDNet NAC Extender Connection Reference Drawing
earth faults
. . .
• Rated 8 A for"Special Application"appliances;
including Simplex 4901,4903,4904,and 4906 Series ADA ComplianCe. Complying with the notification
horns,strobes,horn/strobes,and speaker/strobes requirements of ADA(Americans with Disabilities Act)
• Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is
Optional 4009 IDNet NAC Extender modules: available within the fire alarm control panel.When
additiona]power is required,a Simplex 4009 IDNet NAC
• IDNet Communications Repeater provides Class B or Extender can provide up to 8 A of NAC power with up to
Class A output eight, supervised reverse polarity NACs.
• IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility.The 4009 IDNet NAC Extender
available as Class B or Class X
can be mounted close to a compatible dedicated host
• Four additional Class B NACs,rated l.5 A for Special panel or can be located remotely for convenient power
Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple
appliance power connection options further increase location flexibility.
• Class A,Two Circuit Adapter Module
Additional Information.For addirional operarion detail
UL Listed to Standard 864 and application information,refer to Installation
� Instructions 574-181 and field wiring diagram 842-068.
.
IDNet communication fiber optic transmitters: ` u-cr�r�a��saoo�-�mzcam�sp�«��ar,��,��a�ytr�c��f«�a
State Fre N}arsh�(CSFM)pursuaM to Sedion 13144.1 of the C�ifomia H�Ith arid
• For applications requiring the data integrity available ��y�.����;,,����.21arara�ian�ev�uesar�orconditions
with fiber optic communications corioerning rreterial presented in this document.It is subjed to ree�rrina[ion,�s�a,,
and possible car�odlation.Po�pted fa use—Qty of NewYork Department of Buildings
• Available as Class B or Class X _�p�,�93E.Pdd;t;a�al�;stinysnroybeappl;cable;oor�tactyax�ocalSirrpleacprod,�t
• Mounts in standard six-gang electrical box supplie�'fa-thelateststatus.Listingsandapprovalsurxic-SirrpleacTirreReoorderCo.
arethe propertyof SirrplexGrinrx�l LP,V�kstrrinster.
External battery cabinet for 18 Ah batteries **4100Urequiresrevisionl1soflwareahigherfa-mrrpatibility.4010requiresrevision2
software a-hic�er fa-mrrpatibility.
S4009-0002-11 1/2013
� • • • • • • - • • •
IDNet Addressable Communications Compatible. Hardwire Control Applications. For applications
Up to ten(10),4009 IDNet NAC Extenders can be where an existing(or new)conventional NAC needs
controlled per 4010ES/4100ES/4100U IDNet additional power,the 4009 IDNet NAC Extender can be
communications channel;up to five(5)can be controlled controlled directly from the NAC. Either one or two
on tbe 4010 iDNet communications channel. Each output NACs,from either the same,or from different host fire
NAC can be individually controlled for general alarm ar alarm control panels,can be connected to control the 4009
selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control
address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for
be manually controlled from the host panel. IDNet more detail.)Alarms from the host panel will activate the
conYrolled extenders will inform the host panel of troubles four,4009 IDNet NAC Extender NACs(or optionally,
via lDNet communications.4010ES/4100ES/4100U eight NACs)to extend the alarm.
control panels control using multi-point rules,refer to The 4009 IDNet Extender monitors itself and each of its
data sheet S4090-O011 for details.
output NACs for trouble conditions, including earth
Optional IDNet Repeaters.IDNet communications can faults.Extenders wired to conventional NACs will
be repeated with the optional IDNet Repeater Module or indicate a trouble by opening the path to the NAC's
with the optional Fiber Optic Receiver Module.Up to 100 end-of-line resistor,but retaining the ability to respond to
of the IDNet channel points can be repeated once(refer to alarms. Individual troubles are also annunciated by LEDs
pages 3 and 5 for details). Repeated IDNet communications located on the 4009 IDNet NAC Extender main circuit
also support the"device level"earth fault location utility of board. (Refer to page 7 for more diagnostic information.)
the host panel.
. • .
Standard Models
Model Description
4009-9201
120 VAC input
4009-9202CA* 4009 IDNet NAC Extender with 4,Class B NACs and 8 A power supply
4009-9301 240 VAC input
" ULC listed model
Optional Modules (for on-site installation)
Model Description Comments
Additional four point NAC module, rated 1.5 A Special
4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum
power,Class B
4009-9808 Dual Class A adapter(for two NAC outputs) Select as required (4 maximum)
4009-9809 IDNet Repeater,output is Class A or Class B Select either an IDNet Repeater or a Fiber
4009-9810 Class B Optic Receiver as required;one transmitter
4009-9811 Fiber Optic Receiver Class A(IDNet), Class X(fiber) can connect to one receiver
4009-9805 Red Applique for door Select if required
2975-9801 Beige trim 1-7/16"wide(78 mm), use if required for
Semi-Flush Trim Kit
2975-9802 Red trim semi-flush installations
Battery Selection (select battery size per system requirements)
Model Description Comments
2081-9272 6.2 Ah Battery, 12 VDC
2081-9274 10 Ah Battery, 12 VDC Two batteries are required,24 VDC
operation
2081-9288 12.7 Ah Battery, 12 VDC
2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet,two
batteries are required, 24 VDC operation
External Accessories (select per system requirements)
Model Description Comments
4090-9105 IDNet Fiber Optic Class B operation Mounts in six-gang electrical box, refer to
4090-9107 Transmitter Class X operation page 4 for mounting details
4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4"W x 13-1/2"H x 5-3/4"D
(413 mm x 343 mm x 146 mm)
4081 Series End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details
2 S4009-0002-11 1/2013
• � • • •
Typical IDNet compatible devices
e
(Refer to individual devices for actual wiring
requirements,some wiring is not shown.)
