Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B13-0165 CUT SHEETS.pdf
R & H MECHMICAL "People.er ProdvctkY&wca4'I1000*It0 S�bs�rm9c lnsulalion Board 7 Urosion RerisW SImed Grairirrnef 4 v R Sefti placedz WA Grornmel � * `tee► �:'i � flange imbeked Base Loaf firtish Coal �`-- 0825A Chambers Ave./P.O. Box 810 Eagle,Colorado 81631 Phone: 970-328-2699/Fax: 970-328-0234/Email: into @randhmechanical.com Website: www.randhmechanical.com AAMITSUBISHI k ELECTRIC M-SERIES COOLING & HEATING 36,000 • • HEAT-PUMP SYSTEM Job Name:Swig Residence Location:Living Room Date:5/14/2013 Purchaser:R & H Mechanical LLC Engineer:N/A Submitted to:HOA/Town of Vail For *Reference N■Approval ❑■Construction System Designation:Living Room AC Schedule No.:Living Room AC $ Indoor Unit:MSZ-D36NA-8 Wireless Remote Controller Outdoor Unit:MUZ-D36NA-1 GENERAL FEATURES • Catechin and anti-allergy enzyme filters for high air-purification capabilites • Updated sleek,compact indoor unit design • Remote-controlled wide airflow enables ideal horizontal air distribution • Self-check function—onboard diagnostics • Advanced microprocessor control • Auto restart following a power outage • Hand-held Wireless Remote Controller • Anti-allergy Enzyme Filter • Limited warranty:five years parts and seven years compressors ACCESSORIES Outdoor Unit ❑ Drain Socket Assembly(MAC-811 DS) Indoor Unit ❑ Condensate Pump(230V,S13100-230) Controller Options • Wireless Remote Controller Kit(MHK1)* • Portable Controller(MCCH1)* ❑ Outdoor Air Sensor(MOS1)* *See Submittal for information on each option. • Wired Wall-mounted Controller (PAR-21MAAU requires MAC-3331F) • System Control Interface(MAC-3331F) Specifications are subject to change without notice. ©2013 Mitsubishi Electric US,Inc. SPECIFICATIONS: 1 • • • 1 • Cooling* Indoor Unit Rated Capacity... . . ... . . . .. .. . . . . . .. . ..... ...33,200 Btu/h MCA.. . ..... . ............. .. . ...... ........ . ...... . 1 A Minimum Capacity . .. . .. . ...... . . . .... . . ... ... .9,800 Btu/h Blower Motor(ECM).. . . .... . ...... ........ ... ... 0.76 F.L.A. SEER. . . .. ... . . . . .. .... .... . . . . . .. ... . . . . ..14.5 Btu/h/W Airflow Total Input.. .. . .. .. .. . .. . ... .. . .. ...... . ..... . ..4,360 W Cooling(Lo-Med-Hi-Powerful) 389-639-848-887 Dry CFM Heating at 47°F* 350-576-763-798 Wet CFM Rated Capacity... ... ... . ..... . . ......... .....35,200 Btu/h Heating(Lo-Med-Hi-Powerful) .445-639-848-887 Dry CFM Minimum Capacity .... .. . . . ... . .. ...... . ..... . .8,700 Btu/h HSPF . .. ............. . . ............... ......8.2 Btu/h/W Total Input.... ..... ... .. . . .... . .. . ..... .. . ... . .. 3,840 W Sound Pressure Level Heating at 17°F* Cooling(Lo-Med-Hi-Powerful) . . ..... 32-42 -49-51 dB(A) Rated Capacity... . . . . .. . . . . .. . . . . . . . . .. . . . ...21,800 Btu/h Heating(Lo-Med-Hi-Powerful).. ..... 34-42-49-50 dB(A) Maximum Capacity... ....... ... ... .... .... .. ..22,800 Btu/h DIMENSIONS UNIT INCHES/MM Maximum Total Input . . .. . . .. .. . .. . .. . . .... . ... ... 3,000 W W 46-1/16/1,170 D 11-5/8/295 *Rating Conditions per AHRI Standard H 14-3/8/365 Cooling Indoor:80°F(27°C)DB/67°F(19°C)WB Cooling Outdoor:95°F(35°C)DB/75°F(24°C)WB Weight . .. . ........... . . . ... . ... . Munse... .40 lbs. / 18 .2 Heating at 47°F Indoor:70°F(21°C)DB/60'F(16°C)WB External Finish. .. . .. . ... .. . .. . .... Munsell . . 