HomeMy WebLinkAboutB13-0062 REV1 TRANSMITTAL AND CUT SHEETS Department of Community Development
75 South Frontage Road
Vail, CO 81657
TOWN OF VA I l
Tel: 970.479.2128
www.vailgov.com
Development Review Coordinator
TRANSMITTAL FORM
Use this form when submitting additional information for planning applications or building permits.
This form is also used for requesting a revision to building permits. A two hour minimum building review
fee of$110 will be charged upon reissuance of the permit.
Application/Permit#(s)information applies
to: Attention: &Revisions
I)Response to Correction Letter
�3QG�J l 0_attached copy of correction letter
(� O Deferred Submittal
ON y Other
Project Street Address:
100 P_ , M �'O"D b-. 1-so_
(Number) (Street) (Suite#)
Building/Complex Name: 0 Description of Transmittal/List of, Changes, Items Attached:
ck4,J G�i�r- �er
Applicant Information
(architect, contractor, owner/owner's rep)
Contact Name:
Address:
City � State:�_Zip: (IGRIZ.
Contact Name: �•-b.,�1C" YO��-� (use additional sheet if necessary)
Contact Phone: — Z Building Permits:
_ 1\ Revised ADDITIONAL Valuations (Labor& Materials)
Contact E-Mail: �_1� a ' �`aS ��^� (DO NOT include original valuation)
I hereby acknowledge that I have read this application, filled out Building: $
in full the information required,completed an accurate plot plan,
and state that all the information as required is correct. I agree to Plumbing: $
comply with the information and plot plan, to comply with all Town
or c&s and state laws, and to build this structure according Electrical: $
to t ng and subdivision codes, design review ap- 44 OC)D
prove I er al Building and Residential Codes and other Mechanical: $ 2
ordinan of own applicable thereto.
X Total: $0 .rC>Eb
Owner/Owner's Representative Signature(Required)
Date Received:
For Office Use Only:
Fee Paid:
Received From:
Cash Check#
CC: Visa/MC Last 4 CC# exp.date:
Authorization#
Chernick Residence
100 E. Meadow Dr. Unit 30
:Ac'-c-3-
71
I—I V I her
K3
NEW SOFFIT TO
ACCOMMODATE NEW
HUMIDIFIER SUPPLYS NEW HUMIDIFIER SUPPLY
36' RUN OF 6"ROUND DUCT
FROM SUPPLY PLENUM
CEILING LOWERED IN W.C. TO
T-0"TO ACCOMMODATE NEW
N
HUMIDIFIER SUPPLYS
NEW HUMIDIFI P IY B72
40' RUN OF 6" ROUND U
FROM SUPPLY PLEN
Chernick Residence
100 E. Meadow Dr. Unit 30
l
o Q n ' i i +
,
----
ANT Wit.
HUMIDIFIER $ -C-dK�{ t; NEW-IiDI 1'DIFIER aji f.= r`
SUPPLY SUPPLY 16' RUN OF
6" FOUND DUCT
s3 FR']�uP-7'PLY
' PLENUM
01 VF
2 j {
i EXISTING --
\ ! HUMIDIFIER I ! EXIS � •:4•�/•
• jRETURN GRILL HIGH ;HUMI TAT
FIN SOFFIT TO 12"
OUND DUSj?/ --1! ' OMIT
EXISTING �{�•! i�c'f}�I
H Mu• HUMIDIFIER i
\ r SUPPLY
I - — N 6"HUMIDIFIER SUPP W. I.C.
