Loading...
HomeMy WebLinkAboutDRB130155 PLANS.pdf r- - D RB 130155 v ry o L—) r__ J O Q H � Q O� W Ol POTATO PATCH PV • i_ J O� V Q LOT 31 . 809 POTATO PATCH, VAIL, COLORADO v Lu o W GENERAL NOTES: PROJECT SUMMARY: SYMBOLS : DRAWING INDEX I. DO NOT SCALE DRAWINGS. SURVEY 2. VERIFY ALL DIMENSIONS, CONDITIONS,AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY Code: 0001 EXISTING TOPOGRAPHIC SURVEY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR IV DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. INTERNATIONAL RESIDENTIAL CODE 2012 Section Cut Reference Detail Area Reference LANDSCAPE 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN Zoning: LI SITE/GRADING PLAN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. TWO FAMILY PRIMARY/SECONDARY EL: o'-o" L2 TURNING RADII PLAN L3 DETAILS AND NOTES 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL,TIMBER, STUD COLUMNS, OR • Occupancy Classification: Elevation Reference Elevation Symbol L4 PLANTING PLAN FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE,TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS TYPE R DIV. 3 OTHERWISE NOTED. a4 1A A_20 ARCHITECTURAL 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE Required Spri n kleri ng: AOO I HOUSE 31 GRFA PLANS BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES,TOILETS,TOILET Detail Cut Reference Large Area Detail Reference A002 EXTERIOR SITE LIGHTING ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. Conform to N FPA 13–D AI00 UNIT A CRAWL SPACE • Q6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR 12/31/1999 A101 UNIT A FIRST FLOOR PLAN TYPES. A102 UNIT A SECOND FLOOR PLAN SIC Revision Cloud Revision Symbol A103 UNIT A THIRD FLOOR PLAN 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR A104 UNIT A ROOF PLAN WINDOW TYPES. A105 UNIT B FIRST FLOOR PLAN 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR O O A 1 O6 UNIT B SECOND FLOOR PLAN AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. Grid Bubble Material Tag A107 UNIT B THIRD FLOOR PLAN 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR A108 UNIT B ROOF PLAN FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT,THEY SHALL IMMEDIATELY NOTIFY THE A I I O UNIT A CRAWLSPACE ELECTRICAL PLAN ARCHITECT. FAILURE TO GIVE 1 0 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY A I I I UNIT A FIRST FLOOR ELECTRICAL PLAN IN THE PROJECT. Al 12 UNIT A SECOND FLOOR ELECTRICAL PLAN 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES Al 13 UNIT A THIRD FLOOR ELECTRICAL PLAN AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE A 115 UNIT B FIRST FLOOR ELECTRICAL PLAN INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE AI I6 UNIT B SECOND FLOOR ELECTRICAL PLAN IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES PROJECT TEAM NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL A117 UNIT B THIRD FLOOR ELECTRICAL PLAN CODES. A201 ELEVATIONS ARCHITECT: LANDSCAPE ARCHITECT: 1 I. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND K.H. WEBB ARCHITECTS P.C. FIELDSCAPE DESIGN A202 ELEVATIONS OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR 710 W. LIONSHEAD CIRCLE, UNIT A P.O. Box 1871 A301 BUILDING SECTIONS DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER VAIL, CO 81657 Avon, Colorado 81620 A310 WALL SECTIONS STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE PH. 970.477.2990 (970) 328-4006 ph. A501 DETAILS CONSTRUCTION. CONTACTS; (970)328-4212 fax KYLE H. WEBB CONTACT: A502 DETAILS 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE MICHAEL CURRENT RIC FIELDS A601 EXTERIOR WINDOW AND DOOR SCHEDULE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. A602 DOOR DETAILS Lj A603 WINDOW DETAILS AND INTERIOR DR SCHED 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF& DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE&SNOW TO ENSURE MINIMAL STRUCTURAL ENGINEER PROBLEMS WITH THESE SURFACES. KRM CONSULTANTS, INC. Q LLJ PO BOX 4572 14. SUBSTITUTIONS OF"EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN O VAIL,CO 81658 M c Q APPROVAL. PH. 970.949.9391 = ac 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR FX. 970.949.1 577 gr o AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION,SUPPLIES, CONTACT: 0 �� OV EQUIPMENT, ETC.TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE MIKE STRUMPH O J INDUSTRY. t— O 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE Q J SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING O UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR P R 0 J E C T LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. DRAWN BY : D A T E : 05.13.13 REVISIONS : PERMIT 01.30.01 RECEIVED CD 10. 3.01 RE-ISSUE 05.113.13 Date: 05 / 13 / 2013 TOWN O VAILC By: D . RHOADES COVER AOOO 1 I SEWER MANHOLE 0520 � r 0.3 I LOT 32 NOTES: MEAS. RIM=8570.1 I � 0 1) DATE OF SURVEY: 10/31/06 00 LO (°o in 00 I 2) SURVEYOR HAS MADE NO INVESTIGATION OR INDEPENDENT SEARCH FOR AMENDED 0 PLATS, EASEMENTS OF RECORD (OTHER THAN PLATTED), ENCUMBRANCES, I I ROCK RESTRICTIVE COVENANTS, OWNERSHIP TITLE EVIDENCE, OR ANY OTHER I WALL FACTS THAT AN ACCURATE AND CURRENT TITLE SEARCH MAY DISCLOSE. O PLANTER I 3) NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL 00 ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS O AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY 0.1 ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE FOUND PIN & S1 8'00'26"W 143.99 00 THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN YELLOW PLASTIC HEREON. CAP LS#11413 0.3 1 4) BASIS OF ELEVATION: SEWER MANHOLE 0540 INVERT=8565.6 (SEE DRAWING). \ I GAS METER 5) BASIS OF PROPERTY LINE LOCATION: MONUMENTS FOUND ON LOT (SEE DRAWING). 0.3 g I 6) BEARINGS AND DISTANCES ALONG PROPERTY LINES SHOWN HEREON ARE AS SHOWN ON THE SUBDIVISION PLAT ONLY. A BOUNDARY SURVEY WOULD I I 0.2 BE NECESSARY TO DETERMINE THE TRUE DIMENSIONS OF THE LOT AND I SETBACKS, WHICH MAY VARY FROM THE PLATTED DIMENSIONS. I 7) THIS ENTIRE LOT FALLS WITHIN A MEDIUM SEVERITY ROCKFALL HAZARD AREA ACCORDING I TO OFFICIAL ROCKFALL HAZARD MAP OF TOWN OF VAIL, COLORADO AS ADAPTED BY COUNCIL ON OCTOBER 17, 2000 IN ACCORDANCE WITH RESOLUTION NO. 13 SERIES OF 2000. I 8) 2' CONTOUR INTERVAL. � I 9) NO BUILDINGS ON LOT. I 10) BUILDING SETBACK INFORMATION IS NOT PLATTED. PRIOR TO ANY DESIGN I O' ROCK OR CONSTRUCTION IMPROVEMENTS ON THIS PROPERTY, TOWN OF VAIL 0.2 W, WALL SHOULD BE CONTACTED FOR CORRECT BUILDING SETBACK INFORMATION. I 1 4_1 I I � O I �O. m Io \ co v z 0 \ I 0 0.2 X.X DENOTES CONIFEROUS TREE WITH APPROXIMATE TRUNK DIAMETER 6.0 0 0 Im 00 0.3 r 15.0 0 eF r ^� 4 0 30' UTILITY EASEMENT \ R cR I �� / 8633.7 X.X DENOTES DECIDUOUS TREE WITH APPROXIMATE TRUNK DIAMETER I N PE�K � �� I / �- - - - p - - - - - - - - - - - - - - VIEW-HIGH PEAK LOT 31 0 - - - - - - - - - - - VIEW 0.482 ACRES ° PLANTER N POINT 20987 SQ. FT. X. DENOTES BUSH WITH APPROXIMATE DIAMETER 8634.7 ROCK I < PHONE 1.,.� I � l W 1 PED / J I / cv ao ��P I y M / 8634.2 TRACT A 0 � of �,� r BLOCK 1 I 4.0 0 LO 00 I � /�\� I / R=62.607„ 8 L=24.89' T=12.61' 8633.01 C LEN=24.73 % BRG=N39'43 56 W O II 1 GUARD RAIL I I 20' ELECTRIC UTILITY O 0' 10' 20' 30' EASEMENT 6.0 / I (NOTE ON PLAT) 8632.1 p=1333'34" 30.0' I I R=174.64' I L=41.33' I 1 WATER �� T=20.76' I CURB C LEN=41.23 I STOP % BRG=N57'54'50"W I 1 4,0 i U 00 �t FOUND PIN & �4cr 10.0' 0 EDGE ASPHALT ROAD I YELLOW PLASTIC 2�•. 20 Q CAP LS#11413 / F 01 i a 8630.1 I � � O 10.0' ; F- I �O ryo I I - N06 )k8630.2 � I I / °o I \ ELECTRIC / 1 TRANSFORMER � o FOUND PIN & YELLOW PLASTIC o CAP LS#11413 ELEV=8549.66 SURVEYOR'S CERTIFICATE I, Michael J. Post, a Professional Land Surveyor registered under the laws of o the State of Colorado, do hereby certify that this topographic survey was ,(0 made by me and under my supervision, and that the survey is accurate and O 00 00 correct to the best of my knowledge. � O --------------------------- SEWER MANHOLE 0540 Michael J. Post INVERT=8559.4 Colorado P.L.S. 30116 MEAS RIM=8565.6 LOT 30 BASIS OF ELEVATION Date:------------ TOP❑GRAPHIC SURVEY LOT 31, BLOCK 1 VAIL/P❑TAT❑ PATCH TOWN OF VAIL HIGHWAY 6 & 24, EAGLE-VAIL cool P.O. BOX 12 EAGLE COUNTY, COLORADO EDWARDS, CO. 81632 (970)949-1406 3086TOPO.DWG 11/06/06 KPJ JOB NO. 3086 1 0 N � N i a 3 � DD � o U w \ 7 0 \ � °o � O O � a Tract A, Block 1 Z' S job No. 0714.00 Unit 32A \ Issue Date Final DR13 May 29, '07 Revisions June 5, '07 Permit July 23, '07 t. 17, '07 Revisions Se I I / P l I I 25 e SEWER MANHOLE 0520 MEAS. RIM=8570.1 / 1 ' —� 72 O / \ 1 - T,o 0 120 6 6 S 84 86 $$ 92 94 96 I � � 8 I 2.0 670 0 I 02 4 6 S 10 12 14 16 1g ` 0\0 1 I ' \ °0° @� Property Line �. r I T.O. O6 10: •� 5.s �r Stone X C� Dated a er s. _ o � Patio „ D / V 15' Side Setb 2: o sb2o O ILL Family Room Entry \ o�`�� ...r E 4 8603.00' FFE 8619.0' etiba I 1� I 2s° 191 U • N J 2 � \� 2 nit 31B 26 `� U 34 s`�0 ' 151 s.f 2� li-Q1 C/) @ S% Garage FFE 8619.25' (� 8635.9 8637.2 38 o se d Roof Elevations s63a. ons Re. Arch. O I Limit of / Pede al 5 34 �� � O `n D plex � � ���� � X isturbance 8 4.7 \ I I Garage I V/ FFE 32.0' ch 'Dr i v � O M 34. X8634.2 � M Unit 31A Entry �_?8'�„ X, �4-1 U 12• FFE 802.0' A S ,,, 0 4-1 Snow Storage Calculations: Heated er � g a Total Driveway surface area. 1, N� Dr LL Family Room 33. 846 s.f. O fit -+--+ FFE 8 Y Snow Storage Area Provision: 276 s.f. M I602.00 I 3 � g O -I.1 -Hot 2 8633.01 Area Required (10 /o paved area): 184 s.f. O O "Tub 1 �� 20 Utility 1 C onni ti o,w. Stone 149 s.f. no ��' eabl ` Unheated T wide concrete pan •r.q st°rage 3 3 \N Patch Drive R.O.W.on a /e I per T.O.V.requirements Site Coverage Calculations: N Patio � o� � �� �f; Heated Paver Drive in the Potato Total Lot area: 20,987 s.f. � 9 / I'm 8632.1 separate zone Impermeable Area: 6,996 s.f. (33.33%) 4,184 s.f. building U O � 1,846 s.f. driveway r� ck�99. I / 201/�15 ia,Setba Water Curb / / 675 s.f. patios ' T 95.3 5.3' p 1 �OYtr Permeable (landscaped) Area: 13,991 s.f (66.67%). I' � 0-5 12 14 16 1$ I Total Disturbed area: 12,242 s.f. (58.33%) 9 8614 / 06 O$ \ I / 24 / 8630.1 O I N 9� $ I 94 96 Electric Scale - 1" = 10'-0" I I90 92 I Transfor ®Copyright $5 I \ mer I I I f All Rights Incorporated 8630.2 I I \ All Rights hts Reserved \ / / This document,and the ideas and Site Plan I I I I \ in designs instrument rotes Tonal sere an instrument of professional.service, is the property of Fieldscape Incorporated and is not to be used, I in whole or in part,for any other project without the written authorization of Ric Fields. \ Sheet L I of four 0 8 � N m m .- m g O N d R o s O x F G p O M 7 � X q M ~ m 3 d 0 WTiaN 0 Ct-. Jr Job No. 0714.00 Issue Date Final DRB May29, '07 Revisions June 5, '07 Permit July 23, '07 c SIT O gi O Unit 32A I Unit 32A I II � 0 II 0 U Enhy r t E - QY.a� U .ore t Proposed =- Duplex 8 � � rage Cb DFi � e Proposed 5O o e a H Duplex � � �, a C age Y x 1 v - UO 1� , / zt Cn Y0 S T 0 Y J f � V LL Family Room Lt � i Family Room o iam 4- 050 4-j / 0 4-j I x � 1 0 0 NoYth � 0 Scale - 1" = 10'-0" Turning Radius Plan Fields pe lnmrymad an aigmsrs�eawee Thla docvmm4 and Ne ideas and designsinrorpo ared hereiry as an inslmmenl of p[ofes'sional s'e[via. ie rhepmpmy of Fieldam�e InroryorafM and is nonobe uud, 'n M1ole or in Dart(or anY Ofher a- wifhnn[Me written u�orriza mmf 2c F" Ids. Sheet L2 of four O � N 0C) N DD � m W ° O m o C O o X U w General Notes and Specifications 1. Location of all trees shall be staked by the Contractor and approved by the Landscape a Architect prior to final installation. C o 2. Exact placement and shape of planting beds shall be reviewed by the Landscape N o Architect prior to installation of irrigation system. 3. All plant material shall be backfilled with one part peatmoss/compost mixture with V O two parts topsoil. a�, 4. All plants shall be "Colorado Grown'; if not available 'Colorado Fielded', or 'Northern e 1-0' Min. Diameter Boulders Grown' may be acceptable. 