HomeMy WebLinkAboutDRB130102 PEC130015 Plans ApprovedMATERIAL SYMBOLS: UNIT 630 RlAfAk 133 WILLOW PLACE ABBREVIATIONS: EARTH PLYWOOD ABV ABOVE L LENGTH AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH AP ACCESS PANEL LT LIGHT TROUGH POROUS FILL /DRAINAGE FINISH WOOD AC ACOUSTICAL LTL LINTEL ADD ADDENDUM LVR LOUVER ADJ ADJACENT MH MANHOLE ALT ALTERNATE MFR MANUFACTURE (ER) ALUM ALUMINUM MO MASONRY OPENING STONE MASONRY WOOD -ROUGH ARCH ARCHITECT (URAL) MTL METAL BSMT BASEMENT MAX MAXIMUM BRG BEARING MECH MECHANIC (AL) STRUCTURAL CONCRETE BLOCKING BVL BEVELED MC MEDICINE CABINET BIT BITUMINUOUS MEM MEMBRANE BLK BLOCK M METER (S) BLKG BLOCKING MM MILLIMETER (S) CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM BLDG BUILDING MIR MIRROR CPT CARPET (ED) MISC MISCELLANEOUS CSMT CASEMENT MULL MULLION BATT INSULATION C CAULK (ING) NAT NATURAL CLG CEILING NR NOISE REDUCTION CT CERAMIC TILE NOM NOMINAL CLR CLEAR NIC NOT IN CONTRACT RIGID INSULATION COD CARBON MONOXIDE DETECTOR NTS NOT TO SCALE COL COLUMN OPG OPENING CONC CONCRETE OPP OPPOSITE CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND STEEL /METAL AS NOTED CONST CONSTRUCTION OH OVERHEAD CONT CONTINUOUS PR PAIR CJT CONTROL JOINT PK PARKING CPR COPPER PVMT PAVEMENT CARPET CUST CUSTOM PL PLASTIC LAMINATE DT DRAPERY TROUGH PT POINT DTL DETAIL PSF POUNDS PER SQUARE FOOT DIM DIMENSION PSI POUNDS PER SQUARE INCH DR DOOR PL PROPERTY LINE DRW DRAWING QT QUARRY TILE DF DRINKING FOUNTAIN REF REFERENCE ELEC ELECTRIC (AL) REF REFRIGERATOR 1 1 EL ELEVATION (S) REIN REINFORCE (D), (ING) A4.00 A4.00 ELEV ELEVATOR REQ REQUIRED EQ EQUAL RES RESILIENT EXH EXHAUST REV REVISION (D), (ING) BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE EXT EXTERIOR RH RIGHT HAND FOC FACE OF CONCRETE R RISER FOF FACE OF FINISH R &S ROD AND SHELF FOM FACE OF MASONRY RD ROOF DRAIN 1 1 1 FOS FACE OF STUDS RDT RECESSED DRAPERY TRACK A4.00 A4.00 FIN FINISH (ED) RFG ROOFING FFE FINISHED FLOOR ELEVATION RM ROOM FE FIRE EXTINGUISHER RO ROUGH OPENING FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN DETAIL REFERENCE DETAIL REFERENCE FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING FP FIREPLACE SHH SHOWER HEAD MAIN 1 FPS FIREPROOFING, SPRAYED SHC SHOWER CONTROLS 100' -0" \kA4.00Y FLG FLASHING SM SHEET METAL FLR FLOOR (ING) SIM SIMILAR FD FLOOR DRAIN Sc SOLID CORE HEIGHT REFERENCE SECTION REFERENCE FTG FOOTING SPEC SPECIFICATON (S) FND FOUNDATION SQ SQUARE FBO FURNISHED BY OTHERS STD STANDARD FPHB FREEZE PROOF HOSE BIB ST STAIN FUR FURRED (ING) STL STEEL ROOM NAME GA GAGE, GAUGE SD STORM DRAIN 0 GALV GALVANIZED STIR STRUCTURAL QGC GENERAL CONTRACT (OR) TEL TELEPHONE REVISION REFERENCE GL GLASS, GLAZING TV TELEVISION ROOM NAME GYP GYPSUM BOARD THR THRESHOLD HB HOSE BIB T &G TONGUE AND GROOVE HDW HARDWARE TOS TOP OF SLAB HDR HEADER TOS TOP OF STEEL HTG HEATING TOW TOP OF WALL GRID W11 HVAC HEATING /VENTILATING /AC TB TOWEL BAR HT HEIGHT TR TRANSOM HC HOLLOW CORE T TREAD GRID BUBBLE WALL TYPE REFERENCE HM HOLLOW METAL TYP TYPICAL HOR HORIZONTAL LINO UNLESS NOTED OTHERWISE HWH HOT WATER HEATER VB VAPOR BARRIER 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD ID INSIDE DIAMETER VERT VERTICAL IBC INSTALLED BY CONTRACTOR VCT VINYL COMPOSITION 4 A81 2 11 INS INSULATE (D) (ION) WP WATER PROOFING 3 INT INTERIOR WWF WELDED WIRE FABRIC JC JANITOR'S CLOSET W WIDTH, WIDE INTERIOR ELEVATION REFERENCE WINDOW TAG KIT KITCHEN WDW WINDOW LAM LAMINATE (D) WO WITHOUT LAV LAVATORY WD WOOD LH LEFT HAND 33 DOOR TAG OWNER: Jorge Burillo Riva Ridge Unit 630 Vail, CO 81657 432.934.2747 CONTACT: Olga Burillo EMAIL: olgaburillo @gmail.com STN - / TILE MATERIAL BREAK CONTRACTOR: SIRE BUILDING ASSOCIATES, INC. P.O. Box 6376 Vail, CO 81658 970.845.6359 CONTACT: STEVE ELICKER EMAIL: sieve @srebuilds.com ARCHITECT: SUMAN ARCHITECTS P.O. Box 7760 AVON, COLORADO 81620 970.479.7502 CONTACT: MICHAEL SUMAN EMAIL: michael@sumanarchitects.com STRUCTURAL: T. BOYLE ENGINEERING, INC. 970.476.2170 CONTACT: TIM BOYLE EMAIL: boyleeng @gwestoffice.net GENERAL NOTES: RIDGE NORTH VAIL, CO 81657 01 DO NOT SCALE DRAWINGS 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE CONSTRUCTION CONTINUES IN THOSE AREAS. 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES AND CLOSET RODS. 06 O DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH ARCHITECT. 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS PROJECT, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT. 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE, 2009 EDITION. CODE COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. I THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY CUTTING, NOTCHING OR DRILLING OF ANY CAST -IN -PLACE CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL -TYPE TUBS. COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. MECHANICAL: RADER Engineering, Inc. P.O. BOX 8610 Avon, CO 81620 P: 970.845.7910 CONTACT: Bryan Houle EMAIL: BryanH @raderengineering.com GENERAL LOCATIONS OF NEW CONSTRUCTION ON BUILDING Approved by the Planning & Environmental Commission DRAWING INDEX: ARCHITECTURAL TOXIN OF VAIL 1'- By Warren Campbell at 11:23 am, May 16, 2013 A0.00 COVER SHEET A0.01 SITE PLAN A1.00 EXISTING GARAGE LEVEL A1.01 EXISTING FIRST FLOOR A1.02 EXISTING SECOND FLOOR A1.03 EXISTING MEZZANINE FLOOR A1.04 GRFA FLOOR PLAN SUMMARY A1.05 GRFA BELOW GRADE DEDUCTION A2.02 SECOND FLOOR DEMO PLAN A2.03 MEZZANINE FLOOR DEMO PLAN A2.04 ROOF DEMO PLAN A2.22 PROPOSED SECOND FLOOR PLAN A2.23 PROPOSED MEZZANINE FLOOR PLAN A2.24 PROPOSED ROOF PLAN X3.01 EXISTING WEST ELEVATION X3.02 EXISTING SOUTH ELEVATION A3.02 PROPOSED SOUTH ELEVATION X3.03 EXISTING EAST ELEVATION A3.03 PROPOSED EAST ELEVATION X3.04 EXISTING NORTH ELEVATION A3.04 PROPOSED NORTH ELEVATION Design Review Staff Approval TOWN OF VAIL By Warren Campbell at 11:23 am, May 16, 2013 DRAWING INDEX: ELECTRICAL E2.01 SECOND FLOOR ELECTRICAL PLAN E2.02 MEZZANINE FLOOR ELECTRICAL PLAN t 1i &1P 4115"1 �SF`�:i��l ■' 1 IGS'111 � J[ ��I ��' �rJl• Illwl Ie � (.1311 Iwo 1+ d7 ",ri. /P. '41 ;P �ll'1111L�1�1�� `�1 r - ,tP i0ll t "1° % � �" 111�71J1M,Ir,dlr� IN MOE II" �kr ■ ` ` y B r ` �� ■ �i.