1.OY 9.2/0.2 Heating at 47°F Outdoor:47°F(8°C)DB/43°F(6°C)WB Field Drainpipe Size O.D.. ... . . . . ...... . . .... ...../ .Wireless mm Heating at 17°F Indoor:70°F(210C)DB/60°F(16°C)WB Remote Controller . ..... . ... ... .... ........ . .... ..Wireless Heating at 17°F Outdoor:17°F(8°C)DB/15°F(9°C)WB Outdoor Unit ELECTRICAL REQUIREMENTS Compressor .. . ..... . ... .. .. . . . . . . DC Inverter-driven Rotary Power Supply.... . .. ...... . .... ..208/230V,1-Phase,60 Hz MCA. .. .. .. ...... .. .... .. . .. ... ......... . ... ... .. . 21 A Breaker Size.. ......... . . .. . . . . .. . .. . . . .... ... .. . ...25 A Fan Motor(ECM) ... .. .... . . ..... .. .... . ... ..... 0.93 F.L.A. Sound Pressure Level Voltage Cooling. . . ... ... ... ... . .. . . .... ... ... . ..... . ...56 dB(A) Indoor-Outdoor S1-S2 ........ . .. . .. . .. .. .. .AC 208/230V Heating... ............ .. ... .... ... . .. . ..... . .. .57 dB(A) Indoor-Outdoor S2-S3 ..... . .............. .... . . .DC t24V Indoor-Remote Controller. ... .. . .. ... ...... ...MHK1 DC 3V DIMENSIONS INCHES/MM PAR-21MAAU DC 12V W 33-1/16/840 PAR-FL32MA DC 3V D 113/330 OPERATING RANGE H 33-7/16/849 Indoor Intake Air Outdoor Intake Air Weight ... ... .. .. ... .. ..... . .... ......... .141 lbs. /64 kg Temp. Temp. External Finish .. .. .. . ..... . .. .. .. ....Munsell No.3Y 7.8/1.1 Maximum 93°F( )WB 115°F(46°C)DB Refrigerant Type.. . .. . ..... . ........... . ..... .... .. R41 OA 23°C Cooling ° ° Refrigerant Pipe Size O.D. Minimum 6 F(19 C)DB 14°F(-10°C)DB Gas Side ............. .. . ..... . ........ .. 5/8"/15.88 mm 57F14CW6 80°F(27°C)DB 75°F(24°C)DB Liquid Side..... . ..... . . .. .. .. .... . .. . ... . . 3/8"/9.53 mm Maximum Max.Refrigerant Pipe Length. . . . ... .. . .. ... ......100' / 30 m Heating 67°F 19°C WB 65°F 18°C WB Max.Refrigerant Pipe Height Difference ... . ... .. .. ..50' / 15 m Minimum 700 F(270 C)DB 140 F(-100 C)DB Connection Method ..... . .... .. .. . . . .......... .. . ...Flared 60 F 16 C WB 13 F A A C WB Notes: Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc. DIMENSIONS: 1 . 1 a MSZ-D36NA-8 45-1/2 Unit: Inch 2-11/16 Indoor unit 411/16 _� r 46.1/16 2 a- 20.71e 17-11/18 5-3/6 115/8 1/4 well hole a3 �� Installation late 25/16 piping �Irlr^ n 2-15118 33.11118 9-1/2 ■ R @gUlfBd$p8C@(indoor Unit) _ wireless remote controller 11-1111111 W mm 1 Dreln hose 1 Air out �7re � g ■ Piping Insulation Liquid lere 031819.11116 01.1/4 0.0. (Flared connection 0318) 09116 I.0. Gas Una 05/816-7/8 01-15/16 0.11 43 to«mva 639«mae (Joint connection 0518) 01-114 in ° Joint 0518 01-15116 0.11 For left;left,back;or left, (Flared connection 0518) ol-114111 bottom piping(using spacer):5-1/8 or more Drein hose Insulation 01.1/8 Connected pait 09116 0.4 MUZ-D36NA-1 Unit:Inch REQUIRED SPACE Open as a rule 20 Inch or more if the front and both sides are open 20-9/32 0,110 Wet 11-25/32 &W , 4 Inch or more / it 1-5/16, 2-9/32 \ 8 Inch or more ff there are obstacles �r to both sides Au 1-5/1,11/16 lift 3-1/16 Open as a rule 'tea 33-ins 3-3/LS 20 Inch or more if the back, 25/3 both sides and top are open O a _ 6u :S/l fftMITSUBISHI ELECTRIC ■ COOLING & HEATING _ Live Better AHRI Stmdud 2101240 T US 1340 Satellite Boulevard ,Mike traTao Suwanee,GA 30024 Intertek Tele:678-376-2900-Fax:800-889-9904 Toll Free:800-433-4822 www.mehvac.com FORM#MSZ-D36NA-8—MUZ-036NA-1-201304 Specifications are subject to change without notice. 