HomeMy WebLinkAboutA13-0024 SIMPLEX PROPOSAL.pdf Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(a�COMCAST.NET
WWW.SHANERLIFESAFETY.COM
Encore Electric contact is RJ Vik
R. J. Vik
Encore Electric, Inc.
970-471-0800 cell
970-949-9277 office
970-949-9280 fax
rj.vik _,EncorcElectT-ic.com
Thul Electronics contact is Ron Davidson
970 949 4638
ron a�thulelectronics.com
Vail Resort Project contact is Bob Norris
Robert C. Norris
Manager-Vail Mountain Security
970-754-3055
RNorris(a�vailresorts.com
SimpleXGrinnell contact is Glen Williamson
Sales
970 556 7796
gwilliamson@siinplexgrinnell.com
Scope of Work:
This is a split installation with two prime contractors with parts and smarts for the Fire
Alarm System through SimplexGrinnell.
This will basically be a one for one replacement throughout the building with a few
device adds (duct detectors, strobes)where needed. The system backbone will be
upgraded to the SimplexGrinnell 4100ES FA panel series.
Far the Vail Resorts portion: Encare wil] do the install with SimplexGrinnell (SG)
providing, installation, fire alarm (FA) equipment,programming and testing with AHJ
and owner approval at One Vail Place for Vail Mountain Security. Simplex/Encore will
handle the retail areas, garage,panel replacement, Vail Resort offices and elevator
equipment room.
Elevator and HVAC vendors will need to be contracted by VR for FA system control
upgrades. FA HVAC and Elevator controls connections and testing will need to be
coordinated with the project contractors through SG project management.
VR is positioned to handle the third owners' portion of the retail spaces, Burton and the
Travel Agency, for the system upgrade. Project impedance from the third owner will
need to be reviewed and coordinated in a timely fashion with the contractors. If wiring
and/or FA panel parts for Burton and the Travel Agency's conventional devices are
needed, it will be handled as a change arder.
For the HOA portion SG will provide parts and smarts to Thul Electronics. Thul will be
the prime contractor to the HOA and will handle all residential units and residential
common areas, including elevator lobbies and the elevator shaft.
Vail Resorts will pull the permit and pay the fee.
A proposed schedule follows:
3/29 Pricing submitted by all contractors
4/4 Approval from HOA/Board/Vail Resorts; Permit submittal to Vail Fire
4/22 Start date (pending approval from the unit's owners)
4/22 parts delivered and panel change out with flow and tampers supervision
5/20 testing for owner and AHJ final
5/24 is a target coinpletion date (5/20 and 5/24 target dates are subject to approval from
the unit's owners and project contractars).
DWG files are not available far this site, permit, scope of work, a FA riser and FA device
submittals may be required by the local AHJ. SLS is coordinating this portion with the
owners.
The existing system will be removed and replaced with the emphasis of the sprinkler flow
and tampers to be supervised immediately. Monitoring will need to be completed with
the VR Central Station.
The inclusion/exclusion section below is for the VR portion of the project:
Included in Scope of Work:
1. Fire alarm equipment
2. Programming/archiving of system files
3. Verification of fire alarm monitoring
4. Pre-Testing AHJ final and acceptance with Record of Completion
5. Project management/Coordination
6. Installation, labor, and materials
7. Wire
Excluded from Scope of Work:
1. 120v-ac electric 20amp breaker
2. Electrical conduit
3. Cutting, Painting and patching
4. Temporary protection or fire watches
5. Hard-wiring for AHU shutdown
6. Drawings, engineering, and CADD
7. Complete system design per code
8. New Fire Alarm Wiring
The inclusion/exclusion section below is for the Thu] portion of the project:
Included in Scope of Work:
1. Fire alarm equipment
2. Programming/archiving of system files
3. Verification of fire alarm monitoring
4. Pre-Testing with AHJ final testing with Record of Completion
5. Project management/Coordination
Excluded from Scope of Work:
1. 120v-ac electric 20amp breaker
2. Electrical conduit
3. Installation, labor, and materials
4. Cutting, Painting and patching
5. Temporary protection or fire watches
6. Drawings, engineering, and CADD
7. Complete system design per code
8. New Fire Alarm Wiring
Devices shall only be installed upon completion of all painting and finish work, and
installation of ceiling tiles (if applicable). Devices installed before final cleaning of the
jobsite may require additional labor for cleaning which is not covered by this quote.