5 0 1 5. Spruce trees to be nursery grown with leader intact and undamaged. tit _ Job No. 0714.00 6. All herbaceous planting beds shall be amended with well rotted manure/compost mixture I I Issue Date (one cubic yard compost per 350 s.f. one cubic yard sphagnum peatmoss per 250 s.f.) and tilled into rock free topsoil to a minimum depth of 6'. -I I Mirafi 700x or Equlant as needed to Final DRB May 29, '07 7. All herbaceous beds shall be top dressed with 1' extra fine shredded hardwood bark mulch. N I I-III- I I--- -i Maintain Gravel Behind Boulders Revisions June 5, '07 8. All shrub beds and tree wells shall receive a minimum of 3' shredded hardwood bark mulch. - I -III- Permit July 23, '07 9. All plant beds shall receive Mira-fi filter fabric or equal. 1 I I III= Key Sotto oulders by 18' Min. 10. Place a variety (species and bloom time) of perennials and ground covers in masses (min. 6 plants) where designated on the plan. Plant masses of bulbs in perennial beds. o I- 11. All deciduous trees 2-1/2" cal. and over shall be staked with 6' steel 'T' stakes and Native Seed Revegetation Specifications 4 I I I-I guyed with #14 gauge galvanized wire and 1-1/2" wide x 18' green nylon tree straps; I-I I all trees less than 2-1/2" cal. shall be staked by 6' lodgepole stakes with the same III I II I II guying and wrapping specifications. Native Seed Mix 9: I- 12. All deciduous trees shall be provided with a tree well at its base. Wells are to be Grass Seed: 'Multi-Color High Altitude Seed Mix' Mix as available from Arkansas earth constructed having a minimum shallow depth of 4" Valley Seed Company, Denver, CO (303-920-7300) 13. All newly planted trees shall be rootfed at time of installation. Rootfeeding shall a�. consist of a liquid root growth stimulator, including vitamin B-2 and a slow release Grass Seed Mix: e /��/�\/\\/�� ��/\/\/ \/\ fertilizer composed of 14+14+10+2% iron. Ephraim Crested Wheatgrass 30% 21 lob /X /� 14. All trees, shrubs, vines and mixed flowers shall receive drip irri ation at a schedule 3/4��ft/% consistent with their individual needs. All sod areas shall receive s irrigation with Dwarf Perennial Ryegrass 20% spray g Blue Fescue 20% Compact Backfill to 90% 3/4" to 1-1/2" Crushed Rock or Equivelant 100% overlap. All disturbed areas to be revegetated with native grasses and wild- Min. Standard Proctor flower seed shall receive temporary irrigation for a minimum of 30 days; thereafter, Reubens Canada Bluegrass 15% decrease water application gradually. This system will have an automatic clock with Chewings Fescue 10% Mirafi 140N Fabric or Equivelant an integrated rain sensor/shut-off. Wildflower Seed 5% 15. Aspen trees shall be field collected with a minimum of three clear trunks unless otherwise Install Lateral Drain 20-0" O.C. w/4" PVC Pipe or Gravel. specified. Grass Seed: 10 oz. per 1000 sq. ft. P.L.S. Slope Drain at 1/4' Drop per 1 Lineal Foot of Drain. 16. Unless otherwise noted by the drawings or technical specifications, all planting beds shall Native Seed Mix: 9-10 oz. per 1000 sq. ft. P.L.S. be separated from sod and native seed mix by Bend-A-Board edger. Typical Q 17. One application of di-ammonium phosphate fertilizer, 18-46-0 shall be broadcast prior Straw Mulch: Boulder Wall ►-d to seeding at a rate of 7-8 lbs. 1,000 s.f. Clean oat or wheat straw well seasoned before bailing, free from mature 2�1 18. All disturbed areas located on the Landscape Plan to receive native grass treatment seed-bearing stalks or roots of prohibited or noxious weeds. Not to Scale shall be revegetated by sewing the following seed mixture at a rate of 42 lbs./acre. Q 19. Percent mix of each seed type shall be approved by the Landscape Architect. r--a Seed Seeding: Q Sheep Fescue 20 Mix Loosen soil of seeded areas to depth of 4" U Creeping Red Fescue 20 Grade soil of seeded areas to smooth even surface with moderately coarse Canada Bluegrass 20 texture Canby Bluegrass 20 Apply seed at specified rates in (2) equal sowings at right angles to each other r=111111111111 4-1 Rocky Mountain Wildflower Mix 20 Place straw within 24 hours (2) 50 lb. balls per 1000 s.f., crimp into soil M 20. All areas to receive wildflower seeding shall be sown with the following mix of wildflower seed. Percent mix of each seed type shall be approved by the Landscape Architect. Temporary Erosion Control U Straw bale siltation berms shall be utilized during the construction and landscaping Seed % Mix Siberian Wallflower 15.08 periods. Berms shall be located according to the plans and as required to control Perennial Lupine 13.08 run-off and shall be installed prior to excavation. Sweet Williams Pink 12.04 0 Rocky Mountain Penstemmon 12.04 Water dissipaters shall be installed at intervals in drainage swales not to exceed 25' o.c. - w Perennial Gallardia 12.04 t--a Blue Flax 10.04 O ' The Contractor shall be responsible for preventing the release of sediment-laden water Dwarf Cornflower 6.04 `4H (mud) from the construction site, and shall be required to install additional control ,,� Annual Baby's Breath 6.04 facilities at the direction of the Owner or Owner's Representative, should problems U Corn Poppy 3.04 California Poppy 3.00 occur. Q Dame's Rocket 3.00 Shasta Daisy 3.00 All slopes greater than 2:1 will receive jute mesh erosion control fabric until Giant Columbine 1.00 revegetation grasses are established. 7 White Yarrow .32 r-� Q Aspen Daisy .24 Protecting Natural Features: Heated Drive withing R.O.W. cu, V The area of disruption will be completely fenced to protect surrounding undisturbed 14-1 V) ••�•J 21. All seed, sown and fertilized areas are to be lightly raked into soil. ,� 22. Mulch all sown areas with 2-3 of straw or hay free of weeds. vegetation. The areas which are not landscaped but within the disruption zone will be on a separate zone .r-.q U 23. All straw mulched areas are to tackified with an approved organic tackifier at the rate revegetated to match the natural vegetation. �-' � of 1201bs. per acre. bA T-0' 24. All finish grades shall provide for natural run-off of water without low spots or pockets. All existing trees designated to remain will be surrounded with snow fence installed at Set flow lines accurately and provide a minimum 2% and a maximum 33% gradient unless the drip line. The fencing will remain through the entire construction period. Asphalt Road 4-1 otherwise noted. Contractor shall be responsible for positive drainage throughout the Heated Drive C-A M site, with accurately set flow lines. No low spots or ponding of water will be accepted (paving to be selected) Proposed Drive O 4-1 in the final work. Positive drainage shall occur away from all improvements. 25. 'Specimen' plant material shall be flagged at the holding nursery for approval from the - ' •°° ____=III=III- 0 � -, Landscape Architect. _- - I- ` I I I-I I I-I I II I I-I I I 26. Plant quantities in the Plant Schedule are for information only. Landscape Contractor is _ _ _ _- I II I II I I-I I II I I-I I I _ _ _ _ I-I I II I I-I I II I I-III= responsible to do their own quantity takeoffs for all plant material on the plans. In ;I I I-I I I-I I I-I I IEI I IEI I IEI I I-I I I-I I I-I I I-I I IEI I I-I I I-I -I I I I I I-I I I-I I IEI I I-I 11 I -� case of discrepancies, plans take precedence over plant schedule. I-1 I I=1 I I=I I I=1 I I=1 I I=1 I IEI I I=1 I IEI I I=1 I I=I I I=I I I=I II= I I=1 I I I=I I I=1 I I=I I I;1 27. Contractor shall field verify existing grades, utilities and conditions, and notify the I-I I I-I I I-I I I=I I 1=1 I I=I I I=I I I=I I 1=1 I I=I I I=I I I=I I I=I I I I I I=I I I-- O Owner of any discrepancies before starting work making modifications as directed 1=1 -III-I II I I � I I III-I I III III-I I-I b the Owner. Contractor will be required to complete the work of this project =1 11` � N Tract A, Block 1 m co C4 00 c�S o - O � O rn Unit 32A U w v o � o _ � 00 � o r ✓� / \ Job No. 0714.00 \\�1�i I✓/l/ � 1 - \ Issue Date \\� v n{�J�, \ \ �Nn�{ �� / ✓ 1 Final DRB May 29; '07 Revisions June 5, 07 = — �� ` ,R 1 — > \ I / Permit July 23, '07 Revisions Sept. 17, '07 Property Line ,/�/ I\\`�! %��,� ,�1 =���a�� �f�irmu,rlq��i\�� -`r f//// I\\��y�'{ 1 2. 2 ° Native Gra P — I ° wiz 2" s Ston D ° s. � [Mlq O�!\k s� Patio 2' sR coo SB i ° se v LL Family Room Entry 5e�b t ✓ 12 Unit 31B S foil0��1 ss 0 Garage 0 10, 0 Proposed U Limit of � Roof Elevations Re: Arch. s AC AC DDisturbance '` • �, S } Garage L � eh r A o U Unit 31 A Entry o A w ° r O 2.5' wR °2 wR LL Family Room � 2 ub 12 ° 2 Plant h ul wa Scee ' Ac , Stone AC 21° Symbol Common Name Scientific Name Flower Growth Count Size V J V Patio ° N12 ° Height/Spread 0 ° • • Colorado Blue Spruce Picea pungens None 50'/25' 1 8' Ht. wR ( � 2" • 3 10'Ht. �..� 6 12'Ht 8' HT . -U . ° : Native Grasses: wR I 5B wR 2' 2 ° s � /� � ,$ Radiant Crabapple Malus spp. 'Radiant' Deep Pink 23'/18' 1 3"Cal. � 0 0 2.5' 12 1 l -N — o Quaking Aspen Populus tremuloides None 35/25 12 2'Cal. / ° 6 2 1/2'Cal. � 2" 1 3"Cal. 1 ] .r..1 0 • U S Serviceberry Amelanchier alnifolia White 6-12'/6-12' 3 5 Gal. � O 0 wR Wood's Rose Rosa woodsh Pink 4'/4' 16 5 Gal. sB Snowberry Symphoricarpos albus White w/Pink 3'/4' 15 5 Gal. UO AC Alpine Currant Ribes alpinum Insignificant 3-6/3-6 5 5 Gal. 4-1 0 D Redtwig Dogwood Cornus stolinifera'Baileyi' White 81/8' 1 7 Gal. OCopyright Fieldscape Incorporated Scale - 1" — 10'-0" r � All Rights Reserved ?— This document,and the ideas and Mixed Perennials 103 32 Ct., 12' O.C. designs incorporated herein,as an o instrument of professional service, CA is the property of Fieldscape an 1 n Plan V Incorporated and t,not n o used, p whole or in part,for any other � project without the written . '• • • Native Grass Mix to Match Existing Grasses All Disturbed Areas authorization of Ric Fields. � o Sheet rn L4 of four r� o rs, _ o 0o o11 v ry o J O � Q O, W O, - \ \ V r= rV \ \ LEVEL 3-B GRFA CALCULATION: 600 SF = r_ SI E E GE: 4 9 S F I /%// �— J r A L W LEVEL 3-B _ 600 GRFA LEVEL 3-A GRFA CALCULATION: 775 SF + V / 4 9 Q. T. y �0 GARAGE SF AFTER DEDUCTION) = 775 SF o LLJ I s Q I i� c J W \ IGARAGE-/A O — 529 GRFA � LEVEL 3-A 782 GRFA (3.) I r I / I 6 SITE COVERAGE 1" = 20'-0° 3 THIRD FLOOR GRFA �C 1" = 20'-0" \ \ LEVEL 2-13 1348 GRFA 13 LEVEL 2-13 GRFA CALCULATION: 1348 SF + (605 SF GARAGE) - 600 SF GARAGE DEDUCTION = 1353 SF I LEVEL 2-A GRFA CALCULATION: 2090 SF HOUSE 31 BASEMENT WALL DEDUCTIONS: \ I I WALL SURFACE E I II I I II I I Hasa suRFAC =1v sF 4 G 1 2 3 4 GARAGE-B WAL SU AEE WALL SURA ® / I ri°^ay / 605 GRFA A El vG ADE BELOW WALL D NALL SURFAC WALL BEL SURFACE W LLSURFA E WALLSURFACE W nyI •} AREA= SF AREA-89 5F AREA=1. A EA G4 5 AREA 3815E BELOW GRADE BELOW GRADE B LOW GRA BELOW GRADE FeF y"E[ ' B RFA=05F AREA—SF EA=OS AREA-O SF �0�'m LEVEL 2-A WALL DEDUCTIONS: 10 11 12 0 2090 GRFA TOTAL WALL AREA=3077 SF AREA BELOW GRADE=985 SIF r \\\\\\Q\ 99913077=32%BELOW GRADE , E M oQ Ia J Q in- O_ O J Q J o 6 HOUSE 31 LOWEST LEVEL WALL DEDUCTION 2 SECOND FLOOR GRFA 1" = 20'-0" 1" = 20'-0" O 1-B FA ------- - ` LEVEL 1B GRFA CALCULATION: 1335 SF 68% ABOVE GRADE = 908 SF ADJ GRFA I (SEE WALL COVERAGE CALCULATIONS) I PROPOSED GRFA UNIT A PROPOSED GRFA UNIT B LEVEL lA GRFA CALCULATION: 2091 SF LEVEL 1 = 1422 SF (ADJ.) LEVEL 1 = 908 SF (ADJ.) \ 68% ABOVE GRADE = 1422 SF ADJ GRFA LEVEL 2 = 2090 SF LEVEL 2 = 1353 SF I (SEE WALL COVERAGE CALCULATIONS) P R 0 J E C T LEVEL 3 = 782 SF LEVEL 3 = 600 SF I \ \ DRAWN BY : TOTAL GRFA UNIT A= 4294 SQ. FT. TOTAL GRFA UNIT A= 2861 SQ. FT. I \ D A T E : 05.13.13 / r TOTAL PROPOSED GRFA I / REVISIONS UNIT A TOTAL GRFA = 4294 SF / PERMIT 07.30.07 UNIT B TOTAL GRFA = 2861 SF �� / CD #1 10.23.07 TOTAL GRFA = 7155 SF I RE-ISSUE 05.13.13 TOTAL ALLOWED = 7278 SQ. FT. I 2 I \ � I I - / I I GRFA 5 GRFA CALCS 1 FIRST FLOOR GRFA 1" = 20'-0" AOO I co op J O Q n O� I Q O\ �It I- rV n W O J V O� V D Q I W S Z O J �n O Il EXTERIOR LIGHTING LEGEND 0 A - FX POST MODERNE BOLLARD B - B/K SINGLE 600 DRIVE OVER LIGHT \ �fl C - FX CUSTODE GRADINO \ \ STEP/WALL LIGHT _ \ / o D - LUMIERE WESTWOOD \ UP/DOWN LIGHT OUTDOOR WATERPROOF CHRISTMAS TREE/CONVIENENCE OUTLET, HALF SWITCHED U.O.N. ** VERIFY LIGHTING KEY W/ 1 MOST RECENT COPY OF _ I EXTERIOR LIGHTING SCHEDULE I B I EXTERIOR LIGHTING FIXTURE COUNTS: C I C A - (<18"H) 2 - NOT IN FIXTURE COUNT B - (<18"H) 1 - NOT IN FIXTURE COUNT C - (<18"H) 11 - NOT IN FIXTURE COUNT C D - (>18"H) 16 - INCLUDED IN FIXTURE COUNT — TOTAL NUMBER OF LIGHTS 18" OR HIGHER &/OR IN EXCESS D OF 40W OR 400 LUMENS: 16 d= / TOTAL NUMBER ALLOWED FOR HOUSE 31 (21,000SF LOT) _ 21 FIXTURES. Q , . D / zc— O D M ccQ cc D A OJ Q � D --nnA C� D O D i D C C C C D PROJECT : D D DRAWN BY : D A T E : 05.13.13 �X2 M IN D EVEER d=' C REVISIONS : PERMIT 07.30.07 © C CD #1 10.23.07 © RE-ISSUE 05.13.13 X MAIN & p D LE L i EXTERIOR SITE LIGHTING PLAN A0021 1 EXTERIOR SITE LIGHTING PLAN 1"=201-O" �O Lt1 140 00 ON V O PSI . Cl' J O Q :=-- O� i *— Q W O� 0 c`_'c O� Q V W S I i Z O Yo o \ E 5/8" TYPE "X" GYP. d AT CRAW LS PAC E, 2�0 TYP. � �� — — — — — — — — _M_ATCH LINE MECH. PARTY WALL � HASE �� �\ TYP. ALL MECH SPACES: PROVIDE 9 SEPARATION CFM MIN. (1 CFM / 50sf FLR AREA) ' • AIR EXCHANGER TO VENT THROUGH ELEVATOR PIT � v MECH. CHASE. in / MECHANICAL N SPACE I 002 I • CRAWL SPACE, <5' T.O. EARTH TO / UNDERSIDE OF FLR. STRUCTURE ABOVE, TYP. \II I / CRAWL L i SPACE UNFINISHED MECH. SPACE - / / 001 T.O.SLAB 8596'-0" o I / 36"X36" FIRE RATED L CRAWL SPACE, <5' T.O. EARTH TO ACCESS HATCH TO /P 1 I UNDERSIDE OF FLR. STRUCTURE °01 ABOVE, <20' FROM ALL MECH. EQUIPMENT, TYP. UNFINISHED T I U HED RA E S STORAGE G S PA 3'x4' CRAWLSPACE C E T.O.SLAB 8596'-0" ACCESS 20 MIN. -6z DOOR w/ SELF / CLOSER 11 - 3o0 1 1� 10 mss, �ETBACK LINE TYP. SLAB ON GRADE FOR '/ Q �u FLR. ABOVE 6 oC = O V J 3 = o \ Q J 1o, p PROJECT : A3o1 DRAWN BY : DATE : 05.13.13 REVISIONS : PERMIT 01.30.07 CD #1 10.23.01 RE-ISSUE 05.13.13 FLOOR PLANS Al 00 1 CRAWL SPACE - SIDE A 1/4" = 1'-0" ao / l'-O" x 15'-0" io ROOM 151 I co a E rIE 20'-6" x 17'-6" - `-' o r%4 W9 Q V J O N rifl 2 u' ✓) 1— N�ry 2�_62�� 1'-104" 41-011 2 _0411 10'-5$" ' 8 lOg 4-Ta 3=6g 3'-lg" I o i� r - �i � 2 "Sa 1 D Zb-&L---- a Ln in I cC 6 U Ln o o U I Z sz �„ 5� MECH. �� 1 z °a 2'�2 CHASE \ ° lsa D - v = U in p , 20 MIN. DOOR w/ a UNFINISHED � SELF CLOSER n°� ls3 PRHT i VOID SPACE, O MECH. B ,. , CESS, <5' 15 "o 'r' B WA \ ��� 7'-0" x 9'-6" 5/8" TYPE "X" GYP. � N I o WI 0 ® \\ TYP. ALL MECH SPACES: TYP RAWLSPACE, ,n p PROVIDE 4 CF MIN. (1 CFM / Fn im� GUEST LAUNDRY A �E� 50sf FLR AREA) AIR BED 2B k i PS EXCHANGER 10 VENT Ln 152 A31 102 THROUGH ME H. CHASE. A � "13'-0" x 7'-0" 8" CONC. WALL >1 Wz 9'-0" x 15'-0" �1i„ \ HOUR FIRE RATING �Oe MECH. z EE 11 CHASE 1 � I LL LINE 1 _j 6'-0 w s� " , CL log � I MATCH LINE 1 12 a Wo PARTY W � 112 U ELEVATOR G SEPA ION 6 36"X36" FIR RATED CRAWLSPACE CCESS = I O _ FLOOR HATCH -- r-I 3Q.0' 1os sJ 51ti HALL A @ p� 113 1 1/2" • 3�0. s 104 c' HANDRAIL @ MATCH LINE v� 20 MIN. DOOR w/ 36" AB VE GENERAL PLAN NOTES: I u? 6'- > `,�''��� - � 113 PARTY WALL % 'L SELF CLOSER STAIR OSIN 3" W9 �� _ SEPARATION i � f� �'- of TYP. - �Ln lO PROVIDE FIRE RESISTIVE TYPE "X" I o GYP ON INTERIOR WALLS AND E GUEST BED cii Q s 103 ` _ NON-COMBUSTIBLE PLYWOOD Q w9 3 A los 106 i0 5ti �u; SHEATHING ON EXTERIOR WALLS �? 105 v p1 UP _ 18-F@ 11/AE WITHIN 3T DETAIL6, WA I 10'-6" x 14'-0" 3ti titre LL POWDE ON TYP RM A CPT. W . SHEET A501 6" 103 W14 p I 1. ., BA 4'-0" x 5'-0' }7 6-614"4 7' 6Z 5/8" TYPE "X" GYP. 1 J ' 6" �j o OL LOWER LEVEL BOARD UNDER sz log \AWT.O.SUB FLR +8602'-0" 3 \ STAIRS, TYP. A310 � 1 a \ j GUEST BED TWO 106 10'- " x 1 \ IX SETBACK LINE TYP. 1 \ i LL AMILY 109 OOM A 109 wIi 111 �,•? o 25'-0" x 16-0" wii / v? %ti gee \ ° GUEST BATH �, p• ONE A O oC w I i G 108 n^ G 100 i o GUEST BED O 0 ONE A Tl RR E 109 43F' O.ST ±8 02-0 16'-0" x 11'-6" W9 1 D5 1 a. j S1 301 PROJECT : 13 �� DRAWN BY : 86 ' A602 DATE : 05.13.13 BOW +8 9'-4' REVISIONS : PERMIT 07.30.07 ,), CD #1 10.23.07 'o + -4" c�' O. RE-ISSUE 05.13.13 8 9 TO j 4595'-6" / O cA. Q FLOOR PLANS TO Z A ] 0 1 595'-6" FIRST LEVEL FLOOR PLAN - SIDE A SE CORNER FLOOR PLAN SIDE A 1 1/4.. = 1'-0" 2 1/4" = 1'-0" II II I I -II-I- - I� I� 1� II I� tf �I—II // II II II II II ENTRY- / I I II II I I II II I I II II Llv G GALZERY � /� II II II II II II II RooM� _ 62Xi N 1 II II II II 2 / 16'-0" x 17'-6" I o A6o2 I I II II I I II II I I II II D CLOSET SET - I, Q j 6 II II I II I 7 �I7I HOUR RATED D o o �oa f 36"H GUARDRAIL of i ALL w/ 5/8" TY "X"NOT TO ALLOW A501 25z PASSAGE OF 4"0 TP _ WB EACH SIDE P.Y 11 11 SPHERE, TYP. . o / 11 II II I 1 11 II 1 PANTRY I ON I I I I II I I I I I I I I II II � I I / - L - - - 1I II II I I II II I I II II a V W V) C — — MECH. STACK 1 a wl CHASE w/D 254 W � I M U IR M B c GARAGE B Q � C — — IN / 0 9'-6' x 1 '-0" 253 TILE CONC. 5x SELF LOSING 210 o \ I IN. TED D R OIL GARAGE B \ \ \ � T.O.SUB FLR +8619'-3' 1 HOUR RATED STUD I • MATCH LINE / WALL w/ 5/8" TYPE "X" I PARTY WALL HEN A ELEVATOR GWB EACH SIDE TYP. SEPARATION �\ o 206 161-011 1-911 F I ILL I • WD. MATCH LINE GENERAL PLAN NOTES: i �\ UP PARTY WALL j\ SEPARATION PROVIDE FIRE RESISTIVE TYPE "X" I 6 1 1/2" HANDRAIL @ 36" ABOVE GYP ON INTERIOR WALLS AND NON-COMBUSTIBLE PLYWOOD A501 STAIR NOSING TYP. SHEATHING ON EXTERIOR WALLS TYP. I I (EVEL WITHIN 3' OF PARTY WALL I 8 i V L SEPARATION, TYP. SEE DETAIL 6, i 201R@7 1/ "E . 2 SHEET A501. V\ \\\\ AV A `L - \\ \\ VA \\ \\ R QM 5/8" TYPE "X" GYP. BOARD UNDER STAIRS, TYP. \\ \\ \\ \\ \\\\ \\\ \\ \\ WD. o vwv 1 i 1' M/�STER 3 C LO. A A310 2 w4 14'- 36"H GUARDRAIL NOT TO ALLOW PASSAGE OF 4"0 SPHERE, TYP. \V A \\ \\ \V DI 209 SETBACK LINE Z \ \\ \\ \\ \\iA\ 4 / TYP. 4602 Q � W v o o O a O TOWN AND -MASt ER MASTER 0 J COUNTRY TC36 \ \ \\\\\ BEDROOM A BATH A O Q GAS APPLIANCE \ \\ \\\ \\\\\ 091 210 210 C \\ \\ \\ \\ 22'-0' x 15'-6" 14'-9" x 10'-2" Q �� VA \VA \ V\ VA V\ D vvv o v� v�v vv v�/'w vv vv I W3 W3 36"H GUARDRAIL NOT TO ALLOW �V\/ PASSAGE OF 4"0 A602 \\\\\ \\ \\ \\ � \\ I W3 SPHERE, TYP. \ \ \ \\ \\\V A V\ PROJECT : DRAWN B Y VA V\ \ VA O \A V A A301 \\ \\ \\ \\ \\ \ \\ DATE : 05.13.13 \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Vv v\ vv vv REVISIONS : \\ \\ PERMIT 07.30.07 �\ \\ CD #1 10.23.07 RE-ISSUE 05.13.13 FLOOR PLANS A ] 02 1 SECOND LEVEL FLOOR PLAN - SIDE A 1/4 = 1 -0 I I 1 351 \ _ SIN \ Ln � LV 111 �p / tiIN 0 353 \ N rl 0 C, �n N V ° e_4 / \ C J_ O O r-iIN ' II II II II 41-21711 2'-8" 4'-3" 41_011 C? Q _o / � R.O. N m _ � N I I II II I I II II D4 MASTER 5z" Lu C7, T.O.SUB FLR +8630'-0" _ �' II II II II O I I II II I I II II N � ; a I I II II I II W5 MASTER "o 0) p I I II B DRO M B MATCH LINE PARTY WALL a) � I I I I �EC�1 11 351 O // I 13'-3" x 17'-6" SEPARATION _ m II II II II ~� ° 36"H GUARDRAIL z SIN I I a J NOT TO ALLOW -lZ PASSAGE OF 4"0 II II II II w5 w5 I N SPHERE, TYP. II II II II 81-51' z N I I II II I I II II I � 302 N I I h 11 I M DRM A Lr) f V U w I 6 _ x17'- " I ° 0 in N 1 J 6 1n G ~ SELF �, � 3sz o I CLOSING 20 24x36 ATTIC / A R I MIN. RATED ` - BATH B DOOR--\ � / 352 r _ I 1 0 4 0 x 9 6 I _ GARAGE A �� 1 HOUR RATED � � � o =1co 1�O 6 „ '� STUD WALL w/ 301 1 0 2'-1" 3' ATILE CONC. rn 5/8" TYPE "X" 21'-6" x 23'-0" I GWB EACH SIDE � \ GARAGE A310 �� z I �P' T.O.SLAB +8632'-3" a ' I _ a o O o, L Y _ -1 5/8" TYPE "X" GYP. o I 1 x BOARD UNDER 2'.41211 3'-11i a MATCH LINE = STAIRS, TYP. � I / PARTY WALL �, CE LING H . 9'-6" Ell SEPARATION / ELEVATOR 1 HOUR RATED STUD WALL w/ 5/8" TYPE "X" GWB EACH SIDE TYP. �N / N 5z" N J 1. 4.. 11 All 6'-114" GENERAL PLAN NOTES: I �r- 1/2" H ND RAI @ 3 " ABOVE FO Zs I/AIM IN 31INU I TIP. 0 PROVIDE FIRE RESISTIVE TYPE "X" I GYP ON INTERIOR WALLS AND 4 r? WD. NTRY NON-COMBUSTIBLE PLYWOOD s, G LLERY A SHEATHING ON EXTERIOR WALLS I o A502 303 a, WITHIN 3' OF PARTY WALL �� o I R 9T@1 " E 111-0" x 9,-6" SEPARATION, TYP. SEE DETAIL 6, I 0 W . 10 @ -1/4" EA. D. TIL SHEET A501 D T.0 3UB FL +8632' 0" VAULTED SPACE 3 w3 m) m I iv I <16' AFF I O -- 2'-612" 3'-1" 3'-1" 3'-1" 31- 3'-1" 3'-1" 3'-1" 15'-6" �. R.O. R.O. R.0. O. R.O. O. 711 551z. z R.O. L512 1"1 55 1 � 27'-51" ` act - W 3 SETBACK LINE v OJ TYP. O O A310 / � O O � J Q Q I PROJECT : DRAWN BY : D A T E : 05.13.13 REVISIONS : PERMIT 07.30.07 CD #1 10.23.07 RE-ISSUE 05.13.13 1 A301 FLOOR PLANS A ] 03 THIRD LEVEL FLOOR PLAN - SIDE A 1 A 1/4" = 1'-0" �\ 3:12 ROOF PITCH RIDGE ROOF RIDGE T.O.SHEATHING +8629'-3" DECK i \ ° o , / m — �o 0o o, \ \ MAX. ALLOWED +8635'-0" L --- --------------- ---------------------------------- D I I V n / \ RIDGE i SNOW GUARDS CLIPPED 3" ROUND DOWNSPOUT _, o \ 3:12 ROOF PITCH TO STANDING SEAM (DS), TYP. Q a T.O.SHEATHING +8641'-0" ROOF AS NECESSARY, / \ RIDGE VERIFY LOCATIONS Q o 6 HALF-ROUND GU ER I MAX. ALLOWED +8641 -2 W/ HEAT TRACE, P. \ i STANDINGS M ROOF \ WITH 16" IDE PANELS, ,. , o TYP. v a cc iiiiiji V EAVE. i c T.O.SHEATHING +8626'- CRICKET 3:12 ROOF PITCH i W x 0 1 EAVE F- -------- i z \ MAX. ALLOWED +8629'-Cl' \ I I o �\ 3:12 ROOF PITCH 4LRIDGE 3:12 ROOF PITCH T.O.SHEATHING +8 5'-3" o FLAT ROOF EAVE RIDGE r. 3:12 ROOF PITCH I I I i T.O.SHEATHING +8626'-0" ^ MAX. ALLOWED +8646'- EAVE v 2 MAX. ALLOWED +8627'-0" /j_ ' OVER-FRAMING '' _ V � � � I 3:12 ROOF PITCH I 0 \ - + MATCH LINE --�------- ------- ---- �I -.ARTY ALL SEPARA ION RIDGE T.O. EATHIN 8'-4 1/ R DGE MAX. ALLOWABLE +86 8'-6" 2 ` AVE u F.O.SHEATHING +8641'-6" 1 =AVE R ISIONS PENDING AX. ALLOWED +8653' V 0 � V i \ • EAVE i -- T.O.SHE_A_THING +8623'- 1A, p CRICKET I - I V V-p E 2:12 ROOF PITCH EA - -- — " — — _ — — E K M O�NTAI N \ \ GENERAL ROOF PLAN NOTES: MAX. ALLOWED +8623'-0' � — — — _ _ _ _ � � i AND DOWN 5 5:12 HAVE HEAT E 00 P ABOVE GUTTER S I Q�PAP � � .�•1 - � \ � i TO UNDERSIDE OF SNOW GUARDS _ IDGE \ V Zj ` T.O.SHEATHING +8626'-4 1/2" - _ _ Q� RIDGE t` 1 EAVE ° \ \ f ` MAX ALLOWABLE +8629'-0" \ \ ' T.O.SHEATHING +8639'-10" I \ �G� V v VE MA ALLOWED +8645'-0" ZSETBACK LINE o TYP. Oct• �� Z c� 0. ° V � P / V Q Lu o RIDGE 'L G, �\ T.O.SHEATHING +862 '-10" � Ov / O x � �'G� RIDGE O J MAX. ALLOWED +8635'-6" 0<v / y O c i �3 , P R O 1 ECT : \ DRAWN BY : ci DATE : 05.13.13 / \ / REVISIONS : / PERMIT 07.30.07 CD #1 10.23.07 P RE-ISSUE 05.13.13 0 v ;X� y FLOOR PLANS Al 04 1 ROOF PLAN - SIDE A 1/4" = 1'-0" 36" STONE WALL o n �o 0o o V n J O • Q � � O Q O, W C, v ry 0 i J V O • CC V y C Q 42'-1" x Lu i z 111 O 5z 71" 71i a J 4 4 tr 4'-8z" 7' 1.. 7'_11" -0" 16'-6" u 2 J /L. O. o OW \ +48" AF W 1S 5/8" TYPE "X" GylP. +36" AF 1110 11.1 \ BOARD UNDER \ STAIRS, TYP. 502 \ in _y LL STO. B 36"H STONE WALL. NO OPEN ti 155 _ SPACE TO ALLOW PASSAGE OF o 36"X36" FIRE RATED 3'-6" x 11'-6' _ 4" DIA. SPHERE TYP. - CRAWLSPACE ACCESS \ FLOOR HATCH 1 CRAWLSPACE<24" HT. RACE A6 2 RE: STRUCT T. .SLAB 86 -6' co \ ,n o 1 1/2" HANDRAIL @ 36" iv _ N ABOVE STAIR NOSING ~in N TYP. �^J L co S -112 r 4 N 6 5'-44„ , = 9'-114" 156 D2 w�2 31.8$" v 6'-8" 2'-7z.. SETBACK LINE 1 '^ TYP. fn 9$" SZ., 1' O$" 155 981 \\ -�N I 6 = L, - \ Hw a- "' LOWER LEVEL w i "' T.O.SUB FLR +8603'-0" ` O � ls� _ 12'-0" 2 _7211 102 22'-01" - BPI o / GUEST 2 / BED 3B -LI 1111111111-1 156 L.L FAMI Y 0o 11'-0" x 15'-0" io ROOM ° 151 a = 20'-6" x 1 '-6" - - - - - - - - - - - - - - - - - - - W9 1� o O7y) of rl N i N I D\? 000 / io ~Ln 2 61 1'-103i 2 03 2 10'-53" s? 8'-10$" 4�_I4n -3r�$,n 31.11 / 2 4 4'-0" 4 8 I (y tiIN ^ I 1" 1 �p -------_-------- 4 in Ln 2 6`,S4 U Ln 52 y„ 5j MECH. O 1 z I I Q , . 