0 2013 Mitsubishi Electric US,Inc. AkMITSUBISHI k ELECTRIC WAL11M. COOLING & HEATING Split-ductless A/C and Heat Pumps MULTI-INDOOR Job Name:Swig Residence Air-Conditioning Location:Grade Date:5/14/2013 Purchaser:R & H Mechanical LLC Engineer:NA Submitted to:HOA/Town of Vail For *Reference *Approval *Construction System Designation:(2) Beds Outdoor AC Unit Schedule No.:(2) Upper Beds AC Outdoor Unit GENERAL FEATURES Electrical Requirements • Compact side discharge outdoor Power Supply. ..... . ..... . ... .. . .208/230V, 1-Phase,60 Hz unit p 9 Recommended Fuse/Breaker Size. . ..... . ..... . . .. ......20 A • Wireless or wired remote MCA. .... .. . ... .. . ..... ...... . ...... .. . .. . . . . . .. . 15 A r�nr controller,depending on the Voltage indoor units used Indoor-Outdoor S1-S2 . .. . .. . .. . ..... . . .....AC 208/230V •Quiet operation—both indoor and Indoor-Outdoor S2-S3 ... . .. . .. . ...... .. . .....DC 12-24V outdoor units •Automatic fan speed control 1 OPERATING RANGE •Auto restart following a power 11 ] IndoorintakeAirTemp. Outdoor Intake Air Temp. Outage Self-check fu nction—integrated Cooling Maximum 95°F(35°C)DB,71°F(22°C)VtB 115°F(46°C)DB • ' • diagnostics Minimum 67 1F(19°C)DB,57°F(14°C)WS 14°F(-10°C)DB •Advanced microprocessor control Outdoor Unit:MXZ-2B20NA-1 Maximum 80°F(27°C)DB,67°F(19°C)WB 75°F(24°C)DB,65°F(18°C)WB •Limited warran :five ears on arts and Heating tY Y P Minimum 70°F(21°C)DB,60°F(16°C)W13 6°F(14°C)DB,5°F(-15°C)W8 defects and seven years on compressors Compressor .... . ... .. . .... . .. DC Inverter-driven Twin Rotary OPTIONAL OUTDOOR UNIT ACCESSORIES Fan Motor... . ............ . . ..... . ... . .. ...... 0.96 F.L.A. ❑ Air Outlet Guide(MAC-889SG) Sound Pressure Level 11 3/8"x 1/2"Port Adapter(MAC-A454JP;for use with Cooling(Non-ducted/Ducted)... .... . ......... . ... . .49 dB(A) 15,000 Btu/h Indoor units) Heating(Non-ducted/Ducted).. . .. .. .. .. . .. . .. . .... . 51 dB(A) Cooling* DIMENSIONS INCHES/MM Rated Capacity(Non-ducted/Ducted)...18,000 Btu/h/20,000 Btu/h W 33-1/16/840 Minimum Capacity(Non-ducted/Ducted) . .7,800 Btu/h/7,800 Btu/h Total Input(Non-ducted/Ducted). . ...... . .....1,440 W/2,190 W D 13/330 Heating at 47°F* H 27-15/16/710 Rated Capacity(Non-ducted/Ducted). . .22,000 Btu/h/22,000 Btu/h Weight .. . ... .. . . .. .. . . .... ... . ........ . ..130 lbs./59 kg Minimum Capacity(Non-ducted/Ducted) . .8,500 Btu/h/8,500 Btu/h External Finish .. ......... . .. . . . . .. . .Munsell No. 3Y 7.8/1.1 Total Input(Non-ducted/Ducted).... .. ..... ...1,650 W/1,780 W Refrigerant Type.. ......... .. .... ... ... .. . .. ...... R41 OA Heating at 17°F* Refrigerant Pipe Size O.D.—Two Ports Rated Capacity(Non-ducted/Ducted)..12,500 Btu/h 112,500 Btu/h Gas Side. .... . . .. .. .. .. . ..... . . . . .. . . A,B:3/8"/9.52 mm Total Input(Non-ducted/Ducted). .. ....... . . .1,350 W/1,430 W Liquid Side .... . ..... ..... .... ....... ..... .1/4"/6.35 mm *Rating Conditions(Cooling)-Indoor 80°F(27°C)DB/67°F(19°C)W3.Outdoor 95°F(35°C) Max.Refrigerant Pipe Length.. . .. ....... .. ... ....164'/50 m DB/75°F(24°C)WB. Max.Piping Length for Each Indoor Unit........ . ....82'/25 m (Heating)-Indoor 70°F(21°C)DB/60°F(161C)WB.Outdoor 47°F(8°C)DB/43°F(6°C)WB. Refrigerant Pipe Height Difference (Heating at 17T)-Indoor 70°F(21°C)DB/601F(16°C)WB.Outdoor 17°F(-B°C)DB/15°F Max.. g (-9°C)WS, If Indoor Unit is Above Outdoor Unit .. . ....... . .... 49'/15 m If Indoor Unit is Below Outdoor Unit... . ...... . . .. .. 33'/10 m (For data on specific indoor units[all ducted,all non-ducted,and both ducted Connection Method . ..... . .. ... . . ... .. . .. ... . ... .. .Flared and non-ducted]combinations,see the Technical and Service Manuals.) COMPATIBLE INDOOR UNITS Horizontal-ducted Indoor Units: SEZ-KD09,12,16NA4 Ceiling-cassette Indoor Units: SLZ-KA09,12,15NA MXZ-2B20NA-1 ENERGY EFFICIENCIES Indoor Unit Type SEER EER HSPF COP @ COP @ 47°F 17°F Wall-mounted Indoor Units: Non-ducted MSZ-GE06,09,12,15NA-8 09+09 18.0 12.5 8.9 3.91 2.71 Ducted and 16.75 10.8 8.7 3.77 2.64 Non-ducted Floor-standingg Indoor Units: Ducted t ? MFZ-KA09,12NA (09+12) 15.5 9.10 8.5 1 3.62 1 2.56 Wall-mounted Indoor Units: MSZ-FE09,12NA-8 IV®R �R Refer to the separate submittal forms for the SEZ,SLZ,MSZ,and MFZ Indoor Units. ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. r• 6-9/18• 19.11/16" e-2113z• Unit' Inch 93118' 11-11/32• O—Al \ r 70 BMeAUIrA�o b � � S 3•d(15118')Drain H°le � 13/32'•13/18 Oval Hole (Foundation Bak M10) 33.1/16' 7.718' 13/18' 13' 1/2' sdna'wnd,ea eaes Comaran ro 2518 b 8 " 11c .F am} tnv a 1101 0111'rwRE uo UN } GAS d • } A 0A.4 113/4' t29/32' rO 1. 1.Installation space Note:Leave both sides ° free of obstruction. More than 3-15/16' ® Grounding tenninel Conduit cover More than 19-11/16"k � Lock nut Connector Note:Leave overhead free of obstruction. _ More than 3-15/18'/ o More thanl3-2582' More than 19.11/16• 2.Service space 6 a ro o 71 More than 3-15/16'j 1 SERVICE SPACE More than 13-2582' More than 13 25132" MITSUBISHI Ilk . , Ak ELECTRIC CERTIFIED. COOLING & HEATING Live Better Lin"Small HP Rl S d 211)(240 T U$ 3400 Lawrenceville Suwanee Rd uaTeo Suwanee,GA 30024 Intertek Tele:678-376-2900•Fax:800-889-9904 Toll Free:800-433-4822(#3) www.mehvac.com FORM#MXZ-2B20NA-1 for Multiple Indoor Unit Styles-201108 Specifications are subject to change without notice. ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. ArtMITSUBISHI ELECTRIC W.SUIR COOLING & HEATING Split-ductless A/C and Heat Pumps SUBMITTAL • : iii c • -INDOOR • MULTI.ZONE HEAT-PUMP SYSTEMS Job Name:Swig Residence Air-Conditioning Location:(2) Upper Beds I Date:5/14/2013 Purchaser:R & H Mechanical LLC Engineer:N/A Submitted to:HOA/Town of Vail For *Reference ❑■Approval ❑■Construction System Designation:Upper Bedrooms Indoor Units Schedule No.:(2) Upper Beds Indoor Units GENERAL FEATURES • Wall-mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit • Quiet operation • Choice of fan speeds:Quiet,Low,Medium,High,and Super High Auto fan speed control also included • Hand-held Wireless Remote Controller • Indoor unit powered from outdoor unit using A-Control -- • Auto restart following a power outage _ • Base heater is available as an option Indoor Unit:MSZ-GE12NA-8 • Anti-allergy Enzyme Filter • Limited warranty:five years on parts and defects and seven years Voltage on the compressor Indoor-Outdoor S1-S2 ........... . ...... ..... . AC 208/230V Indoor-Outdoor S2-S3 ... ... ..... . .... .... . ..... .DC 12-24V OPTIONAL ACCESSORIES Indoor Unit Fan Motor.... . .. ... . ... .. . .. . . ... ... .. . .. . ..... .0.76 F.L.A ❑ Condensate Pump(230V;S13100-230) Airflow(Quiet-Lo-Med-Hi-Super Hi) Controller Options Cooling.......................145-170-237-321-399 Dry CFM • Wireless Remote Controller Kit(MHK1)with Remote Controller 109-134-201 -286-364 Wet CFM (MRCH1),Wireless Receiver(MIFH1),and cable(MRC1)* Heating . .... .. .... ...... . ... 