F13-0017 APPLICATION AND CUT SHEETS.pdf
Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970-479-2128,". Fax: 970-479-2452 Web: www.vailgov.com Development Review Coordinatot FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: 380 E. Lionshead Circle Unit#5 Project#: (Number) (Street) (Suite#) g Building/Complex Name: Lodge at Lionshead Building Permit#: Sprinkler Permit#: Contractor Information: Lot#: Block# Subdivision: Company: Western States Fire Protection Company Address: 7026 S. Tucson Way Detailed Description of Work: Install piping for future City: Centennial State: CO Zip:80112 tie-in. 16 sprinkler heads. Contact Name: Jason Brochu Contact Phone: 303-928-0192 (use additional sheet if necessary) E-Mail jason.brochu @wsfp.us Detailed Location of Work: Town of Vail Contractor Registration No.: 338-S X /y Does a Monitored Fire Alarm Exist? Yes(v) No( ) Corrfractor Signature(required) Does a Sprinkler System Exist? Yes( ) No(v) Property Information Work Class: Parcel#: 2101-064-06-032 (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or New( ) Addition( ) Remodel ( ) Repair( ) visit www.eaglecounty.us/patie) Retro-Fit(v) Other( ) Tenant Name: GABILU INC Type of Building: Owner Name: GABILU INC Single-Family( ) Duplex( ) Multi-Family(v) Commercial ( ) Restaurant( ) Other( ) Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler$: 8050.00 Date Received: 01-Feb-10 Job Number.051921 Hydraulic Overview Report Description:Residential Job Jw Aun. ,. Design C61921 J[Qrem,: Ptrom rnx LODGE AT LIONSHEAD#5 Address, slime c.dmc+eJwm.weme ewmw 380 E LIONSHEAD CIRCLE Adhess3 AHJ VAIL,CO 81657 System 1 Aree m AOpkepan 0.100gpMM2 900k1(Actual 410 ft") M*M 06.0nd-9 s>:.vsae 0.0, Hww sham 4.9 K-Factor 25.64 at 27.295 100.00 caa.oe Pa sv.aw Hwbw Of gprwkbs CMpp W 14dttz 4 System pressure Demand %T n_Demme 88.850 115.34 1a oemerw Presare Resiw 215.34 @ 88.854 +46,813(34.5%) Supplies Check Point Gauges Node Name Flow(aom) HoseFlow(nom) Static(psi) Resdual(esi) Identifier Pressure(psi) K-Factor(K) Flow(nom) 1 Water Supply 933.10 100.00 140.000 74.648 Thomas M.Coakley,GET Western States Fire Protection Co. N10ET Level III Registration#107852 Sprinkler System Layout Signa CS1921 Lodge Lionshead#5-cad Water Supply at Node 1 (933.10,100.00,140.000,74.648) 150-- 1 Static Pressure 140.000 135 120 105 115.34 @ M850 Q • • ------------ �' 75 f 33.10 14.548 y ....• W a(D T 80 System demand curve 45 30 15 0 Rq�y 2%V%00 800 1000 1200 1400 1600 1800 2000 Water flow,gpm �k,0 M.E.P.CAD,Inc. AutoSPRINK@ VR10 v10.0.55.0 5!712013 3:33:57PM Page 1 Hydraulic Graph Job Number:CS1921 Report Description:Residential Water Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 115.34 @ 88.850 i i 215.34 with hose streams Z Q 75 \933 933.10 @ 74.648 a o_ 60 S stem demand curve 45 30 15 0 0200 400 600 800 1000 1200 1400 1600 1800 2000 Water flow,gpm Hydraulic Graph Water Supply at Node 1 Static:Pressure 140.000 Residual:Pressure 74.648 @ 933.10 Available Pressure at Tme of Test 135.663 @ 215.34 System Demand 88.850 @ 115.34 System Demand(Including Hose Allowance at Source) 88.850 @ 215.34 k,,©M.E.P.CAD,Inc. tljjj AutoSPRINK®VR10 v10.0.55.0 5/7/2013 3:34:16PM Page 2 4111 1 Summary Of Outflowing Devices Job Number:CS1921 Report Description:Residential Actual Flow Minimum Flow K-Factor Pressure Device m m K (psi) Sprinkler 109 29.63 25.60 4.9 36.560 Sprinkler 110 33.99 25.60 4.9 48.110 Sprinkler 111 26.12 25.60 4.9 28.421 b Sprinkler 114 25.60 25.60 4.9 27.295 b Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. AutoSPRINKO VR10 00.0.55.0 5/7/2013 3:34:31 PM Page 1 I lHydraulic Analysis Job Number:CS1921 Report Description:Residential Pipe Ty e Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length • •Route 1 BL 1.05 25.60 9.40 150 0.132243 8'-6" Pf 1.126 114 10'-0" 25.60 4.9 27.295 Sprinkler Pe 111 10'-0" 28.421 8'-6" Pv BL 1.05 51.72 18.98 150 0.485778 12'-9" Pf 8.139 111 10'4" 26.12 4.9 28.421 Sprinkler 4'-0" Pe 109 10'4" 36.560 2E(2'-0") 16'-9" Pv BL 1.05 81.35 29.86 150 1.122778 10'-2'/z" Pf 13.687 109 10'4" 29.63 4.9 36.560 Sprinkler 2'-0" Pe 12 10'4" 50.247 T(2'-0") 12'-2'/2' Pv FM 1.53 81.35 14.25 150 0.185454 V-10" Pf 0.988 12 10'4" 50.247 3'-6" Pe 11 10'-0" 51.234 T(3'-6") 5'-4" Pv FM 1.53 115.34 20.21 150 0.353766 2'-7'/i' Pf 0.931 11 10'4" 51.234 Pe 3 10'4" 52.165 2'-7/2' Pv ST 2.07 115.34 11.03 120 0.122345 38'-0" Pf 7.096 3 10'-0" 52.165 E(5'-0") 20'-0" Pe 8.671 4 -10'-0" 67.932 3E(5'-0") 58'-0" Pv ST 4.03 115.34 2.91 120 0.004759 11'-3'/z" Pf 20.488 4 -10'-0" 67.932 10'-0" Pe 19 -10'-0" 88.420 E(10'-0"),BFP(-12.387), 21'-3'/i' Pv PRV-8.000 ST 4.28 115.34 2.57 140 0.002657 144'-0" Pf 0.430 19 -10'-0" 88.420 17'-11" Pe 1 -10'-0" 88.850 E(17'-11"),S 161'-11" Pv 100.00 Hose Allowance At Source 1 215.34 fi&•••••Route 2••••• BL 1.05 33.99 12.47 150 0.223387 10'-3'/z' Pf 2.749 110 10'4" 33.99 4.9 48.110 Sprinkler 2'-0" Pe 8 10'4" 50.859 T(2'-0") 12'-3/2' Pv FM 1.53 33.99 5.95 150 0.036898 6'-8" Pf 0.375 8 10'4" 50.859 3'-6" Pe 11 10'4" 51.234 T(3'-6") 1 10'-2" Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. 411 AutoSPRINK®VR10 00.0.55.0 5/7/2013 3:34:38PM Page 2 I N I Hydraulic Analysis Job Number:CS1921 Report Description:Residential Pipe Ty e Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow Eel 111/4°Elbow Eel 221/ Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. 3 AutoSPRINK®VR10 vl0.0.55.0 5/7/2013 3:34:38PM Page 3 Western States Fire Protection Co. P!q- z d"'d Fire Sprinkler System Material Data Sheets For Lodge at Lionshead Unit #5 380 E. Lionshead Circle Unit #5 Vail, CO 81657 Prepared by: Jason Brochu Designer Western States Fire Protection Co. 274 Center Dr Glenwood Springs, CO 81601 Cell: (303)928-0192 Office: (970)618-3294 Fax: (303)970-9504 Email:jason.brochu @wsfp.us WSFP#CS 1921 May 7,2013 Bulletin 176 Rev.A W 1. R Model F1 bila Residential Sprinklers for Design Density of .10 gpm/ft2 D Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpni ftz Types: 1. F1 Res 49 Pendent '' F 2. F1 Res 49 Recessed Pendent/F 1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res 49 CCP Pendent _ 5. F1 Res 58 Pendent F1 Res 49,58&76 F1 Res 49,58&76 6. F1 Res 58 Recessed Pendent/F1 Recessed Pendent F1 Recessed Pendent/FP 7. F1 Res 58 Recessed Pendent/FP 8. F1 Res 58 CCP Pendent 9. F1 Res 44 & 58 HSW 10. F1 Res 44 & 58 HSW Recessed HSW/F2 11. F1 Res 44 SWC 12. F1 Res 76 Pendent ;' 13. F1 Res 76 Recessed Pendent/F 1 14. F1 Res 76 Recessed Pendent/FP 15. F1 Res 76 CCP Pendent F1 Res 49, 58&76 F1 Res 44&58 CCP Pendent Recessed HSW/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler ;' UL Guide Number VKKW F1 Res 44 SWC Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Product Description Technical Data: Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) • Thermal Sensor: Nominal 3mm glass-bulb combine excellent durability, high sensitivity glass-bulb • Sprinkler Frame : Brass Casting and low profile decorative design. • Sprinklers' Pressure Rating : 175 psi The 3mm glass-bulb pendent sprinklers permit the Factory Hydrostatically Tested to 500 psi efficient use of residential water supplies for sprinkler . Thread Size: 112" NPT(R1/2) coverage in residential fire protection design. • K-Factor.4.9(Actual)-F1 Res 49 Pendent Sprinkler The low flow F1 Res sprinklers are specially 5.8(dial)-F1 Res 58 Pendent&HSWSprinkler engineered for fast thermal response to meet the 7.6(Actual)-F1 Res 76 Pendent Sprinkler sensitive fire protection application needs of the latest 4.4(Actual)-F1 Res 44 HSW Sprinkler residential market standards (UL 1626 Standard *). • Density: Minimum 0.10 gpm/ft2 Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. * Effective date 7/12/02 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Example No. 1 Protection according to UL 1626 Standard*. Be sure Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) that orifice size, temperature rating, deflector style and Coverage Area= 12 x 20 = 240 ft2(22.3 m2) sprinkler type are in accordance with the latest Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm published standards of The National Fire Protection Using an F1 Res 49 Pendent Sprinkler, K=4.9 Association or the approving authority having Pressure= (24/4.9)2 = 24 psi (1.65 bar) jurisdiction. The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) When using F1 Residential Sprinklers for systems coverye area using the baseline density of 0.05 design to NFPA 13D or NFPA 13R, use listed area of gpm/ft will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 coverage and minimum flow and pressure requirements bar). Therefore,the minimum flow required is 24 gpm @ shown in Bulletin 135. 24 psi (90.8 L/min @ 1.65 bar). For systems designed to NFPA 13, use information in this bulletin.The number of design sprinklers shall be the Example No. 2 most hydraulically demanding sprinklers as required by Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) NFPA 13. Flows and pressures can not be below the 2 2 Coverage Area= 8 2 20= 160 ft2 M2) baseline flows and pressurers. density= 160 x 0.10 = 16 gpm NFPA 13 Flow @ 0.10 gpm/ft Using an F1 Res 49 Pendent Sprinkler, K=4.9 For residential sprinkler systems designed to NFPA 13, Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) a minimum density of 0.1 gpm/ft must be provided over The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) the "design area"that includes the four(4) hydraulically coverage area using the baseline density of 0.05 most demanding sprinklers for the actual coverage gpm/ft will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 areas being protected by the 4 sprinklers. The minimum required discharge from each of the four most bar). Therefore,the minimum flow required is 20 gpm @ hydraulically demanding sprinklers shall be the greater 16.7 psi (75.7 L/min @ 1.14 bar). of the following: 1.The flow rates given in the Reliable Residential Example No.-3 Sprinkler Technical Bulletins referenced in Table A Room Size= 10 ft x 16 ft(3.0 m x 4.91 m) for NFPA 13D and 13R as a function of temperature Coverage Area= 10 x 16 = 160 ft2(14.9 m2) rating and maximum allowable coverage area (for Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm actual coverage areas less than or between those Using an F1 Res 76 Pendent Sprinkler, K=7.6 indicated in the respective technical bulletin, it is The baseline flow for a 16 ft x 16 ft coverage area is 21 required to use the minimum required flow for the gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the next largest coverage area); or minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 2.A minimum discharge density of 0.1 gpm/ft2 L/min @ 0.52 bar). applied over the"design area"consisting of the four most hydraulically demanding sprinklers for the Example No. 4 actual coverage areas being protected by the four Room Size= 14 ft x 18 ft(4.3 m x 5.5 m) sprinklers. The maximum dimension of the actual Coverage Area= 14 x 18 = 252 ft2(23.6 m2) coverage area cannot be any greater than the 2 maximum coverage area indicated in the technical Flow @ 0.10 gpm/ft density= 252 x 0.10 = 25.2 gpm bulletins referenced in Table A. min) Using an F1 Res 76 Design Note: Using the AS - S x L method to Using a endent Sprinkler, K=7.6 determine the sprinkler protection area of coverage Pressure= (252/7.6)2 = 11 psi (0.76 bar) in accordance with NFPA 13, apply the 0.1 gpm/ftc The baseline flow and pressure of an 18 ft x 18 ft density to this area to determine the minimum coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 required flozyv. Compare this flow to the minimum bar). Therefore, the minimum flow and pressure is 25.2 0.05 gpm/ft cULus Listed flow for the appropriate gpm @ 11 psi (94.6 L/min @ 0.76 bar). coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the In general residential sprinklers require technical bulletin is less than the calculated 0.1 flows and pressures as listed for 0.05 gpm/ft density flow required, the .1 density flow densities to achieve the proper spray pattern must then be used in the equation Q=K-/P, solving so the flows and pressures at 0.05 density are for P, to establish the minimum required pressure the baseline flows and pressures. Flows and using the sprinkler K-factor. Note: In many cases pressures below the listed 0.05 density shall the listed flow of individual residential sprinkler not be used. may exceed the required minimum 0.05 gpm/ft density. Reliable has available residential sprinklers with larger K-factors (K=5.8 and K=7.6) that w$ provide lower pressure demands for 0.1 gpm/ft densities in NFPA 13 residential applications. 2. Installation Models F1 Res sprinklers are to be installed as use only the Model GFR2 Sprinkler wrench. Use of shown. Model F1, F2 and FP Escutcheons, illustrated wrenches other than those specified may damage herewith,are the only recessed escutcheons to be used these sprinklers. with Model F1 Res sprinklers. Use of any other Note:A'leak tight"sprinkler joint can be obtained with recessed escutcheon will void all approvals and the following torque: warranties. For installing Model F1 Res Pendent • 3/4" NPT(193/4)— 14-20 ft-Ibs (19- 27.1 N-m) sprinklers use only the Model D sprinkler Wrench; for . '12" NPT(191/2)—8-18 ft-Ibs (10.8—24.4 N-m) installing Models F1 Res Recessed Pendent, CCP Do not tighten sprinklers over maximum sprinklers use only the Model GFR2 sprinkler wrench; recommended torque. It may cause leakage or for installing Model F1 Res recessed HSW sprinklers impairment of the sprinklers. • Model F1 Res 49, 58 & 76 • Model F1 Res 49, 58 & 76 Pendent Recessed Pendent/ F1 T2 a k� I f F1 escutcheon, /" (19mm) adjustment Note: See escutcheon table for dimensions. 2 114"HOLE DIA. [5].2-1 1 15116"DIA. [49.2—] t 1"X 112"REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. I FACE OF FITTING TO CEILING DIMENSION: 3116-15 116(F1 ESCUTCHEON) qq����//ul 3/16-11/16(F2 ESCUTCHEON) 03SYO ADJUSTMENT ®a�tl� /e [s.amm] A" 135FG03 T35FG02A 2 27132"DIA. [72.2—] Fig. 1 Fig. 2 3. Technical Data: F1 Res 49 Pendent and Recessed Pendent Escutcheon*, F1 or F2, Data: Nominal Sprinkler Max. Max. Actual Sprinkler Adjustment "A„ Face of fitting to Thread Orifice Temp. Pressure Ambient K Length Tye Inch(mm) Inch(mm) ceiling Size Inch Rahn psi Temp. Inch Inch mm (mm) °F °C �) OF °C Factor (mm) F1 %(19.0) Min.=%" (19.1) _,5� (4.7-24.0) %"NPT 155 68 100 38 Max.=1 38.1 s s (R, %6"(11) 175 79 175(12) 150 66 4.9 2.25(57) F2 (12.7) Min.=l%6"(23.8) a� -,/ (4.7-17.4) Max.=1' "(38.1) ,s ,s *Note: Escutcheons F1 or F2 may be used with Model F1 Res 49&58 Recessed Pendent Sprinkler **Baseline flows and pressures for 0.05 density Deflector-to-ceiling *Deflector-to-ceiling Maximum 1" (25mm)to 41(100mm) Maximum 4' (100mm)to 8' (203mm) Max.Sprinkler Sprinkler Max.Sprinkler Sprinkler Flow Pressure Flow Pressure Spacing m(L pm) si bar Identification Spacing m(L pm) si bar Identification ft m gp ( p ) p ( ) Number SIN ft m gp ( p ) p ( ) Number SIN 12 x 12 3.6x3.6) 13(49) 7.0(0.48) 12 x 12 3.6x3.6) 15(57) 9.4 (0.65) 14 x 14 4.3x4.3 13 49 7.0 0.48 14 x 14(43x4.3) 16(60.5) 10.6(0.73) 16 x 16 4.9x4.9 13 49 7.0 0.48 R3516 16 x 16 4.9x4.9 17(64.3) 12.0 0.83 R3516 18 x 18 5.5x5.5 17 64.3 12.0 0.83 18 x 18 5.5x5.5 19 72 15.0 1.0 20 x 20(6.1 x6.1) 20(75.7) 16.7 1.14 20 x 20(6.1 x6.1) 22(83.2) 20.2(l.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7" (178mm) 2.Beam spacing at or greater than 7.5 ft.(2.3m)on center. Technical Data: 171 Res 58 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Thread Orifice Temp. Pressure Ambient K Length Size Inch Ratina psi Tem . Factor Inch (mm) °F I °C (bar) °F °C (mm) 1/2"NPT Y2"(13) 155 68 175(12) 100 38 5.8 2.25(57) (R1/2) 175 79 150 66 **Baseline flows and pressures for 0.05 density Max.Sprinkler Flow Pressure Ceiling-to- Sprinkler Spacing gp m( p L m) ( )i bar Deflector Identification ft m Inch mm Number SIN 12 x 12(3.6x3.6) 16(61) 7.6(0.53 14 x 14(43x4.3) 16(61) 7.6(0.53) 16 x 16 4.9x4.9 16 61 7.6 0.53 (25- 00) R3513 18 x 18 5.5x5.5 19 72 10.8 0.75 20 x 20(6.1x6.1) 22(83.3) 14.4(l.0) **Calculate for a.10 density but in no case go below the baseline flows& pressures 4. Technical Data: F1 Res 76 Pendent and Recessed Pendent Nominal Sprinkler Max Max Sprinkler Thread Orifice Temp. Pressure AMIJent K Size Inch or psi T Fed � (mm) °F °C (bar) °F °C (mm) %°NPT „ 155 68 100 38 Adjustment 16,W, Face of fitting to (R%) /Z"(13.5) 175 79 175(12) 150 66 7.6 2.25(57) Type Inch(mm) Inch(mm) ceiling Inch mm *Baseline flows and pressures for 0.05 density F1 (19.0) Max-1 21I(38.1) is 'is(4.7 24.0) F2 %(12.7) Min.='%; "(23.8) /,6-„/ (4.7-17.4)Sprinkler Flow Pressure Sprinkler Max—1z„(38.1) Spacing gp Identification ft m m(Lpm) psi(bar) Number SIN 12 x 12 3.6x3.6 21 7.6 0.53 14 x 14 4.3x4.3 21 7.6 0.53 16 x 16 4.9x4.9 21 7.6 0.53 R7618 *Calculate for a .10 density but in no case 18 x 18(5.5x5.5) 21 7.6(0.53) go below the baseline flows & pressures 20 x 20(6.1x6.1) 23 9.2(0.63) • Model F1 Res 49, 58 & 76 Model F1 Res 49, 58 & 76 CCP Pendent Recessed Pendent/ FP FP push-on/thread-off escutcheon 2 518”[66.7mm] DIA. 2 518°DIA.[66.7-] 2 5116" DIA, HOLE IN CEILING HOLE IN CEILING [58.7mm] 2 5116"DIA. GDP y--- [58.7mmJ CUP }— - � �----- x1/2" REDUCER I CUP X 112°REDUCER _` ----I_—___ CEILING L 03 1 114"[31.5mm] 1\ f MAX. FACE of FITTING / ro FACE of CEILING- DIMENSION L J CEILING B•, COVER ADJUSTMENT HEIGHT ®�$du :FACE"[ae.1-1 MAX. OF FITTING - - -- - CE OF CEILING DIMENSION 3 5175" DIA. 135FG04C [84.1 mm] 1/2"[1J—]MAX. F1 R E S 49, 58 & 76 CCP P E N D. FP ADIUSTMENT +° Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1"X 3�4" reducer. 5. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/ FP CCP Options Data: Nominal Spdnkier a, Max � SOON "A" Thread Orifice Temp. Temp. pyre Ambia7t K Length Cover Adjustment CCP Height Size Inch Rating Refim psi Temp. Factor Inch Inch mm Inch mm (mm) of oC of oC (bar) of oC (mm) %(12.7) 15 24 (4.7) 3 (1 9) I/(NP �s^(11) 155 68 135 57 175(12) 100 L38 4.9 (57) ��� a *Baseline flows and pressures for 0.05 density FP Data "A": Max.Sprinkler Flow Pressure Sprinkler FP Position A Spacing Identification Inch mm ft m gpm(Lpm) psi(bar) Number SIN Max. Recessed 10 12 x 12 3.6x3.6 13 49 7.0 0.48 Min. Recessed 1%6(24) 14 x 14 4.3x4.3 13 49 7.0 0.4s Note: Sprinklers shown in Fig. 3 and Fig. 4 are not 16 x 16 4.9x4.9 14 53 8.2(0.56)- R3516 suitable for installation in ceilings which have 18 x 18(5.5x5.5) 18(68.1) 13.5(0.93) positive pressure in the space above. 20 x 20 6.1 x6.1 20 75.7 16.7(l.14) Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Nominal Sprinkle Max Max Sprinkler Thread Orifice Temp Temp. Pmssue Ambient K Length Size Inch Falling Rating Temp, Temp. Factor Inch (mm) of oC of oC (bar) of oc (mm) (RP; 1/2"(13) 155 68 135 57 175(12) 100 38 5.8 2.25(57) *Baseline flows and pressures for 0.05 density Max.Sprinkler Sprinkler Flow Pressure Spacing Identification ft m gpm(Lpm) psi(bar) Number SIN 12 x 12 3.6x3.6 16 61 7.6 0.53 14 x 14(4.3x4.3) 16(61) 7.6(0.53) 16 x 16 4.9x4.9 16 61 7.6 0.53 R3513 18 x 18 5.5x5.5 19 72 10.8 0.75 20 x 20(6.1x6.1) 22(83.3) 14.4(l.0) Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Nominal Sprinkler Max Max Sprrilder Thread Orifice Temp yT Pressue Ambient K two Size Inch �g psi Temp. Factor Inch (mm) of oC of oC Q* of oC (MM) 3/a"NPT 1Y32" 155 68 135 57 175(12) 100 38 7.6 2.25 (R3/4) (13.5) 175 79 150 66 (57 *Baseline flows and p ressures for 0.05 dens!ty Max.Sprinkler Sprinkler Flow Pressure Spacing Identification ft m gpm(Lpm) psi(bar) Number SIN 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14 4.3x4.3 21 7.6 0.53 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 *Calculate for a .10 density but in no case 18 x 18 5.5x5.5 22 8.4 0.58 go below the baseline flows&pressures 20 x 20(6.1 x6.1) 25 10.8(0.74) 6. • Model F1 Res 44 & 58 HSW Model F1 Res 44 & 58 Recessed HSW/F2 F2 escutcheon, /" (13mm) adjustment Technical Data: F1 Res 44 HSW & HSW/F2 Escutcheon, F2, Data: Thread Nominal p. K Type Adjustment Face to Fitting Size Inch psi T F� � Inch(mm) Inch mm (mm) OF °C (bar) °F eC (mm) F2 z(13) 3, -",s(4.7-17.4) 1/2"NPT Y8"(10) 155 68 175(12) 100 38 4.4 2.45(62) (R/2) 175 79 150 66 *Baseline flows and pressures for 0.05 density «A„ Max.Sprinkler Sprinkler Temp. Flow Sprinkler Ceiling-to- Pressure Spacing Deflector Rating glom Pressure (bar) Identification ft(m) Inch(mm) F(C) (Lpm) Number(SIN) 12 x 12 3.6x3.6 155 68 175 79 12 45.4 7.5 0.52 14 x 14 43x4.3 155 68 175 79 14 53.0 10.2 0.71 16 x 16 4.9x4.9 4-6 155 68 175 79 16 60.6 13.3 0.92 16 x 18(4.9x5.5)- (101-152) 155 68 175 79 18 68.1 16.8(l.16) 18 x 18 5.5x5.5 155 68 175 79 19 72.0 18.7(l.29) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(l.89) R3531 12 x 12 3.6x3.6 155 68 175 79 14 53.0 10.2(0.71 14 x 14 43x4.3 155 68 175 79 16 60.6 13.3 0.92 16 x 16 4.9x4.9 6-12 (152-305) 155 68 175 79 17 64.4 15.0 1.04 16 x 18 4.9x5.5 155 68 175 79 20 75.7 20.7(l.43) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(l.89) *Calculate for a .10 density but in no case go below the baseline flows& pressures 7. • Model F1 Res 44 SWC 4"to 12" f,01.60- I. 1 114"[31.75mm]Maximum 304.80mm] Foce Of Fttiny PUSH ON COVER, THEN To Wall Dimension TURN TO ADJUST UNTIL AGAINST WALL. 1"X 112"Reducer 4TIGHT Recommended Wall Hale 2 5/16"2 5/8" [58.74-1 =--- -�- 3 5/16" it [84.14mm] Dio. Dio. TURN COLLAR UNTIL .n TIGHT AGAINST SPRINKLER u 1 21/32° WRENCH BOSS. [42.07mm] 135FG07 -� 112"[12.70mm] Adjustment F1 RES 44 SWC Fig. 5 Technical Data: F1 Res 44 SWC Nominal Sprinkiff Co wTemp Max Marc Sp t lft Thread Orifice Temp. �g Pressure q�.�*T� K I.erx�IN she Inch fin psi Factor Inch (mm) OF °C °C (bar) °F cc (mm) Y2RN�T %"(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62) *Baseline flows and pressures for 0.05 density Max.Sprinkler «A„ Flow Sprinkler Spacing Ceiling to- gpm Pressure Identification ft(m) Inn hl mmr (fpm) psi(bar) Number(SIN) 12 x 12 3.6x3.6 13 49.2 8.7 0.60 14 x 14 4.3x4.3 14 53.0 10.2 0.71 16 x 16(4.9x4.9) (101 6 17 64.3 15.0 1.1 16 x 18 4.9x5.5 19 71.8 18.7(l.13) 16 x 20 4.9x6.1 23 87.1 27.4 1.89 R3531 12 x 12(3.6x3.6) 14(52.9) 10.2(0.71) 14 x 14(4.3x4.3)- 6-12 15 56.7 11.7 0.81 16 x 16 4.9x4.9 (152-305) 18 68.1 16.8(l.16) 16 x 18(4.9x5.5) 20(75.6) 20.7(l.43) *Calculate for a .10 density but in no case go below the baseline flows& pressures 8. Technical Data: F1 Res 58 HSW & HSW/F2 Escutcheon, F2, Data: Nominal Sprinkler Max. Max. Sprinkler Adjustment Face of Fitting Thread Orifice Temp. pressure Ambient K Length Type Inch(mm)mm) to wall Size Inch Ratin psi Tem P. Factor Inch Inch mm (mm) OF -C (bar) OF OC (mm) F2 %(i3) Y116-'%6(4.7-17.4) 1/2"NPT Y2"(13) 155 68 175(12) 100 38 5.8 2.45(62) (R/2) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max.Sprinkler A Sprinkler Temp. Flow Sprinkler Spacing Ceiling-to- Rating gpm Pressure Identification ft(m) Deflector OF(°C) (Lpm) psi(bar) Number(SIN) Inch mm 12 x 12 3.6x3.6 155 68 175 79 16 60.6 7.6 0.53 14 x 14 4.3x4.3 155 68 175 79 18 68.2 9.7 0.67 16 x 16 4.9x4.9 (101-4 156 2) 155 68 175 79 21 79.5 13.2 0.91 16 x 18 4.9x5.5 155 68 175 79 25 94.7 18.6(l.28) 16 x 20(4.9x6.1) 155(68) 175(79) 29(109.8) 25(1.73) R3533 12 x 12 3.6x3.6 155 68 175 79 22 83.3 14.4(l.0) 14 x 14 4.3x4.3 6-12 155 68 175 79 22 83.3 14.4(l.0) 16 x 16 4.9x4.9 (152-305) 155 68 175 79 26 98.4 20.1 1.39 16 x 18(4.9x5.5) 155(68) 175(79) 31 (117.4) 28.6(l.97) *Calculate for a .10 density but in no case go below the baseline flows&pressures Finishes(l) Ordering Information Standard Finishes Specify Sprinkler F1 F2 FP Escutcheons 1. Sprinkler Model Bronze Brass Chrome Plated Bright Chrome Plated 2. Sprinkler Type White Polyester Coated White Painted 3. Temperature Rating Special Application Finishes 4. Sprinkler Finish Sprinkler F1,F2, Escutcheons 5. Escutcheon Finish Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult factory for details. 9. Maintenance Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers Model F1 Res 49 & 58 Recessed Pendent/F1, should be inspected quarterly, and the sprinkler system Model F1 Res 49 & 58 Recessed Pendent/F2, maintained in accordance with NFPA 25, 13, 13D, and Model F1 Res 49 & 58 Recessed Pendent/FP 13R. Do not clean sprinkler with soap and water,Ammonia Sprinklers shall be [cULus Listed] [New York City MEA or any other cleaning fluids. Remove dust by using a soft Approved (258-93-E)] low flow residential recessed brush or gentle vacuuming. Remove any sprinkler which pendent sprinklers engine red to provide a minimum has been painted(other than factory applied)or damaged design density of 0.10 gpm/ft t over the listed coverage area. in any way. A stock of spare sprinklers should be Listed flows as specified by the manufacturer's technical maintained to allow quick replacement of damaged or data sheets are to be used. Residential sprinklers shall be operated sprinklers. Prior to installation, sprinklers should installed in conformance with the manufacturer's installation remain in the original cartons and packaging until used. guidelines and the applicable installation standard. Where This will minimize the potential for damage to sprinklers that pendent residential sprinklers are installed under sloped could cause improper operation or non-operation. ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance Model F1 RES 49 Residential listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a /2" Sprinkler Specifications NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic Model F1 Res 49 & 58 Pendent parts, and having a temperature rating of [155°F (68 0C)] Sprinklers shall be [cULus Listed] [New York City MEA [175°F(79 0C)]. Sprinklers shall have a nominal K-factor of Approved (258-93-E)] low flow residential pendent 4.9(70). Standard finish: [Bronze] [Chrome-plated] [White sprinklers engineered to provide a minimum design Polyester] [Special finish—specify]. Recessed escutcheon density of 0.10 gpm/ft2 over the listed coverage area. assembly shall be a steel, two-piece escutcheon [with 112" Listed flows as specified by the manufacturer's technical adjustment(Model F2)] [with 3/a"adjustment(Model F1)] [of data sheets are to be used. Residential sprinklers shall be push-on and thread off design with 1/2" adjustment (Model installed in conformance with the manufacturer's FP)]. Standard finish shall be [brass][bright chrome] [white installation guidelines and the applicable installation painted]. Residential recessed pendent sprinklers shall be standard. Where pendent residential sprinklers are Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] installed under sloped ceilings having a pitch of up to[4/12] [Model F1 Res 49 &58 Recessed Pendent/F21 [Model F1 [8/12], the sprinklers shall be listed for such use. Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 Deflector-to-ceiling distance listing shall be 1" to 8" (Bulletin 135). maximum.Sprinkler frame and deflector shall be of bronze Model F1 Res 49&58 CCP Pendent(Concealed) frame construction having a '/2" NPT thread. Water seal Sprinklers shall be[cULus Listed] [New York City MEA assembly shall consist of a Teflon-coated Belleville spring Approved 258-93-E low flow residential concealed washer and top-loaded extruded cup with 3 mm glass bulb sprinklers l engineered] to provide a minimum design containing no plastic parts, and having a temperature density of 0.10 gpm/ft2 over the listed coverage area. rating of [155°F (68 0C)] [175°F (79 0C)]. Sprinklers shall Listed flows as specified by the manufacturer's technical have a nominal K-factor of 4.9 & 5.8. Standard finish: data sheets are to be used. Residential sprinklers shall [Bronze][Chrome-plated][White Polyester][Special finish— be installed in conformance with the manufacturer's specify]. Residential pendent sprinklers shall be Reliable installation guidelines and the applicable installation Model F1 Res 49&58,SIN R3516&R3513(Bulletin 135). standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 112" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68 0C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover plate adjustment. Cover plate temperature rating shall be 135°F(57 0C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 49 &58 CCP, SIN R3516 & R3513 (Bulletin 135). 10. Model F1 Res 44 & 58 Horizontal Sidewall Model F1 Res 76 Recessed Pendent/F1, Sprinkler Model F1 Res 76 Recessed Pendent/F2, Sprinklers shall be [cULus Listed] [New York City MEA Model F1 Res 76 Recessed Pendent/FP Approved (258-93-E)] low flow residential horizontal Sprinklers shall be [cULus Listed] low flow residential sidewall sprinklers engineered to provide a minimum recessed pendent sprinklers engineered to provide a design density of 0.10 gpm/ft2 over the listed coverage minimum design density of 0.10 gpm/ft over the listed area. Listed flows as specified by the manufacturer's coverage area. Listed flows as specified by the technical data sheets are to be used. Residential manufacturer's technical data sheets are to be used. sprinklers shall be installed in conformance with the Residential sprinklers shall be installed in conformance manufacturer's installation guidelines and the applicable with the manufacturer's installation guidelines and the installation standard. Where horizontal sidewall applicable installation standard. Sprinkler frame and residential sprinklers are installed under sloped ceilings deflector shall be of bronze frame construction having a having a pitch of up to [4/12] [8/12], the sprinklers shall 3/4" NPT thread. Water seal assembly shall consist of a be listed for such use.Sprinkler frame and deflector shall Teflon-coated Belleville spring washer and machined be of bronze frame construction having a'/z"NPT thread. cup with 3 mm glass bulb containing no plastic parts,and Water seal assembly shall consist of a Teflon-coated having a temperature rating of [155°F (68 0C)] [175°F Belleville spring washer and top-loaded extruded cup (79 0C)]. Sprinklers shall have a nominal K-factor of 7.6. with 3 mm glass bulb containing no plastic parts, and Standard finish: [Bronze] [Chrome-plated] [White having a temperature rating of [155°F (68 1C)] [175°F Polyester] [Special finish- specify]. Recessed (79 0C)]. Sprinklers shall have a nominal K-factor of 5.8. escutcheon assembly shall be a steel, two-piece Standard finish: [Bronze] [Chrome-plated] [White escutcheon [with 1/2" adjustment (Model F2)] [with 3/4" Polyester] [Special finish-specify].Residential horizontal adjustment(Model F1)][of push-on and thread off design sidewall sprinklers shall be Reliable Model F1 Res 58, with 1/2" adjustment(Model FP)]. Standard finish shall be SIN R3513 (Bulletin 135). [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable[Model F1 Model F1 Res 44 & 58 Recessed Res 76 Recessed Pendent/Fl] [Model F1 Res 76 Horizontal Sidewall Sprinkler Recessed Pendent/F2] [Model F1 Res 76 Recessed p Pendent/FP] SIN R7618 (Bulletin 135). Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed Model F1 Res 76 CCP Pendent (Concealed) horizontal sprinkler." Add: Recessed escutcheon Sprinklers shall be [cULus Listed] low flow residential assembly shall be a steel,two-piece escutcheon with'/2" concealed sprinklers engineered to provide a minimum adjustment (Model F2). Standard finish shall be design density of 0.10gpm/ft over the listed coverage area. [brass][bright chrome] [white painted] [Special finish- Listed flows as specified by the manufacturer's technical specify]. Residential recessed horizontal sidewall data sheets are to be used. Residential sprinklers shall be sprinklers shall be Reliable Model F1 Res 58/F2, SIN installed in conformance with the manufacturer's installation R3513 (Bulletin 135). guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame Model F1 Res 76 Pendent construction having a3/4"NPT thread. Water seal assembly Sprinklers shall be [cULus Listed] low flow residential shall consist of a Teflon-coated Belleville spring washer and machined cup with 3 mm glass bulb containing no plastic pendent sprinklers engineered to provide a minimum parts, and having a temperature rating of 155°F (68 0C). design density of 0.10 gpme over the listed coverage area. Cover plate assembly shall consist of a brass cover plate Listed flows as specified by the manufacturer's technical and copper alloy retainer flange. Method of attaching the data sheets are to be used. Residential sprinklers shall be cover plate to the sprinkler cup shall be a push-on and installed in conformance with the manufacturer's installation thread-off design allowing a 112" cover plate adjustment. guidelines and the applicable installation standard. Cover plate temperature rating shall be 135°F (57 0C). A Sprinkler frame and deflector shall be of bronze frame plastic protective cap shall be provided and factory installed construction having a3/4" NPT thread. Water seal assembly inside the sprinkler cup to protect the sprinkler from shall consist of a Teflon-coated Belleville spring washer and damage,which could occur during construction before the machined cup with 3 mm glass bulb containing no plastic cover plate is installed. Standard cover plate finish: [White] parts, and having a temperature rating of [155°F (68 0C)] [Custom Color- specify]. ]. Concealed pendent sprinklers [175°F(79 0C)]. Sprinklers shall have a nominal K-factor of shall be Reliable Model F1 Res 76 CCP,SIN R7618(Bulletin 7.6. Standard finish: [Bronze] [Chrome-plated] [White 135). Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). 11. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances,whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by RIM, Q The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices Recycled (800)848-6051 Sales Fax Paper iable � (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/08 P/N 9999970322 Bulletin 157 Rev. I R Model F3QR R liable Quick Response , Dry Sprinklers Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent -~ • Recessed FP Pendent `x • Recessed F1 Pendent • Concealed Pendent Pendent/HB • Horizontal Sidewall (See Fig. 1) (See Fig. 2) • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 1112"(38mm)escutcheon adjustment on pendent sprinkler. 4. 112" (13mm) escutcheon adjustment on recessed sprin- kler with push-on/thread-off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on/thread-off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass Recessed FP Pendent Concealed bulb and galvanized nipple. (See Fig.3) (See Fig. 4) 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51mm -to - 1219mm), in ?/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. " US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals Recessed F1 Pendent Horizontal Sidewall 1. Listed by Underwriters Laboratories Inc. and UL (See Fig.5) (See Fig.6) Certified for Canada (cULus) Style Response Sprinkler Hazard System Type Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction (R5714) Horizontal Sidewall Wet Pipe Horizontal Sidewall HB / Recessed Horizontal Sidewall Quick Dry Pipe Light (See Fig. 7) (R5734) All Preaction 2. Certified by FM Approvals Style Response Sprinkler Hazard tY p S stem Type 6M� Pendent Wet Pipe Light yS Recessed F1 Pendent Quick Dry Pipe Ordinary, (R5714) All Preaction Groups 1&2 Horizontal Sidewall Wet Pipe Recessed FP Recessed F1 Recessed F1 Horizontal Sidewall Quick Dry Pipe Light Horizontal Sidewall Horizontal Sidewall (85734) All Preaction (See Fig. 8) (See Fig. 9) 3. NYC MEA 258-93-E The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler Model F3QR Dry Pendent w/HB Escutcheon "A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4"(6mm)increments "A"Dim. 31/z"to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes`') Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Bronze Brass(3) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Ratin White Polyester(Z) White Ordinary 135°F (57°C) 100°F (38°C) Orange (1)Other finishes and colors are available on special order. Ordinary 155°F (68°C) 100°F (38°C) Red Consult factory for details. Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate 200°F (93°C) 150°F (66°C) Green White. High(1) 286°F 141°C 225°F 107°C Blue (3)Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. ------------ (1)Listed and Certified only by cULus. = �F===1; ] I— ---4—II�I�F— `7===��'�s'_, u- �System Tee Ail 1"NPT System Tee 2 1/8" Di, [54nOmm] 1"NPT °A" im ion ens Hole i Ceiling °A"Dimension 2 1/2 [6 n.5mm] Adjustment Range Dla. Hole Coding —1/4" [-6.4mm] 1 43/6 Dia. 1/2"men}Range +1 1 4' +31.Smm / 1 1 2' 38.1mm -1/2"[-12.7mm] Escutheo[Bmm] / [ ] [42.5mm] / [ ] +1/2"[+12.7mm] Totol Adjustment Sprinkler Con 1/2"[12.7mm] Ceiling 1 1/4" [31.Smm] Escutheon Adj. 1/4° [6.4mm] Gaffing 1"[25.4] Escutcheon Escutcheon Total Adj. Ceiling Adjustment Escutcheon 1/2"[12.7mm] Escutheon Adj. Nominal Position Sprinkler ten of Escutcheon 1 5/8" of Es Nominal Position [41.3m m] 1-1/4"[31.75m"1 of Escutcheon 1 5 Nominal Protrusion [41.5 1/4" [6.4mm] Protrusion 3" Did. [76.2mm] NEW757FG01 NFN'15]FGG2 2 13/64"[55.88mm] Fig. 1 Dia. Fig. 2 Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/4"(-6mm)to +11/4" Note: The sprinkler can protrudes 11/4" when escutcheon is to (+32mm)"A"dimension adjustment range. nal position. Escutcheon adjustment provides-1/2"(-12.7mm)to +1/2"(+12.7mm)"A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F30R Dry Recessed FP Pendent S rinkler "A"Dim. 31/z"to 48" 89mm to 1219mm in 1/4" 6mm increments ---- --- -piTF===z Finishes") - Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated System Tee White Polyester(2) White 1/z" ,° NPT z Din. [1]Other finishes and colors are available on special order. [s3.bumm] Consult factory for details.Cup remainds unfinished. "A" Dimension Hole in ceiling ment Range' Only the escutcheon will contain desired finish. Adjust 2 19/64" Dia. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or [+5.35mm] [58.34mm] White. Nominal Position Sprinkler Standard Temperature Ratings of Escutcheon Cup Assembly Sprinkler Max. Classification Temperature Ambient Bulb Color Ceiling Escutcne°" Ratina Temp. ceiling Ordinary 135°F (57°C) 100°F (38°C) Orange 1/4° [6.35mm] Ordinary 155°F (68°C) 100°F (38°C) Red Escutcheon Adjustment o 1/4" [6.35mm] 3 7/32" Din. Intermediate 175°F (790C) 150°F (66°C) Yellow Escutcheon Adjustment Intermediate 200°F (93°C) 150°F (66°C) Green [8,76mm High(1) 286°F 141°C 225°F 107°C Blue Total Adjustment NEW157FG03 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig. 3 for interior applications. Note: Do not install the Model F3OR Dry Recessed FP Pendent Sprin- M Listed and Certified only by cULus. kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 2. Model F3QR Dry Pendent Concealed Sprinkler "A"Dim. 31/2'to 48"(89mm to 1219mm)in 1/4"(6mm)increments �____ z_ rr p F=== CCP Cover Plate") Finishes`2' -� -�! - Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated s stem Tee White Black Plated Sy stern NPT Black Paint z 112" of°. Off White 6.35mm] Satin Chrome "A" Dimension Hole in Ceiling (1)Utilizes the 1/2"cover plate with 3/8"total adjustment. Ad;u tm3/16Range 2 19/64" Did. (2)Other finishes and colors are available on special order. [t4.76mm] [58.34mm] Consult factory for details. Nominal Position of Coverplate Sprinkler Cup Assembly Standard Temperature Ratings Coverplate Sprinkler Max. Ceiling As Classification Temperature Cover Plate Ambient '��3 Temp.Rating Rating Temp. 3/16" [4.76mm] Coverplate Adjustment Ordinary 135-F (57°C) 135°F (57°C) 100°F (38°C) 3/16" [4.76mm] F Ordinary 155-F (68°C) 135°F (57°C) 100°F (38°C) co erpl°te Adjustment 3 s/16" Dio. [84.16" D Intermediate(1) 175°F (79°C) 165°F (74°C) 150°F (66°C) s/s° [9.53mm] Intermediate 200-F (93°C) 165°F (74°C) 150°F (66°C) Total Adjustment NEW757FG04 High(1) 286°F(141°C) 165°F (74°C) I 150°F (66°C) Fig. g� Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler brass and recommended for interior applications. in ceilings which have positive pressure in the space above. (1)Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Finishes(1) --- ` ___ ___=1''1 11 Sprinkler Escutcheon Collar -�fl--j — I- Chrome Plated Chrome Plated Chrome Plated White Polyester(2) White White ti - System Tee Other finishes and colors are available on special order. Consult factory for details. 2 1/2° Din. NPr (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or [63.50mm] Hole in Ceiling White. 