1 2`'Iz CHASE °O O° ls4 0 O 20 MIN. DOOR w/ I n^ G Q UNFINISHED cC 1 " SELF CLOSER v J "� +42 PRHT i \ VOID SPACE, O MEC . B = Q O '-' '^ B N/A \ CESS, <5'F 15 = "o I ~ 7'-0" x 9'-6" 5/8" TYPE "X" GYP. � r'4 I O v i \ \ SPACES: TYP. ALL MEC O AT CRAWLSPACE, N O Q J I�i TYP Q L? p � PROVIDE 4 CFA MIN. (1 CFM / Fn w G JEST iA� o LL 50sf FLR AREA) AIR 1 m., i LAUNDRY A "co EXCHANGER P EXCHANGER O VENT 102 THROUGH ME H. CHASE. I � 152 A31 �, � � l 13'-0" x 7'-0" 8" CONC. WALL >1 Wz 9'-0" x 15'-0" 11 '111„ y�� ` HOUR FIRE RATING MECH. AAA E 1, CHASE 0 1 Lu s? 6'-0" I LL LINE CL 102 �= MATCH LINE 12 1 112 o PARTY W U I ELEVATOR O ° SEPA ION i '� 6i CRAW6LSPACE RATED CCESS I n - _ 1 o pia FLOOR HATCH � �� ° LL 105 s? \% HALL A 6 pf 113 1 1/2" \ l04 / \ HANDRAIL @ MATCH LINE 6\, >e �J� 20 MIN. DOOR w/ 113 36" AB VE PARTY WALL GENERAL PLAN NOTES: I P R 0 J E C T . �, 3 ti SELF CLOSER STAIR OSIN W 9 SEPARATION � h � TYP. lO PROVIDE FIRE RESISTIVE TYPE "X" DRAWN B Y GYP ON INTERIOR WALLS AND I D A T E 05.13.13 cp E GUEST BED 2 `r? 103 �� _ NON-COMBUSTIBLE PLYWOOD 7 w9 3 A los / 1 06 to "u; 20 @ 1/ "E SHEATHING ON EXTERIOR WALLS ' R E V I S I 0 N S 105 , p? UP 18 @ 1" A. WITHIN 3' OF PARTY WALL I 10'-6" x 14'-0" 1" tia LL POWDE SEPARATION, TYP. SEE DETAIL 6, PERMIT 07.30.01 0 � �� RM A CPT. W SHEET A501 � CD #1 10.23.07 0 wi4 1�` `9; �- 103 �/ BA 4'-0" x 5'-0 I RE-ISSUE 05.13.13 Q, 6'-64" `roJ 6„ 7'-61" 5/8" TYPE "X" GYP. 1 o LOWER LEVEL BOARD UNDER e T.O.SUB FLR +8602'-0" 3 STAIRS, TYP. 10 0 , A310 1 0 -0� G TWO A° o FLOOR PLANS i--� 106 1�` \ A ] 05 1 A301 FIRST LEVEL FLOOR PLAN - SIDE B 1' 1/4" = 1'-0" r� - 140 0o o1 v ry V r_ J O Q r• W O, O / \ CC V Q /� V W S J / 5/8" TYPE "X" GYP. \ BOARD UNDER w w STAIRS, TYP. \ SETBACK LINE • TYP. / °�° N N \ 1 \ —_ — / �j�\ o s o II I II II Ir II 5 I I I I I I-'rf I I�I 7T 11° EA. \ • I� II II II II 8R 6° EA . DI \ It- r- t1 -II- t1 _t1 1 W/WOODCA ENTRY / II II II II II / I I 1 II I I 11 I I II II LIVING I I II ROOM B - - - - - - 1 II II I I II 11 259 r _ x / 16'-0" x 17'-6" / A602 II II II II II II ' I I- U- -I--I -_I I-_I� I-1 -I I�I � D - / I I I I I I I I I I T-f �I 77 I 36"H GUARDRAIL 6 1 HOUR RATED D I / NOT TO ALLOW A501 zsz WALL w/ 5/8" TY "X" 1( / PASSAGE OF 4"0 TYP WB EACH SIDE P. SPHERE, TYP. II II I I I II / - - - PANTRY II II II II II II II II II II II II � - - - - � � '- - - - u U Li J I C MECH. STACK 1 I wi CHASE w/o 254 / MU RO MB GARAGE B P C — — IN / Q e 9'-6' x 11'-0" 1 TILE CONC. 253 / \ 253 27'-0" x 22'-6" / I ° \ I Q. Q W cc OIL GARAGE B ^^ O \ T.O.SUB FLR +8619'-3' I G 1 HOUR RATED STUD MATCH LINE WALL w/ 5/8" TYPE "X" I O O PARTY WALL / HEN A ELEVATOR GWB EACH SIDE TYP. O SEPARATION �\ ° ° 206 I O Q = -0 16 -9 I _ Q J � WD. MATCH LINE GENERAL PLAN NOTES: i UP PARTY WALL I 0 / \ SEPARATION Ol PROVIDE FIRE RESISTIVE TYPE "X" 6 GYP ON INTERIOR WALLS AND 1 1/2" HANDRAIL @ 36" ABOVE NON-COMBUSTIBLE PLYWOOD A501 STAIR NOSING TYP. SHEATHING ON EXTERIOR WALLS I TYP. I I G VEL WITHIN 3' OF PARTY WALL 8 // V L 2 SEPARATION, TYP. SEE DETAIL 6, i L SHEET A 1. 201@7 1/ E - S 50 / 18 @ 1" A. A310 W i / 5/8" TYPE "X" GYP. I "0 1 --- -- BOARD UNDER \\ \ \\ \\ \ \\ 25 - STAIRS, TYP. P R 0 J E C T \\ \\ \\ \\ \\ \\ \\ \\ \\ m D R A W N B Y 207 1 / DATE : 05.13.13 MP,STER A 3 0 REVISIONS : // 14'- ' x 7'-6" \ PERMIT 07.30.07 36"H GUARDRAIL \\ \ \\ \ \\ \\ / / ` CD #1 10.23.07 NOT TO ALLOW \ \\ \\\\ \ \\\ \\ \\\ \\\\ \\ // / RE-ISSUE 05.13.13 PASSAGE OF 4"0 SPHERE, TYP. \V A \\ \\ \\ DI 209 SETBACK LINE TYP. 1 FLOOR PLANS Al 06 A301 1 SECOND LEVEL FLOOR PLAN - SIDE B 1/4" = 1'-0" r— - r_n . o Lin �o 0o ON `' o e_4 V n J O • Q � � O � Q O= W C% v ry 0 oc V 7'-51211 16'-6" \ 28'-10411 _LLJ 51211 o 2'-6" 2'-7'1 1'-1 " 2'-7" 1'-101211 21 711 21.611 6'-5211 5'-11$11 21.711 41.711 21 711 61.311 a J SETBACK LI E / R.O. R.O. R.O. R.O. R.O. % TYP. \ � o w w5 0 1 5/8" TYPE "X" GYP. w5 \ rn BOARD UNDER STAIRS, TYP. \ IN Ln 0 / D N n \ `N 0 1 1/2" HANDRAIL @ 36"_j / ABOVE STAIR NOSING MASTER _ rlj TYP. CLOSET B N Ln 353 / Sao 1 • / 351 \ _ -IN QD / w IN Lr)SIN 353. / N i _ / O • IN 4 -2 ' 2'-8° 4'-3° N II 1 1 II II 12 m `" MASTER 512 ° T.O.SUB FLR +8630'-0" ❑ �> / I I II II I I II II /' I I II II I I II II I I I II II I I II II N / II II ws MASTER MATCH LINE "'N - I BEDROOM B / o o, o I I EC I II - - - /' °C 351 PARTY WALL - Q 13'-3" x 17'-6" '' SEPARATION I m r 11 -Ln� z - 36"H GUARDRAIL 1 NOT TO ALLOW I 2'-5g" 3'-1211 N PASSAGE OF 4"0 ws ws N / SPHERE, TYP. II II / - 8'-511 3, 2 3oz /- N I II II II N I M DRM A IN N `n U I ° - TR I 61_ 11 x 17'-0" ° I O O N ti 5 LF C OSI G 20 MIN. RATED 24x36 ATTIC - BATH B DOOR- F3 52 I co 4'-0" x 9'-6" i 301 = 1 HOUR RATED GARAGE A roi Ul" t rl O 6" 1 STUD WALL w/ I 301 i I _0 2' 1" 3' TILE CONC. ^) 5/8" TYPE "X" \ 21'-6" x 23'-0" -' r�" A310 i GWB EACH SIDE \ \ 2 TYP GARAGE T.O.SLAB +8632'-3" QW z I � a o / 01 Y = 5/8" TYPE "X" GYP. o I vp BOARD UNDER 1i x a I— J 1 x - 2 412 3'-1- Q O MATCH LINE STAIRS, TYP. z O � CL_ v ' � N 11 PARTY WALL �, CE LING H . 9'-6" I O J p ELEVATOR It — SEPARATION / _ 1 HOUR RATED STUD WALL w/ 5/8" TYPE O Q "X" GWB EACH SIDE TYP. \ 51" o 5� " N I I 1'- 4" -72" 6'-11411 GENERAL PLAN NOTES: i �^ 1/2" H A.N DRAI L @ 3 BOVE r;� O Ol PROVIDE FIRE RESISTIVE TYPE "X" I j, GYP ON INTERIOR WALLS AND r? WEI. ENTRY NON-COMBUSTIBLE PLYWOOD GALLERY i SHEATHING ON EXTERIOR WALLS 0 303 a, WITHIN 3' OF PARTY WALL I R 9T@11" E 11' 0" x 9'- 11 SEPARATION, TYP. SEE DETAIL 6, i u? T. 8 2 0' W 10 @ -1/ " E WD. TIL SHEET A501 D T.O."UB FLR +86-12'-0" --- VAULTED SPACE 3 w3 w3 w3 rn I I <16' AFF Q N 1 PROJECT : ate° DRAWN BY : 21-612" 3'-1" 3'-1" 3'-1" 31- 11 3'-1" 3'-1" 3'-1" 15'-6" D A T E : 05.13.13 �. R.O. R.O. R.O. R.O. R.O. R.O. R.O. 7„ 1 5111 5x11 �571"' 5111 51 2 z REVISIONS : 27'-52" \ PERMIT 07.30.07 CD #1 10.23.07 42'-11 " RE-ISSUE 05.13.13 3 SETBACK LINE TYP. A310 / 1 FLOOR PLANS A301 A ] 07 THIRD LEVEL FLOOR PLAN - SIDE B 1 B 1/4" = 1'-0" ° \ o Nn / 1 — NO co c3r, V r- 4— O / o .— LLJ N 1 0 O \/ o v o \ Q ° W \ / EAVE 1 T.O.SHEATHING +8639'-0" W / EAVE \ / eo MAX. ALLOWED +8639'-0" 1 ° \ / \ / r 3:12 ROOF PITCH 1 / \ op a 1 Fq i 1 \ 3:12 ROOF PITCH 3:12 RO F PITH CRICKET 3:12 ROOF PITCH 3 - X 3:12 ROOF PITCH RIDGE ROOF ' ' - �' T.O.SHEATHING +8629'-3" DECK m OIL RIDGE MAX. ALLOWED +8635'-0" i - DS /' \ SNOW GUARDS CLIPPED 3" ROUND DOWNSPOUT \ 3:12 ROOF PITCH T.O.SHEATHING +8641D' \ i ROOF AS NECESSARY, \ RIDGE VERIFY LOCATIONS 6" HALF-ROUND GU ER i MAX. ALLOWED +8641'-2" i W/ HEAT TRACE, P. i STANDINGS M ROOF WITH 16" IDE PANELS, � TYP. 1_ 3 EAVE T.O.SHEATHING +8626'- CRICKET 3:12 ROOF PITCH EAVE G F ---- -- O MAX. ALLOWED +8629'-0'1, i 3:12 ROOF PITCH RIDGE 3:12 ROOF PITCH T.O.SHEATHING +8 5'-3" FLAT ROOF EAVE 3:12 ROOF PITCH I RIDGE T.O.SHEATHING +8626'-0" MAX. ALLOWED +8646'- i I EAVE v _ i Q MAX. ALLOWED +8627'-0" Z Q OVER-FRAMING ; 3:12 ROOF PITCH MATCH LINE V O - - - - - - - - - - - - - - - 0 - ---f- ------- -- � ARTY ALL Q O `� SEPAR ION V � Do RIDGE O O J T.O. EATHIN -1- 8'-41/ R D GE Q j O MAX. ALLOWABLE +86 8'-6" ' i AVE O O.SHEATHING +8641'-6" AVE AX. ALLOWED +8653'-0" R VISIONS PENDING EAVE / \ T.O.SHEATHING +8623'- iE►/►/_�E CRICKET \ \ I VV EK MOONTAI,N EA 2:12 ROOF PITCH — — — GENERAL ROOF PLAN NOTES: i MAX. ALLOWED +8623'-0' — — — — — _ _ 5 5:12 1. ALL GUTTERS AND DOWN SPOUTS TO I HAVE HEAT TRACE, LOOP ABOVE GUTTERS TO UNDERSIDE OF SNOW GUARDS i H� _ _ P � �GE 1 ` - - ----------------------- P R 0 E C T ` — � �, � � �� , � � � DRAWN BY : T.O.SHEATHING +8626 -4 1/2 1 t / \ \ Q` RIDGE 1 f' 1 EAVE o 1 D A T E : 05.13.13 MAX ALLOWABLE +8629'-0" y' \ T.O.SHEATHING +8639'-10" d I VE A MAX. ALLOWED +8645'-0" R E V I S 1 0 N S PERMIT 07.30.07 p 1 ` CD #1 10.23.07 4'-0" RE-ISSUE 05.13.13 i o SETBACK LINE TYP. AAJ P 6 FLOOR PLANS A301 A ] 08 1 ROOF PLAN - SIDE B 1/4" = 1'-0" O co crl /� I V r• i J O • Q W O� V � N N i O 5'-2 4 - 8 cC I v I � D Q V W S n I L Z O J i W O o / rIN / E I ZOO p3 \\ \ - _ _ �_MATCH LINE PARTY WALL \\ I SEPARATION ELEVATOR PIT I MECHANICAL A - N SPACE oo I 002 A / CRAWL SPACE 001 A o I TO ABOVE i � A A 1 eS�QP A I z � 1 i 1 0 -- 1 SETBACK LINE TYP. V 0 QW O 3� M o Q x °C V � GENERAL ELECTICAL NOTES: O � 1. TYPICAL COLOR OF DECORA: WHITE - DRYWALL LOCATIONS BLACK- STONE LOCATIONS, VFY. a J 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2003 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED �o' O WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH INTERIOR ELEVATIONS ELECTRICAL PLAN NOTES: Ol PROVIDE GFCI PROTECTED UNDER CABINET PLUG MOLDS AS NECESSARY PROJECT : LIGHTING SYMBOLS A301 ' D R A W N B Y s DATE : 05.13.13 OA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET SMOKE DETECTOR ADJUSTABLE DOWNLIGHT COMBO. DATA/TELEPHONE OUTLET DUPLEX OUTLET +18" U.O.N. 1 / \ R E V I S 1 0 N S 0_+ RECESSED CAN LIGHT: �`-- ADJ ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET / PERMIT 01.30.01 GROUND FAULT DUPLEX OUTLET, ' CD #1 10.23.01 sAA SURFACE MOUNTED LIGHT FIXTURE SWITCH +42" U.O.N. / RE-ISSUE 05.13.13 DECORATIVE LIGHT FIXTURE S 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED MULTIPLE SWITCH +18" U.O.N. o PENDANT LIGHT 4 DUPLEX FLOOR OUTLET $p DIMMER DUPLEX FLOOR OUTLET, HALF SWITCHED © RECESSED LENSED SHOWER LIGHT VARIABLE rM $V N® INFLOOR DATA AND QUAD PAR-20 MULTIPLE RECESSED ADJUSTABLE $T TIMER POWER OUTLET SPOT LIGHT BY EUROFASE, TBD N® INFLOOR DATA AND DUPLEX SWITCH IN JAMB POWER OUTLET / 24" HALOGEN UNDER CABINET LIGHT i KEY HOMEWORKS KEY PAD T NEW HOSE BIB EXTERIOR WALL SCONCE O1 HOMEWORKS CIRCUIT DESIGNATION / ELEC. PLANS A O NEW JUNCTION BOX ©A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN O NEW NATURAL GAS LINE / A110 ELECTRICAL PLAN CRAWL SPACE - SIDE A 1 1/4" = 1'-O" BED 3B y a BA 3B u 1 56 1 57 y L FAMILY / v ROOM B, �o �n / 151 co 40 00 0� v r.i / Pal OV a 0 W O� / KEY _�_ J I +66'IAFF,------------ d- Po �-��-----------=VFY J- 0 W ON O 1 I •� CC A- 4 MECH. KE CHASE vo(p 4 �' Lu i z +42" / \ a J G ST PRHT MECH. B W BA 2B WA PL 15 L BED GUEST 1 � UNDRY A 152 A310 P 102 \ MECH. \ / CHASE 220V - - - - - - Q / KEY ° LL LINE KEY AL C i MATCH LINE - - J 1 � - I • PARTY WALL i SEPARATION \ o GUEST BATH 3A - 104 LL KEY - - - - '-6" x 1 HALL A I -� 113 TO LOW • ADJ MATCH LINE PARTY WALL I ' lk SEPARATION i � A I GUESTABED 105 i I LL PO E i A 103 I GU BATH T A �F1 1 1 o LOWE LEVEL T.O.S B FLR +8602'-0" 3 A310 GUEST BED \ TWO A OO 106 \ - - - - - - Q \ , A Z 1 LL 'A MILY \ /-ROOM A / O � 111 o oQ � W ° GUEST BATH ONE A O 108 , M c 0 O / J o�o ADf GENERAL ELECTICAL NOTES: ,�� �� CL_ v O 1. TYPICAL COLOR OF DECORA: WHITE - DRYWALL LOCATIONS Q BLACK- STONE LOCATIONS, VFY. GUEST BED Q �� CL_ ONE A 2. POWER AND LIGHTING DISTRIBUTION TERRACEjk 109 TO FOLLOW REQUIREMENTS PER 2003 T.O.STONE ±8602-0" IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH INTERIOR ELEVATIONS ELECTRICAL PLAN NOTES: Ol PROVIDE GFCI PROTECTED UNDER 1 CABINET PLUG MOLDS AS NECESSARY A301 PROJECT : LIGHTING SYMBOLS zz % 13 D R A W N B Y A602 DATE 05.13.13 OA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET Os SMOKE DE ECT \ ADJUSTABLE DOWNLIGHT COMBO. DATA/TELEPHONE OUTLET DUPLEX OUT ET + 8" U.O.N. R E V I S I O N S 0♦ RECESSED CAN LIGHT: ADS ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET / PERMIT 07.30.01 GROUND FAULT PL OUTLET, ' CD #1 10.23.07 =AA SURFACE MOUNTED LIGHT FIXTURE SWITCH +42" U.O.N. / RE-ISSUE 05.13.13 3-WAY SWITCH DUPLEX OUTLET, HA L S TCHED ' DECORATIVE LIGHT FIXTURES MULTIPLE SWITCH +18" U.O.N. � G PENDANT LIGHT 4 O DUPLEX FLOOR OUTLET DIMMER D ❑A DUPLEX FLOOR OUTLET, H LF S ITCHED © RECESSED LENSED SHOWER LIGHT VARIABLE / $V 14 INFLOOR DATA AND QUAD SURFACE MOUNTED LIGHT $T POWER OUTLET j T INFLOOR DATA AND DUPLEX / SWITCH IN JAMB F147@ POWER OUTLET 24" HALOGEN UNDER CABINET LIGHT i KEY HOMEWORKS KEY PAD � NEW HOSE BIB ' EXTERIOR WALL SCONCE 01 HOMEWORKS CIRCUIT DESIGNATION ELEC. PLANS �A O NEW JUNCTION BOX , =A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN O NEW NATURAL GAS LINE A ] I I 1 FIRST LEVEL ELECTRICAL PLAN - SIDE A 1/4" = l'-0" El- / II II II II II II v GALLERY B / II II II II II II IV G II II II II II II ROO KEY 251 /� 1 I I II II I I II II I I II II 259, � E:) EN RY �- / A602 II II II II II II o o CLO ET B Q } GD 25 I 6\ II T T1 II II T( �I�I // DW I _ ' / KITCHEN B o o Q °l / II II II II A501 I I II II I I II II I I II II / I 258 I `' / TYP. ON o ,/ II II II II II II II II II / I _ I I II II I I I I II I I II I I / I — / L _ _ KEY 220 EY C — — MECH. a o 44 CHASE Fc / C I NG MOUNT R ILING MOUNTED FOR u O / / UDRO M B J[g AGE DOOR O ER RAGE DOOR OPENE \ Y o 254 GARAGE IN / ` ® 253 ADJ I o I O i� O DJ A I \ ADJ MATCH LINE \ I D HEN PARTY WALL SEPARATION �\ , o ° 206 