i
�
■ �n�
I IDNet addressable communications channel,
pIfVIII�I��I101B0011111IfIIIItlVdtl�VOVBOVV��161111Vdl�lildllll �/shown Class B(Style 4)
IfIIVIVI��II�IB01B!lIIVIIIIIVVVV9V�B9VVVVVI91111lVIVIII�UU
Output NACs,four standard, Conventional NAC operation(horns)
_ eight with expansion option � �= �—�Select conventional
°��� °— or SmartSync
4100ES(shown) ==°== =-=== - �operation per NAC
or 4010ES/4100U/4010 � � �
Fire Alarm Control Panel �
SmartSync operation(horns and strobes)
4009 IDNet NAC Extender with ====_=__==_ -
optional internal IDNet Repeater Conventional NAC
� � operation(strobes)
Repeated IDNet Channel: ________°v
up to 100 devices maximum on repeater output, � � � ���
250 devices total on IDNet Channel °
����'__����:�
IDNet devices and additional 4009 IDNet NAC Extender(s)
NOTE: Up to ten (10)4009 IDNet NAC Extenders may be connected per 4010ES,4100ES or 4100U
IDNet channel, up to five (5)on the 4010 IDNet channel. IDNet communications can be repeated
only once (can pass through only one series connected repeater or one fiber optic receiver).
• • - • • . .
Two fiber cables,3000 ft Output NACs
4090-9105,Class B (914 m)maximum distance =__________
(Style 4)Output Fiber °°°°°°°°°°° � �
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Optic Transmitter
0
� � _
_.�_...
� � o
IDNet addressable communications �
� channel Class B(Style 4)or Class A
(Style 6),Class B shown Repeated IDNet Channel:up to 100 devices maximum
on repeater output,250 devices total on IDNet Channel
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Four fiber cables,3000 ft �
4010,4010ES, (914 m)maximum distance
4100ES,or 4100U Fire �I . . . . ___-__--__-
Alarm Control Panel -
24 VDC power for/ =_°______=_ �
fiber optic transmitters
4090-9107,Class A(Style 7) fl � �
Output Fiber Optic Transmitter � ��
°°°==°===°= � �
4009 IDNet NAC Extenders with optional Output NACs
internal IDNet Fiber Receivers
NOTE: Up to ten (10)4009 IDNet NAC Extenders may be connected per 4010ES, 4100ES or 4100U IDNet channel,
up to five(5)on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass
through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to
only one receiver in a 4009 IDNet NAC Extender.
3 S4009-0002-11 1/2013
. . . . . . . . . � . . . .
NAC Input Selections. The 4009 IDNet NAC The TrueAlert Notification Appliance product line
Extender can be selected to: includes addressable and non-addressable operation.
• Track input NAC operation or to provide a locally Non-addressable models are available with 2-wire
generated code, selectable per NAC input SmartSync operation or conventional 4-wire operation.
The following details apply to use with the 4009 IDNet
• If selected for local coding,NAC outputs can be either NAC Extender:
Temporal Coded or 60 Beats/min March Time Coded,
one code selection per extender(input NACs must be on • TrueAlert non-addressable models with SmartSync
continuous with Alarm) operation allow audible notification to be separately
• Addirionally,NAC outputs can be selected to provide controlled over the same wire pair that controls visible
the Simplex strobe synchronization signal. This signa] notificarion
will synchronize the flashes of synchronized strobes but . 4009 IDNet NAC Extenders can be selected to provide
will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet
(Strobes are for operation by noncoded NACs.) communications or conventional NACs
NAC input to NAC output control can be selected for • iDNet control allows output NACs to be individually
standard and optional NACs per the following table: selected for conventional or SmartSync operation
Conventional NAC Output Operation Options • With NAC input control, all output NACs are selected
Input A B C for either conventional or SmartSync operation
NAC 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 . Refer to data sheet 54009-0003 far TrueAlert
NAC 2 NACs 3&4,7&8 NACs 5-8 None Addressable operation details,contact your local
SmartSync NAC Output Operation Simplex product supplier for further information on
Input NAC Control Function specific TrueAlert notification appliances
NAC 1 Strobe Control
NAC 2 Horn Control All NAC outputs(1-8)
• • • � � • • � . •
Up to eight(8)output NACs total;hardwire control can be
selected to map NAC inputs to different combinations of
NAC outputs depending on system requirements
NAC 1 input � �
(see Note 1)
,� Conventional NACs
� = ========= - - - - �
� � With hardwire control,
� '°°� �'W' NAC outputs are all
� m Output conventional or all
------ ----- - "''` ' ' "`� ' ' NACs SmartSync operation
� ====°======
- � ___________
� 4009 IDNet NAC i �
i Extender i � � � i
Fire Alarm Control Panel i i �
aaW�
with Conventional NACs � � SmartSync operation i
� �---------------------- --'
i
i Class A operation,either mode,requires
NAC 2 input � 4009-9808 Dual Class A Adapter
(optional,see Note 1) i
� To additional 4009 IDNet NAC Extenders(up to four(4),
`---------} 4009 IDNet NAC Extenders per NAC);see Note 2
Notes:
1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required.
NAC 1 is"on-until-reseY'and NAC 2 is"on-until-silenced."
2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe
output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or,
if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected
for SmartSync operation for this function.