i' RUNS ROUTED'FROM A IC ,"°•,
ABOVE TO W.C. BELOW --' 72- III
e�
NEW HUMIDIFIER SUPPLY
25' RUN OF 6" ROUND DUCT
FROM SUPPLY PLENUM
OtF
C=0. �-
o• , t
Chernick Residence
100 E. Meadow Dr. Unit 30
REPLACE EXISTING BOILER AND WATER HEATER
WITH NEW TRIANGLE TUBE SOLO 250 BOILER AND
(TWO) TRIANGLE TUBE SMART 60 INDIRECT WATER
HEATERS. INSTALLATION INCLUDES: NEW MIXING
VALVES, ZONE VALVES, FLUSH AND FILL OF 30%
EXISTING SOLUTION GLYCOL, EXPANSOIN TANK, AUTO-FILL
HUMIDIFIER VALVE, BACKFLOW, EXHAUST VENTING AND
HUMIDIFIER SUPPLY TO UNIT, FAN, COMBUSTION AIR PIPING THROUGH THE EXISTING
INT. BEDROOM &PLENUM FLUE. UNIT IS 250,000 Btu AND 95% EFFICIENT.
HIGH ON SOUTH WALL
z2),22:' C PMrz5t*TJ0i ATte._
• - - .— .. ... . Lou�L-�t11 E ZZ'x'G`CILf� to_
N ON
EXISTING 12"
RETURN FROM CLOSE OFF
HIGH S LIVING
RM S �� }' EXISTING
SOFFIT ; COMBUSTION AIR
EXISTING 8"
SUPPLY.
ROUND__
30 x 60 ATTIC EXISTING
ACCESS HUMIDIFIER i
TEAM UNIT
ALL SUPPLYS TO
Second & 117ird Floor Plans
HAVE MANUAL
DAMPERS IN ATTIC
a
SPACE 4 ii e � � Metfianlcai/PiufflUng
: .OJ!1�-D��zvm t.,-Gt..! 4 ogre �utti'?1�1°,`j0 RT�H-lN F3Y: 'r�2
l ( xoas sage v4-r-a SOE--r t'}_:
�! -- t,,t9°p
c,.;:soru�n
HUMIDIFIER SUPPLY HIGH 12 May 6, 2013
ON MASTER BED WALLt`..r'� %1A :oi tE Ex11.:?N zv'xz�'
MECr;.L�,,N f C,& 200 CLAN
TriangleTube
0 E
T1 E S010
Condensing High Efficiencv Gas Boiler
4
Stainless Steel Fire Tube •
Heat Exchanger
95% AFUE •
Low Pressure Drop •
Proven Performance •
2" to 4" Venting •
0 Multiple Termination Options • a
Low NOx - 2012 SCAOMD Certified •
5 Models from 60 to 399 MBH • 0
2 Year Control & Blower Warranty •
Featuring TriMax Control with:
• 60 Second Set-Up
• Integrated Cascade
• Two Reset Curves/Set `
Points
• Control of 4 Circulators
® T ,.R
qp,
prestige - Ledder in Con1f dclor Friendlq Fed [ ures
TriMax Control
60 Second Set-Up
Choose from 6 standard applications to set up the boiler in 60 seconds or less.
• Finned Tube Baseboard • High Mass Radiant
• Cast Iron Baseboard • Low Mass Radiant
• Radiators • Fancoil
Integrated Cascade
Joins up to 6 boilers: Master boiler automatically recognizes linked boilers:
z
Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation.
® Multiple Zone & Circulator Contro,
Manages 2 separate reset curves for high and low temperature zones:
Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW
zone without external zone control panel.
Intelligent Troubleshooting
® Describes lockouts in plain english and suggests solutions: Stores last 8
errors. Records sensor readings for 24 hours.
Next Generation Fire Tube Heat Exchanger
High Water Content '
• Provides stable temperature control
• Low sensitivity to water flow r• Reduces short cycling
• Adapts to large or small heating loads
Unique Geometry
• Designed for maximum reliability with low thermal stress r
• Improved water flow for maximum heat transfer
• 439 Stainless Steel for corrosion resistance
• Polypropylene condensate pan and flue resists corrosion
Reliable Low Maintenance Desian •
• Self cleaning design washes away combustion debris
• 10 year history of reliable performance
r..
