HomeMy WebLinkAboutB13-0128 Plans approvedGENERAL NOTES: PITKIN CREEK CONDO, BLDG. 3, 6, & 7 STAIR REPAIR JOB# 0304 -13 DESIGN CRITERIA: STAIRS LIVE LOAD 100 PSF STAIRS DEAD LOAD 10 PSF GUARDRAILS (PER SEC. 1607.8 2012 IBC) 50 PLF IBC EDITION: 2012 STRUCTURAL WOOD FRAMING: 1. EXCEPT WHERE NOTED OTHERWISE, ALL 2" NOMINAL LUMBER EXCEPT STUDS SHALL BE DOUGLAS FIR -LARCH #2 AND BETTER. ALL SOLID TIMBER POSTS AND BEAMS 3" NOMINAL AND WIDER SHALL BE DOUGLAS FIR -LARCH #2 UNLESS NOTED OTHERWISE ON PLAN. 2. BOLTS USED IN FRAMING CONNECTIONS SHALL BE INSTALLED WITH STANDARD WASHERS AND NUTS. 3. REFER TO THE 20121 R 2012 IBC TABLE 2304.9.1 FOR MINIMUM FASTENING SCHEDULE. A COPY OF THIS TABLE CAN BE PROVIDED UPON REQUEST. AS STATED IN SECTION 2304.9.5 OF THE 2012 IBC SECTION 2304.9.5: FASTENERS IN CONTACT WITH PRESERVATIVE - TREATED AND FIRE - RETARDANT - TREATED WOOD SHALL BE OF HOT - DIPPED ZINC - COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENINGS FOR WOOD FOUNDATIONS SHALL BE AS REQUIRED IN AF &PA PWF. 4. UNLESS NOTED OTHERWISE, STEEL CONNECTORS SHALL BE USED TO JOIN RAFTERS, JOISTS AND BEAMS SUCH AS SIMPSON STRONG -TIE CONNECTORS OR EQUIVALENT. CONNETORS THAT ARE USED IN EXTERIOR APPLICATIONS AND IN CONTACT WITH PRESERVATIVE - TREATED WOOD SHALL HAVE COATING TYPES AND WEIGHTS IN ACCORDANCE WITH THE TREATED WOOD OF CONNECTOR MANUFACTURERS' RECOMMENDATIONS OR IN ACCORDANCE TO IBC SECTION 2304.9.5.1. STRUCTURAL STEEL: 1. ALL BOLTS USED IN STEEL FRAMING SHALL CONFORM TO ASTM SPECIFICATION A325. ANCHOR BOLTS AND BOLTS (INCLUDING LAGS) USED IN TIMBER CONNECTIONS MAY BE ASTM A307. GENERAL REQUIREMENTS: 1. CHECK ALL DIMENSIONS AGAINST ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. CONTACT ENGINEER IF DISCREPANCIES IN DIMENSIONS ARE DISCOVERED. 2. THE STRUCTURAL DRAWINGS DESCRIBE THE COMPLETED STRUCTURE. THESE DRAWINGS HAVE BEEN PREPARED FOR THE USE OF A QUALIFIED CONTRACTOR WITH EXPERIENCE IN THE CONSTRUCTION SYSTEMS AND TECHNIQUES DESCRIBED. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING IN THE PROPER SEQUENCE, AS MAY BE REQUIRED TO ACHIEVE THE FINAL COMPLETED STRUCTURE. THE SEQUENCE OF CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIONS (NOT IN CONTRACT). 3. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS, METHODS SEQUENCES AND PROCEDURES FOR CONSTRUCTION OF THIS PROJECT. NOTIFY STRUCTURAL ENGINEER OF ERRORS OR OMISSIONS IN THE CONSTRUCTION DOCUMENTS IMMEDIATELY. DO NOT PROCEED UNTIL ERRORS OR OMISSIONS ARE RESOLVED. COORDINATE REQUIREMENTS FOR ALL PENETRATIONS THROUGH STRUCTURAL MEMBERS WITH STRUCTURAL ENGINEER. JOBSITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. OBSERVATION VISITS BY THE STRUCTURAL ENGINEER ARE FOR DETERMINATION OF GENERAL COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. THIS OBSERVATION VISIT IS NOT AN INSPECTION. THE CONTRACTOR SHALL CONTACT THE ENGINEER AT THE APPROPRIATE TIME TO SCHEDULE THIS VISIT. 5. IF NEW CONSTRUCTION ADJOINS AN EXISTING STRUCTURE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS, ELEVATIONS AND ALL EXISTING CONDITIONS. UNDERPINNING AND SHORING OF EXISTING STRUCTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONSULT WITH THE ENGINEER FOR SHORING DESIGN AND RECOMMENDATIONS (NOT IN CONTRACT). 6. WHILE EVERY EFFORT IS MADE TO PROVIDE A COMPLETE AND ACCURATE SET OF CONSTRUCTION DOCUMENTS, ERRORS OR OMISSIONS MAY OCCUR. RELEASE OF THESE DRAWINGS ANTICIPATES CONTINUED COOPERATION AND COMMUNICATION BETWEEN THE CONTRACTOR, ARCHITECT AND ENGINEER TO PROVIDE THE BEST POSSIBLE STRUCTURE. 