Refer to Installation Instructions 574-181 for additional information and application guidance
4 S4009-0002-11 1/2013
� 1 1 • � � • - • - •
120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz
Input 240 VAC Input(4009-9301) 1.5A @ 204-264 VAC, 50/60 Hz
Ratings Hardwire Control from External Conventional reverse polarity operation
NACs, Input Requirements 5 mA maximum; 16 to 33 VDC
Total Rating $A, Special Application appliances
6 A, Regulated 24 DC appliance power
Standard NACs 2 A each, Special Application or Regulated 24 DC appliance power
Optional NACs 1.5 A each, Special Application appliances
(requires 4009-9807) 1 A each, Regulated 24 DC appliance power
Special Application Simplex 4901,4903,4904,and 4906 Series non-addressable horns, strobes,
Output Ratings and combination horn/strobes and speaker/strobes(contact your Simplex
Appliances product representative for compatible appliances)
Regulated 24 DC Power for other UL listed appliances; use associated external synchronization
Appliances modules where required
Strobe Operation Up to 33 strobes per NAC can be synchronized;output NACs configured for
Simplex synchronized strobe operation are synchronized to each other
Auxiliary Output 500 mA @ 24 VDC nominal
Optional Modules Ratings
Input Power 70 mA @ 24 VDC,system supplied
IDNet Input, One Address Maximum distance from IDNet source is 2500 ft(762 m)
IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed
Module 250 per channel)
(4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m)
Total distance including"T-taps"is 10,000 ft(3048 m)
Class A loop maximum distance is 2500 ft(762 m), no"T"taps
Fiber Optic Receiver Modules
Input Current 4009-9810, Class B,65 mA @ 24 VDC, system supplied
4009-9811,Class X,80 mA @ 24 VDC,system supplied
IDNet Output Specifications Same as those for Repeater Module(see above)
Fiber Optic Transmission Distance 3000 ft(914 m)maximum
General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6)
Operating Temperature 32°to 120° F(0°to 49°C)
Operating Humidity Range 10%to 90%RH from 32° F to 104° F(0°C to 40°C)
Wiring Connections" Terminal blocks for 18 AWG(stranded)to 12 AWG(solid)
� - • • • - •
Input Voltage 18.9-32 VDC from compatible listed fire alarm supply
Input Current 4090-9105, Class B,30 mA @ 24 VDC
4090-9107, Class X,35 mA @ 24 VDC
Multimode,graded index, 50/125um,62.5/125�m, 100/40�m,or 200 um
Fiber Optic Connections and cable Type ST connectors
requirements 4090-9105, Class B operation,two fiber cables required
4090-9107, Class X operation,four fiber cables required
Module Size(with mounting bracket) 6-13/16"W x 3-3/4" H x 1-1/8"D(173 mm x 95 mm x 29 mm)
Green LED flashing=transmit
On-board Status Indicators Red LED flashing =receive
Separate red LED on 4090-9107=Class X receive
Communications Simplex IDNet
Fiber Optic Transmission Distance 3000 ft(914 m)maximum
Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid)
Operating Humidity 10%to 90%RH from 32°to 104° F(0°to 40°C)
Operating Temperature 32° F to 120° F(0°to 49°C)
*Metric wire equivalents: 18 AWG=0.82 mmZ; 12 AWG=3.31 mm2
5 S4009-0002-11 1/2013
� 11 • � � • - • • • • � • •
Cabinet depth
la 16-1/4"(413 mm) '� 4-1/4"(108 mm)
�-
10-29/32"(277 mm) Door,5/8" �
a0 OO � � (16 mm)thick�a i
8 O �� �� � � � I o
0 0 0 0 0 0 0 0 �
i
Optional Class A 4009-9807 Additional Four � 13-1/2"
adapter modules point module(shown with ; (343 mm)
� Class A adapters) 0 Exposed cabinet ;
dimension for ,
!� System Module � � semi-flush mount ;
L�f � 1"(25.4 mm), ; Knockouts for screw
IDNet repeater or � 1-3/8"(35 mm)with � or nail mounting holes
Fiber optic receiver semi-flush trim
8 � CJ
o � �
OO OO
�
�-----------------------------� � I
� � � I
� � � I
� 12"(305 mm) -' �
� � I
I � � �
��. Battery location,no conduit entry or wiring in i �
i this area(12.7 Ah battery outline shown) � � i �
i � �i i i
Semi-flush trim option
Non-power limited wiring area(AC input) 1-3/16"wide(30 mm), ��
3/8"(9.5 mm)thick
Wall surface reference for semi-flush mount�
NOTE: Recommended conduit entrance varies with module selection. Refer to general installation
instructions 574-181, specific module installation instructions, and to field wiring diagrams
842-068 before locating conduit entrance.
� 11 • � � . - . • � . . � -
� Optional red applique
(4009-9805)
r.`../
� 1 1• � - ` � � � '
6 S4009-0002-11 1/2013
� 1 ' 1 • 1 ' 1 � • - • • • � • •
Surface mount box: _�, o 0 0 0 0 0
Simplex model 2975-9217
(ordered separately)
Flush mount masonry box: O o O o O o
use 6-gang box, RACO#960,2-1/2"deep �� o 0 0 0 0 0
(64 mm),or RACO#965, 3-1/2"(89 mm) O
deep, or equal (supplied by others)
0 0 ° o ° ° o ° O
Flush mount ganged boxes:� _ _ O
' o
use 6-gang box, 1-1/2"(38 mm) � � � �
minimum depth;six, RACO#400 C � � � , '� � O O C
or equal, (supplied by others) � . � ' � �
' •
o �
0 0 0 0
0 0 0 0 0 o IDNet fiber optic transmitter:
4090-9107, Shown,Class A(Style 7)output
4090-9105, Not shown, Class B(Style 4)output
INSTALLATION NOTE:
Fiber optic cable bend radius should be 2"(51 mm)
minimum,or per Manufacturer's specification.