1 15/16" "A" Dimension [49.2mm] Adjustment Range Standard Temperature Ratings t 1/4° [f6.35mm] Sprinkler Max. 15/16" Nominal Position [ ] Sprinkler Classification Temperature Ambient Bulb Color of Escutcheon cup Assembly Rating Temp. Ceiling Ordinary 135°F (57°C) 100-F (38°C) Orange I I ceuing [3.2mm] Ordinary 155°F (68°C) 100-F (38°C) Red 1/4° [6.35] Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Essamhenn Adjustment f Intermediate 200°F (93°C) 150-F (66°C) Green /4° r6.31] High 1j 286°F(141°C) 225°F(107°C) Blue Escutcheon Adjustment VE 1/2" [12.7mm] 2 27/32" Adjustment �I NEwvS7FCOS [72.2mm] Listed and Certified only by cULus. Fig. 5 Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 3. Model F3QR Dry Horizontal Sidewall Sprinkler Model F3QR Dry HSW w/HB Escutcheon "A"Dim. 2"to 48" 51 mm to 1219mm in 1/4"(6mm)increments "A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4"(6mm)increments Finishes"' s rinkler Escutcneon Standard Temperature Ratings Bronze Brass(3) Chrome Plated Chrome Plated Sprinkler Max. White Polyester(2) White Classification Temperature Ambient Bulb Color Rating Temp. Other finishes and colors are available on special order. Ordinary 135-F (570C) 100-F (380C) Orange 2 Consult factory for details. Ordinary 155-F (680C) 100OF (380C) Red cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate(1) 1750F (790C) 150OF (660C) Yellow White. Intermediate 200-F (93oC) 150OF (660C) Green 3)Not available for HB escutcheons. High 286-F(1410C) 2250E 10700 Blue 1 1/2° [38.10mm] Sprinkler can and escutcheon fabricated of brass for better weather Total Adjustment resistance in exterior applications. Ceiling 1"[254—]75 4" [101.60mm] Mi Total Adjustment Ceiling 1 1/4" [31.75mm] 12" [304.80mm] Mc r Escutcheon Adjustment 1/ch on Adj m] T 1/4" [6.35mm] Escutcheon Adjustment 4"[701.60mm] Min. System Tee Escutcheon Adjustment 1/2"[727mm] 12" [304.60mm] M- 1" NPT Escutcheon Adjustment 2 3/32" 2 3/32" System Tee 3 [53.tamm] [53.18mm] 3' 2-13/fi4" dis Dia. [68.9mm] Escutcheon Mo. 2 1/8" Did. a. I ri [53.98mm] '� L2 1/2" Do 63.Smm] Hole In Wall 1/4" [6.35mm] Hole n Wall 1-1/4"[31.75mm] Nominal Sprinkler Can Protrusion Protrusion Sprinkler Can "A" Dimension "A"Dimension Escutcheon Nominal Position Adjustment Adjustment of Escutcheon Ncwrn 7 Range + 1/2"[+12.7mm] of Escutcheon l ion Range - 1/4' [-6.35mm] - 1/2" [-12.7mm] mcwrs7FCOS + 1 1/4 [+31.75mm] Fig. 6 Fig. 7 Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- position. Escutcheon adjustment provides?/4"(-6mm)to +11/4" nal position. Escutcheon adjustment provides-1/2"(-12.7mm)to (+32mm)"A"dimension adjustment range. +1/2"(+12.7mm)"A"dimension adjustment range. (1)Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 Sprinkler Wrench prinkler Identification Number(SIN): R5734 Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/d'(6mm)increments F _°e_°_in9__� Finishes"' Lf Escutcheon 1 13/32" [35.7mm] Sprinkler Escutcheon sy=tdm Tee Cup 3 2'[3a48m]MO;<* Bronze Brass Chrome Plated Chrome Plated 1"NPT White Polyester(2) White "� n 3 7/32"Dia. (1)Other finishes and colors are available on special order. Consult factory for details.Cup remainds unfinished."See page 2" (2) cl-Lus Listed as a Corrosion Resistant sprinkler in standard Black or 2 1/2"Dia [63.SmWe — Nomi not Position White. ale Well 3 of Escutcheon White. 2 19/64"Dia. [58.3mm] " Standard Temperature Ratings Escutcheon Ad;uetment "A"Dimension Adjustment Range A0[12.7mm] NEw151FGOB 21/4" Escutcheon Adjustmenk Classification Sprinkler Tem- Max. Bulb Color f6.35mm] —Escutcheon[Adj-tment perature Rating Ambient Temp. =k•FOR FACTORY MUTUAL(FM) Ordinary 135-F (57oC) 100°F (38°C) Orange 4"—6"FOR UNDERWRITERS LABORATORIES(UL) Ordinary 155-F (68oC) 100°F (380C) Red Fig. 8 Intermediate(1) 1750F (790C) 150OF (66°C) Yellow Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Intermediate 200OF (93oC) 150OF (66°C) Green Sidewall Sprinkler in walls which have positive pressure in their High(1> 2860F(141-C) 2250F(1070C) Blue side space. • Listed by cULus for Quick Response. Approved by FM for (1)Listed and Certified only by cULus. Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cl-Lus Sprinkler Installation Wrench: for installation of min.4"(100mm)-to-max.6"(150mm)below Model 33 R/C Sprinkler Wrench ceiling and approved by FM for installation of min.4"(100mm) Sprinkler Identification Number(SIN): R5734 -to-max. 12"(300mm)below ceiling. 4. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/a"(6mm)increments F ceaing i Finishes Escatcheon — �[3.2mm] Sprinkler Escutcheon ICollar 4° [101.6mm]Min. System Tee Sprinkler Cup 3 12"[304.8mm]Mox.* Chrome Plated Chrome Plated Chrome Plated Assemhly White Polyester(2) White White 1„ NET �- (1)Other finishes and colors are available on special order. Consult factory for details. - - - - 2722mm (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. ` I 2[1/2" Die. 63m .5m] Standard Temperature Ratings H°lei wall Nominal Position 1 15/16" of Escutcheon Sprinkler Max. [a9.2mm] p 1/4° [sss] Classification Temperature Ambient Bulb Color Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] Rating Temp. NEW157FC09 Adjustment Range Adjustment # 11/4 3sm" m] eh j Ordinary 135°F (57oC) 100-F (38eC) Orange FOR FACTORY MUTU AL (FM) Ee�te n A stmet Ordinary 155-F (68oCi) 100-F (38eC) Red 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Intermediate(1> 175°F (79oC) 150oF (66eC) Yellow Intermediate 200°F (93oC) 150-F (66eC) Green Fig. 9 High(1) 286-F(1141-C) 225°F(107°C) Blue • Listed by cULus for Quick Response.Approved by FM for Standard Response. (')Listed and Certified only by cULus. • Recessed Horizontal sidewall sprinklers are listed Sprinkler Installation Wrench: with cULus for installation of min. 4" (100mm) - to Model G3 R/C Sprinkler Wrench -max. 6" (150mm)below ceiling and approved by Sprinkler Identification Number(SIN): R5734 FM for installation of min.4"(100mm)-to-max. 12" (300mm)below ceiling. Technical Data: Ordering Information Orifice Size:'/z" (15mm) Specify: Thread Size: 1" NPT per ANSI B2.1 1. Sprinkler Type (select one): Working Pressure: 175 psi (12 bar) (a) Model F3QR Dry Pendent Nominal K Factor-US/(Metric):5.6/(80) (b)Model F3QR Dry PendenVH13 Product Description (c) Model F30R Dry Recessed FP Pendent Reliable Model F3QR Dry Sprinklers are quick response sprinklers (d)Model F3QR Dry Recessed F1 Pendent utilizing a durable 3mm frangible glass bulb. This quick response (e) Model F3QR Dry Concealed Pendent enables these sprinklers to apply water to a fire much sooner than (f)Model F3QR Dry Horizontal Sidewall standard response sprinklers of the similar temperature rating. (g)Model F3QR Dry Horizontal Sidewall/HB Model F3QR Dry Sprinklers are intended for use in dry and preac- (h) Model F3QR Dry Recessed FP Horizontal Sidewall tion systems and in areas subjected to freezing temperatures,such (i) Model F3QR Dry Recessed F1 Horizontal Sidewall as freezers and unheated portions inside and outside buildings. 2. Sprinkler Temperature Rating. Environments wherein dry sprinklers are employed can be cor- 3. Sprinkler Finish. rosive.For this reason,Model F3 Sprinklers have a special wax fillet 4. Escutcheon type (F1 or FP). placed in the gap between the cup that supports the bulb and the 5. Cover Plate/Escutcheon Finish. wrenching boss.This wax will not interfere with the operation of the 6. Length: sprinkler, and it prevents contaminents from entering the internal "A" Dimension(face of tee to face of ceiling or wall)in'/4" portion of the drop nipple.The wax must not be removed. (6mm)increments. Operation 7. Model F3QR Dry Pendent (a) is available without The glass bulb consists of an accurately controlled amount of sprinkler can and escutcheon. special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide Note: fast thermal response. When the temperature increases sufficiently, 1. The "A" dimension is based on a nominally gauged due to a fire,the bulb shatters allowing operating parts to clear the pipe thread "make-up" of 0.600" (15mm) per ANSI waterway. This enables the inlet seal to release air or water and 132.1 [71/2 threads approximately]. subsequently, cause water flow over the deflector in a uniform 2. All platings and paintings are decorative and intend- spray pattern,controlling or extinguishing the fire. ed for interior use. 5. General Installation Instructions Maintenance Model F3QR dry sprinklers must be installed only in stan- The Model F30R Quick Response Dry Sprinklers should dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected quarterly and the sprinkler system maintained pipe tees in the horizontal position,even at branch line ends. in accordance with NFPA 25. Do not remove the factory They should not be installed into elbows or pipe couplings applied thermally sensitive wax fillet between the bulb sup- located on drop nipples to the sprinklers. For these and porting cup and the wrenching boss. Do not replace this other fittings including CPVC", the dry sprinkler should be wax with a substitute substance. An Alternate substance installed into a fitting to allow protrusion into the fitting in ac- may interfere with proper operation of the sprinkler. Do not cordance with the diagrams. The "A" dimension of the dry clean sprinklers with soap and water, ammonia or any other sprinkler, which extends into the freezers or a freezing zone cleaning fluids. Remove dust by using a soft brush or gently from wet pipe systems, should be selected to provide, as a vacuuming. Remove any sprinkler which has been painted minimum,the specified lengths in inches shown in Fig. 10. (other than factory applied)or damaged in any way. A stock Caution: of spare sprinklers should be maintained to allow quick Do not install Model F3QR Dry sprinklers into CPVC replacement of damaged or operated sprinklers. Prior to adapter fittings or tees that have an internal obstruction. installation, sprinklers should be maintained in the original This will damage the sprinkler and/or the fitting. Refer to cartons and packaging until used to minimize the potential Fig. 11. for damage to sprinklers that would cause improper opera- tion or non-operation. During installation, the following steps must be followed: Caution: Use specified by RASCO wrenches only, which are 1. Cut the specified size hole(see illustrations)for the sprin- designed to engage sprinkler's wrenching pad. (Fig. 15, kler in the ceiling or wall directly in line with the tee. page 9) 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on /thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model G3 R/C wrench (Fig. 12) is designed to locate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard 112" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model G3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 6. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF ORY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT PER ANSI B 16.3 (CLASS 150) AMBIENT TEMPERATURE __ r_t_----- ___ THREADED TEMPERATURE -- �T --- r-- �\ OR CAST IRON THR ED TEE FITTING OF PROTECTED 40'F/4'C 50'F/10'C 60'F/16'C I _i"1 l 1 1111 PER ANSI 16.4(CLASS 125) ONLY. AREA*Al THE DISCHARGE END EXPOSED MINIMUM BARREL LENGTH" FACE OF TEE TO TOP OF CEILING) OF THE SPRINKLER ( Lr-1 �1J IN. (MM) IN. (MM) IN. (MM) IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40'F (4'C) 0 0 0 CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED 39F (-1'C) 0 0 0 I BARREL WITH INSULATION, FOAM INSULATING 20'F (-7'C) 4 (101) 0 0 TAPE OR EQUIVALENT. I 10'F(-12'C) 8 (203) 1 (25.1) 0 O'F (-18'C) 12 (305) 3 (75) 0 MINIMUM (HEATED AREA) I SEAL THE CLEARANCE SPACE EXPOSED I AROUND THE SPRINKLER TO AVOID —10-F (-23'C) 14 (356) 4 (101) 1 (25.1) BARREL LEAKAGE OF AIR INTO THE PROTECTED —20'F (-29'C) 14 (356) 6 (152) 3 (75) LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH —30-F (-34'C) 16 (406) 8 (203) 4 (101) I COULD INHIBIT OPERATION OR CAUSE PREMATURE —40-F (-40'C) 18 (457) 8 (203) 4 (101) I RECOMMENDEDPMETHODS,SEE BELOW FOR 'A' CLEARANCE —50-F (-46'C) 20 (508) 10 (254) 6 (152) DIMENSION HOLE —60-F (-51'C) 20 (508) 10 (254) 6 (152) • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. I THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. I **THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. CEILING) ESCUTCHEON NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH WIND VELOCITIES IN THE PROTECTED AREA l (PROTECTED AREA) —3' DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE rt-----------J� nil ---- -- -- T == - ----- -- -- I--------�a - II,I 111111 I II 11 1!11 1 I .j6!-_-41 As _ Lr-� r-tiJ Lr-1 I tiJ L J L J (HEATED AREA (HEATED AREA)MINIMUM MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING INSIDE FACE SEAL LENGTH (SEE ABOVE) RA M4003910 (SEE ABOVE) (RECOMMENDED) i CLEARANCE HOLE '.'.. INSULATED FREEZER I OR COOLER STRUCTURE OR EXTERIOR FRAMING ......................... .................... ......................... ................... i (PROTECTED AREA) DRY SPRINKLER <PROTECTED AREA) DRY SPRINKLER IN COLD AREA IN COLD AREA i NEW157FG10 Fig. 10 7. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION I FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 8. [i - I1 Fig. 12-G3 R/C Wrench Fig. 13-G3 R/C Wrench Fig. 14-G3 R/C Wrench r WP,. Fig. 15-G3 Wrench 9. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. ® Recycled Relle® (800)431-1588 Sales Offices Paper iabi (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.05/12 P/N 9999970175 BERMAD RrE ProtECtion _r _F 700 SENEs 700E Deluge Valve Data Description BERMAD 700E Deluge Valves are globe valves with integral unitized double chamber actuator that consists of one single moving assembly, which includes a diaphragm assembly, a flat seal disk and a stainless steel removable seat. These automatic water control valves are designed .` for high pressure service, in vertical or horizontal installations and are available in diameter sizes from 11/2" to 16"; DN40 to DN400. The BERMAD 700E valves are used for water flow control in Deluge, Pressure Control Deluge, Preaction or Water/ Foam systems, and are manufactured from materials suitable for freshwater or alternative for seawater, foam concentrate or other corrosive fluids. The 700E Deluge Valve is held closed by system water pressure trapped in the control chamber. When the releasing system operates, pressure is released from the control chamber, and the seal disc opens to allow water to flow into the system. The 700E valve body design includes a single, full bore seat with unobstructed flow path, free of any in-line ribs, supporting cage, or stem guides. Main Features The 700E "Y Type" design provides high flow capabilities ■ High Pressure Construction— with minimum head loss. 400 psi (28 bar) rating available The integral unitized double-chambered actuator provides • Integral unitized double chamber actuator a combination of positive, immediate response with with single moving assembly smooth hammer-free, drip-tight closing. ■ In-line serviceable, field replaceable internals The whole actuator can be easily removed for a quick ■ Obstacle free, full bore in-line inspection and servicing. ■ Available in corrosion resistant materials Valve actuation is accomplished by one moving assembly ■ Designed to be reset without opening the valve which includes a replaceable flat diaphragm, harnessed ■ Compatible with electric/hydraulic/pneumatic to the diaphragm assembly, a stainless steel stem and a release and pressure control trim systems flat seal disk assembly. The balanced seal-disk assembly with its resilient seal Approvals enables controlled actuation, high durability and perfect ■ UL Listed to UL 260 from 5 to 300 psi; 0.3 to 21 bar drip-tight sealing, even under harsh conditions. WP, 2" through 10"; DN50 through DN250 ■ ABS Approved for 300 psi; 21 bar WP, 11/2" through Accessories 12"; DN40 through DN300 ■ Lloyd's Register Type Approval for 300 psi; 21 bar WP, The BERMAD 700E Deluge Valve shall be trimmed with 11/2" through 16"; DN40 through DN400 the original components and accessories per specification ■ Fire Test Certified to ISO 6182 part 5, 11/2" through and in accordance with valve functions and applications. 16"; DN40 through DN400 Where additional specifications and/or signaling devices are required for a specific application, refer to system data Notes: for the system used, and to the BERMAD data sheet and 1.The 700E valve shall be trimmed with specific components &accessories. Installation, Operation & Maintenance for specific model 2.The 700E valve must be installed and maintained in required. compliance with the most recent BERMAD publications. A BERMAD RPE ProtECtion 700E Materials - 700 SEf IES Construction Materials The BERMAD 700E valves are available in a variety of materials to ensure optimal suitability for a wide range of applications. For operation involving exposure to internal and/or external corrosive conditions, valves are constructed from corrosion-resistant materials making them suitable for use with seawater, brackish water, or corrosive environments such as seashore, petrochemical and other industrial facilities. Standard Configurations Item Number Description Firewater Valve 1 1 Cover Ductile Iron 12 2 Cover Bolt Z.C. Plated Steel 3 13 3 Cover Nut Z.C. Plated Steel 4 14 4 Separation Partition Ductile Iron 5 _ 15 5 Stud Z.C-.-Plated Steel 6 ., 6 Stud Nut Z.C. Plated Steel ------ 7 _ Valve_Body ................. Ductile Iron-------------- 7 16 - - -- - - - 17 8 Spring........... S.S.302 • --------- ---- ------------ -- ----------------- 8 9 Removable Seat S.S.304 --------------------------------------------------------------------- Seal NBR(Buna-N) 18 11 Upper Plug(6-20") Brass 12 Shaft Lock Nut S.S.303 -------- --------- - -- - - - ------------------ - -------------------------------- 13 Shaft Nut S.S.303 14 Diaphragm-Washers S.S.431 ___15____-Diaphragm----------------------NBR(Buna-N)_ __ 16 Bearing Screw S.S.303 - ---------------------------------- 17 Bearing Bronze 18 Shaft S.S. 303 19 Seal Disk S.S.431 SpEcifications Castings • Ductile Iron to ASTM A536 65-45-12(coated) •Cast Steel ASTM A216 Grade WCB(coated) PrESSurE Rating • Nickel Aluminum Bronze ASTM B148 C95800 •Stainless Steel 316 ASTM A351 Grade CF8M . . . • •Super Duplex ASTM A890 Grade 5A .. . pressure • Hastelloy C-276 - • psi bar Bolting: Flanged ANSI 816.42 #1 250 17.4 •Standard External Bolting:Zinc Plated Steel - g -------------------------------------- --------------------------------------- •Optional:S.S.316 to ASTM A320 Gr.B8F Flanged ANSI B16.42 #300RF- 400 28 ---------------------28 Internal Wetted Parts: Ductile Flanged ISO 7005-2 PN 16 235 16 -------------------------------------------------------------------------------------------------- ■Stainless Steel 303 ASTM A582 95B S30300A Iron Flanged ISO 7005-2 PN 25 365 25 -------------------------------------------------------------------------------------------------- •Stainless Steel 304 ASTM A743 Grade CF8 Grooved ANSI C606 300 400 25 •Stainless Steel 431 ASTM A743 Grade CA15M -- - - --------------------- -- Bronze ASTM B505 Grade C83600 Threaded BSP/NPT 300/PN25 400 25 ------------------------------------------------------------------------------------- ■ Internal Spring-S.S.302 Cast -Flanged ANSI 616.5 #1501RF 250 17.4 Optional Internal Wetted Parts: Steel Flanged ANSI 1316.5 300 # RF 2 -------- -----------400------------------ 8---------- •Stainless Steel 316 ASTM A351 Grade CF8M & Flanged ISO 7005-2 PN16 235 16 --------------------------------------------------------------------------------------------------- ■ Nickel Aluminum Bronze ASTM B148 C95800 Stainless Flanged ISO 7005-2 PN25 365 25 • Monel 400 Steel --------------------------------------------------------------------- ----------------------- • Hastelloy C-276 _ _Threaded BSP/NPT 300/PN25 400 25 •Internal Spring- Inconel Flanged ANSI B16.24 #150RF 250 17.4 Elastomers (Diaphragm &Seals) Ni-AI Flanged ANSI 1316.24 #300RF 400 28 - ---------------------------- -------- ----------------- ■ NBR, Polyamide fabric reinforced Nitrile(Buna-N), Bronze Flanged ISO 7005-2 PN 16 235 16 Temperature Rating 80°C 1 Flanged ISO 7005-2 1 PN25 365 25 ■ EPDM, Polyamide fabric reinforced Ethylene-Propylene, Note: Temperature Rating 90°C 2 1. Factory pressure testing:Each valve is tested at 1.6 of pressure rating. Coating 2. Water Temperature:0.5-50°C(33-122°F) • Electrostatic Powder Coating Polyester 3. Standard flange facing:Raised Face(RF),Serrated Finish. • High Built Epoxy Fusion-Bonded with UV Protection,Anti-Corrosion Flat Face(FF)flanges available on request. •Color: Fire Red to RAL 3002 Note:Internal&External coating applied on Ductile Iron or Cast Steel Castings only. BERMAD RrE ProtECtion -f -F FP 700E Flow & Hgdraulic Data 700 SEMES Flow Chart psi bar 15.0 1.0 12.5 ... 10.0 11/2" 2112 3„ 4" 6" 8„ 19 12' 14 16' I Os 7.5 0.5 U) 2" 0 m 5.0 N N i a 2.5 1.5 0.1 10 50 100 500 1,000 5,000 m3/h I I I 50 75 100 250 500 750 1,000 2,500 5,000 7,500 10,000 15,000 20,000 gpm Flow Properties Flow Rate DN 40-50 65 :e 1,00 150 200 250 300 350 gee Inch 11/211-f]ff 21/211 311 411 611 811 1011 1211 1411 1611 Kv-Y 50 55 115 200 460 8115 1,250 1,850 1,990 3,310 o. Cv-Y 58 64 133 230 530 940 1,440 2,140 2,300 3,820 K-Y 3.9 9.2 4.9 3.9 3.7 3.8 3.9 3.7 5.9 3.7 Leq-m,Y 10.3 33.4 21.6 23 37.5 53.9 70 85.6 159.9 112.7 Leq-feet,Y 33.8 109.5 70.8 75.6 123 176.9 229.5 280.8 524.5 369.6 Kv-A 55 61 127 220 506 897 1,375 2,035 2,189 3,641 Cv-A 64 70 146 250 580 1,040 1,590 2,350 2,530 4,210 K-A 3.2 7.6 4.0 3.2 3.1 3.1 3.2 3.1 4.9 3.0 Q Leq-m,A 8.5 27.6 17.8 19.0 37.0 44.6 57.8 70.7 132.1 93.1 Leq-feet,A 28 90.5 58.5 62.5 101.6 146.2 189.7 232 433.4 305.5 Valve flow coefficient, Kv or Cv Kv(Cv)=Q Gf Equivalent Pipe Length, Leq Leq=Lk•D Where: AP Where: Kv = Valve flow coefficient(flow in M3/h at 1 bar Diff. Press.) Leq= Equivalent nominal pipe length(m ;feet) Cv = Valve flow coefficient(flow in gpm at 1 psi Diff. Press.) Lk = Equivalent length coefficient for turbulent Q = Flow rate(m3/h ;gpm) flow in clean commercial steel pipe(SCH 40) AP = Differential pressure(bar; psi) D = Nominal pipe diameter(m;feet) Gf = Liquid specific gravity(Water=1.0) Note: The Leq values given are for general consideration only. Cv = 1.155 Kv Actual Leq may vary somewhat with each of the valve sizes. Flow resistance or Head loss coefficient, K=AH 2g Where: V2 3 K = Flow resistance or Head loss coefficient(dimensionless) AH = Head loss (m ;feet) V = Nominal size flow velocity(m/sec ;feet/sec.) g = Acceleration of gravity(9.81 m/sect; 32.18 feet/sect) MIT!in BERMAD RPE ProtECtion FP 700E DIMEnsions &WEights 700 SEf IES Metric Flanged L (mm) 10 205 222 250 320 415 500 605 725 733 990 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- co LGR (mm) N/A N/A N/A 250 320 415 500 N/A N/A N/A N/A T -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Z W (mm) 165 165 178 200 223 320 390 480 550 550 740 --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- O -R mm 78 83 95 1-00 1-15 1-43 172 204 242 268 300 Ln La (mm) 124 124 149 152 190 225 265 320 396 400 450 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- L ha (inch) 85 85 109 102 127 152 203 219 273 279 369 Hy (inch) 239 244 257 305 366 492 584 724 840 866 1,108 Z Ha (inch) 227 227 241 281 342 441 545 633 777 781 1,082 Q Weight Y (kg) 10.6 10.6 13 22 37 75 125 217 370 381 846 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Weight A (kg) 10 10 12 21.5 35 71 118 205 350 370 800 L (mm) 210 210 222 264 335 433 524 637 762 767 1,024 N W (mm) 165 165 185 - 207 250 320 390 --480 550 570 740 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 0- R ( ) 78 83 95 105 127 159 191 223 261 295 325 -------------------------------mm ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 0 La mm 124 124 149 159 200 234 277 336 415 419 467 Ln ) -------------- - -- --- ----- - --- ---------------------------------------------------------------------------------------------------- ---------------------- c ha (inch) 85 85 1.09 1-09 127 165 216 236 294 299 386 ° Hy (inch) 239 244 257 314 378 508 602 742 859 893 1,133 * ------ --- ------------------------------------------------------------------------------------------- Fn Ha (inch) 227 227 251 287 650 454 558 649 796 801 11099 Q Weight Y (kg) 12.2 12.2 15 25 43 85 146 245 410 434 900 ----------------------------------------------------------------------------------------------------------------------------------------------------------------- Weight A (kg) 11.5 11.5 1 3.5 23 41 81 138 233 390 421 855 a(') ( ) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ------------------------------------mm- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- b 1I (mm) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- • C(1) (mm) 3/ 3/ 3/4 3/4 3/4 2 2 2 2 2 2 ■ ------------------------------------------------------------------------------------------------------------- d(2)(optional) (mm) 3/4 3/4 11/2 11/2 2 2 2 2 2 2 2 Control Vol. (3)(Liter) 0.125 0.125 0.125 0.3 0.45 2.15 4.5 8.5 12.4 12.4 29.9 (1) (a), (b), (c)are NPT thread ports (2) (d)is BSPT threaded Optional drain port (3)(Control Volume)is Control Chamber Displacement Volume of liquid pushed when valve opens (4)LG for Grooved ends(see available sizes) b c b c Y Body TypE Angle Body TypE a a Hy Ha ha R CI d a L&LG = —La- c c O O O O 4 W - I1 I -- O O O b b BERMAD RrE ProtECtion -f! ov FP 400E DiMEnsions &WEights 0 Series English v r Flanged Size(inch) 11/2" 2" 21/2" 3" 4" 6" 8" 10" 12" 14" 16" L (inch) 81 8.1 8.3 9.8 12.6 16.3 19.7 23.8 28.5 28.9 39.0 co LG(4) (inch) N/A N/A N/A 9.8 12.6 16.3 19.7 B/A B/A B/A B/A T - ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Z W (inch) 6.1 6.1 7.0 7.9 8.8 12.6 15.4 18.9 21.7 21.7 29.1 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- O -R---------------------------(inch)--------3.1------------3.3------------3.7------------3.9------------4.5------------5.6------------6.8------------8.0----------9.5---------10.6---------11.8---- D La (inch) . . -------------------------------------------------4.9----------------49-------------------5.9 ---------- ------6.0 7.5 8.9-------------------------------------------------10---4--------- - ---12.6 15.6 15.7 17.7 ----------------------------------------------------------- 3 ha (inch) 3.3 3.3 4.3 4 5 6 8 8.6 10.7 11 14.5 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- * Hy (inch) 9.4 9.6 10.1 12 14.4 19.4 23 28.5 311 34.1 416 z Ha (inch) 8.9 8.9 9.9 11.1 13.5 17.4 21.5 24.9 30.6 30.7 42.6 Q Weight Y (1b) 23 23 29 49 82 165 276 478 816 840 1,865 - -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Weight A (Ib) 22 22 27 47 77 157 260 452 772 216 1,764 L (inch) 8.3 8.3 8.7 10.4 13.2 17 2.0.6 25.1 30 30.2 40.3 N W (inch) 6.5 6.5- 7.3 8.1 9.8 12.6-- 15.4 18.9 21.7 22.4 - 2.9.1 -R R (inch) 3.1 3.3 3.7--------4.1-------------5-----------6.3---------7.5--------8.8-------10.3---------11.6--------12.8 --------------------------------h)..-------------------------------------------------------------------------------------------------------------.5------------------------------------------------.------------------------ 0 La- - inch 4.9 4.9 5.9- 6.3 7.9 -----------------9.2 10.9- 13.2 16.3- 16.5 -18.4 � (inch) ------ o ha-------------------------inch)-------3.3----------3.3----------4.3----------4.3----------5.3----------6.5----------8.5----------9.3---------11.6--------11.8--------15.2---- co Hy (inch) 9.4 9.6 10.1 12.4 14.9 20 23.7 29.2 33.8 35.2 44.6 - ------ -------- ------ ------ ------- -------------------- ---- ----- - ---- ----- -------------- Fn Ha (inch) 8.9 8.9 9.9 11.3 13.8 17.9 22 25.6 31.3 31.5 43.3 Q Weight_Y (Ib) 27 27 33 55 95 187 322 540 904 957 1,984 ----- ------- ----- - - ---- -- ------ Weight A (1b) 25 25 30 51 90 179 304 514 860 928 1,88 a (inch) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ----- ---------------------------------------- -- - ----------------- - ----------------------------------------------------- b('> (inch) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- O C(1 (Inch) 3/4 3/4 3/ 3/ 3/4 2 2 2 2 2 2 '-----------------. -------------------------- d(2)(optional) (inch) 3/4 3/4 11/2 11/2 2 2 2 2 2 2 2 Control Vol.(3)(Gal.) 0.04 0.04 0.04 0.08 0.12 0.57 1.19 2.25 3.28 3.28 7.88 (1) (a), (b), (c)are NPT thread ports (2) (d)is BSPT threaded Optional drain port (3)(Control Volume)is Control Chamber Displacement Volume of liquid pushed when valve opens (4)LG for Grooved ends(see available sizes) Y Body Type b c Angle Body Type b c a a Hy Ha k ; N ha R =J!; a d a L&LG -c Oq� W - I � - O V V - � I -- li I 5 LI O b b BERMAD Rm ProtECtion FP 700E Installation, Operation - - 700 SENES Installation Proper operation of the 700E Deluge Valves depends In the SET position, the water pressure supplied through upon their trim being installed in accordance with the the priming line is trapped in the upper control chamber appropriate trim configuration. of the deluge valve by a check valve, and by the normally Notes: closed release device. • Wet pilot height should not exceed "Maximum The pressure trapped in the upper control chamber of the Elevation Above Valve" (see data for specific model). deluge valve presses the valve seal disk down, thereby • Any deviation in trim size or arrangement may sealing the valve and keeping the system piping dry. adversely affect the proper operation of the deluge Under conditions of FIRE, when the pressure is released valve. from the upper control chamber by the opening of the • All the pilot system devices, must be UL Listed and automatic releasing device or by manual release, the deluge valve opens and allows the inlet supply water to compatible with the particular deluge system. flow through the valve and into the system piping and Refer to current "UL Listed Fire Protection Equipment alarm devices. Directory". Warning: Whenever the handle of the Manual Emergency Warning: The deluge valve and trim must be installed Release is pulled, pressure is released from the upper only in areas where they will not be subject to freezing control chamber, the deluge valve will open, and water temperatures. will flow into system piping and alarm devices. Installation Instructions Electric 1. Allow enough room around the valve assembly for Pneumatic any adjustments and future maintenance. Hydraulic 2. Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Not flushing the line may result in the valve's becoming inoperable. 3. Install the valve in the pipeline so that the valve flow arrow appearing on the body casting is pointing in the desired direction. Ensure that the valve is positioned so that the actuator assembly can be easily removed for future maintenance. 4. Ensure that the Control Trim is mounted properly and I all other components are positioned correctly as per Valve Closed (Set Position) illustration. Line pressure applied to the upper control chamber 5. After installation in the main line, carefully inspect/ of the valve creates a superior force that moves the correct any damaged accessories, piping, tubing, or valve to the closed position and provides drip tight fittings. Ensure that there are no leaks. sealing. 6. Install the components comprising the Deluge Trim Electric Package in their proper positions in compliance with Pneumatic all instructions, drawings, and technical specifications Hydraulic describing the BERMAD Deluge Valve, according to the relevant illustration. 7. All additional accessories, although not packed together with the BERMAD Deluge Valve, must be installed as shown in the relevant P&ID and other illustrations. Operation Principle of Operation —0- The BERMAD 700E Deluge Valve (assembled with specific Valve Open (Operating Conditions) trim) is suitable for systems that include adequate 6 detecting and piping systems with open nozzles. The Releasing the pressure from the upper control deluge valve prevents water from entering system piping chamber to atmosphere or some other lower until required. The deluge valve is kept closed by pressure pressure zone causes the line pressure acting on the applied to the upper control chamber through a restricted seal disc to move the valve to the open position. priming line. BERMAD RrE ProtECtion _r _F FP 700E Installation, Operation &Maint- 700 SEI'IES Placing in Service/Resetting 5. The system should be checked weekly for "Normal The deluge valve and the control trim shall be Placed in Conditions". Service with accordance to the most recent IOM 6. Clean the priming strainer prior to any resetting of the procedures for the specific model. deluge valve. After all relevant instructions are performed, slowly open 7. The deluge valve must be activated at full flow at the supply-isolating valve and check that no water flows least annually. Take all necessary precautions to drain into the system. water and prevent damage in the area protected by The system is now operational and in stand-by mode. the system. 8. After about five years of operation, replacement of Maintenance diaphragm and other elastomers is recommended. Remove the actuator and disassemble it. Clean the Bermad Deluge Valves require no lubrication, no packing seat area from sediments, clean the control tubing tightening, and require a minimum of maintenance. entry holes, and install a new diaphragm and other Removing the System from Service elastomers in place. Warning: When taking a deluge system out of service, a fire patrol should be established in the system area. If Spare Parts automatic fire alarm signaling equipment is utilized, the 1. The Diaphragm and the Seals are the only spare parts proper authority should be notified that the system is needed for the main deluge valve, see attached being removed from service. The insuring body and "Valve Disassembly and Parts Breakdown" illustration. owner's representative should also be notified when the system is being taken out of service. 2. It is not recommended to store spare rubber parts for long periods (rubber in improper storage conditions can harden and crack). Removal Instructions 3. Contact your Bermad representative and order new 1. Shut off the main supply-isolating valve. rubber parts when required. 2. Close the priming line valve to the deluge valve control chamber. 3. Open all drain valves. 4. Release the water pressure from the control chamber of the deluge valve by pulling the manual emergency release. 5. Place "Fire Protection System Out of Service" signs in the area protected by the system. Inspection and Testing 1. Warning:Do not turn off the water supply to make repairs without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back in service. 2. Prior to turning off any valves or activating any alarms, notify local security guards and the central alarm station, if used, to avoid signaling a false alarm. 3. The deluge valve and the control trim shall be maintained with accordance to the most recent IOM procedures for the specific model. A periodic test schedule should be established also with accordance to the site conditions and owner regulations. 4. Take all additional measures as required by NFPA-25 "standard for the inspection, testing, and 7 maintenance of water-based fire protection systems". BERMAD Rm ProtECtion FP 700E Installation, Operation &M- - 700 SEMES Valve Disassembling Parts Breakdown Actuator Assembly 13 G Cover Plug _ (6"and up) O-Ring Bolt Eye i Nut Disk 9 0 o ° ° 0 0 Cover 0 0 Indicator Lock Nut Screw \ i � Nut - Diaphragm Washer Removable _ Seat J Spacer Disk O � 0 o Diaphragm ® O-Ring 0 0 0 o ° Diaphragm Washer 0 ® 0 0 0 0 0 Bearing Shaft Screw F �— Nut 0 0 Disk 1 0 I Y Body Type 0 Bearing Assembly Separation i Partition o 0 c Seal Disk 0 o C� Assembly 0 0 Bolt Nut ®— O-Ring 0 0 Seal Stud Disk 0 Spring o � 0 Seal o® 0 S — ( –Seal 0 0 Disk Wash. 8 0 Nut 0 ®_ Locking Screw Angle Body Type Screw bErmadfiPE @bErmad.com www.bErmad.com The information herein is subject to change without notice.BERMAD shall not be held liable for any errors.All rights reserved. ©Copyright by BERMAD. PT7PE04-DATA ES-F-860L SPECIFICATION SHEET 7/e MasterSeries® 860alS� Reduced Pressure Zone Assemblies Size: 21/2" - 10" (65mm - 250mm) The FEBCO Master Series°860 Reduced Pressure Zone Assemblies are designed for health hazard applications. End connections—Flanged ANSI B16.1 Class 125 Pressure—Temperature Max.Working Pressure: 175psi(12.1 bar) HydrostaticTest Press: 350psi(24.1 bar) Temperature Range: 32°F to 140°F(0°C to 60°C) MODEL 860 REDUCED PRESSURE ASSEMBLY Materials Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external Capacity AWWA C550 Shutoff Valves: NRS and OS&Y resilient wedge gate kPa si valves AWWA C509 P 21/2'&3"(65mm&80mm) 138 20 Trim: Bronze Elastomer Discs: EPDM o 103 15 21h" Spring: Stainless steel 3" = ss 10 Clamp: AWWA C606(10"only,250mm) 34 5 Approvals—Standards 0 160 240 32 400 gpm pp 0 300 4 606 910 1211 1 15201pm • ANSI/AWWA(C511)-21/2"-10" • Approved by the Foundation for Cross-connection Control and Hydraulic kPa psi Research at the University of Southern California.-21/2"-8"(65-200mm) 138 20 4"&6"(100mm&150mm) ��pSSIFjFo H55E ® C UL US FM o 103 15 Approved 1013 B64.4 21/2"-B" 21/2"-8" = 69 10 21/2"-10" 21/2"-8" 65-200mm 65-200mm 4" 65-250mm 65-200mm 34 5 0 400 800 1200 1600 2000 gpm Typical Installation 0 1520 3040 4540 6060 76001pm kPa psi g'&10"(200mm&250mm) Model 860/Typical Installation 138 20 0 103 15 101' 0 = 69 10 34 5 0 1000 2000 3000 4000 5000 gpm 0 3800 7600 11400 15140 19000 PM Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative FEBCO product specifications in U.S.customary units and metric are approximate and are provided for reference only. For precise mea- surements,please contact FEBCO. FEBCO reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subse- quently sold. Series 860 / Materials of Construction ITEM DESCRIPTION MATERIAL 1 Body A536 GR 6545-12 1.1 Pipe Plug Galy.Stl. 1.2 Bushing(2112'4 Only) Brass 41.1 2.1 a 2 Cover A536 GR 65-45-12 40 9 (D 2.1 O-Ring EPDM ASTM D2000 13 '` 10 2.2 Cap Screw Plated Steel s0 62 s 2.3 Hex Nut Plated Steel a 4 41 15 3 Seat Ring 8584 Alloy C83600 s � 4. s 11.1 D 3.1 Gasket EPDM ASTM D2000 s 17 7 2.1 3.2 Socket Head Screw 18-8-SS 3.3 Washer 304 SS 3.4 Elastic Stop Nut 18-8-SS 4 Arm B584 Alloy C83600 25 24.1 24 4.1 Bushing-Swing Pin Acetal Resin O O 29 31 31.1 4.2 Swing Pin 304 SS 5 Retaining Clip 302 SS zs 39 5.1 Retaining Clip 302 SS F 24. 24.1 5 6 Check Disk EPDM Coated GR,45 39 Ductile Iron with -00 41 42 1.2 CO.-,40 30.1 35.2 35.1 3.1 3 10.1 12 1 1.1 14 19 18.1 A276 type 304SS stem 20 34.1 7 Load Pin B 150 Alloy C61300 28.1 B Lwr Spring Retnr B584 Alloy 083600 9 Spring Stem 304 SS zo.lzo.z 37 _ 9.1 Elastic Stop Jam Nut 18-8SS 27 23 E 10 Spring A313 Type 631 SS 22 39.1 21 29 28.2 30 32 24 24.1 25 33 10.1 Spring 2nd Check A313 Type 631 SS 10.2 Spring Shim 2nd Check Acetal Resin 20.1 20.2 11 Spring Guide B130 Alloy C22000 12 Upr Spring Retnr B584 Alloy C83600 B 12.1 Bushing-Spr.Stem Acetal Resin ___________________A------------------------------------------1 13 Pivot Bearing B585 Alloy C83600 14 Flange Gasket Rubber/Fabric 15 Bearing Socket Acetal Resin 16 Hex Jam Nut 18-8 SS Top View 17 Washer 302 SS 18 Flange Nut Plated Steel - - 18.1 Flange Nut Plated Steel G / C. C / C C� 20 R.V.Cover B584 Alloy C83600 O CC CC O 20.1 Bleed Screw HD SS C, C• C, 21 Gasket HDPE 21 H C, C, 21 R.V.Body B584 Alloy 083600 22 Cover Bolt 18-8 SS 23 Elbow A536 GR 65-45-12 24 RV Mtg Bolt Plated Steel 24.1 Washer Plated Steel 25 RV Mtg Nut Plated Steel 26 Gasket EPDM 27 Lrg.Diaphragm NitrileASTM D2000 28 Button A240 304 SS Dimensions-Weight 28.1 Flow Washer Acetal Resin 29 RV Spring A3137ype 302 SS Size:21/z"-10"(65-80mm) 30 RV Stem Acetal Resin SIZEIDN) DIMENSIONS w�r.}�T 31 Main Guide FDA EPIoyC83600 31.1 Main Guide O-Ring FDA EPDM A B C D E F G H NRS OS&Y 32 Seat Disc EPDM AST D2000 33 Lower Guide Acetal Resin in. mm in. mm in. mm in. mm in, mm in, mm in. mm in. nn in. mm lbs. kgs. lbs. kgs. 34 Seat Ring 8584 Alloy C83600 21/2 65 403/4 1035 251/2 648 125/8 321 10 254 12'/8 327 10 254 4/2 114 71/8 181 219 99 223 101.2 34.1 O-ring FDA EPDM 3 80 498 1064 25% 651 127/8 327 10 254 13 330 10 254 41/2 114 73/8 187 231 105 233 105.7 35.1 O-Ring EPDM ASTM D2000 4 100 461/4 1175 28 711 143/8 365 101/8 257 151/8 384 101/8 257 5/2 140 81/8 206 317 144 334 151.5 35.2 Extension Acetal Resin 37 Sm.Diaphragm NitrileASTM D2000 6 150 56 1422 343/4 883 187/8 479 123/4 324 203/4 527 111/8 283 61/2 165 97/8 251 481 218 516 234.1 38 Retainer 8584 Alloy C83600 8 200 65 1651 413/4 1061 231/2 570 15%397 267/8 683 121/4 311 7 178 111/8 283 734 333 796 361.1 38.1 Slip Ring Acetal Resin 39 Flow Washer Acetal Resin 10 250 72%1845 463/8 1178 271/2 699 15%397 281/4 718 123/8 314 9 229 123/8 314 946 429 1008 457.2 40 Ball Valve 8584 Alloy C84400 41 Nipple Brass Note:Dimensions shown are nominal.Allowances must be made for normal manufacturing tolerances. 