NEW EXTERIOR 2X6
' AT I'-4" STUD WALL
WITH 7/I6" PLYWOOD
SHEATHING AT EXTERIOR
AND 5/8" GYP. SHEATHING
AT INTERIOR
NEW 3/4" OR 5/8"
PLYWOOD FLOOR
SHEATHING- NAIL
AND GLUE TO EXISTING
DEG�GING- INSTALL
LEVEL WITH EXISTING
INTERIOR FLOOR
SHEATHING
�
I��
rr
/ �
� '
J
EXISTING DEG�ING
Monroe & Newell
Engineers,Inc.
P.O.Box 1597
70 Benchmark Road,Suite 204
Avon,Colorado 81620
(970)949-7768
FAX(970)949-4054
FMAii.avon@monroe-newcll.com
� � � � � �I Y
I I/�" = I'-O"
SUN VAIL UNIT 21A
605 NORTH FRONTAGR ROAD VVEST
VAII„COLORADO
NO.#9163
� I
NEW (3)-5 I/�" LVL
FLOOR BEAM IN WALL
NAIL NEW WALL
SHEATHINC� TO RIM
JOIST WITH 8d X I I/�"
NAILS AT 6"
EXISTINC� FLOOR—
AND DEG� FRAMING
OF UNIT ABO�/E
NEW HSS 4X4X3/8 BEAM
W I TH 2X6 TOP PLATE
WITH I/�" m THREADED
RODS AT 2'-O"- WELD
TO BEAM
3/I6
NEW I/4" X 4" X 5" STEEL
PLATE WITH 1/�" � X 3"
LAG-BOLT
ry
N
�
I
�
I
SECTION AT
BEAM END
� � � �
i v�" = i�-o.,
NEW DEG� SHEATHING
AND WATERPROOFING
NEW (3)2X6
GOLUMN
�I � ��
TITLE: DETAII.S
DATE:4-]0-2013
SCALE:1/4"=1'-0"
':j€ _, '�;
fi�'VIEV1l��
':��/I P� _
�te:� _ �����3
;;' `�
t z�-
DRAWN BY:AVN
S3
�
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. EXTERIOR DECK
B. TYPICAL FLOOR
C. ROOF <4:12 SLOPE
D. WIND
3 SECOND GUST
FASTEST MILE
EXPOSURE
100 PSF
40 PSF
100 PSF
90 MPH
85 MPH
B
E. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
F. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2012 EDITION.
2. TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. STEEL CONSTRUCTION
a. ALL WELDING SHALL RECEIVE [ONTINUOUS SPECIAL INSPECTION
EXCEPT THE FOLLOWING:
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
ACCORDANCE WITH SECTION 1704.3.
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE
MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
WELDING.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING S/16" IN SIZE.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
e. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGH
STRENGTH BOLTS.
3. STRUCTURAL STEEL
1
�A`
rr
� �
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT TUBE MEMBEERS
WHICH SHALL CONFORT TO ASTM A500, GRADE B, LATEST EDITIONS. STEEL SUPPLIER
MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1.
E. MINIMUM WELDS TO BE PER AISC TABLE ]2.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNlE55 NOTED OTHERWISE.
Monroe & Newell
Engineers,Inc.
P.O.Box 1597
70 Benchmark Road,Suite 204
Avon,Colorado 81620
(970)949-7768
FAX(970)949-4054
F.MATi.avon@monTOe-newelLcom
SUN VAIL LTNIT 21A
605 NORTH FRONTAGR ROAD WEST
VAII.,COLORADO
!`.[i1�iZF1c3
4. WOOD
A. ALL FRAMING LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSZ
2" TO 4" THICK - 6" AND WIDER N0. 2 Fb = 900 PSI
5" THICK - 5" AND WIDER N0. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETINE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
C. TREATED SILL PLATE LUMBER MAY BE HEM-FIR, STRUCTURAL #1 GRADE.
D. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304-9.1 UNLESS NOTED OTHERWISE.
E. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIUNS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SNALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALON6 PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d NAILS AT 6" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOOR SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END 70INT5 STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
5. NON-STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED �NLESS NOTED OTHERWISE.
6. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. WATERPROOFING, VAPOR BARRIERS, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
C. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS.
D. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.
.`.\%i�V�°Ci�
�MPLI,�:�`,:''� •
���, -/�-
�t2:__r._____`7
'tA �. ��
,�� l
�
TITLE: GENERAL NOTES
DATE:4-10-2013
SCALE:1/4"=1'-0" � DRAWN BY:AVN
S4