�liR� r..+■ . �.e..�.ar' ��f ii jr rY �j.:• y......r• ■. a... Indir lM■, ,.rw . 000�.������i��i' x001 •� 9r '° f ■i IYIll 0E0.- '1151 '�� IIPIMIGIICIIMGI!1'I'f1JA��Ck ELECTRICAL: VICINITY MAP ARCHITECTURAL ENGINEERING DESIGN GROUP, INC. 1900 WAZEE STREET, SUITE 255 DENVER, COLORADO 80202 P: 303.296.3034 CONTACT: Jeff Mullikin EMAIL: jmullikin @aedesign- inc.com i"� ■r.' 'y ■� �Y *- �iC.���1 31C IQ � +J 00P 1SO4 � �' { t l 112 ' ,3. G. w IF *�+■. +ill ��, t �. dR P -1F 11 �� II "1M(� „ &W, RIF HN.G O1!Ilnog,0`11i 111 I/ DATE: HOA SUBMITTAL 4.1.13 i. .�. ll ��� RECEIVED p - ��� 11M';I'�I "1� ��r• 1# By David Rhoades at 11:49 am, Apr 15, 2013 35.E r; JL kill ATI, PROJECT SUMMARY: Code: i'/ ;�/ .� P 1• International Building Code 2012 Occupancy: R -2 .r II 111,.,E Iis T` f Construction Type: TYPE V -A ;f Use: Residential Condo Special Attributes: Existing Fire Alarm System F � U` 4- u n J COPY RIGHT RESERVATION P r The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain, without limitation, all common law, statutory and other reversed rights, including the copyright hereof. No person, whether '.1 having come rightly into possession hereof or otherwise, �-" shall employ these documents on any other project, nor for additions to this Project nor for the completion of this Project by others, unless with the prior express written p■ 14 consent of the Architect and upon appropriate err 1 � 11, 1 ��1•i ,15 � +, • W' compensation to the Architect in an amount and kind satisfactory to the Architect. The Architect expressly R1II 20, 1 :000• claims all proprietary rights in the material which is issued 10 -,®„ 4I (.1, f;6' in confidence for design and /or construction purposes of ' �,�a��11�.� this Project as noted. These materials may not be `'�111# copied, modified, nor employed in any way without the 1-3°■ t�iP;�';�I`;'1 F;iF�ill_. specific prior written consent and permission of the .� {, ■t ;�I +�,�aF11 "' Architect. @ 2013 Michael Suman Architect, LLC. All rights reserved. O 0 V cc J O IL J 3 O O V J n J � a � 3 T a■ .J a LL1 � J m L� H Z LLI O a o J Z ; 0 ch V J � a _ ' � IA W O W V O � m lE c O cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 J2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: DRAINN: MDS PROJECT A- 1307 SHEET TITLE: COVER SHEET �[ilili] 1 o• ixirina� i�4aes.'tiMi:e +! >eT;irIM6i:Y+id 41199 HOHMAY 8 t R.* EAGLE—VAR P.0. BOX 1230 EDMAR9S, CR Sod 81932 970 iW9— 3(y Xoap _� Design Review Staff Approval TOWN OF V�AIL � By Warren Campbell at 11 :23 am, May 16, 2013 Approved by the Planning & Environmental Commission TOWN OF VAIL 1 By Warren Campbell at 11 :23 am, May 16, 2013 Notes i • 1) LATE OF SURVEY: 3/7/13 M ?) SURVET'oR im WDE no MNESIIFQ rm oR wDEP oDa SEARCH FOR AMENDED ER IHIN AiST g�A14115. OWIE P TITIi EN M=), F' ALT' 11NT AN AOCIlM7E ARD CURRF]iF STILE SFARCtf 11AY D�.D� 3) NOTICE ACCORDING TO COIORQO TAW YOU YUFT COMMENCE MY LEGAL ACTION BASED UPON ANY DEF= N TM SURVEY IAO1W IHM TEAR$ AFFOE YOU FOW O15COM SUCH DID=. N NO EVETW, MAY ANY TIO ACN RPM UPON ANY DEFECT M TM Fi LY BE LUL9A:NCED IAORE THAN TEN YEA1tS FROM THE DATE OF 7FE CERTMTION SHORN 4) SENRIIG4 AND DISTANCES MONO PROPERV LIES SHOWN HEREON ARE . AS 900 ON THE 9S MSIOH PLAT ONLY A BOUNDARY SURVEY MOULD BE NECESSARY TO DETERMINE THE TRUE DIM NS7016 OF THE LOT AND SE7IACKS, Wr M MAY VAMP FROM TIE PLATTED DI EESON& 5) TO SURVEY AND THE INFORMATION CONWOM HMON IS TE PROPERLY OF .. EAGLE VALLEY MIRVEYNO, NC. AND IS BTTENDED FOR THE 901E USE of THE ONGrRM. CLIENT OILY. ANY 115E OF OR YWViShiYt TO U, IS PROMBULD. a) ROM OF PROPERTY LIE LOCATO& FOUND HOIILAIFMB MA04 THE 80UIMTE MMY CORNER OF RIVA RIDGE (NORTH) CFNLETS AND T1E NORDNIFST CORNER OF SUMMERS LODGE CONOOMIA PA& 7) BIADNO SETBACK NMORWTDN B Nor PLATTED. PFwR To ANY Go= OR CONSTRUCTION WPA040 ENTS ON TM PROPERTY. TORN OF WF SHOULD BE ODNIACTED FOR ODR7tEGT BUILDING SETBACK MONATIpL 8) 10 OF blow ON LOT AT THE OF ST l"' SOLE FEATURE" MAY E)3bT BENEATH SNOW THAT ARE NOT Zr l"' TiS 6RAYIIiD. 9) POSTED ADORES& 133 GORE CREEC DRNE. 14)) RMDBO SUDAN YEAS IOCATIO) AND MEAMI D TO TRAM 40 VARIOUS MCI" 5 AND DBI00014S SI N SHOULD NEW BE RELm UPOII IMPROVENAETIT LOCATION CERTIFICATE I hereby At� cartlfy that this knpr nonl Laaetfen CertIlkets was prnparad far 99t Bnlrum _ it Is nowt to be railed lond Tor fhe �tahllehmaM�a of Ifan. ..P..