41.1 Nipple Brass Note:The a drain is not designed to catch the maximum discharge os- 412 Nipple Brass gap g g p 42 Gate Valve(N RS) AW WA 0509 sible from the relief valve.The installation of FEBCO air gap with the drain 60 Identification Plate B36 Alloy 026000 line terminating above a floor drain will handle any normal discharge or nui- 62 Drive Screw Stainless Steel sance spitting through the relief valve.However,floor drain size may need 70 Clamp AWWA C606(10"Only) to be designed to prevent water damage caused by a catastrophic failure condition.Do not reduce the size of the drain line from the air gap fitting. FEBCO . 9001-2008 ® I CERTIFIED A Watts Water Technologies Company USA: Fresno,CA Tel:(559)441-5300•Fax:(559)441-5301•www.FEBCOonline.com Canada: Burlington,ON•Tel:(905)332-4090•Fax:(905)332-7068•www.FEBCOonline.ca ES-F-860L 1119 0 2011 FEBCO www.nibco.com AHEAD OF • ODWff Water Tubecont i nued DIMENSIONAL DATA ... , ; TYFE"M° Hard Drawn Chly 20ft.(6.1m)Straight Lengths Lbage. For gc e al purpose pl umbi ng,heati ng and drainage installations. Tolerances Hard Dawn (Hard Drawn Qtly) CUtside TubingCID Nominal Wed Weight Bursting Safe Work ng Nordnal Llarreter Zhidvaess Per Foot FtessureA FtessureB Water Tube Min. Max sar(In Inches) Inch (mm) Ind, (mm) Ind, (mm) Ind, (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) NA N/A NVA NA NA NA NA INYA 318 0300 (1270) 0.497 (1262) 0.501 (1273) Q025 (0.64) 0.145 (0.07) NSA RYA 855 (59) 1/2 0.625 (15.88) 0.671' (15.80) 0.626 (15.90) Q028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 518 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) RYA IVA NA NIA NA RYA NA NA 314 0.875 (72.23) 0.872 (22.15) 0.876 X2.25) 032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 018.63) Q035 (0.89) 0.465 (0.21) 3865 (266) 506 05) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (Z67) 507 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) WA9 (1.24) 0.940 (0.43) 3560 (245) 497 (34) 2 2125 (53.98) 2121 (53.87) 2127 (54.03) Q058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2625 (66.68) 2621 (66.57) 2627 (66.73) Q065 (1.65) 2030 (0.92) 2800 (193) 411 (28) 3 3125 (79.38) 3121 (7927) 3127 (79.43) 0072 (1.83) 2680 (1.22) 2665 (184) 380 (26) 31/2 3625 (92.08) 3621 (91.97) 3.627 (9213) 0.083 (211) 3580 (1.62) RYA NA 378 (16) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) Q095 (241) 4.660 (211) 2215 (153) 377 (Z6) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) x109 (277) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (310) 8.920 (4.05) 200D (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (1.48) 2186 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) NA NA 344 (24) 12 12125 (307.98) 12119 (307.82) 12127 (308.03) 0.254 (6.45) 36.700 (16.65) NA N/A 345 (24) Note:Infarrretion and data contained i n these da ts,as taken from ASTM Specifi cations B 88. Rated irternal pressure for copper water tube based on the strength d the tube oicne aid applicableto systems using suitable media ical joints. "Based cn actual laboratory test data presided by 03W Deveioprrent Association,Inc 6 Based upon 150°F(65.6oQ with an allavable stress of 9500 psi(668k%). U.S custcrnery units i n tfi s doaarrent are the standard;the metric units are VuA ded for reference oiy.the\riues stated in each system are not exact equivalents NIBMINC WCRDHB DQ1ARRT6- 1516MICD_B3L WST.• B104Wf,IN46516-}740• USA- RA 1.800.234.0227 TM I SBRvtCEB A-t 1.888.446.4226• FAX 1.800.234.0557• INTB3JAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 wwwribco.00rn CATALOG C-CF 0404 AREAD OF • Wm 3 M ±i+ /F Copper Fitti ngs NIBCM AHEAD OF THE FLOW a mmco, N IBCO flow-control solutions are everywhere you look, including on our website. We offer a wide range of metal and plastic valves • fittings that keep residential, • • inclustrial operations flowing smoothly throughout • • br7i�U r�*r I�BsI voe rrtr� err you need it, �, I P—Partner oacftrtnercow JH3C_ 0 aid 7! fiiffael � fl li9 IF.• a.eA r T MW Produft A4 �.IUtlaeAwicn... • • • • -ly fr94:fFi g#eull lrOK71>•a,G++ 3r a TPnuHY{r.7 �y y VV .aeY4YR{ 4+uelA+lr.t p>ai lip4q[gft ej*&— __ __ vwor 4+iaA4A Alrr►Kµ _ – _ � • h a Es The"New Products" page is a The"Fittings" Homepage at continuoudy updated showcase wwwniboo.com provides easy _ s_ for new products by N IBCO. access to valuable reference tools. i fly, * Current highlights include: * Key information includes: ® Compact Economy Ball valves , ® Repackaged Pneumatic Ball Valves Rice sheets(FDF& Excel format) Circuit Balancing valves —also accessible from home page ® Ranged Butterfly valves Downloadable catalogs(FDFformat) Bronze Ball valve Line Extension R-oduct drill-down capabilities to categories _ Fink® copper fittings for R7(applications W rot Copper& Cast Bronze Fittings • Ist Rghte hot-water circulation device ABS& PVC Drain, Waste, &vent • Carbon/ Stainless Steel Ball valves PVC Schedule 40 Fittings&valves • Socket Fuson Equipment CP✓C CTS Fittings • TruConne&fittings for ChemAire� NIBMINCwCRDF64DaARfEF;S• 1516MIDCU33_R(Sr.• BJB>Rr,IN46516-4740. 1),54• R-t1.800234.0227 TM i SBZvICE]S R-11.888.446.4226• FAx 1.800.336.4226• IMBaJ�lKiALCFRCE R-t+1.574.295.3221• FAX-+1.574295.3455 wwwhbm.mm NIBCCY www.nibco.com AHEAD OF • 0- able of Contents Cast Copper Alloy flared Fittings ..........................22-24 Copper Insert Fittings for FEN ink. .........................2527 Copper-Insert Fittings for Fblybutylene .....................2 8-29 Engi need rig Data.......................................41-84 Frequently-Asked Cu estions.................................90 Installation Instructions..................................85-89 Nurraical Index ..........................................92 Spedfications .............................................4 Warranty................................................91 Wrot&Cast GM/Fittings ...............................3040 Wrot&Cost R-essure Rttirgs .............................5-21 isosapl:zaoo themaVa urirgplatsat 33ahGe libll$W, a ats Daft,\1 Nafix -,,TX and fbjaxsa,Mecoom3Vactve productsrrdaaQdity Mauls,Systenoorfomirg totheo.rret revisarof ISD9001 IrtEmatimal aaxiaris NIBOJING WCRDFEADCLART9T• 1516MIU183-WSr• BJ44gU,IN465164740• US4• R-t 1.800.234.0227 TEH SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• IN193VAl1CNALSERACE R-t+1.574.295.3221• FAX-+1.574295.3455 wwwAboo.00m www.nibco.com AHEAD OF • Specifications ■ ■ ■ All of the advantages found in copper as a rretal have been capitalized to the utmost in the manufacture of NIBODFittings. Because of the accuracy of oonstruction and design,copper pluming is more efficient and less expensive. NIBODm3nufacturesninegeneral types offittirigs:Wrot FTessure;Cost Ressure;Wrot Drainage;Cast Drainage; Ranges; Rared Tube;Threaded Bronze; Insert Rttirigs for RDC Barbed Insert Fittings for Rlybutyleae. Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLCNAND KNISH—NIBOD Rtti rigs are made from highest qua]ity raw materials avai Iable—Cost Rtti rigs are made from Copper Alloy 084400 which oonsists of 81%Copper,7%Lead,31/o Tin,and 91/o Zinc per ASTM Specification B584.Wrot Copper Rtti rigs are made from cmTTffaAIy pure copper mill products per ASTIVT Specifications B75 Alloy 012200. NIB00fittirlgs are produced to nmet requirenE is of applicable standards wherever practicable. NIB00brand wrot and cast fittings are manufactured in the U.S.A.and Mexico.The manufacturing plants at South Glen Falls, NY Stuarts Draft,VA, Nacogdoches,TXand Peynosa, Mexico are registered to IS09002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper-Tube Rtti rigs. WFuscl-DBRJQNT RTTINGS—"Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and waiaaanship shall be in accordance with ASMHANSI B16.22;Wrought Copper and Copper Alloy Solder Joint Ressure Rttirigs." 2. The dinEnsional,material and woiarenship shall dimensions of Federal Specifications WW-F-406 or meet the requirements of MSS SP-104,-Wrought ASMEStd. B16.24. Copper Solder Joint Ressure Fittings." CLASS 125—Material,waiananship and 3. The di rrerri onal,mated al and wor1gTanship of dimerdons of flanges shall be in accordance with F-12"copper fittings shall meet the requireaaoTts MSS SR106. of MSSSP-109"WeldedFabricated CqW Solder Joint Ffessure Fittings." CA�f h-FTAD®RT TI NC S- "Cost Bonze Threaded Fitti ngs shal l be i n accordance 4. CertifiedtoANSI/NSF61. with ANSI/ASMEB16.15." CAST CXTERALLC Y SC1DER J O NT FITTINGS— FGLYBUTYL NE CX3::RR INSERT TYFE UALVESS AND "Cast Copper AI I oy Solder Joint Fittings shall be in FITTINGS—"Wrot Copper-Insert Fittings shall be aocordanoe with ANSI Std.B16.18." manufactured per the following specifications: WFUFDRAINA(URTTINGS—"Wrot Drainage MSSSP-103 orASTM F1380." Fittings shall be in accordance with ASMFIANSI Std. NIBODO)pper Tube Fittings are all produced to above B16.29." Standards.To simplify,write your specifications to CAST 0J::RRALLC Y SCLDER J d NT DRAT NACU read:"Copper Tube Fittings to be in accordance with FITTINGS—"Cast Copper Alloy Side-Joint Drainage specifications as outlined in NIB00Catalog c cf-0602." RttingsshalI be i n accordance with ASME Std. WROTC3:FERME01CALMEDCAL GAS SYSrEM B16.23." 03\AFCNEVTS—Wrot copper fittirgs that are to be CAST G)CFFERALLCN RAFT TUBE RTTI NGS—"Cost i nstal I ed i n medi cal gas appl i cat i ons shat I be prepared Copper Alloy Rared Tube Fittings shall be in a000r- in accordance with NFFA 99, Health Core Facilities Gras dance with ASMHANSI Std. B16.26. and Vacuum Systems and the Compressed C?s Association, Pan-phl et GM. Pad<agi ng shall be CAST 031:RRALLCN RANCIB AND RANGE] adequately protective and include labeling that FITTINGS— identifies the prepare-and states that the product has G ASS 150—Cast Copper AI I oy Ranges and been d eaned and bagged for oxygen or med gas Ranged Rttirigs shall meet the requirements of sere. MSS SP-106 andlor the woivranship and For technical info-rration and dimensions refer to the enginee ring section contained in this catalog. NIBOJING WC}aDHEN)C.WRT9'S• 1516MIDDL83-R(ST.• RA-PRr,IN46516-4740• USA- R-t 1.800.234.0227 TKHSERv10E5R-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAX+1.574.205.3455 www.niboaoomm NIBCCY www.nibco.com AHEAD OF • 04 Wrot and Cast Pressure Fittings 600 Seri es—Wrot 700 Seri es—Cast Adapters ...............................................6-8 Air CharTbers .............................................8 BulWlead Rttings ..........................................8 Bushings .................................................8 Caps ....................................................9 C buplings..............................................9-11 Crosses .................................................11 BbNVs ............................................... 11-15 Fitting Fbduaers ..........................................15 Ranges .............................................. 15-16 Rugs ...................................................16 Fbturn Bends ............................................16 Straps ..................................................16 Tees ................................................. 16-20 Traps ...................................................20 Unions..................................................21 Venturi ..................................................21 Ys .....................................................21 � * o kS09003:20 R9 Therranfaduirgpatsat SathaetisFalls,NY, 3uatSID#t,VA Nxcgdod>°s,TX andFtytx McAoorrerxfalue pD lasuxleraQiality Mavgamt 9�stemoafar irg tothearrat rWsicnof 1839001 Irteraicrel Start hds NI9C D I NG WQaD FEADQ.14R1 F S• 1516 MI DDLffiLRY ST.• 934-WAS IN 465161A40• USA• F}t 1.800.234.0227 TEI-iSERACESR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAflCNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.nboo.mm www.nibco.com AHEAD OF • ADAPTERS EM EE - 603 703 703-2 Adapter Cx F-Wrot Adapter Cx F-Cast Fitting Adapter Rg x F-Cast INCHES . E 1/8 0.03 13/32 1/4x1/2 0.13 27/32 1/2x1/4 0.11 17/32 1/8x1/4 0.03 1/2 1/2x1 0.30 1 3/4x1/2 0.12 19/16 1/4 0.03 5/8 3/4x11/4 0.55 11/8 1x3/4 0.38 131/32 1/4x3/8 0.05 21/32 3(4x3/8 0.17 3/4 1 x1/2 0.15 17/16 3/8 0.04 11/16 1 x 1 1/2 0.68 13/32 21/2 1.65 215/16 3/8x1/2 0.09 29/32 11/4x1 0.27 31/32 3 2.47 31/4 3/8x1/4 0.03 9/16 11/4x3/4 0.29 3/4 1/2 0.09 77/32 11/2x2 0.78 11/32 1/2x3/4 0.14 1 11/2x1 0.37 25/32 1/2x3(8 0.04 17/32 11/2x11/4 0.47 11/4 _ 1/2x1/4 0.05 1/2 2x11/4 0.76 77/32 Ll 518x3/4 0.12 29/32 21/2 1.62 13/8 5(8x1/2 0.11 3/4 3 2.34 11/2 lw 314 0.15 29/32 4 4.05 19/16 3/4x 1 0.21 11/8 A 3/4x1/2 0.10 5/8 1 0.24 31/32 703-5 SpExjal 1 x 11/4 0.28 17/32 Drop Adapter Cx F-Cast 1 x314 0.19 2s/32 -_• 1 x 1/2 0.24 5/8 NCM.SIZE NEFWT./LBS. INCHEB 11/4 0.33 13/32 �� I 1/2 0.16 3/4 1 1/4x 11/2 0.40 11/4 /�J �II 3/4 0.24 31/32 11/4 x 1 0.27 31/32 603-2 11/2 0.44 11/8 Fitting Adapter Rg x F-Wrot 11/2x2 0.50 11/32 APPROX 2 0.63 13/32 • INCHES- 2x11/2 0.74 13/16 1/4 0.03 13/32 21/2 1.13 - 3/8 0.06 13/16 3 1.94 - 1/2 0.09 17/16 1/2x3/8 0.05 11/4 3/4 0.13 111/16 A 1 0.27 2/32 703-56 11/4 0.31 21/8 Drop Adapter Cx F-Cast 11/2 0.43 25(16 2 0.61 217/32 APPROX NCM.SIZE • 1/2 0.15 3/4 03-&Jt price sheet for Made to Oder items and for rrinirrumorder quantities. NIBMINC VVCRD HE DQ14Rf@S• 1516 MICaEBLR(SL• RK4NRr,IN 46516-4740• USA• R-t 1.800234.0717 TEH SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNAL SERACE R-t+1.574.295.3221• FAX+1.574295.3455 www.riboo.00m NIBCCY www.nibco.com AHEAD OF • 04 ADAPTERS continued A 604 704 704-H Adapter Cx M -Wrot Adapter Cx M-Cast Hose Adapter Cx Hose-Cast NCM.SIZE NEFWT./LBS. INCHES NOM.SIZE NEFWT./LBS. . ES NCM.SIZE NETWT./LBS. INCHES 1/8x1/4 0.03 7/16 3/4x11/2 0.60 117/32 1/2 0.09 9/32 1/4 0.03 23/32 3/4x11/4 0.38 17/32 NOTERts'/2:"/a'andW'carde Hose. 3/8 0.04 15/32 3/4x3/8 0.19 13/16 3/8x314 0.15 15/16 1x2 1.15 - 3/8x1/2 0.09 1 1 x1 1/2 0.64 29/32 1/2 0.07 5/8 11/4x2 0.88 19/32 1/2x1 0.25 11/2 11/4x3/4 0.30 31/32 1/2x3/4 0.15 13/16 1 1/2x2 0.77 11/8 e , 1/2x3/8 0.05 19/32 2x21/2 1.57 115/32 1/2x1/4 0.07 5/8 2x11/2 0.71 11/8 604^2 5/8x3/4 0.16 11/8 2x11/4 1.08 - 5/8x1/2 0.08 3/4 21/2 1.48 121/32 Fitting Adapter Fig x M-Wrot 3/4 0.14 13/16 21/2x2 1.83 111/16 APPROX • 3/4x1 0.26 17/16 3 1.96 11/2 • 3/4x1/2 0.10 27/32 4 3.66 111/16 1/8 0.02 11/8 1 0.21 31/32 5 8.60 25/8 3/8 0.04 11/4 1 x1 1/2 0.54 29/32 6 10.73 2 1/2 0.09 115/32 1 x1 1/4 0.38 11/2 1/2x3/4 0.16 113/16 1 x3/4 0.18 29/32 1/2x3/8 0.04 111/32 1 x1/2 0.18 31/32 3/4 0.17 115/16 11/4 0.35 '5/16 1 0.25 21/4 11/4x11/2 0.51 119/32 11/4x 1 0.27 151 32 11/2 0.44 31/32 11/2x2 0.81 11/8 B 1 1/2x 11/4 0.38 13/16 s 11/2x1 0.37 13/32 704E 2 0.81 13/32 Rush Adapter Cx M-Cast 2x11/2 0.64 11/8 --•O_ • 704-2 21/2 1.48 121/32 • • 3 1.69 - 1/2 0.03 9/16 Fitting Adapter Rg x M-Cast 3/4 0.03 19/32 •--• .INCHES 3/4 x 1 0.27 131/32 3/4x1/2 0.12 123/32 1 x3/4 0.24 115/16 11/4 0.43 227/32 11/2 0.54 213/32 2 0.89 23/4 21/2 1.55 33/8 Consult price sheet for Made to Order iterrs and 3 221 323/32 for n i ni rrum order quantities. NIBDJINGWCRDFEADCLARTUS• 1516MIDDL83JWST• a1+IARrIN465164740• L1S4• R-t1.800.234.0227 TEHSERACESPFt1.888.446.4226• FAx1.800.234.0557• INTB+Al1CNALSERACER-t+1.574.295.3221• FAX-+1.574.295.3455 wwwAboo.aom www.nibco.com AHEAD OF • ADAPTERS continued BULKHEAD BUSHI NGS FI TTI N GS 7042-H " 618 Hose Adapter Ftg x Hose-Cast 750 Rush Bushing Ftg x C-Wrot Bul khead Fitting Cx C-Cast ,---• INCHES NOM.SIZE NEFVVT./LBS. 3/4 Fx 1/2 H 0.16 15/a • i • • ES 1/4 x 1/8 0.01 - 1/16 NOTE Fits 1/z^5/8'an W'Garden Hose. 1/2 0.48 11/4 1 3/8 x 1/4 0.01 1/16 3/4 0.77 19/32 11/4 1/2x3/8 0.02 3/32 1 1.30 11/2 15/8 1/2x1/4 0.04 1/4 Al R CHAM BERS 11/2 2.87 11/2 23/8 6/8x1/2 0.03 1/16 2 3.82 21/32 25/8 3/4x5/8 0.22 3/16 314x1/2 0.08 3/32 3/4x3/8 0.11 7/16 1 x3/4 0.12 1/8 1 x 1/2 0.22 15/32 - - - " 1 1/4x1 0.17 3/32 e 11/2x11/4 0.22 5/32 619 L -A- 66 2x11/2 0.66 1/8 �A Air Chamber Ftg.-Wrot 754-3 NOM.SIZE NEFWT./LBS. INCHES' _.. 1/2x6 0.21 1 6 Bulkhead Fitting Cx F-Cast 1/2x12 0.41 1 12 APPROX DIM.A DIM.- 1/2x14 0.78 11/8 14 NCM.SIZE • • 3/4x12 0.40 1 12 1/2 0.48 115/16 1 3/4 0.79 21/16 11/4 618-3 1 1.43 215/32 15/8 Rush Bushing Ftg x F-Wrot APPROK NOM.SIZE • 1/2x1/8 0.03 9/16 1/2x1/4 0.03 9/16 ► - - e 620-L Ai r Chamber or Stub-Qrt A Ftg-Wrot As AirOmnter,justsd der one ja rt.When used as Stub-O-d,sir-0y pressure test systemt hen out 754-4 off stub-out(save pieoe for future use)and i nstal I 718-3 valve or fixture. Bulldlead Fitting Cx M-Cast R ush Bushi ng Ftg x F-Cast APPFUX DIM.L NCM.SIZE NETWT./LBS. INCHES INCHES APPROK DIM.B NOM.SIZE • 1 • . • 1/2 0.40 1332 1 1/2x6 0.14 6 3/4 0.79 25/32 11/4 314x3/8 0.06 131/32 1/2x8 0.19 8 1x1/2 0.13 31/32 1/2x10 0.24 10 11/4x3/4 0.18 11/32 1/2x12 0.28 12 11/2x1 0.25 15/32 3/4x12 0.46 12 GbrWt pn ce sheet for Made to C rder iterrs and for rri ni mam order quantiti es. NIB00INCWCR.DFEADQ14RTEM- 1516MICD-BBLWST.• aA-PffIN46516-1740• LISA- 19141.806234.0227 TEH SERAC1B Rt 1.888.446.4226- FAx 1.800.234.0557• IMffdVA-na PLSERACE R-t+1.574.295.3221• FAX+1.574295.3455 www.rliboo.com NIBCCY www.nibco.com AHEAD OF • 04 CAPS COUPLI NGS APPROX. DIM.A NOM.SIZE NEFWT/LBS. INCHES -- } 3x21/2 0.98 1/2 3x2 1.06 15/16 � �� I 3x11/2 0.92 11/32 IN f 31/2x3 1.52 1/2 6W 4x31/2 212 19/32 617 Fedua ng C uo i ng Cx C-Wrot 4x3 1.92 2132 Tube 03p C-Wrot _ 4x21/2 1.77 1 _ _ �- • 4x2 1.92 11/4 • 5x4 3.50 331/32 NOV. � • 1/8x3/160D. 0.01 5/32 1/8 0.01 - 1/32 5/160D.x1/8 0.01 3/16 5x3 3.18 115/32 1/4 0.01 3/32 1/4x5/160D. 0.01 3/16 5x21/2 3.50 13/16 318 0.01 3/32 1/4x1/8 0.01 3/16 5x2 3.09 21/32 1/2 0.02 3/32 318x1/4 0.02 3/16 6x5 5.70 11/8 518 0.03 1/8 318x5/160D. 0.01 y4 6x4 5.24 11/2 314 0.04 1/8 318x1/8 0.01 1/4 6x3 5.04 2 1 ON 5/32 1/2x318 0.03 3/16 6x21/2 5.13 21/4 11/4 0.10 3/32 1/2x1/4 0.02 1/4 6x2 4.89 21/2 11/2 0.16 1/8 1/2x1/8 0.03 1y- 8x6 13.06 119/32 2 0.27 5/32 518x1/2 0.05 3/16 8x4 1222 219/32 21/2 0.50 7/32 518x318 0.04 11/- 8x3 11.79 33/32 3 0.78 7/32 518x1/4 0.03 13/_ 8x21/2 1264 33/8 4 1.66 1/4 314x518 0.07 3/16 314x1/2 0.06 9/82 314x318 0.06 3/8 314x1/4 0.05 11/32 1 x314 0.11 11/32 1X518 0.09 3/8 ��-A N 1 x 1/2 0.10 11/32 1 X318 0.10 13/32 600-FMS 717 1 1/4x1 0.16 5/16 Coupling With Fblled Tube Stop Tube Ca C-Cast 11/4 x 3(4 0.18 17/32 Cx C-Wrot Cap 11/4x5(8 0.18 5/8 .,-• APPROX DIM,N 11/4x1/2 0.14 7/16 NOM.SIZE NETVVT./LBS. INCHES • . INCHES 11/2x11/4 0.23 5/16 1/80D. 0.01 1116 5 5.48 7/16 11/2x1 0.22 9/16 6 9.07 17/32 3(16 OD 0.01 3/32 11/2x314 0.20 3/8 1/8 0.01 1/16 11/2x1/2 0.19 1/2 5(160D 0.01 3/32 2x11/2 0.41 9/16 1/4 0.01 1/16 2x11/4 0.35 11/16 318 0.01 3/32 2x1 0.37 7/16 1/2 0.03 3/32 2X314 0.34 17/82 5(8 0.04 3/32 2 x 1/2 0.35 23/32 3✓4 0.06 3/32 21/2x2 0.59 9/16 7/8 0.09 3/32 717-D 21/2x11/2 0.65 11/16 1 0.11 3/32 Drai n Cap-Cast 21/2 x 1 1/4 0.65 13/16 11/4 0.16 1/8 21/2x1 0.73 29/32 11/2 0.23 1/8 NOM.SIZE • E 03trEES••• 2 0.41 1/8 1/2 0.06 21/32 21/2 0.65 1/8 3 0.93 1/8 31/2 1.45 5/32 4 1.93 7/32 Consult price sheet for Made to Order itam and for ni ni rrum order quantities. NIBD)ING WCR.D FEADCLART9T• 1516 MIDDLB3-W Sr.• BJ44NU IN 465164740• LSA• R-t 1.800.234.0227 TB ISERACESPH 1.888.446.4226• FAX 1.800.234.0557• INTB+A-11CNALSERACER-t+1.574.295.3221• FAX-+1.574295.3455 www.riiboo.corn www.nibco.com AHEAD OF • COUPLINGS continued E -3 E3 600-DS 601 701-D Coupling with Dimpled Tube Stop Coup)i ng without Stop Drai n Coupl i ng Cx C-Cast Cx C-Wrot Cx C-Wrot APPROX,APP-OX, • NICM.SIZE NErVVT./LBS. INCHES APPROX DIM.A APPROX NOM.SIZE • • . • 1/2 0.08 1/4 3/160D. 0.01 3/32 1/4 0.01 11/16 3/4 0.14 1/4 1/8 0.01 1/16 3/8 0.01 2/32 1 0.22 1/4 51160D. 0.01 3/32 1/2 0.03 1 1/4 0.01 1/16 5/8 0.04 111/32 318 0.01 3/32 3/4 0.06 119/32 1/2 0.03 3/32 1 0.11 129/32 58 0.04 3/32 11/4 0.16 21/16 3/4 0.06 3/32 11/2 0.23 26/16 A I� 7/8 0.09 3/32 2 0.41 213/16 1 0.11 3/32 21/2 0.64 215/16 11/4 0.16 1/8 3 0.86 35/16 702 11/2 0.23 1/8 31/2 1.40 6 45/1 IbcentricGouplingCxC-Gast 2 0.41 1/s 4 1.84 45/16 21/2 0.65 1/8 5 3.50 55/16 -O ' • . . INCHES 3 0.93 1/8 6 5.60 63/16 3/4x1/2 0.10 17/32 31/2 1.45 5/32 8 13.68 83/32 1 x34 0.18 1/4 4 1.93 7/32 11/4x1 0.25 1/4 5 3.53 7/32 11/4x3/4 0.24 9/32 6 5.63 7/32 kly 8 14.12 15/32 A V T- 701 Pedud ng Cbupl i ng Cx C-Cast ---• 7245-A NQM.SIZE - 3 x 1 1/4 1.35 23/92 F-�-Set FbMer Coup)i ng 3x1 1.64 27/32 C-Cast APPROX DIM.0 DIM.. NCM.SIZE • INCHES 1/2 0.05 15/8 23/32 314 0.09 15/8 27/32 1 0.13 15/8 1 Oxisult price sheet for Made to O-der it&Ts and for n i ni rrum order quantities. m NIBOOINC VVCRD HEADC LARf TS- 1516 MICOL13lk yST.• BXH&Rr,IN 46516-4740• U54• R-t 1.800.234.0277 TKHSERACFSR-t 1.888.446.4226• FAVC 1.8(10.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAx+1.574.205.3455 www.niboo.mmm NIBCCY www.nibco.com AHEAD OF • 0- COUPLI NGS continued CROSSES ELBOWS C p .� 606 A 46 B bow Cx C-Wrot --.- DIM. . . � . B I A A 1/8 0.01 1/4 1/4 736 1/4 0.02 9/32 9/32 Cross-Over Coup)i M A 3/8 0.03 3/16 3/16 Cx C-Cast 735 -1-1 1/2 0.04 9/32 9/32 /� /� /+ /+ /�, } 5/8 0.09 15/32 15/32 •� INCHES� • Coss Cx lax lax C-Cbst 3/4 0.10 11/32 11/32 • I 1/2 0.27 17/16 APPROK DIM.A 7/8 0.20 11/16 11/16 • - INCHES 1 0.16 3/8 3/8 3�4 0.60 129/32 318 0.09 3/8 11/4 0.25 17/32 17/32 1/2 0.15 7/16 11/2 0.35 19/22 19/32 3/4 0.30 9/16 2 0.65 21/32 25/32 1 0.54 23/32 21/2 1.07 29/32 L9/32 11/4 0.78 7/8 3 1.58 11/8 11/8 11/2 1.05 1 4 3.35 17/16 17/16 2 200 11/4 5 11.05 19/16 19/16 21/2 296 11/2 6 16.95 2 2 8 23.00 29/32 29/32 C e�"1 606-2 45° Fitting Bbow Rg x C-Wrot . INCHES INCHES 1/4 0.02 9/16 1/4 1/2 0.04 3/4 7/32 5(8 0.08 11/8 13/32 3/4 0.10 11/16 5/16 1 0.16 17/32 15/32 11/4 0.25 119/32 17/32 11/2 0.35 125/32 19/32 2 0.65 23/16 25/32 21/2 1.07 23/16 29/32 3 1.55 219/32 15/32 Qxlsult prioe sheet for Made to Q-der items and for n i ni rrum order quantities. NIBDJINGWCRDFEADCLART9T• 1516MICM83-WST• BJ44NUIN465164740• US4• R-t1.800.234.0227 m TEHSERACESPH 1.888.446.4226- FAX 1.800.234.0557• INTB+Al1CNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 www.riiboo.corn www.nibco.com AHEAD OF • ELBOWS continued irk C C C 706-2 707 607-LT 45° R tt i ng B baw Rg x C-Cast 90° B bow-0 ose Fbugh 90° 8 bow- Long Fbdi us . INCHES INCHES Cx C-Cast Cx C-Wrot --. 4 4.31 311/3 15/16 •M.SIZE NErWT./LBS. INCHES INCHES • . • ES INCHES 11/4x1 0.42 15/8 115/32 31160D. 0.01 13/3 13/3 11/4x3(4 0.34 9/16 13/16 1/8 0.01 13/3 13/3 11/4x1/2 0.28 15/32 2/32 5(160D. 0.02 9/16 9/16 11/2x1 0.54 11/16 1 1/4 0.02 17/32 17/32 9' + 11/2x3(4 0.42 19/32 31/32 1/4x1/8 0.01 19/32 1/2 11/2x1/2 0.40 5/8 29/32 3/8 0.04 23/32 23/32 2x11/4 0.86 7/8 11/4 1/2 0.08 7/8 7/8 2X1 0.78 3/4 11/4 1/2x3/8 0.06 13/16 13/16 2x3/4 0.69 5/8 11/4 1/2x1/4 0.03 25/32 21/32 607 21/2x2 216 13/16 19/32 58 0.10 13/32 13/32 90° B bow-Gose Rough 3x21/2 226 111/16 11/2 58x1/2 0.09 11/16 11/16 Cx C-Wrot 3x2 268 13/8 19/16 314 0.16 11/8 11/8 4x3 5.18 129/32 215/32 3/4x58 0.13 11/4 13/32 NCM.SIZE • • 3/4x1/2 0.10 11/8 11/16 1/8 0.01 13/32 13/32 7/8 0.28 119/32 119/32 1/4 0.02 9/32 9/32 1 0.28 17/16 17/16 3/8 0.03 7/z 7/z 1 x3/4 0.20 11/4 11/8 1/2 0.04 3/8 3/8 • 1 X58 0.15 113/32 13/32 1/2x3/8 0.04 9/16 21/32 11/4 0.42 17/8 17/8 3/4 0.10 17/32 17/32 0 1 1/4x 1 0.33 1'/32 11/2 3/4x58 0.12 29/32 7/8 11/2 0.66 21/4 21/4 314x1/2 0.10 17/32 3/4 2 1.23 215/16 215/16 1 0.21 23/32 23/32 6071 21/2 1.96 311/16 311/16 1 x3/4 0.16 23/32 5/8 W B bow- 3 2.93 41/32 41/32 11/4 0.31 11/32 11/3 Intermediate Fad us Cx C-Wrot 4 5.95 51/4 51/4 11/4x1 0.31 15/8 175/3 APPROX 11/2 0.46 17/32 17/3 • i • INCHES 11/2x11/4 0.35 15/32 13/32 1/2 0.06 19/3 19/3 2 0.84 11/2 11/2 58 0.09 7/8 7/8 2x11/2 0.58 17/16 11/4 3/4 0.14 13/16 3/16 21/2 1.41 127/32 127/32 1 0.24 11/16 11/16 3 207 23/32 23/32 31/2 294 23/8 23/8 4 4.23 225/32 225/32 5 7.74 27/8 27/8 6 10.95 37/16 37/16 8 29.50 423/32 423/32 Consult price sheet for Made to Qder items and for rri ni rrum order quantities. ® NIBMINr-WCRDFEADQ14RTEM- 1516MICD-EUWST.• aA-P f,IN46516-1740• USA- RA 1.806.234.0227 TEH SERAC1B A-t 1.8B8.446.4226- FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 04 ELBOWS continued n .-A '1 607-2 607-2-LT 90° Fitti ng B bow-Close Fbugh 90° Fitti ng B bow-Long Fbdi us 607-2-2-LT Rg x C-Wrot Rg x C-Wrot 90° Fitti ng B bow-Long Fbdi us ---. ---. Rg x Rg-Wrot INCHES NOM.SIZE NErWT./LBS. . ES NOM.SIZE 1/4 0.02 3/4 3/8 1/8 0.01 13/32 1/2 • I •••• ,INCHES 3/8 0.03 15/16 1/2 1/4 0.02 11/8 3/4 1/4 0.02 27/32 1/2 0.04 31/32 3/8 3/8 0.05 11/8 7/8 3/8 0.04 11/8 58 0.07 17/32 17/32 1/2 0.08 19/16 13/32 1/2 0.08 119/32 3/4 0.10 111/32 17/32 1/2X3/8 0.06 15/16 13/16 5/8 0.10 111/16 1 0.20 13/4 27/32 1/2x1/4 0.03 11/4 5/8 3(4 0.16 115/16 11/4 0.33 21/8 11/32 5/8 0.10 125/32 13/32 1 0.31 21/2 11/2 0.46 2 13/32 17/32 3/4 0.16 115/16 11/8 11/4 0.43 229/32 2 0.84 227/32 11/2 1 0.31 21/2 121/32 11/2 0.65 37/16 21/2 1.39 315/32 129/32 11/4 0.43 229/32 17/8 2 1.25 411/32 3 210 313/16 23/32 11/2 0.66 213/32 21/4 4 4.00 43/4 225/32 11/2x11/4 0.50 33/8 23/32 2 1.27 411/32 231/32 21/2 216 57/32 311/16 § 3 3.10 53/4 41/32 B C t707-2-4 607-2-1 R 90° Fitting Bbow 90° Fitting Bbow- Rg x M-Cast Intermediate Iadius 607-2-2 APPFUX DIM.B DIVE Rg x C-Wrot 90° Fitt i ng B bow-Q ose Fbugh I NErWT./LBS. INCHES INCHES 1/2 0.12 7/8 25/32 B RgxRg-Wrot . INCHES INCHES 1/2 0.06 15/32 19/32 • I --• •INCHES 58 0.09 1'/16 7/8 1/2 0.04 11/16 3/4 0.14 15/8 13/16_ 3/4 0.12 115/32 1 0.24 21/32 11/16 1 0.20 123/32 11/4 0.33 21/8 11/2 0.46 213/32 2 0.82 227/32 3 2.12 37/8 Consult price sheet for Made to Order iterrs and for n i ni rrum order quantities. NIB03ING WgaD FEADC LAR1H2S• 1516 MIDaEBLW ST.- 919-Aff,IN 46,5*4740• USA• R-t 1.800234.0227 TH7i S9RACES R-t 1.888.446.4226• FAX 1.800.234.055!- INTB:NAl1C NAL S9RACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.niboo.mm www.nibco.com AHEAD OF • ELBOWS continued 7Fc E �- ^ I' 707-3 707-3-5-A 707-46 90° B bow C x F-Cast 90° Hy-Set Elbow C x F-Cast 90° Uni on B bow C x M-Cast --. NCM.SIZE NErVVT./LBS. INCHES INCHES NCM.SIZE NErVVT./LBS. INCHES INCHES NCM.SIZE NETWT./LBS. INCHES INCHES 1/4 0.06 13/32 9/16 1/2 0.21 9/16 7/8 318 0.21 13/32 13/16 3/8 0.09 7/16 11/16 1/2 0.30 11/32 11/2 3/8x1/2 0.13 9/16 13/16 3(4 0.49 15/16 113/16 1/2 0.12 7/16 13/16 1 0.72 123/32 15/8 1/2x314 0.18 11/16 15/16 E 11/4 1.16 13/4 127/32 1/2X3/8 0.09 1/2 13/16 1/2x1/4 0.10 3/8 23/32 1 3/4 0.18 21/32 15/16 ° 3(4x 1 0.35 13/16 11/8 c 3/4x1/2 0.20 9/16 15/16 f 1 0.43 2532 11/4 707-3-6 1 x3/4 0.35 11/16 13/16 90° Union Bbow CX F-Cast a c 1 x 1/2 0.26 9/16 11/8 .---• 11/4 0.67 1 11/2 NCM.SIZE NEFWT./LBS. INCHES INCHES 11/4x3/4 0.47 9/16 111/16 1/2 0.31 11/8 7/8 707-5 11/2 0.89 11/8 15/8 3/4 0.49 17/16 1 90° prop 13 bow C C-Gast 2 1.46 13/8 115/16 1 0.79 17/8 11/4 ...0 NCM.SIZE INCHES INCHES 1/2 0.13 13/32 7/16 i 3/4 0.24 17/32 9/16 46 C c A e-.� L-M7 0. E e G 707-3-5 707-4 t �i 90° Drop B bow C x F-Cast 90° B bow C x M-Cast ° NCM. APPFCK DIMA DIM.C DIM.E APPROK DIM.C DIM.E A SIZE NErWULBS. INCHES INCHES • • ,E NEFWT./LBS. INCHES INCHES 318 0.12 11/32 7/16 11/16 3/8 0.08 5/16 7/8 707-5-A / �+ lam 3/8X1/2 0.18 11/32 9/16 13/16 1/2 0.12 7/16 15/32 9V 00 Hy la Set Bbow x -Cast 1/2 0.15 13/32 9/16 7/8 1/2x3(4 0.18 9/16 15/32 1/2X3/8 0.17 3/8 1/2 13/16 1/2X3/8 0.10 5/16 15/16 ••3( D• A ,• 7. ,•IM.D 3/4 0.28 17/32 21/32 15/16 3(4 0.21 9/16 111/32 3/4x1/2 0.24 17/32 9/16 15/16 3/4x1 0.33 21/32 113/32 1/2 0.13 31/32 7/16 3 0.21 15/16 9/16 9 9/1s/16 1 0.49 5/8 25/32 11/4 3(4x1/2 0.18 7/16 17/32 1 0.43 23/32 15/8 11/4 0.58 7/8 111/16 1112 0.81 1 131/32 2 1.38 11/4 29/32 Qxwlt price sheet for Made to Crder iterrs and for rri ni rrum order quantities. m NIB00INC WCR.DFEADQ14RTEM- 1516MICD-EUWST.- aA-14ff IN46516-1740- USA- RA 1.806234.0717 TITHSERAC1BRt1.888.446.4716• FAx1.800.234.0557• INTB:?VAl1CNALSERACER-t+1.574.295.3221• FAX+1.574295.3455 www.rliboo.com NIBCCY www.nibco.com AHEAD OF • 04 ELBOWS continued FITTI N REDUCERS - -. NCM.SIZE NETVVT./LBS. INCHES 4x31/2 2.09 25/8 t 4x3 2.00 31/32 f ff 4x21/2 1.56 31/32 4x2 1.76 313/32 A B 5x4 3.30 39/16 5x3 2.97 41/16 707-6 600-2 5x21/2 3.30 411/32 5x2 2.88 411/16 99 Union 8 bow Cx C-Cast Fitting Fbducer Rg x C-Wrot 6x5 5.56 43/16 APPROY, • ■ '• ■ 6x4 5.09 49/16 • i • • • i INCHES 6x3 4.67 51/16 3(8 0.17 31/32 5/16 1/4x1/8 0.01 15/32 6x21/2 4.47 511/32 1/2 0.24 1 7/16 3(8x1/4 0.01 19/32 6x2 4.51 519/32 3(4 0.39 117/32 9/16 3/8x1/8 0.01 25/32 8x6 1233 515/32 1 0.64 121/32 23/32 1/2x3(8 0.03 11/16 8x5 10.35 515/16 11/4 1.07 119/32 23/32 1/2x1/4 0.02 2/32 8x4 11.10 67/16 5/8x1/2 0.04 7/8 8x3 10.63 615/16 5(8x3(8 0.04 31/32 8x21/2 11.41 73/16 5(8x1/4 0.03 11/32 8x2 10.86 77/16 3(4x5(8 0.06 31/32 3(4x1/2 0.06 11/6 FLANGES - t 3(4x3(8 0.05 11/6 CLASS 125 3(4x1/4 0.05 13/32 1 x3/4 0.10 17/32 1 x5/8 0.09 13/8 708 1 x 1/2 0.09 11/4 90° Ranged Sink Bbow 1 x3(8 0.08 19/32 Cx F-Cast 1 1/4x1 0.15 15/16 11/4x3/4 0.16 11/2 NOR SIZE PP-• ■• a ■• ■ . INCHES 11/4x1/2 0.13 13/8 1/2 0.20 7/8 9/16 13/4 11/2x11/4 0.23 113/32 w 11/2x1 0.21 15/8 � ' 11/2x3/4 0.20 17/8 ��I 11/2x1/2 0.16 119/32 2x1 1/2 0.40 131/32 F 2x11/4 0.34 23/32 741 I� 2 x 1 0.35 127/32 2x3/4 0.35 127/32 Companion Range C-Cast IND 2X1/2 0.34 131/32 • ...• ■ ■ ■ ■ 21/2x2 0.65 131/32 • • look, • 21/2x11/2 0.65 23/8 1/2 0.55. 1/8 31/2 3/16 23/8 L=P 21/2x11/4 0.60 27/32 3(4 0.71 1/8 37/8 3/16 23/4 21/2x1 0.78 29/32 1 1.26 1/8 41/4 1/4 31/8 764 3x21/2 1.03 2/a 1 11/4 1.42 1/8 45/8 1/4 31/2 � 99 Double 8bow 3x2 0.99 29/16 11/2 1.82 1/8 5 5/16 37/8 3x11/2 0.81 219/32 2 276 1/8 6 3/8 43/4 Cx Cx C-Cast 3x1 1/4 1.29 31/4 21/2 4.29 1/8 7 3/8 5112 • . "`•. DIM.INCHES Dim ■ 31/2x3 1.48 211/32 3 5.26 1/8 71/2 7/16 6 1 x 314 x 3✓4 0.33 3/4 21/32 071irXES.. 4 7.60 1/s 9 7/16 71/2 5 9.04 /s 10 /16 81/2 6 1268 1/8 11 1/2 91/2 Consult price sheet for Made to Order items and NOTE Lim B=TbeaoptoFarWFace for rri ni mam order quantities. NIBO)ING WCRD FEADCLART9T• 1516 MIDDL83JW ST• al+PRr IN 465164740• L1SA• R-t 1.800.234.0227 TB I SERACES PH 1.888.446.4226- FAX 1.800.234.0557• IN1T33VAl1CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboo.00m www.nibco.com AHEAD OF • FLANGES - PLUGS STRAPS CLASS 150 q% -e H 623 616 Copper Hanger Strap APPROX 1 � n � Rtted Rug F# Wrot SIZE NErWT./LBS. g-APPROX DIM.A 3/4"Widex25R.RbI 1.93 F • INCHES 318 0.016 1/16 771 1/2 0.02 3/82 Companion Range C-Cast 314 0.24 1/8 NOR •-. • INCHES SIZE NEFVVT./LBS. • INCHES • ES RETURN BENDS 3/4 1.15 1/8 37/8 11/32 23/4 624 1 1.59 1/8 41/4 3/8 31/8 Tube Strap 11/4 1.91 1/8 45/8 13/32 31/2 E 11/2 2.59 1/8 5 7/16 37/8 NCM. , PP-• 2 4.10 1/8 6 1/2 43/4 1/8 0.01 21/2 6.22 1/8 7 9/16 51/2 1/4 0.01 3 8.03 1/8 71/2 5/8 6 318 0.01 4 11.85 1/8 9 11/16 71/2 1/2 0.01 5 15.69 1/8 10 3/4 81/2 518 0.02 6 20.32 1/8 11 13/16 91/2 638 314 0.02 NOTE dim B=TLb--aoptoHaVeRm Fbturn Bend Cx C-Wrot 1 0.02 ...• DIM.E DIM J 11/4 0.03 NOM.SIZE NErWTJLBS. INCHES • 11/2 0.03 1/8 0.02 21/32 1 2 0.04 1/4 0.04 21/32 11/2 �S 3/8 0.08 11/32 11/2 TEES 1/2 0.13 11/2 2 w 0.26 1'9/32 2 23 l 1 1 0.44 23/�z 3 11/4 0.70 23/4 4 c E 11/2 1.04 35/32 41/2 - 2 1.92 329/32 51/2 lal d E 775 705 Threaded Companion Range -T Baseboard Tee Cx Fx C-Cast F-Cast INCHES SIZE NErWT./LBS. • a INCHES NOM. i ■ 2 4.31 1 6 43/4 I 1/2x 1/8x3/4 0.15 7/16 9/16 11/16 21/2 6.30 11/8 7 51/2 a �1 1/2 x 1/8 x 1/2 0.11 7/16 7/16 9/16 3 7.13 13/16 71/2 6 739 314 x 1/8 x 1 0.29 5/8 3/4 13/16 4 10.20 15/16 9 71/2 Fbt urn Bend-Closed 314X1/8x314 0.19 9/16 9/16 11/16 Cx C-Cast 1 x1/8x1 0.32 23/82 23/32 3/4 APPRCK DIM.E DIMA 11/4x1/8x11/4 0.51 7/8 7/8 15/16 • INCHES INCHES 3/4 0.29 15/32 15/16 Ginsult price sheet for Made to Qder items and for ninirrumorder quantities. mNIB0JINCVVCRDFI58kDQ14R - 1516MICOLFBI-R'ST.- aW-IARr,IN46516-4740- U54- R-t1.800.234.0277 • TKH S6RACFS R-t 1.888.446.4226• FAX-1.800.234.0557• I993JAnG4AL SBRACE R-t+1.574.295.3221• FAX-+1.574.295.3455 www.niboaoom NIBCCY www.nibco.com AHEAD OF • 04 TEES continued i I D 5 C F 705-D 611 NOTE Tee suns are read R n x Ran x Oitlet. Vent 8 bow Cx C-Cast Tee Cx Cx C-Wrot APPROK DIMENSICNIS : ES INCHES • • 5/8 0.12 7/16 7/16 7/16 1/2 0.10 7/16 7/16 2/32 3/16on 0.01 7/32 7/32 7/32 5(8x5/8x3/4 0.15 23/32 23/32 1/2 3/4 0.20 9/16 9/16 29/32 1/8 0.02 1/4 1/4 7/32 5/8x5/8x1/2 0.11 7/16 7/16 13/32 1 0.31 23/32 23/32 11/32 1/8x1/8x1/4 0,02 13/32 13/32 1/4 5/8x5/8x3/8 0.09 7/16 7/16 5/8 1/8x1/8x3/16on 0.01 1/4 1/4 5/16 5/8X5i8X1/4 0.09 7/16 7/16 3/4 1/8x3/16naX1/8 0.01 1/4 11/32 7/32 5(8x1/2x5/8 0.10 7/16 5/8 7/16 5/16on 0.02 3/8 3/8 5/16 5/8x1/2x1/2 0.09 7/16 19/32 13/32 5/16onx5/16onx1/4 0.02 3/8 3/8 1/4 7 3 7 5/8x3/8x5/8 0.10 /16 /a /16 c 5/16onx5/16onx1/8 0.02 3/8 3/8 13/32 5/8X3/8X3/8 0.09 7/16 3/4 5/8 5/16onx1/8x5/16on 0.02 3/8 13/32 5/16 3/4 0.15 1/2 1/2 1/2 �-I E 5/16onx1/8x1/8 0.02 3/8 13/32 13/32 3(4x3/4x1 0.22 23/32 23/32 1/2 1/4 0.02 5/16 5/16 1/4 3/4x3/4x5/8 0.16 17/32 17/32 11/16 n 1/4x1/4x1/2 0.06 19/32 19/32 3/8 3/4x3/4x1/2 0.12 7/16 7/16 17/32 710-3 1/4x1/4x3/8 0.04 17/32 17/32 11/32 8/4x3/4x3/8 0.12 7/16 7/16 21/32 Tee Fx Fx C-Cast 1/4x1/4x5116on 0.02 5/16 5/16 5/16 3/4x3/4x1/4 0.12 13/32 13/32 23/32 1/4x1/4x1/8 0.02 5/16 5/16 13/32 3/4x3/4x1/8 0.12 7/16 7/16 13/16 APPROX ' • 1/4x1/4x3/16on 0.02 5/16 5/16 7/16 3/4x5/8x3/4 0.15 17/32 11/16 1/2 • 1/4x5/160nx1/4 0.02 5/16 3/8 1/4 3/4x5/8x5/8 0.15 17/32 23/32 11/16 1/2 0.20 9/16 7/8 7/8 1/4x1/8x1/4 0.02 5/16 13/32 1/4 3/4x1/2x3/4 0.15 17/32 25/32 1/2 3/4 0.37 11/16 1 1 1/4x1/8x1/8 0.02 5/16 13/32 318 3/4x1/2x1/2 0.12 13/32 19/32 1/2 3/4x3/4x1/2 0.31 11/16 31/32 31/32 318 0.04 11/32 11/32 11/32 3/4X1/2X3/8 0.12 7/16 21/32 21/32 3/4x1/2x3/4 0.29 11/16 1 15/16 3(8x3/8x1/2 0.07 17/32 17/32 3/8 3/4x3/8x3/4 0.15 17/32 17/32 1/2 3/4x1/2x1/2 0.27 11/16 31/32 7/8 3/8x3/8x1/4 0.04 11/32 11/32 15/32 3/4x3/8x1/2 0.12 7/16 23/32 17/32 3✓8x3/8x5/16on 0.04 11/32 11/32 11/32 3/4x3/8x3/8 0.12 7/16 23/32 21/32 3/8x3/8x1/8 0.04 11/32 11/32 11/32 7/8 0.31 23/32 23/32 23/32 3/8x1/4x3/8 0.04 11/32 17/32 11/32 1 0.30 11/16 11/16 21/32 3/8x 1/4x 1/4 0.04 11/32 17/32 15/32 1 x 1 x 11/2 0.60 111/32 111/32 31/32 3✓8X1/4x1/8 0.04 11/32 17/32 9/16 2s 1 x 1 x 1 1/4 0.42 1 1 /32 3/8x1/8x3/8 0.04 11/32 19/32 11/32 1X1X3/4 0.27 9/16 9/16 21/32 �E g 3/8X1/8X1/8 0.04 11/32 19/32 19/32 1 x 1 x5/8 0.26 9/16 9/16 7/8 1/2 0.06 11/32 11/32 11/32 1 x 1 x 1/2 0.23 15/32 15/32 23/32 1/2x1/2x1 0.29 1 1 21/32 1 x 1 x3/8 0.23 15/32 15/32 29/3 710-3-4 1/2x1/2x3/4 0.12 17/32 17/32 11/32 1 x 1 x1/4 0.23 15/32 15/32 1 Tee M x Fx C-03st 1/2x1/2x5/8 0.11 5/8 5/8 7/16 1 x3/4x1 0.29 11/16 7/8 21/32 APPROX DIMENSICNIS 1/2x1/2x3/8 0.07 5/16 5/16 13/32 1x3/4x3/4 0.26 9/16 23/32 3/4 • NEFWT. INCHES 1/2X1/2x1/4 0.06 5/16 5/16 9/16 1x3/4x1/2 0,� 15/3 21/32 23/3. 3/4 0.34 11/16111/32 1 1/2x3/8x1/2 0.07 7/16 17/32 3/8 Qrinr ... 3/4x3/4x1/2 0.33 11/16 17/32 31/32 1/2X3/8X3/8 0.06 5/16 17/32 13/32 1/2x3/8x1/4 0.06 5/16 17/32 17/32 1/2x1/4x3/8 0.06 5/16 5/8 9/16 arba2s.., Consult price sheet for Made to Oder iterrs and for ni ni rrum order quantities. NIBDJ ING WCR D FEADC L ARIUS• 1516 MIOM83 W Sr.• al+PRr IN 465164740• US4• R-t 1.800.234.0227 m T67-I SERACE5 PH 1.888.446.4226- FAX 1.800.234.0557• INTB+A-11CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.rliboo.com www.nibco.com AHEAD OF • TEES continued I-T NOTE Tee si es are read Rn x Rn x Qrtlet. 611 APPROX DIMENSICNS APPROX. DIMENSICINS NETWT INCHES Tee Cx Cx C-Wrot continued INCHES • . INCHES IF G 2 1.30 19/32 19/32 11/32 3 3.15 17/8 17/8 21/32 1x1/2x1 0.29 11/16 1 21/32 2x2x21/2 2.34 2 2 121/32 3x3x21/2 3.55 129/32129/32 23/8 1x1/2x3/4 0.27 9/16 13/16 3/4 2x2x11/2 1.17 11/4 11/4 123/32 3x3x2 3.19 115/32115/32 131/32 1x1/2x1/2 0.22 15/32 25/32 23/32 2x2x11/4 1.12 9/32 9/32 17/8 3x3x11/2 3.08 115/32 115/32 29/32 11/4 0.43 13/16 3/16 13/16 2x2x1 0.90 27/32 27/32 11/4 3x3x11/4 3.10 115/32115/32 27/16 11/4x11/4x2 1.13 130/3213D/3213/32 2x2x3/4 0.88 19/32 19/32 11/4 3x3x1 212 Z7/32 27/32 131/32 11/4x11/4x11/2 0.60 13/16 13/16 29/32 2x2x1/2 1.17 11/4 11/4 21/4 3x3x3/4 239 27/32 Z1/32 23/16 11/4x11/4x1 0.45 25/32 25/32 2x/32 2x1 1/2x2 1.16 19/32 17/8 111/32 3x3x1/2 1.82 27/32 Z7/32 23/8 11/4x11/4x3/4 0.37 21/32 21/32 3/4 2x11/2x11/2 1.15 11/4 13/4 123/32 3x21/2x3 3.08 17/8 23/8 131/32 11/4x11/4x1/2 0.30 1/2 1/2 25/32 2x11/2x11/4 1.15 7/32 13/4 111/32 3x21/2x21/2 3.12 129/32211/32 28/32 11/4x11/4 x3/8 0.34 23/32 23/32 29/32 2x1 1/2x3/4 0.83 21/32 15/16 17/32 3x21/2x2 228 115/321Z7/32131/32 11/4x1 x11/4 0.43 13/16 11/32 13/16 2x1 1/2x1/2 1.12 11/4 125/32 21/4 3x2x3 3.62 129/32 217/32115/16 11/4x1 x1 0.47 25/32 7/8 29/32 2x1 1/4x2 1.58 19/32 115/32 19/32 3x2x21/2 3.56 129/32 29/16 26/16 11/4x1x3/4 0.35 21/32 25/32 7/8 2x11/4x11/2 1.16 11/4 131/32123/32 3x2x2 3.22 115/32 131/32 131/32 11/4x1x1/2 0.30 1/2 5/8 29/32 2x11/4x11/4 1.19 15/16 111/32111/32 3x1 1/2x3 3.13 129/32225/32 23/32 11/4x3/4x11/4 0.42 13/16 11/8 13/16 2x1 1/4x1 0.90 27/32 19/32111/32 3x1 1/4x3 3.63 129/32 225/32115/16 11/4x3/4x1 0.45 25/32 11/32 29/32 2x11/4x3/4 0.85 21/32 1 18127 3x1x3 3.20 131/32219/32 23/16 11/4x3/4x314 0.37 21/32 15/16 7/8 2x1x2 1.11 11/8 125/32 11/4 3x3/4x3 3.55 131/32229/32 23/16 1 1/4x3/4x 1/2 0.30 1/2 3/4 29/32 2x 1 x 1 0.89 27/32 19/32 111/32 31/2 5.20 217/32 217/32 217/32 11/4x1/2x11/4 0.41 13/16 17/32 13/16 2x3✓4x2 1.15 19/32 23/16 11/4 4 8.12 213/32 213/32 217/32 11/2 0.61 31/32 31/32 29/32 2x1/2x2 1.15 19/32 23/8 11/4 4x4x3 6.70 21/32 21/32 2 21/32 11/2x11/2x2 1.11 125/32125/32 13/32 21/2 2.40 15/8 15/8 15/8 4x4x21/2 6.65 21/32 21/32 35/32 11/2x11/2x11/4 0.62 2/32 29/32 11/16 21/2x21/2x2 1.97 15/16 15/16 121/32 4x4x2 5.82 115/32115/32 27/16 11/2x11/2x1 0.55 11/16 11/16 7/8 21/2x21/2x11/2 1.53 13/32 13/32121/32 4x4x11/2 3.94 111/32 111/32217/32 11/2x11/2x3/4 0.45 11/16 11/16 11/32 21/2x21/2x11/4 1.72 13/32 13/32127/32 4x4x11/4 4.04 111/32111/32229/32 11/2x11/2x1/2 0.40 1/2 1/2 11/32 21/2x21/2x1 1.34 25/32 25/32 111/16 4x4x1 3.72 1 1 29/16 11/2x11/4x11/2 0.62 11/32 13/16 29/32 21/2x21/2x3/4 1.34 25/32 25/32 113/16 4x4x3/4 3.70 1 1 211/16 11/2x11/4x11/4 0.62 31/32 13/32 31/32 21/2x21/2x1/2 1.34 25/32 25/32 21/8 4x3x4 7.05 225/32 37/32 2 17/32 11/2x11/4x1 0.51 1/32 1 11/32 21/2x2x21/2 1.99 121/32 23/32 121/32 4x3x3 5.03 21/32 215/32215/32 11/2x11/4x3/4 0.49 11/16 13/16 11/32 21/2x2x2 1.95 111/32 15/8 123/32 4x3x21/2 5.04 21/32 215/32229/32 11/2x11/4x1/2 0.41 1/2 25/32 11/32 21/2x2x11/2 1.57 13/32 213/32 121/32 4x3x2 5.87 115/32131/32 27/16 11/2x1 x11/2 0.59 11/32 111/32 2x/32 21/2x2x11/4 1.57 13/32 119/32127/32 4x21/2x4 7.19 225/32 315/32227/32 11/2x1 x11/4 0.63 29/32 11/8 11/16 21/2x2x1 1.40 25/32 19/32 13/4 4x2x4 7.08 225/32319/32227/32 11/2x1 x1 0.54 25/32 11/16 11/32 21/2x2x3/4 1.35 25/32 19/32 127132 Cbdimedon rod page 11/2x1 x3/4 0.44 11/16 31/32 15/16 21/2x11/2x11/2 1.76 13/32 113/32 13/8 11/2x1x1/2 0.39 112 25/32 11/32 21/2x1 1/4x21/2 2.40 121/32 27/16 121/32 11/2x3/4x11/2 0.62 11/32 17/16 11/16 21/2x1 x21/2 2.04 121/32223/32 121/32 11/2x3/4x11/4 0.58 29/32 111/3211/16 21/2x3/4x21/2 2.00 121/32 211/16 121/32 11/2x3/4x1 0.54 '/32 11/4 11132 21/2x1/2x21/2 2.46 11/2 27/32 11/2 11/2x314x3/4 0.47 11/16 13/32 2x/32 artmes•• 11/2x3/4x1/2 0.39 1/2 29/32 31/32 Consultplioe sheet for Made to Order itermand 11/2x1/2x11/2 0.62 11/32 113/32 31/32 for ni ni rrum order quantities. Cbdirx es... mNIBDJING WC DFFADCUART9'S• 1516MIDaBUWST.• RN4- Rr,IN46516-4740• USA- R t 1.800.234.0227 ' 7 CH STR MCFS R-t 1.888.446.4226• FAx 1.800.234.0557• I WB:NA71CNAL SERACE R-t+1.574.295.3221• FAX-+1.574.295.3455 www.niboo.mmm NIBCCY www.nibco.com AHEAD OF • 04 TEES continued 611-F-E Heat Exchanger Tee CxCxC-Wrot Tube slips entirely through fitti M on smdI end of nn.Slurs sa m as listed under 611 where tee C p has one or more reductions on one end of nn. F 611 611-2 Tee Cx Cx C-Wrot continued Fitti ng Tee Cx Rg x C-Wrot APPROX • • - : � INCHES . . 5 8.29 227/32 227/32 313/32 _ ° 1/2 0.07 11/32 3/8 7/16 5 x 5x4 7.09 27/32 21/32 31/16 314 0.15 115/32 1/2 17/32 5 x 5 x 3 5.91 125/32 125/32 33/16 5x5x21/2 5.90 15/16 15/16 33/16 711 5x5x2 5.29 11/16 11/16 33/16 Tee Cx Cx C-Cast 5x5x11/2 4.87 11/32 11/32 33/16 APPROX DIMENSICNS 5x5x11/4 4.50 11/16 11/16 33/16 1 NErWT. • - NCm.SZE A 5x5x1 4.20 9/16 9/16 33/16 5x4x5 8.53 227/32429/32313/32 11/4x1/2x1 0.48 3/4 3/4 7/8 5x4x4 8.17 21/4 417/32 33/a 11/4x1/2x1/2 0.50 9/16 5/8 1 c c 5x2x5 9.47 23/4 51116 31/2 11/2x1/2x11/4 0.70 7/8 31/32 1 6 13.50 39/32 39/32 41/32 2x2x3 3.11 121/32121/32 15/16 711-5 6x6x5 11.67 211/32:221/32 41/32 2x1 x1 1/2 1.23 1 11/4 11/4 Drop Tee Cx Cx C-Cast 6x6x4 10.17 29/32 21/32 311/16 2x3(4x3(4 0.84 21/32 7/8 11/4 APPRaX DIMENSICNS 6x6x3 8.92 125/32 125/32 311/16 21/2x21/2x3 298 13/4 13/4 117/32 NErVVr. INCHIEB 21/2x11/2x2 202 11/4 115/32 11/2 • ' 6x6x21/2 8.11 117/32117/ 33/a 6x6x2 7.78 19/32 19/32 311/16 21/2xl1/2x11/2 1.76 13/32 113/32 13/8 1/2 0.16 3/8 7/16 6x6x11/2 6.86 1 1 311/16 21/2x1/2x21/2 246 11/2 27/32 11/2 6x6x11/4 6.66 29/32 29/32 311/16 3x3x4 6.96 211/ 211/ 121/32 6x6x1 7.19 9/16 9/16 311/16 3x21/2x11/2 253 1 13/32 13/4 6x6x3(4 7.18 9/16 9/16 49/16 3x2x11/2 262 1 11/a 13/4 6x6x1/2 7.17 9/16 9/16 411/16 4x4x6 16.47 37/32 37/32 21/32 6x4x6 16.60 33/16 51/8 41/8 4x2x2 4.64 11/4 13/4 21/a 6x4x11/2 9.62 15/16 215/16 33/4 8 36.81 41/16 41/16 51/32 8x8x6 27.86 31/16 31/16 51/8 8 x 8 x 5 24.90 225/32 22132 415/16 e 8x8x4 22.26 21/16 21/16 43/4 8x8x3 20.01 19/16 19/16 43/4 8x8x21/2 19.02 15/16 15/16 43/4 8x8x2 18.01 11/16 11/16 43/4 NOTE Tee sins are read Rn x Ran x C)jtlet. 