HomeMy WebLinkAboutDRB130148 Plans ApprovedUNIT 16 A 1 f ! Q k J Vicinity map 1 11 = 1' -0" EXISTING PHOTOS OF EAST SIDE OF BUILDING i —a- — — -- -- 75 n o_ 00 0 N O 4 DEMOLITION Lower Level 1/4" = 1' -0" PROPOSED LOCATION OF NEW WINDOW WELL ROJECT DESCRIPTION - EXTERIOR HOA AND DRB ITEMS ­IE PROJECT OF UNIT 16, POTATO PATCH CLUB, HAS BEEN REVIEWED AND APPROVED WITH CHANGES AS DOCUMENTED ON THE DRAWING SET DATED 3 -28 -13 AS PREPARED BY VMDA. VIT IS PROPOSING THE FOLLOWING CHANGES TO THE APPROVED SUBMITTAL. FIELD VERIFY ALL EXISTING WINDOW OPENING AND COORDINATE WINDOWS SIZES. REFER TO THE SUBMITTAL FROM VMDA FOR ELEVATIONS FOR REVISION OF WINDOWS WITHIN EXISTING OPENINGS. THE WEST ELEVATION IS PROPOSED THAT IN THE LOCATION OF THE (3) STACKING UNITS THAT (2) STACKING UNITS BE USED INSTEAD. (5) INSTANTANCES THE NORTH ELEVATION IS PROPOSED THAT IN THE LOCATION OF THE (2) STACKING UNITS, THAT (1) WINDOW BE USED INSTEAD. SAME PERIMETER PROFILE THESE UNITS SHALL USE THE EXISTING /SAME ROUGH OPENINGS THE EAST ELEVATION IS PROPOSED TO HAVE A WINDOW WELL DUG OUT AND THE CONCRETE WALL CUT TO ACCEPT (1) NEW CASEMENT 2'- 11 "x3' -5" EGRESS WINDOW. NEW WINDOWS BEING PROPOSED SHALL BE REFERED TO AS 16.0.E THE NEW WINDOW WELL SHALL BE A BILCO ESCAPE WELL (A GUTTER AND DOWNSPOUT IS EXISTING IN THIS LOCATION) EXISTING GUTTER AND DOWNSPOUT NEW WINDOW WELL AND EGRESS WINDOWS 13' - 10 1/2" 00 BIL PEWELL 54 "x41 " -- MODEL #4048-541h& WINDOW WELL GRAVEL DRY WELL AT BTM OF WDW WELL CUT 0L n o U U Cn J Z �O 6" n PROPOSED EAST ELEVATION LU per Level 117'- 2" C NMain Level E81- 8" LowerLower Level 0" o" CEMENT STUCCO FINISH ON THERMAL AND AIR INFLITRATION BARRIER TO EXTEND FROM FINISH ABOVE TO BOTTOM OF WINDOW WELL. EXPOSED FOUNDATION WALLS ARE TO RECEIVE WATERPROOF MEMBRANE EXTENDING FROM FOOTING AND UP WALL AT LEAST 24" ABOVE PROPOSED FINISHED BOTTOM OF WINDOW WELL GRAVEL ELEVATION. AT THE WINDOWS, THE WALL SHEET WATERPROOFING IS TO EXTEND UP THE WALL AND UNDER THE WINDOW /OVER THE ROUGH SILL. WINDOW IS TO BE INSTALLED WITH 6" WATERPROOF WINDOW TAPE OVER ALL FLANGES. THE DRAINAGE PLANE OF THE THERMAL AND AIR INFILTRATION BARRIER ABOVE IS TO PROPERLY OVERLAP AT THE WINDOW HEAD CONDITION. BILCO SCAPEWELL 54 "x41" MODEL #4048 -54 25'- 9 1/2" 7' -10" 4' -6" 3 1/2" 2'- 11 " 3 1/2, i/�' ,, --?Or A2.1 4 le- 13'- 3 1/2" VERIFY WITH CLEARANCE TO TREE ROOTS 8' -8" 13' -6" 3' -6" 13'- 101/2" CONCRETE CUT OUT NEW WINDOW TRIM /CASING /SILL AND APPRON ARE TO MATCH THE EXISTING TYPICAL UNITS STYLE AND FINISH. EFFORT IS TO BE MADE TO PROTECT AND PRESERVE THE EXISTING WALLPAPER ON THIS WALL - 7. istv�. �r. T. �. ��ri�r.1��i�r�ur��u�i ■T.vnn�n�■ REAR PERSPECTIVE Lower Level ' 1/411 = 1' -0" PROJECT INFORMATION Project description: The unit under this phase is adding 2 windows to the north elevation and 2 windows in a new window well on the east. A new Hot Tub slab and 2 ac condensing unit are proposed. Detailed description on sheet A3.2 Location: 950 Red Sandstone Road, UNIT 16 Subdivision: Potato Patch Club Condominiums Vail, Colorado 81657 Parcel Number 2101 - 063 -06 -016 Owner: Patsy Rowe 950 Red Sandstone Drive, Potato Patch Club Condominiums, Unit 16 100 NONANTUM ST NEWTON, MA 02458 Contractor: GE Johnson Project coordinator Matt Lewis OAC Management Architect: Martin Manley Architect Jeffrey P Manley AIA PO Box 1587 Eagle, CO 81631 970.328.5151 jeff @martinmanleyarchitects.com Class of Work: Renovation Type of Construction: V -N Type of Occupancy: R2 (condominium) Sprinkler system: No Levels: 3 -story unit W J �E Z o W � U U O ILL U� U O 6 ■ W 7- a S ■ � W C I L0 M ■ Z o6 oo E N LO !Y cy� ` o X rn m° E Q0 70 Z L O U � c) OU ��m U O � � ��o O O v, 0 70 O O � a �M_ U) ry 70 ^♦ � W O O M r O r � O w 0 � W LU 2 O tD N a) r H N � C U W -O D z O o (A a �L v �' W 0 0 Z M r O r � O � � M r � W LU 2 O tD N a) r H N � C U W -O D