Any device that has paint on it may need to be replaced at the gene�al contractors or
property owner's expense.
Please note that fire alarm devices required by the AHJ, Owner, Owners Insurance
Company or Owners Representative, above and beyond the scope of work, will require a
change order.
Thank you far the opportunity to provide you with this quotation.
Please feel free to contact me at anytime with additional questions or concerns.
Glen Williamson � ESSR
SimplexGrinnell, Tyco Integrated Security
910 Nottingham Rd Ste 3
Avon, CO. 81620
Avon Tel: 970-688-5645
Mobile: 970-556-7796
Denver Tel: 303-355-0500
Fax: 303-355-0615
Toll Free: 800-877-0472
qwilliamson c(D.simplexqrinnell.com
www.simplexgrinnel I.com
� �� 6240 Smith Rd
� � DENVER, CO 80216-4632
(303) 355 0500
,�'�/1']#j��Jl([�'JJl1►►]l.°�i� FAX: (303) 355 0615
www.simplexgrinnell.com
SimplexGrinnell Quotation
TO:
Vail Mountain Security Project: One Vail Place-VR
P.O. BOX 7-V10 Customer Reference:
VAIL, CO 81658-7000 SimplexGrinnell Reference: 968455802
Date: 04/10/2013
Page 1 of 9
SimplexGrinnell is pleased to offer for your consideration this quotation for the above project.
QUANTITY MODEL NUMBER DESCRIPTION
1 Vail Place Vail Resorts
Vail Resorts Material List
45 4098-9714 PHOTO SENSOR
6 4098-9733 HEAT SENSOR
51 4098-9792 SENSOR BASE
7 4099-9003 MANUAL STATION - DOUBLE ACTION
1 4906-9130 HORN/STROBE MC WHITE CEILING
28 4906-9129 HORN/STROBE MC WHITE
8 4906-9103 STROBE MC WHITE
6 4906-9104 STROBE MC WHITE CEILING
2 4098-9756 DUCT SENSOR HOUSING-4-WIRE
2 4098-9857 SAMPLING TUBE 73", PLASTIC
2 2098-9806 REMOTE TEST STATION
9 4090-9001 SUPERVISED IAM
5 4090-9002 RELAY IAM
2 2081-9276 BATTERY 33AH
1 ETHEDROP ETHERNET-NETWORK COMPATIBLE
1 4906-9131 WP MC AV NON-ADDR WALL MT RED
1 4905-9828 WP AV/VO 1.51N BACK BOX RED
Vail Resorts Install
DPINSTAL VR Installation - Encore
1 VP VR FACP 4010ES
1 4010-9401 4010ES FACP 120V RED
1 4010-9816 DACT (POINT REPORTING)
2 2081-9276 BATTERY 33AH
1 4009-9201 NAC EXTENDER 120VAC, IDNET
2 2081-9275 BATTERY 18AH
One Vail Place VR SG Labor
Professional Services- One Vail Place VR SG Labor
PM LAB PROJECT/CONSTRUCTION MGMT
PREP LAB PRE-SITE PREPARATION LABOR
THIS QUOTATION AND ANY RESULTING CONTRACT SHALL BE SUBJECT TO THE GENERAL TERMS AND CONDITIONS ATTACHED HERETO.
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America
� �� Project: One Vail Place-VR
� Customer Reference:
SimplexGrinnell Reference: 968455802
..ri1117�3��'X�71!!1l1+��f Date: 04/10/2013
Page 2 of 9
SimplexGrinnell Quotation
QUANTITY MODEL NUMBER DESCRIPTION
Technical Services- One Vail Place VR SG Labor
COMM LAB Commissioning Labor
Permit and fee
Permit and fee
DPSVC Permit fee for 1 Vail Place
Total net selling price, FOB shipping point, $36,440.33
Com ments
The following scope of work encompasses each proposal for the One Vail Place building:
Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(cr�COMCAST.NET <mailto:SHANERLS(a�COMCAST.NET>
WWW.SHANERLIFESAFETY.COM <http://WWW.SHANERLIFESAFETY.COM>
Encore Electric contact is RJ Vik
R. J. Vik
Encore Electric, Inc.