711-A Supply and Fbt urn Tee Cx Cx C-Cast APPROX DIMENSICNS NEFWT INCHES • 1/2 0.17 13/16 1 Cbrls k price sheet for Made to C rder items and for ninimamorder quantities. NIBO)ING wCRD FEADCLART9T• 1516 MIDDL83JWSr.• al+PRr IN 465164740• L1S4• R-t 1.800.234.0227 T67-I SERACE5 PH 1.888.446.4226• FAX 1.800.234.0557• INTB+A-11CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.rliboo.com www.nibco.com AHEAD OF • TEES continued TRAPS 1 F +�a F F .Y 6 712 713 Tee Cx Cx F-Cast Tee CxCxM -Cast •-- . INCHES 3/8 0.11 11/16 7/16 7/16 1/2 0.14 13/16 7/16 7/16 1/2 0.15 13/32 7/16 3/4 0.33 1 21/32 21/32 3/4 0.29 19/32 9/16 698 1 0.54 11/4 7/8 7/8 11/2 1.08 15/e 11/8 11/8 - Sidi on Line RTrap 2 1.74 17/8 13/8 13/8 P11 CX C-Wrot 1/2x1/2x1/4 0.16 13/16 1/2 1/2 IL An-gorapplicationofthisfittingison the suction 1/2x1/2x3/8 0.15 13/16 1/z 1/z line ofarefrege-ation con-pressor The line is 1/2x1/2x3/4 0.23 15/16 11/16 11/16 looped,by use of the SUdionLine RTrap,tothe I floor prior to being run verticallyup✓vardsto 3/4x3/4x3/8 0.23 7/8 1/2 1/2 e ' prevent the drainageofal back to the 3/4x3/4x1/2 0.24 57/64 17/32 17/32 cmVessorduring shut down penods.Additional 11/4x11/4x1/2 0.49 11/4 9/16 9/16 714 RTraps are used for each 20'orriser0pe.this 1 1/4x1 1/4x3/4 0.55 15/16 11/16 11/16 Tee Cx Fx C-Cast prevents high velocity build-up as the al orliquid 11/4x11/4x1 0.66 17/16 7/8 7/8 -,-• • begiristoretumto the coYpressor dud ngthis 1 x 1 x 1/2 0.34 11/8 9/16 9/16 INCHES� shut down period. i - •-• . • 1 x 1 X3/4 0.42 13/16 11/16 11/16 INCHES 11/2x11/2x1/2 0.62 13/8 9/16 9/16 1/2 0.18 7/16 9/16 7/8 NCIVI. 11/2x11/2x3/4 0.70 17/16 11/16 11/16 1/2x3/4x1/2 0.27 7/16 9/16 13/16 1/2 0.36 53/8 3 3 6 11/2x11/2x1 0.79 11/2 13/16 13/16 3/4 0.31 9/16 11/16 1 518 0.45 53/8 27/8 3 6 2x2x1/2 0.97 15/8 17/32 17/32 3/4x1/2x3/4 0.26 9/16 9/16 15/16 314 0.58 53/8 23/4 3 6 2x2x3✓4 1.10 111/16 11/16 11/16 1 0.52 23/32 13/16 11/4 1 0.92 51/4 221/32 3 6 2x2x1 1.23 13/4 13/16 13/16 1x3/4x1 0.43 23/32 23/32 13/16 11/4 1.16 53/8 27/8 33/4 61/8 1/4 0.08 13/16 9/32 9/32 1 x 1/2 x 1 0.42 3/4 3/4 11/8 11/2 232 r/8 35/8 5 9 11/4 0.76 17/16 1 1 11/4 0.70 7/8 1 113/32 2 3.93 8 35/8 6 97/16 3/8x3/8x1/4 0.12 11/16 7/16 7/16 11/4x3/4x11/4 0.62 7/8 7/8 17/32 3✓4x1/2x3/4 0.28 1 21/32 11/16 11/4x1/2x11/4 0.56 7/8 7/8 13/16 3/4x3/4x1 0.40 11/8 7/8 7/8 11/2 1.00 1 11/8 19/16 11/2x3/4x11/2 0.88 1 1 113/16 2 1.72 11/4 13/8 17/8 2x3/4x2 1.57 11/4 11/4 2 1k e 2x1/2x2 1.58 11/4 11/4 2 C c 712-5 Drop Tee C x C x F-Cast --. NETWT. INCHES 1/2 0.25 3/8 9/16 7/8 Consult price sheet for Made to O-de"item and 3/4 0.38 1/2 21/32 1 for ninirrum order quantities. NIBMINC WCRDFEADCLARf9s• 1516MICOLB3UWSl• B104Wf,IN46516-1740• LISA- 841.806.234.0227 TEHSERAC1BA-t1.8B8.446.4226• FAX1.800.234.0557• INT9aVA-nCNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 0- UN I ON S VENTURI Fl J� ,FA 733-2 621 Fitting Union Rg x C-Cast Menturi Insert-Wrot 633-W DIM.B Converts any tee i nto a sped al purpose vent uri or Union Cx C-Wrot ,tee APPROK DIM.A 1 1/2 0.23 19/32 NC)M.SIZE NEWULBS. INCHES 314 0.35 15/8 NOVI. 1/8 0.10 5/8 1 0.55 127/32 1/2 0.01 - 1/4 0.15 11/16 314 0.02 318 0.22 7/16 1 0.03 1/2 0.31 13/32 _ _ 11/4 0.04 314 0.33 3/8 1 0.54 1/2 Y's A 733-3 Fitting Union Cx F-Cast F - APPRCK • NC)M.SIZE _NEFWT./LBS. INCHES A 1/4 0.14 15/32 � e 318 0.19 13/32 733 1/2 0.26 11/6 748 Union Cx C-Cast 314 0.37 15/16 90' Y Cx Cx C-Cast APPROK DIM.A 1 0.61 17/16 APPRICK NOM.SIZE • 11/4 0.98 119/32 NCIM.SIZE • INCHES 1/4 0.10 11/16 11/2 1.21 113/16 1/2 0.11 7/32 7/16 318 0.15 7/16 2 1.90 25/32 314 0.25 7/16 5/8 1/2 0.22 13/32 1 0.61 1/2 13/16 5(8 0.31 21/32 314 0.31 3/8 1 0.54 1/2 �- 11/4 0.76 1/2 2 1/2 2 1.04 1/32 7�4 A ° 1.77 /2 21/2 3.25 1 Union Cx M -Cast 3 4.75 15/32 APPROX DIM.A• 749 . - • 1/4 0.13 11/2 45 Y Cx Cx C-Cast 318 0.20 15/8 APPROX DIM,A • 1/2 0.28 111/16 NOUSIZE • 0. INCHES 1/2x314 0.35 21/16 1/2 0.15 13/32 7/8 314 0.43 129/32 314 0.30 117/32 17/32 1 0.68 21/8 1 0.55 113/16 115/32 11/4 0.95 25/32 11/4 0.81 21/4 17/8 11/2 1.35 213/32 11/2 1.14 26/8 21/8 2 2.17 221/32 2 2.17 35/16 23/4 21/2 4.13 313/32 Consult price sheet for Made to C rder itffm and for rrinirrumorder quantities. NIB03INC WCR.D FEADCLART9T• 1516 MIU183JW Sr.• al+PRr IN 465164740• US4• R-t 1.800.234.0227 T67-I SERACE5 PH 1.888.446.4226• FAX 1.800.234.0557• INTB+A-11CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.riiboo.com www.nibco.com AHEAD OF • Copper Cast oy R ared R tti ngs 100 Series-Heavy R ared 500 Seri es-R ared Adapters ......................................................23 Cauoirgs......................................................23 eboays ........................................................23 Nuts ..........................................................24 Tees ..........................................................24 rs09001z000 lhenetVaduingpartset Sath Cia-s Fe Is,W,, Stuarts Daft,VA Nam es,TX axlRyXsa Maamrraxfadue PlAdsuideraQ.dity M-ag-ert S,S—o3 f—rig tothea ertrersicnof1909001 IrterdiareI Sta>dmis NIBDDINC WCRDHE DaJ4Rfff5. 1516MIDDL®lR'ST.• BlOORr,IN46516-4740• USA- R-t 1.800234.0227 TBD I SERACE5 R4 1.888.446.4226• FAX 1.800.234.0557• INlB3JAl1CNAL SERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.00m NIBCCY www.nibco.com AHEAD OF • 04 ADAPTERS COUPLI NGS ELBOWS Fl 16 H�- 104 507 Heavy Rared Adapter Rared 90° 8 bow FL x FL—Cast RLxM—Cast DIM. -. . INCHES' IT NOM, • INCHES 101 1/2 0.54 15/8 314 0.60 21/2 Heavy R ared Coup)i M 314 0.77 131/32 1 1.24 31/4 1 1.60 2'/16 FL x FL—Cast 2 5.39 37/8 APPROX NCM.SIZE NETWT./LBS. INCHES IT (iR-F--, 3/4 0.98 313/16 1 1.70 55/16 ,�—B i 503 R ared Adapter FL x F—Cast E INCHES 507-3 1/2 0.36 17/8 R ared 90° 8 bow i-x F—Cast 314 0.48 21/32 1 1.03 23/4 — EO -•-• •• � �. � 11/2 1.99 37/32 1/2 0.49 15/8 11/2 2 3.22 39/16 � 3/4 0.69 115/16 15/8 501 e 1 1.43 29/16 21/4 R ared Goupl i M FL x FL—Cast NCM.SIZE NErWTJLBS. INCHES 1/2 0.45 23/8 s 3/4 0.60 21/2 ' s 1 1.24 31/4 - 504 11/4 2.18 31/2 R ared Adapter FL x M—Cast 21/2 2.03 �/32 I �I • 507-4 1/2 0.29 132/32 R aced 99 8 bow FL x M—Cast 314 0.58 211/16 _APPIRCK DIM. 1 0.88 33/16 N()M.SIZE • INCHES 11/2 1.89 33/4 1/2 0.34 111/16 113/32 2 2.95 415/16 3/4 0.55 131/32 119/32 1 1.34 23/32 2 11/2 280 35/16 21/2 ODrrAt price sheet for Made to Q-der iterrs and for n i ni rrum order quantities. NIBOJ ING WCR D FEADCLART9T• 1516 MIU183J 2i'ST• al+IARr IN 465164740• US4• R-t 1.800.234.0227 T67-ISERACESPH 1.888.446.4226• FAX 1.800.234.0557• INTB+Al1CNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboomm www.nibco.com AHEAD OF • NUTS +. T- L —,- B y 500 Tube Nut—Cast . . � . B 314 0.20 11/16 11/2 1 0.31 13/8 17/8 TEES K 6 B Q 511 R ared Tee FL x FL x FL—Cast --. : E3 1/2 0.67 15/8 15/8 15/8 314 1.09 2 2 2 1 2.08 25/8 25/8 25/8 Qx>sult prioe sheet for Made to Oder items and for rd ni m am order quantities. m NIBMINC WCRDFEADQ14Rf9s• 1516MICOLEmwST.• am-p f,IN46516-1740• LISA- RA 1.806234.0227 TEH SERAC1B A-t 1.8B8.446.4226- FAX 1.800.234.0557• IMffdVA-na PLSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 0- Copper • for PEKlinK Adapters ......................................................26 BassRug......................................................27 0 x0ings......................................................26 OirrpRngs ....................................................26 OirrpTod ......................................................27 6baws ........................................................26 RttingRes.................................................26 Tees ..........................................................26 Tube Oitter .....................................................27 I500001.2000 The naxdaduingpatsat SathoasFdls,W,, 9u3tsD-M,VA,Namgdod k—s,TX and Fbyrsa,ModoJ m tVactu-e rxoduds uda a 0 dity Mam-at SAemoaf—rg tothea�r AsicncfIS09001 Irterr-dio d 3adads NIBC D I NG WCR D FEADQ.14Rt9ZS• 1516 MI DDL®LR(ST.• 9J4-14Af IN 465161A40• USA• F}t 1.800.234.0717 TEIiS9RACSR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAT1QNALS9RACER-t+1.574.295.3221• FAX+1.574.295.3455 www.nboo.mm www.nibco.com AHEAD OF • ADAPTERS COUPLI N GS continued FITTING REDUCERS 1 � A- RD(60&FA FE*03 Coupl i ng Adapter FB(x F—Wrot FB(x&Ni vel R P—Wrot X00-2 Fitting Rluoer Ftg x F©(-Wrot APPROX . NCIM.SIZE . 1/2 0.123 21/16 1/2 0.035 11/2 NCM. INCHES 314 0.207 23/4 ELBOWS 1/2 0.035 15/8 3/4 0.059 113/16 A A Him �v �TYP TEES it c Adapter FD(x M-Wrot FBC607 i APPIRCK BS. DIM.A 8 bow FB(x FD(-Wrot i NOM.SIZE NErWT./L INCHES 112 0.110 21/4 '---•• •INCHES FD(611 A 314 0.196 21/16 1/2 0.045 11/4 Tee FD(x FD(x FD(-Wrot 3(4 0.084 17/16 APPROX DIMENSICNS T A INCHES MAE 71■ 1/2 0.070 21/4 11/8 11/8 — A 3/4 0.097 21/2 11/4 11/4 — FEX60&T, 1/2x1/2x3/4 0.112 23/4 1318 11/4 — ` 3(4x1/2x1/2 0.097 21/213/16 1 15/16 Adapter FB(x FB—Wrot OF... 3✓4x1/2x3t4 0.112 25/8 11/4 11/4 13/8 APPROX . 314x3t4x1/2 0.099 23/813/16 1 —• X07-FA 1/2 0.034 113/16 Faucet Elbow 3/4 0.054 2 CRIMP RINGS F�(x 9dvivel RP—Wrot COUPLI NGS NCM.SIZE NEFWT./LBS INCHES 1/2 0.049 17/16 0 A FEC6W F�(198 ai mp Rngs (Back) Goupi i ng FB(x Fes(-Wrot APPKX DIM.A NOM.SIZE • • FB907-3-5 1/2 0.013. 0.325 1/2 0.036 2 Drop Ear 8 bow 3/4 0.017 0.325 3/4 0.056 2 FEX x R P-Wrot APPROX NCIM.SIZE INCHES 1/2 0.187 21/4 Consult price sheet for Made to Oder items and for minim amorder quantities. © NIBOOINC VVCRD FffkD0114RL6S• 1516 MIDDL1SLR(SL• aW-IARr,IN 46516-4740• U54• R-t 1.800.234.0227 TKH S6RACFS R-t 1.888.446.4226• FAX 1.800.234.0557- 199:NAnG4AL S9RACE R-t+1.574.295.3221• FAX-+1.574.295.3455 www.niboaoomm NIBCO° www.nibco.com AHEAD OF THE FLOW WAsion 5/14/02 F L•r FE X841 4 Q •Tool APPROX NOM.SIZE NET WT./LBS. 11• 11. 11. 4.000 v E •' CUter APPROX NCM.SIZE NET WT:/LBS. 0.03 E • • Brass • APPROX NOM.SIZF NET WT/LBS. 0.0168 11 11 0.0801 Consult Ooesl-ieetfor Made to Crder iterns and for order• , www.riboo.com www.nibco.com AHEAD OF • Co uoirigs......................................................29 OirrpR ngs ....................................................29 Bbaays ........................................................29 Faucet Connectors...............................................29 Tees ..........................................................29 is0e001:2000 lherraxfaduirgbatsct S31h4err.Fdls,NY, Stoats Rat,\A Nawgbdes,IX aidFbArsek Moaaorraifadue poddsudaaQdity Mara-st8 —001farrirg totheametrWsicnd15 9001 Irterebad 3arrdr mNIBMINCWCRDFEAD0114RTEM- 1516MICD-BBLWST.• 9J4-P f,IN46516-1740• LISA- R-t1.800234.0227 • TEHSERAC1BA-t1.8B8.446.4226• FAX1.800.234.0557• INTB:?VAl1CNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.rtiboo.com NIBCCY www.nibco.com AHEAD OF • C,OUPLI NGS FAUCET OCN N ECTORS FB600 FB607-FA Coup)i ng—Barb x Barb 90° B bow Faucet Connector— Barb x Swivel RFS 1/2 0.04 ---•_ 3/4 0.06 1/2 without nut&washer 0.04 ELBOWS TEES FB607 90° B bow—Barb x Barb _ FB611 • -- • Tee—Barb x Barb x Barb 1/2 0.04 APPROX. 3/4 0.06 • 1/2 0.05 FAUCET 1/2 x 1/2x3/4 0.10 C✓�� 3/4 0.10 CON N E 3!4 x 3/4 x 1/2 0.08 3/4x 1/2x3/4 0.10 3/4x 1/2x 1/2 0.08 CRIMP RINGS FB600-FA Straight Faucet Connector— Barb x Swi vel R F5 -. NOM.SIZE NErWT/LBS. 1/2 without nut&washer 0.03 FE3198 Q-i n-p R —Copper APPROX NOM.SIZE NErVVT./LBS. 1/2 0.01 Oxr-Ailt price sheet for Made to Oder iterrs and 3/4 0.02 for rri ni rrum order quantities. NIB00ING WCR D FEADU-AR19ZS- 1516 MIDaEBLW ST.- RA-AW IN 46516-4740- USA- R t 1.800.234.0227 TffiiS9RAC6R-t 1.888.446.4226- FAY I.800.234.0557- INTB:NAl1CNALSERACER-t+1.574.295.3221- FAx+1.574.295.3455 www.niboo.mm www.nibco.com AHEAD OF • Wrot and Cast DWV Fi tti ngs Adapters....................................................31-33 Bushngs ......................................................33 C]eanouts......................................................33 Closet Ranges..................................................34 Cbuplings ..................................................... 34 ObDNs .....................................................35-36 Rugs .........................................................36 Fbtun Bends...................................................40 Tees ..........................................................37 TestCgm&Tees .............................................37-38 Traps.......................................................39 40 T-Ys ..........................................................38 Ys............................................................38 1505001:2000 The rrerx faduing parts at S thGe-sFalls,W,, Stuarts D-4t,VP,Naoogdodi—,TX and Reyrxsa,McAco rrendadue pc su-deraClefity Maw-al 9,s—oaf—g tothea re tme sicncfM9001 Irtenlaticrd 3axblce NIB0DING WCRDHE DCl14Rfff5. 1516MIDDL®lt;'ST.• Bt4-I4Rr,IN46516-4740• LJS4• R-t 1.800234.0227 TKH SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• IN1B3JA-ncNAL SERACF R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboaoom NIBCCY www.nibco.com AHEAD OF • 04 ADAPTERS - SLI P J OI NT ADAPTERS - SOI L PI PE - � I B 801-2-7 903-7 805 DkW Fitting Trap Adapter DW\/Trap Adapter DWV Soi I R pe Adapter Rg x SJ—Cast F x SJ—Wrot C x Spi got—Cast APPROX DIM.B APPROK DIM B Jdrlsoopper tube tocast iron soil pipes. NOM.SIZE NETVVT./LBS. INCHES NCM SIZE NETWT./LBS. IN(5�13S APPROX DIM.A 1114 x11/4OD. 0.25 119/32 11/4x11/401). 0.32 17/1s NOM. ' INCHES 11/2x11/2OD. 0.42 17/16 11/4x2 0.93 39/32 11/2x11/4OD. 0.43 119/32 2x4 2.52 37/3 3 1.56 23/4 _ 3x4 2.78 313/16 4 2.23 3 � R 901-2-7 D►VW Fitting Trap Adapter Ftg x SJ—Wrot 9047 DM Trap Adapter NOM.SIZE NErVVT./LBS. INCHES M x SJ —Wrot 905 11/2x11/2QD. 0.29 17/16 ..._. DIM.B DMSaI Rpe Adapter 11/2 x 11/4QD. 0.24 17/16 CX Spigot—Wrot 11/4x11/4OD. 0.41 13/4 Jd ns oopper tube to cast i ron sci 10 pes. 11/2x11/2QD 0.51 12'/32 APPROX • 11/2 x 11/4 OD. 0.49 121/22 ' ' INCHES 11/2x2 0.60 37/16 2 0.44 29/16 — A, 901-7 DW\/Trap Adapter Cx SJ —Wrot �I • 805-N 11/4 x 11/4 OD. 0.21 21/32 DM No Hub Soi I R pe Adapter 11/2 x 11/2 QD. 0.27 3/4 Cx No Hub—Cast 11/2x11/4 OD. 0.24 7/8 • • 11/2x2 0.42 17/32 2 0.40 13/16 3 0.75 13/16 Consult pri oe sheet for Made to Qder iterrs and 4 1.23 17/32 for n i ni rrum order quantities. NIBDJ INC WCR.D FEADCLART9T• 1516 MIU183JW ST• al+IARr IN 465164740• USA• R-t 1.800.234.0227 T67-ISERACESPH 1.888.446.4226• FAX 1.800.234.0557• INTB+Al1CNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboomm www.nibco.com AHEAD OF • ADAPTERS - ADAPTERS - THREADED continued SPECIAL LEAD 801-T 802-F 803-2 DVV\/Trap Adapter DWVThreaded Rece D4M/Fitt i rig Adapter Cx0D. Tube-Cast CxM-Cast RgxF-Cast APPROX, DIM.C Males sl i pjoi nt oonnedion when soldered to the APPROX. • • end of tube and sl i p j of nt nut and washer added. • . • - 11/4x11/4OD, 0.21 1/6 APPROX DIM.- 11/2 0.39 115/32 11/2 x 11/2 OD. 0.22 7/32 NCM.SIZE INCHES 2 0.56 119/32 11/2x11/4 OD. 0.20 9/32 11/4 0.05 3/6 3 1.44 27/32 11/2 0.05 3/6 ADAPTERS - 2 0.05 3/8 THREADED 903-2 C 803 DM Fitting Adapter 802 IB D^M/Ada ter Rg x F-Wrot - DVWAdapter Cx F-Cast ...-• •. . Cx M-Cast APPROX DIM.A 11/4 0.19 117/32 DIM.C APPROX DIM._ NCM.SIZE INCHES INCHES • 3 1.45 113/32 11/4 0.23 15/16 7/16 4 2.31 117/32 11/4x11/2 0.41 1 1/2 11/2 0.25 1 7/16 2 0.33 11/16 7/16 a�-3 0.92 11/2 3/4 41 (.)04 35 .* 13WAdapter CxM-Cast 19 903 -• • . INCHES D W Adapter 11/2 0.34 - 13/64 �,- Cx F-Wrot 1 1/2x2 0.55 15/16 $OZ C NOM. APPROX DINCHES 11/2x11/4 0.31 27/32 SIZE DM Rush Adapter 1 1/4 0.19 - 27/32 2 0.43 7/8 Cx M- St 1 1/2 0.25 29/32 2x 1 1/2 0.52 15/16 � 3 1.35 125/3z ---• DIM.B DIM.C 2 0.41 1 4 2.59 21/32 NOV. i E NEFWT./LBS. INCHES INCHES 11/4 0.16 15/16 7/16 11/2 0.20 15/16 9/16 2 0.23 11/16 5/8 Qxmlt price sheet for Made to Order items and for n i ni rrum order quantities. ® NIBOJINC wC}iD HE DC WRT6S• 1516 MIM93R'ST.• RN4- Rf,IN 46516-4740• USA• R-t 1.800.234.0227 TKH SERMCFS R-t 1.888.446.4226• FAx 1.800.234.0557• I WB:NAnGL AL SERACE R-t+1.574.295.3221• FAX-+1.574.295.3455 www.niboo.mmm NIBCCY www.nibco.com AHEAD OF • 04 ADAPTERS — BUSHI NGS CLEANOUTS THREADED continued lip Ji 9, Tff ii k ill I L 904 801-2 816 D4M/Adapter D►WExternal Bushing DV\/\/Fitt ingGeanout Cx M—Wrot Rg x C—Cast Rg x CI eanout w/R ug—Cast •M,S= NErWT./LBS. INCHES NCM. i E NEFWT./LBS. INCHES NCM. INCHES 11/4 0.30 13/82 3x2 0.61 111/32 11/4 0.49 25/32 11/4x11/2 0.37 13/16 3x11/2 0.60 15/16 11/2 0.60 21/4 4x3 1.12 121/32 2 0.87 23/8 4x2 1.16 13/4 3 2.37 39/82 40 4 3.99 35/8 1,—. ��11 -h 804-T DW\/Trap Adapter 0.D. Tube x M —Cast " 901-2 • ..-• •INCHES DW\/External Bushing 816-S 11/4 OD.x 11/2 0.44 19/82 Rg x C—Wrot DV\/\/Rush Rtti ng Cleanout . INCHES Rg x CI eanout w/R ug—Cast iwr 1 1/2x 11/4 0.13 1 NC)M.S17F NETWULBS. INCHES 2x11/2 0.19 1/32 11/4 x 3/4 0.20 15/32 2x11/4 0.19 13/8 11/2x1 0.29 11/16 2 x 1 1/2 0.42 17/32 B 3x21/2 0.96 113/16 804-2 ____________ 4x3 2.25 21/8 DNW Fitting Adapter Rg x M—Cast -----_ NCM.SIZE • C 11/2 0.50 115/16 2 0.71 21/32 901-2-F DAN Rtti ng Rush Bushi ng Rg x C—Wrot --. . INCHES 2x11/2 0.37 13/16 1/8 Consult price sheet for Made to O-der items and for n i ni rrum order quantities. NIBOJING WgaDFEADCLAR1H2S• 1516MIDaEBLWST.- BXFAW IN465164740• USA• R-t 1.8x0234.0227 TH7i S9RACES R-t 1.888.446.4226• FAx 1.800.234.055!- INTB:NA-1C NAL S9RACE R-t+1.574.295.3221• FAX+1.574295.3455 www.niboo.mm www.nibco.com AHEAD OF • CLOSET FLANGES COUPLI N GS t -L-� r�x at 801 DWV Coup)i ng Cx C-Cast APPROX. DIM.A NCM.SIZE NErWT./LBS. INCHES f 3X2 0.70 11/16 ` 3x11/2 0.68 15/16 4x3 0.98 9/32 851-C 4 x 2 1.34 11/4 DWA/Q oset Range 851 C—Cast DW Coset Range ..-• DIMENSIONS. C—Cast APPROX DIMENSIONS 4x3 1.31 11/16 '/z 6'/8 6 II INCHES SIZE 4 1.45 5/8 7 6 901 4x3 2.18 111/16 7 6 DV\A/COUpI I Clg Cx C-Wrot . INCHES 11/4 0.07 3/32 11/2 0.09 3/32 IC> 11/2x11/4 0.13 5/16 2 0.14 3/32 2x11/2 0.19 15/32 -------------------L 3 0.45 3/32 4 0.57 1/8 951 DW V Cl oset Range C—Wrot ` ..-• : 901-RP INCHES DM F"i r Coup)i ng(No Stop) 4x3 0.84 111/16 63/4 6 Cx C-Wrot APPROX NCIM.SIZE INCHES 11/2 0.09 113/32 2 0.14 117/32 3 0.42 12'/32 4 0.57 213/32 Consult price sheet for Made to Q-der items and for n i ni mum order quantities. © NIB00INCVVCRDFI58kD011ARfBS- 1516MIDDLB3UR'SL- R K1UIN46516-1740- USA- R-t1.800.234.0227 ' TKH SERACE5 R-t 1.888.446.4226- FAx 1.800.234.0557- IMffdVAl1CNAL SERACER-t+1.574.295.3221- FAX-+1.574.295.3455 wwwriboamm NIBCCY www.nibco.com AHEAD OF • ELBOWS r � L 806 906-2 907-LT DW\/45° B baw DWV45' Fitting B bow DWV 90' Long Padi us B bow Cx C—Cast Rg x C—Wrot Cx C—Wrot NOM.SIZE NEWE/1-13S. INCHES NOR SIZE NErV\rT./LBS. INCHES INCHES NCM.SIZE NErWT/LBS. . ES 4 247 117/32 11/4 0.13 13/16 1/2 11/2 0.41 25/16 11/2 0.21 11/4 9/16 2 0.62 23/4 2 0.39 15/8 13/16 3 0.84 17/8 13/8 I —cam 906 Dvw45D B bow Cx C—Wrot 807 807-2 ....• D�W90° Bbow CWV90° Fitting Bbow • RgxC—Cast 11/4 0.13 1/2 Cx C—Cast ...,• . • 11/2 0.21 9/16 APPIRCK DIM.0 DIM.. NCM. , • a INCHES 2 0.38 13/16 NCM.SIZE • S INCHES 4 3.84 413/16 32/32 3 0.78 016 11/2x11/4 0.43 11/4 13/16 2x11/2 0.71 111/16 17/16 3 2.30 27/8 27/8 F 4 3.92 325/32 32/32 GL i T p e 806-2 Aem 907-2 DAV45 Rtting Bbow T-4 DWV90' Rtting Bbow Rg x C—Cast 907 Rg x C—Wrot --• • DIM 90 B bow 4 2.81 219/32 117/32 Cx C—Wrot 11/4 0.19 17/8 13/16 ••.• DIM.0 DIM.• 11/2 0.33 23/16 17/16 NOR SIZE • ES INCHES 2 0.59 211/16 17/8 11/4 0.18 13/16 13/16 3 1.21 311/16 211/16 11/2 0.32 17/16 17/16 2 0.513 115/16 115/16 3 1.20 211/16 211/16 Consult 0 ce sheet for Made to C rder items and for rri ni rrum order quant iti es. NIBDJINGWCR.DFEADCLART9T• 1516MIDDL®lk'2i'Sr- al+PRrIN465164740- USA- R-t1.800.234.0227 T ISERACESR-t 1.888.446.4226- FAX 1.800.234.0557- INTB+A-11CNALSERACER-t+1.574.295.3221• FAX-+1.574295.3455 wwwAboomm www.nibco.com AHEAD OF • ELBOWS continued C t � 807-3 960 DEW 90° B bow DEW 60° B baw Cx F—Cast 837 Cx C—Wrot ' D-+VW 90° Ebu�b-,l}e B bow --• • NOM.SIZE 1 1/2 0.72- 113/32 21/8 l.ix Cx C—Cast 11/2 0.24 . 13/16 2 1.15 17/8 211/16 APPROX DIM.0 IDIM.G 2 0.44 11/8 NCIM.SIZE • a • a 3 0.95 17/8 11/2 0.77 113/32 113/32 2 1.31 17/8 17/8 I 2x11/2x11/2 0.97 15/8 11/2 4 T 807-4 861-LH DV\/\/90° B bow , DW\/90° B bow Cx M—Cast w/Low Heel Inlet . . � . � Cx Cx C—Cast ,3 ..-• DI• INCHES• 11/2 0.66 1 /sz 23/32 DVW221/2 Bbow Cx C—Cast 3x3x2 2.43 27/8 19/32 �@ - PLUGS 11/4 0.22 3/16 11/2 0.28 1/4 i r- 2 0.48 11/32 B 3 0.99 17/32 L _ 818 AS.A D►W R ug M—Cast 807-9 APPROX DIM._ DWV 90° B bow w/Side Inl et INCHES Cx Cx C—Cast 809 3!4 0.08 2/32 APPROX . : DAM/111/4 B bow 1 0.12 29/32 • 11/4 0.19 31/32 • ' CX C—Cast 11/2 0.21 13/32 3x3x2 2.55 27/8 15/8 27/8 APPROX DIM.0 1 2 0.34 15/16 NOM.SIZE INCHES 1112 0.22 5/32 2 0.38 3/16 mrmlt pri oe sheet for Made to Order items and for n i ni rrum order quantities. © NIB00INC WCRDFffkD011ARfBS- 1516MIDDLEKWST.- R K1Rf,IN46516-1740- LISA- 1914 1.800.234.0227 TKH SERACE5 R-t 1.888.446.4226• FAX 1.800.234.0557• IMffdVAl1CNAL SERACE R-t+1.574.295.3221• FAX-1.574.295.3455 wwwriboamm NIBCCY www.nibco.com AHEAD OF • 04 TEES C-1 t r a 811-14 811 DWV Tee D W lbe Cx Cx F-Cast 835-B Cx Cx C-Cast APPROX, DIMENSICNS DWV Doubl e LT Tee INCHES --. CxCxCxC-Cast NEFWT INCHES • I 11/2 0.88 23/16 "/16 113/32 •�PPRO ■ • 3 2.84 253/64 125/64 253/64 2 1.57 223/32 11/16 17/8 • S • ■ G 3x3x2 1.82 23/8 11/8 17/8 2x2xl1/2 1.17 27/16 7/8 17/16 2x11/2x11/2x1112 1.73 23/8 31/16 321/32 3/32 3x3x1 1/2 1.58 25/32 15/16 17/16 ■. 4 4.92 313/16 2 313/16 TEST CAPS 4x4x3 3.49 311/32 119/32 27/8 4x4x2 2-91 27/8 15/32 113132 ri s wv f T--1 -----L h - 811-15 DVW Tee 917-B r L Cx F x F-Cast Test Caps-Copper APPROX ■ . C-Wrot NEFWT • 911 NCIM.SIZE LBS. = E G - 11/4 0.73 125/32 11/2 15/32 • ■ CWVTee INCHES Cx Cx C-Wrot 1/2 0.01 3/16 APPROX ■ • 374 0.01 3/16 IJ INCHES 1 0.01 1/8 • 11/4 0.01 1/4 11/4 0.32 11/8 13/16 11/8 11/2 0.01 1/4 11/2 0.49 113/32 29/32 113/32 2 0.02 1/4 11/2x11/2x11/4 1.58 26/32 15/16 17/16 • 3 0.03 1/4 2 0.78 127/32 11/8 17/8 4 0.05 5116 2x2x11/2 0.73 15/8 15/16 13/8 2x2x11/4 0.51 11/2 13/16 11/8 835 2x1 1/2x2 0.80 127/32 125/32113/16 DEW Double Tee _ 2x11/2x11/2 0.73 15/8 11/4 13/8 CxCxCxC-cast APPROX ■ .INCHES• • 11/4 0.65 15/32 3/4 15/32 11/2 0.85 113/32 13/16 113/16 11/2x11/2x11/4x11/4 0.72 19/32 3/4 75/32 2 1.38 17/8 11/16 17/8 2x2x11/2x11/2 0.99 121/32 7/8 17/16 2x2x1 1/4x1 1/4 0.93 117/32 25/32 15/32 2x11/2x11/2x11/2 0.94 121/32 2/32 17/16 Corsult price sheet for Made to Oder items and 3x3x2x2 2.36 29/8 11/8 17/8 for ninirrum order quantities. 3x3x11/2x11/2 1.51 25/32 31/32 115/32 NIBDJ INC WCR D HI5 DCU4RT9T• 1516 MIU183 W ST• BJ4*Rr IN 465164740• US4• R-t 1.800.234.0227 T67-I SBRACES PH 1.888.446.4226- FAX 1.800.234.0557• INTB3JAl1CNAL SBRACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.riboo.com www.nibco.com AHEAD OF • TEST TEES Y's continued 1 � ; u f 814 S DVM/Test Tee Cx Cx aeanout w/Aug—Cast , ..-. NOM.SIZE INCHES INCHEB a 11/2 1.00 21/16 11/8 ff { 2 1.35 211/82 13/8 3 3.78 37/16 115/16 i T Y's 5 1 t� 810 o D4M/450 Y : U CxCxC—Cast L/ APPROX DIMENSIONS nmu can NE'-VVT. INCHES NOM.SIZE 812 ,.t— 11/4 0.60 2 2 3/8 - 834 D4M/Long Turn T Y 11/2 0.94 251 16 7/16 1/2 - D \/45 Doubll eyY Cx Cx C—Cast 2 1.26 21/8 27/8 17132 Cx Cx Cx C—Cast APPROK DIMENSIONS 2x2xl1/2 1.15 2"/16 29/16 3/16 - NETWT. I NCHES 2x2xl1/4 1.01 29/16 217/82 1/16 - R• . E • • . • a 2xl112x2 1.16 217/32 25/8 17/32 - NCIM. §11/4 0.93 227132 127122 26/4 1132 2xl1/2xl1/2 0.84 25/32 25/32 5116 - 2 1.90 27/8 27/8 17/32 - 11/2 0.87 35/16 2118 35/32 7116 3 3.19 41/64 41/64 45/64 - 2x2xl 1/2xl 1/2 1.26 211/16 29/16 3/16 - 2 1.84 41/4 23/4 41/16 1/2 3x3x2 202 317/32 35/16 1/8 - 3 4.20 413/32 413/32 21/32 - 2x2xl1/2 1.07 35/8 23/8 37/32 7/32 3x3xl1/2 1.69 31/4 215116 - 3116 3x3xl 1/2xl 1/2 2.09 31/4 215/16 - 5116 3 3.49 67/16 41/32 61/32 3/4 4 5.55 515132 515132 11/16 - 3x3x2 2.78 47/8 35/16 45/32 3/32 4x4x3 3.96 411/16 41/2 5/16 — 4x4x2 290 47/32 313/16 - 3/8 o 1 7—� K J 1 DAM/Double Long Turn TY CxCxCxC—Cast DIMENSIONS APPROK EB . , 11/2 1.25 35/16 21/8 35/32 7/32 2 0.87 35/16 21/8 35/32 7/16 2x2xl 1/2xl 1/2 1.96 35/8 23/8 37/32 7132 2x2xl 1/4xl 1/4 2.67 311/16 23/8 37/32 7/32 Corisultprioe sheet for Madetotrderitermand for rrinirrumorder q-ontities. NIBMINCVVCRDH[5ADQ14RTEM- 1516MICELB3LR(SL- RK4NRFIN46516-4740- U54- R-t1.80D234.0227 TEH SERACES R-t 1.888.446.4226- FAX 1.800.234.0557- INTB:NAnCNAL SERACE R-t+1.574.295.3221- W+1.574295.3455 www.riboo.00m NIBCCY www.nibco.com AHEAD OF • 04 TRAPS e K 111E 890 881 892 3 x 5 D4M/Drum Trap DWM/P-Trap DAM/RTrap w/Uni on Joi nt w/Bottom Inlet Cx SJ—Cast Cx SJ—Cast Cx Fx Cleanout w/Rug—Cast • •-. -. ES INCHES 13 17 11/2 1.86 11/8 35/32 25/8 31/16 • i 1 1/2 1.50 1 /3z 2/3z 2/z 3 /3z 11/2 1.97 39/32 1'/2 23/8 2 2.64 115/32 313/32 31/8 321/32 —A� I • 891 C4M/P-Trap w/Qeanout 892-3 3 x 6 DAM/Swivel Drum Trap C x \/ Cl eano/ w/eanout —Cast DAA/P-Trap w/Uni on J of nt C x C x Cl eanout w/A ug—Cast Fx SJ—Cast --. • - --• • • Y' -• A---• . • INCHES • i INCHES NC)IVI.SIZE 11/4 1.21 15/32 117/32 21/4 33/32 • 11/2 290 621/32 11/2 1 31/8 11/2 1.53 113/32 115/32 Z/2 317/32 2 2.89 113/32 313/32 31/8 329/32 2 226 17/8 113/32 3 43/32 3 5.74 27/8 115/16 4 521/32 1101!17W, , d A� j A � 880 892-A D4\/\/RTrap w/Q eanout 885 r DuVV P-Trap w/Uni on Joi nt Cx SJ x Q eanout w/A ug—Cast DW\/RTrap Fx SJ x 0eanout w/A ug—Cast APPROX DIMENSICINIS Cx C—Cast APPROX DqMENSICNS APP-O NErWT. INCHES NETWT. INCHE • S 11/2 1.80 113/32 27/32 21/2 317/32 • . INCHES 1 1/2 1115/16 7 1 17/3z .88 2/a2 2/z 3 2 2.66 17/8 27/16 3 43/16 11/4 1.09 15/32 117/32 21/4 33/32 11/2 1.45 113/32 115/32 21/2 317/32 2 211 17/6 113/32 3 43132 3 5.17 27/8 115/16 4 327132 (insult price sheet for Made to Qrder items and for n i ni rrum order quantities. NIBDJINGWCRDFEADCLART9T• 1516MIU183JWSr.• a1+IARrIN465164740• US4• R-t1.800.234.0227 TB I SERACE5 PH 1.888.446.4226• FAX 1.800.234.0557• INTB+A-11CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.rliboo.com www.nibco.com AHEAD OF • TRAPS cont. RETURN BENDS V4jP g E 4 c 87-5-S 878 879 DAM/Trap Upturn DVS/Pet urn Bend M x S—Cast CNV�/F�turn Bend w/Qeanout APPRaX • Cx Cx aeanout w/Rug—Cast Cx C—Cast --• °. INCHES 11/2 1.20 1a1/6a 19/6a 4 - 17 1 11/4 0.76 117/32 21/4 1 1/4 0.81 1 /3z 2/a — — 11/2 0.98 115/32 21/2 — 11/2 0.90 115/32 21/2 — 2 1.40 113/32 3 — 11/2x11/2aa 1.00 115/32 21/2 — 3 3.34 115/16 4 — 2 1.25 113/32 3 — 2x11/2ao. 1.23 117/32 3 119/32 2x11/2 1.37 117/32 3 119/32 3 2.77 115/16 4 — Caisult Vioe sheet for Made to Adel-iterrs and for n i nirrum order quantities. NIB0JINCWC}iDHI5DCUART6'S• 1516MIM93R'ST.• RW-PKIN46516-4740• U54• R-t1.800.234.0227 TKH SERACFS R-t 1.888.446.4226• FAX 1.800.234.0557• I WB:NAnG4AL SERACE R-t+1.574.295.3221• FAX-+1.574.295.3455 www.niboaoomm NIBCCY www.nibco.com AHEAD OF • 0- Engi neeri ng Data Engineering Data continued Bras ng AI I oy Sol der Joi nt Fi tti ngs Oxisurption ...................................................45 Dirrendons ....................................................48 RidionL.oss Allwvances..........................................56 Brazing Fittings Installation Techniques ...........................................85 Dirrons ....................................................49 Tderarces .....................................................48 Ridion Loss Allavances..........................................56 Installation Techniques ........................................8687 Specifications Td erances .....................................................49 Tderar>ces Rttings...............................................44,48-09 Copper Tube Atti ngs Tubing...................................................50-53 BrazinglnFonreticn ..............................................45 Mdves Fitting Terns and Abbreviations....................................42 Fiction Loss Allaaanoes ......................................56 RurrbingSgdemFailures.........................................43 Farted Inten-d WorWrig Ressures................................4647 Working Fressures Solder and Rux Fbquirerrents .....................................45 Joi nts...................................................46-47 Solder Joint Sp ecification.........................................44 Tuning ...............................................5453,57 Td erar>ces .....................................................63 Typesof Joints..................................................42 Copper Water Tube GonWative Data with Iron Rpe ...................................54 Installation Instructions amensional Data.............................................5453 Bparsicn and Contraction ........................................55 Internal Working Ressures........................................57 The F ne Art of Bras ng .......................................8657 Selection of Tube Sms...........................................56 Td erances ..................................................5453 The Fine Art of Soldering ........................................85 Types,Standards,Applications,Tenpers and LaVhs ..................84 Water Ram and RidionL9ss ...................................58-83 Polybutylene Installation ........................................89 Frequentl y Asked Questi ons.....................................go Pol yethyl ene(PEA I nstal I ati on ..................................88 Joi nts Abbreviations...................................................42 Raarig .....................................................8687 Soldering ......................................................85 Numerical Index Types .........................................................42 Solder and R ux Numerical Index ................................................92 Fbtings........................................................46 Fequirenents...................................................45 _ � 7k IS09001:2000 Then Lfaduingpantsat SouthG sFIls,W,, 9 uats Daft,VA Naagdod>es,TX aid Fby>R Modm rra Vack e podrds miler a Qelity Maya-et 9�stem-f—ng tothearret rakicnat 1939001 Irten-dicrel Sam NIBC D I NG WQaD FEADCLAWE FS• 1516 MI DDLE W ST.• BJ4-WAS IN 465161A40• USA• R t 1.800.234.0717 m TEIiSERACESR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAflCNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.nboo.mm www.nibco.com AHEAD OF • CJ T_ P ff- TLUbb Ftt I ngs ■ Flared Joint—Theprinciple of the flared joint was first developed connection,or to add copper tube to f I anged pipe installations or for copper tube plumbing in 1928 by NI BCD.The flared type joint i s other purposes,NI BOO provi des flanges.The flanges are produced in whd I a mechanical means of jci ni rig copper tubes.The tube nut is two standard types widely used i n this fi old where copper tube can pl aced over the end of t he copper tube to be j d ned;the t ube end t hen serve—C ass 150,corrpl y wi t ASM E B16.24,"Cast Copper AI I oy i s fl ared out at an approxi rr ke 45 degree angl e by a fl ari rig tool.The R pe Ranges and Ranged Rtt i ngs C ass 150,300,400,600,900, 1500 flared end is then drawn up by the tube nut so the inside surface is and 250a'; and Class 125, which conform to MSS SP 106, "Cast tightly secured against the ball seat of the fitting.Thisjant can be Copper Alloy Ranges and Ranged Fittings Cass 125, 150 and 300." readily dismantled at any time and is, in effect, a type of union connection. Its use is generally restricted to soft(annealed)copper Barbed Insert Fitti ngs for Pol ybutyl ene(PB)—NIBOOoffers a tubes since hard drawn tubes would be subject to splitting when o"ete I i ne of copper barbed insert fitt i ngs for j d ni ng FB t ube.The flared(if the endswere not previously annealed).The flared ends of insert fittings are produced to the requirements of ASTM F 1380. NIBCD Flared Fittings are produced to the requirements of ASME Along with the insert fittings are copper crimp rings,which,when B16.26, "Cast Copper AI I oy Fittings for Flared Copper Tube." proper)y i nstal I ed, provi de a I eak-t i ght mechani cal j of nt.Trani t i on f i tt i ngs are avai I abl e for adapt i rig to new or exi st i rig t hreaded or Solder Joint — NIBOD pioneered the development of sok der jantends. the sokderjdnt and its application to the field of copper-tube piping. Today the solder joint is widely adopted, as evidenced by the Barbed Insert Fittingsfor PEX—NIBOOoffersa complete line of majority of cities and states that have written codes to include copper barbed insert fittingsforjaning RD(tube.The insert fittings copper tube and solder joints as desirable for general plumbing, are produced to the requirements of ASTM F1807.Along with the water I i nes,vent,stack,waste and drain I i nes,as wet I as other uses i nsert f tt i ngs are copper crk mp ri ngs,whi ch,when propel y i ristal I ed, inindustry Test i rig has shown t hat oft enthesd der jant has greater provideaIeaktightmechanicaljci nt.Transitionfitti ngs are avaiIable strength than the tubes being joined, depending upon the soldering for adapting to new or existing threaded or solder joint ends. al I cy sel ected. Whi I e t he met hod of prepari ng a sol der j d nt i s an exacting art to insureafulI strengthjant,it can be readily mastered by skilled tradesmen. It is for this reason—to insure the public of R tti ng Terms - • Abbrevi ati ons the protection afforded by properly prepared joints— that NIBOD. C Ferrate solder cup products are marketed through the reputable sources of supply to the piping trades. Important procedures for preparing a solder joint are Fig Male sol der end graphically illustrated in this catalog on page 95. F Ferrate NPTthread M Male NPFthread Brazed J of nt—This type of joint has long been used wherever and Hose Standard hose thread whenever critical situation have been encountered in copper piping. Hub Ferrate end for sal pipe Thejant itself is completed much in the same manner-as the solder joint; however,considerably more heat and several refinements of -0got Maleend for sal pipe technique require separate procedures that are descri bed further in No Hub Used with mechanical coupling this catalog on pages 96-97. CID.Tube Actual tube outside diameter S Straight thread Threaded Ends — To adapt copper- tube to equipment havkrig SJ Slipjant National Standard Rpe Taper(NM threads or to add copper tube to R Fared existing iron pipe installation or other threaded connections,NIBO) provides fittings having both external and internal NPr threads. These threaded ends are produced to the requirements of ASME 131.20.1,"R pe Threads,General Rarpose(inch)." Ranges — To adapt copper tube to equipment having flanged ® NIBOJING wgaD HEN)C.WRT9'S• 1516 MIDDL®l-R ST.• RA-PRr,IN 46516-4740• USA• R-t 1.800.234.0227 TKHSERMCFSR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAX+1.574.205.3455 www.niboaoomm NIBCCY www.nibco.com AHEAD OF • MAKES WHAT PLUM BI NG SYSTEM FAI L? Fai I ure i n a copper pl ur bi rig system i s rare,but may occur due to a vari ety ABBMMATED EM F SER E5 of reasons.The rrost oom n-on causes of fai l ure are: (eect rarotive-Farce Series,Cxrron R ng Materials i n Sea Water) CATHCDE(+)Passive 1. Excessive fIuid velocity causes erosiorroorrosionorirrpingerrent(to strike Fl Fixtures,Faucets,Rating or hit against)attack in the tube and/or fitting.For this reason,the copper SILVER—Brazing alloys,Slver-bearing solders plumbing industry has establish design velocity I i rrits for copper plumbing TITANIUM—Condenser tubes systems to the following: MCNR-(67%Ni-33%CL)—Specialty pi ping&equi prrent Hot Water>140°F(60°C) 2to3feet per second CUFFONICI<EL—Condersers,Marine,Nuclear (0.6 to 0.9 meters per second) Cam—R-essure,ENW,Gases,Air,Refrigeration,etc.BPASS(85 15-Red)—Cast fitti ngs,\ialves Fbt Water 140°F(60°C) 4 to 5 feet per second B9k9S(70130-Yel I ow)—Cos-cocks,Fitti ngs,Connectors (1.2 to 1.5 meters per second) LEAD—Solder,Rpe,meet,Coating,Lining Cold Water 5 to 8 feet per second T1 N—Sdders,Coating,Lining (1.5 to 2.4 meters per second) CAST I FCN—Ressure,DAM/ WRCLG-IT I FCN—Ressure 2. Localized high velocities and/or turbulence.The presence of a dent,tube MILDS EEL—Fire Rotection ends which are not reamed or deburred before soldering, and sudden ALLMINUvl—Fefrigeraticn,Irrigation,sareSolar changes in direction can all cause localized high velocitycanditions. GALVANIZED STEEL—Ressure,D✓W ZINC—Coatings,Linings,some Fittings 3. Flux Corrosion is typified by On hole leaks,generally in the bottom of a MACNESUv1—Water Heater Anodes,Cathodic protection forpipelires horiamtal line. Fluxes are rrildly corrosive liquid or petroleurn-based A,NCDE(-)pctive;Sacrificial Material pastes containing chlorides of anc and armnnia. Lhless the floc is flushed from the system,it will lay in the bottom of the tube and remain 5. Dee ncification is a type of corrosion in which brass dissolves as an al Ioy active.ASfMB813,"Liquid and Paste Ruxes for Soldering Applications and the copper constituent redeposits fromsdution onto the surface ofthe of Copper and Copper-Alloy Tube," limits the oorrosivity of soldering brass as a metal, but i n the porous form The anc oonstituent may be fluxes and ensures that these fluxes are flushable in cold water,which carried awayfromthe brass as a soluble salt,or n-aybedeposited in place facilitates easy removal of flux residue following installation. as an insoluble compound.Deancification is normallyassodated with 4. C�Ivanic Corrosion may be defined as the destruction of a material by brass val ves where t he a General exceeds 15%.CeralIy,areas of high electrodlemcal interaction between the environment and the material. stress,such as valve stemsarldgatevalvebodies,areprirrarytargetsof attack Generally, is slaw but persistent in d-aracter and requires the presence C of di ssi n i I ar metals. Galvanic corrosion requires the flow of an electric 6. a rare occasi on probl errs of corrosi on by aggressi ve water, possi bl y current between oertai n areas of di ssi mi I ar metal surfaces.To comp)ete aggravated by poor-desi gn or wortkrrarshi p,do ex i st.Aggressive,hard wel I the el ectricci rcuit,there must be two el ect rodes,an anode and a cat hode, waters that cause pitti rig can beidentifiedbychemi cal anal ysis and treated and they mast be connected by an electrolyte media (water)through to bringtheir composition within acceptable linits.1ypicallythese,hard which the current can pass.The amount of metal which dissolves at the waters are found to have high total dissolved solids(t.d.s.)including anode is proportional to the nurnber-of electrons flowing,which in tum is sulfates and chlorides,a pH in the range of 7.2 to 7.8,a high content of dependent upon the potential and resistance of the two metals.The use carbon dioxide(0M)gas(over 10 parts per rriI lion,ppm),and the presence of dissimilar metals in a plumbing system may or may not create a of dissolved oxygen(D.Q)gas.Soft acidic waters can cause the annoying problem For-instance, copper and steel are perhaps the most common problemof green staining of fixtures or"green water".R isingthepHof di ssi n i I ar metals found together in a pl umrbi rig system In dosed systems, such waters to a\rA ue aF about 7.2 or mole usual I y sol ves the probl ern,but such as a chilled or heating water pipi rig,the use ofdissiniIar metals may a qualified water treatment specialist should be consulted. not create a serious problem this is because there is virtually no oxygen 7 Aggressive sal conditions can be a causefor external corrosion of copper- in the water and corrosion relations tend to be stifled.Where dissimilar piping systems Non-uniform sal characteristics, such as different soil metals mast be used,some codes require that they should be separated aeration,resistivity or rrroisture properties,between adjacent sections of by dielectric union or a similar type of fitting.The effectiveness depends tube can create galvanic corrosion calls. Soils ocrltaminated with high upon; distance between the metals on the electromotive-force series concentrations of road salts or fertilizers containing ammonia,chlorides, (EMF)dart,ratio of cathode to anode area,degree of aeration,amount of and nitrogen are known to con-bine with water to form adds.Any metal agitation,temperature,presence of dissolved salts,and other factors. pipe laid i n ash or cinders is subs ect to attack bythe acid generated when sulfur compounds comrbi ne with water to form sulfuric add. U.S.aastorrary units in this doaxrerrt are the standard;the matdc units are provided fa- reference only The values stated in each system are not exact equivalents. NIBM lNG wC R D FEADC LARL9Z5. 1516 MIDaEBLW SL• EIN-Aff IN 46516-4740• USA• F}t 1.800.234.0227 THN S9RA(ES R-t 1.888.446.4226• FAX 1.800.234.055!