- ordother future LnproMwnwrt Enae. U further thol Urs lmpravwnants on She obaw on tht• dot. 3/7 13 emxpt utAlty conn=01 are ppgg boundarfee of the parook o n ept as sheen, that tlrp .. upon the du ilmd prerNw by Tnyrow rents " ap eacae9l as kWkd*d. and Drat than b no o eosement Maaesh9 or burdenln9 onY Pof't t s M10hoo 1, ost J4. b` r�r Y�i '11 �i e1i •e Yea •,;.a�A. Approved by the Planning & Environmental Commission TOWN OF VAIl A By Warren Campbell at 11 :23 am, May 16, 2013 SUMMERS LODGE CONDOMINIUMS - Design Review Staff Approval - � LIGHT POLE OWN �� By Warren Campbell at 11 :23 am, May 16, 2013 20' EASEMENT PHONE 0 VAPED B — 171 4 — _�- 0 00 W _ / 109 .b sb, ° 0' 10' 20' 30' EDGE OF CONC WALK ♦ ♦ ♦ ♦ ♦ ♦ I J 1 3.7' W AT VAL 0 =48° 16'00" R= 125.26' L= 105.52' T= 56.12' BRG =S 17'38'1 4"W C LEN= 102.42' PHONE PIED CONC MH LID e / / ♦ A= 1 16 °29'00" R= 20.00' L= 40.66' T =32.31 ' BRG =N73 °31'30 "E C LEN = 34.01' r. EDGE OF PAVERS 17 °08'04 "E 7.50' L =31 °22'09" R= 136.02' L= 74.47' T= 38.19' BRG =N30 °57'54 "E C LEN = 73.54' O Ck a a 0 J O d 3 0 0 V J J J — a � 3 � M > M r Z� J Z M7 W {� LLIU) TM a W � 0 a o � a O j _ > O a v W O _ m OC � a � rc � cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E � U vi n � Q , a U i a E V) W r� l E a a a� Lo NO co 0 U L-1 N - �n ] O Ck a a 0 J O d 3 0 0 V J J J — a � 3 � M > M r Z� J Z M7 W {� LLIU) TM a W � 0 a o � a O j _ > O a v W O _ m OC � a � rc � cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC)2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: I"= 10'-0" DRAWN: MDS PROJECT A- 1307 SHEET TITLE: SITE PLAN A0.01 EXISTING GARAGE LEVEL Design Review Staff Approval Approved by the Planning & Environmental Commission A1.00 SCALE: 1/4" = 1' -0" TOWN OF VAIL By Warren Campbell at 11 :23 am, May 16, 2013�rli t By Warren Campbell at 11 :24 am, May 16, 2013 EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED V77 11 REF. E r N 1 Q , �U 1 �I I � 1 I U 1 O O E I � UNIT 620 PARKING UNIT 635 PARKING UNIT 640 UNIT 600 PARKING PARKING UNIT 625 PARKING UNIT 630 PARKING GUEST PARKING BICYCLE STORAGE 0 ® ET a a o a a o a a a 1 L0 0 d) 110 1 UNIT M 1 600 U W 1 1 o I 1 1 ENCLOSED 1 PATIO 1 D O 1 � O 3 1 a 0 0 0 I 1 �> > M STORAGE 1 O r o 1 z 1 O � z \ � J IL COMMON PARKING ® W U) 1 D 1 z W O O j STAIR 1 z > o�� D 1 0 z �c W v 0 1 c m 1 � �o 1 >_ o oC � 1 ENCLOSED 1 PATIO COMMON 1 D D I 1 1 1 I 1 GUEST UNIT 615 UNIT 645 UNIT 610 UNIT 605 BOILER 1 UNIT ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 PARKING PARKING PARKING PARKING PARKING LAUNDRY ROOM 1 605 0 0 0 1 O El ® TOV PEC VARIANCE 4.15.13 I 1 O O I 1 I 1 I 0 I I 1 I I I 1 I 0 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1'-0" REF. DRAWN: MDS PROJECT A- 1307 I SHEET TITLE: EXISTING PLAN I AlmOO Design Review Staff A roval pp 01! Approved by the Planning & Environmental Commission 01? EXISTING A1.01 SCALE: 1/4" = 1' FIRST FLOOR P LAN By Warren Campbell TOWN OF VAllL at 11 :24 am, May 16, 2013 TOWN OF VA By Warren Campbell at 11:24 am, May 16, 2013 -0" EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED REF. REF. b � DINING ROOM KITCHEN 0 EXTERIOR EXTERIOR KITCHEN DINING ROOM r N n U Q °' s U PATIO PATIO o 0 0 0 0 1 • ue E q� ' 0 BATH T� BATH TWO 0 ,a LO UNIT 615 UNIT 60 Ln BEDROOM ' BEDROOM BEDROOM BEDROOM u W�� TWO THREE THREE TWO on LIVING LIVING ROOM ROOM D � D EXTERIOR EXTERIOR PATIO PATIO M � � O d BEDROOM ENS / ENO O . o 0 3 v ONE D BATH BATH 3 ONE D c,r------ - - - - -- ------ - - - - -- 1 ------ - - - - -- — ------ - - ONE - -�0 0 Q > M c� r z ® DN ® o EXIT EXIT J STAIR 1 STAIR 2 m ® ® N Lu~ DN z W a rr _ z— o CLOSET v J u 6 i F-1 z v a iiiiiiiiiji STAIR D J m \ / > O rc j ' COMMON EXTERIOR ' CORRIDOR EXTERIOR PATIO PATIO ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 UNIT ® O O ' � O O UNIT TOV PEC VARIANCE 4.15.13 610 � —101 625 D D =;Dra o�o i I D EXTERIOR PATIO EXTERIOR PATIO D KITCHEN KITCHEN 0 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" REF. REF. DRAWN: MDS PROJECT #: 1307 SHEET TITLE: EXISTING PLAN A Imol - Approved by the EXISTING SECOND FLOOR PLAN Design Review Staff Approval Planning & Environmental "VAIL Commission A1.02 SCALE: 1/4" = 1' -0" B y Warren Campbell at 11:24 am, May 16, 2013 By Warren Campbell at 11:24 am, May 16, 2013 TOWN OF f! TOWN OF VA+ L � � � � EXISTING 1 HR RATED SEPARATION WALLS TO BE MAINTAINED REF. BASEBOARD HEATER `� � y F_ n U I— — _J DECK MASTER I DECK KITCHEN DINING ROOM R s �^ E TAE OR PAM SITTING I FOR PAM ® KITCHEN DINING \ ROOM \ ® wP1 BEDROOM TWO ue ®` \ O MASTER _ 3 \ \ BATHROOM BATH THREE R ° LO a� WD BURNING\ UNIT 60 \ 0 I BEDROOM D UNIT 640 GAS cc Q FIREPLACE \ \ THREE FIREPLACE W \ \ O \ MASTER BEDROOM ! CLOSET LIVING .- \ \ � \— BEAM ABOVE O THREE ROOM O \ O POWDER 1 0 \ V I W/D DECK EXTtRibR \ \ • O BUILT -IN DECK EXMJR PATIO O \ O \ MASTER BEAM LINE ABOVE AND EXISTING SUPPORT STRUCTURE I BASEBOARD HEATER PATIO CLOSET BATHROOM / TWO C WOT \\ \ UP WINE COAT I � \ \ ELEC. PANEL STORAGE D CLOSET i ELEC. PANEL Q \ o �d LIVING \ v UNIT 640 BUILT -IN j ROOM UNIT 635 ENTRY BEDROOM O J ENTRY ENTRY FO R J _ HALL BATH I FOUR O 0 M r I SKYLIGHT ABOVE I Z • wP1 I I WP1 I DN 171 ® Q � j Z q EXIT EXIT � STAIR 1 STORAGE CLOSET1 -� -� -� STORAGE CLOSET STAIR 2 Pr z m 0 0� C p ET I I CLOSET \! I IL I H Q L22 I DN za7 - -� 0 I —_� SKYLIGHT I r Z W ATHROOM Li r ABOVE — ONE ��������� 231 0 � �� MASTER MASTER O TOILET \ �� ����� =� ;; � O J Q BEDROOM 17 246 I J Z ONE I 0 > 233 UNIT 630 0 o ENTRY 230 MASTER I Q > BATHROOM 245 :0 O Z vBASEBOARD HEATER COAT CLOSET ' J 242 I Q m I CLOSET MASTER N BASEBOARD HEATER TWO CLOSET O EXTERIOR 241 243 BEAM LINE ABOVE AND 0 PATIO DINING EXISTING SUPPORT STRUCTURE ROOM CLOSET LAUN RY DECK EX R 234 238 239 WP1 UNIT 645 TI PATIO 1 0 0 BEDROOM MASTER TWO BEDROOM 240 244 BATHROOM BASEBOARD HEATER BASEBOARD HEATER ISSUED FOR: DATE: WD BURNING UNIT TWO I FIREPLACE 630 O 1 237 ® I HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 n o OO I LIVING ROOM 235 \ \ KITCHEN EXTERIOR 236 PATIO 0 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. BASEBOARD HEATER SCALE: 1/4 "= 1'-0" REF. DRAWN: MDS PROJECT A- 1307 SHEET TITLE: EXISTING PLAN A III TOWN OF VAILO' Design Review Staff Approval By Warren Campbell at 11:24 am, May 16, 2013 TOWN OF VAR.!