9�0�--4�1�--oso�-o�en
970)--949)--927)-7 office
970)--949)--928)-0 fax
rj.vik�,EncoreElectric.com<mailto:rj.vik a�EncoreElectric.com>
Thul Electronics contact is Ron Davidson
970 949 4638
i-on��thulelectronics.con� <lnailto:ron(u�thulelectronics.coin>
Vail Resort Project contact is Bob Norris
Robert C. Norris
Manager-Vail Mountain Security
970-754-3055
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America
� �� 6240 Smith Rd
� � DENVER, CO 80216-4632
(303) 355 0500
,�'�/1']#j��Jl([�'JJl1►►]l.°�i� FAX: (303) 355 0615
www.simplexgrinnell.com
SimplexGrinnell Quotation
TO:
Vail Mountain Security Project: Garage Equipment
P.O. BOX 7-V10 Customer Reference:
VAIL, CO 81658-7000 SimplexGrinnell Reference: 970197107
Date: 04/12/2013
Page 1 of 8
SimplexGrinnell is pleased to offer for your consideration this quotation for the above project.
QUANTITY MODEL NUMBER DESCRIPTION
Garage Equipment
Garage Equipment
1 4099-9003 MANUAL STATION - DOUBLE ACTION
2 4906-9129 HORN/STROBE MC WHITE
4 4098-9792 SENSOR BASE
3 4098-9733 HEAT SENSOR
1 4098-9714 PHOTO SENSOR
Garage Install
DPINSTAL Installation - Encore
Professional Services - Garage Equipment
PM LAB PROJECT/CONSTRUCTION MGMT
Technical Services - Garage Equipment
COMM LAB Commissioning Labor
Total net selling price, FOB shipping point, $3,874.33
Com ments
The following scope of work encompasses each proposal for the One Vail Place building:
Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(�a,COMCAST.NET <mailto:SHANERLS(cr�,COMCAST.NET>
WWW.SHANERLIFESAFETY.COM <htt�://WWW.SHANERLIFESAFETY.COM>
THIS QUOTATION AND ANY RESULTING CONTRACT SHALL BE SUBJECT TO THE GENERAL TERMS AND CONDITIONS ATTACHED HERETO.
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America
� �� 6240 Smith Rd
� � DENVER, CO 80216-4632
(303) 355 0500
,�'�/1']#j��Jl([�'JJl1►►]l.°�i� FAX: (303) 355 0615
www.simplexgrinnell.com
SimplexGrinnell Quotation
TO:
Vail Mountain Security Project: Elevator RM Equipment
P.O. BOX 7-V10 Customer Reference:
VAIL, CO 81658-7000 SimplexGrinnell Reference: 970197208
Date: 04/12/2013
Page 1 of 8
SimplexGrinnell is pleased to offer for your consideration this quotation for the above project.
QUANTITY MODEL NUMBER DESCRIPTION
Elevator RM Equipment
Elevator RM Equipment
4 4090-9002 RELAY IAM
1 4090-9001 SUPERVISED IAM
2 2088-9021 ENCAPSULATED RELAY PAM-1
3 4098-9792 SENSOR BASE
2 4098-9733 HEAT SENSOR
1 4098-9714 PHOTO SENSOR
Elevator Install - Encore
DPINSTAL Elevator Install - Encore
Professional Services- Elevator RM Equipment
PM LAB PROJECT/CONSTRUCTION MGMT
Technical Services- Elevator RM Equipment
COMM LAB Commissioning Labor
Total net selling price, FOB shipping point, $6,869.12
Com ments
The following scope of work encompasses each proposal far the One Vail Place building:
Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(�a,COMCAST.NET <mailto:SHANERLS(a�COMCAST.NET>
WWW.SHANERLIFESAFETY.COM <http://WWW.SHANERLIFESAFETY.COM>
THIS QUOTATION AND ANY RESULTING CONTRACT SHALL BE SUBJECT TO THE GENERAL TERMS AND CONDITIONS ATTACHED HERETO.