• High performance burner design
• Low pressure drop allows piping directly to the system
prestige - Ledder in Contractor Friendlq features
Prestige Solo 110 Exploded View
Test Ports in both Flue and Air Connections
IZ
Integrated Circulator&DHW Supply on
Solo 110 Model
Simplifies piping and wiring
i
•
Polypropylene Flue and Condensate Pan
Eliminates corrosion from condensate
Fold Down Control Panel
Permits quick access to boiler internals Simplified Wiring Connections
Wiring connections are well laid out
and clearly marked. Fused high voltage
connections makes trouble shooting easy
The Widest Range of Venting and Termination Options
Venting Terminations
- 2", 3", and 4" diameters depending on model - Traditional PVC/CPVC/PP/SS piping elbows
- PVC,CPVC, SS and Polypropylene materials - Flush-mount PVC for twin pipes
- Flexible Polypropylene for chimney chases - Flush-mount Stainless Steel for twin pipes
- Concentric (399 only) or twin pipe - Single hole Concentric Termination for twin pipes
- Extended vent lengths up to 100 feet - Horizontal Concentric Termination (399 only)
-Common Vent for multiple boilers (399 only) - Horizontal and Vertical Common Vent Terminations (399 only)
Il
Performance Specifications
input Model Fuel 5'- DOE NET Water
Aodulation Heating Capacity I=B=R Volume
Solo 60 Natural or Propane 16 to 60 95% 54 47 2.5
S010110 Natural Gas 30 to 110 95% 99 86 2.5
Solo 110 LP Propane Gas 25 to 97 95% 87 76 2.5
Solo 175 Natural or Propane 50 to 170 95% 154 134 4.6
Solo 2 0 Natural or Propane 65 to 245 95% 223 194 4.1
Solo 399 Natural or Propane 112 to 399 95.1%' 379 330 7
Connections / Dimensions / Data 'Thermal Efficiency
Supply Model Diameter -
Solo 60 1' 112' 3' 16'x 20'x 35 112" 95
S010110 1• 1/2' 3" 16"x 20"x 35 1/2" 106
Solo 175 1 1/4" 3/4" 3' 16N 20'x 35 1/2" 131
1 1/4* 3/4' 3" 16"x 20'x 35 1/2" 142
Solo 399 1 11r 1" 4" 20 3/4"x 24 3/4'x 37 1/2" 200
TriMax Control Features Standard Features
1 Large Graphic Interface 1d Stainless Steel FireTube Heat Exchanger
i 60 Second Set-Up Ild EZ Access Terminal Strips with Individually
III Customizable Reset Curves with 6 Presets Fused High VoltageTerminals
1i Standard Modbus Interface 1d Outdoor Reset Sensor
1d 2 Space Heating Call Inputs 1111 Negative Pressure Regulated Gas Valve
1d Controls up to 4 Circulators 11 LP Conversion Kit
Ild 0-10 VDC Modulation Input
- _ - (All Models except Solo110)
A Outdoor Reset Ild Cat IV Venting
111 Lockout Piping Connections Lockout Screens with Error Description and
Troubleshooting recommendations: 1d Integrated Pressure Gauge
Cascade Control for up to 6 Boilers -- - -
-Auto-configure linked boilers NJ 30 psi Pressure Relief Valve
- Simultaneous space heating & DHW capability i Automatic Air Vent
- Full parallel modulation
- Boiler rotation ld Fold-down Control Panel for Easy Access
Ild DHW Priority i Condensate Trap
Id Warm Weather Shutdown 10 Year Non-Prorated Heat Exchanger
--
III Low Low Water Cut Off —
1111 2 Year Control & Blower Warranty
Triangle Tube reserves the right to make product changes or improvements at any time without notice.
4�"f'FFO / 1 Triangle Lane Blackwood, NJ 08012 An A
ISOlU01 �� Th a n g I eTu b e Tel: (856) 228 8881- Fax: (856) 228 3584.)
E-mail: info @triangletube.com - http://www.triangletube.com Company
2011-48 Prestige Solo Lit.-Revised 1/17/13