- Approved by the Planning & Environmental Commission By Warren Campbell at 11:24 am, May 16, 2013 EXISTING MEZZANINE LEVEL PLAN b (,HLt: 1 /4 = 1 -U.. C CV 0 v3 U V1 n U R L 6+ U Ci E y 0 U E Cll d �] L0 C3 ,a W U N sn ] MEZZANINE DN MEZZ BATH O V O 3 0 0 0 j a � 3 � M > M r Z■ J Z m LL LLIU) TM a W 0 a c j a > O j _ > O a 0 he W O _ m 2 a � rc � s ■ ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAINN: MDS PROJECT A- 1307 SHEET TITLE: EXISTING PLAN A1.03 IXIIIING HIGH WINDOW 1 EXISTING MEZZANINE LEVEL PLAN b (,HLt: 1 /4 = 1 -U.. C CV 0 v3 U V1 n U R L 6+ U Ci E y 0 U E Cll d �] L0 C3 ,a W U N sn ] MEZZANINE DN MEZZ BATH O V O 3 0 0 0 j a � 3 � M > M r Z■ J Z m LL LLIU) TM a W 0 a c j a > O j _ > O a 0 he W O _ m 2 a � rc � s ■ ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAINN: MDS PROJECT A- 1307 SHEET TITLE: EXISTING PLAN A1.03 s ■ ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAINN: MDS PROJECT A- 1307 SHEET TITLE: EXISTING PLAN A1.03 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAINN: MDS PROJECT A- 1307 SHEET TITLE: EXISTING PLAN A1.03 Approved by the 6� ' Planning & Environmental Commission TOWN OF VA I L By Warren Campbell at 11 :24 am, May 16, 2013 FIRST FLOOR GRFA CALCULATION SUMMARY: TOTAL FIRST FLOOR LEVEL COMMON SPACE SUBTRACTION 7606 SQ FT -787 SQ FT (4) RESIDENTIAL UNITS TOTAL EXTERIOR PATIO SUBTRACTION 6819 SQ FT -980 SQ FT TOTAL GRFA @ FIRST LEVEL: 5839 SQ FT GRFA CALL. SCALE: 1/8" = V -0" FIRST FLOOR Design Review Staff Approval TOWN OF By Warren Campbell at 11 :24 am, May 16, 2013 VAIL EXISTING I HR RATED SEPARATION WALLS TO BE MAINTAINED MEZZANINE FLOOR GRFA CALC. SUMMARY: TOTAL MEZZANINE FLOOR LEVEL 176 SQ FT TOTAL GRFA @ MEZZANINE LEVEL: 176 SQ FT GRFA CALC. @ MEZZ. FLOOR SCALE: 1/8" = 1' -0" L GARAGE LEVEL GRFA CALCULATION SUMMARY: TOTAL GARAGE FLOOR LEVEL COMMON SPACE SUBTRACTION 7310 SQ FT -5170 SQ FT (2) RESIDENTIAL UNITS TOTAL 43% BELOW GRADE DEDUCTION' 2140 SQ FT -920 SQ FT TOTAL GRFA @ GARAGE LEVEL: 1220 SQ FT GRFA CALC. SCALE: 1/8" = V -0" GARAGE EXISTING I HR RATED SEPARATION WALLS TO BE MAINTAINED S W E A SECOND FLOOR GRFA CALCULATION SUMMARY: TOTAL SECOND FLOOR LEVEL COMMON SPACE SUBTRACTION 7606 SQ FT -334 SQ FT (4) RESIDENTIAL UNITS TOTAL EXTERIOR PATIO SUBTRACTION 7272 SQ FT -858 SQ FT TOTAL GRFA @ SECOND LEVEL: 6414 SQ FT GRFA CALL. ( SCALE: 1/8" = 1' -0" ❑c ! SECOND FLR EXISTING I HR RATED SEPARATION WALLS TO BE MAINTAINED c� E Q N r' U 0 C 0 I; N I(D r� 1 U Z] R d7 `� 0 CV U v� ] 0 Q Q O d 3 0 0 v j a � 3 > � M M r Z■ J Z — J m li LIJ U) 7 T Z W D J a 0 J � a N > O Y to Z v W O Dj _ m DC � a � > O oC cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 �A 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/8 "= 1' -0" DRAWN. MDS PROJECT #. 1307 SHEET TITLE: GRFA SUMMARY A1.04 Design Review Staff Approval Approved by the Planning & Environmental Commission OVAIL TOWN F VI�� � � By Warren Campbell at 11:24 am, May 16, 2013 I By Warren Campbell at 11:24 am, May 16, 2013 TOWN OF c� E c� Q r N r' U 0 C 0 (D C3 U_ 7 77m' R P N L J H F E C A- U r2-" GRADE STUDY SOUTH ELEVATION GRADE STUDY EAST ELEVATION �11SCALE: 1/8" = 1' -0" A1.05 SCALE: 1/8" = 1' -0" 0 R Q P O N M L K J I H G F E D C B A J O d 0 3 v 0 j a � 3 > M M L'3 r Z■ J Z 5 J m L� 7 Lij U) T Z W G J a > vj � a to O Z Y v W O Dj m _ DC � a � > O oC JJ HH FF DD BB Z X W U S 4 GRADE STUDY NORTH ELEVATION 3 GRADE STUDY WEST ELEVATION ISSUED FOR: DATE: A1.05 SCALE: 1 /$" = 1' -0" A1.05 SCALE: 1/8" = 1' -0" HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 JJ II HH GG FF EE DD CC BB AA Z Y X W V U T S 2013 MICHAEL SUMAN ARCHITECT, LLC. C, ALL RIGHTS RESERVED. SCALE: 1/8 "= 1' -0" DRAWN: MDS BELOW GRADE DEDUCTION CALCULATION: PROJECT #: 1307 SHEET TITLE: GRFA DEDUCTION TOTAL WALL AREA @ GARAGE 3516 SO FT TOTAL WALL AREA BELOW GRADE 1512 SO FT BELOW GRADE RATIO 0.43 GRFA DEDUCTION @ GARAGE LEVEL UNITS 43% ■ Approved by the Design Review Planning & Environmental Commission Staff Approval TOWN OF VAIL I By Warren Campbell at 11:25 am, May 16, 2013 TOWN OF VAIL By Warren Campbell at 11:25 am, May 16, 2013 REF. n U I I— — __J DECK I DECK t7 R L `" U y \ ® E w U \ \ V i DUET DECK — — — — — — — — — — — U8 C) W/D DECK ` UP W ju o v - �j \ \ UNIT 635 0 L \ \ \\ ENTRY UNIT 640 ENTRY D C ?� O v J F77 J J 3 ------ - - - - -- —� - l r— ------ - - - - -- o Q > Z DN o j q / EXIT STAIR 1 STORAGE STORAGE EXIT STAIR 2 J m -4] T 0 CLOSET 1 CLOSET 2 0 p E ® \ CLOSET H DN r �I A ONOOM MASTER Q DEMO WINDOW GROUP -l� BEDROOM D O TOILET ' O p � AND PORTIONS OF �� ONE 7 \ O > EXTERIOR WALL. PREP AREA 1 � FOR NEW WINDOWS AND ���� 0 O UNIT 630 ENTRY -7 J Q ROOF DESIGN. III MASTER BATHROOM ' Z � > I; o Z ,c BASEBOARD HEATER COAT CLOSET ® W � O J DEMO EXIST. WALL PREP FOR NEW STAIR CLOSET MASTER W N BASEBOARD HEATER TO NEW MEZZANINE i TWO CLOSET l�l EXISTING J -- -- 1 UNIT 645 CLOSET LAUN RY BEDROOM MASTER SECOND FLOOR DEMO PLAN LIVING ff �� ROOM TWO BEDROOM i A2.02 SCALE: 1/4" = 1' -0" ssss� BASEBOARD HEATER BATHROOM BASEBOARD HEATER i ISSUED FOR: DATE: o WOOD BURNING TWO ' ' -- - - - - -- DENOTES ITEMS TO BE REMOVED AND /OR REPLACED FIREPLACE BOX, 0 DOOR -DEMO WALL ! HOA SUBMITTAL 4.1.13 HEARTH, AND WOOD ® FOR NEW DOOR I DEMOLITION NOTES: STORAGE TO REMAIN n O O LOCATION ' 1. CONTRACTOR TO COORDINATE ALL WORK WITH RIVA RIDGE MANAGEMENT 2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION TOV PEC VARIANCE 4.15.13 o ' 3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS - REMOVE ' DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOOR STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. 