0 0 0 0 0 0
Six-gang blank cover plate Mulberry Metal
Products 97156 or equal(by others)
- � . . . LED Status Indicators are provided for the following:
Power-up Self-Diagnostics.Upon power-up,the • Each NAC(standard and optional)has a dedicated
4009 IDNet NAC Extender tests each module and yellow LED that:
performs earth fault diagnostics. Trouble conditions are — During supervision provides a slow flash to indicate
communicated to the host control panel and are also a short circuit condition and a fast flash to indicate
displayed on diagnostic status LEDs in the 4009 IDNet an open circuit
NAC Extender.When connected via lDNet — During an alarm,the LED follows the NAC output
communications,detailed status information is available (on steady or flashing with coded output)
at the host.When controlled with conventional NAC
inputs,common troubles are signaled by providing a • FOUr, general status yellow LEDs provide nine
polarized open circuit that disconnects the NAC wiring separate indications listed in priority of urgency.As a
from its end-of-line resistor but still allows a reversed trouble is eliminated, any remaining trouble(s)will
polarity alarm to be received. then be indicated until the 4009 IDNet NAC Extender
is returned to normal operation.
Door Mounted Reference Label. The 4009 IDNet
NAC Extender has a detailed programming and • AC power status is indicated by a green LED that is
diagnostic label inside the front door that provides a quick on when AC is normal. During low AC(brownout)
reference for both installation and checkout. conditions or with no AC,the LED is off. Additional
power and battery status is indicated by the general
status LEDs.
7 S4009-0002-11 1/2013
� 1 1 • � � • - •
Step 1. Calculate Basic Extender Batterv Requirements (minus NAC loads)
Panel, NAC Options, and Auxiliary Power(underlined model numbers are optional modules)
Model Descript ion Supervisory Actual qlarm Current Actual Alarm
Current Supervisory
4009-9201 120 VAC input
Basic Panel 85 mA 85 mA 185 mA 185 mA
4009-9301 240 VAC input
4009-9807 Additional Four Point NAC 40 mA + 40 mA +
4009-9808 Dual Class A Adapter(no additional current) — — — —
Auxiliary Power Output (500 mA + (500 mA
maximum) maximum) +[A1]
Basic Panel Supervisory Current = [S1]
Basic Panel Alarm Current =[A2]
Step 2. Calculate IDNet OutpUt Module and Device Current(if used)
4009-9809 IDNet Repeater 70 mA 70 mA
4009-9810* Fiber Optic Receiver,Class B Select one per 65 mA + 65 mA +
Extender
4009-9811* Fiber Optic Receiver,Class X 80 mA 80 mA
IDNet Devices(connected to Repeater or Receiver above), Total devices Total devices
0.7 mA each, maximum of 100 x 0.7 mA each + x 0.7 mA each +
�Note: IDNet Fiber Optic Transmitter IDNet Module Supervisory Current [S2] _
current is supplied from the host fire
alarm control panel IDNet Module Alarm Current =[A3]
Maximum Available Current =8 A*
Step 2. CalCUlate Available NAC Current Subtract Auxiliary Power Output -[A1]
Subtract IDNet Module Current -[A3]
�8 A for Special Application Appliances;6 A for Regulated 24 DC Appliances Available NAC Current =[A4]
Step 3. Calculate Actual NAC Loadinq (Limited to Available NAC Current per Step 2.)
NAC Type NAC Circuit# NAC Alarm
Current
Circuit 1 +
Circuit 2 +
Standard Panel NACS,2 A maximum per NAC
Circuit 3 +
Circuit 4 +
Circuit 5 +
Optional Four Point NAC Module, 1_5 A maximum Special Application rating, Circuit 6 +
1 A maximum Regulated 24 DC rating, per NAC Circuit 7 +
Circuit 8 +
Total Actual NAC Load Alarm Current =[A5]
Step 4. Calculate Total Supervisorv Current
Total Supervisory Current=Basic Panel Current[S1]+ IDNet Module Current[S2]_
Step 5. Calculate Total Alarm Current
Total Alarm Current= Basic Panel Current[A2]+ IDNet Module Current[A3] +Actual NAC Current[A5] _
TYCO,SlMPLEX,and the product names disted in this niaterial a��e marl s and/or�registered mar�ks.Una�tithorized use is strictly pi�ohibited.
�05 i m p I Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4009-0002-11 1/2013
www.simplexgrinnell.com
�2013 Tyco Fire Protection Praducks.Ali nghts reserved.A!!speci�ications and other in%rrynafion shown were c�Arrent ns of document revision date and are subject to char�ge without notice.
�oSimplex TrueA/ert° Multi-Candela Notification Appliances
UL, ULC, CSFMListed; FMApproved; SmartSyncT"' Operation Audible/Visible Notification
MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable
� __ �__-====— –
` —.�� II;9IImil E — 5. �,:;
. . � . � . pp II„ ! II ��
eff cient ellectron�o ntandthigh output xe onh II �� ��
strobe, available for wall or ceilin mount: - -
9 �� ��
• Operation is compatible with ADA requirements(refer ° . - - � � `
to important installarion information on page 3) � o
• Ru ed hi h im act flame retardant thermo lastic
�� , g P , P
- —
. . � I !
hous�ngs are available m red or white with clear lens y� � � �
I
Operates over a two-wire SmartSync circuit to II��� _ ______- �'
provide: -
• Horns that are controlled separately from strobes on the
same two-wire circuit _-�
• "On-until-silenced"and"on-until-reset"operation on m � �
�
the same two-wire pair _;�;
�
• SmartSync horn activation of Temporal pattern,March
� � �� � I �� y
Time pattern(at 60 BPM),or on continuously � � I �
• Strobe appliances on the same circuit operating at a � m i ��
synchronized 1 Hz flash rate �� _�r
�
• Operation requires connection to a compatible "
SmartSync operation NAC or to SmartSync Control Wall and Ceiling Mount A/Vs
Module(SCM)4905-9938
� - • .
Wall mount A/Vs features:
• Wiring terminals are accessible from the front of the Multi-Candela TrueAlert ANs with horn and
housing providing easy access for installation, synchronized strobe provide convenient installation
inspecrion,and testing to standard electrical boxes.The enclosure designs are
both impact and vandal resistant and provide a convenient
• Covers are available separately to convert housing color strobe intensity selection. Since each model can be
• Optional UL/ULC listed sound damper for locations selected for strobe intensiry output,on-site model
requiring attenuation of 5 to 6 dBA(stairwells, small inventory is minimized and changes encountered during
rooms,highly reverberant areas,etc.) construction can be easily accommodated.