• IN19aVAl1CIVAL S9RACE R-t+1.574.295.3221• FAX+1.574.295.3455 www ri boo.mm www.nibco.com AHEAD OF • CDWff Tube Fittiloonti nued SOLDER J•NT SPEOI ON 1. Sol deri ng Clearance(between the outside of the tube and the inside diameter of the solder cup)and the Depth of the Solder Cup(into whi ch the tube is inserted). •hart 1-Sol deri ng •earance and Sol der • • Depth r 0. Ld Norrinal Maodmxn Minimrn MaArrum Depth of SM I.D.of QD.of Qearance Solder Qjp e.0W of Ftti rig Fitting Twe fcrSddenng (Indies) inch mn Inch (mm) Inch (mm Inch mm 1/4 0.381 (9.66) 0.374 (9.50) 0.007 (0.18) 0.31 (7.9) &11� N8 0.506 (1285) 0.499 (1267) 0.007 (0.18) 038 (9.7) l tl 1/2 0.631 (16.03) 0.622 (15.85) 0.009 (0.18) 0.50 (127) 4 58 0.756 (19.20) 0.749 (19.02) 0.007 (0.18) 0.62 (15.7) 11$14> $ p R FITTINGS 3(4 0.881 (28) 0.872 (2220) 0.009 (0.18) 0.75 (19.1) •W OV sEt ALLOY R rl;;4 1 1.132 (28.75) 1.123 (28.54) 0.008 (0.216) 0.91 (23.1) 1001 11/4 1.382 (35.10) 1.373 (34.88) 0.008 (0.216) 0.97 (24.6) a 11/2 1.633 (41.48) 1.623 (41.22) 0.010 (0.25) 1.09 (27.7) 2 2.133 (54.18) 2.123 (53.92) 0.010 (0.25) 1.34 (34.0) 4111. (IT M 125 (W 21/2 2633 (66.88) 2.623 (66.62) 0.010 (0.25) 1.47 (37.3) DEPTH GF GORE.INCHES(mm? 3 3.133 (79.58) 3.123 (79.32) 0.010 (0.25) 1.66 (422) 31/2 3.633 (9228) 3.623 (9202) 0.010 (0.25) 1.91 (48.5) 4 4.133 (104.98) 4123 (104.72) 0.010 (0.25) 216 (54.9) 5 5.133 (130.38) 5.123 (130.12) 0.010 (0.25) 266 (67.6) 6 16.133 (155.78) 6.123 (155.52) 0.010 (0.25) 3.09 (18.5) TO BE + OF PROPER TOLERANCES The National QreaaofStaxlards%port8MS56,"Strength of Soft-Soldered Joints ink It is apparent that all of the scientific apparatus used to test tube Tiding,"reporting on tests oaxJudedwith3/4-inch tubing aid fitting,says°Whenthe and fittirx�s,accadir>gto the dimensions indicatedin Chart 1,would deararreisgr erthan0.010indi(0.25rrm),thereisdffialtyinfillingthejdr properly beirrlxactical to use onthejob. It is therefore essential that you install tube and fitti ngs manufactured by companies known to be 2. Depth of Solder Penetration drastically affects the breaking dedicated to the highest quality control standards.Should you load ofthejoi nt.When there is too great a soldering clearance, encounter aoorlditionwherethereisdifficultyinfillingthejoint there isnocapillary flotivto assure complete sdderperietration. property,NIBODwill analym the trouble without charge.Just send As shown i n the chart below,the holding power of the /4-inch six i nches of the tube,along with the fitting and our technicians wi I I joint is directly proportional tothedepth of solder perpetration. provide you with an authoritative report. For exarrple:If you get only orle�third penetration,you get approxi r ately ore-thi rd the strength needed to assure complete satisfaction. Chart 2-Type K 3/411 Tubing I I y '_F I. .I. Solder penetration ofor-third Sol der penetraticnof the entire the cup depth-brew ing load, cup depth-breald rig Ioad app-cAnately2,1001b.(955kg) approdrretdy7,0001b.(3175kg) U.S a stcn ary units i n thi s docurerit are the standard;the rretri c units are pro,i ded for reference oriy.7 e\d Les stated i n each system are not exad eqL ival ents. NIBMINC WCFiDFEADCLARTBS- 1516 MICD_B3L WST.- B104Wr,IN46516 4740- USA- 1`1141.80D.234.0227 TlTHSERACTBA-t1.868.446.4716- FAx1.800.234.0557- INT9aVAl1CNALSERACER-t+1.574.295.3221- FAx+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • BRAZING •' ' • ODpper Water For Estirrating FUrposes TubeSm Braang^Filler FbgJred Torch Tp AcetyleneCl3mrrption CKygen Ressure(ApRox.) AoetyieneRessure(Approx) (In Inches) Indies (rrm) DII SmNo. CFH. (CM.H) m (kFb) FS Kb) 1/4 0.258 (64) 54 15.9 (0.5) 4 (27) 4 (27) 3/8 0.386 (9.7) 54 15.9 (0.5) 4 (27) 4 (27) 1/2 0.50 12. 51 24.8 0. 5 34 5 34 518 0.52 (15.7) 51 24.8 (0.7) 5 (34) 5 (34) 3/4 1.00 (25.0) 51 24.8 (0.7) 5 (34) 5 (34) 1 1.60 41.0 48 31.6 0.9 6 41 6 41 11/4 2.00 (51.0) 48 31.6 (0.9) 6 (41) 6 (41) 11/2 2.60 (66.0) 44 38.7 (1.1) 7 (48) 7 (48) 2 4.40 112.0 40 60.0 1. 7 48 7 48 21/2 5.90 (150.0) 40 60.0 (1.7) 7 (48) 7 (48) 3 7.90 (200.0) 35 70.0 (2.0) 71/2 (52) 71/2 (52) 31/2 10.50 (207.0) 35 70.0 2.0 7/2 52 71/2 52 4 13.50 (343.0) 30 88.5 (2.5) 9 (62) 9 (62) 5 20.50 (521.0) 30 88.5 (25) 9 (62) 9 (62) 6 28.50 4.0) 30 88.5 9 62 9 62 'Appradrrate corsmoionwhen braang one ap of the fittirig.Actual amrrption depends on waivrenship. For filler sms sl awn,one pound d filler alloyprcNides 1,068 inches(27.13 nTn)of 1/16-inch wire or 475 Indies(12,065 n n)of 3/3--inch wire. B 1/leinc h(1.59 mn)Tiarrleter wire;all Other is 3/32-i rc h(2.38 n Tn)d1anmter. SOLDER AND • Nom Sze Ant Sol der F;bquired,LB(kg) (In Indies) General Use Drainage Use 1/4 0.097 - 318 0.159 - 1/2 0.261 - 518 0.389 - 314 0.548 - 1 0.856 - 1 1/4 1.115 1.2 0. 11/2 1.480 1.4 (0.6) 2 2380 1.5 (0.7) 21/2 3.225 - 3 4.335 2.8 (1.3) 31/2 5.786 - 4 7.446 4.2 (1.9) 5 11.392 - 6 15.815 - 8 26.955 - Solder recui rerrents in the table are based on estimate of weight of solder used to prepare 100 solderjolnts of sires shown. Two(2)ounoes(0.06 kg)d solderflux W ll be required for each pound(0.45 kg)of solder. U.S astorraly units in this doarnent are the standard;the metric units are provided for reference ml y The A Lies stated in each system are not exact equvalents. NIBOJ INC WCFLD FEADCLART9T• 1516 MICIAEMR(Sr• BJ qU,IN 465164740• LISA,• R-t 1.800.234.0227 Tt37-I SERACES Rc 1.888.446.4226• FAX 1.800.234.0557• IN1ff?,A-1CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 wwwriboo.omn www.nibco.com AHEAD OF • 0DWff Tube Fitti continued M ADE WI TH 00PPEIR WATER TUB E AN D SOLDER TYPE R TTI N GS, PSI (BAR) Mam mum Gauge Work ng Ressure for Standard Water Tube 92es[Note(1)] Saturated Steam WbrW rig Temperature 1/8'though V 11/4"through 2' 21/2"through 4' 61 through 91 la,to12' LB(kg) JoiringMaterial °F °C FS BAR F9 BAR PSI BAR PSI BAR P9 BAR Al 929S A]loy9n50 100 38 200 (14) 175 (12) 150 (10) 135 (9) 100 (6) 50-50TrAadsoider 150 66 150 (10) 125 (9) 100 (7) 90 (6) 70 (5) 15 [Notes(2),(3)] 200 93 100 (7) 90 (6) 75 (5) 70 (5) 50 (3) 250 121 85 6 75 5 50 3 45 3 40 3 AI Icy Sb5 100 38 1090 G) (75) 850)8) (59) 705)9) (49) 660(8) (46) 340 (23) 150 66 52500) (43) 485)10) (34) 405)10) (28)— 37500) (26,)--280 (19) 95-5TrrAntimrmysdder 15 [Note(4)] 200 93 50511) (35) 395)10) (27) 32511) (32) 305110) (21) 230 (16) 250 121 270 19 210 15 175 12 165 11 120 8 100 38 71010) (`9) 555 10) (38) 46010) (32) 43000) (30) 320 (22) AJIoyE 150 66 475)11) (33) 37000) (26) 30510) (21) 285111) (20) 215 (15) 15 200 93 375 (26) 290 (20) 240") (17) 22501) (16) 170 (12) 250 121 320 (22) 250 (17) 205 (14) 195 (13) 145 (9) AIIoy I-B 100 38 1035 0) (71) 805)8) (56) 670(8) (46) 625(9r (43) 340 (23) [Note(6)] 150 66 71010, (49) 555)10) (38) 46010) (32) 430[901 (30) 320 (22) 15 200 93 44011) (30) 345)11) (24) 285 111 (20) 265(11) (18) 200 (14) 250 121 43011) (30) 335)1) (23) 27511) (19) 26Y) (18) 195 (13) Joi ning r aterialsat or above 593°C Ressure-temperature ratings consi stent with the materials and procedures employed. [Note(7)] CENB:;PLNOTE For extremely low waiting temperatures in the CW Fto 200°Frange,it is reomnended that ajol nt material meting at or above 1000°Fbe employed[see Note(5)]. NOTES (1) Standard water tube sims per PSTMB88 (2) ASTTVIB32Alloy(3-adeSn50 (3) The Safe Dn nla ng Water Pct A-end7ent of 1986 prohibits the use of arty solder havi ng a lead content in excess of 0.2%in potable water systems. (4) ASTMB32Alloy(-adeSb5 (5) ASTM B 32 Alloy(3ade E (6) ASTMB32Alloy(3-adeFB (7 Thesejdningmatedals are definedas&ra gdloysby the American Weld ngSociety. (8) TiesdderjointexceedsthestrergthofTypesKL&Mtubeindawnarndanr>ealedtempers. (9) ThesdderjdntexceedsthestrengthofTjpesL&MtubeindrawntemperandTypeKtubeinanr>ealedterpe: (10) The solderjcint exceeds the strength of Type M tube i n dawn teryper and Types L&K i n annealed temper. (11) Tie sd der jcint exceeds the strength of Type L tube in anneal edterrper MADE WITH FLAFED RTI1 NGS AND OOPPER WATP TUBE PaYBUTYLENE TUBE AND a)PPER BARBED I NSE1R`F FITTI NGS Nominal Sze Joint Nominal Sze Joint (In Inches) Temperature,°FCQI Ressure,PSI(1341;�' (In Inches) Temperature,'FCC) Ressure,PSI Wl� N8,1/2,314,1, 318,1/2,3/4,1 73 (23) 200 (14) 11/4,11/2,2 100 (38) 175 (12) 140 (60) 160 (11) "ASMEB16.26 180 (82) 100 m 200 (93) 1 80 (5) U.S.arstcmary units inthis document arethestandard;themEtricunitsareprovidedfar reference only The values stated in each system are not exact equ\rAents © NIBDJINC:WCRDH15N)a14RTffS- 1516MIDDL63J;YST.• BJ4-NUIN46516-4740• US4• R-t1.800.234.0227 ■ TKH SBRACE5 Rt 1.888.446.4226• FAX 1.800.234.0557• INTBaJA-nC NAL SERAC E R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.00m NIBCCY www.nibco.com AHEAD OF • RATED I NTB:NALWOFNNGPFESSUFE FOR COPPER FITTINGS, PSI (BAR) Water Temperature Rle Nom no]Water Tube 5m -20°to 100°F 150°F 200°F 250°F 300°F 35D°F 400'F (In Indies) (29°to38°C) (66°C) WC) (120°C) (149°0 (177°G) (2D4°C) 1/4 912 (62) 775 (53) 729 (50) 729 (50) 714 (49) 608 (42) 456 (31) 3/8 779 (54) 662 (46) 623 (43) 623 (43) 610 (42) 519 (36) 389 (27) 1/2 722 50 613 42 577 40 577 40 565 39 481 33 361 (25 5(8 631 (43) 537 (37) 505 (35) 505 (35) 495 (34) 421 (29) 316 (21) S4 582 (40) 495 (34) 466 (32) 466 (32) 456 (31) 388 (27) 291 (20) 1 494 34 420 29 395 395 397 25 330 23 247 1 11/4 439 (30) 373 (26) 351 (24) 351 (24) 344 (23) 293 (20) 219 (15) 11/2 408 (28) 347 (24) 327 (23) 327 (23) 320 (22) 272 (19) 204 (14) 2 364 ( 309 (21) 291 (20) 291 20 285 20 242 1 182 13 21/2 336 (23) 285 (20) 269 (19) 269 (19) 263 (18) 224 (15) 168 (12) 3 317 (22) 270 (19) 254 (17) 254 (17) 248 (17) 211 (15) 159 (11) 31/2 304 21 258 18 243 (17) 243 (17) 238 16 202 14 152 10 4 293 (20) 249 (17) 235 (16) 235 (16) 230 (16) 196 (13) 147 (10) 5 269 (19) 229 (16) 215 (15) 215 (15) 211 (15) 179 (12) 135 (9) 6 251 1 213 15 201 14 201 14 196 14 167 12 125 8 8 270 (19) 230 (16) 216 (15) 216 (15) 212 (15) 18D (12) 135 (9) Thefitting p ws re rating appliestothe largest opening of thefitting. -A :D I NTEFNAL •:M NG PFESSURES OF CAST COPPER ALLOY FLANGES AND FLANGED R Tn NGS Ressu-e(P51) Nominal Szq Joint Temperature (In Indies) 'FCC)' Class 125" (lass 1508 (lass 1501,1 1/2,3t4,1,11/4, 0-150 (0-66) 105 (7) 210 (14) 225 (15) 1 1/2, 2,21/2, 175 100 205 14 220 15 3,4,5,6,8 200 (93) 95 (7) 195 (13) 210 (15) (also1Cf'for 225 (107) 90 (6) 190 (13) 205 (14) Class 125) 250 121 90 6 180 12 195 13 275 (135) 85 (6) 175 (12) 190 (13) 300 (149) 85 (6) 170 (12) 180 (12) 350 (177) 75 (5) 150 (10) 165 (11) 406 (208) 70 (5) 140 (9) 150 (10) ^MSSSIZ106 aASTM B584,LNS C8' W and LUIS 0844W IASTM B62,LNS QMW and ASTM B584,LNSM3600 US customary units in this doa rrent are the staxla-d;the metdc units are proaded for reference criy The values stated in each system are riot exact egtivdents. NIBOJING WCRD FEADCJ14RT9T• 1516 MICIAEBL (Sr.• BJ44gU,IN 465164740• USA• R-t 1.800.234.0227 m TBaiSERACESR-t 1.888.446.4226- FAX 1.800.234.0557• INTB+Al1CNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 www.riboo.00m www.nibco.com AHEAD OF • q_ W_ Wder Tube The rnechanicsof rrek rig both the Sol der joint and the braangjant are oorl Wativelysirrilar.Complete instructions on proper techniques of both of these joi ni rig methods are outlined in this catalog on pages 85-97. Avery i rrportant oonsi derati on i n Copper R pi ng is the selection of the proper bondi ng rredi um Asa general rule,the world ng temperature of the installation is a more important consideration than the working pressures.If the working temperature is not over 250°F(121°G),either 50-501/o*or 95-5 1/osolder can be used successfully I Dwever,if the temperatureexoeeds250°F(121°G),alow temperature bras ng al l oy should be used,with a melting temperature somewhat in excess of 1000°F(538°C). According to BMS report No.58,joi nts made with tin or tin-alloy solders should not be subject continuously to temperatures above 250°F(121°G). A numtcer of brazing alloys are available and a careful study should be made in every case to detemi ne the proper al Ioyfor the particular application. 'The Safe Dn nla ng Water Act A m9nd rent of 1986 prohi bits the use in potable water system of any solder ham ng a lead content in excess of 0.21/o. DIMENSIONAL DATA-SOLDER JOINT Sd der Jdnt Fittings-Tol erances SdderJdnt Fittings SdderJdnt Fittings Copper AJloy-Ressare,2 CopperAlloy-Drainage" Male End(Fitting Connector) Female End(Solder Cup) Nominal Diameter Diarreter Fitting End length Solder Cup length Fitting End Length Sider Cup Length Water Tube Min. Max Min. Max Min. Min. Min. Min. 9zE)(In Indies) Inch (rrm) Inch (mm) Inch (rrm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) 1/8 0.248 (6.30) 0.251 (638) 0.252 (6.40) 0.256 (650) 0.31 (7.9) 0.25 (6.4) NA NA NA NA 1/4 0.373 (9.47) 0.376 (9.55) 0.377 (9.58) 0.381 (9.68) 0.38 (9.7) 0.31 (7.9) NA NA NYA NYA 318 0.497 (1262) 0.501 (1273) 052 (1275) 0.506 (1285) 044 (11.2) 0.38 (9.7) NA NA NA N/A 1/2 0.622 (15.80) 0.626 (15.90) 0.627 (15.93) 0.631 (16.03) 0.56 (14.2) 0.50 (127) NA NA NA NA 518 0.747 (18.97) 0.751 (19.08) 0.752 (19.10) 0.756 (19.20) 0.69 (17.5) 0.62 (15.7) NA NA NYA N/A 314 0.872 022.15) 0.876 (22.25) 0.877 (22.28) 0.881 022.38) 081 (0.6) 0.75 (19.1) NA NA NYA N/A 1 1.172 (18.50) 1.127 (26.63) 1.128 (28.66) 1.132 (28.75) 0.97 (24.6) 0.91 C&1) NVA NA NYA NYA 11/4 1.372 (34.85) 1.377 (34.98) 1.378 (35.00) 1.382 (35.10) 1.03 (262) 0.97 (24.6) 0.56 (14.2) 0.50 (127) 11/2 1.621 (41.17) 1.527 (41.33) 1.628 (41.35) 1.633 (41.48) 1.16 (29.5) 1.09 (27.7) 0.62 (15.7) 0.56 (14.2) 2 2121 (53.87) 2127 (54.03) 2128 (54.05) 2133 (54.18) 1.41 (35.8) 1.34 (34.0) 0.69 (175) 0.62 (15.7) 21/2 2621 (66.57) 2627 (66.73) 26M (66.75) 2633 (66.88) 1.53 (38.9) 1.47 (37.3) NA NA NYA N/A 3 3.121 (7927) 3.127 (79.43) 3128 (79.45) 3133 (79.58) 1.72 (43.7) 1.66 (422) 0.81 (20.6) 0.75 (19.1) 31/2 3 621 (91.97) 3.627 (92.13) 3.628 (92.15) 3633 (92.28) 1.97 (50.0) 1.91 (48.5) NA NA NA N/A 4 4.121 (104.67) 4.127 (104.83) 4.128 (104.85) 4.133 (104.98) 222 (56.4) 216 (54.9) 1.06 (16.9) 1.00 (254) 5 5.121 (130.07) 5127 (130.23) 5128 (13025) 5.133 (130.38) 272 (69.1) 266 (67.6) 1.31 (33.3) 1.25 (31.8) 6 6.121 (155.47) 6.127 (155.63) 6.128 (15565) 3133 (79.58) 322 (81.8) 309 (78.5) 1.62 (41.1) 1.50 (38.1) 8 8119 (206.22) 8.127 (206.43) 8.128 (206.45) 8.133 (206.58) 4.09 (103.9) 3.97 (100.8) 212 (53.8) 200 (50.8) 10 10.119 (257.02) 10.127 (257.23) 10.128 (257.25) 10.133 (27.38) 4.12 (104.6) 4.00 (101.6) NA NA NYA N/A 12 12119 (307.82) 12127 (308.03) 12.128 (308.05) 12.133 (308.18) 4.62 (117.3) 4.50 (114.3) "A NA NYA N/A As sham Standard ASMEB16.18 As shown Standard A%AEB16.22 As shave Standard ASMEB16.23 °As Shawn Standard ASMEB16.29 U.S.customary units i n this docun al are the standard;the metric units are provided for reference only The val ues stated in each systemare not exact equivalents. NIBOJINC WCRDFEADCLARf9s• 15161VIICD_B3UWSr• BJ04WT,IN46516-1740• USA- F114 1.80D.234.0227 • TEH SERACTB Rt 1.8B8.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574295.3455 vwvw.riboo.com NIBCCY www.nibco.com AHEAD OF • DIMENSIONAL DATA-BRAZING Male Sid(Fitting ODnnector)Diarneter Fie End(B-aang Cup)Diarreter Ftting Eid Solder Oup Length Length Nominal Min. Max. Min. Max. Min. Min. Water Tube Sm(In Ind-es) Yeti (mm) Inch (mm) Inch (mm) Inch (rrm) Inch (nm) Ind, (nm) 1/4 0.373 (9.47) 0.376 (9.55) 0.377 (9.58) 0.381 (9.68) 0.23 (5.8) 0.17 (4.3) 318 0.497 (1262) 0.501 (1273) 0.502 (1275) 0.506 (1285) 0.26 (6.6) 0.20 (5.1) 1/2 (1622 (158D) (1626 (15.90) 0.627 (15.93) 0.631 (16.03) 0.28 V.1) (122 (5.6) 5r8 0.747 (11197) 0751 (19.08) 0.752 (19.10) 0.756 (19.20) RYA RYA NA NA 3(4 0.872 (71.15) 0.876 (22.25) (1877 X2.28) 0.881 (22.38) 0.31 (79) 0.25 (64) 1 1.122 (28:50) 1.127 (28.63) 1.128 (26.65) 1.132 (28.75) 0.34 (8.6) 0.28 (7.1) 11/4 1.372 (34.85) 1.377 (34.98) 1.378 (96.00) 1.382 (35.10) 0.37 (9.4) 0.31 (7.9) 11/2 1.621 (41.17) 1.627 (41.33) 1.628 (41.35) 1.633 (41.48) 0.40 (102) 0.34 (8.6) 2 2121 (53.87) 2127 (54.03) 2128 (54.05) 2133 (54.18) 0.47 (11.9) 0.40 (10.2) 21/2 2621 ((6.57) 2627 (66.73) 2628 (66.75) 2633 (66.88) 0.53 (135) 0.47 (11.9) 3 3121 (79.27) 3.127 (79.43) 3.128 (79.45) 3.133 (79.58) 0.59 (150) (153 (13.5) 31/2 3621 (91.97) 3627 (92.13) 3.628 (92.15) 3633 (92.28) 0.65 (16.5) 0.59 (15.0) 4 4.121 (104.67) 4.127 (104.83) 4.128 (104.85) 4.133 (104.98) 0.72 (183) (164 (16.3) 5 5121 (130.07) 5127 (130.23) 5123 (13D.25) 5133 (130.38) 0.81 (20.6) (173 (18.5) 6 6.121 (155.47) 6.127 (155.63) 6.128 (155.65) 3.133 (79.58) 0.94 (2ag) 0.83 (21.1) 8 8.119 (206.22) 8127 (206.43) 8128 (206.45) 8133 (206.58) 1.28 (32.5) 1.17 (29.7) 10 10.119 (257.02) 10.127 (257.23) 10.128 (257.25) 10.133 (257.38) NA MA RYA RYA 12 12119 (307.82) 12.127 (308.03) 12.128 (308.05) 12133 (308.18) N/A N/A N/A N/A 'In acoadance with MS SP-73 U.S c stomay units in this document are the standard;the metric units are provi ded for reference cnl y the values stated in each system are not exad equvalents. NIBOJING WCRD FEADCLART9T• 1516 MIDIAEBL. (Sr• BJ44gU,IN 465164740• LISA,• R-t 1.800.234.0227 TEHSERACEBPR 1.888.446.4226• FAX 1.800.234.0557• IN1T33Vr-flCNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboo.00m www.nibco.com AHEAD OF • ODWff Water Tubeoont i nued DIMENSIONAL DATA ... , ; TYFE"K' Hard Drawn: 20-ft.(6.1m)Straight Lengths Soft Annealed: 20-ft.(6.1m)Straight Lengths,or40-ft.(12.2m)and 60-ft.(18.3m)Length 0JIs(to and including size 11/2) Usage: Far u idergrou d servi ce and general purpose pl urn i ng and heatirig instal Iations.under sere cord tions. Tolerances Hard Drawn Soft Annealed (Hard Drawn Qtly) CUtsi de Tuhi ng CD Nom nol WA I Weight Bursting Safe World ng Bursting Safe World ng Nominal Diameter Thidmess F2r Foot RessureA FressureB Ressure" Ressure� Water Tube Min. Max Si2e(In Inches) Irich (mm) Inch (mm) Inch (mm) Irich (mm) Lb (kg) psi (bars) psi (bars) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.035 (0.89) 0.145 (0.07) NA N/A 1612 (111) N/A N/A 913 (63) 318 0.500 (1270) 0.497 (1262) 0501 (1273) 0.049 (1.24) 0.269 (0.12) NA MA 1675 (115) RYA INVA 960 (66) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.049 (124) 0.344 (0.16) 9840 (678) 1337 (92) 4535 (313) 758 (52) 518 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.049 (124) 0.418 (0.19) N/A NA 1104 (76) RYA NA 626 (43) 314 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.065 (1.65) 0.641 (0.29) 9300 (641) 1278 (88) 4200 (290) 724 (50) 1 1.125 (28.58) 1.122 (21150) 1.127 (28.63) 0.065 (1.65) 0.839 (0.38) 7200 (496) 982 (68) 3415 557 (38) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.065 (1.65) 1.040 (0.47) 5525 (381) 797 (55) 28M (193) 452 (31) 11/2 1.625 (410) 1.621 (41.17) 1.627 (41.33) 0.072 (1.83) 1.36D (0.62) 5000 (345) 742 (51) 2600 (179) 420 (29) 2 2125 (53.98) 2121 (53.87) 2127 (54.03) 0.083 (211) 2060 (0.93) 3915 (270) 652 (45) 2235 (154) 370 (25) 21/2 2625 (66.68) 2621 (66.57) 2627 (66.73) 0.095 (241) 29130 (1.33) 3575 (246) 597 (41) RYA INVA 338 (23) 3 3 125 (79.38) 3.121 (7927) 3.127 (79.43) 0.109 (277) 4.000 (1.81) 3450 (236) 578 (40) NA NA 328 (13) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (9213) 0.120 (3.05) 5.120 (232) N/A NA 549 (38) RYA NA 311 (21) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.134 (3.40) 6.510 (295) 3415 M 540 (37) RYA NA 306 (21) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.160 (4.06) 9.670 (4.39) 3686 (247) 517 (36) RYA INVA 293 (20) 6 6.125 (155.58) 8121 (155.47) 6.127 (155.63) 0.192 (4.88) 13.900 (6.30) 3425 (236) 520 (36) RYA RYA 295 (20) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.271 (6.88) 25.900 (11.75) 3635 (251) 553 (38) RYA NA 314 (22) 10 10.125 (157.18) 10.119 (257.02) 10.127 (257.23) 0.338 (8.59) 40.300 (18.28) WA NA 553 (38) "A "A 314 (22) 12 12125 (307.98) 12119 (307.82) 12127 (308.03) 0.405 (10.29) 57.800 (26.22) N/A NA 555 (38) N/A N/A 314 (22) Note:Infarrrdion and data oortai red inthese chats,as taken from ASTM Specifications B86 Fbted irtemal pressure for copper water tube used on the strength of the tube alone and applicableto systems usirg suitable rrerhaicd joi nts. A Based on actual Iaboratoy test data presided by Cbpper Developrrent Assodation,Inc 6 Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668ldaa) cBased upon IWF(65.6 C)with an allowable stress of 5100 psi(359 kPa) U.Sc storaryunitsinthisdocum3ntarethestandard;themetri cunitsareplo,idedfor reference oriy.The\d Lies stated i n each system are not exari e u\d ents. NIBMINC WCRDFEADCLART9s• 1516MICD-BBLWST.• BJ04WT,IN46516-1740• LISA- R4 1.80D.234.0227 TEH SERACEB Rt 1.888.446.4226• FAX 1.800.234.0557• INTB:?VAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • eAsion 5/14/02 DI M ENSI• COPPER TYFE"L" Hard Dawn: 20•ft.(6.1m)StreightLengths Soft Annealed: 2D-ft.(6.1m)Straight Lengths,or40-ft.(12.2m)and 60-ft.(18.3m)Length(bits(to and ird udi ng si2a 1 1/2) Usage: Fbr general pupose0urrb rig and heati rig mriditions. Tderanaes Hard Drawn Soft Annealed (Ft3rd Drawn Chly) Outside Tubing CD NorrinalWall Weight Busting cleWorldng Buusting -We Working Norrinal aarreter lhidaiess FbrFoot Pressure" FFess<aeg FtessureA Ftessure WffierTube Min. Mau Son On Inches) Inch (mm) Inch (mm) Inch (mn) Inch (mn) Lb (k9) psi @ws) psi (bars) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.03D (0.76) 0.126 (0.06) N/A N/A 1357 (94) N/A N/A 775 (53) 3r8 a50D (1270) 0.497 (1262) 0.501 (1273) 0.035 (0.89) 0.198 (0.09) N/A N/A 1168 (81) N/A N/A 6132 (46) 1/2 0.625 (15.88) 0.622 (1580) 0.625 (15.90) 0.040 (1.02) 0.285 (a 13) 7765 (535) 1082 (75) 3865 (268) 613 (42) 5r8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.042 (1.07) 0.362 (0.16) N/A N/A 947 (65) N/A MA 537 p 3(4 0.875 (2223) 0.872 (2215) 0.876 (2227) 0.045 (1.14) 0.455 (0.21) 5900 (407) 873 (6D) 2935 (202) 495 (34) 1 1.125 (28.53) 1.122 (28.50) 1.127 (28.63) 0.050 (1.27) 0.655 (0.30) 5115 (353) 741 (51) 26.50 (183) 420 (29) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.96) 0.055 (1.40) 0.884 (0.40) 4560 (314) 658 (45) 2400 (165) 373 (6) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.060 (1.52) 1.140 (0.52) 410D (283) 613 (42) 2200 (152) 347 (24) 2 2125 (53.98) 2121 (5387) 2127 (54.03) 0.070 (1.78) 1.750 (0.79) 3365 (232) 545 (38) 1910 (132) 309 0) 21/2 2625 (6668) 2621 (66.57) 2627 (66.73) 0.08D (203) 2480 (1.12) 3215 (222) 5D4 (35) N/A N/A 285 (20) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.090 (229) 3330 (1.51) 2865 (198) 476 (33) N/A N/A 270 (19) 31/2 3.625 (92.06) 3.621 (91.97) 3.627 (92.13) 0.100 (254) 4:290 (1.95) MA N/A 455 (31) N/A MA 258 (18) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.110 (279) 5380 (244) 2865 (196) 440 (30) N/A N/A 249 (17) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.125 (3.18) 7.610 (345) 2985 (206) 404 (28) N/A N/A 229 (16) 6 6.125 (156.58) 6.121 (15647) 11127 (155.63) 0.140 (3.56) 10200 (4.63) 2690 (185) 376 (26) N/A N/A 213 (15) 8 8.125 (206.38) 8.119 (206.22) 11127 (206.43) 02DO (508) 19.290 (8.75) 2650 (183) 406 (28) N/A MA 230 (16) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0250 (6.35) 30.100 (13.65) N/A N/A 407 (28) N/A N/A 231 (16) 12 12125 (37798) 12119 (307.82) 12127 (308.03) 0280 (1.11) 40.400 (11133) N/A N/A 380 (26) N/A N/A 215 (15) Note:Irfomredion and data contained in these ducts,as taken franABTM Specifications 1388. Rted i nternal pressure for eoper water tube based on the strength of the tube alone and app icabletosystems usng suitable rrechanid joints. "Based on actual laboratory test data provided byQ)pper DeAeloprrent Association,Inc. e Based upon 150°F(65.6°C)with an aI IoNable stress of 9500 psi(668 nP used upon 150°F(65.G'C)with an allowable stress of 5100 psi(359 kPa} U.S customary units in this dca rnent are the stanclard;the metric units are provi ded for reference only the values stated in each system are not e)od equivalents. NIBOJINGWCRDFEADCLART9T• 1516 MI0M83Lk'2i'Sr• BJ44gUIN465164740• L1S4• R-t1.800.234.0227 TEHSBRACESPH 1.888.446.4226• FAX 1.800.234.0557• IN1T33V1-flCNALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 wwwriboo.00m www.nibco.com AHEAD OF • ODWff Water Tubeoont i nued DIMENSIONAL DATA ... , ; TYFE"M° Hard Drawn Only 20ft.(6.1m)Straight Lengths Lbage. For gc e al purpose pl unb ng,heati ng and drainage installations. Tolerances Hard Drawn (Hard Drawn Qtly) Cutside TubingCID Nominal Wed Weight Birsting Safe Work ng Nominal Diarreter 'Thickness Per Fbot RessureA RessureB Water Tube Min. Max Sar(In lndies) Inch (mm) Inch (mm) Ind, (nTn) Ind, (mm) Lb (kg) ps (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) NA NA NVA NA N/A NA NA INYA 318 0.500 (1270) 0.497 (1262) 0.501 (1273) 0025 (0.64) 0.145 (0.07) NA RYA 855 (59) 1/2 0.625 (15.88) 0.671' (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 518 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) RYA IVA NA NIA RYA RYA NA NA 314 0.875 (72.23) 0.872 (22.15) 0.876 X2.25) 0032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 018.63) 0035 (0.89) 0.465 (0.21) 3865 (266) 506 05) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0042 (1.07) 0.682 (0.31) 3875 (267) 507 11/2 1.625 (410) 1.621 (41.17) 1.627 (41.33) 0.019 (1.24) 0.940 (0.43) 3560 (245) 497 (34) 2 2125 (53.98) 2121 (53.87) 2127 (54.03) 0058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2625 (66.68) 2621 (66.57) 2627 (66.73) 0065 (1.65) 2030 (0.92) 2800 (193) 411 (18) 3 3.125 (79.38) 3.121 (7927) 3.127 (79.43) 0072 (1.83) 2680 (1.22) 26F3 (184) 380 (25) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (9213) 0.063 (211) 3.580 (1.62) RYA NA 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0095 (241) 4.660 (211) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0109 (277) 6.660 (3.02) 2490 (172) 349 (14) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0122 (3.10) am (4.05) 200D (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (1.48) 2186 (158) 344 94) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) NA NA 344 (24) 12 12125 (307.98) 12119 (307.82) 12127 (308.03) 0.254 (6.45) 36.700 (16.65) NA N/A 345 (24) Note:Infamy ion and data cortaired inthese chats,as taken from ASTM Specifi cations B86 R ted internal pressure for copper water tube used on the strength of the tube atone and applicableto systems using suitable machaical joi nts. A Based on actual Iaboratay test data presided by Q)pper Dedoprrent Assodation,Inc 6 Based upon 150°F(65.6oQ with an allowable stress of 9500 psi(668ldaa) U.S o rstorr ay nits i n t s docurrent are the standard;the metri c units are pravi ded for reference criy.1he values stated in each systemare not exact equvakents. NIBMINC WCRDFEADCLARTBS• 1516MIDD03BLWSL• 13104 Rf,IN46516-1740• LISA- R4 1.80D.234.0227 1T37-ISERACEBA-t 1.888.446.4226• FAX 1.800.234.0557• INTB:?d Al1CNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • TYFE°Ck W' Hard Drawrialy 20-ft.(6.1m)Straight Lengths Usage: Fordrain,waste,vent and other nonrpressureapplications. Tderanoes Hard Drawn (-lard Drawn Only) D M/Tube is for sanitary drai wage Oitside Tubing CD Nominal WAI Weight l3rsting applicatiorns.Thetubngwallisthinnerthan Nordnal Dameter Thidv>ess FbrFoot Ffessue" Type"M"-madng it both lighter and less Water Tube Min. Max a ve.Pesearch indicates that CkWtube Size(In lnChes) Inch (rrrn) Inch (rrm) Inch (mm) Inch (mm) Lb (kg) psi (bars) has a servi oe I ife of approxi mately 100 years- 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) NIA N/A N/A NA N/A NIA 00nsi derablyIonger than anybuildi rig inwhich 3/8 0.500 (1270) 0.497 (1262) 0.501 (1273) NA N/A NA NA N/A NA it might be installed. 1/2 0.625 (15.88) 0.671 (15.80) 0.625 (15.90) N/A N/A NA NIA NA NA The advantages of ooh systems are 518 0.750 19. 0.747 18 0.751 19.08 NIA RYA NA NA NA NIA augmented npke l7JWirgandtions.Iortatit ( � ( � ( ) weightrrt 3kesharidlingaridtransportation 3(4 0.875 (2223) 0.872 (2215) 0.876 (71.25) N/A NA NA NA NA NA easier-only 0.34 lb.(0.15 kg)far a 20 ft.(6.1 1 1.125 (28.53) 1.122 (28.50) 1.127 (28.63) NA N/A NA NA MA NA m)length solde si�3.Its thinner wall allows faster sddering. 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.040 (1.02) 0.650 (0.29) NA NYA These 11/2 1.625 41.28 1.621 41.1 1.627 41.33 0.042 1. 0.809 0. 440 30 Theo ��' �aneoorroncal option ( ) ( �1 ( ) ( � ( � ( ) withoutsaaifiangstabilityorlaigevityfor 2 2125 (53.98) 2121 (53.87) 2127 (54.03) 0.042 (1.07) 1.070 (0.49) 326 (22) both cortracto-and the home owner.I Lither 21/2 2625 (6668) 2621 (66.57) 2627 (66.73) NA N/A NA NYA N/A N/A information Tech ill l Sarvioes Deln request ent,at NI60C7sTechrtical Services Ckpartment,at 3 3.125 (79.3B) 3.121 (79.27) 3.127 (79.43) 0.045 (1.14) 1.690 (0.77) 239 (16) 1488.446226 31/2 3.625 (92.06) 3.621 (91.97) 3.627 (92.13) NIA N/A NA NYA NIA MA 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.058 (1.47) 2870 (1.30) 225 (16) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.072 (1.83) 4.430 (201) 227 (16) 6 6.125 (15653) 6.121 (15647) 6127 (155.63) 0.083 (211) 6100 (277) 223 (15) 8 8.125 00638) 8.119 (20622) 8.127 (206.43) 0.109 N/A 10600 (4.81) 219 (15) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) N/A NA NA NA NA NA 12 12125 (30798) 12119 (307.82) 12127 (308.03) N/A N/A N/A NA NA N/A Note:Irfomredion and data contai ned in these darts,as takenfranASTM gmcifirations B88. Ftedinten-d pressure for oopper water tWe based on the strength of the trbealone" app icadetosysterrs us rig suitable mechanical joints. "Based on actual laboratory test data provided by Qpper Developrrent Association,Inc e Based upon 150°F(65.6°C)with an al IoNable stress of 9500 psi(668 nP Based upon 150°F(65.6'C)Wth an allowablestress of 5100 psi(359 kPa} U.S.customary units in this doarrerrt are the standard;the metric units are provided for reference only The values stated in each system are not exact equivalents NIBO)ING WCRD FEADCLART9T• 1516 MICM83J'2i'Sr• BJ44gU IN 465164740• US4• R-t 1.800.234.0227 TEH SBRACES Ftt 1.888.446.4226• FAX 1.800.234.0557• IN193VrIIlCNALSERACE R-t+1.574.295.3221• FAX-+1.574295.3455 wwwniboo.mrn www.nibco.com AHEAD OF • CoWer Water Tubelciont i nued Under nwTd conditions,the physical properties of copper tubes,when produced by responsible m enufacturers are perfectly adapted for the conveyance of hot and ool d water,steam,a I,gas,and air.Copper tubes will stand up under ordi nary conditions,but the user is spedficallycautioned against laying underground tube in dnderfiII,especially if the ground is apt to be wet. Due to the sulphur compounds i n the cinders,a condition of this land may corrode the outside of the tubes.This may be overcome ei t her by wrappi rig the tube with canvas and asphaltum or by surrounding the tube with abed of dean sand nixed with lime,or with limestone or broken plaster.When conditions are doubtful, it is advisable to consult the Copper Development Assodation,or the tube manufacturer. Annealed copper tubes are generally recce mended for underground use.'/2"annealed copper tubes have been frozen as many as six times before finally bursti rig,eight times for 1"size,and el even times for 2'size.Hard drawn copper tubes,however,burst during the f i rst f reea ng the same as i ron pi pe.(Condensed from Copper Tube Handbook) COM PARATI VE DATA-COPPER WATER TUBE AND I RON PI PES BTUsto Fbse 100°F138°C Noninal „A, „B, „C, D' E, „F "G' „H, T' Water New Rpe Inside CUtside Weight \blume Water Rpe Had Loss Raw Tubegm Demeter Diameter (In Indies) Inch (mm) [rich (mm) Lb (Kg) Cd/loft. uao5m BTU kJ BTU M BTU kJ GM LR A 38 QI- .430 (10.92) 0500 (1270) 0.198 (0.090) 0.0754 (0.2854) 6289 ((64) 1861 (19.6) NDDzta %Na 1.873 (1.089) Iran .498 (1252) 0.675 (17.15) 0.567 (0.257) 0.0992 (0.3756) x266 (87.2) 6237 (85.8) NoDAa KbNa 2464 (9.325) 1/2 04- .545 (1384) 0.525 (15.86) a285 (0.129) 0.1212 (0.4587) 10120 (106.8) 2670 (182) 0.34 (0.36) 3565 (13494) Iran .622 (1580) 0.840 (21.34) 0.850 (0.386) 0.1578 (0.5973) 131.60 (1388) 93.50 (9116) 593 (627) 4.585 (17.354) 3(4 04- .785 (1994). 0.875 WZ) 0.455 (0.207) (12514 (0.9515) 209.60 (221.1) 4267 (45.0) 0.41 (0.44) 9.599 06332) Iran .824 (2D.93) 1.050 x.67) 1.130 (0.513) 0.2770 (1.0984) 23010 (2428) 120D (131.1) 7.16 (7.56) 9727 (r.79D) 1 QW 1.025 X6.04) 1.125 (2858) 0.655 (0.297) 0.4287 (1.6226) 357.30 (377.0) 61.38 (64.8) 050 (0.53) 19.80 (74.94) Iran 1.049 (2a64) 1.315 (33.40) 1.678 (0.762) 0.4490 (1.6995) 374.30 (384.9) 184.58 (199.7) 862 (9.09) 1853 (70.14) 11/4 OW 105 0213) 1.375 (34.93) 0.864 (0.401) 0.6629 (24712) 544.3D (574.3) 8291 (87.5) 062 (0.65) 35.05 (13266) Iran 1.38D (J605) 1.680 (4216) 2270 (1.031) 0.7770 (29909) 647.70 (68a4) 24970 (261.4) 10.65 (11.24) 3856 (14595) 11/2 Qw 1.505 (38.23) 1.625 (41.28) 1.140 (0.518) 0.9241 (34977) 77640 (8128) 107.16 (1131) 0.69 (0.73) 5616 (21257) Iran 1.610 (40.89) 1.900 (4826) 2729 (1.235) 1.0580 (4.0095) 881.60 (930.1) 29810 (314.5) 11.97 (1263) %m X2a29) 2 Qua' 1.985 (50.42) 2125 (5398) 1.750 (0.795) 1.6060 (6.0863) 1340.0D (14138) 164.50 (1736) 084 (0.89) 119.10 (45079) Iran 2067 (5250) 2375 (60.33) 3650 (1.657) 1.7430 (6.5973) 1453.oD (15330) 401.50 (423.6) 14.61 (1541) 11350 (429.60) 21/2 C4- 2465 (6261) 2625 (66.68) 2480 (1.126) 24790 (9.3830) MOD (2179.7) 23300 (1458) 1.01 (1.07) 21430 (811.13) Iran 2469 6271) 2875 (73.08) 5.790 (2629) 24870 (9.4133) 20730D (2187.1) 631190 (6720) 17.42 (1838) 18250 (69076) 3 OW 2945 (74.80) 3125 (79.38) 3330 (1.512) 35390 (13.3951) 2945oD (31071) 313x7 MA) 1.13 (1.19) 347.40 (1314.91) Iran 3068 (77.98) 35 (889D) 7.55 (3441) 38400 (14.5344) 32D1.OD (3377.2) 83270 (878.5) 20.63 (21.77) 3M.00 (1233.91 4 aw 3.905 (99.19) 4.125 (10478) 5380 (2443) 6.2220 (2:!.5M3) 51860D (5471.5) 50571 (5336) 1.50 (1.59) 74710 X82777) Iran 4.026 (10226) 4.5 (114.3D) 1079 (4.899) 66130 (25.0002) 551300 (5816.5) 1186.90 (12522) 260D (27.43) 67a80 (2550.33) OaJJMN A The copper tube is Type LStaindard,meeting the requirements of ASiM OaLMN Ft'ihisodu nshaystheheat errissicnfrcm1Ofeet(3.05 n-dres)of thegiven Specification B88.The iron pipe is standard weight,schedule 40,bare pipe,ecept as tube and pipe placed hcrimntally.The column in tears of BTUs lost per hour(lalgotles to(bumh I where new galvanized pipe is referred to lost per hour)for each degree of cifferenoe in temperature between the pipe and the OaIJIV1N B Ftnm manufactures'specifications.Sight variations can be noted between su rranding air.The figres for iron are taken fran eperimertal data obtained at the specifications ofdfferert manufacturers,but thesefigres are represehtative. Mellon Institute.Rgresforoopperhavebe'ndalatedwithreferehoetothosefo riron on the basis of the lan)wn ratio of heat emission between the two materials. OQ.LaV1N C Rom manufacturers'specifications with the same considerations as rioted CCLLJMN I:This velum shows the number of gallons(litres)of water which will flan for Ccumn B 0.1LJiV1N D.From rranu6actues'specifications through 100 fed(30.48 metres)d the given tube and pipe with a pressure loss of 10 pounds per square inch(70 Idlopascals). Rani is based on diameters in Cblum B Ca.LJIVIN E Chic contends of 10 linear feet ao5 linear rretres of tube and have been according to Rnfessor DmGcrfs fomnlae for NBN galvanized iron pipe and NEW calalatedfromdrrti#ersgveninWurmB,bythefamalafortheoartehtsofacylinder. copper tube.Due to the corrosion ofircn and its tenderxyto accumulate sedirrentsand OCLlJiV1N F.This odium has been calculated from Cblum Eand shows the number d other foreign rretter,Rof.Dawson suggests that 15%be deduced from the figures for BU(1410 ouies)required to heat the water content crly of 10 feet(3.05 rrrdres)of the iron pipe in ceder to arrive at a reasonable performance e)Warrcy for such pipe in given tube and pipe 100°F(38°C).It requires 833.6 BTL.Is(879.5 kJ)to heat 1 gallon sevioe.wee copper resists rust and is inherently more smoeth,Rrfesscr Dluvson (a975 of water 100°F(38°(a suagge is a deduction of any 5%from the figures given for copper tube. O171JIV1N G Time figures are cal alated from Cd u7n D and show the number d Bill; (M)required to raise the temperature of 10 fed(3.05 metres)of empty tube and pipe 100°F(38°C}We to difference in the specific head of the materials,it requires 9.4 BiLJs (9.9 kJ)to raise 1 pound(0.4541alogams)of copper 100°F(38°C)and 11.0 BTUs(11.6 M)toraise 1 pared(0.45414logarrs)of iron 100'F(38°Ca. U.S.aastcmery nits i n this document are the standard;the metric urits are prai died for reference only.The\dues stated in each system are not exact equ\d erds. NIBMINC WCFiDFEADQ14Rf9s• 1516MICDLB3LWST.• B104Wr,IN46516-1740. 1154• RA 1.80D.234.0227 TEH SBRuto9;Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERAC R-t+1.5/4.295.3221• FAX+1.574295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • B(PANSION AND CONTRACTION In the nAorityof low-pressure heating systems employing copper tube and installed in smell houses or private dwellings,provision for expansion and oat ract ionisrelativelysi0e.Mai ns,risers,and io, branches to radiators should be free or fl oati ng at one end of the 0.35 I i ne.Hel es shoul d be large enough to pemit free muvernent of the tube,and care shoul d be exercised so that pi pe harx ers and 17 �? supports pemit unrestricted movem>unt and do not anchor the tube. Wrought copper tube hangers that are both practicable and neat in G5 S 151M appearance are avai I abl e. Unusual I long runs of copper tubing should be provided with an expansi on bend or l cop.By bendi ng soft temper copper tube,a o ass -in-Deform of expansion loop can be made.With the addition of Pw combination flared-tube to solderjoi nt fittings,as illustrated in Figure 1 I w 1 � r�.1 inn a1a z•i ' aac, ,these types of cops can be used hen space or other 1.a�• 0111A W:et fffiA fALM J,x,,) OUA n7g7j limitationseA st.Theoorrect proportionsofsuch expansion loopto 25 75 425 17, m m m meet van ous condi t i ons are shown in the accompanying table. �1m in• 017 7`111 (10 Z n n• Ro• TEMPERATURE. F f CS _ The above chart i s cal cul aced usi ng 1 Oft(3.05m)of copper tubi ng as R GUF E 1 the reference pant.You may use it as follows: 100ft(30.5m)of P copper tube,with a 200°F(93.3°C)temperature charge.Werence f+ poi .2256 inches for 10ft, 5.73m-nfor3.05m,multi 10 for f f po ( ) pY by a.U Bend i /+/� P i 1 00f(30.5m),resulti ng i n an answer of 2.256 i rxhes(57.3mm)of expansion or oontract ion. NOTE CSI cull at i ons for expand on and oontract i on shoul d be based on the average coefficient of e)pansion of copper which is i 0.0000094 per'F(0.00001692 per'Q between 77°Fand 212'F (25°Cand 100°C).Fbrexarroe,the expansi on for each 1Oft(3.05m) b.C:oi I ed Loop of any site of tube hued from room temperature of 70°F(21.1°q to 170 F(76.Tq,that is, 100 F(55.6 q rise,is: Rse Coefficient 100'F 1 Oft 12 inches 0.000094 0.1128 i n. c.Offset and ^ (55.6'C) x (3.05m) x (100a m) x (0.00001692) (2.87rrm) Return PAD]I OF COI LED EXPANSION LOOPS AND DBaOPED LENGTHS OF EXPANSION CFFSEFS E)Wed Bpansion Ncrrinal 1/2 1 11/2 2 21/2 3 31/2 4 Tube R L L R L R L R L R L R L R L Sim Irrh (mn) Irxh (rrm) I (mn) Ind, (mn) Ind, (mn) Ind, (mn) Irch (mn) Irxh (mn) Imh (mn) Ind, (rrm) Ind, (mr>) Ind, (mro Ind, (mn) Ind, (mn) Ind, (rrm) Ind, (mro 1/4 6 (1524) 36 KA 9 M6) 54(1371.6) 11 (194) 66(16764) 12 (.?63.8) 77(1931.8) 14 (,7'65.6) 85(2184.4) 15 (461.0) 93(13516) 16 (406.4) 102 PM) 17 (431.8) 109 8765.6) 378 7 (177.8) 44(1117.6) 10 (2.54.0) 63(16D).2) 12 (?04.8) 77(19558) 14 (-IM6) 89 PH) 16 (4064) 99 P514.6) 17 (431.8) 109 PM6) 19 (4626) 117(&11.8) 29 (5080) 126 02(10.4) 1/2 8 (g 5D(1270.0) 11 X14) 70(17780) 14 (M6) 89 pBa67 16 (4064) 99 P514.6) 18 (4572) 111 X8194) 19 (4826) 122(40988) 21 (5334) 131(43274) 22 (M8) 140(MO) 3(4 9 (2R6) 59(14986) 13 (339 83(210M 16 (4064) 101(1531.4) 19 (4826) 117 0718) 21 (5334) 131(M.4) 23 (842) 143 @5322) 25 P150) 155 POD) 26 (6814) 165(42164) 1 11 (2794) 67(1701.8) 15 (B.0) 94 123876) 18 (4672) 115 W.0) 21 (mm) 133(,13782) 24 @.) 149(3/&1.6) 26 (69a4) 163(4140.2) 25 (7112) 176(4470.4) 3D (7820) 183(47752) 11/2 13 (M4 EID P(1620) 18 W.2).113(28704 22 PB8) 136 @9054 25 P50) 160(40640) 29 (M6).179(45466) 31 (1874) 196(49784) 34 @5a6).212 P9.8) 35 (914.4)2233(57404) 2 15 (481.0) 91(1311.4) 21 (5334) 129(327667 25 (635.0) 158(40132) 29 (/466) 183(46482) 33 W 205 P7..0) 35 (914.4)224(5BB.6) 39 (M6)242(61468) 41(1011.4)259 P%6) 21/2 16 (4(r54) 102(25M) 23 (5842) 144(38576) 28 (111.2) 176(4470.4) 32 (8128)203(5156.2) 35 (314.4)227 pffi8) 40(10160)249(6324.6) 43(10WA 299 @M6) 46(11634)23B(73152) 3 18 (45-/.2) 111 X194) 25 fx0) 157 @W..8) 3D (7620) 191(4851.4) 35 (8SO)7711(5638.8) 40(10160)248(fiW 43(10922)272 0088) 47(11518)293(14422) 5D(12700)314(79756) 31/2 19 (4826) 129(3D480) 27 (618) 169(42926) 33 (q X6 M24) 38 WA 239 M6) 43(10922)2311(6781.8) 47(1193.8)293(74422) 9J(1270.0)316(t3C'26.4) 54(1371.6)338 @M4 4 29 PRO) 128(,1251.2) 29 (7366) 180(4520) 35 @SO)747(5588.0) 41 (1031.4)256(6470) 45(11430)285(7 RO) 50(1279.0)312(79238) 54(1371.6)337 @M8) 57(14478)361(5168.4) 5 23 P4.2)1142(3BD68) 32 (8128)V(51054) 39 (99D.6) 215 X3.0) 45(11430) 24(721367 51 (1M.4) 318(80772) 55(1397.0)348 @W1 6D(1224.0)376(P.4) 64(1Q56)402(102108) U.5 astorrary units in this doarne rt are the standard;the rretric units are provided for reference only The values stated in each system are not exact equivalents NIBDJ ING WCR D FEADCJ14RT9T• 1516 MI0Ml33 W Sr• BJ44gU IN 46516.4740• US4• R-t 1.800.234.0227 T67-I SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• INTB+A-flCNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboo.aom www.nibco.com AHEAD OF • CDWff Water Tubeoont i nued SELECTION . The srnooth interior of copper tube,and the design of both solder joint and flared-tube-type fittings,which have no shoulders projecting into the flow of water,decrease friction lass.With the use of copper tube,no al lowanoe is necessary for the accumulation of rust deposits in supply and service I i nes. Oonsequentl y,copper-tube I i nes are usual I y fi gured one sim seal I er than iron pipe for the same servi ce.This rule does not apply to lines from a wel Ito a pump where the non inal diameters spedfied by the pump rnanufacturer m lst be adhered to strictly. Water passing through any pipe line encounters resistance by friction.The resistance is increased by bends and turns in the line,which should be taken into account in corro ex piping systems. For example, a one-inch W elbow will cause friction loss equi vat ent to that of one foot (0.305m)of straight one-inch tube.