4. ANY WORK AFFECTING THE EXISTING EXTERIOR WALLS OR SEPARATION WALLS TO BE REPAIRED TO MAINTAIN NECESSARY FIRE SEPARATIONS OR WATERPROOFING DINING O a DECK DECK SYSTEMS. 5. CONTRACTOR TO NOTIFY ARCHITECT AND ENGINEERS IF MECH, PLUMBING OR ROOM KITCHEN ® O ELECTRICAL COMPONENTS OF SURROUNDING BUILDING ARE EXPOSED SO O 0 O COMPONENTS CAN BE PROPERLY RE- ENGINEERED OR RE- ROUTED AS NECESSARY. b. RECYCLE ALL FIXTURES 7. MAINTAIN ALL PAINTED CABINET DOORS FOR OWNER 8. MAINTAIN ALL REMOVED DOOR HARDWARE FOR REUSE � ARCHITECT, LLC. ALL RIGHTS RESERVED. C/ ALL MICHAEL S RESERVED. SCALE: 114" = 1'-0" REF. DRAINN: MDS PROJECT A- 1307 SHEET TITLE: DEMO PLAN A2,r Design Review Staff Approval TOWN � y' By Warren Campbell at 11:25 am, May 16, 2013 Approved by the Planning & Environmental Commission TOWN OF VAIL I By Warren Campbell at 11:25 am, May 16, 2013 ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAWN: MDS PROJECT A- 1307 SHEET TITLE: DEMO PLAN A2.03 O LLI � V O 3 0 0 0 a � 3 > � M M r Z■ J Z m LL LLIU) TM a W 0 a c j a > O j _ > O a he W 0 O m _ OC � a � � rc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAWN: MDS PROJECT A- 1307 SHEET TITLE: DEMO PLAN A2.03 Design Review Staff Approval TO i� j By Warren Campbell at 11 :25 am, May 16, 2013 EXISTING CHIMNEY TO REMAIN Approved by the Planning & Environmental Commission TOWN OF VAIL � L By Warren Campbell at 11 :25 am, May 16, 2013 ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAWN: MDS PROJECT A- 1307 SHEET TITLE: DEMO PLAN A2.04 O � � V O 3 0 0 0 a � 3 � > M M r Z■ J Z m LL LLIU) TM a W 0 a c j a > O j _ > O a he W v O m _ 2 a � � rc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 CC 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAWN: MDS PROJECT A- 1307 SHEET TITLE: DEMO PLAN A2.04 Design Review Staff Approval TOWN � By Warren Campbell at 11:25 am, May 16, 2013 Approved by the 0 ' Planning & Environmental Commission TOWN OF VA I L By Warren Campbell at 11:25 am, May 16, 2013 E 0 N 3t m Q+ U i E N Q� E } LO co i!1 r 0'` w U Ln y NEW UNIT 630 FLOOR AREA CALCULATIONS: SECOND FLOOR LEVEL 1,557 SQ. FT. MEZZANINE LEVEL 176 SO. FT. TOTAL FLOOR AREA 1,733 SQ. FT. ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 oVj UP FL 1 V �\ - - oC I I - O j I \ 30 UNIT 635 UNIT 640 O j J _ L'3 r WP1 DN q EXIT EXIT ' j ? STAIR 1 STORAGE STORAGE STAIR 2 -� � � � - CLOSET 1- Emu -� � � -� CLOSET 2 - — — -�� m �L. CLOG 0 E T ®' CLOSET 0 ' Lu y D N 247 - r N 2 ' ' z BATHROOM r — — � ONE � MASTER O J NEW LARGE 0 231 O �� EXIT �� O TOILET ' �� ����������� p J WINDOW GROUP / DOOR 246 a 2. \ o ' 0 / / UNIT 630 j 0 ENTRY WD CPT — Q 10 / 230 CPT —,—TILE / MASTER BATHROOM _ t- BEDROOM 245 UNIT 645 ONE --------- O 233 cod 0 Z Y 36' MIN. O0 WD CLOSET ® �° NEW STAIR �� 242 PROPOSED SECOND FLOOR PLAN O MEZZANINE ' NEW WINDOWS / / LEVEL Cep CPT CLOSET MASTER A2.22 SCALE: 1 /4" _ �' -Q" a � WITH A / NEW TALL CABINET °_ v TWO CLOSET > _ O WINDOW A O E TO BE DESIGNED / 241 243 PARTITION LEGEND: 0 D _ _ �l WOOD // FLOOR X -4� s�l F �� /" �'_�3/." s%° ' NEW WALL CONSTRUCTION NEW UNIT 630 FLOOR AREA CALCULATIONS: SECOND FLOOR LEVEL 1,557 SQ. FT. MEZZANINE LEVEL 176 SO. FT. TOTAL FLOOR AREA 1,733 SQ. FT. ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 2013 MICHAEL SUMAN ARCHITECT, LLC. \� ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: FLOOR PLAN A2.22 Commission Design Review Approved by the Staff Approval Planning & Environmental TOWN � By Warren Campbell at 11:25 am, May 16, 2013 ��r� � I By Warren Campbell at 11:25 am, May 16, 2013 I r--------------------- - - - - -- I r-------------------------------------------- I I I I L I I I I env I I I I I I a u I - I I —J -- ------------------------------- - - - --- - �T-------------------------------- - - - -- II � II u II E II II > z w III II a II II LO � � ° II � II 0 w U I I I I II II I I on I I I ® II II II I I I I I I II II II II I I I I I I I r — — — — — — — J II II II I I II I I I L--- - - - - - � I O I II II I I Ck V I I'I I cc J II O 14 J II I V O II II I J J I Ir - - - -- - - - - -- - - - -- - - - - -- ------------ - - - - -- I II r----------- - - - - -- - - - - -- ------------ - - - -11 -------- - - - --I I -------- - - - -�1 M Ir I II II Ir---------- II II II I II r I II II II II II I Z I I I r_____- I I I I r_____� I I I I J z I I I - - II I I II I I II I I II IL------------- I�--------- - - - -JI II - I I I 1�------------------------------------ - - - - -� � J m L� II ; 129 I I II Ir------------- i.