Loading...
HomeMy WebLinkAboutB13-0177 CUT SHEETS.pdf 4 MITSUBISHI /_ ELECTRIC MnSUM. C O O L I N G & H EATING Iff Split-ductless A/C and Heat Pumps SUBMITTAL DATA: PKA-A36KA4 & 00 WALL-MOUNTED Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES IIII • Innovative flash technology enables high heating capacity at lower outside temperatures IIII • Exhibits 100%of rated heating capacity at 5°F;90%of rated heating capacity at-4°F g p Y IIII • Quiet operation—both indoor and outdoor units I - • Automatic fan speed control Indoor Unit:PKA-A36KA4 III • Auto restart following a power outage • Self-check function—integrated diagnostics • Limited warranty:five years on parts and defects and seven years m on compressors OPTIONAL ACCESSORIES Indoor Unit Outdoor Unit:PUZ-HA36NHA4 ❑ Condensate Pump(PAC-SH84DM-E) OPERATING RANGE ❑ High-efficiency Filter(MERV 8)(PAC-SH89KF-E) I Indoor Intake Air Temp. Outdoor Intake Air Temp. Outdoor Unit Coolin g Maximum 90-F(32°C)DB,73-F(23°C)W13 115-F(46°C)DB Minimum 66°F(1900)DB,59OF(15°C)WB 0°F**(-18°C)DB ❑ M-NET Adapter(PAC-SF80MA-E) Maximum 83°F(28°C)DB 70°F(21°C)DB,59°F(15°C)WB ❑ Air Outlet Guide(PAC-SG59SG-E;two pieces are required) Heating Minimum 63-F(17°C)DB -13°F(-251C)DB,-13°F(-25"C)WB ❑ Wind Baffle(WB-PA2;two pieces are required) **With optional wind baffle accessory installed.If not installed,the minimum temperature will Controller Options be 23°F(-5°C)DB. ❑ Wireless Remote Controller Kit(MHK1)with Remote Controller Indoor Unit (MRCH1),Wireless Receiver(MIFH1),and cable(MRC1)* MCA.... . ........ ....... . ...... . ...... . ........ ..... 1 A ❑ Setback down to 50*F when used with MRCH1 Remote Fan Motor 0.57 F.L.A. ...... . . ....... . ..... . . ...... . ...... . Controller Fan Motor Output. . . ..... . . . ..... . . .... . . . .. .. . . . ...56 W ❑ Portable Controller(MCCH1;for use with Wireless Remote Airflow(Lo-Mid-Hi)...... . ...... . . ...705-810-920 Dry CFM Controller Kit(MHK1)* 635-730-830 Wet CFM ❑ Outdoor Air Sensor(MOS1;for use with Remote Controller Sound Pressure Level(Lo-Mid-Hi) ...... . . . . 43-46-49 dB(A) (MRCH1),Wireless Remote Controller Kit(MHK1)and Portable Controller(MCCH1)* *See Submittal for information on each option. DIMENSIONS I UNIT INCHES/MM ❑ Wall-mounted Wired Remote Controller(PAR-21 MAA) W 46-1/16/1,170 ❑ External Heat Adapter(CN24RELAY-KIT-CM3) D 11-5/8/295 ❑ CN24 Relay Kit(CN24RELAY-KIT-CM) H 14-3/8/365 ❑ Remote Temperature Sensor(PAC-SE41TS) ❑ i-see Sansor(PAC-SH91 MK-E) ❑ Hand-held Wireless Remote Controller(PAR-FL32MA) Weight .. . ..... . . ........ . ..... . . . .... . . .. 46 lbs./21 kg External Finish... . ....... . ...... . . ..Munsell No. 1.OY 9.2/0.2 Cooling* Field Drainpipe Size I.D. . . . ...... . . ..... . . ...... .5/8"/ 16 mm Rated Capacity..... . . ...... . ...... . . ..... . . ... 