(See below for allowance to be made for fittings and valves in equivalent lengths of tube.)Fiction loss in terns of head loss mist be taken into consideration in calculating tube sizes to be used for various types of installations. Far most average-sia-house installations with water pressures 40 M (275.&Pa)and higher, 3/4"copper-tube will be apple for main supply lines,and'/2"copper-tube can be used for risers and brandies to all fixtures.The s T-dler 3/4'tube is adequate to supply brandies, but with pressures at 40 FS (275.&Fb)and higher,water hamTer beoomtes a concern when the flaw is suddenly stopped. APPROXI MATE FRICTI ON h ALLOkNANOES FOR FITTI NGS AND `LVES I N FEET OF •` t Wrought-Copper Fitti rgs Cost Copper AI loy Fitti ngs and Valves Noninal 90° 45° Tee Tee 90° 180° 90° 45° Tee Tee Cbrrp. C3obe Cute TubeSm Bbow Bbow Rri Sdeoatlet Fend Bend Bbow Bbwv Flan SdeQatlet Stop Valve Valve (In Ir>ches) Feet (m) Feat (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) 3/8 0.5 (0.15) a5 (0.15) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 9 (275) - - - - 1/2 0.5 (0.15) 0.5 (0.15) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 1 (0.31) 1 (0.31) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 13 (397) - - - - 5(8 0.5 (0.15) 0.5 (015) 0.5 (0.15) 2 (0.61) 1 (0.31) 1 (031) 2 (0.61) 1 (031) 0.5 (0.15) 3 (0.92) 17 (5.19) - - - - 3(4 1 (0.31) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 1 (0.31) 2 (0.61) 2 (0.61) 1 (0.31) 0.5 (0.15) 3 (0.92) 21 (6.41) - - - - 1 1 (0.31) 1 (0.31) 0.5 (0.15) 3 (M) 2 (0.61) 2 ((161) 4 (1.71) 2 (0.61) 0.5 (0.15) 5 (1.53) 30 (9.15) - - 1 (0.31) 11/4 2 (0.61) 1 (0.31) 0.5 (0.15) 4 (1.72) 2 (0.61) 3 (0.92) 5 (1.53) 2 ((161) 1 (0.31) 7 (214) - - 53 (16.17) 1 (0.31) 11/2 2 (0.61) 2 (0.61) 1 (0.31) 5 (1.53) 2 (0.61) 4 (1.22) 8 (244) 3 (0.92) 1 (0.31) 9 (2.75) - - 66 (20.13) 2 (0.61) 2 2 (0.61) 2 (0.61) 1 (0.31) 7 (214) 3 (0.92) 8 (244) 11 (336) 5 (1.53) 2 (0.61) 12 (366) - - 90 (27.45) 2 (0.61) 21/2 2 (0.61) 3 (0.912) 2 (0.61) 9 (275) 4 (1.72) 16 (4.88) 14 (4.27) 8 (244) 2 (0.61) 16 (4.88) - - - - 2 (0.61) 3 3 (M) 4 (122) - - - - 5 (1.53) 20 (6.10) 18 (549) 11 (336) 2 (0.61) 20 (6.10) - - - - 2 (0.61) 31/2 4 (1.22) - - - - - - 7 (214) 24 (7.32) 24 (7.32) 14 (427) 2 (0.61) 31 (9.46) - - - - 2 (0.61) 4 - - - - - - - - 8 (244) 28 (854) 26 (8.54) 17 (519) 2 (0.61) 37 (11.29) - - - - 2 (0.61) 5 - - - - - - - - 10 (305) 37 (11.29) 41 (1251) 22 (671) 2 (0.61) 48 (14.64) - - - - - - 6 - - - - - - - - 13 (3.97) 47 (14.34) 52 (1586) 28 (8.54) 2 (0.61) 61 (11161) - - - - - - Notes:This table is based on tests conducted at Harvard University(19481 If the type of fitting is not laiwm-i.e.,whether wroL#t copper or cast at ley-use cast copper at l oy values for design. U.S.a.s#crray twits in this doaarrent are the standard;the metric units are prW ded for reference only lie values stated i n each system are not ead equ\d ents. ® NIB0DINC WCRDFEADCLARf9s• 1516MICD-B3u 'Sr- BJ04WT IN46516-1740• LISA- R-t 1.800.234.077 • TITH SERACEB Rt 1.888.446.4226• FAX 1.800.234.0557• IMffdVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • Service Temperahre*FCC) 100°F(37.8°C) 200°F(93.3-C) 300°F(148.9°G) 400°F(204.4°G) Nominal S=6000psi(414 bars) S=4800psi(331 bars) S--4700 psi(324 bars) S--3000 psi(207 bars) Tube 5m (In Indies) Type K Type L Type M Type K Type L Type M Type K I Type L Type K I Type L Formulas 1/4 1210(83.43) 1025(70.67) - - 850(58.61) 700(4827) - - 830(57.23) 690(47.58) 530(3654) 450(31.03) FD 318 1275(87.91) 890(61.37) 625(43.09) 930(64.12) 630(43.44) 460(31.72) 910(6274) 610(4206) 590(40.68) 400(27.58) tm= 2S+0.8P +C 1/2 1005(69.29) 810(55.85) 560(3861) 730(50.33) 580(39.9@) 415(28.61) 720(49.64) 570(x.30) 46D(31.72) 370(25.51) 5/8 830(57.23) 705(4861) - - 600(41.37) 500(34A8) - - 580(.19.99) 500(34.48) 380(2620) 330(2275) or 314 950(6650) 645(44.47) 450(31.06) 700(4827) 470(3241) 325(2241) 690(47.59) 460(31.72) 440(30.34) 300(20.68) _ 2 S tm when Cis O 1 72.5(49.99) 550(37.92) 380(26.20) 540(3723) 400(27.59) 270(1862) 53D(36.54) 400(17.58) 340(23.44) 260(17.93) P D-0.8tm 11/4 590(40.69) 495(34.13) 375(258s) 440(30.34) 370(2551) 270(1862) 430(29.66) 360(24.82) 280(19.31) 230(15.86) 11/2 550(37.92) 455(31.37) 370(651) 410 P2n 340(2a44) 270(1862) 400(Z7.58) 330(2275) 260(17.93) 220(15.17) tm MirimmtLbewallthidT ss 2 485(33.44) 405(27.92) 335(2310) 350(24.13) 310 P1.37) 240(16.56) 345(23,79) 305 P1.03) 23D(15.86) 190(1310) P m-ratedirtergl 21/2 450(31.03) 375(25.86) 305(21.03) 330(2275) 275(1896) 710(1517) 320(12.06) 270(1862) 210(14.48) 180(1241) wcri4r>9pressure, D atsiciedarrnterdkbe 3 430(29.65) 355(24.48) 280(19.31) 327(1206) 260(17.93) 205(14.13) 315(11.71) 255(17.58) 210(14.48) 170(11.72) S PJlwaable stress inrreterial 31/2 410(2827) 340(?;i.44) 280(19.31) 300(20.69) 250(17.24) 200(1379) 300(20.69) 245(16.89) 190(1310) 160(11.03) duetointardprommat 4 400(27.58) 325(22.41) 280(1931). 295(20.34) 240(1656) 200(1379) 290(20.00) 235(16.20) 190(1310) 150(1034) `�ingtarpaatue 5 385(265 300(10.69) 260(17.93) 290(10.00) 220(1517) 190(1310) 28D(19.31) 215(14.82) 18D(1241) 140 (9.65) o strargt�ha�ao mmedhanrd 6 385(26.56) 280(19.31) 240(16.55) 280(19.31) 2o5(14.13) 180(1241) 29D(19.31) 200(13.79) 190(1310)1 130 (8.96) 8 410(2827) 300(20.68) 255(17.58) 300(20.68) 229(1517) 190(1310) 300(10.69) 215(14.82) 200(13.79) 140 (9.66) 10 410(28.27) 3D0(20.68) 255(17.58) 310(21.37) 225(15.51) 190(1310) 305(11.03) 220(15.17) 200(1379) 150(10.34) 12 410(28.27) 280(19.31) 715(15.51) 310(21.37) 210(14.48) 190(13.10) 305 p1.03) 205(14.13) 200(13.79) 140 (9.65) "Rued irternal pressures for Cbpper Water Tube based on the strength of the tube alone and c-Wicabletosystems using suitable mechanicaljci ts. The\dues are based on the fomnia in the American Sta clard tbde, Rhva Riling AN5/AWEB31.1 1992. U.S customary units in this doarnenk are the sta mlard;the metric units are provi ded for reference cnly.the values stated in each system are rut Barad equivalents. NIBOJ INC WCRD FEADCLART9T• 1516 MIOM83J'2t'ST• 13Mq 1;IN 465164740• US4• R-t 1.800.234.0227 TB I SERACTS RH 1.888.446.4226- FAX 1.800.234.0557• INIB3VAl1CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.rtboo.00m www.nibco.com AHEAD OF • •N• C E-WATER FLOVV AND FRICTICN •► PER 100 FEET MaAffmoQ = 0.37Wirches(9.550rrm) NorrinalQD. = 0.3750imhes(9.525rrm) MirimmQD = 0.3740imh%(9.499rrm) Norrird I.D. = 0.3050indres(7.747rrm) NorrirralValI-Nclzless = 0.0350ir&m(0.089rrm) Ram Area = 0.07319q.ir&,es(47.14sq.rrm) HamnWilliarrsFbrmda CFactor = 150 RDN,Q Resare Loss Head Loss malocity RD/V,Q Ressure Loss FOCI Loss \Ajocity (CAM) 0/100ft) (ft/100ft) (ft./sec.) (cu.an'sec) 04:ai100m) (m100m) (rry-) 0.50 3.77 8.81 220 32 0.85 8.81 0.67 1.00 13.62 31.77 4.39 63 3.08 31.77 1.34 1.50 2886 67.27 6.59 95 6.53 67.27 201 200 49.17 114.54 878 126 11.12 114.54 268 250 74.33 173.08 10.98 158 16.81 173.08 3.35 3.00 104.18 242.51 13.17 189 23.57 24251 4.02 3.50 138.60 322.54 15.37 221 31.35 32254 4.68 4.00 177.49 41292 17.57 252 40.15 41292 5.35 4.50 220.75 513.46 19.76 284 49.94 513.46 802 5.00 1 268.32 1 623.96 1 21.96 1 315 1 60.70 1 623.96 6.65 1/4"TYPE L" COPPER TUBE WATER FLCYVV AND FRI CTI ON LOSS PER 100 FEET Madnunoa = 0.3760irxttes(9.550rrm) NoniredQD. = 0.3750imh%(9.525mn) MirimmQQ = 0.3740indies(9.499rrm) Norrird I.D. = 0.3150indies(8.0D1 nm) WMrd Wall Thiclv>ess = 0.0300indres(0.076mn) Row Area = 0.0779sq.indies(50.28sq.rrm) Hazen WiIIiarrsFomula CFador = 150 FLAN,Q %ssre Loss Head Loss \kiocity FlDN,Q %ssure Loss Hid Lacs wocity (am) (psi/100ft) (ft/100ft) (ft./sec.) (cu.arfsec.) "100m) (rr100m) (cosec) 0.50 3.22 7.53 206 32 0.73 7.53 0.63 1.00 11.64 27.16 4.12 63 263 27.16 1.25 1.50 24.67 57.50 6.18 95 5.58 57.50 1.88 200 4202 97.90 823 126 9.51 97.90 251 250 63.53 147.94 10.29 158 14.37 147.94 3.14 3A0 89.05 20728 1235 189 20.14 207.28 3.76 3.50 11847 275.69 14.41 221 26.80 275.69 4.39 4.00 151.71 35294 16.47 252 34.32 35294 5.02 4.50 18868 438.87 18.53 284 4268 438.87 5.65 5.00 1 229.34 1 533.32 1 20.58 1 315 1 51.88 1 533.32 1 6.27 ' OOP PER • ON •► 11 FEET MadunOD. = 0.5010indies(12.725mn) NorrinalQD. = 0.5000imhes(12.700rrm) MirimmQD = 0.4990indies(12.674rrm) Narinall.D. = 0.4020imhes(10.210rrm) Nmird Wall l idTess = 0.0490imhes(1.244mn) Row Area = 0.1269sq.indm(81.89sq.rrm) HamnWilliarrsFcnTuIa CFactor = 150 R ON,Q Ressure Loss Fwd Loss malocity RDN,Q Ressure Loss Haad Loss \Ajocity (CAM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.arVsec) 04W100m) (m100m) (rd-) 1.00 3.55 8.29 253 63 0.80 8.29 0.77 1.50 7.53 17.55 3.79 95 1.70 17.55 1.16 200 1283 29.89 5.06 126 29D 29.89 1.54 250 19.39 45.16 832 158 4.39 45.16 1.93 3AD 27.18 63.28 7.58 189 6.15 63.28 231 3.50 36.16 84.16 885 221 8.18 84.16 270 4.00 46.31 107.74 10.11 252 10.48 107.74 3.06 4.50 57.60 133.97 11.37 284 13.03 133.97 3.47 5.00 70.01 16280 1264 315 15.84 16280 3.85 550 83.52 194.19 13.90 347 1889 194.19 4.24 800 91113 228.11 15.17 379 2220 228.11 4.62 850 113.81 264.51 16.43 410 25.74 264.51 5.01 7.00 130.55 303.38 17.69 442 29.53 303.38 5.39 7.50 14834 344.68 18.98 473 33.56 344.68 5.78 800 167.18 388.40 20.71 505 37.82 388.40 E16 850 187.04 434.49 21.49 536 4231 434.49 6.55 9.00 207.93 48296 2275 568 47.03 48296 893 9.50 229.83 533.76 24.01 569 51.99 533.76 7.32 10.00 25273 1 586.89 1 25.28 1 631 1 57.17 1 586.89 1 7.70 U.S.aastcrrary units i n t s dlmn e t are the standard;the metri c units are provi ded for reference oriy.The\rJ ues stated i n each system are not exact equA ents. NIBMlNCWCRDFEADCLARTBS• 1516MICD_B3LWST.• BJ04WT,IN46516-1740• LISA- R41.80D.234.0227 • TITH SEv1C1B Rt 1.888.446.4226• FrAX 1.800.234.0557• INTB:?VA-nCNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • • •••'Y TUBE-WATER FLOW ON • 11 FEET MadnunQD. = 0.5010indm(12725mn) NorrinalQD. = 0.5000in:hes(12700nTn) MirirnmQD. = 0.4990imhes(12675mn) Narind I.D. = 0.4500imhes(10.211 rrm) Norrind Wall lhidviem = 0.0350 inches(0.889 mn) Raw Area = 0.1590 sq.indres(10261 sq.mn) Ham Wiliam Formla CFbdor = 150 FLAN,Q Ressure Loss I-fyad Loss Mdodty RDN,Q Res Loss Hx d Loss \Mocity (MA) (psi/100ft) (ft/100ft) (ftJsea) (cu.crrr'sea) (1pd100m) (0100m) (cosec) 1.00 256 5.97 221 63 0.58 5.97 0.67 1.50 5.43 1265 3.31 95 1.23 1265 1.01 200 9.24 21.54 4.42 126 209 21.54 1.35 250 13.98 3254 5.52 158 3.16 3254 1.68 3.00 19.59 45.60 6.63 189 4.43 45.60 202 3.50 26.06 60.65 7.73 221 5.90 60.65 2.36 4.00 33.37 77.64 8.84 252 7.55 77.64 2.69 4.50 41.51 96.54 9.94 284 9.39 96.54 3.03 500 50.45 117.32 11.05 315 11.41 117.32 3.37 5.50 60.19 139.94 1215 347 13.62 139.94 3.70 6.00 70.72 164.38 13.26 379 16.00 164.36 4.04 6.50 8201 190.62 14.36 410 18.55 190.62 4.36 7.00 94.08 218.63 15.46 442 21.28 218.63 4.71 7.50 106.90 248.40 16.57 473 24.18 248.40 5.05 8.00 120.48 279.90 17.67 505 27.25 279.90 5.39 8.50 134.79 313.12 18.78 536 30.49 313.12 5.72 9.00 149.84 348.04 19.88 568 33.90 348.04 6.06 9.50 165.62 384.65 20.99 599 37.47 384.65 6.40 10.00 1 18213 1 42294 1 2209 1 631 1 41.20 42294 6.73 ' COPPER C E-WATER FLOW AND FRI CTI ON A 11 ME MamrrumQD. = 0.5010indhes(12.725rrm) NorrinalQD. = 0.5000imhes(12700rrrn) MininumQD. = 0.4990indhes(12675mn) Norrird I.D. = 0.4020indhes(10.211 rrrn) Nom rd Wall 1hidme% = 0.0250 inches(0.635 mn) RoN Area = 0.1269 sq.ind>es(81.89 sq.rrm) Hawn William Famla CFador = 150 FLAN,Q R)awe Loss HLad Loss Mdocity FLAN,Q Ressure Loss Hand Loss \Modty (MM) (psi/100ft) (ft/lo0ft) (ft./sec) (cu.ar✓sea) OdDa/100m) (0100m) (cosec) 1.00 205 4.79 202 63 0.46 4.79 0.61 1.50 4.35 10.14 3.03 95 0.98 10.14 0.92 200 7.41 1726 4.03 126 1.66 17.26 1.23 250 11.20 26.09 5.04 158 253 2&09 1.54 3.00 15.70 35.55 6.05 189 3.55 36.55 1.84 3.50 20.89 48.61 7.06 221 4.73 48.61 215 4.00 26.75 6223 8.07 252 6.05 6223 246 4.50 33.27 77.39 9.08 284 7.53 77.39 2.77 5.00 40.44 94.04 10.09 315 9.15 94.04 3.07 5.50 48.25 11217 11.09 347 10.91 11217 3.38 6.00 56.66 131.76 1210 379 12.82 131.76 3.69 6.50 65.74 15279 13.11 410 14.87 15279 4.00 7.00 75.41 175.25 14.12 442 17.06 17525 4.30 7.50 85.69 199.10 15.13 473 19.38 199.10 4.61 8.00 96.57 224.35 16.14 505 21.84 224.35 4.92 8.50 106.04 250.98 17.15 536 24.44 250.98 5.23 9.00 120.11 278.97 18.16 568 27.17 278.97 5.53 9.50 13276 308.32 19.16 599 30.03 301132 5.84 10.00 1 145.99 1 339.01 1 20.17 631 33.C2 339.01 6.15 U.S a csto»ary units in this doaxnent are the standard;the mstdc arts are provided fo- refererioe only The values stated in earl system are riot exact ecp\rJents. NIBOJINCWCRDFEADCLART9T• 1516MIOM83J i'ST• BJ44gUIN465164740• LJS4• R-t1.800.234.0227 TT37-I SBRACES RH 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.rlboo.00m www.nibco.com AHEAD OF • TYPE" •••• C E-WATER FLOVV AND FRICTICN •► PER 100 FEET Mwdnmc)n = 0.625indies(15.900rrm) NarirelQQ = 0.6250imhes(15.875rrm) MirimmQCt = 0.624imh%(15.850rrm) Norrird I.D. = 0.527in&.es(13.3858rrm) m No nal Wal I-h cl zle% = 0.049 it ches(1.245 rrm) Ram Area = 0.2181 sq.ir&es(140.73 sq.rrm) H�mnV\AIIiarrsFcmula CFador = 150 RDN,Q Resare Loss Head Loss malodty RD/V,Q Ressure Loss Fbed Loss \Ajodty (CAM) (psi/10m) (ft/100ft) (ft./sec.) (cu.an'sec) (14:bv100m) (m100m) (m'sea) 1.00 0.95 222 1.47 63 0.22 222 0.45 1.50 202 4.70 221 95 0.46 4.70 0.67 200 3.44 8.00 294 126 0.78 8.00 0.90 250 5.19 1210 3.68 158 1.18 1210 1.12 3.00 7.28 16.95 4.41 189 1.65 16.95 1.34 3.50 9.69 2254 5.15 221 219 2254 1.57 4.00 1240 2&86 5.88 252 281 28.86 1.79 4.50 15.43 35.88 6.62 284 3.49 35.813 202 5.00 18.75 43.61 7.35 315 4.24 4361 224 5.50 2237 5201 8109 347 506 5201 247 6.00 2628 61.10 8.83 379 5.95 61.10 269 6.50 30.48 70.85 9.56 410 6.90 70.85 291 7.00 34.97 81.26 10.30 442 7.91 81.25 314 7.50 39.73 9232 11.03 473 8.99 9232 3.36 &00 44.78 104.03 11.77 505 10.13 104.03 3.59 8,50 50.10 116.38 12.50 536 11.33 116.38 381 9.00 55.69 129.36 13.24 563 1260 129.36 4.03 9.50 61.56 14297 13.97 599 1393 14297 4.26 10.00 67.69 157.20 14.71 631 15.31 157.20 4.48 10.50 74.10 17205 15.44 662 16.76 17205 4.71 11.00 80.76 187.51 16.18 694 1&27 187.51 4.93 11.50 87.69 203.58 16.91 725 19.84 203.58 5.16 12.00 94.88 220.26 17.65 757 21.46 220.26 5.38 12.50 10234 237,54 1&39 789 23.15 237.54 5.60 13.00 110.05 255.41 19.12 820 24.89 255.41 5.83 13.50 118.01 273.89 19.86 852 26.70 273.89 6.05 14.00 126.23 29295 20.59 883 21156 29295 6.28 COPPER" C E-WATER FLOVV AND •N LOSS PER 100 FEET MadmmQD. = 0.625indies(15.900rrm) N rrird QQ = 0.6250imhes(15.875rrm) MirrmmQQ = 0.624ir&es(15.850rrm) Narirtri I.D. = 0.5450ir&es(13.843rrm) Ncrdrd Wall ThidTess = 0.049indies(1.245rrm) RavArea = 0.2333sgAr&es(150.50sq.rrm) FfsmnV\AIliarrsFormala CFador = 150 FLON,Q Resare Loss FLad Loss \Idodty RDN,Q Resare Loss F13erl Loss Mblodty ((TM) (pd/100ft) (ft/10M) (ft./sec.) (cu.an'seC) Kar100m) (m100m) (rry-) 1.00 0.81 1.89 1.38 63 0.18 1.89 0.42 1.50 1.71 3.99 206 95 0.39 3.99 0.63 200 292 6.80 275 126 0.66 6.80 0.84 250 4.41 10.27 344 158 1.00 10.27 1.05 300 6.18 14.39 4.13 189 1.40 14.39 1.26 350 &23 19.14 4.81 221 1.86 19.14 1.47 4.00 10.53 24.51 5.50 252 238 24.51 1.68 4.50 13.10 30.47 6.19 284 296 30.47 1.89 5.00 15.92 37.03 6.88 315 3.60 37.03 210 5.50 19.00 44.17 7.56 347 4.30 44.17 231 6.00 2202 51.89 8.25 379 5.05 51.89 252 &50 25.89 60.17 8,94 410 5.86 60.17 272 7.00 29.70 69.01 9.63 442 6.72 69.01 293 7.50 33.74 7&41 10.31 473 7.63 78.41 3.14 &00 38.03 88.35 11.00 505 8.60 8&35 335 &50 4255 98,83 11.69 536 9.62 91183 3.56 9.00 47.30 109.86 1238 569 10.70 109.86 377 9.50 5228 121.41 13.07 599 11.83 121.41 3.98 10.00 57.49 133.50 13.75 631 130) 133.50 4.19 10.50 6292 146.11 14.44 662 14.23 146.11 4.40 11.00 68.59 159.24 15.13 694 15.51 159.24 4.61 11.50 74.47 172.89 15.82 725 16.85 17289 4.82 12.00 80.58 187.05 16.50 757 1823 187.05 5.03 12.50 86.91 201.73 17.19 789 19.66 201.73 5.24 13.00 98.46 216.91 17.88 820 21.14 216.91 E45 13.50 100.22 23260 18.57 852 2267 23260 5.66 14.00 107.20 1 248.78 1 19.25 1 883 1 24.25 1 248.78 1 5.87 U.S.a stcrrmy units in this down-at are the standard;the ma dc units are pravi ded for reference only.The values stated in each system are not exact eq ival en ts. •1 NIBMlNCWCRDFEADQIARTBS• 1516MICOLB3LWSL• BJ04WT,IN46516-1740• LISA- 1341.800.234.0227 TITH SEv1C1B Rt 1.888.446.4226• FAX 1.800.234.0557• INTB:?VA-nCNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 1/2"TYPE"M" COPPER TUBE-WATER FLOW AND FRICTION LOSS PER 100 FEET MadnunQD. = 0.626indies(15.900rrm) NorrinalQD. = 0.6250imhes(15.875rrm) MirdmrnQD. = 0.624imhes(15.850rrrn) Norrind l.D. = 0.5690imhes(14.4526mn) Nominal Wail l idvie% = 0.028 inches(0.711 rrrn) Raw Area = 0.2543 sq.inches(164.05 sq.rrm) HamWilliarrsFamla CRdor = 150 FLAN,Q Ressure Loss I-fyad Loss Mblodty FLAN,Q Ressure Loss Fkad Lass Mblocity (am) (psi/100ft) (ft/100ft) (ftJsea) (cu.an'sea) 04>ai100m) (m100m) (rry ) 1.00 0.66 1.53 1.25 63 0.15 1.53 0.38 1.50 1.39 3.24 1.89 95 0.31 3.24 0.58 20D 237 5.51 252 125 0.54 5.51 0.77 250 3.59 8.33 3.15 158 0.81 8.33 0.96 3.00 5.01 11.67 3.79 189 1.13 11.67 1.15 3.50 6.67 15.52 4.42 221 1.51 15.52 1.35 4.00 854 19.87 5.05 252 1.93 19.87 1.54 4.50 10.62 24.71 5.613 284 240 24.71 1.73 5.00 1291 30.03 6.31 315 292 30.03 1.92 5.50 15.41 35.82 6.94 347 3.48 35.82 2.12 6.OD 1810 4207 7.57 379 4.09 4207 231 6.50 20.99 48.79 8.20 410 4.75 4879 250 7.00 24.08 55.96 8.83 442 5.45 55.96 269 7.50 27.36 63.57 9.46 473 819 63.57 288 8.00 3033 71.64 10.09 505 6.96 71.64 3.OB 8.50 34.50 80.14 10.72 536 7.80 80.14 3.27 9.00 3835 89.08 11.36 568 866 89.08 3.46 9.50 4239 98.45 11.99 599 9.59 9845 3.65 10.00 4861 10825 1262 631 10.54 108.25 3.85 10.50 51.02 11847 13.25 662 11.54 11847 4.04 11.00 55.61 129.12 13.88 694 12.58 129.12 4.23 11.50 60.39 140.19 14.51 725 13.66 140.19 4.42 1200 65.34 151.67 15.14 757 14.78 151.67 4.61 1250 70.47 163.57 15.77 789 15.94 163.57 4.81 13.00 75.78 175.88 16.40 820 17.14 175.88 5.00 13.50 81.26 18860 17.03 852 18.38 18860 519 14.00 86.93 201.72 1 17.66 1 883 1 19.66 201.72 1 5.36 i COPPER" :E-WATER FLOW AND ON •• 11 FEET Ma)amrnQD. = 0.751 indhes(19.075rrm) Norrird OD. = 0.7500indhes(19.050rrm) MinimsnQD. = 0.749indhes(19.025rrrn) Nondrd I.D. = 0.6520imhes(16.5608rrm) Nonind Wall Thidmem = 0.049 inches(1.245 rrrn) Flaw Area = 0.3339 sq.inches(215.40 sq.rrrn) HFmnWlliarrsFan,da CFador = 150 FLAN,Q Ressure Loss Haad Loss \klodty FLON,Q Ressu a Lass HaE d Loss Mblocty (Caul) (ps/1OOft) (ft/100ft) (ftJsm) (cu.an'sea) (Iar100m) (m100m) (rry-) 1.OD 0.34 0.79 0.96 63 0.08 0.79 0.29 200 1.22 284 1.92 126 0.28 284 0.59 3.00 253 6.02 288 189 058 6.02 0.88 4.00 4.40 10.24 3.84 252 1.00 10.24 1.17 5.00 6.66 15.48 4.80 315 1.51 15.48 1.46 6.00 9.33 21.69 5.77 379 211 21.69 1.76 TOD 1241 28.85 6.73 442 281 28.85 205 8.00 15.90 36.93 7.69 505 3.60 36.93 234 9.OD 19.77 45.92 8.65 568 4.47 45.92 2.64 10.00 24.03 55.81 9.61 631 544 55.81 293 11.00 28.67 66.57 10.57 694 6.49 66.57 3.22 1200 33.69 78.20 11.53 757 7.62 78.20 3.51 13.00 39.07 90.68 1249 820 884 90.68 3.81 14.00 44.82 104.00 13.45 883 10.14 104.00 4.10 15.00 50.92 11816 14.41 946 11.52 11816 4.39 16.00 57.39 133.14 15.37 1009 12.98 133.14 4.69 17.00 64.21 14895 16.34 1072 14.52 14895 4.98 18.00 71.38 165.56 17.30 1136 16.15 165.56 5.27 19.00 7889 18298 1826 1199 17.85 18298 5.56 20.00 8876 201.19 19.22 1262 19.63 201.19 5.86 21.00 94.96 220.19 20.18 1325 21.48 220.19 6.15 2200 1 1013.51 1 239.98 1 21.14 1 1388 1 23.41 239.98 1 6.44 U.S ass way grits in this dmrr ent are the standard;the n-&uinits are presided for refere only.The\duesstated in each systemare riot exadegLivalertts. Nll3MlNCWQaDHI5DCL14RIES• 1516MIDDL83JWST• l3J44gUIN46516-4740• LISA- R-t1.800.234.0227 m TECH SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• IN193VAl1QVALSERACE R-t+1.574.295.3221• FAX-+1.574295.3455 • www.riiboo.00m www.nibco.com AHEAD OF • TYPE" COPPER" C ' • AND •N LOSS PER 100 FEET McwffmQa = 0.751 inches(19.075 ran) NarinalaQ = 0.7500indaes(19.050rrm) MirimmQD. = 0.749imhes(19.025rrm) Narirall.D. = 0.6680irdies(16.9164rrm) Narir�al VVJ I-h cl zle% = 0.042 ir&es(1.067 rrm) Rav Area = 0.3484 sq.ir&es(224.75 sq.rrm) HamnV\AIIiarrsFcmUla CFador = 150 RD/V,Q Ressure Loss H3ad Loss malocity RD/V,Q Ressure Loss FOCI Loss Mdocity (C-M) (psi/1ooft) (ft/1ooft) (ft./sec.) (cu.an'sec) 04:bv100m) (m1oom) (m'sea) 1.00 0.30 0.71 0.92 63 0.07 0.71 0.28 200 1.10 2.56 1.84 126 0.25 256 0.56 3.00 233 5.43 276 189 0.53 5.43 0.84 4.00 3.97 9.24 3.68 252 0.90 9.24 1.12 5.00 6.00 13.96 4.60 315 1.36 13:96 1.40 600 8.41 19.56 5.53 379 1.90 19.56 1.68 7.00 11.20 2602 6.45 442 253 2602 1.96 8.00 14.34 33.31 7.37 505 3.24 33.31 225 9.00 17.83 41.41 8.29 568 4.03 41.41 253 10.00 21.67 50.33 9.21 631 4.90 50.33 281 11.00 25.86 60.03 10.13 694 5.85 60.03 3.09 12.00 30.38 70.51 11.05 757 6.87 70.52 3.37 13.00 35.23 81.77 11.97 820 7.97 81.77 3.65 14.00 40.41 93.79 1289 883 9.14 93.79 3.93 15.00 45.52 105.56 13.81 946 10.39 106.56 421 16.00 51.75 120.07 14.74 1009 11.71 120.07 4.49 17.00 57.90 134.32 15.66 1072 13.10 134.32 4.77 18.00 64.37 149.30 16.58 1136 14.56 149.30 5.05 19.00 71.15 165.01 17.50 1199 16.09 165.01 5.33 20.00 78.24 181.43 18.42 1262 17.70 181.43 5.61 21.00 85.64 198.57 19.34 1325 19.37 198.57 5.89 22.00 93.34 1 216.42 1 20.26 1 1388 1 21.11 1 216.42 1 6.18 COPPER" C E-WATER FLOW AND FRICTI ON •► PER 100 FEET MadnunQa = O.s76inches(22250nm) Nomrdaa = 0.875oinches(22.225mn) Minnunoa = 0.874indres(22.200rrm) Ncnirrall.a = 0.7450inches(18.923rrm) NcmrsdVVaIIThidTess = 0.065imhes(1.651rrm) Raw Area = 0.4359s4ir&es(281.24sq.rrm) HazenV\AlliarrsFbmula CFador = 150 RDN,Q Ressure Loss Head Loss \kiaity FLAN,Q Ressure Loss Head Lass laity (CAM) (psi/1ooft) (ft/1ooft) (ft./sec.) (cu.arYsec.) "loom) (m'1ODm) (ms) 2.00 0.64 1.49 1.47 126 0.14 1.49 0.45 4.00 230 5.35 294 252 0.52 5.35 0.90 6.00 4.86 11.34 4.42 379 1.10 11.34 1.35 800 8.31 19.30 5.89 505 1.88 19.30 1.79 10.00 1256 29.17 7.36 631 2.84 29.17 224 12.00 17.61 40.87 8.83 757 3.98 40.87 269 14.00 23.42 54.36 10.30 883 5.30 54.36 3.14 16.00 30.00 69.59 11.78 1009 6.79 69.59 3.59 18.00 37.31 86.54 13.25 1136 8.44 86.54 4.04 20.00 45.35 105.16 14.72 1262 10.26 105.16 4.49 22.00 54.10 125.44 16.19 1388 1224 125.44 4.94 24.00 63.56 147.34 17.66 1514 14.38 147.34 5.38 26.00 73.72 170.86 19.14 1640 16.68 170.86 5.83 28.00 84.56 195.97 20.61 1766 19.13 195.97 6.28 MOD 1 96.09 1 22265 1 22.08 1893 1 21.74 1 22265 1 6.73 U.S.a stcrrary r nits in this document are the standard;the metric units are provided for reference oily.The\rJ ues stated in each system are ncl exact equ\d tints. ® NIBMINCVVCRDFEADCLARTBS• 1516MICD_B3LWST.• BJ04WT,IN46516-1740• LISA- R41.800.234.0227 • TEH SERACTB Rt 1.888.446.4226• FrAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • ' 00"7'TUBE-WATER FLOW ON • 11 FEET McDdnmQD. = 0.876indies(22250rrm) NorrirelQD = 0.87Wimhes(22.225mn) MirinunQD. = 0.874indies(M200mn) Norrirell.D. = 0.7850imhes(19.939mn) Nominal Wall Thidvhecs = 0.045 inches(1.143 mn) Raw Area = 0.4840 sq.inches(31225 sq.mn) HamnWlliansFomula CFador = 150 FLAN,Q Ressure Lass Ffrad Loss Mdodty FLAN,Q Ressure Loss Fioad Lass Mdocity (am) (psi/100ft) (ft/100ft) (ftJsec) (cu.arYsea) 04ai100m) (m10om) (cosec) 2.00 0.4944 1.1517 1.3258 125.17 0.1118 1.1517 0.4041 4.00 1.7846 4.1519 26516 25235 0.4037 4.1519 0.8082 6.00 3.7815 8.7905 3.9774 378.52 0.8554 8.7905 1.2123 8.00 6.4425 14.9675 5.3032 504.69 1.4573 14.9675 1.6164 10.00 9.7393 226169 6.6290 630.87 22031 226169 20205 1200 13.6513 31.6896 7.9548 757.04 3.0880 31.6896 24246 14.00 18.1618 421472 9.2806 883.21 4.1083 421472 28287 16.00 23.2573 53.9578 10.6064 1009.39 5.2610 53.9578 3.2328 18.00 28.9264 67.0944 11.9322 1135.56 6.5434 67.0944 3.6369 20.00 35.1590 81.5338 13.2580 1261.73 7.9532 81.5338 4.0411 2200 41.9465 97.2555 14.5838 1387.91 9.4885 97.2555 4.4452 24.00 49.2811 114.2412 15.9096 1514.08 11.1477 1 114.2412 4.8493 25.00 57.1557 1324747 17.2354 1640.25 129290 1324747 5.2534 28.00 65.5641 151.9408 18.5613 176643 14.8311 151.9408 5.6575 30.00 1 74.5002 1 1726261 1 19.8871 1 189260 16.8525 1726261 6.0616 3/4"TYPE"M 00PPER TUBE-WATER FLOW AND M CTI ON LOSS PER 100 FEET Mab rrum OD. = 0.876 indhes(22250 rrm) Nomnal QD. = 0.8750 im hes(22225 rrrn) MininumOD. = 0.874indhes(22200mn) Nonird l.D. = 0.8110ind-m(2D.5994mn) NoninalWad IThidvhem = 0.032inches(0.813con) flaw Area = 0.5156sq.ind-es(333.27sq.con) Hawn W lliarrs lim ula CFador = 150 FLON,,Q Ressure Loss Fad Loss Mdodty FLAN,Q Ressre Loss Fiaad Loss Mdocity (G-M) 0/100ft) (ft/100ft) (ftJsec.) (cu.an'sea) (14d100m) (m'100m) (m'sec) 20D 0.42 0.98 1.24 126 0.10 0.98 0.38 4.00 1.52 3.54 248 252 0.34 3.54 0.76 6.00 3.23 7.50 3.73 379 0.73 7.50 1.14 8.00 5.50 1277 4.97 505 1.24 1277 1.51 10.00 1131 19.30 6.21 631 1.88 19.30 1.89 1200 11.65 27.04 7.45 757 264 27.04 227 14.00 15.50 35.97 8.70 883 3.51 35.97 265 16.00 19.85 46.05 9.94 1009 4.49 4605 3.03 18.00 24.69 57.25 11.18 1136 5.58 57.26 3.41 20.00 30.01) 69.58 1242 1282 6.79 69.58 3.79 2200 35.80 83.00 13.66 1388 8.10 83.00 4.16 24.00 4206 97.49 14.91 1514 9.51 97.49 4.54 26.00 48.78 113.05 16.15 1640 11.03 113.05 4.92 28.00 55.95 129.66 17.39 1766 12.66 129.66 5.30 30.00 1 63.58 1 147.32 1 18.63 1 1893 1 14.38 147.32 1 5.68 U.S.a istanary units i n thi s doamert are the standard;the n-etd c units are provided fa- refera-ce only.The val ues stated i n each system are not exad equ\rciert& NIBCD INC WCRD FEADC LART9T• 1516 MIOM83J 2i'ST• BJ44gU IN 465164740• LJS4• R-t 1.800.234.0227 TBaiSERACESPH 1.888.446.4226• FAX 1.800.234.0557• INTB+AT1QVALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 • www.rhiboo.00m www.nibco.com AHEAD OF • 1"TYPE"K' COPPER TUBE-WATER FLOW AND FRI CTI ON LOSS PER 100 FEET Madffmoc. = 1.1255irches(28.613rrm) NoMMOD = 1.1250imhes(28.575rrm) MirinunQa = 1.1235imhes(28.537rrm) NorrirEd I.D. = 0.9850imhes(25.273rrm) Nomr�alVUlhclrless = 0.0650ird-es(1.651rrm) RoN Area = 0.77769q.ir&es(501.65sq.rrm) HamnV\AIIiarrsFumula CFactor = 150 RD/V,Q Resare Loss Head Loss \Ajocity RD/V,Q Ressure Loss Hid Loss Mdocity ((TM) (psi/1CIOft) (ft/1CIDft) (ft./sec.) (cu.an'sec) (14:bv100m) (m100m) (m'seo.) 250 024 0.55 1.03 158 0.05 0.55 0.31 5.00 0.85 1.98 206 315 0.19 1.98 0.63 7.50 1.80 4.19 3.09 473 0.41 4.19 0.94 10.00 3.07 7.14 4.13 631 0.70 7.14 1.26 12.50 4.65 10.78 5.16 789 1.05 10.78 1.57 15.00 6.51 15.11 6.19 946 1.47 15.11 1.89 17.50 8.66 20.10 TM 1104 1.96 20.10 220 20.00 11.09 25.73 8.25 1262 251 25.73 252 22.50 13.80 31.99 9.28 1419 3.12 31.99 283 25.00 16.77 38.88 10.32 1577 3.79 38.88 3.14 27.50 20.01 46.37 11.35 1735 4.53 46.37 3.46 30.00 23.51 54.47 12.38 1893 5.32 54.47 3.77 32.50 27.27 63.17 13.41 2050 6.17 6317 4.09 35.00 31.28 7245 14.44 2208 7.0B 7245 4.40 37.50 35.54 8231 15.47 2366 8.04 8231 4.72 40.00 40.05 9275 16.50 2523 9.06 9275 5.03 42.50 44.81 103.76 17.54 2681 10.14 103.76 5.34 45.00 49.81 115.33 18.57 2B39 11.27 115.33 5.66 47.50 55.06 127.47 19.60 2997 1246 127.47 5.97 50.00 60.55 140.15 20.63 3154 13.70 140.15 6.29 52.50 66.27 153.39 21.66 3312 14.99 153.39 6.60 55.00 1 7224 1 167.18 1 22.69 1 3470 1 16.34 1 167.18 1 6.92 •"ER TUBE-WATER FLOW AND FRICTI ON •S100FEET Maammoa = 1.1255ir&es(28.613rrm) Nmirdaa = 1.1250irxttes(28.575rrm) Mhnunoa = 1.1235irxttes(28.537rrm) Ncnirrall.a = 1.0250ind)es(26.035rrm) NorriM WA I Thidom = 0.0500 i mhes(1.270 rrm) Raw Area = 0.8252 s4 indies(532.36 sq.rrm) HazenV\Allia"Famila CFador = 150 R_ON,Q Resare Loss Head Loss \kiodty FLON,Q %ssure Loss Head Lass \Modty (am) (psi/100ft) (ft/100ft) (ft./sec.) (cu.arYsec.) "loom) (m'1ODm) (m'sea) 250 0.20 0.48 0.97 158 0.05 0.48 0.30 5.00 0.74 1.71 1.94 315 0.17 1.71 0.59 7.50 1.56 3.63 292 473 0.35 3.63 0.89 10.00 266 6.18 3.89 631 0.60 6.18 1.19 12.50 4.02 9.33 4.86 789 0.91 9.33 1.48 15.00 5.64 1308 5.83 946 1.27 1308 1.78 17.50 7.50 17.39 6.80 1104 1.70 17.39 207 20.00 9.60 2227 7.78 1262 2.17 2227 237 22.50 11.94 27.69 8.75 1419 270 27.69 267 25.00 14.52 3365 9.72 1577 3.28 3365 296 27.50 17.32 40.13 10.69 1735 3.92 40.13 3.26 30.00 20.35 47.14 11.66 1893 4.60 47.14 356 32.50 2360 54.67 1264 2050 5.34 54.67 3.85 35.00 27.07 6270 13.61 2208 6.12 6270 4.15 37.50 30.76 71.24 14.58 2366 6.96 71.24 4.44 40.00 34.66 80.27 15.55 2523 7.84 8D.27 4.74 42.50 3878 89.80 16.51 2681 8.77 89.80 SO4 45.00 43.11 99.81 17.50 2839 9.75 99.81 5.33 47.50 47.65 110.31 18.47 2997 10.78 110.31 5.63 50.00 5240 121.29 19.44 3154 11.85 121.29 E93 51.50 57.36 132.75 20.41 3312 1297 13275 6.22 56.00 6252 1 144.68 1 21.38 1 3470 1 14.14 1 144.68 1 6.52 U.S.aastorrary Lhts i n this document are the standard;the met6c units are provided for reference oily.The\rJ ues stated i n each system are not exact equ\d eats. © NIB00INCWCRDFEADCLARf9s• 1516MICD_B3LWST.• BJ04WT,IN46516-1740• LISA- R41.80D.234.0227 • TEH SERACTB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE RFt+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 1"TYPE"M" COPPER TUBE-WATER FLOW AN D FRI CTI ON LOSS PER 100 FFJ-7- MadnunQD. = 1.1265inches(211613rrm) NorrinalQD. = 1.1250imhes(2&575rrm) MinirrrmQD = 1.1235immhes(2&537rrm) Narind l.D. = 1.0558immhes(26.797rrm) Norrird wall'Thid,3.19M = 0.0350 inches(0.989 nm) FIoN area = 0.8742 sq.indres(563.98 sq.rrm) HamnWlliamlomula CRdor = 150 FLAN,Q Ressure Loss Hoard Loss Mblodty RDN,Q Ressure Loss Head Lass \Mocity (am) (psi/100 ft) (ft/100 ft) (ftJsea) (ai.an sea) 04 ai 100 m) (m 1o0 m) (co sec) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 1.36 3.15 275 473 0.31 3.15 a84 10.00 231 5.37 3.67 631 0.52 5.37 1.12 1250 3.49 all 4.59 789 0.79 all 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1252 1.89 19.35 224 2250 10.38 24.06 8.26 1419 235 24.06 252 25.00 1261 29.24 9.18 1577 285 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 3250 20.51 47.51 11.93 2050 4.64 47.51 3.64 35.00 23.52 54.49 1285 2208 5.32 54.49 3.92 37.50 26.73 61.91 13.76 2366 6.05 61.91 4.19 40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47 4250 33.70 78.04 15.60 2681 7.62 78.04 4.75 45.00 37.47 86.74 16.52 2839 &47 86.74 5.03 47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 1 8,35 3154 10.30 105.41 559 5250 49.84 115.37 19.27 3312 11.28 11537 5.87 55.00 1 54.33 1 125.74 1 20.19 1 3470 1 12.29 1 125.74 1 6.15 1 114!'TYPE"K' COPPER TUBE-WATER FLOW AN D FRI CTI ON LOSS PER 100 FEET MaprrumOD. = 1.3765indies(34.963mn) NomnalQD = 1.3750irches(34.925mn) MlninumOD. = 1.3735indies(34.887rrm) Norrinall.D. = 1.2450indies(31.623rrm) Norrird Wall Thidmess = 0.0650imhes(1.651 con) Raw Area = 1.2174sq.indres(785.41 sq.con) HamnWlliarrsFomula CFador = 150 FLO.N,Q Ress<ae Lass Head Loss \kiodty FLON,Q Ressre Lass Head Lass W ocity (CAM) (psi/1o0ft) (ft/1ooft) (ftJsec.) (ai.onsea) W4100m) (m1o0m) (cosec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 240 264 631 023 240 0.80 15.00 219 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 &65 527 1262 0.84 &65 1.61 25.00 5.64 law 6.59 1577 1.27 13.06 2.01 30.00 7.90 18.30 7.91 1893 1.79 18.30 241 35.00 10.51 24.34 9.22 2208 238 24.34 281 40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21 45.00 16.74 38.75 11.86 2839 3.79 3&75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 2427 56.18 14.49 3470 5.49 56.18 4.42 60.00 2&52 65.99 15.81 3785 6.45 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 1 76.52 5.22 70.00 37.94 87.76 1&45 4416 &58 87.76 5.62 75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02 80.00 4&58 1 11235 1 21.08 1 5047 1 10.99 11235 1 6.43 U.S a istm-ay runts i n this doa rrent are the standard;the rretd c udts are provided for reference Orly.The vd Lies stated i n each system are not exact ec}u\rderta NIBDJINC WCRD FEADCLART9T• 1516 MIOM83J'2i'Sr..• BJ44gU IN 465164740• LJS4• R-t 1.800.234.0227 TT37-I SBRACES PH 1.888.446.4226• FAX 1.800.234.0557• IN1T33Val CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 • www.riiboo.00m www.nibco.com AHEAD OF • TYPE" •••• C E-WATER FLOW AND FRICTI ON •► 100FEET MaxanunQD. = 1.3765indies(34.963rrm) NamnalQD. = 1.375inches(34.925rrm) MinirrmQD. = 1.3735irxhes(34.887rrm) Norrinall.D. = 1.265irxhes(32.131nm) NomrelWall-hclrless = 0.0550in&es(1.397rrm) Row Area = 1.25689q.indies(810.85sq.rrm) HamnWiIIiarrsFcmula CRdor = 150 R DvV,Q Rye Loss Head Loss malocity RD/V,Q Ressure Loss Flead Loss \Ajocity ((FM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.cn'sec) 04:bv100m) (m100m) (m'sea) 5.00 026 0.52 128 315 0.06 0.62 0.39 10.00 0.96 2.22 255 631 0.22 222 0.78 15.00 202 4.70 3.83 946 0.46 4.70 1.17 20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56 25.00 5.22 1209 6.38 1577 1.18 1209 1.95 30.00 7.31 16.94 7.66 1893 1.65 16.94 233 35.00 9.73 2253 8.93 2208 220 2253 272 40.00 1245 28.84 10.21 2523 282 28.84 3.11 45.00 15.49 35.86 11.49 2839 3.50 35.85 3.50 50.00 18.83 43.58 1276 3154 4.26 43.58 3.89 55.00 2246 51.98 14.04 3470 5.08 51.96 4.28 60.00 25.39 61.06 15.32 3785 5.97 61.06 4.67 65.00 30.61 70.81 16.59 4101 6.92 70.81 5.06 70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45 75.00 39.89 9227 19.15 4732 9.02 9227 5.84 80.00 1 44.96 1 103.97 1 20.42 1 5047 1 10.17 1 103.97 1 6.22 11/4"TYPE"M" CCIPPER TUBE-WATER FLOW AND FRICTI ON LOSS PER 100FEET Madnunaa = 1.3765indies(34.963mn) NoMrdQD. = 1.3750imhes(34.925mn) MirimmQD = 1.3735ir&es(34.887mn) Nonirell.D = 1.2910irdm(32.7914mn) Norri nal Wall Thidv� = 0.0420 i r&es(1.067 rrm) Row Area = 1.3090 sq.ir&es(844.52 sq.rrm) HamnWilliarrsFcrrrda CFactor = 150 RDN,Q %ss<re Loss Hgad Loss Wocity FLON,Q %ssrre Lots Head Lass \Modty (GM) (ps/100ft) (ft/100ft) (ft./sec.) (cu.crosec.) "loom) (0100m) (cosec.) 5.00 0.24 0.56 1.23 315 0.05 0.56 0.37 10.00 0.87 201 245 631 0.20 201 0.75 15.00 1.83 4.26 3.68 946 0.41 4.26 1.12 20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49 25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87 30.00 6.52 15.34 7.35 1883 1.50 15.34 224 35.00 8.81 20.40 8.59 2208 1.99 20.40 261 40.00 11.28 25.12 9.80 2523 255 26.12 299 45.00 14.03 3248 11.03 2839 3.17 3248 3.36 50.00 17.05 39.47 1225 3154 3.86 39.47 3.74 55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11 60.00 23.90 55.31 14.71 3785 5.41 55.31 4.48 65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86 70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23 75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60 80.00 1 40.72 1 94.17 1 19.61 1 5047 1 9.21 1 94.17 1 5.98 U.Sc storr aryunitsinthisdocu mentarethestan dard;therratri cunitsareprovidedfor reference only the val Lies stated i n each system are not exad equval ends. NIBMINGMIRLDFEADCLARTBS• 1516MICDLB3LWSL• B104Wf,IN46516-1740• U54• 1`1141.800.234.0227 •• TITH SBRAQEB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERAC R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 1 1/2"TYPE"K' CCPPER TUBE-WATER FLCk/V AND FRICTICIN LCISS PER 100 FEET MadnmQD. = 1.6270inches(41.326mn) Norrird0l).. = 1.6250imhes(41.275mn) MirinunQD = 1.6230imhes(41.224mn) Narird l.D. = 1.4810inctm(38.227mn) Norrird Wall ThicJviess = 0.0720 ir>dhes(1.829 mn) Raw Area = 1.7227 sq.inches(1111.39 sq.mn) Hawn William Fonula CFador = 150 FLAN,Q Ressure Loss I-fyad Loss \Ajodty FLQ,N,Q Ressure Loss Haad Loss Mdocty (am) (psi/100ft) (ft/100ft) (ftJsec) (a.crr>'sea) 04 ai 100 m) (m 1o0 m) (co sec) 5.00 0.12 0.29 0.93 315 0.03 0.29 0.28 10.00 0.44 1.03 1.86 631 0.10 1.03 0.57 15.00 0.94 218 279 946 0.21 218 0.85 20.00 1.60 3.72 3.72 1252 0.36 3.72 1.14 25.00 242 5.61 4.66 1577 0.55 5.61 1.42 30.00 339 7.87 5.59 1893 0.77 7.87 1.70 35.00 4.52 10.46 6.52 2208 1.02 10.46 1.99 40.00 5.78 13.39 7.45 2523 1.31 13.39 227 45.00 7.19 16.65 8.38 2839 1.63 16.65 255 50.00 8.74 20.24 9.31 3154 1.98 20.24 2.84 55.00 10.43 24.14 10.24 3470 236 24.14 3.12 60.00 1226 28.36 11.17 3785 277 28.36 3.41 65.00 14.21 3288 1211 4101 3.22 3288 3.6g 70.00 16.30 37.72 13.04 4416 369 37.72 3.97 75.00 18.53 4285 13.97 4732 4.19 4285 4.26 80.00 20.86 48.28 14.90 5047 4.72 48.28 4.54 85.00 23.36 54.01 15.83 5362 5.28 54.01 4.83 90.00 25.97 60.04 1 6,76 5678 5.87 60.04 5.11 95.00 28.70 65.35 17.69 5993 6.49 66.35 5.39 100.00 31.56 7296 18.52 6309 7.14 7296 5.68 105.00 34.55 79.85 19.56 6624 7.82 79.85 5.96 110.00 37.66 87.03 20.49 6940 8.52 87.03 6.24 11500 1 40.89 1 94.49 1 21.42 1 7255 1 925 1 94.49 1 6.53 1 1/2"TYPE U' CCPPER TUBE-WATER FLOW AN D FRI CTI ON LOSS PER 100 FEET M,7Dd mQD. = 1.6270inches(41.326rrm) Norrind QD. = 1.6250imhes(41.275rrrn) MinimxnQD = 1.6230inches(41.224mn) Noninall.D. = 1.5050imhes(37.6174mn) Noninal Wall Thiel em = 0.0600 inches(1.524 con) Raw Area = 1.7789 sq.indhes(1147.71 sq.con) FbmnWilliarrsFixmla CFactor = 150 FLAN,Q Ressae Lass Egad Loss Mdodty FLAN,Q Rewe Lass Fwd Loss VAocty (am) 0/100ft) (ft/100ft) (ftJseo.) (cu.an'sea) (Id>W100m) (0100m) (m'seo) 5.00 0.11 0.26 0.90 315 0.03 0.26 0.27 10.00 0.41 0.95 1.80 631 0.09 0.95 0.55 15.00 0.87 202 271 946 0.20 202 0.82 20.00 1.48 3.44 3.61 1252 0.34 3.44 1.10 25.00 224 5.19 4.51 1577 0.51 5.19 1.37 30.00 3.14 7.27 5.41 1893 0.71 727 1.65 35.00 4.18 9.67 6.31 2206 0.94 9.67 1.92 40.00 5.35 1239 7.21 2523 1.21 1239 220 45.00 6.65 15.40 8.12 2839 1.50 15.40 247 50.00 8.09 18.72 9.02 3154 1.83 18.72 275 55.00 9.65 2232 9.92 3470 218 2232 3.02 60.00 11.33 26.22 10.82 3785 256 26.22 3.30 65.00 13.14 30.41 11.72 4101 297 30.41 357 70.00 15.08 34.88 1262 4416 3.41 34.88 3.85 75.00 17.13 39.63 13.53 4732 3.88 39.63 4.12 80.00 19.31 44.65 14.43 5047 4.37 44.65 4.40 85.00 21.60 49.95 15.33 5362 4.89 49.95 4.67 90.00 24.01 55.52 16.23 5678 5.43 55.52 4.95 95.00 26.54 61.36 17.13 5993 6.00 61.36 5.22 100.00 29.19 67.47 18.03 6309 &60 67.47 5.50 105.00 31.95 73.84 18.94 6624 723 73.84 5.77 110.00 34.82 80.48 19.84 6940 7.88 80.48 6.05 115.00 37.81 87.36 20.74 1 7255 1 &55 87.38 1 6.32 U.S customary units in this doarnent are the standard;the metric c units are provi ded for reference cnl y the values stated in each system are not ood egfaivalents. NIBDJINC WCRDFEADCLART9T• 1516MIOM83J'2i'Sr• BJ qU,IN465164740• LJS4• R-t 1.800.234.0227 m TEH SERACES R-t 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACER-t+1.574.295.3221• FAX-+1.574295.3455 • www.niboo.00m www.nibco.com AHEAD OF • 11/2"TYPE"M" COPPER TUBE-WATER FLOW AND MCTION LOSS PER 100 FEET MaarrunQD. = 1.6270irdies(41.326rrm) NamnalQD. = 1.6250irdes(41.275rrm) MininmQD. = 1.6230imhes(41.224rrm) Noninall.D. = 1.5270irdm(38.7858rrm) NarirelWallltrdviess = 0.0490irdies(1.2446rrm) Row Area = 1.83139q.irdies(1181.509q.rrm) HEmnWlliarrsFomula CFador = 150 R DvV,Q Ressure Loss Head Loss \Ajocity RD/V,Q F ressure Loss F�Loss Mblocity ((TM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.an'sec) 04:bv100m) (m100m) (m'sea) 5.00 0.11 0.25 0.88 315 0.02 025 0.27 10.00 0.38 0.89 1.75 631 0.09 0.89 0.53 15.00 0.81 1.88 263 946 0.18 1.88 0.69 20.00 1.38 3.20 3.50 1262 0.31 3.20 1.07 25.00 209 4.84 4.38 1577 0.47 4.84 1.33 30.00 2913 6.78 5.26 1893 0.66 6.78 1.60 35.00 3.89 9.02 6.13 2208 0.88 9.02 1.87 40.00 4.98 11.54 7.01 2523 1.13 11.54 214 45.00 620 14.35 7.88 2839 1.40 14.35 240 50.00 7.53 17.44 8.76 3154 1.70 17.44 267 56.00 8.99 20.69 9.64 3470 203 20.80 294 60.00 10.56 24.44 10.51 3785 2.39 24.44 3.20 65.00 1225 28.34 11.39 4101 2.77 28.34 3.47 70.00 14.05 3250 1226 4416 3.18 3250 3.74 75.00 15.96 36.92 13.14 4732 3.61 36.92 4.00 80.00 17.99 41.61 14.02 5047 4.07 41.61 4.27 85.00 20:13 46.55 14.89 5362 4.55 46.55 4.54 90.00 2238 51.74 15.77 5678 5.06 51.74 4.81 95.00 24.73 57.18 16.64 5996 5.59 57.18 5.(J7 100.00 27.20 6287 17.52 6309 6.15 51.87 5.34 105.00 29.77 61181 18.40 6514 6.73 61181 5.61 110.00 3245 74.99 19.27 6940 7.34 74.99 5.87 115.00 1 35.23 1 81.42 1 20.15 1 7256 1 7.97 1 81.42 1 6.14 COPPER" TUBE-WATER FLOVV AND •N LOSS PER 100 • Ma)dmmQD. = 2.1270irdm(54.026rrm) Nonind0Q = 21250imhes(53.975rrm) MirimmQD = 2.1230irdies(53.924rrm) Narinall.D. = 1.9590irdies(49.7586rrm) Narinail Wall ThidTwns = 0.0830inches(2.1082rrm) AavArea = 3.01419q.irdies(1944.589q.rrm) Haan W IIiarrs Form la CFador = 150 FLAN,Q Fressure Loss Head Loss mdocity RDN,Q Re�Loss Head Lass NMocity (CAM) osi/100ft) (ft/100ft) (ft./sec.) (cu.crosec.) 