2012 IBC requirements Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TOWN OF VAf1 By J Mondragon at 2:11 pm, May 06, 2013 Design Review Staff Approval TOWN OF VAI L � By Joe Batcheller at 9:43 am, May 16, 2013 INDICATES NEW REMOVE EXISTING STAIRS HAND RAIL & REPLACE WITH NEW STAIRS IN SAME LOCATION INDICATES NEW 4x4 NEWEL POST, z TYP. L ----- 1 ---------- 7/ (N) - 4 x 12 (STRINGER) N - 1 - 2 x 12 (STRINGER)_ o (N) - 4 x 12 (STRINGER) 3' -9" (MAX. SPACING) 2 KS12 15' -8" MAX. RUN ABBREVIATIONS LIST ABV. ABOVE ADJ. ADJACENT BLKG. BLOCKING BM. BEAM BRG. BEARING CANT. CANTILEVER CLR. CLEAR CONT. CONTINUOUS (E)- EXISTING EA. EACH EQ. EQUAL HORIZ. HORIZONTAL INFO. INFORMATION JSTS. JOISTS O.C. ON CENTER (N)- NEW fl' PLATE REF. REFERENCE SCHED. SCHEDULE T TRIMMER T.B. THROUGH BOLT TO TOP OF TRTD. TREATED TYP. TYPICAL VERT. VERTICAL VIF VERIFY IN FIELD W.P. WATERPROOF W/ WITH VERIFY EXISTING STEEL ANGLE CONN. W/ ENG. PRIOR TO CONSTRUCTION EXISTING LANDING W/ (E)- STL. C- CHANNELS ALONG PERIMTER & MID -SPAN EXISTING BUILDING, TYP. STAIR & RAILING FRAMING PLAN SCALE: 1/4" = 1' -0 PLAN NOTES: 1. NEW NEWEL POSTS NOT CONTINUOUS BELOW ARE INDICATED: ❑ 2. (E)- EXISTING FRAMING INDICATED AS THUS: (- — — -) (N) -NEW FRAMING INDICATED AS THUS: 3. DO NOT SCALE DRAWINGS A� N PLAN Received TOWN O F VA 11 ° By Lynne Campbell at 5:59 pm, Apr 29, REG1 vo oti C)M �CNO N Il- M X o0 mV v v 0? rn o0 0 rnrn aQ < C 0 Y c - I rA 07 O O z C'6 O Q_j 0 Q Q Y C LU > LU Ir H LU O U C) m C/) O PROJECT: 0304 -13 DRAWN BY: JPL REVIEWED BY: JPL D A T E: PERMIT 04.24.13 REVISIONS: GENERAL NOTES, STAIR & RAILING FRAMING PLAN S1 131 ... 1 N a 1a (N) -2x6 CAP (N) -(2)- #10x2 1/2" DECK SCREWS, TOP & BOT. TYP. INDICATES NEWEL — POST BEYOND (N) -2x2 PICKETS @ 5" O.C. W/ MAX. OPENING OF 4" (N) -4x4 NEWEL POST - @ 3' -9" O.C. (MAX. SPACING) NOTCHED 1 1/2" @ TOP & BOT., TYP. @ STAIR STRINGS (N)-(2)-1/2" O T.B.'s, W/ 2" OUTSIDE DIAMETER FENDER WASHER TYP. @ 44 NEWEL POSTS. N211 (N)- (1) - #10 x 2 1/2" DECK SCREWS INTO TOP OF 2x6 CAP @ 12" O.C. & (2) -INTO EA. 44 NEWEL POST (N) -2x4 TOP RAIL SET INTO NOTCHED 12 NEWEL POSTS W/ (2)- #10x3" SCREWS, TYP. @ STAIR } STRINGERS ~ Z (N) -4x12 STAIR o STRINGER C, TREADS (N)- SIMPSON TA9Z STAIRCASE ANGLE EA. SIDE OF TREADS SCALE: 3/4" = V -0 Shand rail required. Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TOWN OF VA L By J Mondragon at 2:11 pm, May 06, 2013 guard rail height 42 New railings are to match the color and inches minimum architectural style of the existing railings prior to requesting a final planning inspection. Design Review 01! Staff Approval TOWN ! By Joe Batcheller at 9:44 am, May 16, 2013 walking surface to be a minimum 36 inches wide (N) -2x6 CAP (N) -(2)- #10x2 1/2" DECK – SCREWS, TOP & BOT. TYP. (N) -2x2 PICKETS @ 5" O.C. W/ MAX. OPENING OF 4" INDICATES NEWEL – POST BEYOND (N) -44 NEWEL POST, NOTCHED 1 1/2" @ BOT.TYP. (N)- (2) -1/2" a T.B.'s, W/ 2" OUTSIDE DIAMETER FENDER WASHER TYP. @ 4x4 NEWEL POSTS. (PACK WEB SOLID) (N)- (1) - #10 x 2 112" DECK SCREWS INTO TOP OF 2x6 CAP @ 12" O.C. & (2) -INTO EA. 4x4 NEWEL POST (N) -2x4 TOP & BOT. RAIL W/ (2) - #12 x3 1/2" TOE - SCREWS z 0 (E)- DECKING (E) -7" DEEP STL. C- CHANNEL SCALE: 3/4" = V -0 Received 1 TOWN OF ffl By Lynne Campbell at 6:00 pm, Apr 29, 2013 ryU REGQ�o sSiOHn�� "I O O tl- 0) N O t­ ,'t Co M N r ti M X rn 0) CO m U rn rn o 0 o z M rn �> a< C 0 Y cD z LU w z 0 z M 0 0 0 0 Q U Q Q �C,5W> LU � cc LL LU p� 0 U 0 Q z m 0 PROJ ECT: 0304 -13 DRAWN BY: JPL REVIEWED BY: JPL D A T E : PERMIT 04.24.13 REVISIONS: DETAILS S2