Loading...
HomeMy WebLinkAboutB13-0062 REV1 TRANSMITTAL AND CUT SHEETS Department of Community Development 75 South Frontage Road Vail, CO 81657 TOWN OF VA I l Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s)information applies to: Attention: &Revisions I)Response to Correction Letter �3QG�J l 0_attached copy of correction letter (� O Deferred Submittal ON y Other Project Street Address: 100 P_ , M �'O"D b-. 1-so_ (Number) (Street) (Suite#) Building/Complex Name: 0 Description of Transmittal/List of, Changes, Items Attached: ck4,J G�i�r- �er Applicant Information (architect, contractor, owner/owner's rep) Contact Name: Address: City � State:�_Zip: (IGRIZ. Contact Name: �•-b.,�1C" YO��-� (use additional sheet if necessary) Contact Phone: — Z Building Permits: _ 1\ Revised ADDITIONAL Valuations (Labor& Materials) Contact E-Mail: �_1� a ' �`aS ��^� (DO NOT include original valuation) I hereby acknowledge that I have read this application, filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: $ comply with the information and plot plan, to comply with all Town or c&s and state laws, and to build this structure according Electrical: $ to t ng and subdivision codes, design review ap- 44 OC)D prove I er al Building and Residential Codes and other Mechanical: $ 2 ordinan of own applicable thereto. X Total: $0 .rC>Eb Owner/Owner's Representative Signature(Required) Date Received: For Office Use Only: Fee Paid: Received From: Cash Check# CC: Visa/MC Last 4 CC# exp.date: Authorization# Chernick Residence 100 E. Meadow Dr. Unit 30 :Ac'-c-3- 71 I—I V I her K3 NEW SOFFIT TO ACCOMMODATE NEW HUMIDIFIER SUPPLYS NEW HUMIDIFIER SUPPLY 36' RUN OF 6"ROUND DUCT FROM SUPPLY PLENUM CEILING LOWERED IN W.C. TO T-0"TO ACCOMMODATE NEW N HUMIDIFIER SUPPLYS NEW HUMIDIFI P IY B72 40' RUN OF 6" ROUND U FROM SUPPLY PLEN Chernick Residence 100 E. Meadow Dr. Unit 30 l o Q n ' i i + , ---- ANT Wit. HUMIDIFIER $ -C-dK�{ t; NEW-IiDI 1'DIFIER aji f.= r` SUPPLY SUPPLY 16' RUN OF 6" FOUND DUCT s3 FR']�uP-7'PLY ' PLENUM 01 VF 2 j { i EXISTING -- \ ! HUMIDIFIER I ! EXIS � •:4•�/• • jRETURN GRILL HIGH ;HUMI TAT FIN SOFFIT TO 12" OUND DUSj?/ --1! ' OMIT EXISTING �{�•! i�c'f}�I H Mu• HUMIDIFIER i \ r SUPPLY I - — N 6"HUMIDIFIER SUPP W. I.C. i' RUNS ROUTED'FROM A IC ,"°•, ABOVE TO W.C. BELOW --' 72- III e� NEW HUMIDIFIER SUPPLY 25' RUN OF 6" ROUND DUCT FROM SUPPLY PLENUM OtF C=0. �- o• , t Chernick Residence 100 E. Meadow Dr. Unit 30 REPLACE EXISTING BOILER AND WATER HEATER WITH NEW TRIANGLE TUBE SOLO 250 BOILER AND (TWO) TRIANGLE TUBE SMART 60 INDIRECT WATER HEATERS. INSTALLATION INCLUDES: NEW MIXING VALVES, ZONE VALVES, FLUSH AND FILL OF 30% EXISTING SOLUTION GLYCOL, EXPANSOIN TANK, AUTO-FILL HUMIDIFIER VALVE, BACKFLOW, EXHAUST VENTING AND HUMIDIFIER SUPPLY TO UNIT, FAN, COMBUSTION AIR PIPING THROUGH THE EXISTING INT. BEDROOM &PLENUM FLUE. UNIT IS 250,000 Btu AND 95% EFFICIENT. HIGH ON SOUTH WALL z2),22:' C PMrz5t*TJ0i ATte._ • - - .— .. ... . Lou�L-�t11 E ZZ'x'G`CILf� to_ N ON EXISTING 12" RETURN FROM CLOSE OFF HIGH S LIVING RM S �� }' EXISTING SOFFIT ; COMBUSTION AIR EXISTING 8" SUPPLY. ROUND__ 30 x 60 ATTIC EXISTING ACCESS HUMIDIFIER i TEAM UNIT ALL SUPPLYS TO Second & 117ird Floor Plans HAVE MANUAL DAMPERS IN ATTIC a SPACE 4 ii e � � Metfianlcai/PiufflUng : .OJ!1�-D��zvm t.,-Gt..! 4 ogre �utti'?1�1°,`j0 RT�H-lN F3Y: 'r�2 l ( xoas sage v4-r-a SOE--r t'}_: �! -- t,,t9°p c,.;:soru�n HUMIDIFIER SUPPLY HIGH 12 May 6, 2013 ON MASTER BED WALLt`..r'� %1A :oi tE Ex11.:?N zv'xz�' MECr;.L�,,N f C,& 200 CLAN TriangleTube 0 E T1 E S010 Condensing High Efficiencv Gas Boiler 4 Stainless Steel Fire Tube • Heat Exchanger 95% AFUE • Low Pressure Drop • Proven Performance • 2" to 4" Venting • 0 Multiple Termination Options • a Low NOx - 2012 SCAOMD Certified • 5 Models from 60 to 399 MBH • 0 2 Year Control & Blower Warranty • Featuring TriMax Control with: • 60 Second Set-Up • Integrated Cascade • Two Reset Curves/Set ` Points • Control of 4 Circulators ® T ,.R qp, prestige - Ledder in Con1f dclor Friendlq Fed [ ures TriMax Control 60 Second Set-Up Choose from 6 standard applications to set up the boiler in 60 seconds or less. • Finned Tube Baseboard • High Mass Radiant • Cast Iron Baseboard • Low Mass Radiant • Radiators • Fancoil Integrated Cascade Joins up to 6 boilers: Master