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America
� �� 6240 Smith Rd
� � DENVER, CO 80216-4632
(303) 355 0500
,�'�/1']#j��Jl([�'JJl1►►]l.°�i� FAX: (303) 355 0615
www.simplexgrinnell.com
SimplexGrinnell Quotation
TO:
Vail Mountain Security Project: Burtons
P.O. BOX 7-V10 Customer Reference:
VAIL, CO 81658-7000 SimplexGrinnell Reference: 970030205
Date: 04/02/2013
Page 1 of 8
SimplexGrinnell is pleased to offer for your consideration this quotation for the above project.
QUANTITY MODEL NUMBER DESCRIPTION
1 Vail Place - Burtons
Burtons Material List
5 4098-9792 SENSOR BASE
5 4098-9714 PHOTO SENSOR
3 4099-9003 MANUAL STATION - DOUBLE ACTION
3 4906-9127 HORN/STROBE MC RED
Burtons Install - Encore
DPINSTAL Burtons Install - Encore
Burton -SG Labor
Professional Services - Burton - SG Labor
PM LAB PROJECT/CONSTRUCTION MGMT
Technical Services - Burton - SG Labor
COMM LAB Commissioning Labor
Total net selling price, FOB shipping point, $2,977.02
Com ments
The following scope of work encompasses each proposal for the One Vail Place building:
Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(�a,COMCAST.NET <nlailto:SHANERLS(a�COMCAST.NET>
WWW.SHANERLIFESAFETY.COM <http://WWW.SHANERLIFESAFETY.COM>
THIS QUOTATION AND ANY RESULTING CONTRACT SHALL BE SUBJECT TO THE GENERAL TERMS AND CONDITIONS ATTACHED HERETO.
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America
� �� 6240 Smith Rd
� � DENVER, CO 80216-4632
(303) 355 0500
,�'�/1']#j��Jl([�'JJl1►►]l.°�i� FAX: (303) 355 0615
www.simplexgrinnell.com
SimplexGrinnell Quotation
TO:
Vail Mountain Security Project: 1 Vail Place -Travel Agency
P.O. BOX 7-V10 Customer Reference:
VAIL, CO 81658-7000 SimplexGrinnell Reference: 970030104
Date: 04/02/2013
Page 1 of 8
SimplexGrinnell is pleased to offer for your consideration this quotation for the above project.
QUANTITY MODEL NUMBER DESCRIPTION
1 Vail Place-Travel Agency
Travel Agency Material List
2 4098-9792 SENSOR BASE
2 4098-9714 PHOTO SENSOR
1 4906-9127 HORN/STROBE MC RED
1 4099-9003 MANUAL STATION - DOUBLE ACTION
Travel Agency Install
DPINSTAL Travel Agency Install - Encore
Travel Agency- SG Labor
Professional Services -Travel Agency- SG Labor
PM LAB PROJECT/CONSTRUCTION MGMT
Technical Services -Travel Agency- SG Labor
COMM LAB Commissioning Labor
Total net selling price, FOB shipping point, $1,301.48
Com ments
The following scope of work encompasses each proposal for the One Vail Place building:
Contacts:
Deborah L. Shaner, P.E.
Fire Protection Engineer
Shaner Life Safety
(970) 409-9082
SHANERLS(a�COMCASTNET <mailto:SHANERLS(a�COMCAST.NET>
WWW.SHANERLIFESAFETY.COM <http://WWW.SHANERLIFESAFETY.COM>
THIS QUOTATION AND ANY RESULTING CONTRACT SHALL BE SUBJECT TO THE GENERAL TERMS AND CONDITIONS ATTACHED HERETO.
Fire, Security, Communications, Sales & Service
Offices & Representatives in Principal Cities throughout North America