--------- - -- --I II I I II I,I II I I 1 II-------_-----_-----_-----_-----_-----_---- I I I W I­ N L- - - - --I I I I r II / II II II II Z yI II II II II II I � � L- - - - --- - - - -- OPENTO L - - - - -- — - -� I I I I L---------- - - - - -- ------------ - - - - -J II L----------- - - - - -- ------------ i I I -------- - - - --I I a J 12 BEDROOM BELOW I I I J z NEW HIGH I I WINDOW GROUP j NEW ROOF FINISH TO MATCH EXISTING _ GRAVEL ON BUILT -UP I I I I I I W �' J 1 PROPOSED MEZZANINE PLAN ° m SCALE: 1/4" = 1' -0•, r--- - - - - -- co Q 8' -7" V.I.F. I I N J 3Y2 3 3%2 > 3 V2' I I I 4' -4/4" 3' -1 /4" - I _ 0 - I I I I 0 II 5 II = M EZZ 0 - . BATH 4 U8 LO NEW BATHROOM 303 AND FIXTURES DN ISSUED FOR: DATE: O oo I I c) GQ I I HOA SUBMITTAL 4.1.13 co TOV PEC VARIANCE 4.15.13 o II LL — NEW MEZZANINE PLAN II -------------------------------- - - - - -- ----------------------------------- LEVEL IN PLACE OF UNIT 630 EXISTING LOFT AREA o MEZZ v I I I I 302 NEW DORMER WALLS AND I I WINDOW GROUPS I I q I I 0 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1'-0" I I I I I I DRAINN: MDS L--------------------- - - - - - L--------------------------------------- - - - --� PROJECT A- 1307 I SHEET TITLE: FLOOR PLAN OVERSIZE HORIZONTAL GUTTER SECTION AND TIE TO b" DRAIN LEADER A2E23 WITH HEAT TO DAYLIGHT Approved by the Design Review Planning & Environmental Staff Approval d Commission � By Warren Campbell at 11:25 TOWN OF V am, May 16, 2013 TOWN OF By Warren Campbell at 11:25 am, May 16, 2013 VAI L - +�� F------------------- - - - - -- -- r--------- - - - - -- I I I r-------------------------------------------- I I I I I I I I I I I I env I I I I I I I I I I R s I I I I I a U E I I I 3 -- 1 I I II u I I II E 3:12 I 3:12 I I I > I I I I II II I I I I II II cc II cc I I II 0 I I W U I I I I I I I I I I I I N_ II N II II I I I I I I I I I o L--------- - - - - --J II II II I I I I II I I I --- - - - --� I II II I I II I I L--- - - - - --- I O I I II II I I Ck 11 I I cc J � o d II i v C II FEE I II I 1 J J 11 � 3 r- - - -- - - - - -- ----------- - - - - -- -------------------------------- II r 1 M I - - - - -- I I r - - - -- ---------- - - - - -- 1 1 I I I r---------- - - - - -- ------ - - - - -- I � 1 I � r I I I I I I I I I I I HEIGHT OF NEW SHED ROOF I Z IS SET BY EXISTING SHED HIGHEST POINT � r- - - --- I ___ _ _- 1 ___ _ _ - I I I I Ci J Z I I — — — — ------- - - --II I I II I I II I I II 1 L- ------- - - - - -4 --------- - - - -JI II - I I II------------------------------------- - - - - -� J m — ------------------------ - - - - -- - - - -- — -------- - - - - -- II 11----------------------------------------- LL I I I 11, I I 11 I,I I I I I I L I 1.1 I L I I I 1 11 � W H N - - - - -J - - - - -J L- - - - --1 1 I I TM II II II II II I Z W IIL - - - -- - - - - -- ------------ - - - -j1 11 IL----------------------------- ji I o a L` - - - -- - - - - -- ------------ - - - - -J II L------------ - - - - -- -------- - - - --1 0 1 J 11 Z > co 1 Z NEW ROOF FINISH TO MATCH EXISTING GRAVEL ON BUILT -UP 1 1 II I W � J J _ p I PROPOSED ROOF PLAN -- - - -' -- 1 1 --- - - - - -- A2.24 SCALE: 1/4" = 1' -0" I1 Q I "- 1 1 J II I P--------- - - = - -- I ,v I I 1, I I II II II I ISSUED FOR: DATE: 1 I 1 I I 3:12 HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 6 I I I 3:12 1 3;12 1 I — II --------------------------------------I1-------------------------------------- NEW DORMER ROOF @ UNIT I I I I 630 MEZZANINE TO MATCH I I EXISTING I I I 02013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0° DRAINN: MDS 1 I I -- L =--=---- - - - - -- L--------------------------------------- - - - --� PROJECT #: 1307 SHEET TITLE: ROOF PLAN OVERSIZE HORIZONTAL GUTTER SECTION AND TIE TO 6" DRAIN LEADER A2s24 WITH HEAT TO DAYLIGHT Design Review Staff Approval F By Warren Campbell at 11 :25 am, May 16, 2013 4 SECOND FLOOR 109'-7 3/4" E OIL FIRST FLOOR EL: 100' -0" 12 3 F_� Approved by the 6 ' Planning & Environmental Commission TOWN Of VA I L ' By Warren Campbell at 11 :26 am, May 16, 2013 BASEMENT — EL: 89' -8" E El EXISTING WEST ELEVATION SCALE 1/4" = 1' -0" EXISTING STUCCO SIDING EXISTING STONE SIDING EXISTING GRAVEL ON BUILT -UP ROOF P] EXISTING WOOD SIDING LH� 12 a 3 E 12 a 3 El DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E l � N 3t m Q+ U i E El EXISTING WEST ELEVATION SCALE 1/4" = 1' -0" EXISTING STUCCO SIDING EXISTING STONE SIDING EXISTING GRAVEL ON BUILT -UP ROOF P] EXISTING WOOD SIDING LH� 12 a 3 E 12 a 3 El 0 � � V O 3 0 0 v a � 3 > � M M r Z■ J Z J m L� LIJU) T Z yI O O j 0 g Z V J a N > O Y to Z v W O D j m DC � a � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E 0 N 3t m Q+ U i E N Q� E m C] Z7 LO co co w�° �- y Ln 0 � � V O 3 0 0 v a � 3 > � M M r Z■ J Z J m L� LIJU) T Z yI O O j 0 g Z V J a N > O Y to Z v W O D j m DC � a � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 J2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3s0l Design Review Staff Approval TOWN By Warren Campbell at 11:26 am, May 16, 2013 OF SECOND FLOOF OIL 109' -7 3/4" FIRST FLOOR EL: 100' -0" BASEMENT EL: 89' -8" 0 Approved by the Planning & Environmental Commission TOWN OF VA I L By Warren Campbell at 11 :26 am, May 16, 2013 EXISTING SOUTH ELEVATION SCALE: 1/4" = 1' -0" 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O FE cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 ElEXISTING STUCCO SIDING TOV PEC VARIANCE 4.15.13 IflEXISTING STONE SIDING IflEXISTING GRAVEL ON BUILT -UP ROOF 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3.02 E 0 N 3t m Q+ U i r� C N Q� E } LO co Lu y Ln 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O FE cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 ElEXISTING STUCCO SIDING TOV PEC VARIANCE 4.15.13 IflEXISTING STONE SIDING IflEXISTING GRAVEL ON BUILT -UP ROOF 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3.02 Design Review Staff Approval TOWN By Warren Campbell at 11 :26 am, May 16, 2013 OF VAIL OIL SECOND FLOOF 109' -7 3/4" FIRST FLOOR EL: 100' -0" BASEMENT EL: 89' -8" Approved by the Planning & Environmental Commission TOWN OF UA I L By Warren Campbell at 11 :26 am, May 16, 2013 AIMAI fll1DA AED fICC Il- AI EXISTING STUCCO SIDING TO REMAIN MEXISTING STONE SIDING TO REMAIN EXISTING ROOF FINISH TO REMAIN ¢D EXISTING WOOD SIDING TO REMAIN NEW STUCCO SIDING ❑ NEW CLASS A ROOF FINISH TO MATCH EXISTING ONEW DOOR OR WINDOW GROUP GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD - COLOR TO MATCH EXISTING 2) ALL FLASHING AND ROOF DRAINAGE SYSTEM TO MATCH EXISTING 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL EXISTING AND ROUGH OPENINGS. 