611 L o, \ I MATCH LINE i PARTY WALL /\ DJ �\ i \ \ SEPARATION I 1 1/2" HANDRAIL @ 36" ABOVE i A501 / w ^ STAIR NOSING TYP. TYP. / ADJ / \ A I /A 2 — — — A310 i LIVING EY ROOM A — \\ \\ \\ \\ \\\\ \\ 205 \ \\ \ 1 RM. A OWDER w 207 MASTER 1 C LO. A A310 DI\\ \ Z - - - - - - - \ 4 �l \ _ A602 act , . \ � o v ADJ v o GENERAL ELECTICAL NOTES: MASTER V A BEDROOM A ADJ BATH A O Q 1. TYPICAL COLOR OF DECORA: \ \\ \ � Q WHITE - DRYWALL LOCATIONS \ / \\ \\\ \\ \\\ 09 210 C BLACK- STONE LOCATIONS, VFY. 2. POWER AND LIGHTING DISTRIBUTION \\\ \\\\\ \\\ \\\\\\ \ o TO FOLLOW REQUIREMENTS PER 2003 I RC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN VA V\ >\/ 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR \\ \\ \ \ \ \\\ \ TVs WITH INTERIOR ELEVATIONS \\\ \ \\\ \\ \\\ \\\\ \ I / ELECTRICAL PLAN NOTES: 1 PROVIDE GFCI PROTECTED UNDER CABINET PLUG MOLDS AS NECESSARY PROJECT : \ \ \\ \\\ \\\\\\\\ \\\ \\\ A301 LIGHTING SYMBOLS \ \ \ \ D R A W N B Y O RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET OO SMOKE DETECTOR \ \\\\\ \\\ \\ \\ \\ DATE 05.13.13 A ADJUSTABLE DOWNLIGHT COMBO. DATA/TELEPHONE OUTLET DUPLEX OUTLET +18" U.O.N. \\ \\ \\ RECESSED CAN LIGHT: \\ \\ \\ \\ REVISIONS c_+J ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET \\\ \\\\\ �j PERMIT 07.30.07 s SURFACE MOUNTED LIGHT FIXTURE SWITCH GROUND FAULT DUPLEX OUTLET, \\ CD #1 10.23.07 AA +42" U.O.N. RE-ISSUE 05.13.13 DECORATIVE LIGHT FIXTURE �3 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED� +18" U.O.N. MULTIPLE SWITCH / 4 DUPLEX FLOOR OUTLET ' o PENDANT LIGHT � DIMMER / © RECESSED LENSED SHOWER LIGHT D ❑D DUPLEX FLOOR OUTLET, HALF SWITCHED $V VARIABLE N@ INFLOOR DATA AND QUAD / TIMER POWER OUTLET SURFACE MOUNTED LIGHT T INFLOOR DATA AND DUPLEX SWITCH IN JAMB N® POWER OUTLET 24" HALOGEN UNDER CABINET LIGHT i FK_E_Yl HOMEWORKS KEY PAD HB Frtl NEW HOSE BIB � EXTERIOR WALL SCONCE 01 HOMEWORKS CIRCUIT DESIGNATION / ELEC. PLANS A O NEW JUNCTION BOX =A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN 0 NEW NATURAL GAS LINE / A112 1 SECOND LEVEL ELECTRICAL PLAN - SIDE A 1/4 = 1 -0 I � 351 / 353 K Y v co \ d / - - - I J o Q /' I I II II I I II II / II II II II a / I I II II I I II II ' I I II II I I II II ' / I I II II I I II II I � Lu a / I I II II I I II II MASTER B DRO M B �EC� MATCH LINE Q 351 PARTY WALL SEPARATION = I I II II I II II � o I I II II I I II II I J II II II II II II A a _� I I II II I I II II � � o II II II II I 302 I I II II I I II II � v MUDRM A 02 o KEY I A CEILING MOUNTED FOR / GARAGE DOOR OPENER i 7L1 5 o I BATH 352 I (lip � o I GARAGE A 0 +44 ` / \ 301 i _ GARAGE I A310 44 2 KEY r�-Zj T.O.SLAB +8632'-3" +44 I O i • � I / — — — — — LIBRARY CEI ING MODUNTED�FOR A 2 04 GAR GE DOOR OPENER MATCH LINE ��/ a � PARTY WALL SEPARATION \ / I r---- ---- KEY I I 352 ENTRY I 4 w GALLERY A A502 I LIBRARY 3 03 T.O.SUB FLR +8626'-0" I ---- w I VAULTED SPACE I I <16' AFF I 1 1 V QW - - - - - V � 3 GENERAL ELECTICAL NOTES: A310 ' O ~ Ov 1. TYPICAL COLOR OF DECORA: WHITE - DRYWALL LOCATIONS / C BLACK- STONE LOCATIONS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2003 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED O WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH INTERIOR ELEVATIONS ELECTRICAL PLAN NOTES: Ol PROVIDE GFCI PROTECTED UNDER CABINET PLUG MOLDS AS NECESSARY PROJECT : LIGHTING SYMBOLS D R A W N B Y OA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET OO SMOKE DETECTOR D A T E : 05.13.13 ADJUSTABLE DOWNLIGHT COMBO. DATNTELEPHONE OUTLET DUPLEX OUTLET +18" U.O.N. R E V I S I O N S O♦ RECESSED CAN LIGHT: ADJ ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET PERMIT 07.30.07 GROUND FAULT DUPLEX OUTLET, CD #1 10.23.07 =AA SURFACE MOUNTED LIGHT FIXTURE SWITCH +42" U.O.N. RE-ISSUE 05.13.13 DECORATIVE LIGHT FIXTURE $3 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED +18" U.O.N. MULTIPLE SWITCH 1 C PENDANT LIGHT 4 O DUPLEX FLOOR OUTLET A301 p DIMMER DUPLEX FLOOR OUTLET, HALF SWITCHED © RECESSED LENSED SHOWER LIGHT VARIABLE $V N® INFLOOR DATA AND QUAD SURFACE MOUNTED LIGHT $T TIMER POWER OUTLET INFLOOR DATA AND DUPLEX / SWITCH IN JAMB 47 POWER OUTLET / 24" HALOGEN UNDER CABINET LIGHT i KEY HOMEWORKS KEY PAD T NEW HOSE BIB � EXTERIOR WALL SCONCE 01 HMEWRKIRUIT DESIGNATION ELEC. PLANS �A O OS CC SG OO NEW JUNCTION BOX =A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN 4 NEW NATURAL GAS LINE / Al 13 1 THIRD LEVEL ELECTRICAL PLAN - SIDE A 1/4" = 1'-0" LIGHTING SYMBOLS OA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET OO SMOKE DETECTOR `^ �o �n ADJUSTABLE DOWNLIGHT co a COMBO. DATNTELEPHONE OUTLET DUPLEX OUTLET +18" U.O.N. v r-4 c_* RECESSED CAN LIGHT: 0 v ADJ ADJUSTABLE WOR SLOPED SPOT TRIM 2 RG6 COAXIAL QUAD OUTLET Q GROUND FAULT DUPLEX OUTLET, Q a =AA SURFACE MOUNTED LIGHT FIXTURE $ SWITCH +42" U.O.N. 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED DECORATIVE LIGHT FIXTURE $3 +18" U.O.N. Lu N MULTIPLE SWITCH c PENDANT LIGHT 4 DUPLEX FLOOR OUTLET o DIMMER r- D DUPLEX FLOOR OUTLET, HALF SWITCHED ,. , J O� RECESSED LENSED SHOWER LIGHT VARIABLE V V N® INFLOOR DATA AND QUAD °C SURFACE MOUNTED LIGHT TIMER POWER OUTLET Q INFLOOR DATA AND DUPLEX `, LJ SWITCH IN JAMB N® POWER OUTLET i Z 24" HALOGEN UNDER CABINET LIGHT Y HOMEWORKS KEY PAD T KE NEW HOSE BIB p o EXTERIOR WALL SCONCE 01 HOMEWORKS CIRCUIT DESIGNATION , A O NEW JUNCTION BOX =A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN O NEW NATURAL GAS LINE o GENERAL ELECTICAL NOTES: ' 1. TYPICAL COLOR OF DECORA: / \ WHITE - DRYWALL LOCATIONS \ BLACK - STONE LOCATIONS, VFY. 2. POWER AND LIGHTING DISTRIBUTION \ TO FOLLOW REQUIREMENTS PER 2003 IRC Nl 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4 4. VERIFY ALL FLOOR OUTLET LOCATIONS SIM. \ WITH FINAL FURNITURE LAYOUTS / 5. VERIFY HEIGHTS OF RECEPTACLES FOR A LL STO. B \ TVs WITH INTERIOR ELEVATIONS 155 ELECTRICAL PLAN NOTES: / ` O1 PROVIDE GFCI PROTECTED UNDER / 13 CABINET PLUG MOLDS AS NECESSARY \ TERRACE A602 D T.0.SLAB +8602'-6" \ Lu A- 4 w / O \ KEY `\ / KEY \ / KE \ GUEST GUEST \ BED 3B BA 3B / 156 157 D L FAMILY / RO M - - - - - - - - - - - - - - - - - - - P / ° I I / KEY 1 l��❑�1 VFY.+ I A- 4 MECH. $�O O \ 0 KE Q Lu o CHASE ��� E� +42" MECFI. B G ST PRHT I v \ I � BA B WA 15 p I O Q O 1 / � � � I � � V o P \ I ° J � � a Q J GUEST L 1 L� UN A BED 2B A310 /' P 102 I 152 � MECH. CHASE 220V \ - - - - - - O � I I Q KEY L ° LL LINE KEY A CL MATCH LINE 1 I 1 PARTY WALL SEPARATION 1 I � o GUEST BATH - - - - - - - - - - - - - - - - - 3A 104 LL KEY '-6" x 12' HALL A I -� 113 TO LO W MATCH LINE AoJ PARTY WALL I PROJECT SEPARATION D R A W N B Y -c A I DATE : 05.13.13 GUEST BED �s ��� A REVISIONS : LL PO E I PERMIT 07.30.07 03 CD #1 10.23.07 1 GU BATH RE-ISSUE 05.13.13 T A F/- 1 1 o LOWE LEVEL T.O.S B FLR +8602'-0" 3 A310 1 o GUEST BED \ � TWOA \ o `\ \ ELEC. PLANS 1 A301 A ] 15 FIRST LEVEL ELECTRICAL PLAN - SIDE B 1 1/4" = 1'-0" LIGHTING SYMBOLS o n GA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET OO SMOKE DETECTOR a ADJUSTABLE DOWNLIGHT COMBO. DATA/TELEPHONE OUTLET 0= DUPLEX OUTLET +18" U.O.N. p♦ RECESSED CAN LIGHT: d: ADJ ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET Q o^ GROUND FAULT DUPLEX OUTLET, o =AA SURFACE MOUNTED LIGHT FIXTURE SWITCH +42" U.O.N. 1 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED W � �} DECORATIVE LIGHT FIXTURE $3 +18" U.O.N. MULTIPLE SWITCH d- C PENDANT LIGHT 4 O• DUPLEX FLOOR OUTLET ` o DIMMER D A DUPLEX FLOOR OUTLET, HALF SWITCHED cc © RECESSED LENSED SHOWER LIGHT $V VARIABLE N® INFLOOR DATA AND QUAD TIMER POWER OUTLET / a SURFACE MOUNTED LIGHT T v = INFLOOR DATA J A POWER OUTLET DUPLEX / o SWITCH IN JAMB \ 24" HALOGEN UNDER CABINET LIGHT i KEY HOMEWORKS KEY PAD T a NEW HOSE BIB / \ Ftl EXTERIOR WALL SCONCE O1 HOMEWORKS CIRCUIT DESIGNATION \` A O NEW JUNCTION BOX / EXTERIOR STEP LIGHT �' BATHROOM EXHAUST FAN \ c A NEW NATURAL GAS LINE / GENERAL ELECTICAL NOTES: 1. TYPICAL COLOR OF DECORA: / \ WHITE - DRYWALL LOCATIONS / BLACK- STONE LOCATIONS, VFY. 2. POWER AND LIGHTING DISTRIBUTION \ TO FOLLOW REQUIREMENTS PER 2003 / OW I RC a RO \ / \ • 3. ELECTRICAL WALK-THRU IS REQUIRED 255 WITH ARCHITECT AT ROUGH-IN } `\ Fl — — / LSe l� 4. VERIFY ALL FLOOR OUTLET LOCATIONS — — ` WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR c. / \ • TVs WITH INTERIOR ELEVATIONS II II ,N II I II ADJ qpJ 11 I I ELECTRICAL PLAN NOTES: O1 PROVIDE GFCI PROTECTED UNDER I I \ \ CABINET PLUG MOLDS AS NECESSARY / I I — w / � It- ti I � —t -lF � �z ENTRY II II II II II / II II II II II II GALLERY B / II II II II II II _ _ R O G KEY - - - 251 1 I I II II I I II II I l 11 II 2s9 O O / / / / / / / I I I I I I IIIIII I I I I IIIIIII�I I I I I I I I I I I I I I --IIIIIIII I I I I I I--IIIIIII I�I I I a I I I G I I I �IIIIIII I I I I I I�IIIIII I I I I I DW E N RY A602 LO ET B GD 25 � T177I 6 I IT II I KITCHEN B 11 11 11 A501 1 1 II 1 TP Y -1 L J — rn s - - o a �I I I -- -- A A Li KEY 220 KEY C i MECH. � CHAS / \ \ I NG MOUNT R CEILING MOUNTED FOR AGE D O ER GA.RAGE DOOR OPENE / \ UDRO M B Lu Lu 254 GARAGE B — C IN / \ • 253 I V ADJ / O LLJ j ADJ \\ A A ' O cc \\ ADJ / \ MATCH LINE / / D HEN O CL_ O PARTY WALL C> i SEPARATION �\ / ° ° 206 O Q j \ I � o, —, O � 6 K EY i CL_ \ I / \ +48" — \ — MATCH LINE i /\/ PARTY WALL O DJ /\ \ SEPARATION I 6 / \ / A 1 1/2" HANDRAIL @ 36" ABOVE i A501 / / w TYP. ADJ A STAIR NOSING TYP. � / - \ Y I 2 A310 LIVING \ ROOM — - - - � — — I 205 \ / PROJECT : OWDER 1 RM. A / w 207 DRAWN B Y VA \ \\ \ 3 DATE : 05.13.13 M,/,STE R C LO. A/ A310 i2 REVISIONS . PERMIT 07.30.01 CD #I 1 0.23.07 RE-ISSUE 05.13.13 D I / / A - - - - - - < A602 1 ELEC. PLANS A ] 16 A301 SECOND LEVEL ELECTRICAL PLAN - SIDE B 1 B 1/4" = 1'-0" r— - LIGHTING SYMBOLS Lin �n -4o 0o o� OA RECESSED CAN LIGHT: N WALL MOUNTED TELEPHONE OUTLET OO SMOKE DETECTOR v r� ADJUSTABLE DOWNLIGHT d�- COMBO. DATA/TELEPHONE OUTLET 0= DUPLEX OUTLET +18" U.O.N. o 0♦ RECESSED CAN LIGHT: a ADJ ADJUSTABLE &/OR SLOPED SPOT TRIM TV 2 RG6 COAXIAL QUAD OUTLET H GROUND FAULT DUPLEX OUTLET, +. Q o cnrl =AA SURFACE MOUNTED LIGHT FIXTURE $ SWITCH +42" U.O.N. v Lu N 1 3-WAY SWITCH DUPLEX OUTLET, HALF SWITCHED �\ �} DECORATIVE LIGHT FIXTURE 3 +18" U.O.N. MULTIPLE SWITCH / \ = a C PENDANT LIGHT 4 O DUPLEX FLOOR OUTLET / \ p DIMMER RECESSED LENSED SHOWER LIGHT DUPLEX FLOOR OUTLET, HALF SWITCHED \ � c / a L VARIABLE Lu $V � \ � N® INFLOOR DATA AND QUAD x L.0% SURFACE MOUNTED LIGHT $T TIMER POWER OUTLET SWITCH IN JAMB F14@1 INFLOOR DATA AND DUPLEX / \POWER OUTLET a \ 24" HALOGEN UNDER CABINET LIGHT J \ KEY HOMEWORKS KEY PAD T Ftl NEW HOSE BIB EXTERIOR WALL SCONCE -EFTA O1 HOMEWORKS CIRCUIT DESIGNATION O NEW JUNCTION BOX / F- o^ �A EXTERIOR STEP LIGHT BATHROOM EXHAUST FAN O NEW NATURAL GAS LINE % \ s \� GENERAL ELECTICAL NOTES: / \ 1. TYPICAL COLOR OF DECORA: WHITE - DRYWALL LOCATIONS \ BLACK- STONE LOCATIONS, VFY. �/ � MASTER � \ 2. POWER AND LIGHTING DISTRIBUTION '/ CLOSET B 353 \ TO FOLLOW REQUIREMENTS PER 2003 / w IRC I I 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS / 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH INTERIOR ELEVATIONS ' I I II II I I II II ELECTRICAL PLAN NOTES: / I I II II I I II II � Ol PROVIDE GFCI PROTECTED UNDER I \ CABINET PLUG MOLDS AS NECESSARY / I I II II I I II II MASTER / BEDROOM B MATCH LINE 351 PARTY WALL ' SEPARATION / I I II II I I II II I /' II II II A t7 I I II II I I II II � / I I II II I I II II � I I II II I I II II I / I I II II I I II II I MUDRM A / — — — I 02 o KEY I A CEILING MOUNTED FOR / GARAGE DOOR OPENER I a I A I \ 352 -77 GARAGE +44 \� I \� 301 = 1 � \ I A310 44 KEY I w \ Y +44 \ � y c / LIB RAORY CEI ING MOUNTED FOR A I v O a GAR GE DOOR OP NER MATCH LINE PARTY WALL I O J SEPARATION KEY i I ENTRY i GALLERY A Y 303 I i w I � I I I 1 1 PROJECT : I DRAWN BY 1 DATE : 05.13.13 REVISIONS : \ PERMIT 07.30.07 CD #1 10.23.07 RE-ISSUE 05.13.13 I 3 A310 / 1 ELEC. PLANS A ] 17 A301 THIRD LEVEL ELECTRICAL PLAN - SIDE B 1 B 1/4" = 1'-0" r� LZ �o �n 0o a� v r_, o r� v Q � J O Q r. H GENERAL