No preview available
HomeMy WebLinkAboutDRB130162 Project Name:US BANK BLDG AIR HANDLER DRB Number: DRB130162 Project Description: ADDITION OF ROOF TOP UNIT FOR TENANT FINISH REMODEL ON THIRD FLOOR. Participants: OWNER VAIL CLINIC INC 05/15/2013 PO BOX 40000 VAIL, CO 81658 APPLICANT VAIL CLINIC INC 05/15/2013 PO BOX 40000 VAIL, CO 81658 CONTRACTOR VAIL VALLEY MEDICAL CENTER 05/15/2013 Phone: 970-479-7199 RYAN MAGILL 181 W MEADOW DR VAIL CO 81657 License: C000003606 Project Address:108 S FRONTAGE RD W VAILLocation: US BANK BUILDING UNIT 206 Legal Description:Lot: D-2 Block: Subdivision: Vail Village Filing 2 Parcel Number:2101-064-0800-1 Comments:See Conditions BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 05/23/2013 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner:Joe Batcheller DRB Fee Paid: $250.00 ******************************************************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 05-15-2013 at 13:37:07 05/15/2013 Statement ******************************************************************************************** Statement Number: 8130000602 Amount: $250.00 05/15/201301:36 PM Payment Method:Credit Crd Init: DR Notation: VISA RYAN MAGILL ----------------------------------------------------------------------------- Permit No: DRB130162 Type: DRB-Minor A1t,Comm/Multi Parcel No: 2101-064-0800-1 Site Address: 108 S FRONTAGE RD W VAIL Location: US BANK BUILDING UNIT 206 Total Fees: $250.00 This Payment: $250.00 Total ALL Pmts: $250.00 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ DR 00100003112200 DESIGN REVIEW FEES 250.00 ----------------------------------------------------------------------------- I D 2U13 Department of Community Development MAY 15 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 TOWN OF VAIN www.vailgov.com Development Review Coordinator Application for Design Review Minor Exterior Alteration General Information: This application is required for all proposals involving minor changes to buildings and site improvements, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information-Town Code Online. All projects requiring design review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Fee: $250 for Multi-Family/Commercial $20 for Single Family/Duplex ❑ Single Family ❑ Duplex ❑ Multi-Family Commercial Description of the Request: ( nSd-Q�� GJ►Y �l.IW eC � �! t .� Fog- wogy, -R)EtNG i-)oA-jc Physical Address: b s �,� ,�q,t (ed Parcel Number: .Z b �"� O rf D O I (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: 1)4. Ua��P- is `� �w�✓ Mailing Address: ?, 6. Z n%t Y�V o Van I Cp (a l G r k Phone: 9704-06 2 5/s: Owner's Signature: Primary Contact/Owner Repre ntativ A Moe, Mailing Address: Q tA&nt-t_nr-- Phone: g-70. 9.0 D D!o 6 E-Mail: Fax: X70, y7 f. S�y� For Office Use Only: Cash C: Visa/MC Last 4 CC# t yl� Exp. Date: Auth # Og63C Check# Fee Paid: 01sex0c) Received From: }RYAN MAta/LL Meeting Date: DRB No.: 'D�g Planner: Project No: PR5 (3-O Iq S Zoning: Land Use: Location of the Proposal: Lot: _Block: Subdivision: VA I L VtLt.r4GG Fir� Series 10 (6.5-12.5 Ton) Page 1 Johnson �� Controls Single Package R-410A Air Conditioner Project Name: Vail Valley MS Unit Model#: J06ZHS15Q2BZZ5 Quantity: 1 Tag#: RTU-1 System: J06ZHS15Q2BZZ5 Cooling Performance Total capacity 69.1 MBH Sensible capacity 46.0 MBH Refrigerant type R-410A Efficiency(at AR I) 11.50 EER y l Integrated eff.(at ARI) 12.60 IEER 1 Ambient DB temp. 95.0 °F Entering DB temp. 76.0 °F Entering WB temp. 57.0 °F ..• Leaving DB temp. 49.9 °F Leaving WB temp. 43.0 °F Part load efficiency 13.7 IPLV Power input(w/o blower) 5.32 kW Sound power 83 dB(A) Gas Heating Performance Entering DB temp. 40 °F Heating output capacity(Max) 97.9 MBH Supply air 2200 Heating input capacity(Max) 122.4 MBH 6.5 Ton Leaving DB temp. 95.5 °F • JCI Series 10 units are manufactured at an ISO 9001 registered facility and Air temp.rise 55.5 °F SSE 80.0 % each rooftop is completely computer-run tested prior to shipment. Stages 2 Unit Features Supply Air Blower Performance • Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours Supply air 2200 CFM Salt Spray Test(ASTM B-117 Standards) Ext.static pressure 1.0 IWG • Through-the-Curb and Through-the-Base Utility Connections Unit static resistance 0.11 IWG • Full perimeter base rails with built in rigging capabilities Blower speed 1323 RPM . Hinged Access Panels Max BHP of Motor(including service factor) 2.30 HP Duct location Bottom • Slide-Out Stainless Steel Drain Pan Motor rating 2.00 HP • Reciprocating Compressor Actual required BHP 1.28539 HP • Two Stage Cooling Power input 1.19 kW . Solid Core Liquid Line Filter Driers Elevation 8000 ft. . Microchannel Condenser Coil Drive type BELT Requires field-supplied drive true • Hot Gas Bypass • 150 MBH Output Stainless Steel,Two Stage Gas Heat Electrical Data • 2 HP High Static Belt Drive Blower Power supply 208-3-60 • Unit Ships with 4"Pleated Filters(MERV 13) Unit min circuit ampacity 36.20 Amps . Single Point Power Connection Unit max over-current protection 45 Amps • HACR Circuit Breaker/Disconnect(Sized for 208 Volts) Dimensions &Weight . Phase Monitor Hgt 42 in. Len 89 in. Wth 59 in. . Single Enthalpy Economizerw/Barometric Relief and Power Exhaust and Weight with factory installed options 1165 lbs. Hoods(Bottom Return Only) Clearances • Short Circuit Current:5kA RMS Symmetrical Right 12 in. Front 36 in. Back 36 in. Standard Unit Controller: Simplicity®Control Board To p 72 in. Bottom 0 in. Left 36 in. Safety Monitoring-Monitors the high and low-pressure switches,the Note. Please refer to the tech guide for listed maximum static pressures freezestats,the gas valve,if applicable,and the temperature limit switch on gas and electric heat units.The unit control board will alarm on ignition q\� failures,safety lockouts and repeated limit switch trips. BAS Controller • Metasys FEC-Bacnet MSTP with Discharge Air Sensor, Return Air,Outside Air Sensor,Air Proving Switch,and Dirty Filter Switch • VFD and Duct Pressure Sensor Factory Installed • VFD and Duct Pressure Sensor Factory Installed&Customer Supplied and Field Installed VAV Controller and Temperature Sensors Warranty • One(1)Year Limited Warranty on the Complete Unit • Five(5)Year Warranty-Compressors • Fifteen(15)Year Warranty on Stainless Steel Heat Exchanger Unitary Sales Tool 0.5.6.0 Information is subjectto change without notice.Check local codes. Printed 05/10/2013