5) EXTERIOR LOUVERS /VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS ABOVE ROOF SURFACE TO BE PAINTED TO MATCH ROOF FINISH 7) ALL NEW TRIM DETAILS TO MATCH EXISTING PROPOSED SOUTH ELEVATION SCALE: 1/4" = 1' -0" ERSIZE HORIZONTAL TTER SECTION AND TO 6" DRAIN LEADER H HEAT TO DAYLIGHT N SLIDING DOOR UNIT 0 � V Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m LL. LIJ y 7 T Z W D J a 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E 0 N 3t m Q+ U i E Q� E } (9j LO co _ co Lu y Ln 0 � V Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m LL. LIJ y 7 T Z W D J a 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. A3.02 Design Review Approved by the Staff Approval Planning & Environmental Commission By Warren Campbell at 11:26 am, May 16, 2013 TOWN OF VAIL �O WN O F VA I � By Warren Campbell at 11 :26 am, May 16, 2013 SECOND FLOOR 109' -7 3/4" YI FIRST FLOOR _ EL: 100' -0" 4 BASEMENT EL: 89' -8" 12 3 F_� El ❑VIII EXISTING EAST ELEVATION SCALE: 1/4" = 1' -0" EXISTING STUCCO SIDING EXISTING STONE SIDING EXISTING GRAVEL ON BUILT -UP ROOF ¢❑ EXISTING WOOD SIDING 0 E 0 � V LLI Q Q O d 3 0 0 v a � 3 > M M > r Z■ J Z 5 J m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E 0 N 3t m Q+ U i E V) N Q� u E m C] a� LO co co Lu m - y Ln 0 � V LLI Q Q O d 3 0 0 v a � 3 > M M > r Z■ J Z 5 J m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 J2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3,,03 Design Review K� Staff Approval TO VA+� ` By Warren Campbell at 11:26 am, May 16, 2013 SECOND FLOOR 109' -7 3/4" FIRST FLOOR EL: 100' -0" Approved by the 01 Planning & Environmental Commission �ri OF �� >L By Warren Campbell at 11:26 am, May 16, 2013 NEW DORMER DESIGN 12 TO MATCH EXISTING 3 � UNIT 635 DESIGN NEW ROOF TO MATCH PEAK NEW ROOF TO OF EXISTING ROOF a 2 - OVERSIZE HORIZONTAL GUTTER SECTION AND TIE TO 6" DRAIN LEADER WITH HEAT TO DAYLIGHT a M CC El II BASEMENT -� - -- EL: 89'-8" ---- - - - - -- -- EXISTING STUCCO SIDING TO REMAIN 71 EXISTING STONE SIDING TO REMAIN EXISTING ROOF FINISH TO REMAIN EXISTING WOOD SIDING TO REMAIN NEW STUCCO SIDING 6 NEW CLASS A ROOF FINISH TO MATCH EXISTING ONEW DOOR OR WINDOW GROUP GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD - COLOR TO MATCH EXISTING 2) ALL FLASHING AND ROOF DRAINAGE SYSTEM TO MATCH EXISTING 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL EXISTING AND ROUGH OPENINGS. 5) EXTERIOR LOUVERS /VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS ABOVE ROOF SURFACE TO BE PAINTED TO MATCH ROOF FINISH 7) ALL NEW TRIM DETAILS TO MATCH EXISTING PROPOSED EAST ELEVATION SCALE 1/4" = 1' -0" EXISTING SKYLIGHT TO REMAIN - TYPICAL 0 12 a 3 0 O Ck a a J 0 o d 3 0 0 0 j _ a � 3 � M M r > Z. J z m LLIU) TM a W 0 a o � Z g O j V _ _ ; N O a v he W O _ m OC � a � rc � cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E 0 � U n � i 0 R L Cn U Ci E V) 0 U_ E Cll a w 0 U w N - .0 ] �n O Ck a a J 0 o d 3 0 0 0 j _ a � 3 � M M r > Z. J z m LLIU) TM a W 0 a o � Z g O j V _ _ ; N O a v he W O _ m OC � a � rc � cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 J2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 114" = 1'-0" DRAINN: MDS PROJECT A- 1307 SHEET TITLE: PROPOSED ELEV. A3.03 Design Review Staff Approval R By Warren Campbell at 11:26 am, May 16, 2013 TOWN Of VA SECOND FL, 109' -7 3/4" FIRST FL00 EL: 100' -0" BASEMENT EL: 89' -8" Approved by the Planning & Environmental Commission TOWN OF nVAILBy Warren Campbell at 11:26 am, May 16, 2013 � I EXISTING NORTH ELEVATION SCALE 1/4" = 1' -0" 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 EXISTING STUCCO SIDING TOV PEC VARIANCE 4.15.13 EXISTING STONE SIDING aEXISTING GRAVEL ON BUILT -UP ROOF 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3.04 E 0 N 3t m Q+ U i E N Q� E } LO co Lu y Ln 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W D J Z 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 EXISTING STUCCO SIDING TOV PEC VARIANCE 4.15.13 EXISTING STONE SIDING aEXISTING GRAVEL ON BUILT -UP ROOF 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. X3.04 Design Review Staff Approval By Warren Campbell at 11 :26 am, May 16, 2013 TOWN OF VAIL" SECOND FL, 109' -7 3/4" FIRST FL00 EL: 100' -0" BASEMENT EL: 89' -8" Approved by the Planning & Environmental Commission TOWN OF VA I L By Warren Campbell at 11 :26 am, May 16, 2013 I.IC \A/ r*1r%DAACD fICCl/�AI CVICT1k1/- I IAIIT ZOC � I EXISTING STUCCO SIDING TO REMAIN EXISTING STONE SIDING TO REMAIN EXISTING ROOF FINISH TO REMAIN P] EXISTING WOOD SIDING TO REMAIN NEW STUCCO SIDING 6❑ NEW CLASS A ROOF FINISH TO MATCH EXISTING ONEW DOOR OR WINDOW GROUP GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD - COLOR TO MATCH EXISTING 2) ALL FLASHING AND ROOF DRAINAGE SYSTEM TO MATCH EXISTING 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL EXISTING AND ROUGH OPENINGS. 