ELEVATION NOTES: Lu �\ <8> 6"HALF-ROUND METAL GUTTERS AND DOWNSPOUTS, MO 1 STONE DRY-STACKED MOUNTAIN ASH GRANITE = f• RUN HEAT TAPE AS NECESSARY,VERIFY LOCATIONS ✓) r� W/ROOF PLAN N VERTICAL BOARD AND BATTEN ROUGH SAWN RED CEDAR SIDING.2X2 02 PROPOSED LOCATION FOR UTILITY METERS MO WOOD SIDING BATTENS OVER 1X12 BOARDS,STAINED *_ . ° O 03 WALL MOUNTED LIGHT SCONCE+84"AFF,UON,VERIFY M O WINDOWS AND ALUMINUM CLAD WINDOWS AND DOORS,KYNAR COATED COLOR L O� 0 LOCATIONS WITH EXTERIOR LIGHTING SCHEDULE DOORS CC METAL BELLY FLAT-LOCK,DIRECT APPLIED ZINC PANELS P-0- V BAND AND TRIM —� p M05 ROOF KYNAR COATED STANDING SEAM METAL ROOF W v = MO FASCIA 2X ROUGH SAWN RED CEDAR i Z MO7 COR-TEN VERTICAL STANDING SEAM ZINC SIDING J f— MO CONCRETE EXPOSED CONCRETE IN NON-VISIBLE AREAS FINISH TBD W O f• W GARAGE ROOF-UNITA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ T.O.SHEATHING+8645'-2 1/2" MASTER T.O.ROOF SHEATHING-UNITA T.O.SUB FLR+8628'-0" GARAGE-UNITA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ LIBRARY LEVEL-UNITAAk T.O.PL+8641'-6" T.O.SUB FLR+8626'-0" ENTRY-U NIT A _ _ _ _ _ _ _ _ _ _ _ _ _ _ MASTER T.O.PL-UNITA T.O.PL+8639'-7 3/4" MASTER BEDROOM-UNIT B 03 T.O.PLATE+8639'-0" T.O.SUB FLR+8624'-0"qV LIVING/DINING ROOM-UNITA T.O.PLATE+8622'-6" ws ws ws Q 03 MO 03 ENTRY/GARAGE LEVEL-UNIT A T.O.SUB FLR+8632'-U" 0 MO2 v _ _ _ _ _ _ MASTER BEDROOM-UNIT 8 T.O.SUB FLR+6630' MAIN/MASTER LEVEL-UNIT A T.O.SUB FLR+8614'-0" LIVING/DINING ROOM-UNIT A T.O.SUB FLR+8612'-6" MASTER-UNIT M O �— T.O.PLATE+8624'-0" 3 II II ASOz VI9 W4 W4 EXISTING GRADE M O 1 ENTRY-UNIT B III=III=III=III= (=III=III=PROPOSED GRADS =III=III=III=III= (=III= T.O.SUB FLR 2 —III=III=III=III=III=III=III—III—III—III—III—III=III=III—III—III—III—III—III—I _ _ _ _ _ _ LOWER LEVEL UNITA U —III—III—III—III—III=1 1=III=III=III=III=III=111=III=III=III=III=III=III=1I III T.O.SUB FLR+8602'-0^ IIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII II�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I 1=1 11=1 11=1 11=1 I I-1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 MAIN/MASTER LEVEL-UNIT _ III—III�—�—�— — — — —III—III— —III— —III— —III— = — =III EXISTING GRADE T.O.SUB FLR+8614'-0" - =III=III=III=III=III=III= — G GRA POSED GRADE LOWER TERRACE UNIT T.O.SLAB+8595'-0" EXISTING GRADE 'EXISTING GRADE EXISTING GRADE EXISTING/PROPOSED GRADE AT EDGE OF TERRACE LOWER LEVEL UNIT A _ _ _ _ _ _ _ _ _ _ T.O.SUB FLR+8602'-0" C3HOUSE 31 NORTH ELEVATION HOUSE 31 SOUTH-EAST ELEVATION = 1/4" = P-0" 2 1/4" = P-0" V QW M oQ x °C V � M 55 GARAGE-UNITA O J T.O.PLATE+8641'-6" O Q Q J 03 O1 MASTER-UNITB _ _ _ O T.O.PLATE+6639'-0" _ _ _ _ _ _ _ _ _ _ LIBRARY-UNITA—Ev O —T.O.ROOF SHEATHING+8638'-41/2" Q M03 MO LIBRARY-UNITA T.O.PLATE+8336'-0" m w _ _ _ _ _ _ _ ENTRY/GARAGE LEVEL-UNIT A 04 04 w w _ MOZ T.O.SUB FLR+8632'0" MASTER—UNITB _ T.O.SUB FLR+Sfi30'-0" ------ $LIVINGRM ROOF-UNITB MASTER BEDROOM-UNIT A 7.0.SHEATHING+8629'-2 112" LIVING RM-UNITA� T.O.ROOF SHEATHING+8627'-101/2" T.O.ROOF SHEATHING+8626'-4 1/2" EXISTING GRADE LIVING RM-UNIT B T.O.PLATE+8626'-0" T.O.SUB FLR+8626'-0" T'ASPLATEU+8624'-0" _ M O DINING RM-UNIT B _I T.O.PLATE+8624'-0" T.O.PLATE+8624'-6" IBC LIVING/DINING ROOM-UNIT A T.O.PLATE+6622'-6" � O1 03 M II T.O.SUB FLR 8619'-0" pi 03 wi vu wi O DI LIVING ROOM-UNITB W3 T.O.SUB FLR+861IT MAIN/MASTER LEVEL MAIN MASTER LEVEL-UNITA /' T.O.SUB FLR+8614'-0" T.O.SUB FLR+8614'-0" PROJECT . TL _ _LIVING/DINING RM.-U p �/ T.O.SUB FLR+8612'-6" D R A W N D I Q EXISTING GRADE D5 DATE : 05.13.13 v wu REVISIONS : EXISTING GRADE wi C., w2 ����wis wis T PERMIT 01.30.01 LOWER LEVEL UNITA LOWER LEVEL-UNIT B_ _ _ _ _ T.0 SUe FLR+8602'-0" $T. El FLR+8603'-0" LOWER LEVEL UNITA CD #110. 3.01 PROPOSED GRADE — — O.SUB FLR+8602'-0" o _ - RE-ISSUE 05.13.13 v°a •�p m� _ d° EXISTINGGRAD :e � °'�°° �,�3°'° �.�aee �'• �° q�. X08° .�°. PROPOSED GRADE EXISTING GRADE EXISTING GRADE PROPOSED ELEVATIONS 4 HOUSE 31 EAST ELEVATION 1 HOUSE 31 SOUTH ELEVATION A201 1/8" = 1'-0" 1/8" = 1'-0" r� �o �n 0o a� LZ v r1, v Q � GENERAL ELEVATION NOTES: J O_ O1 6"HALF-ROUND METAL GUTTERS AND DOWNSPOUTS, M01 STONE DRY-STACKED MOUNTAIN ASH GRANITE � RUN HEAT TAPE AS NECESSARY,VERIFY LOCATIONS H W/ROOF PLAN VERTICAL BOARD AND BATTEN ROUGH SAWN RED CEDAR SIDING.2X2 02 PROPOSED LOCATION FOR UTILITY METERS MO2 WOOD SIDING BATTENS OVER 1X12 BOARDS,STAINED -F� Q O O1 p3 WALL MOUNTED LIGHT SCONCE+64"AFF,UON,VERIFY WINDOWS AND ALUMINUM CLAD WINDOWS AND DOORS,KYNAR COATED COLOR W C" LOCATIONS WITH EXTERIOR LIGHTING SCHEDULE Fm—o73 DOORS METAL BELLY FLAT-LOCK,DIRECT APPLIED ZINC PANELS ✓� r� MO BAND AND TRIM M O C ROOF KYNAR COATED STANDING SEAM METAL ROOF 4- J O^ J V O\ MO FASCIA 2X ROUGH SAWN RED CEDAR V M07 COR-TEN VERTICAL STANDING SEAM ZINC SIDING D Q W MO CONCRETE EXPOSED CONCRETE IN NON-VISIBLE AREAS FINISH TBD V _ L Z O J �n W MASTER- NIT B — T.O.PLATE+8639'-0" 0 MASTER-UNITB _ _ _ _ _ _ T.O.SUB FLR+8630'-0" I$LIVING - _ T.O.PLATE RM UNIT B +8626'-0" DINING RM-UNIT B _ T.O.PLATE+8624'-6" ti ° p PROPOSED DRIVEWAY GRADE --------- 3 11 Hill LIVING ROOM-UNITB _ T.O.SUB FLR 8615'-0" PROPOSED GRAD EXISTING GRADE • we \ \ PROPOSED G EXIS ING GRADE Hill III we Hro f / LOWERL EL-UNITB _ T.O.SUB FLR+8603'-0" EXISTING/PROPOSED GRA 2 HOUSE 31 SOUTH-WEST ELEVATION = 1/4" = P-0" V QW M oQ x °C V � T.GARAGE ROOF-UNIT A _ _ _ _ O.SUB FLR+8644'-81/2" O J MASTER ROOF-UNIT B Q Q T.O.SHEATHING+8643'-0" GARAGE-UNITA — — — — — — — — — — J T.O.PLATE+8641'-6" MASTER-UNITB T.O.PLATE+8639'-0" ws ws F17J F w5 M02 ENTRY/GARAGE LEVEL-UNR A T.O.CONCRETE+8632'-0" 11 Hill H] iiiiii 111111 11 MO MO MASTER-UNIT B T.O.SUB FLR+8630'-0" MO LIVING RM-UNIT B O.PLATE+8626'-0" — — — EXISTING GRADE O ENTRY-UNITB F17A _ FEJ- __ T.O.SUB FLR +8619'-0" Moe PROJECT :. . . . . . . . . . . . . . . . . kd T.O SUB FOLRM bis o,�— -- - - - - - - - - D R A W N B Y DATE : 05.13.13 EXISTING GRADE ° REVISIONS : Moi PERMIT 01.30.01 CD #1 10.23.07 RE-ISSUE 05.13.13 LOWER LEVEL-UNITB _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7.O.SUB FLR+8603'-0" PROPOSED TERRACE AND RETAINING WALLS EXISTING GRADE PROPOSED ELEVATIONS 1 HOUSE 31 SOUTH ELEVATION A202 1/8" = 1'-0" r� LZ 0o of v C14 O ,__: V n Q � J O Q r- O� H W O� v r•! 0 -� � V O� V -C p Q V W S n i Z O a W O W ojL UPPER LEVEL T.O.PLATE +86239'-0" �i MASTER -- CLOSET B _— MASTER T R / 353 BATH B MASTER /I/ ROOM /V -' 352 BATH 352 B VVV 3 ojL ENTRY LEVEL _ — — — — — — — — — — — — — — — — — STAIRS -B -iFT.O.SUB FLR +8632'-0" _ _ _ _ OIL UPPER LEVEL ----� T.O.SUB FLR +86230'-0" STAIRS -A ELEVATOR ----------- �� STAIRS -A Q �y ojL LIBRARY LEVEL — MUDROOM B T.O.SUB FLR +8626'-0" 252 0 0 0 POWDER V OJ cl ROOM B O �� - OV 253 O � 0 0 0 0 ENTRY O Q GALLERY B o I. \ 251 J C:> Q STAIRS -A _ _ _ _ _ AMAIN LEVEL T.O.SUB FLR +8619'-0" AS R �/ MASTER MAS ER OWWER DR M SHOWER CLOSET RM. A ELEVATOR 209 210 2 8 207 STAIRS -A STAIRS -B OL DROPPED CEILING DROPPED CEILING MAIN/MASTER LEVEL _ _ _ _ _ T.O.SUB FLR +8614'-0" _ A07 SHELF @ 6'-0" LL FAMILY ROOM B PROJECT : /V LL STAIRS -A MECH B 151 STAIRS -B LL FAMILY WET BAR A 154 DRAWN B Y . ROOM A 1 llo DATE : 05.13.13 11 ELEVATOR = STORAGE/ / i-- CRAWL i REVISIONS : ACCESS -A _ _ _ _ OL LOWER LEVEL PERMIT 07.30.07 T.O.SUB FLR +8603'-0" CD #1 10.23.07 RE-ISSUE 05.13.13 OL LOWER LEVEL —_ _ _ _ _ _ CRAWL SPACE T.O.SUB FLR +8602'-0" T.O.EARTH VARIES UNIT A ELEV. PIT 002 OIL CRAWL SPACE LEVEL _ _ _ T.O.EARTH. +8596'-0' BUILDING SECTIONS 1 HOUSE 31 - LONGITUDINAL SECTION 1/4" = 1'-0" A301 r� �o �n 0o a� LZ v r-, v Q � J O Q lx�1s� Gx�,1x G�%��'Xlxx s //A_ 'A_ �0- ' %� ,� O o� ,., o� v r-4 BLOCKING AS BIBS INSULATION .,_ ,. , ° REQD. TYP. OL v � a a T.O.ENTR OIL T.O.EN_TRY LANDING _ _ _ _ _ 3/4" 8632' - - �, F � �- � 1 ` 1 8639'-7 � z LLJ HEAD TRIM CUT FLUSH TO - 1� TRUSS SYSTEM >< A - T.0. PLATE PAINT GRADE j PLYWOOD SOFFIT: T&G OVER (2) LAYERS Y8" GLASS MAT STONE GYPSUM SHEATHING (1-HR FIRE RATING PER GA ' VENEER FILE NO. RC2601); EXTEND FULL LENGTH OF D==� EAVE FIRE-RESISTANT WALL ASSEMBLY TO EXTEND AND BE TIGHT I I � STONE EXTER. SIDING, OVER BLDG PAPER, OVER %" AGAINST THE EXTERIOR WALLS I I , VENEER NON-COMB. PLYWOOD SHEATHING I I I I ' I I I I BATTEN TYP. T.O.ENTRY LANDING PAINTED METAL FLASHING - PAINTED METAL BELLY T.O.PLYWD. 3RD FLR, CARLISLE ROOL OUT ROOF MEMBRANE BAND 8626' ,��x„_�x,��x„_ BLOCKING AS REQD. -3x16 BLOCKING WITH FABRIC - REINFORCED, HOT LIQUID-APPLIED � � ` CONTINOUS FLASHING WPM; EXTEND MEMBRANE & PROTECTION x x x x BOARD 12” MIN. UP VERTICAL FACE >< ' ' iii - 4 PLYWD. RIP SLEEPERS 4” : 1'-0" TO DRAIN Y4" PLYWD. T&G z o STONE VENEER T.O.WALL ,' ' 1-3/8" FURRED � ' +8622' WALL w/ RIGIND INSULATION %��, CONTINUOUS 1" FILLET BEAD OF T.O.PLYWD. UNCURED NEOPRENE AT 3RD FLR. A CORNERS, PER MFGR. Z 4" SPF IN J( -7 TION - CLOSED CELL / IN.) D==� FLOOR FRAMING, PROPOSED GRADE A-SIDE T.O.PLYWD. 2/3 LANDING Q LLJ 1-3/8" FURRED 8 6 2 0'-1/2'� - - //AA//AA/AA//AA//AA//AA//AA//AA//AA//A/ T,O.WALL '\\/<\X/ V/V/V/V/\/V/V/\ cc CONCRETE CURB WALL w/ RIGIND _ VA V VA VX VA VA VA VA VA VA 0 BEYOND INSULATION ° !� +8622' /V/ // // //X //�//�//�//�//�//�//� ev 0 Q VA VA VA VA VA VA VA VA VA VA VA VA VA cC /\/\Nvvv ° /X< /x // 5 " {� VVA/V A/VA/VA/VA/VA/VA/VA/VA/VA/VA/VA 2X6 FRAMED WALL W/ /s TYPE ■ \/\/\/\/\/\ 'X' DRYWALL, BOTH SIDES; VA VA VA VA VA VA VA VA VA VA VA VA VA EXTEND DRYWALL H O R I Z. AND O %//%//%//%//%//% /% VERTICALLY ALONG ENTIRE Q Q / /A//A//A//A/ PARTY WALL. (UL-LISTING NO. p T.O.PLYWD. 2/3 LANDING PROPOSED GRADE /\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\ U341) Q J a / / / / / / /��/�� 2 X 6 FRAMED WALL W/ /s TYPE 'X' DRYWALL, BOTH SIDES; EXTEND DRYWALL H O R I Z. AND ° // // // // VERTICALLY ALONG ENTIRE / / /�/�/X/�/�/�/�/�/�/� T.O.PLYWD. FLR. � / /�//��/�/ / / �/���������//��/�/ � / / � 8602' K PARTY WALL. UL-LISTING NO. // x/ // //// // //// // //// //// // /// / l� j `��1 1" CLEAR AIRSPACE ° �/x�j/��%��j��% }� �� �� l �� B ETW. FRAMING T.O.PLYW D. 3RD FLR. B a ° T.O.PLYWD. 1ST FLR. as „_ „_ „_ �� �� x x x „_ „_ �� x „__ „__ x ��% �% ���,�- x���„_-„ ' G ��,� x x x � 8602' P R 0 J E C T `T X 'S X \X 1'i, x„_"i^,� ,XK//X//-x//-4- //� //� //-y. /-4i /K�/ �-� .5,\��T�✓�.,x'i-„�`iT,�`i`,x ,X //- //� //� �� -Y/ -4/'�-//MX/��/�� /-4- -1r �M �-, �. %� x� x� xG y �,� � %�s �x%�- -x� t= FLOOR R FRAMING, V- „� � � � �, �xx � � x �_� ��_ DRAWN BY : � _ ,� ,�_ ��- �� _° , ; � �,G �,��//G`� G B-SIDE DATE . 05.13.13 ° x T.O.PLYWD. 1ST FLR. A REVISIONS : PERMIT 01.30.01 a CD #1 10.23.01 CONCRETE FOUNDATION WALL PER REISSUE 05.I3.I3 FLOOR FRAMING, STRUCTURAL ENGINEER A-SIDE < a a ° < ° a a < zn ° `5 n u u N�N /$ GYP AT ALL\CRAWLSPACESTYP / / / / WALL SECTIONS ZA dL T.O.FOOTER �� �� � �����xX/� ������\ ° L ° C RAW L S PACE T.O.FOOTER CRAWL SPACE ° 4 � 3 STAIR SECTION WALL DETAIL 2 STAIR SECTION WALL DETAIL 1 TYPICAL PARTY WALL DETAIL A31 0 3/4' = 1'-0' 1' = 1'-0' 1-1/2' = 1'-0” CLIP TO SEAM SNOW FENCE LIZ v� �o �n 00 a, METAL STANDING SEAM ROOF k_j r14 o SELF-ADHERING, RUBBERIZED Q c� ASPHALT ROOFING J ° REFER TO UL DESIGN NO. U305 UNDERLAYMENT AND/OR GYPSUM ASSOCIATION Ln RAINSCREEN O/ BUILDING PAPER O/EXTERIOR SHEATHING FILE NO. WP 8130 12 3/q" CDX PLYWD Q LAP O/ FLASHING BELOW W CT BOARD AND BATTEN SIDING EXTEND BOARD TO L, FLASHING BELOW RUNNING CONT. BEHIND 2X12 WEATHER EXPOSED CLADDING VARIES, SEE ° o PLANS *— J a 2X12 SMOOTH SAWN RED CEDAR SIDING HOLD Ya" OFF ONE LAYER Ya" TYPE "X" GLASS MAT GYPSUM , ,�� FLASHING EXTERIOR SIDE SHEATHING �'�� 7� ��� -4-- Q W V S IJ'`� /Fl F IF F-I El F-I METAL FLASHING CAP \ � J 1 7�)�. W RAFTER RE: STRUCT W/ 3" o SPRAY-IN POLY-ISO + 8-7/8" 2x8 FASCIA BIIBS = R-58 - TAPE AND COVER JOINTS AND SCREW HEADS VAPOR BARRIER 6" z ROUND METAL W/ FIBER TAPE AND JOINT COMPOUND GUTTER TO MATCH INTERIOR SIDE Ya" GYP. BOARD ROOFING MATERIAL 6" STONE VENEER O/ MASONRY DRAINAGE MAT OR GLASS FIBER INSULATION, MIN. DENSITY OF VAPOR BARRIER 1"AIRSPACE O/ BUILDING PAPER O/EXTERIOR SHEATHING 0.80pcf, W/A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS, 5-1/2" EXT. STUD WALL, W/ R-21 2x10 SUB-FASCIA FRICTION FITTED TO COMPLETELY FILL CAVITIES MIN. INSULATION, TYP, U.O.N 4'-0" WOOD STUDS EFFECTIVELY FIRESTOPPED 1/2" T&G PLYWD END OF RAFTER SHEATHING CONTINUOUS • ONE LAYER Ya" TYPE "X" GYPSUM WALL BOARD BLDG PAPER SUBFASCIA 1x4 V-GROOVE SIDING MATERIAL, VARIES T&G SOFFIT 9 BELLY BAND DETAIL 6 UL WALL DETAIL 3 ROOF EAVE DETAIL • 1" = r-0. 