0,FW100m) (m'100m) (nY-) 10 0.11 0.25 1.06 631 0.03 0.25 0.32 20 0.41 0.95 213 1262 0.09 0.95 0.65 30 0.87 202 3.19 1893 0.20 202 0.97 40 1.48 3.43 4.26 2523 0.34 3.43 1.30 50 224 5.19 5.32 3154 0.51 5.19 1.52 60 3.14 7.27 639 3785 0.71 7.27 1.95 70 4.18 9.67 7.45 4416 0.95 9.67 227 69 5.35 1238 8.52 5047 1.21 1238 260 90 6.66 15.39 9.59 5678 1.51 15.39 292 100 8.09 18.71 10.64 6309 1.83 18.71 3.24 110 9.66 2232 11.71 6940 218 2232 3.57 120 11.34 26.21 1277 7570 257 26.21 3.89 130 13.16 30.40 13.84 8201 298 30.40 4.22 140 15.09 34.86 14.90 8832 3.41 34.86 4.54 150 17.15 69.61 1597 9463 3:88 69.61 4.87 160 19.33 44.63 17.03 10094 4.37 44.63 5.19 170 21.62 49.93 18.10 10725 4.69 49.93 5.52 180 24.04 55.50 19.16 11356 5.44 55.50 5.84 190 25.57 61.34 20.22 11986 6.01 61.34 6.16 200 1 29.22 1 67.44 1 21.29 1 12617 1 6.61 67.44 1 6.49 U.S Q5tcnary units i n this document are the standard;the rratri c units are provided for reference only the\d Lies stated i n each system are not ood equval ents. NIBMlNCWCRDFEADQIARTBS• 1516MICD_l33LWST.• BJ04WT,IN46516-1740• LISA- 1341.800.234.0277 • TITHSERACTBI9-11.888.446.4226• FAX1.690.234.0557• INTB:?VAl1CNALSERACER-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • COPPER" C E-WATER FLOW AND •N LOSS PER 100 FEET MadnmQD. = 21270indres(54.026rrm) NorrirelQD = 21250imhes(53.975rrm) MirrmmQD. = 21230imhes(53.924mn) Norrinall.D. = 1.9850indhes(50.419rrm) Norrird Wall Thidv>em = 0.0700 inches(1.778 mn) RoN Area = 3.0946 sq.inches(1996.54 sq.mn) HamnWlliansFonnla CFador = 150 FLAN,Q Ressure Loss Head Loss Mblocity FLQ,N,Q Ressure Loss Head Loss Mblocity (am) (psi/100ft) (ft/100ft) (ftJser-) (cu.arYsea) od:ai100m) (m100m) (cosec) 10 0.11 0.25 1.04 631 0.02 0.25 0.32 20 0.39 0.89 207 1262 0.09 0.89 0.63 30 0.82 1.89 3.11 1893 0.18 1.89 a95 40 1.39 3.22 4.15 2523 0.31 3.22 1.25 50 210 4.87 5.18 3154 0.48 4.87 1.58 60 295 6.82 6.22 3785 0.67 6.82 1.90 70 3.92 9.07 7.25 4416 0.89 9.07 2.21 80 5.02 11.61 8.29 5047 1.14 11.61 253 90 6.24 14.44 9.33 5678 1.41 14.44 284 100 7.59 17.55 10.37 6309 1.72 17.55 3.16 110 9.06 20.93 11.40 6940 205 20.93 3.48 120 10.64 24.58 1244 7570 241 24.58 3.79 130 1234 28.51 13.48 8201 279 28.51 4.11 140 14.15 3270 14.51 8832 3.20 3270 4.42 150 16.08 37.15 15.55 9463 3.64 37.15 4.74 160 18.13 41.86 16.59 10094 4.10 41.86 5.06 170 20.28 46.83 17.62 10725 4.59 46.83 5.37 180 2254 5205 18.66 11356 5.10 5205 5.69 190 24.92 57.53 19.70 11986 5.64 57.53 6.00 200 1 27.40 1 63.25 1 20.73 1 12617 1 6.20 63.25 6.32 COPPER" TUBE-WATER FLOW AND FRICTION •► 11 FEET Ma>ammQD. = 21270 inc hes(54.026 m») Noninal QD. = 21250 inches(53.975 mn) MlrinunQD. = 21230irdies(53.924mn) Nonrrinall.D. = 20090imhes(51.0286mn) NorrinalWAIThick>ess = 0.0580imhes(1.4732rrm) Raw Area = 3.1699sq.indres(2045.11sq.nm) Hazen WilliarrsFamAa CFador = 150 FLAN,Q Res ure Lass Head Loss Wocity R-ON,Q Ress<re Loss Head Lass Mdocity (G-W) (psi/100ft) (ft/10oft) (ftJser) (cu.crdsec) "loom) (m'100m) (m'sec.) 10 0.10 0.23 1.01 631 0.02 0.23 0.31 20 0.36 0.84 202 1252 0.08 0.84 0.62 30 0.77 1.78 3.04 1893 0.17 1.78 0.93 40 1.31 3.04 4.05 2523 0.30 3.04 1.23 50 1.98 4.59 5.06 3154 0.45 4.59 1.54 60 278 6.43 6.07 3785 0.63 6.43 1.85 70 3.70 8.55 7.08 4416 0.84 8.55 2.16 80 4.74 10.95 $.10 5047 1.07 10.95 247 90 5.89 13.62 9.11 5678 1.33 1362 278 100 7.16 16.55 10.12 6309 1.62 16.55 3.08 110 8.54 19.74 11.13 6940 1.93 19.74 3.39 120 10.03 23.19 1215 7570 227 23.19 3.70 130 11.64 26.89 13.16 8201 263 25.89 4.01 140 13.36 30.84 14.17 8832 3.02 30.84 4.32 150 15.17 35.04 15.18 9463 3.43 35.04 4.63 160 17.10 39.48 16.19 10094 3.87 39.48 4.94 170 19.13 44.17 17.21 10725 4.33 44.17 5.24 180 21.25 49.09 18.22 11356 4.81 49.09 5.55 190 23.50 54.26 19.23 11986 5.32 54.26 5.86 200 1 25.84 1 59.66 1 2024 1 12517 1 5.85 59.66 1 6.17 U.S customary units i n this doarnent are the standard;the rr etri c units are pravi ded for reference enl y the A Lies stated i n each system are not ood equvalents. NIBDJ INC WCR D FEADCLART9T• 1516 MIOM83J 2i'ST• BJ44gU IN 465164740• LJS4• R-t 1.800.234.0227 TEH SERACES PH 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACER-t+1.574.295.3221• FAX-+1.574295.3455 • www.niboo.ocrn www.nibco.com AHEAD OF • 21/2"TYPE"K' 00PPER.TUBE-WATER FLOW AND FRICTICIN LOSS PER 100FEET MaxanunaD = 2.6270indies(66.7258mn) Narinala0 = 2.5250imhes(66.675rrm) Minirr maD = 26230imhes(66.6242nTn) Nariral I.D. = 2.4350irches(61.849rrm) NorinalWall-hclrless = 0.0950irrhes(2.413rrm) RoN Area = 4.65689q.ir&,es(3004.380sq.n7n) HamnWilliarrsFcmula CRdor = 150 RD/V,Q Ressire Loss Head Loss malocity RD/V,Q Ressure Loss Fbad Loss \Ajocity (CAM) (psi/100ft) (fU100ft) (ft./sec.) (cu.crosec) 04:bv100m) (m100m) (m'seo.) 20 0.14 0.33 1.38 1262 0.03 0.33 0.42 40 0.51 1.19 276 2523 0.12 1.19 0.84 60 1.09 252 4.13 3785 0.25 252 1.26 80 1.86 4.30 5.51 5047 0.42 4.30 1.68 100 281 6.49 6.89 6309 0.64 6.49 210 120 3.94 9.10 8.27 7570 0.89 9.10 252 140 5.24 1210 9.65 8832 1.18 1210 294 160 6.71 15.49 11.02 10094 1.52 15.49 3.36 180 8.34 19.26 1240 11356 1.89 19.25 3.78 200 10.14 23.41 13.78 12617 229 23.41 4.20 220 1210 27.92 15.16 13879 274 27.92 4.62 240 14.21 3279 16.53 15141 3.21 3279 5.04 260 16.48 3803 17.91 16403 3.73 38.03 5.46 280 18.91 43.62 19.29 17664 4.28 43.62 5.88 300 21.48 49.55 20.67 18926 4.86 49.55 6.30 320 1 24.21 1 55.84 1 71.05 1 20188 1 5.48 1 55.84 1 6.72 COPPER" C E-WATER FLOW AND FRICTI ON • 11 FEET Maammaa = 2.6270indies(66.7258mn) NorrinalaD. = 2.6250imhes(66.675mn) MinimrnQD = 26230ind-es(66.6242mn) Nonire a = 24650imhes(62.611mn) Nom nal Wall Thidviess = 0.0800 i ndies(2.032 rrm) Row Area = 4.7723 sq.indies(3078.87 sq.rrm) HamnWilliarmFarrula CFactor = 150 RDN,Q %ss<re Loss Hgad Loss Wocity FLON,,Q Ressrre Loss Head Lass Melocity (GM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.crosec.) (IdwI00m) (0100m) (m'sea) 20 0.13 0.31 1.34 1252 0.03 0.31 0.41 40 0.48 1.12 269 2523 0.11 1.12 0.82 60 1.03 238 4.03 3785 0.23 238 1.23 80 1.75 4.05 5.38 5047 0.40 4.05 1.64 100 265 6.12 6.72 6309 0.60 6.12 205 12D 3.71 8.57 8.07 7570 0.84 8.57 246 140 4.913 11.40 9.41 8832 1.12 11.40 287 160 6.32 14.59 10.76 10094 1.43 14.59 3.28 180 7.86 18.15 1210 11356 1.78 18.15 3.69 200 9.55 2205 13.45 12617 2.16 2205 4.10 220 11.40 26.30 14.79 13879 2.58 200 4.51 240 13.39 30.90 16.13 15141 am 30.90 4.92 260 15.53 35.83 17.48 16403 3.51 35.83 5.33 280 17.81 41.09 18.82 17664 4.03 41.09 5.74 300 20.24 46.69 20.17 18926 4.58 4669 6.15 320 2281 1 5261 1 21.51 1 20188 1 5.16 1 5261 1 6.56 U.Sc storr aryunitsinthisdocu mentarethestan dard;therratri cunitsareplo,idedfor reference only the val Lies stated i n each system are riot exad equvA ents. m NIBMINGMIRLDFEADCLARTBS• 1516MICD_B3LWST.• BJ04WTlN46516-1740• U54• 1`1141.800.234.0227 TITH SEv10EB R-t 1.888.446.4226• FAX 1.800.234.0557• INTB:?VA-nCNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 21/2"TYPE"M" OOPPER TUBE-WATER FLOW AND FRCTI ON LOSS PEP,100 FEET MadrrunQD. = 26270indies(66.72%ran) NoninalQD. = 26250imhes(66.Mam) MirinunQD = 26230irxhes(66.6242mn) Norir>all.D. = 24950imhes(63.373rrm) Norrird Wall ThicJviess = 0.0650inches(1.651 n n) Raw Area = 4.8891 sq.indres(3154.27sq.mn) HamnWlliarrsFamla CRdor = 150 FLAN,Q Ressure Loss Head Loss Mblodty RQ,N,Q Ressure Loss Head Loss Mblocity (am) (psi/100ft) (ft/100ft) (ftJser-) (ai.arr'sea) od:ai100m) (m100m) (cosec) 20 0.13 0.29 1.31 1262 0.03 0.29 0.40 40 0.46 1.06 262 2523 0.10 1.06 0.80 60 0.97 224 3.94 3785 0.22 224 1.2D 80 1.65 3.82 5.25 5047 0.37 3.82 1.60 100 250 5.77 6.55 6309 0.56 5.77 200 120 3.50 8.08 7.87 7570 0.79 8.08 2.40 140 4.65 10.75 9.19 8832 1.05 10.75 2.80 160 5.96 13.76 10.50 10094 1.35 13.76 3.20 180 7.41 17.11 11.81 11356 1.66 17.11 3.60 200 9.01 20.79 13.12 12517 204 20.79 4.00 220 10.75 24.80 14.44 13879 243 24.80 4.40 240 1262 29.13 15.75 15141 286 29.13 4.80 260 14.64 33.78 17.06 16403 3.31 33.78 5.20 280 16.80 38.75 18.37 17664 3.8D 38.75 5.60 300 19.09 44.02 19.65 18925 4.32 44.02 6.00 320 21.51 49.60 21.00 20188 1 4.87 1 49.60 1 6.40 OOP PER E-WATER R_0W AND FRCTI ON • PER 11 Ma)dnunQD. = 3.1270indres(79.4258mn) NorrinalQD. = 3.1250inches(79.375rrrn) MirimanQD. = 3.1230indies(79.3242nm) Norrinall.D. = 29070ir&es(73.8378rrm) Nominal Wall Thickness = 0.1090incl a (27686rrrn) Row Area = 6.6371 sq.indnes(428201 sq.rrm) Hazen Williams FormAa CFador = 150 RQN,Q Pressure Loss Head Loss \kiodty RAN,Q Ressure Lass Head Lass Md odty (am) 0/100ft) (ft/100ft) MJsea) (ai.cnYsec-) (IFa/100m) (0100m) (rrr'sec.) 25 0.09 0.21 1.21 1577 0.02 0.21 0.37 50 0.33 0.76 242 3154 0.07 0.76 0.74 75 0.70 1.61 3.63 4732 0.16 1.61 1.11 10D 1.19 274 4.83 6309 0.27 274 1.47 125 1.79 4.14 6.04 7886 0.41 4.14 1.84 150 251 5.8D 7.25 9463 0.57 5.80 221 175 3.34 7.72 8.46 11040 0.76 7.72 2.58 2DD 4.28 9.88 9.67 12517 0.97 9.88 2.95 225 5.33 12.29 10.88 14195 1.20 1229 3.32 250 6.47 14.94 1208 15772 1.46 14.94 3.68 275 7.72 17.82 13.29 17349 1.75 17.82 4.05 30D 9.07 20.93 14.50 18925 205 20.93 4.42 325 10.52 24.27 15.71 20503 238 24.27 4.79 350 1207 27.83 16.92 22080 273 27.83 516 375 13.72 31.62 18.13 23658 3.10 31.62 5.53 400 15.46 35.63 19.34 25235 3.50 35.63 5.89 425 1 17.29 1 39.86 1 20.54 1 26612 3.91 39.86 6.26 U5 astorroy units i n this doanriert are the standard;the met r c units are provided for reference cnl y The\rJ ues stated i n each system are riot exact equivalents NIBDJ INC WCRD FEADCLART9T• 1516 MIOM83J 2i'ST• BJ44gU IN 465164740• LJS4• R-t 1.800.234.0227 m T67-I SERACT;S PR 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.riboo.00m www.nibco.com AHEAD OF • 3'TYPE"U' COPPER TUBE-WATER FLOW AND FRI CTI ON LOSS PER 100 FEET mcwff nQD. = 3.1270ir&es(79.4258mn) NomrelQD = 3.1250inches(79.375rrm) MirimmQD = 3.1230imhes(79.3242mn) Norrind I.D. = 29450imxhes(74.803rm) Nmir� V\dl-hclrless = 0.090Din±es(2.286rrm) Ram Area = 6.8118sq.irches(4394.69sq.nm) Hazen WiIIiarrsFomula CFactor = 150 RD/V,Q RessLre Loss Head Loss malocity RD/V,Q Ressure Loss Fbad Loss W ocity (am) (psi/100ft) (ft/1o0ft) (ft./sec.) (cu.cn'sec) 04:bv100m) (m100m) (m'seo.) 25 0.09 0.20 1.18 1577 0.02 020 0.36 50 0.31 0.71 235 3154 0.07 0.71 0.72 75 0.65 1.51 3.53 4732 0.15 1.51 1.08 100 1.11 257 4.71 6309 0.25 257 1.44 125 1.68 3.89 5.89 7886 0.38 3.89 1.79 150 236 5.45 7.06 9463 0.53 5.45 215 175 3.14 7.25 824 11040 0.71 725 251 200 4.02 9.28 9.42 12617 0.91 9.28 287 225 5.00 11.54 10.60 14195 1.13 11.54 3.23 250 608 14.02 11.77 15772 1.37 14.02 3.59 275 725 16.72 1295 17349 1.64 16.72 3.95 300 8.52 19.65 14.13 18926 1.93 19.65 4.31 325 9.88 2278 15.31 20503 223 2278 4.67 350 11.33 25.13 16.48 22080 256 26.13 5.02 375 1288 29.69 17.66 23658 291 29.69 5.38 400 14.51 33.45 18.84 25715 3.28 33.45 5.74 425 1 1624 1 37.42 1 20.02 1 26812 1 3.67 37.42 610 COPPER" C E-WATER FLOW AND FRICTI ON •► PER 100 FEET MadffmoD. = 3.1270indies(79.4258rrm) NorrirdQD = 3.1250inches(79.375rrm) MirimmQD = 3.1230indies(79.3242nTn) Norrird I.D. = 29810imxhes(75.7174rrm) NmirdVValllhidTe% = 0.072oimhes(1.8288rrm) RavArea = 6.97939q.ir&es(4502799q.rrm) HEo3nWilliarrsFcmula CRdor = 150 FLAN,Q Ressure Loss Head Loss malocity RD/V,Q Ressure Loss Hied Lass Mdocity (G:m) (psi/1ooft) (ft/100ft) (ft./sec.) (cu.cn'sec) OFwl00m) (m100m) (m'seo.) 25 0.08 0.19 1.15 1577 0.02 0.19 0.35 50 0.29 0.67 230 3154 0.07 0.67 0.70 75 0.52 1.42 3.45 4732 0.14 1.42 1.05 100 1.05 243 4.60 6309 0.24 243 1.40 125 1.59 3.67 5.75 78% 0.36 3.67 1.75 150 222 5.14 690 9463 0.50 5.14 210 175 296 6.83 8.04 11040 0.67 6.83 245 200 3.79 8.75 9.19 12617 0.86 8.75 280 225 4.71 10.88 10.34 14195 1.07 10.88 3.15 250 5.73 13.22 11.49 15772 1.30 13.22 3.50 275 6.83 15.76 1264 17349 1.55 15.76 3.85 300 8.03 18.52 13.79 18M 1.82 18.52 4.20 325 9.31 21.47 14.94 20503 2.11 21.47 4.55 350 10.63 24.63 16.09 22080 242 24.63 4.90 375 1214 27.98 17.24 23653 275 27.98 5.25 400 13.69 31.53 18.39 25235 3.09 31.53 5.60 425 1 15.30 1 3527 1 19.54 1 26812 3.46 35.27 5.95 U.S aistorrnry units in th s docun al are the standard;the metric units are pravi ded for reference ody.-ihe values stated in each systemare not exact equvalents. ® NIBMINCWCRDFEADCLARTBS• 1516MICOLB3LWSL• BJ04WT,IN46516d740• LISA- R41.800.234.0227 TEH SERACEB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.2951.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 31/Z'TYPE"K' COPPER TUBE-WATER FLOW AND FRICTICN LOSS PER 100FEET MahammQD. = 3.6270indies(921258rrm) Nordrd0D. = 36250imhes(92075rrm) MirimmQD. = 3.6230indies(920242mn) Norrinai l.D. = 33850indies(85.979mn) Nominal Wall lhidvhecs = 0.1200 indies(3.048 mn) Rw Area = 6.9993 sq.inches(5805.97 sq.mn) HamnWlliarrsFoamda CRdor = 150 RAN,Q Ressure Lass Farad Loss Mblodty FLAN,Q Ressure Loss Fwd Lass Mblocity (C-M) (psi/100ft) (ft/100ft) (ftJsea) (cu.arYsea) 04ai100m) (0100m) (cosec) 25 0.04 0.10 0.89 1577 0.01 0.10 0.27 50 0.16 0.36 1.78 3154 0.04 0.36 0.54 75 0.33 0.77 267 4732 0.08 0.77 a81 100 0.57 1.31 3.57 6309 0.13 1.31 1.09 125 0.85 1.98 4.46 7886 0.19 1.98 1.36 150 1.20 277 5.35 9463 0.27 277 1.63 175 1.59 3.68 6.24 11040 0.36 3.68 1.90 200 204 4.71 7.13 12617 0.46 4.71 217 225 254 5.86 8.02 14195 0.57 5.86 244 250 3.09 7.12 8.91 15"2 0.70 7.12 2.72 275 3.63 &49 9.80 17349 0.83 8.49 299 300 4.33 9.98 10.70 18925 0.98 9.98 3.26 325 5.02 11.57 11.59 2003 1.13 11.57 3.53 350 5.76 13.27 1248 22080 1.30 1327 3.80 375 6.54 1508 13.37 23668 1.48 15.08 4.07 400 7.37 16.99 14.26 25735 1.67 16.99 4.35 425 &25 19.01 15.15 25812 1.87 19.01 4.62 450 9.17 21.12 16.04 28389 207 21.12 4.89 475 10.13 23.35 16.93 29966 229 23.35 5.16 500 11.14 25.67 17.83 31543 252 25.67 5.43 525 1220 28.10 1&72 33121 276 28.10 5.70 550 13.29 30.62 19.61 34696 3.01 30.62 5.98 575 14.43 33.25 20.50 36275 326 33.25 6.25 600 1 15.62 1 35.97 1 21.39 1 37852 3.53 35.97 6.52 •"•'TUBE-WATER FLOW ON •S 11 FEET MadmanOD. = a6270ind>es(921258mn) NorrinalQD. = a e250indies(92075mn) MirimmQD. = 3.6230indies(920242rrm) Norrinall.D. = 3.4250imhes(86.995nm) Nomnal Wall ThidToss = 0.1000imhes(2540rrm) Row Area = 9.2132sq.indhes(5944.00sa.rrm) HamnWlliansFarnda CFador = 150 FLO.N,Q Ressure Lass Haad Loss Wocity FLAN,Q %ssre Loss Fad Lass \b«ity (GM) (ps000ft) (ft/1o0ft) (ftJseo) (cu.crdsea) "loom) (m100m) (m'sea) 25 0.04 0.09 0.87 1577 0.01 0.09 0.27 50 0.15 0.34 1.74 3154 0.03 0.34 0.53 75 0.31 0.73 261 4732 0.07 0.73 0.80 100 0.53 123 3.48 6309 0.12 1.23 1.06 125 0.81 1.87 4.35 7886 0.18 1.87 1.33 150 1.13 261 5.22 9463 0.26 261 1.59 175 1.51 3.48 6109 11040 0.34 3.48 1.86 200 1.93 4.45 6.96 12517 0.44 4.45 212 225 240 5.53 7.84 14195 0.54 5.53 239 250 291 6.73 8.71 15772 0.66 6.73 265 275 3.48 8.02 9.58 17349 0.79 &02 292 300 4.09 9.42 10.45 18925 0.92 9.42 318 325 4.74 10.93 11.32 20503 1.07 10.93 3.45 350 5.44 1253 1219 22080 1.23 1253 3.71 375 6.18 14.24 1306 23658 1.40 14.24 3.98 400 6.96 16.05 13.93 25235 1.57 16.05 4.25 425 7.79 17.95 14.80 26812 1.76 17.95 4.51 450 8.66 19.95 15.67 283&9 1.96 19.95 4.78 475 9.57 22.05 16.54 29966 216 2205 5.04 500 10.52 24.25 17.41 31543 238 24.25 5.31 525 11.52 26.54 1&28 33121 261 1 25.54 557 550 1255 28.92 19.15 34658 284 21192 5.84 575 13.63 31.40 20.02 36275 308 31.40 6.10 600 1 14.75 1 33.97 1 20.89 37852 334 33.97 6.37 U.S a hstanary cdnits in this d=Trent are the standard;the rretri c snits are pra Aded far reference a9y.The vd ues stated in each system are not exact ec}u\rderta NIBOJ INC WCR D FEADCLART9T• 1516 MIU183J 2i'ST• BJ44gU IN 465164740• Lls4• R-t 1.800.234.0227 TT37-I SERACES PH 1.888.446.4226• FAX 1.800.234.0557• INTffi Al1QVALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 wwwAboo.com www.nibco.com AHEAD OF • 31/2"TYPE"M" COPPER TUBE-WATER FLOW AND FRICTION LOSS PER 100 FEET McwffmQD. = 3.6270indres(92.125Bmn) NomnalQQ = 3.6250imhes(92.075rrm) MirimmQD = 3.6230imhes(92.0242mn) NorrirEd I.D. = 3.4590imhes(87.8586rrm) Narin V\d l-h cl zless = 0.083o i n&es(21082 rrm) RoN Area = 9.397 sgJndies(6052.59 sq.rrm) HamnV\AIIiarrsFomula CFador = 150 RD/V,Q Resare Loss Head Loss malocity RD/V,Q Ressure Loss Hach Loss \Ajocity (MIA) (psi/10m) (ft/100ft) (ft./sec.) (cu.an'sec) 04:bv100m) (m100m) (rry-) 25 0.04 0.09 0.85 1577 0.01 0.09 0.26 50 0.14 0.33 1.71 3154 0.03 0.33 0.52 75 030 0.69 256 4732 ON 0.69 0.78 100 0.51 1.18 3.41 6309 0.12 1.18 1.04 125 0.77 1.78 4.27 7886 0.17 1.78 1.30 150 1.08 249 5.12 9463 0.24 249 1.56 175 1.44 3.31 5.97 11040 0.32 3.31 1.82 200 1.84 4.24 6.83 12617 0.42 4.24 208 225 229 5.27 7.68 14195 0.52 5.27 234 250 278 6.41 8.54 15772 0.63 6.41 260 275 3.31 7.65 9.39 17349 0.75 765 286 300 3.89 8.98 10.24 18M 0.86 8.98 3.12 325 4.52 10.41 11.10 20503 1.02 10.41 3.38 350 5.18 11.94 11.95 22080 1.17 11.94 3.64 375 589 13.57 1280 23658 1.33 13.57 3.90 400 663 15.29 13.66 25715 1.50 15.29 4.16 425 7.42 17.11 14.51 26812 1.68 17.11 4.42 450 8.25 19.02 15.36 28389 1.87 19.02 4.6B 475 9.12 21.02 16.22 29966 2.06 21.02 4.94 500 10.03 23.11 17.07 31543 2.27 23.11 5.20 525 10.98 25.29 17.92 33121 248 25.29 5.46 550 11.96 27.56 18.78 34698 271 27.56 5.72 575 1299 29.93 19.63 36275 294 29.93 5.98 600 1 14.06 1 3238 1 20.49 1 37652 3.18 3238 6.24 4 COPPER" r • AND ON •► 100FEET MaammQa = 4.1270indies(104.8258mn) NorrinalQD. = 4.1250indies(104.775mn) MirimmQa = 4.1230indies(104.7242mn) Nonired I.a = a8s70irdm(97.9678mn) Nomrral VVal I Thidviess = 0.1340 i mhes(3.4036 nm) Raw Area = 11.6839 sq.Indies(75;18.01 sq.rrm) Ha2enV\AlliarrsFromula CFador = 150 RDN,Q Ressure Loss Head Loss \kiodty RON,Q Ressure Loss Head Lass Veladty (GM) 0si/100ft) (ft/100ft) (ft./sec.) (cu.cnYseo) "loom) (m'1DDm) (rTy-) 50 0.08 0.19 1.37 3154 0.02 0.19 0.42 100 0.30 0.69 275 6309 ON 0.69 0.84 150 0.63 1.47 4.12 9463 0.14 1.47 1.26 200 1.08 250 5.49 12617 0.24 250 1.67 250 1.64 3.77 686 15772 0.37 3.77 209 300 229 529 8.24 18926 0.52 5.29 251 350 3.05 7.03 9.61 22080 0.69 7.03 293 400 391 9.00 10.98 25235 0.88 9.00 3.35 450 4.86 11.19 12.36 28389 1.10 11.19 3.71 500 5.9D 13.60 13.73 31543 1.34 13.60 4.18 550 7.04 16.23 15.10 34696 1.59 1623 4.60 600 8.27 19.06 1648 37852 1.87 19.06 5.02 650 9.60 2210 17.85 41006 2.17 2210 5.44 700 11.01 25.35 19.22 44161 249 25.35 5.86 750 1251 28.80 20.59 47315 283 28.80 6.28 800 14.10 3245 21.97 50469 3.19 3245 6.70 850 15.77 36.30 23.34 53624 3.57 3630 7.11 900 17.53 40.35 24.71 58778 3.97 40.35 7.53 950 19.38 1 44.60 1 26.09 1 59732 1 4.38 44.60 7.95 10D0 21.31 49.04 27.46 63087 I 4.82 49.04 8.37 U.S.aastaray twits in this doaarrent are the starxlard;the metric Lints are provided for reference only.the values stated in each system are not ead equvi ents. m NIBMINCVVCRDHEADCLARTBS• 1516MICD_B3LWSr- BJ04WT,IN46516d740• LISA- R41.800.234.0227 TEH SERACEB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE RR+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • TYPE" COPPER" C E-WATER FLOW AND ON •► 11 FEET MadnmQD. = 4.1270indres(104.8258rrm) NorrirelQD. = 4.1250imhes(101.775rrm) MirimrnQD. = 4.1230imhes(104.7242rrrn) Norrinell.D. = 3.905oin&m(99.187mn) Norrird Wall Thidviem = 0.1100 inches(2794 mn) flow Area = 11.9766 sq.ind-es(7726.80 sq.rrm) Ha enWilliansFonnla CFador = 150 FLAN,Q Ressure Loss Read Loss Mblocity RDN,Q Ressure Loss Head Lass \Mocity (CFM) (psi/10oft) (ft/10oft) (ftJser-) (a.ansea.) od:ai100m) (m1oom) (cosec) 50 0.08 0.18 1.34 3154 0.02 0.18 0.41 100 0.28 0.65 266 6309 0.06 0.65 0.82 150 0.60 1.38 4M 9463 0.14 1.38 1.22 200 1.02 235 5.36 12617 0.23 235 1.63 250 1.54 3.55 6.70 15772 0.35 3.55 204 300 216 4.98 8.04 18926 0.49 4.98 2.45 350 287 662 9.38 22080 0.65 6.62 2.86 400 3.68 8.48 10.72 25235 0.83 8.48 3.27 450 4.57 10.54 1205 28389 1.03 10.54 3157 500 5.56 12.81 13.39 31543 1.26 1281 4.08 550 6.63 15.28 14.73 34698 1.50 15.28 4.49 600 7.79 17.95 16.07 37852 1.76 17.95 4.90 650 9.04 20.81 17.41 41006 204 20.81 531 700 10.37 23.87 18.75 44161 234 23.87 5.72 750 11.78 27.12 20.09 47315 266 27.12 6.12 800 13.27 30.56 21.43 50469 3.00 30.56 6.53 850 14.85 34.18 2277 53624 3.36 34.18 6.94 900 16.51 38.00 24.11 56778 3.73 3800 7.35 950 18.25 41.99 25.45 59932 4.13 41.99 7.76 1000 1 20.07 1 46.17 1 26.79 1 63087 1 4.54 46.17 1 8.17 ' COPPER" TUBE-WATER FLOVV AND FRICTION •► PER 100 FEET MaanunOD. = 4.1270irches(104.8258con) NorvinalQD. = 4.1250irches(104.775mn) MininumQD. = 4.1230indhes(104.7242rrm) Noninall.D. = 3.9350imhes(99.949rrm) NomnalWdIThiclTess = 0.0950imhes(2413rrrn) Raw Area = 121613sq.irxies(7845.87sq.rrm) Hazen WlliarrsFamAa CFador = 150 FLON,Q Ressue Lass Head Loss \klocity FLO,N,Q Ress<re Loss Haad Lass Mdoety (GM) (psi/10Dft) ft/10M) (ftJsec.) (cu.crdsec.) "loom) (m'100m) (m'sea) 50 0.08 0.17 1.32 3154 0.02 0.17 0.40 100 0.27 0.63 264 6309 0.06 063 0.80 150 0.58 1.33 3.96 9463 0.13 1.33 1.21 200 0.98 227 5.28 12517 022 227 1.61 250 1.48 3.42 6.60 15772 0.34 3.42 201 300 208 4.80 7.91 18925 0.47 4.80 241 350 277 6.38 9.23 22080 0.63 6.38 2.81 400 3.54 8.17 10.55 25235 0.80 8.17 3.22 450 4.41 10.15 11.87 28389 1.00 10.15 3.62 500 5.36 1234 13.19 31543 1.21 1234 4.02 550 6.39 14.72 14.51 34698 1.45 14.72 4.42 600 7.51 17.29 15.83 37852 1.70 17Z 4.82 650 8.71 20.05 17.15 41006 1.97 20.05 5.23 70D 9.99 23.00 1&47 44161 226 23.00 5.63 750 11.35 26.13 19.79 47315 257 25.13 6.03 800 1279 29.44 21.11 50469 289 29.44 6.43 850 14.31 3293 2242 53624 3.24 3293 6.83 9DD 15.91 36.61 23.74 56778 3.e0 36.61 7.24 950 17.58 40.46 25.06 59932 3.96 40.46 7.64 1000 1 19.33 1 44.49 1 25.38 1 63087 1 4.37 44.49 1 8.04 U.S.a isto nary units in this doament are the standard;the metric nits are provided for refere-ce only.The val Lies stated in each system are riot exad equ\rdents. NIBDJ INC WCR D FEADCLART9T• 1516 MIOM83J i'ST• BJ44gU IN 46516.4740• L1S4• R-t 1.800.234.0227 m TB]HSERACESPH 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACER-t+1.574.295.3221• FAX.+1.574.295.3455 www.riiboo.00m www.nibco.com AHEAD OF • S'TYPE"K' COPPER TUBE-WATER FLOW AND FRI CTI ON LOSS PER 100 FEET mcwff nQD. = 5.1270indies(130.7258rrm) NomnalQD = 5.1250imhes(130.175rrm) MirrmmQD = 5.1230imhes(130.1242nTn) Norrinall.D. = 4.8050imhes(122047rrm) mrral�V No Ilhclviess = 0.1600irdies(4.064rrm) Ram Area = 18.1333sq.indies(11698,87sq.rrm) HEmnWilliarrsForrTula CFador = 150 RDN,Q Resa re Loss Head Loss malocity RD/V,Q Ressure Loss Hid Loss Mblocity (am) (psi/1o0ft) (ft/100ft) (ft./sec.) (cu.crosec) 04:bv100m) (m100m) (m'sea) 50 0.03 ON 0.88 3154 0.01 ON 0.27 100 0.10 0.24 1.77 6309 0.02 0.24 0.54 150 0.22 0.50 265 9463 0.05 0.50 0.81 200 0.37 0.86 3.54 12617 0.08 0.86 1.08 250 0.55 1.30 4.42 15772 0.13 1.30 1.35 300 0.79 1.81 5.31 18M 0.18 1.81 1.62 350 1.05 241 6.19 22080 0.24 241 1.89 400 1.34 3.09 7.08 25?35 0.30 3.09 216 450 1.67 3.84 7.96 28389 0.38 3.84 243 500 2013 4.67 &85 31543 0.46 4.67 270 550 242 557 9.73 34698 0.55 5.57 297 600 284 6.54 10.62 37852 0.64 6.54 3.24 650 3.29 7.59 11.50 41006 0.75 7.59 3.51 700 3.78 8.70 1239 44161 0.85 &70 3.77 750 4.29 9.89 13.27 47315 0.97 9.89 4.04 800 4.84 11.14 14.15 50469 1.09 11.14 4.31 850 5.41 1246 15.04 53624 1.22 1246 4.58 900 6.02 13.85 15.92 56778 1.36 13.85 4.85 950 665 15.31 16.81 59932 1.50 15.31 5.12 1000 7.32 16.83 17.69 63087 1.65 16.83 5.39 1050 &01 1&42 18.58 65241 1.81 1&42 5.66 1100 &73 20.08 19.46 69395 1.97 20.08 5.93 1150 1 9.48 1 21.80 1 20.35 1 72550 1 214 1 21.80 6.20 COPPER" TUBE WATER FLOW ON •► 11 FEET Madm.mQD. = 5.1270irxhes(130.2258rrm) NarinalQe = 5.1250imhes(130.175rrm) MinimnQD = 5.1230indres(130.1242mn) Narinall.D. = 4.8750indies(123.825rrm) Nomr d Wall ThidT ess = 0.1250 i mhes(3.175 rrm) Rav Area = 18.6655 sq.i ndies(1204222 sq.rrrn) HamnWiIIiarrsFcnrula CFador = 150 RDN,Q Resa re Loss Head Loss \kiodty RDN,Q Re�Loss Hbad Lass Mblodty (CAM) (ps/100ft) (ft/100ft) (ft./sec.) (cu.crosec.) OFwlo0m) (m100m) (m'sec) 50 0.03 0.06 0.86 3154 0.01 0.06 0.26 100 0.10 0.22 1.72 6309 0.02 0.22 0.52 150 0.20 0.47 258 9463 0.05 0.47 0.79 200 0.35 0.80 3.44 12617 0.08 0.80 1.05 250 0.52 1.21 4.30 15772 0.12 121 1.31 300 0.73 1.69 5.16 18M 0.17 1.69 1.57 350 0.98 225 6.02 22080 0.22 225 1.83 400 1.25 288 6.88 25235 0.28 288 210 450 1.55 3.58 7.73 28389 0.35 3.58 236 500 1.89 4.35 &59 31543 0.43 4.35 262 550 225 5.19 9.45 34698 0.51 5.19 288 600 265 6.10 10.31 37852 0.60 6.10 3.14 650 3.07 7.07 11.17 41006 0.69 7.07 3.41 700 3.52 all 12.03 44161 0.80 8,11 3.67 750 4.00 9.21 1289 47315 0.91 9.21 3.93 800 4.51 10.38 13.75 50469 1.02 10.38 4.19 850 5.05 11.61 14.61 53624 1.14 11.61 4.45 900 5.61 1291 15.47 56778 1.27 1291 4.72 950 620 14.27 16.33 599M 1.40 14.27 4.98 1000 682 15.69 17.19 63087 1.54 15.69 5.24 1050 7.46 17.17 1&05 66241 1.69 17.17 5.50 1100 &13 1 8,71 18.91 69395 1.84 1&71 5.76 1150 &83 2D.32 19.77 71550 2.00 20.32 6.02 U.S.aastaray twits in the doaarrent are the starxlard;the metric Lhts are provided for referenoe only the values stated in each system are not ead egtivd eats. mNIBMlNC WCRDFEADQJARTBS• 1516MICOLB3LWSL• BJ04WT,IN46516-1740• LISA- 1341.80D.234.0227 • TITH SERACEB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.2951.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 5"TYPE"M" COPPER TUBE-WATER FLOW AN D FRI CTI CN LOSS PER 100 FE17 Ma>amrnQD. = 5.1270indies(130.2258rrm) Norrina0l).. = a1250inches(130.175rrm) MinimrnQD = 5.1230imhes(130.1242rrm) Norrird I.D. = 4.9070imhes(124.6378rrm) Norrird Wail ThicJviess = 0.1090irches(27686rrm) Flans Area = 18.9113sq.irxfres(12200.839q.rrm) HamnWlliarrsFamla CFador = 150 FLAN,Q Ressure Loss Ftyad Loss Vjocity FLAN,Q Ressure Loss Fsad Loss Mblocity (am) (psi/100ft) (ft/100ft) (ftJsec) (cu.cm sea) 04 ai 100 m) (m 100 m) (rr sec) 50 0.03 0.06 0.85 3154 0.01 0.06 0.25 100 0.09 0.21 1.70 6309 0.02 0.21 0.52 150 0.20 0.45 254 9463 0.04 0.45 a78 200 0.34 0.77 3.39 12617 0.08 0.77 1.03 250 0.51 1.17 4.24 15772 0.11 1.17 1.29 300 0.71 1.64 5.09 18926 0.16 1.64 1.55 350 0.95 218 5.94 22080 021 218 1.81 400 1.21 279 6.79 25235 0.27 279 207 450 1.51 3.47 7.63 28389 0.34 3.47 233 500 1.83 4.22 8.48 31543 0.41 4.22 2.59 560 218 5.03 9.33 34698 0.49 S03 284 600 256 5.91 10.18 37852 0.58 5.91 3.10 650 297 6.85 11.03 41006 0.67 585 3.36 700 3.41 7.86 11.88 44161 0.77 7.86 3.62 750 3.88 &93 1272 47315 0.88 &93 3.88 800 4.37 10.06 13.57 50469 0.99 10.06 4.14 850 4.89 11.25 14.42 53524 1.11 11.25 4.40 900 5.43 1251 15.27 56778 1.23 1251 4.65 950 6.01 13.82 16.12 59932 1.36 13.82 4.91 1000 6.60 15.20 16.97 63067 1.49 15.20 5.17 1050 7.23 16.63 17.81 66241 1.64 16.63 5.43 1100 7.88 18.13 1&66 69395 1.78 1&13 5.69 1150 1 &56 1 19.68 1 19.51 1 72550 1 1.94 1 19.68 1 5.95 • OOPPER TUB E WATER • AN ON A PER 100 MET MabmamQD. = 6.1270indies(155.6258rrm) Nomrrd QD. = 6.1250imhes(155.575rrm) MininumQD. = 6.1230indies(155.5242rTm) Norrird I.D. = 5.7410imhes(145.8214mn) Norrinal Wall Th ess = 0.1920inches(4.8768m-n) Raw Area = 25.8860sq.inch%(1670D.61 sq.rnn) HamWilliarrsFormla CFador = 150 FLAN,Q Ressae Lass FLaad Loss Mblocity FLOW,Q Resstre Lass Head Loss Mdocity (am) 0/100ft) (ft/100ft) (ftJsea) (cu.an'sea) Qd:w100m) (0100m) (m'seo) 10D 0.04 0.10 1.24 6309 0.01 0.10 0.38 200 0.16 0.36 248 12617 0.04 0.36 0.76 300 0.33 0.76 3.72 18925 0.07 0.76 1.13 400 0.56 1.30 4.96 25235 0.13 1.30 1.51 500 0.85 1.96 6.20 31543 0.19 1.96 1.89 600 1.19 275 7.44 37852 0.27 275 227 700 1.59 3.66 8.66 44161 0.36 3.66 264 800 204 4.69 9.92 50469 0.46 4.69 3.02 900 253 5.83 11.15 56778 0.57 5.83 3.40 1000 3.08 7.08 1239 63067 0.70 7.08 3.78 1100 3.67 &45 13.63 69395 0.83 &45 4.16 1200 4.31 9.92 14.87 75704 0.98 9.92 4.53 1300 5.00 11.50 16.11 82013 1.13 11.50 4.91 1400 5.74 13.19 17.35 86321 1.30 13.19 5.29 1500 6.52 14.99 1&59 94630 1.47 14.99 5157 1600 7.35 16.89 19.83 100939 1.66 16.89 6.04 1700 &22 18.90 21.07 107247 1.86 1&90 6.42 1800 1 9.14 1 21.00 1 2231 1 113556 1 207 21.00 1 6.80 U.S c sta rory units in this doarnent are the standard;the rr etd c units are provi ded for reference only The values stated in each system are not ood ecluvalents. NIBDJ INC WORD FEADCLART9T• 1516 MIOM83J 2i'S r• BJ44gU IN 46516.4740• LJS4• R-t 1.800.234.0227 TEH SERACES PH 1.888.446.4226• FAX 1.800.234.0557• INTB3VATICNALSERAC R-t+1.574.295.3221• FAX-+1.574295.3455 www.niboo.00m www.nibco.com AHEAD OF • • COPPER" C E-WATER FLOW AND ON • 11 FEET mcwff nQD. = 6.1270indm(155.6258rrm) NomrelQQ = 6.1250imhes(155.575rrm) Mir9mmQD = 6.1230imhes(155.5242mn) Norriral l.D. = 5.8450imhes(148.463rrm) NarirelWall-hclrlem = 0.1400ird-es(3.556rrm) RavArea = 26.83249q.ir&es(17311.17sq.rrm) Hawn WilliarrsForm6a CFador = 150 RIJN,Q Pressure Loss Head Lass malocity RDJV,Q Ressure Loss Ft Loss \Mocity (CAM) (ps/100ft) (ft/100ft) (ft./sec.) (cu.cn'sec) OFwl00m) (m100m) (m'seo.) 100 0.04 0.09 120 6309 0.01 0.09 0.36 200 0.14 0.33 239 12617 0.03 0.33 0.73 300 0.30 0.70 3.59 189266 ON 0.70 1.09 400 0.52 1.19 4.78 25715 0.12 1.19 1.46 500 0.78 1.80 5.98 31543 0.18 1.80 1.82 600 1.09 252 7.17 37852 0.25 252 219 700 1.46 3.35 8.37 44161 0.33 3.35 255 800 1.87 4.29 9.57 50469 0.42 4.29 292 900 232 5.34 10.76 56778 0.52 5.34 3.28 1000 282 6.49 11.96 63087 0.64 6.49 3.64 1100 3.36 7.74 13.15 69395 0.76 7.74 4.01 1200 3.95 9.09 14.35 75704 0.89 9.09 4.37 130D 4.58 10.54 15.54 82013 1.04 10.54 4.74 1400 5.26 1209 16.74 88321 1.19 1209 5.10 150D 598 13.74 17.94 94630 1.35 13.74 5.47 160D 6.73 15.48 19.13 100939 1.52 15.48 5.83 170D 7.53 17.32 20.33 107247 1.70 17.32 6.20 1800 1 8.38 1 19.25 1 21.52 1 113556 1 1.89 1 19.25 1 6.56 ' ••"E'TUBE-WATER FLOW AND FRCTI ON •► PER 100FEET MadnunOD. = 6.1270ird-es(155.6258rrm) NarinalQD. = 6.125Dindies(155.575rm) MinimmQD. = 6.1230irches(155.5242rrm) Norrinall.a = 5.8810imhes(149.3774rrm) Norri nal Wall Thidviess = 0.1220 i ndies(3.0988 rrm) Row Area = 27.1639 sq.ir>dm(17525.07 sq.rrm) HamnWilliarrsRxrn.da CFador = 150 R13N Q %ssre Loss Head Lnss \docity RDN,Q Ressrre Loss Head Lass Malocity (GM) (psi/100ft) (fU100ft) (ft./sec.) (cu.aTYsec.) (Idw100m) (0100m) (m'sec.) 100 0.04 0.09 1.18 6309 0.01 0.09 0.36 200 0.14 0.32 236 12617 0.03 0.32 0.72 300 0.29 0.68 3.54 189M ON 0.68 1.08 400 0.50 1.16 4.72 25235 0.11 1.16 1.44 500 0.76 1.75 5.91 31543 0.17 1.75 1.80 600 1.06 245 7.09 37&52 0.24 245 216 700 1.41 3.26 8.27 44161 0.32 3.26 252 800 1.81 4.17 9.45 50469 0.41 4.17 288 900 225 5.18 10.63 56778 0.51 5.18 3.24 1000 274 6.30 11.81 63087 0.62 6.30 3.60 1100 3.27 7.51 12.99 69395 0.74 7.51 3.96 12DD 3.84 8.82 14.17 75704 0.87 8.82 4.32 1300 4.45 10.23 15.35 82013 1.01 10.23 4.68 140D 5.10 11.74 16.54 88321 1.15 11.74 5.04 1500 5.80 13.33 17.72 94630 1.31 13.33 5.40 160D 6.54 15.02 18.90 100939 1.48 15.02 5.76 1700 7.31 16.81 20.08 107247 1.65 16.81 6.12 1800 8.13 1 1&68 1 21.26 1 113556 1 1.84 1 18.68 6.48 U.S Q5tcnary units in this docurrnent are the standard;the rratric units are provided for reference oily.the\dues stated in each system are riot ood equ\d ents. ® NIBMlNCWCRDFEADQ14RL9s• 1516MICD-l33LWST.• BJ04WT,IN46516-1740• LISA- RA1.80D.234.0227 • TKHSERAC1BRt 1.888.446.4226• FAX 1.800.234.0557• INTB:?VA-nCNALSERACER-t+1.574.2951.3221• FAX+1.574.295.3455 vwvw.riboo.com NIBCCY www.nibco.com AHEAD OF • TYPE" OOP PER E-WATER FLOW AND FRICTI ON h PER 100FEET MarammQD. = 8.1270inches(206.4258rrm) NorrinalQD. = &1240imhes(206.3496rrm) MirrrrumQD. = &1210imhes(206.2734rrm) Narird I.D. = 7.5820inctm(1925828mn) Norrird Wail Thidvrem = 0.2710irdies(6.8834rrm) Raw Area = 45.1500sq.irxfffi(29128.959q.rrm) Hamm W llians Forrr la CFador = 150 FLAN,Q Ressure Lass Head Loss Mdocity RDeV,Q Ressure Loss Fwd Lass Mdocity (am) (psi/100ft) (ft/100ft) (ftJser-) (cu.arVsea) 04ai100m) (m100m) (rd ) 2DD 0.04 0.09 1.42 12517 0.01 0.09 0.43 400 0.15 0.34 284 25236 0.03 0.34 0.87 600 0.31 0.71 4.25 37852 0.07 0.71 1.30 800 0.53 1.21 5.68 50469 0.12 1.21 1.73 1000 0.80 1.83 7.11 63087 0.18 1.83 217 1200 1.11 256 8.53 75704 0.25 256 2.60 1400 1.48 3.41 9.95 88321 0.34 3.41 3.03 1600 1.90 4.36 11.37 100939 0.43 4.36 3.47 1800 236 5.43 1279 113556 0.53 543 3.90 2000 287 6.60 14.21 126173 0.65 6.60 4.33 22DO 3.42 7.87 15.63 138791 0.77 7.87 4.76 2400 4.02 9.24 17.05 151408 0.91 9.24 5.20 2600 4.67 10.72 1&48 164025 1.06 10.72 5.63 2800 5.35 1229 19.90 176643 1.21 1229 6.06 3000 6.08 13.96 21.32 188260 1.38 13.96 6.50 3200 6.85 15.73 2274 201877 1.55 15.73 6.93 3400 7.67 17.60 24.16 214495 1.73 17.60 7.36 3600 8,53 19.57 25.58 227112 1.93 19.57 7.80 3800 9.42 21.62 27.00 239729 213 21.62 8.23 4000 1 10.36 1 23.78 1 28.42 1 252347 1 234 23.78 1 8.66 8"TYPE"L" OOPPE TUBE-WATER FLOW AND FRICTICN LC6S PER 100 FEET MaranunOD. = &1270indres(2D6.4258mn) NorrinalQD. = 8.1240irches(206.3496rrm) MininumOD. = 8.1210indres(206.2734rrm) Noninall.D. = 7.7240inches(196.1896nm) NorrinaMbIl Tttidmess = 0.2000 imhes(5.080 rr m) Raw Area = 46.8570 sq.irx ies(30230.26 sq.rrrn) HawWlliarrsFarmAa CFador = 150 FLON,Q Ressure Lass Head Lass \kiocity FLO,N,Q %ssure Loss Fad Lass \klocity (GRVI) (psi/100ft) (ft/100ft) (ftJsec.) (cu.cm'sec) "loom) (0100m) (m'seo.) 200 0.04 0.09 1.37 12617 0.01 0.09 0.42 400 0.13 0.31 274 25235 0.03 0.31 0.83 600 0.28 0.65 4.11 37852 0.06 0.65 1.25 80D 0.48 1.11 5.48 50469 0.11 1.11 1.67 1000 0.73 1.67 6.85 63067 0.16 1.67 209 1200 1.02 234 &22 75704 0.23 234 250 1400 1.35 3.12 9.59 88321 0.31 3.12 2.92 1600 1.73 3.99 10.96 100939 0.39 3.99 3.34 1800 216 4.96 1232 113556 0.49 4.96 3.76 2000 262 6.03 13.69 126173 0.59 6.03 4.17 2200 3.13 7.19 15.06 138791 0.71 7.19 4.59 2400 3.68 &44 16.43 151408 0.83 &44 5.01 2600 4.26 9.79 17.80 164025 0.96 9.79 5.43 2800 4.89 11.23 19.17 176543 1.11 11.23 5.84 3000 5.56 1276 20.54 189260 1.26 1276 6.26 3200 6.26 14.38 21.91 201877 1.42 14.38 6.68 3400 7.01 16.08 23.28 214495 1.58 16.08 7.10 3600 7.79 1788 24.65 227112 1.76 17.88 7.51 3800 8,61 19.76 2&02 239729 1.95 19.76 7.93 4000 1 9.47 1 21.72 1 27.39 1 252347 1 214 21.72 1 8.36 U.S custorroy units in this doa rnent are the standard;the metric units are provided for reference only The values stated in each system are not exact equivalents NIBDJ INC WCR D FEADCLART9T• 1516 MIOM83J 2r'ST• BJ44gU IN 465164740• LJS4• R-t 1.800.234.0227 m T67-I SERACES PH 1.888.446.4226• FAX 1.800.234.0557• IN1T33VAl1QVALSERACE R-t+1.574.295.3221• FAX-+1.574295.3455 www.riiboo.00m www.nibco.com AHEAD OF • ■ •••• C E-WATER FLOW AND ON A PER 100FEET MawanunQD. = 8.1270indies(206.4258rrm) NorrinalQD = 8.1240inches(2o6.3496rrm) MininmQD = 8.1210imhes(206.2734mn) NorrirEd I.D. = 7.7840imhes(197.7136rrm) NomreIVVJIThidvless = 0.1709ind-es(4.3180rrm) RaaArea = 47.5878sq.indies(3(J701.74sq.rrm) HamnV\AIIiarrsFcm-ula CRdor = 150 RDN,Q Ressire Loss H3ad Loss malocity RD/V,Q Ressure Loss Fbad Loss Mdocity (GM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.arysec) 04:bv100m) (m100m) (m'seo.) 200 0.04 0.08 1.35 12617 0.01 0.08 0.41 400 0.13 0.30 270 25215 0.03 0.30 0.82 600 0.27 0.63 4.05 37852 0.06 0.63 123 800 0.46 1.07 5.39 50469 0.10 1.07 1.64 1000 0.70 1.61 6.74 63087 0.16 1.61 205 120D 0.98 226 8.09 75704 0.22 226 247 1400 1.30 3.00 9.44 88321 0.30 3.00 288 1600 1.67 3.84 10.79 100939 0.38 3.84 3.29 1800 208 4.78 12.14 113556 0.47 4.78 3.70 2000 253 5.80 13.48 126173 0.57 5.80 4.11 2200 3.01 6.92 14.83 136791 0.68 6.92 4.52 2400 3.54 8.13 16.18 151408 0.80 8.13 4.93 29DD 4.11 9.43 17.53 164025 0.93 9.43 5.34 2800 4.71 10.81 18.86 176643 1.07 10.81 5.75 300D 535 1229 20.23 189290 1.21 1229 6.16 32DD 6.03 13.85 21.57 201877 1.36 1385 6.58 340D 6.75 15.49 2292 214495 1.53 15.49 6.99 3600 7.50 17.22 24.27 227112 1.70 17.22 7.40 3800 8.29 19.03 25.62 239729 1.88 19.03 7.81 4000 9.12 20.92 1 26.97 1 252347 1 2.06 1 20.92 1 8.22 1 ••■■ER TUBE-WATER FLOW AND •N LOSS PER 100FEEF MarammQD = 10.1270inches(257.2258mn) NoninalQD. = 10.1230indies(257.1242mn) MinimmQD = 10.1190indies(257.0226mn) Noninall.D. = 9.4470imhes(239.9538mn) Norri nal WeJ I Thidoess = 0.3380 i mhes(8.5852 mn) Row Area = 70.0935 sq.i nd-m(4921.52 sq.mn) Ha2enV\AlliarrsForrrula CRdor = 150 RDN,Q Ressrre Loss Head Loss \kiodty RON,Q Pressure Loss Head Lass Meiocity (GM) (psi/100ft) (ft/100ft) (ft./sec.) (cu.aTYsec.) "loom) (010Dm) (cosec) 200 0.01 0.03 0.92 12617 0.00 0.03 0.28 400 0.05 0.12 1.83 25235 0.01 0.12 0.56 600 0.11 0.24 275 37852 0.9 0.24 0.84 800 0.18 0.42 3.66 50469 0.04 0.42 1.12 1000 027 0.63 4.58 63087 0.06 0.63 1.40 1200 0.38 0.88 5.49 75704 0.09 0.88 1.67 1400 0.51 1.17 6.41 88321 0.12 1.17 1.95 1600 0.65 1.50 7.32 100939 0.15 1.50 223 1800 0.81 1.86 8.24 113556 0.18 1.86 251 2000 0.98 225 9.15 126173 0.22 226 279 2200 1.17 270 10.07 138791 0.27 270 3.07 240D 1.38 317 10.99 151408 0.31 3.17 3.35 2600 1.60 3.68 11.90 164025 0.36 368 3.63 28DD 1.84 4.22 1282 176543 0.42 4.22 391 3000 209 4.79 13.73 1892660 0.47 4.79 4.19 3200 235 5.40 14.65 201877 0.53 5.40 4.46 3400 263 6.04 15.56 214495 0.60 6.04 4.74 3600 292 6.71 16.48 227112 0.66 6.71 5.9 3800 323 7.42 17.39 239729 0.73 7.42 5.30 4000 355 8.16 18.31 252347 0.80 8.16 5.58 420D 389 8.93 19.22 254964 0.88 8.93 5.86 4400 1 4.24 1 9.73 1 20.14 1 277581 1 0.96 1 9.73 1 6.14 U.Scustcn-ary units i n ths document are the sta-dxd;the me-tric units are provided for reference only the\d Lies stated in each system are riot ood equval ents. SI NIBMINCWCRDFEADQ14Rf9s• 1516MICD_B3LWST.• BJ04WT,IN46516-1740• LISA- RA1.8013.234.0717 TEH SERACTB Rt 1.888.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com NIBCCY www.nibco.com AHEAD OF • 1 •N'ER TUBE-WATER FLOW AND ON •► 100FEET Ma do mQD. = 10.1270 indies(257.2258 rrm) NarireI QD. = 10.1230 imhes(257.1242 rrm) MirimrnQD = 10.1190imhes(257.0226mn) Narind l.D. = 9.6230irde (244.4242mn) Norrird Wall l dvies = 0.2500 indies(6.3500 mn) RoN Area = 727295 sq.irdffi(4692219 sq.mn) HamnWlliansFormla CRdor = 150 FLAN,Q Ressure Loss Head Loss Mblodty RO,N,Q Ressure Lass Hid Lass Mblocity (am) (psi/10Dft) (Ft/100ft) (ftJsea) (cu.adsea) odai10Dm) (0100m) (cosec) 20D 0.01 0.03 0.88 12517.33 0.00 0.03 0.27 400 0.05 0.11 1.76 25234.67 0.01 0.11 0.54 60D 0.10 0.22 265 37852.00 0.02 0.22 0.81 800 0.16 0.38 3.53 50469.33 0.04 0.38 1.08 1000 0.25 0.57 4.41 63D86.67 0.06 Q57 1.34 1200 0.35 0.8D 5.29 75704.00 0.08 0.80 1.61 1400 0.46 1.07 6.18 88321.33 0.11 1.07 1.88 1600 0.60 1.37 7.06 100938.67 0.13 1.37 215 1800 0.74 1.70 7.94 113556.00 0.17 1.70 242 2000 0.90 207 8.82 126173.33 0.20 207 2.69 22D0 1.07 247 9.70 138790.67 024 247 296 2400 1.26 290 10.59 151401100 0.29 290 3.23 2600 1.46 3.36 11.47 164025.33 0.33 3.36 3.50 2800 1.68 3.85 1235 17664267 0.38 3.85 3.76 3000 1.91 4.38 13.23 189280.00 0.43 4.38 4.03 3200 215 4.93 14.12 201877.33 0.49 4.93 4.30 3400 240 5.52 15.00 214494.67 0.54 5.52 4.57 3600 267 6.13 15.88 22711200 0.60 6.13 4.84 3800 295 6.78 16.76 239729.33 0.67 6.78 5.11 4000 3.25 7.45 17.65 252346.67 0.73 7.45 5.38 4200 3.56 &16 18.53 264964.00 0.80 8.16 5.65 4400 3.88 &89 1 19.41 1 277581.33 1 0.88 1 &89 5.92 10"TYPE"M" COPPER TUBE-WATER FLOW AND FRICTI ON LOSS PER 100 FEET MaprrumOD. = 10.1270indies(257.2258mn) NorrinaMD = 10.1230ir&os(257.1242mn) MlninumOD. = 10.1190irdies(257.0226mn) Norrimill.D. = 9.6990indres(247.3546mn) Norrird Wail Thidoess = 0.2120imhes(5.3848rrm) Ravv Area = 73.8829sq.indies(47666.28sq.mn) HamnWlliansFomula CFador = 150 FLO.N,Q Resre Lm Head Loss Wocity FLON,Q Ressre Lass Head Lass Mdocity (CAM) 0/100ft) (ft/100ft) (ftJsec.) (ai.adsea) 04wi00m) (m100m) (cosec.) 200 0.01 0.03 0.87 12617 0.00 0.03 0.25 400 0.04 0.10 1.74 25735 0.01 0.10 0.53 600 0.09 0.21 261 37852 0.02 0.21 0.79 800 0.16 0.37 3.47 50469 0.04 0.37 1.06 1000 0.24 0.55 4.34 63087 0.05 0.55 1.32 1200 0.34 0.77 5.21 75704 0.08 0.77 1.59 1400 0.45 1.03 6.08 88321 0.10 1.03 1.85 1600 0.57 1.32 6.95 100939 0.13 1.32 212 1800 0.71 1.64 7.82 113556 0.16 1.64 238 2D00 0.87 1.99 8.68 126173 0.20 1.99 265 2200 1.03 237 9.55 138791 0.23 237 291 2400 1.21 279 10.42 151408 0.27 279 3.18 2600 1.41 3.23 11.29 164025 0.32 3.23 3.44 2800 1.62 371 1216 176643 0.37 3.71 3.71 3000 1.84 4.21 13.03 189260 0.42 4.21 3.97 3200 207 4.75 13.90 2771877 0.47 4.75 424 3400 231 5.31 14.76 214495 0.52 5.31 4.50 3600 257 5.90 15.63 227112 0.58 590 4.76 3800 284 6.53 16.50 239729 0.64 6.53 5.03 4000 3.13 7.17 17.37 252347 0.71 7.17 5.29 4200 3.42 7.85 1&24 264964 0.77 7.85 5.56 4400 1 3.73 1 &56 1 19.11 1 277581 1 0.84 1 &56 5.82 U.S a istanary trots in this doa rrent are the standard;the rretri c snits are provided for reference Orly.The vd ues stated in each system are not exact ec}u\rdenta NIBDJ INC WCR D FEADCLART9T• 1516 MIOM83J 2i'ST• BJ44gU IN 465164740• L1S4• R-t 1.800.234.0227 m TT37-I SERACES PH 1.888.446.4226• FAX 1.800.234.0557• IN1T334Al1QVALSBZv10E R-t+1.574.295.3221• FAX.