boiler automatically recognizes linked boilers: z Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation. ® Multiple Zone & Circulator Contro, Manages 2 separate reset curves for high and low temperature zones: Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW zone without external zone control panel. Intelligent Troubleshooting ® Describes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for 24 hours. Next Generation Fire Tube Heat Exchanger High Water Content ' • Provides stable temperature control • Low sensitivity to water flow r• Reduces short cycling • Adapts to large or small heating loads Unique Geometry • Designed for maximum reliability with low thermal stress r • Improved water flow for maximum heat transfer • 439 Stainless Steel for corrosion resistance • Polypropylene condensate pan and flue resists corrosion Reliable Low Maintenance Desian • • Self cleaning design washes away combustion debris • 10 year history of reliable performance r.. • High performance burner design • Low pressure drop allows piping directly to the system prestige - Ledder in Contractor Friendlq features Prestige Solo 110 Exploded View Test Ports in both Flue and Air Connections IZ Integrated Circulator&DHW Supply on Solo 110 Model Simplifies piping and wiring i • Polypropylene Flue and Condensate Pan Eliminates corrosion from condensate Fold Down Control Panel Permits quick access to boiler internals Simplified Wiring Connections Wiring connections are well laid out and clearly marked. Fused high voltage connections makes trouble shooting easy The Widest Range of Venting and Termination Options Venting Terminations - 2", 3", and 4" diameters depending on model - Traditional PVC/CPVC/PP/SS piping elbows - PVC,CPVC, SS and Polypropylene materials - Flush-mount PVC for twin pipes - Flexible Polypropylene for chimney chases - Flush-mount Stainless Steel for twin pipes - Concentric (399 only) or twin pipe - Single hole Concentric Termination for twin pipes - Extended vent lengths up to 100 feet - Horizontal Concentric Termination (399 only) -Common Vent for multiple boilers (399 only) - Horizontal and Vertical Common Vent Terminations (399 only) Il Performance Specifications input Model Fuel 5'- DOE NET Water Aodulation Heating Capacity I=B=R Volume Solo 60 Natural or Propane 16 to 60 95% 54 47 2.5 S010110 Natural Gas 30 to 110 95% 99 86 2.5 Solo 110 LP Propane Gas 25 to 97 95% 87 76 2.5 Solo 175 Natural or Propane 50 to 170 95% 154 134 4.6 Solo 2 0 Natural or Propane 65 to 245 95% 223 194 4.1 Solo 399 Natural or Propane 112 to 399 95.1%' 379 330 7 Connections / Dimensions / Data 'Thermal Efficiency Supply Model Diameter - Solo 60 1' 112' 3' 16'x 20'x 35 112" 95 S010110 1• 1/2' 3" 16"x 20"x 35 1/2" 106 Solo 175 1 1/4" 3/4" 3' 16N 20'x 35 1/2" 131 1 1/4* 3/4' 3" 16"x 20'x 35 1/2" 142 Solo 399 1 11r 1" 4" 20 3/4"x 24 3/4'x 37 1/2" 200 TriMax Control Features Standard Features 1 Large Graphic Interface 1d Stainless Steel FireTube Heat Exchanger i 60 Second Set-Up Ild EZ Access Terminal Strips with Individually III Customizable Reset Curves with 6 Presets Fused High VoltageTerminals 1i Standard Modbus Interface 1d Outdoor Reset Sensor 1d 2 Space Heating Call Inputs 1111 Negative Pressure Regulated Gas Valve 1d Controls up to 4 Circulators 11 LP Conversion Kit Ild 0-10 VDC Modulation Input - _ - (All Models except Solo110) A Outdoor Reset Ild Cat IV Venting 111 Lockout Piping Connections Lockout Screens with Error Description and Troubleshooting recommendations: 1d Integrated Pressure Gauge Cascade Control for up to 6 Boilers -- - - -Auto-configure linked boilers NJ 30 psi Pressure Relief Valve - Simultaneous space heating & DHW capability i Automatic Air Vent - Full parallel modulation - Boiler rotation ld Fold-down Control Panel for Easy Access Ild DHW Priority i Condensate Trap Id Warm Weather Shutdown 10 Year Non-Prorated Heat Exchanger -- III Low Low Water Cut Off — 1111 2 Year Control & Blower Warranty Triangle Tube reserves the right to make product changes or improvements at any time without notice. 4�"f'FFO / 1 Triangle Lane Blackwood, NJ 08012 An A ISOlU01 �� Th a n g I eTu b e Tel: (856) 228 8881- Fax: (856) 228 3584.) E-mail: info @triangletube.com - http://www.triangletube.com Company 2011-48 Prestige Solo Lit.-Revised 1/17/13