1 1/2" = l'-0" 1 1/2" = l'-0" �C FINISH FLOOR LIGHTWEIGHT CONC. W/ RADIANT HEAT COPPER FLASHING; SEAL LAPS d SURE-SEAL/SURE-WHITE LAP SEALANT �` ` SEALANT INSTALLED PER MANUFACTURERS DIRECTION METAL CAP, SLOPE 1"/FT. MIN. ` SURE-SEAL INSULATION STANDING SEAM METAL ROOF w/ 6" TO DRAIN FRONT TO BACK, TYP. \ ` 1/" EXT. PLYWD. SHEATHING TURNDOWN i BLOCKING TYP. ____________� \\\ \\ 6" STONE VENEER RIP SLEEPERS q . 1 0 TO DRAIN Yq" PLYWD. T&G ° BUILDING PAPER i STL. ANGLE SUPPORT BEYOND ` 4" SPF INSULATION - �° i CEMENTIOUS UNDERLAYMENT N a SHEET BITUTHANE; EXTEND MEMBRANE 12" MIN. i WITH WATERPROOFING AND ONTO PRIMED SHEATHING AND MIN. 6" BELOW ANGLE CLOSED CELL (R-7 / IN.) i ° F o i SHEET METAL CLADDING, SLOPE 2' DRAIN AND DRY BOARD TO DRAIN 1/4" PER FT. LIQUID FILLET OF LM3000 BY GRACE ° REMOVEABLE STEEL MESH �����`� HOT APPLIED MONOLITHIC WATERPROOFING PLAN VIEW SCREEN AND FRAME ATTACHED MEMBRANE -- EXTEND WATERPROOFING 36" ABOVE %q"0 2"O.C. STL ° STEEL ANGLE, PAINT BLACK ` GRADE AND TO BOTTOM OF FOOTING MESH, , VFY. MAINTAIN 1/2" SPACE BETWEEN ,', STAINLESS STL ANCHORS (THREADED EXTENSION SCREEN AND SILL FLASHING FOR ' W/ NUT TO SECURE ANGLE). DETAIL 4"x4"xYq"STL. ANGLE DRAINAGE SURE-SEAL TERMINATION BAR SUPPORT WITH BASE WATERPROOFING AROUND ANCHOR PENETRATIONS SURE-SEAL WATER CUT OFF MASTIC PLATE, PAINT BLACK METAL FLASHING SANDSTONE CHIMNEY ',' METAL FLASHING AT CHIMNEY LINE OF GRADE CAP ABOVE a a SCREEN SILL ,' SLICKER SCREEN SANDSTONE STONE CAP a ',' 4" SANDSTONE CAP W/ CLEFT RAFTER RE: STRUCT W/ BELOW a a a ' EDGES, SLOPE Y4"/FT. MIN. TO ° R-38 MIN. BIBS INSULATION j DRAIN, TYP. �o 6" STONE VENEER O/ BLDG. CARBON STL SUPPORT ANGLE - SHOP PRIMED W/ 2 Q L J VAPOR BARRIER PAPER AND DRAINAGE MAT COATS EPDXY PAINT Y$" GYP. BOARD / / ° ^n �','��� HOT-APPLIED MONOLITHIC WATERPROOFING Z � VAPOR BARRIER ',/ a MEMBRANE Q JO 5-1/2" EXT. STUD WALL, W/ R-21 DRAIN & DRY BOARD MIN. INSULATION, TYP, U.O.N O � Q 1/2" T&G PLYWD CONCRETE FOUNDATION WALL PER STRUCT. SHEATHING 5 CHIMNEY CAP DETAIL 2 WALL DETAIL Q J BLDG PAPER 1 1/2" = 1'-0" 1 1/2" = l'-0" SLICKER SCREEN CORTEN SIDING CONC FDN WALL RE: STRUCT. O 2" O.D. TUBE STEEL SPOT WELDED TO VERTICAL 8 HOT-APPLIED, MONOLITHIC FLAT BAR POWDER COAT WATERPROOFING MEMBRANE-- EXTEND FINISH FLOOR WATERPROOFING 36" ABOVE GRADE AND LIGHTWEIGHT CONC. TO MATCH WINDOWS TO BOTTOM OF FOOTING TYP. z" lz" W/ RADIANT HEAT 1-3/8" FURRED WALL W/ RIGID INSUL., TYP. - - CLEAN AND DE-BURR ALL �" ri 5/a" DRYWALL, TYP. ° a DRAIN & DRY BD %" EXT. PLYWD. SHEATHING WELDS, PROVIDE SAMPLE GRAVEL THIS AREA REGARDLESS OF EXPANSION MATERIAL WHETHER DRAIN IS LOCATED AT THIS CONC. SLAB RE: ° LOCATION STRUCT. MIN. 1" X 1" BUILT-UP CANT OF PROJECT BUILDING PAPER IMBEDED IN LIQUID mrr; _ a FLUID-APPLIED WATERPROOFING AT ALL D R A W N B Y FILLET OF LM3000 "'" 1-1/4"" O.D. TUBE STEEL 10MIL. VAPOR BARRIER INSIDE CORNERS D A T E 05.13.13 SPACER BLOCK O/ R-10 MIN. RIGID FILTER FABRIC CORTEN SIDING TYP. MAINTAIN 2" CLR. m FOAM INSULATION ° REVISION S FROM GRADE n a O �O �/ CLEAN 3/4" FREE DRAINING GRAVEL PERMIT 01.30.01 zn <1 LIQUID FILLET OF LM3000 BY GRACE m _ �/ O CD #1 10.23.01 HOME SLICKER DRAIN MAT w/ SLICKER T.O. FTG RE-ISSUE 05.13.13 SCREEN AT BASE MAINTAIN 6" CLEAR "rn - ------------------------ zj < SEE STRUCT DWGS FROM GRADE "" --- -- ------_---------- ° �/" SQUARE BAR STOCK j, '� PLYWOOD FURRING STRIPS AS REQD. - t ° ��j 00 FOR CORTEN INSTALATION Mr', SLICKER SCREEN _ 4" FREE DRAINING 1° HOT-APPLIED MONOLITHIC m �" GRAVEL, NO FINES N WATERPROOFING MEMBRANE EXTEND ANGLE BRACKET WITH FINISHED HEX HEAD BOLT WATERPROOFING 36" ABOVE GRADE = WATER STOP, TYP. ° AND TO BOTTOM OF FOOTING M"' 6" O, RIGID, PERFORATED PIPE SLOPED @ LINE OF GRADE CONC FTG RE: STRUCT. Y4" PER FOOT TO A DAYLIGHT OR A SUMP DETAILS LOCATION CONC. FND. WALL PER STRUCT. 7 CORTEN WALL DETAIL 4 RAILING DETAIL 1 FOUNDATION DETAIL A501 1 112° = l'-0" 1 112" = 1'-0" 1 1/2° = l'-0" r� �o �n 0o a� LZ v r-, v Q � J O Q H W Ol V 1— N _ �_ ✓� Lu O *— J V O" STEEL RAILING, SEE DETAIL -� o a ALUMINUM CLAD z DOOR, SEE DOOR z SCHEDULE o J 5/3 DRIP-THROUGH STL ,,~�W BAR GRATE DECKING T.O. FND. WALL/SLAB o_ 4 �/z" STL ANGLE DECKING +8602'-1 SUPPORT ^' STEEL C-CHANNEL, W SEE STRUCT. METAL FLASHING 4 4 STONE VENEER � 3 FRENCH BALCONY DETAIL • ZURN 5x5 ZS415S DRAIN (WRAP W/ FILTER FABRIC), HEAT TRACE DRAIN AND PIPING BACKER ROD AND SEALANT STONE FINISH, TBD; SAWCUT REVEAL AT DRAIN TO RECEIVE BACKER ROD AND SEALANT SLOPE SLOPE 1 Y - 2" LIGHTWEIGHT TOPPING W/HYDRONIC SNOW MELT TUBING, VFY THICKNESS W/ FINISH MAT'L O O DRAINAGE MAT a Y$" ASPHALTIC PROTECTION BOARD a a FABRIC - MONOLITHIC MEMBRANE W/ FLEX FLASH F REINFORCEMENT FABRIC & HYDROFLEX 30 CAP SHEET 6° MIN. _ 6" CONC SLB SLOPING TO 4" AT DRAIN O/STEEL DECKING, RE: STRUCT QW FLOOR FRAMING PER oC O STRUCTURAL ^n 0 x Z oC V � DRAIN PIPE -- RE: MECH. Q OV DWGS FOR ROUTING & SIZE O J Q Q FLOOR DRAIN DETAIL Q J 3" = 1'-0" 4 72 O 4" SANDSTONE CAP Y4" QUIRK MITRE, TYP. �N V V 2X6 CEDAR TRIM ;%j PROJECT : d m ° STONE VENEER BLOCKING -� DRAWN B Y a PAVERS TYP. 1x10 WESTERN RED D A T E 05.13.13 d ' CEDAR LAP SIDING, GRADE A OR BETTER CONC. PER STRUCT. Y$" GYP. BOARD R E V I S I O N S d PERMIT 01.30.01 VAPOR BARRIER CD SU 1 10.13.01 5-1/2° BAIT. INSUL. RE-ISSUE 05.13.13 d ° a ° BLDG PAPER -� (R-19) d z" PLYWD SHEATHING METAL FLASHING BLOCKING AS REQD. FLAT LOCK DIRECT APPLIED METAL BELLY BAND STEEL PER STRUCT. DETAILS 1 WOOD SIDING CORNER DETAIL A502 STONE WALL DETAIL 3" = 1'-0" 4 3/4" = 1'-0" 6n 6n Lj_ �o Ln 0o v� v O '" V J O • Q n H , -F► Q O� W C" C-4 = 1-_ O V O� •� CC 2'-1" 2'-7" 2'-7" V 3'-5" R.0. R.O. R.O. R.O. HEAD HEIGHT R.O. R.O. R.O. R.O. W 3'-1" +8'-0" AFF R.O. o \\\ ) J r1 0 W 1� O � O ' ion _o � al: O ^ O r LIBRARY A#204 HEAD HT=7'-0" 1n VERIFY HEAD HEIGHT to FOR WINDOWS IN Lu GARAGE A#201 HD HT=7'-0" STAIR,+18'-6"AND w +11'-6"AFF LOWER �v - Q MASTER BED RM B#251 HD HT= LEVEL � i N N / p LL N > 6'-8" N N T.O. SUBFLOOR Wl PICTURE WINDOW W2 CASEMENT WINDOW W3 CASEMENT WINDOW W4 CASEMENT WINDOW WS CASEMENT WINDOW W6 CASEMENT W7 NOT USED W8 CASEMENT WINDOW 1 ,119 CASEMENT WINDOW TEMPERED TEMPERED, EGRESS TEMPERED EGRESS EGRESS 1'-7" 12 11 4'-981 1111 • " -5 11 5 -0 2 3'-1" 31-111 1,-7„ R.O. R.O. R.O. R.O. R.O. R.O. R.O. R.O. 9,_9, HEAD HEIGHT R.O. +7'-0" AFF O oC d 1� O �Iv is H r� M O O C) O ry) _ 00 cl: E a 60 °C °? LL N O fV fV N M fv1 r-I - M m (n (n T.O. SUBFLOOR ��� CASEMENT WINDOW ,,,�,� CASEMENT WINDOW �,� CASEMENT WINDOW ,,,��� CASEMENT WINDOW FRENCH CASEMENT �� 4 PANEL SLIDING DOOR �� FR. INSWING DOUBLE DR �� 3 PANEL SLIDING DOOR �� 4 PANEL SLIDING DOOR vviv vvll vvic vvl� O EGRESS 5'-31" 2 R.O. V QW Fo 2 O M oQ oc rn O Q Q T.O. SUBFLOOR act � O D5 2 PANEL SLIDING DOOR EXTERIOR WINDOW AND SCHEDULE KEY:A=ACTIVE LEAF;T=TEMPERED; E=EGRESS EXTERIOR WINDOW AND SCHEDULE KEY:A=ACTIVE LEAF;T=TEMPERED; E=EGRESS WINDOW TYPE/ FRAME WINDOW WINDOW MANUFACTURER'S WINDOW TYPE/ FRAME WINDOW WINDOW MANUFACTURER'S NO. MANUF. MAT'L. SIZE R.O. CALL GLAZING* REMARKS NO. MANUF. MAT'L. SIZE R.O. CALL GLAZING* REMARKS W x H W x H NUMBER W x H W x H NUMBER W1 JELD-WEN ALUM. CLAD 3'-4" x 7'-0" 3'-5" x 7'-1" CCCP4084 LOW E II CASEMENT UNIT D1 JELD WEN ALUM. CLAD 12'-4" x 8'-2 1/2" 12'-5" x 8'-3" CWGPDT12080Q LOW E II SLIDING - EXTERIOR PATIO DOOR 4-PANEL UNIT P R 0 J E C T W2 WOOD WINDOWS 3'-0" x 7'-0" 3'-1" x 7'-1" CCCP3684 CASEMENT UNIT- EGRESS D2 JELD WEN WOOD DOORS 5'-0" x 7'-11 3/4" 5'-1" x 8'-0 1/4" CNGPDR5080 SLIDING - EXTERIOR PATIO DOOR TWO-PANEL UNIT DR A W N B Y : W3 3'-0" x 5'-6" 3'-1" x 5'-7" CCCP3666 CASEMENT UNIT D3 JELD WEN 8'-0 1/2" x 8'-2 3/4" 8'-1 1/2" x 8'-3 1/4" CNGPDT7680 SLIDING - EXTERIOR PATIO DOOR THREE-PANEL UNIT DATE : 05.13.13 W4 2'-0" x 5'-0" 2'-1" x 5'-1" CCC2460 CASEMENT UNIT D4 JELD WEN 9'-8" x 6'-7 1/2" 9'-9" x 6'-8" CNGPDR10068Q SLIDING - EXTERIOR PATIO DOOR FOUR-PANEL UNIT W5 2'-6" x 2'-6" 2'-7" x 2'-7" CCC3030 CASEMENT UNIT D5 JELD WEN 5'-2 1/2" x 8'-2 3/4" 5'-3 1/2" x 8'-3 1/4" CNGPDT5080 SLIDING - EXTERIOR PATIO DOOR TWO-PANEL UNIT W6 2'-6" x 5'-6" 2'-7" x 5'-7" CCC3066 CASEMENT UNIT REVISIONS W7 NOT USED PERMIT 01.30.01 W8 3'-0" x 4'-6" 3'-1" x 4'-7" CCC3654 CASEMENT UNIT CD #1 1 0.23.01 W9 3'-0" x 5'-0" 3'-1" x 5'-1" CCC3660 CASEMENT UNIT- EGRESS RE-ISSUE 05.13.13 W10 3'-0" x 3'-0" 3'-1" x 3'-1" CCC3636 CASEMENT UNIT W11 3'-0" x 4'-0" 3'-1" x 4'-1" CCC3648 CASEMENT UNIT W12 1'-6" x 4'-0" l'-7" x 4'-1" CCC1848 CASEMENT UNIT W13 l'-6" x 7'-0" 1'-7" x 7'-1" CCC1884 CASEMENT UNIT W14 4'-8" x 5'-0" 4'-9" x 5'-1" CCC4R5660 FRENCH CASEMENT UNIT- EGRESS WINDOW AND DOOR SCHEDULE A601 4" 16 60 HEAD AND CASE WINDOW TRIM TO v e-4 MATCH DOORS v INTERIOR / J O DRYWALL` THREE PANEL d o� MAHOGANY INTERIOR LLI (-n DOORS WITH FLAT, Q O 2 x HEADER \ / a" SHAKER STILE AND mN 4- ,, a RAILS,TYP. ALL MECHANICAL v � r SHIM SPACE / 15 OPERATORS AND SILL AND APRON TO EQUIPMENT PER N 6O MANUFACTURER'S o HEAD/CASE / MATCH HEAD TRIM d SPECIFICATIONS v a \ Co TRIM,TYP. ~'n "1oJ N *INSTALLER TO V y N FIELD VERIFY J-�3g INDICATED SIZESz 2x3 SS CEDAR TRIM v =Ll W LEGS& HEAD Z W a STOP HEAD& 4 I„ ul Q w &lx8 SS HEAD EDAR BUCK LEGS a g W INTERIOR DOOR, CASE JAMB/APRON CASE HEAD BASE TRIM HANDRAIL TRIM GARAGE DOOR TBD o TYP. BAS-320 FROM HND-1435-M FROM SCHACHT MILL SCHACHT MILL WORKS WORKS 14 5 C0 (jQ EXTERIOR (:16 TYP INT. DOOR HEAD DETAIL 12 TYP INT. TRIM DETAILS 8 TYP INT. DOOR AND CASING DETAILS 4 TYP GARAGE DOORJAMB DETAIL 3" = P-0" 3" = 1'-0" N.T.S. 3" = P-0" V PLUS,OR SIM. ON VYCOR PLUS, OR SIM. ON ALL LL SIDES OF OPENING W/ ALL SIDES OF OPENING W/ 30# FELT OVERLAY; LAP 30# FELT OVERLAY; LAP JOINT OVER FLASHING 2X WALL W/R-21 JOINT OVER FLASHING INSULATION 2X WALL W/R-21 INSULATION I / � STONE VENEER BLDG PAPER; HOLD BACK INTERIOR DOOR %$" DRYWALL / BLDG PAPER; HOLD BACK %$" DRYWALL 3"ALL SIDES OF DOOR OR PER MANUF. SPEC. I / 3"ALL SIDES OF DOOR I OR PER MANUF. SPEC. IL 4" 4" III / / LAP SIDING TYP. JAMB&STOP VAPOR BARRIER • HEAD CASING TYP. VAPOR BARRIER III / / METAL FLASHING W/ I / / / HEMMED DRIP EDGE PAINT � TBD / / Y2"SHIM SPACE i JAMB TRIM,TYP. INTERIOR � / / INTERIOR INTERIOR CASING TYP. SEE CASING TYP. SEE � TRIM DETAILS SHIM SPACE JAMB TRIM DETAILS CASING 2X8 SMOOTH SAWN RED CEDAR TRIM. 2X WALL TYP. DOORJAMB p SUPPORT PER STRUCT. DOORJAMB p SEALANT AND d DRYWALL BACKER ROD,TYP. SEALANT AND DOOR TYP. BACKER ROD,TYP. BASE TRIM, ALUMINUM CLAD DOOR, SEE ALUMINUM CLAD DOOR, SEE BELOW EXTERIOR WINDOW AND DOOR EXTERIOR WINDOW AND DOOR SCHEDULE SCHEDULE 12 EXTERIOR EXTERIOR 15 TYP INT. DOORJAMB DETAIL 11 TYP INT. DOOR CASING DETAIL 7 TYP EXT. DOOR HEAD DETAIL @ STONE VENEER 3 TYP EXT. DOOR HEAD DETAIL @ WOOD SIDING 3" = P-0" 3" = 1'-0" 3" = 1'-0" 3" = P-0" 2X WALL W/R-21 INSULATION 2X WALL W/R-21 INSULATION DRYWALL Z EXTERIOR DRYWALL EXTERIOR INTERIOR DOOR, / / STONE VENEER BOARD AND BATTEN VAPOR BARRIER V SIDING TYP. TYP. CASE TRIM / BEYOND / / / BLDG PAPER; HOLD BACK JAMB&STOP Y2"SHIM SPACE / / 3"ALL SIDES OF WDW VAPOR BARRIER O j/ / PER MANUF. SPEC. I BLDG PAPER; HOLD BACK LLJ / 1" SHIM SPACE OR ALL PER MANUF. SP OR / TRIM, BEYOND / / / pC C> BASE TRIM INTERIOR / / / 0 Q / / INTERIOR INTERIOR DC � / Z THRESHOLD IN CASING TYP. SEE / CASING TYP. SEE 2X6 SMOOTH SAWN RED J WOOD FLOOR TRIM DETAILS 'O TRIM DETAILS CEDAR TRIM. g STONE JAMB RETURN DOORJAMB p DOORJAMB p SEALANT AND SEALANT AND d BACKER ROD,TYP. ° a � ° °° � BACKER ROD,TYP. ALUMINUM CLAD DOOR,SEE O ALUMINUM CLAD DOOR, SEE EXTERIOR WINDOW AND DOOR WOOD FLOOR OVER FIN. LOOR OVER 2" EXTERIOR WINDOW AND DOOR SCHEDULE 2"GYPCRETE GYPCRETE SCHEDULE CARPET OVER 2" 2x DOUBLE SOLE GYPCRETE PLATE @ STUD O WALLS ,TYP. TYP INT. DOOR FLOOR DETAIL TYP INT. BASEBOARD TRIM DETAIL TYP EXT. DOORJAMB DETAIL @ STONE VENEER TYP EXT. DOORJAMB DETAIL @ WOOD SIDING (:14 3' = P-0" (:l 0 N.T.S. 6 3" = 1'-0" 2 3" = P-0" -COPPER PAN FLASHING W/1" ALUMINUM CLAD DOOR, SEE -COPPER PAN FLASHING W/1" ALUMINUM CLAD DOOR, SEE EB-TY HIDDEN FASTENER SYSTEM TO ATTACH P R 0 J E C T UPTURNED EDGE&END DAMS EXTERIOR WINDOW AND DOOR UPTURNED EDGE&END DAMS EXTERIOR WINDOW AND DOOR IPE DECKING TO FLOATING SUB-FRAME (FULLY SOLDERED)SET IN A SCHEDULE (FULLY SOLDERED) SET IN A SCHEDULE RE-SAWN RED CEDAR FASCIA DRAWN B Y CONTINUOUS BED OF SEALANT CONTINUOUS BED OF SEALANT COPPER FLASHING COPPER FLASHING BLOCKING AS NECESSARY D A T E 05.13.13 FINISH FLOOR FINISH FLOOR QUARTSITE TILES IN MORTAR BED w/ SNOW MELT TUBING / / / / / / / / / 5/4X4 IPE DECKING CONTINUOUS SUB-FASCIA ul } FABRIC-REINFORCED, HOT LIQUID-APPLIED WPM N a REVISIONS : O I 0 (AH6125FR) EXTENDED TO ENCAPSULATE PERMIT 01.30.01 Lo w COPPER PAN FLASHING @ THRESHOLD AND 2 CD #1 10.23.01 < r @ EXTENDED 3'-0" MIN OVER CONC. SLAB \ RE-ISSUE 05.13.13 BACKER ROD& � BACKER ROD& SEALANT SLOPE CONC.TO DRAIN 1/$" : 1'-0" SEALANT BLOCKING a 7/7//7/-// BLOCKING O / �/ �/ / O4 � O 2 o - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BACKER ROD AND SEALANT 4 G</ < Q (EXPANSION JOINT) o Z3 � � 4 < a 10 4 < a 4 4 4 4 BACKER ROD AND SEALANT' < 4 4 4 (EXPANSION JOINT) a � 4 � 4 4 a DOOR DETAILS Q 4" SLAB ON GRADE EXPOSED JOISTS PER STRUCT. 