33,400 Btu/h Outdoor Unit Minimum Capacity.. . . ...... . ...... . . ..... . .... 18,000 Btu/h Compressor..... . ....... . ...... . . ...DC Inverter-driven Scroll SEER.... . . . ..... . . . ..... . . ..... . . ..... . . . ...16.2 Btu/h/W MCA.... . ....... . . ..... . . ...... . . ..... . ........ . ..... 28 Total Input.. . . ..... . . ...... . ....... . ...... . . ..... .2,790 W Fan Motor. . . .... . . ...... . . ..... . . ...... . . .. 0.4+ 0.4 F.L.A. Heating at 47°F* Sound Pressure Level Rated Capacity..... . . ...... . ....... . ..... . . ... 38,000 Btu/h Cooling . ...... . . ....... . ..... . . ...... . . ...... . . 52 dB(A) Minimum Capacity 18,000 Btu/h Heating . . ..... . . ...... . . ..... . . ...... . . ..... .. . 53 dB(A) HSPF(IV). . . . ..... . . . ..... . ....... . ..... . . . ...10.0 Btu/h/W Total Input.. . . ..... . . ...... . ...... . . ...... . . ..... .3,410 W DIMENSIONS INCHES/MM Heating at 17°F* W 37-3/8/950 Rated Capacity..... . . ..... . . ...... . . ..... . .... 25,000 Btu/h D 13+1-3/16/330+30 Rated Total Input .. . . . ..... . . ..... . . . ..... . . . .... . .3,330 W H 53-1/8/1,350 Maximum Capacity . ........ . ..... . . ...... . . ... 38,000 Btu/h Total Input. . . ...... . . ...... . ....... . ..... . . ...... .6,010 W *Rating Conditions(Cooling)-Indoor:80°F(27°C)DB/67°F(19°C)WB.Outdoor:95-F(35°C)IDS/75°F Weight .. . . ..... . . ...... . . ..... . . ...... . . . 265 lbs./120 kg 24-C)W13 External Finish.. . . . ..... . . . ..... . . . .. Munsell No.3Y 7.8/1.1 (Heating)-Indoor:70°F(21°C)DB/60°F(16°C)WB.Outdoor:47°F(8°C)DB/43°F(6°C)WB. (Heating at 17°F)-Indoor:70°F(21°C)DB/60°F(16°C)WB.Outdoor:17°F(-8°C)DB/15°F(-9°C)WB. Refrigerant Type.. . ...... . . ...... . . ..... . . ...... . ... R41 OA Refrigerant Pipe Size O.D. Heating at 5*F Gas Side...... . . ...... . ...... . . ..... . . ... 5/8"/15.88 mm Maximum Capacity . ........ ...... . . ...... . .... 38,000 Btu/h Liquid Side ... . . . ..... . . . ..... . . ..... . . .... 3/8"/9.52 mm Total Input. . ........ . ...... ....... . . ..... . ....... .6,760 W Max.Refrigerant Pipe Length ...... . ..... . . ...... . .245'/75 m Max.Refrigerant Pipe Height Difference .. . . . .... . . ..100'/30 m Electrical Requirements Connection Method ...... . ....... ...... . . ...... . . ....Flared Power Supply...... . . ..... . . ...... .208/230V, 1-Phase,60 Hz Breaker Size....... . . ..... . . ...... . . ..... . ....... . . ...30 A Voltage Indoor-Outdoor S1-S2.... . . ...... . . ..... . . ...AC 208/230V I I ER R Indoor-Outdoor S2-S3... . . . ....... . ..... . . ...... . . DC 24V Indoor-Remote Controller. . . . . . . . . . . . . . . . DC 12V:Wired Type ©2012 MITSUBISHI ELECTRIC US,INC. DIMENSIONS: 1 1 1 Top side Unit: inch (ni 16-11M6(a23.7) 17(431.7) N - C]Cl Left side ^V Right side Front side Mount board