Optional adapters and wire guards: Wall mount A/V housings are a one-piece assembly
• Wall mount A/V adapters are available to cover surface (including lens)that mounts to a single or double gang,or
mounted electrical boxes and to adapt to Simplex° 4"square standard electrical box. The cover can be
2975-9145 boxes quicldy removed(a tool is required)and covers are
• UL listed red wire guards are available for wall or available separately for color conversion.
ceiling mount ANs* Ceiling mount ANs install using standard 4"electrical
Visible notification appliance (strobe): boxes. Color choice is determined by model number.
• 24 VDC xenon strobe; intensity is selectable as 15, 30, � � . �
75,or 110 candela with visible selecrion jwnper secured
behind strobe housing During installation,a selection plug at the back of the
• Regulated circuit design ensures consistent flash output housing determines the desired strobe intensiry. An
and provides controlled inrush current attached flag with black letters on a highly visible yellow
background allows the selected intensity to be seen at the
• Listed to UL 1971 and ULC 5526 side of the strobe lens.
Audible notification appliance (horn): � Refertopage2forguardlisting.ThisproducthasbcenapprovedbytheCalifomia�ate
• Low current,24 VDC electronic horn with harmonically Fre N�rshal(CSFN�pursuant to Sedion 13144.1 ofthe Califomia Health and SaFely
Code.See CSFM Listing 7125-0026:317 fa-allw✓able val�s arxVa coriditiais corioerning
rich sound output suitable for either steady or coded rreterial preserrted in tftis docurrent.It is subjed to reexarrination,re��a,,and pcssible
operation(Temporal or 60 BPM March Time pattern) ��Iation.Pca�tedfause—QtyofNewYalcDe{�rtmentofBuildings—NFA.'35-93E
Refer to page 2 fa listing stat�s of voire guards.Additional listirgs rray be applicable;
• Listed to UL 464 and ULC 5525 cont2ctyourla�Sirrplexprak�ctsupplierforthelateststatus.Listirx�andap�xovals
urxier Slrrplex Tirre Ft�a-der Co.are the properiy�Tyco SaFety Products Westrririster.
'" Sirrplex rrulti-c�ndela Srrnrt5)rtic tvoo-w+re horti/strobe appliance operation is proteded
urxiPx one a mxe of the fdlo�,ning U.S.Paterrt Narri�ers:5,559,492;5,622,427;
5,865,527;5,886,620;6,281,789;6,954,137;7,005,971;and 7,006,003.
S4906-0002-5 9/2009
. . - � . . . . . . .
Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to
occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on
of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced
A117.1;the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as
ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is
Americans with Disabilities Act(ADA). "on-unril-reset."
. - . . . -
. . .
Multiple Strobes.When multiple strobes and their • 4006,4008,4100U,and 4010 Fire Alarm Control
reflections can be seen from one location, synchronized Panels(refer to individual product data sheets for more
flashes reduce the probabiliry of photo-sensitive reactions information)
as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet
random flashing.The multi-candela strobes of these A/Vs S4009-0002)
are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938 (refer to
NAC. data sheet S4905-0003)
Additional SmartSynC compatible notification
appliances include separate horns and combination
. • .
horn/strobe notification appliances.
Multi-Candela A/Vs
Model Mounting Housing Color "FIRE"Lettering Description
4906-9127 Red White
Wall Horn with Multi-Candela Strobe;strobe intensity selectable as:
4906-9129 White Red
15, 30, 75,or 110 candela; operates with SmartSync two-wire
4906-9128 Red White control
Ceiling
4906-9130 White Red
Wall Mount A/V Accessories
Model Description Dimensions
4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D
surface mounted boxes (136 mm x 133 mm x 41 mm)
4905-9940 White depth with strobe=4-3/8"(111 mm)
4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick
retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm)
2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D
(200 mm x 130 mm x 70 mm)
Optional Sound Damper; package of 20;field installed adhesive backed
4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm)
NOTE:After Sound Damper installation, measure sound level to ensure with 0.31"(8 mm)sound opening
compliance with applicable code requirements
SmartSync Control Module
Model Description Dimensions
4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4"x 4-1/8"x 1-1/4"D
(102 mm)square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm)
Replacement Covers for Wall Mount ANs
Model Description Dimensions
4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D
4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm)
Wire Guards and Ceiling Mount A/V Adapter
Model Description Dimensions
4905-9961" Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D
or surface mounted boxes (154 mm x 154 mm x 79 mm)
4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3"
(216mmx156mmx76mm)
4905-9928� Ceiling Red Adapter Plate, required to mount guard to surface 9"x 7"
Mount mounted electrical box (229 mm x 178 mm)
4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4"x 6-7/8"x 1-1/2"deep,
4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm)
`UL listed by Space Age Electronics Inc.
2 S4906-0002-5 9/2009
� . - .
Wall Mount or Ceiling Mount, Common Specifications
Rated Voltage Range Regulated 24 DC;see Note 1 below
Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC
Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C)
Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per
terminal for in/out wiring
Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate
Model Type Wall Mount Ceiling Mount
Horn Output Sound Type(see Note 2) Steady Coded Steady Coded
Ratings
(see Note 2 for Reverberant Chamber Test, g6 dBA 82 dBA 87 dBA 83 dBA
polar dispersion per UL 464 @ 10 ft(-3 m)
reference) Anechoic Chamber Test,per
ULC S525 @ 3 m(-10 ft) 88 dBA 94 dBA 90 dBA 98 dBA
Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm)
Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd
Wall Mount Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA
Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA
at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA
Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm)
Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd
Ceiling Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA
Mount
Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA
at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA
NOTES:
1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices forthe Hearing Impaired,
changes effective May 1,2004.This voltage range is the absolute operating range.Operation outside of this range may cause
permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the
NAC under worst case conditions.