4 TYP PATIO DETAIL TYP ABOVE GRADE DECK DETAIL A602 13 3" = P-0" 1 3" = P-0" INTERIOR DOOR SCHEDULE DOOR PANELS REMARKS MASTER ROOM DOOR ROOM NAME HARDWARE SIZE R.O. SWING HINGES THICK- MAT'L THRESH- MAT Ln DR.NO. NO. NO. NESS OLD V e-4 O l 1 001 1 UNFINISHED STORAGE PASSAGE 3'-0"x 4'-0" 3'-1"x 4'-5 1/2" LH 2 1-3/4" NONE 20 MIN.w SELF CLOSER 2 102 1 LL LAUNDRY PASSAGE 3'-0"x 8'-0" 3'-1"x 8'-5 ' LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR n 3 103 1 LL POWDER PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR LENTIL TRIM 4 104 1 LL BATH 3A PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR LENTIL N J O 5 105 1 LL BED 3A PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR TRIM O� 6 105 2 LL BED 3A PASSAGE 4'-6"x 8'-0" 4'-7"x 8'-5 1/" DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR H 7 106 1 LL BED 2A PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 1 4— Q p 8 DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR O� 106 2 LL BED 2A PASSAGE 4'-6"x 8'-0" 4'-7"x 8'-5/" ,, J 01" 9 107 1 LL BATH 2A PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR JAMB V nl 10 108 1 GUEST BATH 1A PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5%" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR TRIM = n 11 109 1 GUEST BED 1A PRIVACY 3'-0"x 8'-0" 3'-1"x 8'-5 X" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR WINDOW TYP, WINDOW TYP. 12 109 2 GUESTBED 1A PASSAGE 2'-4"x 8'-0" 2'-5"x 8'-5 1/" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR O 13 112 1 LL LINEN CLOSET PASSAGE 3'-0"x 8'-0" 3'-1"x 8'-5 Y2" DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR A J r� 14 1 113 1 IHALL 1-3/4" PASSAGE 3'-0"x 8'-0" 3'-1"x 8'-5 RH MAHOGANY NONE 20 MIN.w SELF CLOSER 15 207 1 POWDER ROOM A PRIVACY 2'-6"x 8'-0" 2'-7"x 8'-5 Y2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 2 V 16 208 1 MASTER CLOSET A PASSAGE 2'-4"x 8'-0" 2'-5"x 8'-5 1/Z" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR L 17 209 1 MASTER BED A PRIVACY 2'-6"x 8'-0" 2'-7"x 8'-5]" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR C Q 18 210 1 MASTER BATH A PRIVACY 2'-6"x 8'-0" 2'-7"x 8'-5 1/2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR V W 19 210 2 MASTER BATH A PRIVACY 2'-0"x 8'-0" 2'-1"x 8'-5]" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR S 20 301 1 GARAGE A PRIVACY 3'-0"x 8'-0" 3'-1"x 8'-5 1/2" RH 1-3/4" MAHOGANY NONE 20 MIN.w/SELF CLOSER WINDOW TYP. WINDOW TYP. JAMB 21 302 1 MUDROOM A PASSAGE 3'-0"x 8'-0" 3'-1"x 8'-51/2" DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR TRIM J 22 302 2 MUDROOM A PASSAGE 3'-0"x 8'-0" T-1"x 8'-5/z" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 23 152 1 GUEST BED 2B PASSAGE 4'-0"x 8'-0" 4'-1"x 8'-5'/2" DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR a~/f 24 152 2 GUEST BED 2B PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 Y2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR W 25 153 1 GUEST BATH 2B PRIVACY 2'-6"x 8'-0" 2'-7"x 8'-5 Y2" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 26 154 1 MECHANICAL B PASSAGE 3'-0"x 8'-0" T-1"x 8'-5 1/2" LH 1-3/4" MAHOGANY NONE 20 MIN.w/SELF CLOSER O 27 155 1 LL STORAGE B PASSAGE 2'-6"x 8'-0" 2'-7"x 8'-5]/2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR SILL TRIM Ln 28 156 1 GUEST BED 3B PASSAGE T-0"x 8'-0" T-1"x 8'-5 1/2" DOUBLE 1-3/4" MAHOGANY NONE INTERIOR SLAB DOUBLE DOOR 29 156 2 GUEST BED 3B PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5]" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 30 157 1 GUEST BATH 3B PRIVACY 2'-6"x 8'-0" 2'-7"x 8'-51/2" RH 1 1-3/4" IMAHOGANY NONE I INTERIOR SLAB DOOR 31 252 1 ENTRY CLOSET B PASSAGE 2'-2"x 8'-0" 2'-3"x 8'-5 Y2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 32 253 1 GARAGE B PRIVACY 3'-0"x 8'-0" T-1"x 8'-5 1/z" LH 1-3/4" MAHOGANY NONE 20 MIN.w/SELF CLOSER 33 254 1 MUDROOM B PASSAGE 3'-0"x 8'-0" 3'-1"x 8'-5 lf" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 34 255 1 POWDER ROOM B PRIVACY 2'-4"x 8'-0" 2'-5"x 8'-5 1/2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 8 EXTERIOR WINDOW D ETA I L@ STO N E V E N E E R 4 R 1 O R WIND O W D ETA I L@ B&B S I D I N G 35 351 1 MASTER BED B PRIVACY 3'-0"x 8'-0" 3'-1"x 8'-5 1/2" LH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 36 352 1 MASTER BATH B PRIVACY 3'-0"x 8'-0" T-1"x 8'-51/2" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR N.T.S. 37 352 2 MASTER BATH B PRIVACY 2'-0"x 8'-0" 2'-1"x 8'-5 Y2" RH 1-3/4" MAHOGANY NONE INTERIOR SLAB DOOR 38 1 353 1 1 IMASTER CLOSET B IPASSAGE I 2'-8"x 8'-0" 1 2'-9"x 8'-5 1" ILH I T 1 1-3/4" IMAHOGANY INONE I I INTERIOR SLAB DOOR *=OVERHEAD CONCEALED DOOR CLOSERS **=SPRING HINGE DOOR CLOSERS EXTERIOR • INTERIOR DOOR SCHEDULE � EXTERIOR 16 N.T.S. EXTERIOR BLDG PAPER; HOLD BACK 3" ALL SIDES OF WDW PER / TYP. MASONRY WALL BLDG PAPER; HOLD BACK 3" MANUF. SPEC. 2-A501 SEE DETAIL BLDG PAPER; HOLD BACK 3" ALL SIDES OF WDW PER VYCOR PLUS, OR SIM. ON 2-A501 ALL SIDES OF WDW PER MANUF. SPEC. ALL SIDES OF OPENING W/ MANUF. SPEC. TYP. B&B WALL CONST. i TYP.CORTEN WALL 30# FELT OVERLAY; LAP �i' SEE DETAIL 3-A501 • VYCOR PLUS,OR SIM. ON CONST. SEE DETAIL JOINT OVER COPPER / / / I� METAL FLASHING W/ ALL SIDES OF OPENING W/ I 1-A501 FLASHING / / HEMMED DRIP EDGE PAINT 30# FELT OVERLAY; LAP / / / TBD JOINT OVER FLASHING STONE VENEER TYP. / H 7 EADER PER STRUCT. --� I� VYCOR PLUS, OR SIM. ON HEADER PER STRUCT. ---- – ALL SIDES OF OPENING W/ METAL FLASHING W/ METAL FLASHING W/ 30# FELT OVERLAY; LAP HEMMED DRIP EDGE PAINT 1 JOINT OVER FLASHING I HEMMED DRIP EDGE PAINT \ HEADER PER STRUCT. TBD /2" SHIM SPACE J I TO MATCH STONE I � I �" SHIM SPACE MAHOGANY CASING SEE j CASING SEE TRIM DETAILS 1 2X2 SMOOTH SAWN RED TRIM DETAILS " SHIM SPACE 2X8 SMOOTH SAWN RED VENEER SUPORT PER STRUCT. CEDAR LINTEL INSTALL I CEDAR LINTEL INSTALL w/1" FLUSH w/JAMB / CASING SEE TRIM DETAILS OVERHANG OVER JAMB / / 6X6 SMOOTH SAW CEDAR EACH SIDE-SEE 3A310 FOR LINTEL w/APROX. 2" j W3 WINDOW LINTELS SEALANT AND OVERHANG EACH JAMB i SEALANT AND BACKER ROD,TYP. SEALANT AND BACKER ROD,TYP. SEALANT AND BACKER ROD,TYP. SEALANT AND 0 BACKER ROD,TYP. JELD-WEN CLAD WINDOWS; BACKER ROD,TYP. SEALANT AND JELD-WEN CLAD WINDOWS; NOTED UNITS TO HAVE O NOTED UNITS TO HAVE INTEGRATED FIXED JAMB SEE DETAILS BACKER ROD,TYP.JELD-WEN CLAD WINDOWS; INTEGRATED FIXED JAMB SEE DETAILS SCREENS(SEE BLDG NOTED UNITS TO HAVE SCREENS(SEE BLDG ELEVATIONS) INTEGRATED FIXED JAMB SEE DETAILS ELEVATIONS) JAMB TYP. INTERIOR SCREENS(SEE BLDG INTERIOR ELEVATIONS) J AMB TYP STONE LE JAMB 11 WINDOW HEAD DETAIL @ CORTEN SIDING WINDOW HEAD DETAIL @ STONE VENEER 3 WINDOW HEAD DETAIL @ B&B SIDING N.T.S. N.T.S. N.T.S. EXTERIOR EXTERIOR EXTERIOR JELD-WEN CLAD WINDOWS; JELD-WEN CLAD WINDOWS; JELD-WEN CLAD WINDOWS; NOTED UNITS TO HAVE NOTED UNITS TO HAVE NOTED UNITS TO HAVE INTEGRATED FIXED SCREENS LINE OF SILL, BELOW SEE INTEGRATED FIXED SCREENS LINE OF SILL, BELOW SEE INTEGRATED FIXED SCREENS LINE OF SILL, BELOW SEE V (SEE BLDG ELEVATIONS) TRIM DETAIL SHEET (SEE BLDG ELEVATIONS) TRIM DETAIL SHEET (SEE BLDG ELEVATIONS) TRIM DETAIL SHEET SEALANT AND SEALANT AND SEALANT AND BACKER ROD,TYP. O SEALANT AND BACKER ROD,TYP. O SEALANT AND BACKER ROD,TYP. O SEALANT AND BACKER ROD,TYP. BACKER ROD,TYP. BACKER ROD,TYP. act STONE RUBBLE SILL W SILL SILL � CASING SEE TRIM DETAIL C> / MAHOGANY CASING SEE — SHEET CASING SEE TRIM DETAIL 0 Q STAINED 2X2 SMOOTH TRIM DETAIL SHEET \ 2X6 SMOOTH SAWN RED SHEET = DC SAWN RED CEDAR JAMB STONE RUBLE JAMB V A� CEDAR JAMB INSTALL V O INSTALL FLUSH w/SILL V A ` FLUSH w/SILL Q VYCOR PLUS,OR SIM. ON ALL %" SHIM SPACE VYCOR PLUS, OR SIM. ON ALL \ \ \' Y2" SHIM SPACE VYCOR PLUS, OR SIM. ON ALL Y2"SHIM SPACE SIDES OF OPENING W/30# SIDES OF OPENING W/30# V A SIDES OF OPENING W/30# J FELT OVERLAY FELT OVERLAY FELT OVERLAY\, PER STRUCT. \ II 2X KING STUD II PER STRUCT. BLDG PAPER; HOLD BACK V A V BLDG PAPER; HOLD BACK O 3"ALL SIDES OF WDW BLDG PAPER; HOLD BACK A A A 3"ALL SIDES OF WDW PER MANUF. SPEC. TYP.CORTEN WALL 3"ALL SIDES OF WDW TYP. MASONRY WALL PER MANUF. SPEC. CONST. SEE DETAIL PER MANUF. SPEC. \ CONST. SEE DETAIL TYP. B&B WALL CONST. 7-A501 2-A501 SEE DETAIL 3-A501 INTERIOR C> INTERIOR 10 WINDOW JAMB DETAIL @ CORTEN SIDING 6 WINDOW JAMB DETAIL @ STONE VENEER Z IN JAMB DETAIL @ B&B SIDING III N.T.S. N.T.S. N.T.S. EXTERIOR EXTERIOR EXTERIOR JELD-WEN CLAD WINDOWS; JELD-WEN CLAD WINDOWS; NOTED UNITS TO HAVE NOTED UNITS TO HAVE P R O J E C T INTEGRATED FIXED SCREENS JELD-WEN CLAD WINDOWS; INTEGRATED FIXED SCREENS NOTED UNITS TO HAVE D R A W N B Y (SEE BLDG ELEVATIONS) (SEE BLDG ELEVATIONS) INTEGRATED FIXED SCREENS LENTIL TRIM JAMB (SEE BLDG ELEVATIONS) SEALANT AND SEALANT AND JAMB SEALANT AND DATE : 05.13.13 "ri BACKER ROD,TYP. BACKER ROD,TYP. BACKER ROD,TYP. PREPARED SILL PAN W/END O PREPARED SILL PAN W/END O PREPARED SILL PAN W/END O DAMS PER MANUF. SPEC. DAMS PER MANUF. SPEC. DAMS PER MANUF. SPEC. R E V I S I 0 N S JAMB SEALANT AND SEALANT AND SEALANT AND PERMIT 01.30.01 TRIM BACKER ROD,TYP. BACKER ROD,TYP. BACKER ROD,TYP. WINDOW TYP. i CASING; SEE TRIM DETAIL CASING; SEE TRIM DETAIL CASING; SEE TRIM DETAIL CD #1 10.23.01 2X2 SMOOTH SAWN RED SHEET FOR SHEET FOR 2X6 SMOOTH SAWN RED SHEET FOR RE-ISSUE 05.13.13 CEDAR SILL w/DRIP KERF CEDAR SILL w/DRIP KERF SLOPE TOPMIN.1/$" __ __ SPECIFICATIONS SPECIFICATIONS SLOPE TOP MIN.%$" / SPECIFICATIONS VYCOR PLUS OR SIM. / / / VYCOR PLUS OR SIM. BENEATH WDW; CONTIN. INTO %" SHIM SPACE RUBBLE SILL / / BENEATH WDW; CONTIN. INTO /" SHIM SPACE PREPARED SILL PAN PER / / Y2" SHIM SPACE PREPARED SILL PAN PER MANUF. SPECIF. / / / MANUF. SPECIF. VYCOR PLUS OR SIM. / WINDOW TYP. JAMB DRAIN SCREEN PER MANUF. / DRAIN SCREEN PER MANUF. TYP.CORTEN WALL BENEATH WDW; CONTIN. INTO / TRIM SPEC. PREPARED SILL PAN PER / / SPEC. VYCOR PLUS,OR SIM.ON ALL CONST. SEE DETAIL MANUF. SPECIF. / VYCOR PLUS, OR SIM. ON ALL SIDES OF OPENING W/30# / 7-A501 SIDES OF OPENING W/30# TYP. B&B WALL CONST. FELT DRAIN SCREEN PER MANUF. / / TYP. MASONRY WALL FELT SEE DETAIL 3-A501 SPEC. / BLDG PAPER; HOLD BACK CONST. PAPER; HOLD BACK SILL TRIM CONST. SEE DETAIL 3"ALL SIDES OF WDW ( D VYCOR PLUS, OR SIM. ON ALL / / 3"ALL SIDES OF WDW PER MANUF. SPEC. INTERIOR SIDES OF OPENING W/30# PER MANUF. SPEC. FELT WINDOW DETAILS INTERIOR WOOD SIDING TYP. BLDG PAPER; HOLD BACK BOARD AND BATTEN 3"ALL SIDES OF WDW SIDING TYP. PER MANUF. SPEC. 13 EXTERIOR WINDOW DETAILS @ CORTEN SIDING 9 WINDOW SILL DETAIL @ CORTEN SIDING 5 WINDOW SILL DETAIL @ STONE VENEER 1 WINDOW SILL DETAIL @ B&B SIDING A603 N.T.S. N.T.S. N.T.S. N.T.S.