Knockout hole for left piping C �- 2-29132 A 33-21!32 55 9-V2 241 11-5/3(295) 13M6(5) A 46-1116(1170) Knockout hole for right piping Front side(Grille open) operation lamp 0EF 06T16TAN0 BY lamp Receiver Terminal blockfor Outdoor unit Terminal Llockfor power supply(option) Terminal block for m Filter hook MA-remote con troller(only PKA-A-KA models `� - -- -- -- -- -- -- Emergency operation switch m 1-3116 0 4-27!32 (cool ingl heatng) 1-318 5 17-15/32(444) Gas e (123� 2-19/32 66 18-31f32 482)(❑ uid e 61M(154) 23-1132 585 Drain hose s 9132(134) Under side Piping connection G m Refrigerant pipe,3ffl O.D.( 9.52) Liquid pipe Flared connection:3f81` T Refrigerantpipe 5B0 D (4115 88) S 1- Gas pipe Flared con necticn.5l8F leeve Through hole � Field su lied 5,8(4 16)O D 02-15116(j675) 02-15116-0 3-5/32 Drain hose �_J 075^080 Vane(auto) Lower(manual) Knockout hole forlower i in Cer�termeasuremert hole OM2(m25) 441122(LO)Boll hole Mount board Knockout hole for piping 0 qQe 754MG(0)5.1) s � M2�,�� { IndounloThpping�rewhole utline C B A 5rg(15 5)-o - o1m 1n(12.5) r 31732(25) _ _ _ _ la(lab) 1a1rs(eol 1-15132(37.5) 4 2-15132(62}} Z-5 V n z 15n8 ps7 3-7,18 87 5 3-15!18 CI00) F� - 1.6(1045) a122(nd - - _ - _ - _ -382(1%5) m N m 428132(125) �_ _ _ _ _ &1!32[771 5-1922(142) �i1 s(im 13132 13(52 7 7-9/16(192) - _ - 817732(217 2-9116(65) (1e7). ) 9-17!32(242) - 9-1132(229.5} 2-9,16(66) 11(279.5) - _ _ -_ - 1013,22(264) 11-11202) -- -- -- - ,21MCC3�.S 12 174(311) Knockout holefor N ° Required space(Indoor unit) t eft rear piping Wall hole for 2-15116k18-29f32 75x880 left rear i in Air/Net Ij Wall hole for right rear piping c Air outlet /ry Min.2(50.5) Min.2-27132(724) Min.8-21r32(220 ©2012 MITSUBISHI ELECTRIC US,INC. DIMENSIONS: 1 1 I Unit:mm<inch> 0 0 Q3 <9IEM4 <9L/BSL>OLf <ZE!£'L>9Z a0 <9R-Z—OL LL `m EY —IL-Z>99 <ZE/E-Z>ES � 2 ]fl x mm ULJU C9 Toc—M-1— 2fISZ>fZ <sascs <za6L-vLxcE E<else>6LZ <sL/e-hL9=' a 2 <ZG9-E9>o%L E O 'vEi ILII LM `a m 0000000 cr U v 0000000 rnE d Z m� .000000 ; m 0, '; v - - 1 V o a - ¢ - € E .6 A ESE E �? 0 s Z .0 Z °m r " mwoe _'.-.,v w §o OLL d 3 n°a Y <A ZiS <9L/4-LaLL S+J my�cZll-Z=£9 -��"' <E/L-Z>EL <ZE16z>rz 6wlet5r HtILl91> -v W U� w Q y 3 - LU o° ^C a 2 _ r iu 3 3 <ul ves —z— Elk E m m els-e=zs U) O m �_ 9 0 <9LIL-4>GZ <ZEI6Z>EZ 04 E Z PK LLWL <EILAEL <ZG6Z>EZ v m E a E O cc 3 v E E O 3`v' En O fin; uI - m � p <aN p �-s. 2E d �C� l.l.l m'in n E� En �.`'c lei HaW p Em °a"O1J x _a LLy LLY a W oor a MITSUBISHI ELECTRIC C O O L I N G & H E A T I N G mad CERTIFIE -I Live Better AMI Standard 210/240 US 3400 Lawrenceville Suwanee Rd �LSTEO Suwanee,GA 30024 Tele:678-376-2900•Fax:800-889-9904 Intertek Toll Free:800-433-4822(0) www.mehvac.com FORM#PKA-A30KA4/PUZ-HA36NHA4-201211 Specifications are subject to change without notice. ©2012 MITSUBISHI ELECTRIC US,INC.