2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter
reading on a"fasY'setting. Polar dispersion per ULC S525 testing= -3 dBA at+/-40°off-axis;-6 dBA at+/-50°off-axis.
3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage
and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the
effective value of a varying current waveform.)
. • . •
�� �� ��
Mounting is compatible with �
single gang,double gang,and
� o 0
a"(�02 mm)square boxes, �', � 1 ° � �) r IMPORTANT!WALL MOUNT
1-1/2°(ss mm)deep,by others — INSTALLATION HEIGHT REFERENCE
0 0 0
Optional 4905-9838
Sound Damper,field attached Bottom of lens
to attenuate sound 5 to 6 dBA � � � IS elthel'eVen
with,or slightly Electrical
� o o � O above bottom box outline
Wiring access hole O of compatible�
tt ; � boxes
Wiring terminals for �'� ' 0 1
SmartSync operation __ I
Mounting Holes:
I , NFPA 72 requires 80"(2.03 m)
YPm�w°�'II ��� � s�gle gang(2) that the entire lens minimum
� --� -� be not less than
�C,, ooueie gang(3) g0"and not greater
� � � � than 96"above the
Tr Insparent housing finished floor
and lens assembly
Intensity selection
plug,accessible only
from rear of housing; 15
� � � � factory setting is 15 cd
Removable cover Strobe intensity
(tool required) viewing slot
3 S4906-0002-5 9/2009
. . � . . .
Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate,
surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box
Four mounting clamps included,two each side
CC - -
�'� i o
/ ° Ceiling reference, ,
flush mounted box
o �
Optional 4905-9915/-9916 Adapter,
recommended for surface mounted box
Wiring terminals are Optional 4905-9927
� located behind the housing Red Wire Guard
� � � � End View
m m I —------------�
Strobe intensity viewing slot
m m Intensity selection plug, ;
� accessible only from rear of lens �
housing;factory setting is 15 cd �
• • � • • • • � • •
Surface Mounting Reference
2975-9145 Box with Optional Adapter Skirt
° and Optional Wire Guard
� Surface mount conduit and
o box shown for reference
4"(102 mm)square � ,
TM°°°°°^-� �� 0 box profile, 1-1/2" �----
� (38 mm)deep �
Optional I �
O O 4905-9961
�
�
— — Wire Guard �
�
q/V -----
� o � � W �
4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt,
O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red;
(shown here for reference only, 4905-9940,White(conduit knockouts
4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides)
Tyco is a registered tr•acfemark ofTyco Indernational Services GnsbH and is used under license.Simplex,the Simplu logo,/DNet, TrueAlert,and SenartSync are erademarks of
Tyco I�zternatro�:al Ltd.ancl its afJiliates and are used under lrcense.NFPA 72 and Nadonal Fir�e Alarm Cocle are trademarks ofPhe Narioreal Fire Protection Associatiwi(NFPA).
�3 Simplex Tyco Safety Products Westminster• Westminster,MA•01441-0001•USA S4906-0002-5 9/2009
� www.tycosaferyproducts-usa-wm.com
C 2009 Tvco Safety Prroducts Weshninstee A!!nohts reserved.A!l spec�icarions and other inforn�alion shown were curT�ent as of docurnent rwision clate arad are subject to change without nodce.
��Simplex TrueAlert° Multi-Candela Notification Appliances
UL, ULC, CSFM Listed; Weatherproof Notification Appliances (non-addressable)
FM Approved* Wall Mount Visible Only (V/O) and Audible/Visible (A/V)
� __
Weatherproof 24 VDC notification appliances for ��,.� ���
extended temperature and extended humidity �%�� ��'�
operatiorr. —-— . � r �— -�
• NEMA 3R rated enclosure with ratings for indoar or _ � � �
outdoor applicarions � _
• Rugged,high impact,flame retardant thermoplastic —�-- —
housings are available in red or white with clear lens
• Red housings are for indoor or outdoor applications __- -
and provide iTV light stable color � °'°°"„
• White housings are for indoor applications with
limited UV light exposure --- -� rn ��
• Mounting is to matching weatherproof boxes �
(required),ordered separately - � � �, �
• Wiring terminals are accessible froin the front of the � � �—
housing providing easy access for installation,
inspection,and testing
Agency listings reference: �I
• UL listed to Standard 1638 for outdoor applications � �
with strobe rated at 75 cd(WP75) �� ° � °
• UL listed to Standard 1971 for indoor applications ��
with strobe intensity selectable as 15,60,or 75
candela;indoor applications are compatible with ADA
requirements(refer to important installation
information on page 4) Weatherproof A/V(top)and Strobe(middle), side view of
A/V on Weatherproof Mounting Boxes (bottom)
• Separate models are ULC listed to Standard 5526
(strobes)and S525 (horns)for outdoor applications � - . .
with strobe intensity selectable as 5,20,or 30 candela
(available in red only) Weatherproof multi-candela TrueAlert appliances
provide V/O and AN SmartSync operation for indoor and
Operation details: outdoor, extended temperature and extended humidity
• A visible intensity selection jumper is secured behind applications. The enclosures are impact and vandal
the strobe housing resistant and provide a convenient strobe intensity
• Polarized input allows connection to comparible selection. Since each model can be selected for intensity
reverse polarity,supervised notification appliance output,on-site model inventory is minimized and changes
circuit(NAC) encountered during construction can be easily
accommodated.
• Regulated circuit design ensures consistent flash
output and provides controlled inrush current • � - •
• A/V appliances have an efficient electronic horn During installation,a selection plug at tbe back of the
Synchronized strobe compatibility: housing determines the desired strobe intensity.An
• Simplex�fire alarm control panels and NAC attached flag with black letters on a yellow bacicground
Extenders when selected to provide strobe allows the selected intensity to be seen at the side of the
synchronization or SmartSyncTM two-wire control** strobe lens.