+1.574.295.3455 • vwvw.riboo.00m www.nibco.com AHEAD OF • OOP PER E-WATER FLOW AND FRICTI ON •► PER 11 mcwff nQD. = 121270indies(308.0258rrm) NornrdOD. = 12.1230imhes(307.9242rrm) MininmQD = 12.1190irdies(307.8226mn) Nonird l.D. = 11.3130indies(287.3502nTn) mr�al NoVVJI-hclrless = 0.4050ind-es(10.2870rrm) Row Area = 100.5184sq.irxies(64850.43sq.nn) FtamnV\AIIiarrsFomula CRdor = 150 FLON,Q Ressure Loss F3ad Loss malocity RD/V,Q Ressure Loss H3erl Loss Mblocity (Gl:m) (psi/1o0ft) (ft/10oft) (ft./sec.) (cu.an'sec) 04:bv100m) (m100m) (m'sea) 1000 0.11 0.26 3.19 63087 0.03 0.26 0.97 1200 0.16 0.37 3.83 75704 0.04 0.37 1.17 1400 0.21 0.49 4.47 88321 0.05 0.49 1.36 1600 027 0.62 5.11 100939 0.06 0.62 1.56 1800 0.34 0.77 5.75 113556 0.08 0.77 1.75 2000 0.41 0.94 6.38 126173 0.09 0.94 1.95 2200 0.49 1.12 7.02 138791 0.11 1.12 214 240D 0.57 1.32 7.66 151408 0.13 1.32 233 2600 0.67 1.53 8.30 164025 0.15 1.53 253 2800 0.76 1.75 &94 176643 0.17 1.75 272 3000 0.87 1.99 9.58 189260 020 1.99 292 3200 0.98 225 10.21 201877 0.22 225 all 340D 1.09 251 10.85 214495 0.25 251 3.31 3600 1.22 279 11.49 227112 0.28 279 3.50 380D 1.34 3.09 1213 239729 0.30 3.09 3.70 400D 1.48 3.39 12.77 252347 0.33 3.39 3.89 42DD 1.62 3.71 13.41 254964 0.37 3.71 4.09 4400 1.76 4.05 14.04 277581 0.40 4.05 4.28 4600 1.92 4.39 14.68 290199 0.43 4.39 4.48 4800 207 4.75 15.32 302816 0.47 4.75 4.67 5000 224 5.13 15.96 315433 0.51 5.13 4.86 5200 240 5.51 16.60 328051 0.54 5.51 S06 5400 258 5.91 17.24 340668 0.58 5.91 5.25 5600 276 6.32 17.87 353285 0.62 6.32 5.45 5800 294 6.75 18.51 365908 0.67 6.75 5.64 6000 3.13 7.18 19.15 378520 0.71 7.18 5.84 6200 3.33 1 7.63 1 19.79 1 391137 1 0.75 1 7.63 6.03 12"TYPE"L" CICIPPER TUBE-WATER FLCIW AND FRICTION LOSS PER 100 FEET MadnMOD. = 12.1270indies(30&0258rrm) NcMrdQD = 12.1230imhes(3CY7.9242rrm) MirimmQQ = 12.1190indies(307.8226rrm) Nomrd I.D. = 11.5630imhes(293.7002rrm) Ncrdrd Wall Thidiness = 0.280Dimhes(7.1120rrm) RavArea = 105.0101sq.indes(67748.29sq.rrm) FtamnV\AIliarrsFcrmala CFador = 150 RDN,Q Rnssr re Loss Fwd Loss malocity RDN,Q Ressrue Loss H3acl Loss Mdocity (CFM) (pd/1Wft) (ft/100ft) (ft./sec.) (cu.crn'sec) Wdloom) (0100m) (m'sea) 1000 0.10 0.23 3.06 63087 0.02 023 0.93 1200 0.14 0.33 3.67 75704 0.03 0.33 1.12 1400 0.19 0.44 4.28 88321 0.04 0.44 1.30 1600 0.24 0.56 4.89 100939 0.06 0.56 1.49 1800 0.30 0.70 5.50 113556 0.07 0.70 1.68 290D 0.37 0.85 all 126173 0.08 0.85 1.86 ZMD 0.44 1.01 6.72 138791 0.10 1.01 205 2400 0.52 1.19 7.33 151406 0.12 1.19 223 2500 0.60 1.37 7.94 164025 0.14 1.37 242 2800 0.69 1.58 &55 176643 0.16 1.58 261 3000 0.78 1.79 9.17 189250 0.18 1.79 279 3200 0.88 202 9.78 201871 0.20 202 298 3400 0.98 225 10.39 214495 0.22 226 3.17 3600 1.09 251 11.00 227112 0.25 251 3.35 3800 1.21 277 11.61 239729 0.27 277 3.54 4000 1.33 3.05 1222 252347 0.30 3.05 3.72 4200 1.46 3.34 1283 2549964 0.33 3.34 3.91 4400 1.59 3.64 13.44 277581 0.36 3.64 4.10 4600 1.72 3.95 14.05 290199 0.39 3.95 4.28 4800 1.86 4.27 14.67 302816 0.42 4.27 4.47 5000 201 4.61 15.28 315433 0.45 4.61 4.66 5200 216 4.96 15.89 328051 0.49 4.96 4.84 5400 232 5.31 16.50 340668 0.52 5.31 5.03 5600 248 5.68 17.11 353285 0.56 5.68 5.21 5800 265 6.07 17.72 365903 0.60 6.07 E40 6000 282 6.46 18.33 378520 0.64 6.46 5.59 6200 1 299 1 6.86 1 1&94 1 391137 1 0.68 1 6.86 1 5.77 U.S.c stcrrary units in this down-at are the standard;the rradc units are pravi ded for referenoe only.The values stated in each systemare not exact equivalents. NIBMlNCWCRDFEADCLARTBS• 1516MICOLB3LWSL• BJ04WT,IN46516-1740• LISA- 1341.801).234.0227 • TITH SERAC1B Rt 1.888.446.4226• FAX 1.830.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com MIBCCY www.nibco.com AHEAD OF • TYPE" COPPER TUBE-WATER FL• ON •► PER 100FEET Ma do mQD. = 121270 ind-es(308.0258 rrm) Nominal QD. = 121230 imhes(307.9242 rrm) MinirrumQD. = 121190imhes(307.8226rrm) Nornrol I.D. = 11.6150indies(295.021 rrm) Norrird Wall Thidv.1ess = 0.2540 indies(6.4516 rrm) Flow Area = 105.9567 sq.indres(68358.01 sq.rrm) HamnWlliarrsFbrmla CRdor = 150 FLAN,Q Ressure Loss I-fyad Loss Mblodty FLON,Q Ressure Loss Haad Lass Mblocity (am) (psi/100ft) (ft/100ft) (ftJsec) (cu.crrYsea) 04ai100m) (0100m) (cosec) 1000 0.10 0.23 3.03 63087 0.02 0.23 0.92 1200 0.14 0.32 3.63 75704 0.03 0.32 1.11 1400 0.19 0.43 4.24 88321 0.04 0.43 1.29 1600 0.24 0.55 4.84 100939 0.05 0.55 1.48 1800 0.30 0.68 5.45 113556 0.07 0.68 1.66 2000 0.36 0.83 6.06 126173 0.08 0.83 1.85 2200 0.43 0.99 6.66 138791 0.10 0.99 2.03 2400 0.51 1.16 7.27 151408 0.11 1.16 222 2600 0.59 1.35 7.87 164025 0.13 1.35 240 2800 0.67 1.54 8.48 176643 0.15 1.54 2.58 3000 0.76 1.75 9.08 189290 0.17 1.75 277 3200 0.86 1.98 9.69 201877 0.19 1.98 295 3400 0.96 221 10.30 214495 0.22 221 3.14 3600 1.07 246 10.90 227112 0.24 246 3.32 3800 1.18 271 11.51 239729 0.27 271 3.51 4000 1.30 298 1211 252347 0.29 298 3.69 4200 1.42 3.27 1272 254964 0.32 3.27 3.88 4400 1.55 3.56 13.32 277581 0.35 3.56 4.06 4600 1.68 3.87 13.93 290199 0.38 3.87 4.25 4800 1.82 4.18 14.53 302816 0.41 4.18 4.43 5000 1.97 4.51 15.14 315433 0.44 4.51 4.61 5200 211 4.85 15.75 328051 0.48 4.85 4.80 5400 227 EX 16.35 340668 0.51 5.20 4.98 5600 243 5.56 16.96 353285 0.55 5.56 5.17 5800 259 5.93 17.56 365903 0.59 593 5.35 6000 276 6.32 18.17 378520 0.62 65,32 5.54 6200 293 R71 1 1&77 1 391137 1 0.66 6.71 1 5.72 U.S adorrery u its in this does meet are the standard;the rretricu its are presided for referffmonly.The_\du s stated in each systemare not exad equvalerrts. NIBMINC Vk a EADCL14Rf@S• 1516MIDDL®LR(ST• BJQ*Rt;IN46516.4740• USA,- R-t 1.800.234.0227 TECH SBRACES PH 1.888.446.4226• FAX 1.800.234.0557• IN193VAl1QVALSERACE R-t+1.574.295.3221• FAX-+1.574295.3455 • www.riiboo.com www.nibco.com AHEAD OF • CqW Water Tubecontinued COPPER TUBE-TYPES,STANDARDS,APPLICATIONS,TEf\4PERS AND LENGTHS Oxmrercially Available Lengths Tube Type CblorODde Standard Application Noninalor Standard 92es Drawn Aided Type Green ASTM B88 Domestic WaterSsnAoeDstri bution Straight Lengths: 1/4-inchto8-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Rotection 10-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar 12-inch 12 ft.(3.7m) 12 ft.(3.7m) Rd/Rd Cll Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) I-IM/AC — 100 ft.(30.5m) Snow Melting 11/4-inch&11/2--irxh — 60 ft.(18.3m) 2-i rich — 40 ft.(12.2m) — 45 ft.(13.7m) Type Bue ASTM B88 Domestic Water Service DistribUion Straight Lengths: 1/4-inchto10•inch 20 ft.(6.1m) 20 ft.(6.1m) FireFrotedion 12-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar Fuel/Find Cll Natural Gas Coils: 1/4-inchto1-inch — 60 ft.(18.3m) LiquifiedFttrdeum(U�Cas — 100 ft.(30.5m) WAC 11/4-inch&11/2--inch — 60 ft.(18.3m) Snow Melting 2-i rich — 40 ft.(12.2m) — 45 ft.(13.7m) Type Fbd ASTM B88 DomesticWater Service DistribUion Straight Lengths 1/4-inchto12-inch 20 ft.(6.1m) NA Fire Rotedion Solar Find/Rd 01 H,/AC Snow Melting DJW Yellow ASTM B306 Drain Straight Lengths: 11/4-inch to8-irich 20 ft.(6.1m) N/A Waste Vert H\/AC Solar ACR Bue ASTM B280 Air Oonditi cni ng Straight Lengths: 1/4-inch to 41/8-inch 20 ft.(6.1m) 20 ft.(6.1 my Fbfrigeration Natural Cris Coils: 1/8-inchtoV/Anch — 50 ft.(15.3m)' Liquified Ft trdeum(L)Gas CKY Type ASTM 8819 Medical Gas Straight lengths 1/4-i rich to8-irich 20 ft.(6.1m) N/A M® Green CKY/M® CKY/ACR Type L ACRM® Bue Type Yellow ASTM B837 Natural Gas Straight Lengths: 3/A rich to 11/8-inch 12 ft.(3.7m) 12 ft.(3.7m)' Liquified Fbtrdeum(LF)G3s 20 ft.(6.1m) 20 ft.(6.1 my Coils: 3/84 rich to 7/8-inch — 60 ft.(18.3m)' — 100 ft.(30.5mp Available asspedal order only US c stcmary units in this doaznert are the standard;the metric uits are prodded for refereroe only The\d Lies stated in each system are not exact egl.ivalents NIB0DINC WCRDHE DaJ4Rfff5. 1516MIDDL®J;YST.• BI4 ARr,IN46516-4740• USA• R-t 1.800.234.0227 TB37 l SERACt$Rt 1.888.446.4226• FAX 1.800.234.0557• INTB3JATICNAL SERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboaoom NIBCCY www.nibco.com AHEAD OF • of Sd Cbi When adj oi ni rig surfaces of copper and copper al I oys meet under proper conditions of d earliness and temperature, solder wi I I make a perfect adhesion.The strength of joint is equal to or even greater than the strength of tube done. -Surfaoe tensi on seal s t he j a nt.Capi I I ary attraction draws solder into,around,and al I about the j oi nt.It's easy to learn to n-eke a perfect sdderjant when you use NIBODFittings. WITH 95-5 SOLDERAND INTERMEDIATELY OORFZOSIVE FLUX 1. Cut tube end square,ream,bum and size. 2. Use sand cloth or steel wire brush to dean tube and cup to a bright metal finish. r'- • 3. Apply solder fluxto outside of tube and inside of cup 4. Applyflan-etothefittingto heat tube and solder cup offitting off itti rig carefully so that surfaces tobeja red are con-0etely until solder melts when placed atjantof tube and fitting. covered.Use flux spari ngl y. 5. Fbmnve fl acre and feed sot der i nto t he j ci nt at one or 6. Fb-nove excess solder with a small I brush or wiping cloth whi I e two poi nt s unt i I a ri ng of sol der appears at t he end of t he f i tt i ng. the solder is plastic. The correct amount of solder is appromn-kely equal to 11/2 the diameter of thefitting... 3/4'(20mm)solder for 1/2'fitting,etc. NIBDJINC:WCR D FEADC LAR19Z5. 1516 MIDaEBLW ST.• BXFAW IN 46516-4740• LISq• R-t 1.800.234.0227 Tffii S9RACES R-t 1.888.446.4226• FAY 1.800.234.055!• INTB:NA-1C NAL S9RACE R-t+1.574.295.3221• FAY+1.574.295.3455 www.niboaoom www.nibco.com AHEAD OF • 7he IiMM (I RC9 ■ Best results wi I I be obtai red by a skilled operator errpl oyi rig the step-by-step brazing technique that fol lows: 1. the tube should be curt to desired length with a square cut, result in an unsatisfactoryjant.Braa rig aIoyswiII riot flow a"or preferably in a square-end sawi rig vise.The artti ng wheel of the bond to oxd des-,and oi I y or greasy surfaces tend to repel fl uxes, type specif ically designed for cutting copper tube wil I alsodoa leaving bare spots which wilI oxidize,resulting in voids and satisfactoryjob.The tube should be the exact lerghneeded,sothat i rid usions. thetubewill enterthecupofthefittingall thewaytotheshoulder of the cup.Fbrrove a1I slivers and burrs left from cutting the tube,by 5. R ux should be appl i ed to ream rig and f i I i ng,both i nsi de and outsi de. the tube and solder lap spasnglyand in afaidy 2. To make a proper branngjant,thedearance between thesol der thin cordstency.Avoid " cup and the tube should be apprcx i n-Ad y 0.001"to 0.010" f I ux on areas not d eared. (0.0254rmto0.254rrrn).Maintairunga good fiton parts tobe Part iculadyavoidgetting brazed i nsures: excess fl ux i nto the i nsi de Easeof Application—Excessively wide tolerances tend to break ofthetubeitself.Fiuxhas capillaryforoe;and,asa result the alloywill eitherfail toflow threeprirxipal functions throughout thejant or mayflush out of thejant. to perform Cblrosion Fbsistanoe—There is also a direct relation between the A It prevents the oxidation of the metal surfaces during the heati rig oomosionresi stance ofajant and thedearance between raTbers. operation byexdudingoxygen. Eoononry—If bran ng al toys are to be used ecorn-ical Iy,they,of B. It absorbs and dissol ves resi dual oxides that are on the surface neoessity,mast be appl i ed i n thej a nt proper and i n mi ni mum and t hose ox i des whi ch may form dud ng the heat i ng operati on. quantiti es,usingme-dy enough aIoytofiIIthe area between the G It assi st s i n t he fl ow of t he al I oy by present i ng a d ean nascent rnen-bers. surface for then-eltedalIoytofIo✓v over.In addition,it is an excel lent temperature i ndi cat or,espedalIy if an i ndi cat irig flux is 3. The surfaces to be j oi red must be d ean and free from a 1, used. grease and heavy oxides.The end of the tube need be cleared cnl yfor a di stance 6. Imradiately after fl uxi ng,the parts to be brazed should be slightly mare than it is to assenbed.If fl uxed parts are al l owed to stand,the water i n enter the cup.-Wal thefluxwill wire brulsi-es evaporate,and designed to dean dried flux is l iable to ' tube ends may be I flake off,exposi ng used,but they should4 therrTetal surfaces be carefully used so to oxidation from - that an excessive amrount the heat.Assenbe of inetal will not be thejant byinserting rerrmed fromthe tube.Finesanddothoremarydoth thetubeintothe may also be used with the same precautions.The cleaning should cup,hard agai nst I riot be done with steel wool,because of the 1 i kel i hood of I eavi ng the stop.The small sl ivers of the steel or a I i n thejoi nt. assen-bly should be fi mriy supported so that it will rerrei n in al ignmarrt dud ng the brazing operation. 4. The cup of the fitting should be d eared by rrethods si mi I ar -- tothose used for the tube end,and care shoul d be --- observed in removing yI red dues of the d eani ng midi um Attempti ng to braze a contemi mated or an i mpropedy deaned surface wi 111 NIB00ING WC}aDFFADCLART9'S• 1516MIDDLBBLR(ST.• RA-PRr,IN46516-4740• USA- R-t 1.800.234.0227 • TT37-ISEF\MCFSR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAx+1.574.205.3455 www.niboaoomm NIBCCY www.nibco.com AHEAD OF • 7. D-aa rig is started byapplyi rig heat tothe parts tobeja red.The NOTE Fortubi rig one i rich and Iarger,itis preferred rret hod isbytheoxyaoetylenefIame.Ropane and other diff i cull ttobri ngthewhoiejointuptoheat gases are sometimas used onsm alIersizes.AcightIyredudng at one ti me.It frequertly wi I I be found fl arre shout d be used,wi th a sl i ght feat her on t he i nner bl ue cone; desi rabl e to use a doubl e-ti p torch to the outer portionof the flame,pal e green.Hyat the tubefirst, n-dntain the proper temperature over the begi nni ng at about one i rich from the edge of the fitti ng.SAteep the larger area.ArriIdpre-heating of the fl arres around the tube i n 9-ort strokes up and down at right angles whole fitti ng i s recom met ded.The to the run of the tube.It i s very i rrportant that the flame be i n heati ng then can proceed as i n steps 7,8, conti rx la is motion and shoul d not be al l owed to rerrai n on any one 9,and 10.if diffi cul ty i s encountered in point toavoidbuming through the tube.Generally thefluxn-aybe getting thewhoiejantuptoheatatone used asaguideasto how longtoheatthetube,continuing heating time,then when thejointisneariyupto after the fIux starts to bubble orwork,and until thefluxbecomes thedesiredtemperaturethealIoyis quiet andtransparent,Iikedearwater.ThefluxwiIIpassthrough concentrated inaIinitedarea.Atthe four stages: bras ng temperature the al Icy is fed i nto A At21ZF(100 Qthewaterbalsoff. thejant and the torch is then moved toan D At 600°F(315.6°C)the f ux becomes white and sl i ghtl y puffy and adj area and he operat i on carri ed starts towork on progressively all around thejoi nt. C; At 800°F(426.T G)it I ays agai rest the surface and has a mi I ky HCRZCNTAL JC7 NTS—When rr eh ng appearance. hoI joi nts,it i s preferable to D. At 1100°F(593.3°G)it iscorrpletelyd ear and active and has the start applYi J the braangal Icy at the ! appearance of water. 5 d d ock positi on,then move around to the 7 ddodk position and then 8. Now switch the fIamto the fitti ngatthe rrue up the sides to the top of the base of the cup.Heat unifomiy, joi nt,maN rig sure that the sweepi ng the fl arre from the operati ons overlap. fitti ng to the tube until the fl ux on the fitting becomes quiet. �11CALJCINTS—a vertid Avoid excess ve heat irig joints,itisin- aterialwherethe of cast fittings. start is made.If the opening of the cup is panted down,care should be taken to avoid oved-ieati ng the 9. When the flux appears liquid tube,as this may cause theal Icy to run clown the tube.If this condition and transparent on both the is encountered,take the heat away and al low the-al I cy to set.Then tube and the fitting,start sweeping reheat the solder cup of the fitting to draw up the alloy. the flarre back and forth along the axis of thejoint to maintain heat on the parts to beja ned,especially toward the base of the cup of After the bras ng alloy has set, thefitting.T heflarremustbekeptmavingto avoid burning the tube remove redclual fluxfromthejoint k5 or the fitti ng. area as it is corrosive and presents an and can appearance and } 10.Apply the brazing wire or rod at a pa nt condition.Hit water or steam and a ' where the tube enters the socket of the soft dot h shoul d be used.Wrot fitting.Theterrperatureof the jant fitti rigs may bechil led;however itis kr � should be hot enough tomdtthe acMsabletoal low cast fitti ngsto braangallcy.Keeptheflarreaway f cool nat ural I y to some extent before from the rod or wi re as i t i s fed I apply ng a swab.Al l fl ux mast be renuved before i nspedi on and intothejant.K epboththe pressuretesting. fitti ng and the tube hued by m ov ng the flame back and forth from one to the other as the al lay is drawn i nto the joi nt.When the proper TFCLJBLESFOTS temperature i s readied,the al Icy wi I I flaw readi ly i nto the space If the alloyfailstofl between the tube ater wal I and the f itti ng socket,drawn i n by the av orhasaterxlelxytoballup,itindicates natural force of capi I lary attraction.When the jant isfiIIed,a o)adationon the metal surfaces,orinsuffident heat on the parts to continua.rsfillet ofbraangalloywillbevisiblecorrpletelyaround bejaned.If work starts too)adiza duri rig heating,itindicatestoo thejant.Stop feeding as soon asthejdntisfilled,usingtableon littlefILK orafluxoftoothinoonsistencylf the braangalloy page 54 as a guide for the al I oy consumption. refuses to enter theja nt and tends to fl ow over the outside of either mealier of theja nt,it indicates this member is overheated,or the other is underheated,or both.In both cases,operations should be stopped and the jantsdisassenbed,recleaned and fluxed. NIBDJ INC:WCR D FEADC1a4Rr9ZS• 1516 MIDaEBLW ST.• 9-W-AW IN 46516-4740• USA• R t 1.800.234.0227 m TH7iSERACESR-t 1.888.446.4226• FAY 1.800.234.055!• INTB:NA-flCNALS9RACER-t+1.574.295.3221• FAX+1.574.295.3455 www.niboaoom www.nibco.com AHEAD OF • PdW N FE) TLUbi SYSTEM RTTING >R •R Mab ng a Gonnedi on 1. Using a tube cutter,out tubing squarely and remove burrs. 2. Side copper cri ap ring on t ubi ng. 3. Insert ribbed fitting into tubing until tubi rig contacts the fitti rig shoulder 4. Center the crirr ping tool jaws exactly over the ring while maintaining its (tube stop).Position the cri rrp ring on the tubing so position relative to the fitting.CH rrp the ri rig by dosing the handles that the edge of the ring is 1/8"to 1/4'(3 to 6rrm)fromthe together to the positive stop on the tool.O-eck the after-cringed end of the tube. diameter of each ring with the crimp gauge.If the small flats on the gauge do riot fit over the criaped ring,the ri ng is under-criaped.Cutout any under-cri need ri ngs and fitti rigs and corrpl etel y repl aoe.DO NOT f€CRMP 1/;34 .NIBODreomm-erids the use of oopper ai rrp n rgs ONLYand a properly calibrated full cirde crirrpi ng tool forja ni ng FEXtubi rig and copper barbed fitti rigs. NIBOJING WC DHEN)C.WRT9'S• 1516MIDDL®lR'ST.• RA-PRr,IN46516-4740• USA- R-t 1.800.234.0227 TKHSERACFSR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAX+1.574.205.3455 www.niboaoom NIBCCY www.nibco.com AHEAD OF • Fd ybLt a%e TLUIj ng IFITTING SYSTEM -I NSERT/MMP TYPE MADE BY NI BOO Mab ng a GonnecA*im 1. Using a tube cutter, 2. 9 i de copper c i ap ring on tub ng.Only copper ai rrp ri rigs should be cut tubing squarely used to ensure the highest quality connection. and remove buns i 3. Insert fitting intotubing,then position crirrp ring squarely 4. Center the cri rr pi rig tool jaws exactly over the ri rig,andbring over barbs.Roper al ignment i s i nportant for rra4d ng the the tool handles together unti I totally dosed to the stop indicator.Check best oonnecti on. each cri rip ri ng with the cal i per gauge after completion. If the small flats on the gauge do not fit over the gimped ring, the ring is undercri roped.Qrt out any underai roped rings and fittings, and completely replace. 1 TOCLSAND RNGS • Use tools reomTra-dedbyfitting and tubingmanufacturers. Al I tool s mast make a ful I-d rd e cri mp. • Check tool adjustment at least dai l y and readjust as necessary. • Use cri rrp ri rigs of copper as recommended by NI BODING NIBDJING wadD FEADC LAR19Z5. 1516 MIDaEBLW ST.• 919-14ff IN 46516-4740• USA• R t 1.800.234.0227 TffiiS9RACESR-t 1.888.446.4226• FAX 1.800.234.055!• INTB:NA-1CNALS9RACER-t+1.574.295.3221• FAX+1.574.295.3455 www.niboaoom www.nibco.com AHEAD OF • FfeqwftlyAsked Q, 4ions ■ Q What is the pressure rating of agivenfitting? Q Can dissimilar rretals(.e.,copper and iron)beja red together A Ftti rigs are rated per Table 1ofASMEB16.22.The system rated withaat use ofdiel ect ricinsulatorsto prevent oorrosion? pressure shall betheIovestofthefitti ng,tubeorjant. A In most sitLAionsdissirriIarrretals(copper/iron/steel)can be janed successful lywithal usingdielectricinsulators.Factorsto consider: Q When copper fai Is in a system,what is the problem? 1. The composition of the two nL4als. A: MCSTCCMMCN: 2. Therateofliquidflo✓v past thetworretals. 1. Melocity—fluid isrrWragtoofast.RxDrn-endation: 3. Chemicals in the water which could enhance ordestroy 2-3 fps(0.0508.0.0762 m s)hot water 140°F 5-8 f ps(0.127- protective fi d ms. 0.2032 rT s)ed d water.Fifer to pages 68-93. 4. The relative areas of the two metals-unless the surface area 2. Turbulence—burrs left on the cut tubing causes a tumbl i ng of the less noble(steel)material is less that 51/o of the more effect causing localized erosion and eventual fai I ure. noble(copper)material,the need for a did ectri c separator is 3. Aggressive Waters—tend to cause pitting or green stai ni rig of not Needed.(Fai I ures due to gal vani c oorrosi on are very unusual fixtures.Aggressive,hard wel I waters that cause 0tti rig and only occur under very stri ct conditions.) typically are found to have total dissolved solids including 5.Local code requi rements. suflates and chlorides,a pH i n the range of 7.2 to 7.8,a high content of carbon diadde gas and the pressence of dissolved oxygen gas.Soft acidic waters that cause green staff ni ng Q What should the i rstal I er of copper unions lqm and do in order to typi cal I y tend to be more oorrosive.Low alkalinity,Iow assure a proper leak free installation? m neral izati on,pH I evel s of 7 or I over shoul d be avoi ded. A The fa I owi ng shoul d be done: LSSSCCMMCN: 1. Make sure the ground-jant(nating area of unionistail and 1. A ux Cbrrosi on—usi ng too mach fl ux when naW ng thread pi eves)are free of ni dcs and scratches. j a nts can potent i al I y I eave resi due and cause i sol ated 2. Spray the ground-j a nt area with a food grade si I i cone spray or corrosion.Flux shoul d be used span ngl y and system adequately apply bees wax to enhance seati ng. flushed. 3. Make sure al i gnnent of I i ne does not put lateral stress on the 2. Electrolysis—stray(D.C)current;inadequate grounding for the ground-jant seal. piping. 4. Make sure that excess solder(drop)ets)do riot reactor the 3. Sand or other solid particulates—erosionloorrosionproblens ground-j ci nt area. can oocur.Laver vel octies mast be rrai ntai ned if solids are present inflow media. 4. Cblvanic Corrosion—destructionofanatenal by electrochemcal interaction between the awronmant and the material. Q Copper tubi ng wed I thickness is designated"K,""L'or"M"What are the copper fitti rigs appl icabl e to? A Copper fitti ngs'wall thicvnessisdeteminedby standards(ASME B-16:22 and MSS-SP-1 04).These standards address rri ni mum wad I t hi dTess(per size)for the ful I range of copper fi tti rids and are riot i ntencled to natch tub ng wed I thidaesses. NIBOOINC WC DFFADCLARTB:S• 1516MIDDL®lR'ST.• RA-PRr,IN46516-4740• USA- R-t 1.800.234.0227 TKHSERMCFSR-t 1.888.446.4226• FAX 1.800.234.0557• INTB:NAnCNALSERACER-t+1.574.295.3221• FAx+1.574.205.3455 www.niboo.aom MIBCCY www.nibco.com AHEAD OF • p4Q�R W�ql�� RE)ddeftid 50-YEAR Oapper Ru-rb Roducts i �in�t,r,�cr�aaEa's 1 ■ Li ted WaTanty What the warranty terms mean What is not covered:Disclaimer of I i abi I i ty for consequential In this warranty"Manufacturer" refers to the oompanyIistedbelow and other damages which manufactured the Product and any person or company that The Manufacturer does NOTwarrant against failure: assumes its obligations under this warranty."Homeowner" means 1. of any product,parts,or systems that it has not manufactured; you as the owner of the residential building in the United States in 2. if the Product is used for purposes other than residential whi ch t he Product has been i nstal led and also means any suoceedi ng owner duri rig the on gi nal warranty term°Product" means t he copper p1 umbi ng appl i cat i ons; water tube and/or copper or brass fittings manufactured by the 3. caused by,contributed inwhdeor in part by,or resulting from, Manufact urer for theresi dent ialbuiIdingnmarketintheUnitedStates. any of the fdlowing: Each Manufacturer listed below separately and i ndi vi dual ly warrants (a) in-proper installation; only R-oducts it has manufactured and does not warrant Products of (b) abuse such as,without limitation,vandalism any other oorrpany,whether or not listed below. (c) natural disasters,such as,without limitation,flooding, Date the warranty begi ns windstormand lightning; The warranty begins on the date of the new home purchase, (d) attachments or modifications to the Product that the or in the case of home additions or renovations, on the date the Manufacturer did riot authorim; installation iscorrpleted.The warranty is transferable tosuoceeding (e) external causes, where external, physical or chemical Homeowners for the remainder of the original warranty term, in qualities produoe damage to the Roduct,such as,without which case the date the warranty begins shall continue without limitation,aggressive water or an unsuitable or hostile dnange. environment;or (f) any other cause beyond the Manufacturer's oontrd. What is covered The Manufacturer warrants to the Homeowner for a period The Manufacturer shall NOT be liable under any circumrstanoes for of 50 years from the date the warranty begins that its properly any other director any indirect,incidental oroonsequential damages installed Product will be free of failure as a result of defects in of any ld nd. material orworkmanshipinn-anufacturi rig the R-oduct. Thi s i s the onl y warranty What the manufacturer wi I I do for you This warranty is the only warranty for the Product provided by the As I ong as(1)such a fed I ure oocurs withi n 50 ears from the date the Manufacturer, and is and shall be in lieu of any and all other warranty begins and (2) the Homeowner promptly notifies the warranties,epress or i rrpl i ed,i nd udi ng but not I i mi ted to an i mpl i ed ManufactureroftheRroductof that fed lurebyoontactingit through its warrantyof merchantability andof JI other obligations or liabilities 800 phone nurrber listed below,the Manufacturer will correct that on the part of the Manufacturer. None of the Manufacturer's fai I ure by repairing or replacing the Roduct within a reasanabl e t i me, errpl oyees,and no of her person or business,i s aut hori zed to make without charge.Thiswarrantyislimitedtotheoost of repairingor any other warranty on the Manufacturer's behalf oovering the reel aci ng t he Roduct,i nd udi ng i nstal I ati on. product. N�� -N��'� � This warranty gives you specific legal rights,and you may also have other rights which vary f rom state to state.Some states do not al I ow 1-888446-4226 the exclusion or I i rritation of incidental or consequential damages,so the above limitation or exd usi on may not appl y to you. NIBDJING wadD FEADU-AR19Z5. 1516 MIDaEBLWSL• 9-W RVRr,IN 46516-4740• USA• R t 1.800.234.0227 Tffii SBRACES R-t 1.888.446.4226• FAX 1.800.234.055!• INT9:VATICNAL SBRACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.niboaoom www.nibco.com AHEAD OF • Numen Cd I rdex ■ Rgure Rgure Rgure Rgure Rgure Nun tier Fbge Number Page Number Page Number Page Nurter Page 100 Series 735.............................. 11 837..............................36 C--pper Insert Rttingsfor Cast Heavy Rared 736 ............................. 11 851..............................34 FblYe Nene(FEK) 101...............................23 739.............................. 16 851-C...........................34 FD(198.........................26 104...............................23 741............................... 15 861-LH.........................36 FD(..........................26 748 .............................21 875-S...........................40 F M.........................26 700 Series 749 .............................21 878..............................40 F12......................26 500 Series Cast Rared Cast Ressure 750................................8 879..............................40 FE-600-FA...................26 500..............................24 701..............................10 750-3.............................8 880..............................39 FD600-T......................26 503..............................23 701-D...........................10 750-4.............................8 881..............................39 FE)GM.........................26 504..............................23 702 .............................10 764.............................. 15 884..............................39 FD604.........................26 507..............................23 703................................6 771.............................. 16 885..............................39 MEN.........................26 507-3...........................23 703-2.............................6 775.............................. 16 890..............................39 FD(607-FA...................26 507-4...........................23 703-5............................6 891..............................39 FEM1511.........................26 511...............................24 703-513..........................6 892..............................39 FD707-3-5..................26 704................................7 800 Series Cast DM 892-3...........................39 F1EX341.........................27 7042.............................7 801..............................34 892-A..........................39 FD(100.........................27 600 Series 7042-H.........................8 801-2...........................33 F1616..........................27 Wrot Resst.re 704-F.............................7 801-2-7........................31 600................................9 704-H............................7 801-T...........................32 900 Series Wrot DJW 600-2........................... 15 705..............................16 802..............................32 901..............................34 600-DS........................ 10 705-D...........................17 802-C..........................32 901-2...........................33 600-F5 .........................9 706-2...........................12 802-F...........................32 901-2-7........................31 601.............................. 10 707..............................12 803..............................32 901-2-F........................33 603................................6 707-2-4........................13 803-2...........................32 901-7............................31 603-2.............................6 707-3...........................14 804..............................32 901-FP.........................34 604................................7 707-3-5........................14 8042...........................33 903..............................32 6042.............................7 707-3-5-A....................14 804-T...........................33 903-2...........................32 606.............................. 11 707-3-6........................14 805..............................31 903-7...........................31 606-2........................... 11 707-4...........................14 805-N..........................31 904..............................33 607.............................. 12 70746........................14 806..............................35 9047...........................31 607-2........................... 13 707-5...........................14 806-2...........................35 905..............................31 607-2-2........................ 13 707-5-A........................14 807..............................35 906..............................35 607-2-2-LT.................... 13 707-6...........................15 807-2...........................35 906-2...........................35 607-2-1......................... 13 708..............................15 807-3...........................36 907..............................35 607-2-LT....................... 13 710-3...........................17 807-4...........................36 907-2...........................35 607-1............................ 12 710-3-4........................17 807-9...........................36 907-LT..........................35 607-LT.......................... 12 711..............................19 808..............................36 911..............................37 611.........................17-19 711-5...........................19 809..............................36 917-B...........................37 611-2............................ 19 711-A...........................19 810..............................38 951..............................34 616.............................. 16 712..............................20 811..............................37 960..............................36 617................................9 712-5...........................20 811-14..........................37 618................................8 713 .............................20 811-15..........................37 618-3.............................8 714..............................20 812..............................38 Comer Insert Rttingsfor 619 ...............................8 717................................9 814..............................38 Fbly"ene 620-L............................8 717-D.............................9 816..............................33 FB198..........................29 621..............................21 718-3.............................8 816-S...........................33 FB600..........................29 623.............................. 16 7245-A ......................10 818ASA...................36 FB600-FiA....................29 624.............................. 16 733..............................21 834..............................38 FB607..........................29 633-W.........................21 733-2...........................21 835..............................37 FB607-FiA.....................29 638.............................. 16 733-3...........................21 835-B...........................37 FB611..........................29 698..............................20 733-4...........................21 836..............................38 NIBDDINC WCRDHE DaJ4Rfff5. 1516MIDDL®J;YST.• Rr4-IOW IN46516-4740• USA- R-t 1.800234.0227 TKH SERACE5 Rt 1.888.446.4226• FAX 1.800.234.0557• IN1B:?,A-1CNAL SERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.00m MIBCCY www.nibco.com AHEAD OF • NOTES NIBDJINCWCRDFEADCLART9T• 1516MIUIB3JWSf.• al+PRrIN465164740• US4• R-t1.800.234.0227 TEH SERACE5 PH 1.888.446.4226• FAX 1.800.234.0557• INTffi A-l1CNALSERACE R-t+1.574.295.3221• FAX.+1.574.295.3455 www.riiboo.00m www.nibco.com AHEAD OF • NOTES NIBMINCWCRDFEADQ14RTEM- 1516MICD-BBLWST.• aA-14 f,IN46516-1740• LISA- R-t1.806234.0227 TEH SERAC1B A-t 1.8B8.446.4226• FAX 1.800.234.0557• INT9aVAl1CNALSERACE R-t+1.574.295.3221• FAX+1.574.295.3455 www.riboo.com globally connects n ou at all level _ 17 It's a new age of business, and a new way at NIBCO. From Elkhart, Indiana to Lodz, Poland, and points beyond, our i company has integrated manufacturing, distribu- tion, and networked communica- tions to provide a seamless source of information and service, 24 hours a day, 7 days a week. But this integration hasn't hap- world pened overnight. It's been part Headquarters of a long-term strategic process Elkhart, that has pushed us to reconsid- Indiana er every aspect of our business. MANUFACTURING D I STRI BUT ION INTERNATIONAL The result?We're a vertically Metal Valves Plastic Pipe, ndustrial Pipe Hangers International U.S.& International Global Offices and Fittings Valves, Plastics &Support Distribution Centers integrated manufacturer with and Fittings systems the products and systems in -• place to deliver low cost and high quality. NIBCO's products -0 All are manufactured under a Quality Management System conforming to the current revi- sion of ISO-9001 International Standards. We know the flow control industry is only going to get more demanding, and we are more than ready. We will continue to lead. That's what NIBCO is all about. NIBOOINO WCRD Rt FS• 1516 Ml�kWST.• aA-Aff,IN 46516-4740• LSA• F-t 1.800.234.0227 TECH�ACB R-11.888.446.4716• FAX 1.800.336.4226• INT6+A_1CNAL CFRCE F-t+1.574.295.3221• FAX+1.574.295.3455 wwwAbco.corn — FITTINGS W rot and cast copper pressure fittings • W rot and cast copper drainage fittings• W rot copper FD4ink' fittings• Cast copper alloy flared fittings• Cast copper alloy flanges• ABS and PVC DW V fittings• Schedule 40 WC pressure " fittings• CWC CTS fittings• CWC CTSto4T-etal transition fittings• Schedule 80 PVC and CWC systems• CWC metric piping systems. VALVES & A CTUATI O N Riessure•rated bronze, iron and alloi gate, globe and check valves• Ressure- rated bronze ball valves • Boiler specialty valves • Commercial and indushial butterfly valves• Circuit balancing valves• Carbon and stainless steel ball valves AN SI flanged steel ball valves • Rheumatic and electric actuators and controls • Grooved ball and butterfly valves• High performance butterfly valves• UU FM fire protection valves• MSS specification valves• Bronze specialty valves• Low- pressure gate, globe, check and ball valves • Frostproof sillcocks • Quarter-turn supply stops• PVC ball valves• CWC CTS ball valves• Jd RgW recirculating valves C H EM TRO L® Thermoplastic pipe, valves and fittings in WC, Corzan® CWC, polypropylene and WDF Kynar" • Chem ire" thermoplastic compressed air piping systems • Pneumatic and electric actuation systems. CorzarP is a registered trademark of Noveon,IP Holdings Corp. Kynar`is a stered trademark of ATOHNA Chemicals Inc. TO LCO TM N IBCO' now offers complete support with its newest addition of TO LCO' brand piping solutions including: Rpe attachments• Structural attachments• Rpe rollers• Threaded products and accessories• Seismic components Vibration isolation • Standard and specialty supports• TOLStrut channel and components. eN I BCO A suite of services designed to make customers more efficient• More cost-effective • More informed • EOI—Electronic Data Interchange • VMI—\kndor Managed Inventory • N IBCO.com • N IBCOpariner.com • eN IBCO will continuously develop new products to deliver the competitive advantage. NIB AHEAD OF THE FLOW" N IBCO IN C. 1516 MIDDLEBURY STREET DOMESTIC CUSTOMER SERVICE TECHNICAL SERVICE INTERNATIONAL OFFICE W ORLD HEADQUARTERS ELKHART, IN 46516-4740 PHONE: 800.234.0227 PHONE: 888.446.4226 PHONE: +11574.295.3221 WEB: www.nibco.com USA FAX: 800.234.0557 FAX: 8 8 8.3 3 6.4 2 2 6 FAX: +1I 5 7 4.2 9 5.3 4 5 5 C-CF-0404 ©2004, NIBCO INC. Printed in USA tTOLCO" a brand of ■ - 00 Fig. 200 - "Trimline" Adjustable Band Hanger G @ US LISTED Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from i abrasion. Captured design keeps adjusting nut B from separating with hanger. Hanger is easily e r" installed around pipe. ' �- • (21/2" thru 8" Spring tension on nut holds it A A securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering ► f Approved (3/4" thru 8"). Conforms to Federal 112 THRU 2 INCH PIPE 2 112 THRU 8 INCH PIPE Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature—650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By— Figure number and pipe size Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/a 83/4 1250 136 ORaCFJMANUFACrURINGFACUTY•1375S4MPSCNA/E•OJUA CA 92879•R-t 951.737.5599•FAX 951.737.0330 � CUSTOM ER SERA CE-800.786.5266 www.tolco.com SAMMYS° FOR WOOD • - WOOD - Vertical Application Application Product Features Not less than Wood Flooring 2"nominal width •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill/driver. thickness(2-1/2") (depth or side Wood Joisf of vertical member) _ •Saves time from traditional methods. Double Sheetrock Ceiling •Reduces installation costs. Composite I Truss •Made in the U.S.A. Consult truss manufacturer for recommended installation point. 25-380. Approvals Rod Part Watch a video demonstration of .. www.itwbuildexcom Model Size Number D• Gty Qty MOUNT VERTICAL 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 Qn 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) °t,• 318" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 114 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 #14 Black O 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 114 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 V 400.. ° /�S MADE IN U.SA SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. • . • • •. - • . • • •-