5) EXTERIOR LOUVERS /VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS ABOVE ROOF SURFACE TO BE PAINTED TO MATCH ROOF FINISH 7) ALL NEW TRIM DETAILS TO MATCH EXISTING PROPOSED NORTH ELEVATION SCALE: 1/4" = 1' -0" 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W G J Z > 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 E 0 N 3t m Q+ U i r� C Q� E } (9j LO co _ co Lu y Ln 0 DLLI Q Q O d 3 0 0 v j a � 3 > M M > r Z■ J Z m L� LIJ U) 7 T Z W G J Z > 0 � a > O Y to Z v W O Dj _ m DC � Q � > O F cc ISSUED FOR: DATE: HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" DRAWN: MDS PROJECT #. 1307 SHEET TITLE: PROPOSED ELEV. A3.04 Design Review Staff Approval Approved by the Planning & Environmental Commission By Warren Campbell at 11:26 am, May 16, 2013 �� Q TOWN OF VAS L � By Warren Campbell at 11:26 am, May 16, 2013 I �© o U vi n N L_ -- R s °' U I I I � E I I y � ® \ \ \ \ u E Ue \\ 0 \ \\ I 0 R co co aNU 0 \\ \\ 0 ----- \\ \ \ I \ \ `vI I 0 yIy----- \\ I ® O W V v o ED o Ll � v oac O � d \\ \\ 0 ° 0 ��_ I o > M O r 0 q EXIT EXIT J STAIR 1 STORAGE STORAGE STAIR 2 m C T � CLOSET 1 LINEN 0 CLOSET 2 0 W � u) ONE ® CLOSET 232 247 _ z r W BATHROOM) � ONE O MASTER O J 2$1 TOILET p J / 246 F(3 Z 0 > UNIT GENERAL ELECTRICAL NOTES: � 0 / / ENTRY Y F2-30-1 BATHROOM 1) NEW SMOKE DETECTOR TO BE INTERCONNECTED PER IRC CODE - HARDWIRED a > BEDROOM / 245 2) MINIMUM 50% OF NEW LIGHTING TO BE HIGH EFFICIENCY PER 2009 IECC O eo ONE / 233 / / o CLOSET © Z Lu V J 242 ELECTRICAL KEY: o m CLOSET MASTER ® PENDANT LIGHT $ SWITCH Q TWO CLOSET KP J 241 243 (4 DIRECTIONAL LIGHT KEY PAD SWITCH / / a SURFACE MOUNTED LIGHT $ MULTIPLE SWITCH D DECK El ROOM / LAUN Y F-® WALL MOUNTED SCONCE D DIMMER SWITCH 234 0 239 _ RECESSED CEILING LIGHT =@ DUPLEX RECEPTACLE / _ _ _ \� + RECESSED PINLIGHT FI GROUND FAULT DUPLEX RECEPTACLE MASTER ❑ RECESSED WALL LIGHT HALF HOT RECEPTACLE BEDROOM / 244 o CLOSET STRIP LIGHT QUAD RECEPTACLE BAT ROOMJ i \ 0 F FLUORESCENT LIGHT ® SPECIAL DEVICE OUTLET ISSUED FOR: DATE: / 237 — — — — LED STRIP LIGHTING DUPLEX FLOOR RECEPTACLE HOA SUBMITTAL 4.1.13 TOV PEC VARIANCE 4.15.13 � SPECIALTY PENDANT F--0C CATEGORY 5E CABLE BEDROOM / / \ GFI EP 0 TWO - a -o-p -p TRACK LIGHT 1-02C 2 CATEGORY 5E CABLES 240 1 DECORATIVE WALL MOUNT F ❑TV 2 RGb COAXIAL LIVING ° STAKE MOUNTED LANDSCAPE LIGHT �-❑ S STRUCTURED CABLE ROOM (2 CAT 5E & 2 RGb COAX) F2-35-1 ® PIER MOUNTED LIGHT A TELEPHONE OUTLET KITCHEN NBC QO OD SMOKE DETECTOR CAMERA 236 ®S SPEAKER WALL MOUNTED EXHAUST FAN 2013 MICHAEL SUMAN ARCHITECT, LLC. ALL RIGHTS RESERVED. ❑F BATHROOM EXHAUST FAN SCALE: 1/4 "= 1'-0" DRAWN: MDS PROJECT #: 1307 SHEET TITLE: LIGHTING PLANS SECOND FLOOR POWER PLAN �-11SCALE: 1/4" = V -0" E2sOl Design Review Staff Approval Approved by the Planning & Environmental Commission TOWN O IL By Warren Campbell at 11 :27 am, May 16, 2013 �� VAIL 1, By Warren Campbell at 11:27 am, May 16, 2013 L --------------- -------------------------------------------- I I I I env E I I n I I R s a U I I I I � � � I I I I -- — — — — — — — — — — — — — — — — — — — — — — — — — ------------ �r------------------ - - - - ------------- - - - - -J II � II u II E II II � > II II II II 'I � � (D II n 0 ii W II I O II II II ion] � I I i I ® II II II II II II I � � I II II II II II II I II LLI II ° I II a a j II j 0 14 II 3 II O V J II II J j - - - - - - - - - - - - - - - -- cq - - - - -- – – – – – – – – – – – – – – – – – – – - - I II II II II � r II II II II Z ' I– �I r- - - - IF - --1 Q 0' J Z I — I I I I II I I II I I I I J m M _– Wu) - - - - -J –- I Z Lu II IL------ ! - - - -- L ------------ - - - -�I II II �---------- L------------ - - - - -- o a J _ _ - - - -- – – – – ------------ - - - - -� II - - - - -- - 12 J II Z > GENERAL ELECTRICAL NOTES: 1) NEW SMOKE DETECTOR TO BE INTERCONNECTED PER IRC CODE - HARDWIRED > 2) MINIMUM 50% OF NEW LIGHTING TO BE HIGH EFFICIENCY PER 2009 IECC O d 4 d Z ° � ea ° ° ° a W O ° d ° ° a° °da ELECTRICAL KEY: m ° ° d a a ° . _ . e a ° I I ® PENDANT LIGHT SWITCH a N e ° ° ° ° ° ° 0 I I KP KEY PAD SWITCH DIRECTIONAL LIGHT Q J ° . a i ° ° ° °- - ° 1 _e. o d ° °. ❑O SURFACE MOUNTED LIGHT MULTIPLE SWITCH cc d. ° °a ° ° ° d ° d ° dl d ° ° a4 ° p I--0 WALL MOUNTED SCONCE $ DIMMER SWITCH - $ O ° RECESSED CEILING LIGHT DUPLEX RECEPTACLE ,Q a e ° GFI RECESSED PINLIGHT GROUND FAULT DUPLEX RECEPTACLE ° ° ° °a °e e I r I �/ —` ❑ RECESSED WALL LIGHT HALF HOT RECEPTACLE ° ° ° ° ° d I I 4n °d II CLOSET STRIP LIGHT QUAD RECEPTACLE da° l kGFI OF FLUORESCENT LIGHT ® SPECIAL DEVICE OUTLET ISSUED FOR: DATE: ° - - -- LED STRIP LIGHTING DUPLEX FLOOR RECEPTACLE HOA SUBMITTAL 4.1.13 ° / SPECIALTY PENDANT 1--0c CATEGORY 5E CABLE TOV PEC VARIANCE 4.15.13 ° a `: olz\ TRACK LIGHT I-02C 2 CATEGORY 5E CABLES �° \\ DECORATIVE WALL MOUNT I—❑TV 2 RG6 COAXIAL ° ° a ° a °° -- --------------------------- ------ - - - - -- ------------------------------------ STAKE MOUNTED LANDSCAPE LIGHT �❑S STRUCTURED CABLE ° ° ° °aa a . / UNIT 630 (2 CAT 5E & 2 RG6 COAX) I ° �/ MEZZ ® PIER MOUNTED LIGHT �\ A TELEPHONE OUTLET ° d c 302 \\ Op SMOKE DETECTOR CAMERA 1 ®s SPEAKER WALL MOUNTED EXHAUST FAN 2013 MICHAEL SUMAN ARCHITECT, LLC. C' ALL RIGHTS RESERVED. SCALE: 1/4 "= 1' -0" I I OF BATHROOM EXHAUST FAN DRAWN: MDS O PROJECT A- 1307 SHEET TITLE: LIGHTING PLANS MEZZANINE FLOOR POWER PLAN �O2SCALE: 1/4" = 1' -0" E2s 02