Separate strobe Synchronization Modules or "�s product has been appraved bythe Califomia State Fre Nprshal(CSFfv�pusuant to
� Section 13144.1 of the Califomia H�Ith and Safety Code.See CSFM Listing
SmartSync Control Modules(SCMs)that convert 7125-0026331fa-allo�✓adevaluesarxVaooriditia�scorioeiningrreteri�presentedin
conventional NAC inputs to a Smartsync output tr�s doa�m�,t.it�s s�,��ct to��xa�;nat�«,,�s�or,,ar,d��e ca�iat�«,.
Ptiditional listirx�s rrey be applic�le;o�ntact your local Sirrplex p-oduc[supplier fa the
SmartSync two-wire operation provides: ��������"'�a�aa�-°�isU"a�-s�"�e"r"'e�-a�-�°.azetr��-°p��'
of Tyoo Safety Roduds V�kstrrinster.
• Horns controlled separately from strobes on the same � �;,,p���„it;-�rx�asrrortsy„ct,,,A.w;r�n�,��tro�e�;ar�op�t;o,,;s���d
two-wire circuit, activated as Temporal pattern,March urxleraieorrroreofthefdlo,ningU.S.PaterrtNirrt�ers:5,�s,492;5,s22,a2�;
Time pattern(at 60 BPM),or on continuously 5,se�,�2�;5,ass,620;6,2s�,�ss;s,954,137;�,00s,971;and 7,006,00s.
S4906-0010-2 12/2009
. . - � . . . . . .
Proper selection ofweatherproofnotification is dependent SmartSync two-wire control is available from:
on occupancy, location, local codes,and proper applications . 4006,4008,4100U,and 4010 Fire Alarm Control
of:the National Fire Alarm Code(NFPA 72),ANSI Panels(refer to individual product data sheets for
A117.1;the appropriate model building code: BOCA, more information)
ICBO,or SBCCI;and the application guidelines of the . 4009 IDNet NAC Extenders(refer to data sheet
Americans with Disabilities Act(ADA). Requirements may
differ from indoor appliance applications,contact your local S4009-0002)
authoriYy having jurisdiction(AHJ)to assist in determining • SmartSync Control Module(SCM)Mode14905-9938
requirements. (refer to data sheet 54905-0003)
• Addirional SmartSync compatible norification
• • • appliances include separate horns and combinarion
SmartSync operation mode allows a two-wire circuit to horn/strobe notification appliances.
provide the ability to activate both the horn and strobe on
the same NAC and then allow the horn to be silenced
while the strobe remains flashing. The horn operates as
"on-until-silenced"while the strobe operation is
"on-until-reset."
. . .
UL Listed TrueAlert Weatherproof Multi-Candela Notification Appliances
"FIRE" UL 1971 UL 1638
Model Type Housing Lettering Description Intensity Intensity
Rating Rating
4906-9105 Red White
Strobe(V/O) 75 cd
4906-9106 White Red UL listed weatherproof appliance with multi-candela 15,60,
4906-9131 Red White strobe; requires weatherproof box below or 75 cd (setting
Horn/Strobe WP75)
4906-9132 �A�V� White Red
ULC Listed TrueAlert Weatherproof Multi-Candela Notification Appliances
Model Type Housing `�FIRE" Description ULC Intensity Ratings
Lettering
4906-9113 Strobe(V/O)
Red White ULC listed weatherproof appliance with multi-candela 5,20,or 30 cd
4906-9143 Hor(��j be strobe; requires weatherproof box below
Wall Mount Weatherproof Boxes (Required)
Model Description Dimensions
4905-9828 Red 5-1/2"H x 6-1/8"W x 1-5/8"D
Surface Mount Weatherproof Mounting boxes (140 mm x 156 mm x 41 mm)
4905-9829 White
Aftermarket Red Bilingual (French/English) Covers (for field installation)
Model Description
4905-9832 Red strobe(V/O)cover
White"FEU/FIRE"lettering
4905-9833 Red horn/strobe(A/V)cover
Sy1tCh1'0111z8t1011 MOdul@ R@f@P@11C@(refer to data sheet S4905-0003 for additional information)
Model Description Dimensions
4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16"
in/out 18 AWG(0.82 mm )wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm)
4905-9922 Class A requires 10 mA for power
4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4"x 4-1/8"x 1-1/4"D
4"(102 mm)square box (102 mm x 105 mm x 32 mm)
2 S4906-0010-2 12/2009
. - , .
Rated Voltage Range Regulated 24 VDC;see Note 1 below
Flash Rate 1 Hz; Up to 24 synchronized strobes maximum per NAC
UL 1971 Listed Rating 32°to 122° F(0°to 50°C);selectable 15/30/75 cd
Temperature UL 1638 Listed Rating -31°F to 150°F(-35°C to 66°C);75 cd rating
Range
ULC S526&S525 Listed Rating -40°F to 150°F(-40°C to 66°C);5/20/30 cd rating
Humidity UL 1971 Listed Rating 10%to 93°/o,at 100° F(38°C)
Range UL 1638, ULC S526, & ULC S525 up to 98%,at 104°F(40°C)
Wiring Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mmz to 3.31 mmZ);two wires per
terminal for in/out wiring
Horn Output; Models 4906-9131, 4906-9132, &4906-9143; UL� ULC Ratings as noted
Output Sound Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate
Horn Output Voltage 16 VDC 24 VDC 33 VDC
Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded
@ 10 ft(3 m) UL 464 Reverberant Chamber 80 dBA 76 dBA 83 dBA 79 dBA 86 dBA 81 dBA
(see Note 2) ULC S525 Anechoic Chamber 96 dBA 96 dBA 99 dBA 99 dBA 101 dBA 101 dBA
Maximum RMS Current Ratings (see Note 3 below)
UL 1971 Ratings(32° F to 122° F) UL 1638 Ratings 75 cd(WP75)
Model Intensity Selection/Temperature 15 cd 60 cd 75 cd 32°F to 150°F -31°F to below 32°F
(0°C to 66°C (-35°C to 0°C)
V/O Models 4906-9105&4906-9106 77 mA 192 mA 231 mA 189 mA 273 mA
A/V Models 4906-9131 &4906-9132 91 mA 204 mA 249 mA 205 mA 277 mA
ULC S526/S525 Ratings per Intensity Selection
Model 5 cd 20 cd 30 cd
V/O Model 4906-9113 115 mA 270 mA 295 mA
A/V Model 4906-9143 125 mA 275 mA 322 mA
NOTES:
1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL 1971 and UL 1638.This voltage range is the absolute
operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the
lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions.