145-170-237-321 -406 CFM • Setback down to 50*F when used with MRCH1 Remote • Portable Central Controller(MCCH1;for use with Wireless Remote Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Controller Kit MHK1)* Cooling ....... ...... . ...... .. ... 19-22-30-37-45 dB(A) • Outdoor Air Sensor(MOS1;for use with Remote Controller(MRCH1), Heating .. . .... . ..... ............ 19-22-30-37-43 dB(A) Wireless Remote Controller Kit(MHK1)and Portable Central Controller(MCCH1)*Controller(MCCH1)* DIMENSIONS UNIT INCHES/MM *See Submittal for information on each option. • Wall-mounted Wired Remote Controller W 31-7/16/799 (PAR-21 MAA requires MAC-3971F) D 9-1/8/232 • MA Contact Terminal Interface(MAC-3971F) H 11-5/8/295 • M-NET Control Adapter(MAC-3991F) • Remote Temperature Sensor(M21-JKO-307) Weight.. ..... . .......... ....... ... .........22 lbs./10 kg • Lockdown Bracket for Hand-held Controller(RCMKP1CB) External Finish ...... ........ ........ Munsell No. 1.OY 9.2/0.2 Field Drainpipe Size O.D..... ................ .. 5/8"/15.88 mm Cooling Capacity*..... ... . .... . . .. . ..........12,000 Btu/h Refrigerant Type.... . .... . .. . . . .. . .. . ......... .... .. .R41OA Heating Capacity*. .. .. . . .. .. . .. ......... . ... .14,400 Btu/h Refrigerant Pipe Size O.D. *Rating Conditions(Cooling)-Indoor:80OF(270C)DB,670F(190C)WB;Outdoor 95oF Gas Side. ....... .. . . ......... 3/8"/9.52 mm (35oq DO,75DF(240C)WB. '''' ' '''''' ' (Healing at47*F)-Indoor.70o F(210 C)OB,60o F(16o C)WB;Outdoor 47oF(8*C)DB,43OF(6°c)WS. Liquid Side.. . .. . . . ...... . . . . .. ... .. . ....... 1/4"/6.35 mm (For data on specific indoor units[all ducted,all non-ducted,and both ducted Connection Method ..... . ...... .. ... . .. ...... ....... .Flared and non-ducted]combinations,seethe MXZ-B Technical and Service Manual.) Electrical Requirements MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS Power Supply... . .. . .. . ......... .208/230V, 1-Phase,60 Hz MCA.. . .. . ... .. . . . . .. . . . ... . .. .. . . .. .... ...... .. . . 1 A MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE: •Ducted Indoor Units: SEZ-KD09,12,15,18NA4,PEAD-A24AA4 I•�; . •Nonducted Indoor Units: MSZ-GE06,09,12,15NA,1 8NA-8,24NA, --o MSZ-FE09,12NA-8,18NA,MFZ-KA09,12,18NA, PCA-A24KA4,SLZ-KA09,12,15NA,and PLA-Al 2,18,24BA4 •A combination of both Ducted and Nonducted Indoor Units Refer to the separate submittal forms for the MSZ-GE SEZ and PEAD-A24AA4 R MSZ-GE,MSZ-FE,MFZ-KA,SEZ-KD,SLZ-KA, MULTI-ZONE OUTDOOR UNIT PEAD,PCA,PLA Indoor Units,and MXZ Outdoor Units. anww 1=1 # MSZ-FE ' xro r tf( R MFZ-KA PCA-A24KA4 SLZ and PLA-Al2,18,24BA4 ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. f0 6-1/8 B-1/8 Insulation e1-318 O.D Llquld line 01/419-11/16(Flared connection 0114) pal Gas Ilne " ArtMITSUBISHI ELECTRIC COOLING & HEATING