2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level
meter reading on a"fasY'setting. Under the same test conditions, coded horn output"peak"sound level readings are typically
4 dBA higher.Anechoic horn output ratings are typically more representative of actual installed sound output
3. Currents of A/Vs are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are
constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean
square and refers to the effective value of a varying current waveform.)
� • • • • • •
4-11/32"(110 mm) 1_2�/32�� pptional Bilingual
total depth (42 mm) Covers field installed
�5-3/8"(137 mm)� f. . o+p� — — )
e�
7
5-17/32" ��
O (140 mm) 1��� ��f°,3�
D
total height
�' �' � � � 4-1/2„ 4905-9832
0
� (114 mm} Strobe Cover(red)
6< �_. !.. ..! a...a�.w ��
� �
5-9/16"(141 mm)
� �C�D[��G3� ,
between mounting holes 4905-9833
6-1/8"(156 mm) A/V Cover(red)
3 S4906-0010-2 12/2009
. . . � . . .
NOTE: For detailed installation information,refer to Installation instructions 579-857 for UL listed products,and Installation
instructions 579-885 for ULC listed products.
Perimeter gasket,
pre-installed Knockouts top, bottom,sides,and back; 5 total
Cover to mounting box
mounting screws(3)� Weatherproof mounting box(required):
O 4905-9828, Red;4905-9829,White
1
Housing(A/V shown) �
�
Housing to mounting t o � Strobe intensity viewing slot
box screws(2) o� �
° 3 Intensity selection plug,accessible
� � �� only from rear of housing:
/ � -------- WP75
�„� _ _--�U"-- UL Listed Models:
Models 4906-9105,4906-9106,
�� 4906-9131, and 4906-9132 ;factory
� setting is WP75,the UL 1638,
75 cd rating
Three(3)cover attachment tabs
�5� ��.___r located bottom, left and right side 30 ULC Listed Models:
Models 4906-9113,4906-9143;
Standard cover factory setting is 30 cd
(A/V shown) Internal cover gasket
is pre-installed
Polar Light Dispersion Reference,Each Intensity Selection;
Percent of Rated Light Output at 77°F(25°C)
IMPORTANT! INDOOR WALL MOUNT Vertical Dispersion Horizontal Dispersion
INSTALLATION HEIGHT REFERENCE Angle UL 1971 Typical Angle UL 1971 rypica�
Below Minimum Output from Minimum Output
l�cis Auis
0 100°/ 322°/ 0 100°/ 320%
5 90°/ 217°/ ±5 90% 214%
10 90°/ 168% ±10 90% 177%
T � 15 90°/ 179°/ ±15 90% 175%
I 20 90°/ 210% ±20 90% 174%
$��� (2.06 m) 25 90°/ 184°/ ±25 90% 170%
NFPA 72 requires that the minimum to so so°i �as�i ±30 �s°i 169%
entire lens be not less than $0" mounting tabs ss ss°i ��z°i ±ss �s°i �s�i
and not greater than 96" ao 46% 189% ±ao �5i 151%
above the finished floor 45 3a�i zos°i ±4s �s°i 138%
50 27% 152% ±50 55% 130%
55 22% 166% ±55 45% 121%
60 18°/ 166°/ ±60 40% 117%
65 16°/ 164% ±65 35% 109%
70 15% 163% ±70 35% 105%
Horizontal Disqersion Vertical Dispersion �5 13% 159% ±75 30% 98%
80 12% 138% ±80 30% 90%
top -9 dB top g5 12% 113% ±85 25% 78%
-6 dB left side -6 dB right side -6 dB @75° g0 12% 88% ±90 25% 67%
-6 dB -3 dB @60°
-3 dB @85° WP75 Intensity Selection Light Output Reference
-3 dB @75o O on-axis On- Vertical, Horizontal,
@65° pn-axis(0°) 1(0°)rated Angle ��s Below Auis LeftlRight of Auis
rated output I output 0° 45° 90° 45° 90°
minimal UL 1638 Minimum
A/V Sound Dispersion per ULC S525 loss Candela Rating(over 75 35 10 32 15
anechoic testin erformed at 3 m 10 ft temperature range)
� J p � ) � Tvpical Candela
-1 dB bottom at 77°F(25°C) 2�5 103 24 94 39
Tyco is a registered trademark�f Tyco Tnternational Services GmbH and is used u�ider�license.Simplex,the Simplex logo,TDNet,TrueA[ert,and Smar�tSyrzc are tr�adenzarks of
Tyco International Ltd.and its aJfiliates aad are used�inder liceiase.NFPA 72 and NaXional Fire Alann Code are registered trademarks of the National Fire Protection
Associakron(NFPA).
�3Simplex Tyco Safety Products Westminster• Westminster, MA•01441-0001•USA S4906-0010-2 12/2009
� www.tycosafetyproducts-usa-wm.com
C�2009 Tyco Safety Products Weshninster.Al!rights reserved.A!/speciJicurions und other i�fonua6on shown were current us of document revision date and are subject to change without nofice.